HP ProLiant 2500 Compaq ProLiant 2500 Family of Servers Maintenance and Servic - Page 73
Drive Array - Drives, Accelerator Data Loss.
View all HP ProLiant 2500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 73 highlights
3-21 POST Error Messages Continued Error Code Beeps 1799-Drive Array - Drive(s) Disabled due to Array Accelerator Data Loss. Select "F1" to continue with logical drives disabled. Select "F2" to accept data loss and to reenable logical drives. None 2L,2S (Run System Configuration Utility = "F10" key) No keyboard present Warning - Move bridge card in slot x to available slot 4, 5, 6 (x = 1, 2, or 3) (RESUME = "F1" KEY) None None None None Probable Source of Problem Volume failed due to loss of data in posted-writes memory. Power is cycled. Temperature too hot. Processor fan not installed or spinning. A configuration error occurred during POST. None. Bridge card detected in slot 1, 2, or 3. As indicated to continue. Action Press F1 to continue with logical drives disabled or F2 to accept data loss and re-enable logical drive. Check fans. Press F10 to run System Configuration Utility. Move bridge card to slot 4, 5, or 6. Press the F1 key. Compaq ProLiant 2500 Family of Servers Maintenance and Service Guide