HP ProLiant 2500 Compaq ProLiant 2500 Family of Servers Maintenance and Servic - Page 115
Mass Storage for Duplexed Hot-Pluggable, Models, Mass Storage for Non-Hot-Pluggable Models
View all HP ProLiant 2500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 115 highlights
4-6 Switch and Jumper Information Mass Storage for Duplexed Hot-Pluggable Models Table 4-4 shows the jumper settings for each SCSI ID and its recommended drive bay. Figure 4-3 shows the physical locations of jumpers ID2, ID1, and ID0 on supported options. Table 4-4 Jumper Settings for SCSI ID Bit 2 Bit 1 Bit 0 Device in Drive Bay SCSI ID ID2 ID1 ID0 5 5 ON OFF ON 4 4 ON OFF OFF NOTE: SCSI IDs for bays 0-3 are preset to 0-3 respectively. No two devices can have the same SCSI ID. Mass Storage for Non-Hot-Pluggable Models The Integrated Wide-Ultra SCSI Controller requires that a SCSI ID be set for each SCSI device. The SCSI ID is set by jumpers ID2, ID1, and ID0 located on each SCSI device. Table 4-5 shows the jumper settings for each SCSI ID and its recommended drive bay. Figure 4-3 shows the physical locations of jumpers ID2, ID1, and ID0 on supported options. Table 4-5 Jumper Settings for SCSI ID Bit 2 Bit 1 Bit 0 Device in Drive Bay SCSI ID ID2 ID1 ID0 5 5 ON OFF ON 4 4 ON OFF OFF 3 3 OFF ON ON 2 2 OFF ON OFF 1 1 OFF OFF ON 0 0 OFF OFF OFF NOTE: No two devices can have the same SCSI ID.