HP ProLiant 2500 Compaq ProLiant 2500 Family of Servers Maintenance and Servic - Page 61
System Unit Error, 40X-Parallel Port X
View all HP ProLiant 2500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 61 highlights
3-9 POST Error Messages Continued Error Code Beeps Probable Source of Problem 304-Keyboard or None Keyboard, keyboard System Unit Error cable, or system board failure. 40X-Parallel Port X Address Assignment Conflict 402-Monochrome Adapter Failure 2S 1L,2S 501-Display Adapter Failure 601-Diskette Controller Error 1L,2S None Both external and internal ports are assigned to parallel port X. Monochrome display controller. Video display controller. Diskette controller circuitry failure. 605-Diskette Drive 2S Type Error Mismatch in drive type. 702-A coprocessor has been detected that was not reported by CMOS. 703-CMOS reports a coprocessor that has not been detected None 2S Installed coprocessor not configured. Coprocessor or configuration error. Action 1. Make sure the keyboard is attached. 2. Run Diagnostics to determine which is in error. 3. Replace the part indicated. Run the System Configuration Utility. Replace the monochrome display controller. Replace the video board. 1. Make sure the diskette drive cables are attached. 2. Replace the diskette drive and/or cable. 3. Replace the system board. Run the System Configuration Utility to set diskette type correctly. Run the System Configuration Utility and correct. 1. Run the System Configuration Utility and correct. 2. Replace the coprocessor. Compaq ProLiant 2500 Family of Servers Maintenance and Service Guide