HP ProLiant 2500 Compaq ProLiant 2500 Family of Servers Maintenance and Servic - Page 91
Battery pack, below reference voltage
View all HP ProLiant 2500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 91 highlights
3-39 Accelerator status: Temporarily disabled The array accelerator board has been temporarily disabled. Check the Disable Code field. Accelerator status: Unrecognized status A status returned from the array accelerator board that DAAD does not recognize. Call your Authorized Compaq Reseller for the latest copy of DAAD. Accelerator status: Valid data found at reset Valid data was found in the posted write memory at re-initialization. The data will be flushed to disk. This is not an error or data loss condition. No action needs to be taken. Accelerator status: Warranty alert A catastrophic problem has occurred with the array accelerator board. Refer to the other messages on the Diagnostics screen for the exact meaning of this message. Replace the array accelerator board. Battery pack X below reference voltage The indicated battery pack is below the required voltage levels. Allow sufficient time for the batteries to recharge (36 hours). If the batteries have not recharged after 36 hours, replace the battery pack. Battery X not fully charged The battery is not fully charged. If 75% of the batteries present are fully charged, the array accelerator is fully operational. If more than 75% of the batteries are not fully charged, allow 36 hours to recharge them. Board not attached The array controller board has been configured for use with an array accelerator board, but one is currently not attached. Locate the original array accelerator board and attach it to the array controller board. Compaq ProLiant 2500 Family of Servers Maintenance and Service Guide