HP ProLiant 2500 Compaq ProLiant 2500 Family of Servers Maintenance and Servic - Page 76
Memory Test Error Codes, Table 3-2, Primary Processor Test Error Codes
View all HP ProLiant 2500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 76 highlights
3-24 Diagnostic Tools Table 3-2 Primary Processor Test Error Codes Continued Error Code Description Recommended Action 199-xx Installed devices test failed 1. Check the system configuration and retest. 2. Verify cable connections and retest. 3. Check switch and/or jumper settings and retest. 4. Run the Configuration utility and retest. 5. Replace the processor board and retest. 6. Replace the system board and retest. Error Code 200-xx 201-xx 202-xx 203-xx 204-xx 205-xx 206-xx 210-xx Table 3-3 Memory Test Error Codes Description Recommended Action Invalid memory configuration Reinsert memory modules in correct location and retest. Memory machine ID test failed The following steps apply to error Memory system ROM checksum failed codes 201-xx and 202-xx: 1. Replace the system ROM and retest. 2. Replace the processor board and retest. 3. Replace the memory expansion board and retest. Memory write/read test failed Memory address test failed Walking I/O test failed Increment pattern test failed Random pattern test failed The following steps apply to error codes 203-xx through 210-xx: 1. Replace the memory module and retest. 2. Replace the processor board and retest. 3. Replace the memory expansion board and retest.