3-13 POST Error Messages Continued Error Code Beeps Probable Source of Problem 1773-Primary Fixed None Fixed disk drive error. Disk Port Assignment Conflict 1776-Drive Array - None External and internal SCSI Port SCSI drives are both Termination Error configured to Port 1. 1777-Drive Array None Cooling fan failure, Error internal temperature alert or open cover. 1778-Drive Array None This message appears resuming whenever a controller Automatic Data reset or power cycle Recovery process occurs while Automatic Data Recovery is in progress. 1779-Drive Array None Intermittent drive Controller detects failure and/or possible replacement drives loss of data. 1780-Disk 0 Failure None Hard drive/format error. 1781-Disk 1 Failure None Hard drive/format error Action Run the System Configuration Utility and correct. Re-configure drives. Inspect for cooling fan failure or open cover. No action necessary. If this message appears and drive X has not been replaced, this indicates an intermittent drive failure. This message also appears once immediately following drive replacement whenever data must be restored from backup. Run Diagnostics. Replace failed assembly as indicated or contact your service provider. Run Diagnostics. Replace failed assembly as indicated or contact your service provider. Compaq ProLiant 2500 Family of Servers Maintenance and Service Guide