- HP ProLiant BL495c | HP BladeSystem c-Class SAN connectivity technology brief - Page 1
, 3rd edition Abstract...2 Introduction...2 HP BladeSystem c-Class architecture ...2 c-Class server FC interconnect options 4 FC Host Bus Adapters ...4 c-Class FC SAN interconnect modules 5 Port mapping of server blade FC HBA mezzanine cards 7 FC SAN connectivity ...11 Port redundancy strategies - HP ProLiant BL495c | HP BladeSystem c-Class SAN connectivity technology brief - Page 2
Abstract Storage Area Network (SAN) connectivity with HP BladeSystem c-Class server blades is distinctly different from SAN connectivity with other HP ProLiant servers. This paper describes the hardware and software required to connect BladeSystem c-Class server blades to SANs1 using Fibre Channel ( - HP ProLiant BL495c | HP BladeSystem c-Class SAN connectivity technology brief - Page 3
stand-alone tower. The c3000 enclosure supports the same c-Class server blades and interconnects used in the c7000 enclosure. Figure 2. Architecture of the HP BladeSystem c3000 enclosure Tower - front Rack-mount - front Storage blade Insight Display Half-height server blade Rack mount - rear 6U - HP ProLiant BL495c | HP BladeSystem c-Class SAN connectivity technology brief - Page 4
between the driver and firmware and reduces the number of software components that administrators must mange. The Emulex and QLogic 4-Gb cards are compatible with all ProLiant c-Class and Integrity server blades. The Emulex and QLogic 8-Gb cards are compatible with ProLiant G6 server models but - HP ProLiant BL495c | HP BladeSystem c-Class SAN connectivity technology brief - Page 5
-performance, auto-negotiating external SFP ports. The modules allow moving or replacing server blades efficiently without involving SAN administrators. Each module provides 16 internal ports for connections with server blade HBAs and four or eight external ports (depending on model) for connections - HP ProLiant BL495c | HP BladeSystem c-Class SAN connectivity technology brief - Page 6
server connectivity within each module is fault tolerant. The HP Virtual Connect Ethernet Module (required when HP Virtual Connect FC Modules are used) can manage server . The Brocade 8-Gb SAN Switch is available in the following configurations: • The12-port model supports any combination of internal - HP ProLiant BL495c | HP BladeSystem c-Class SAN connectivity technology brief - Page 7
fabric performance. • Virtual SAN (VSAN) support - Up to 16 VSANs per switch can be managed as independent fabrics for more efficiency and lower cost through shared use, and for increased security through isolation of devices on the same physical SAN. Port mapping of server blade FC HBA mezzanine - HP ProLiant BL495c | HP BladeSystem c-Class SAN connectivity technology brief - Page 8
of the c7000 enclosure. In practice, server blades can support a mix of mezzanine cards of different server blade include a mezzanine card if a connection to a fabric is not required by a server. Technical information for c-Class enclosures is available at http://h71028.www7.hp.com/enterprise/cache - HP ProLiant BL495c | HP BladeSystem c-Class SAN connectivity technology brief - Page 9
In practice, server blades can support a mix of HP c3000 Enclosure Half-height server blade (one of up to 8) Slot 2 Slot 1 NIC 1 NIC 2 FC HBA mezz card 1 Port 1 Port 2 FC HBA mezz card 2 Port 1 Port 2 Midplane Bay 2 Bay 1 Ethernet module Pass-thru, or SAN switch Full-height server blade - HP ProLiant BL495c | HP BladeSystem c-Class SAN connectivity technology brief - Page 10
components in the enclosure. When the system is booted, the Onboard Administrator of the enclosure checks the configuration of server blades and interconnect modules for errors. The system status, including interconnect data, appears on the HP Insight Display at the front of the enclosure. Figure - HP ProLiant BL495c | HP BladeSystem c-Class SAN connectivity technology brief - Page 11
in the c7000 enclosure for full-height and half-height server blades connecting to a SAN through FC interconnect modules. Figure 8. Server blade-to-SAN connectivity for the HP c7000 Enclosure, dimensional view FC interconnect module in even-numbered bay SAN FC HBA mezzanine card (1x card) FC - HP ProLiant BL495c | HP BladeSystem c-Class SAN connectivity technology brief - Page 12
BladeSystem c7000 Enclosure is determined by the number of FC ports per server blade (Table 2). HP recommends the use of redundant SANs. Redundancy for FC HBA mezzanine cards requires the following configurations: • One or more server blades with a dual-port FC HBA card require two FC interconnect - HP ProLiant BL495c | HP BladeSystem c-Class SAN connectivity technology brief - Page 13
number of the server blades in the enclosure will ever require a SAN connection. Each pass-thru module provides dedicated paths between up to 16 server blades and an equal number of SAN switch ports or SAN target 1-16 to server blades (devices 1-8, port 2) (devices 9-16, port 2)* HP pass-thru - HP ProLiant BL495c | HP BladeSystem c-Class SAN connectivity technology brief - Page 14
of server blade connectivity, depending on the number of VC-FC module uplink ports connected to the Fabric SAN switches. The user may select other mappings as described in the HP Virtual Connect Manager Command Line Interface Version 2.10 Users Guide available at http://h18004.www1.hp.com - HP ProLiant BL495c | HP BladeSystem c-Class SAN connectivity technology brief - Page 15
. Always consult product-specific information to determine supported configurations. HP software for server deployment/SAN connectivity The HP ProLiant Essentials Rapid Deployment Pack (RDP) simplifies the installation, configuration, and deployment of high volumes of server blades via a drag-and - HP ProLiant BL495c | HP BladeSystem c-Class SAN connectivity technology brief - Page 16
description HP StorageWorks SAN Design Guide HP SAN Visibility Software Utility HP SAN Designer Software Utility Care Pack (for hardware and software information and for orderable part numbers) Rapid Deployment Pack Knowledge Base HP BladeSystem c-Class technical documentation HP Virtual Connect
HP BladeSystem c-Class SAN connectivity
technology brief, 3
rd
edition
Abstract
..............................................................................................................................................
2
Introduction
.........................................................................................................................................
2
HP BladeSystem c-Class architecture
......................................................................................................
2
c-Class server FC interconnect options
................................................................................................
4
FC Host Bus Adapters
...................................................................................................................
4
c-Class FC SAN interconnect modules
.............................................................................................
5
Port mapping of server blade FC HBA mezzanine cards
.......................................................................
7
FC SAN connectivity
..........................................................................................................................
11
Port redundancy strategies
..............................................................................................................
12
Selecting interconnect module types
.................................................................................................
13
Connecting with pass-thru modules
...............................................................................................
13
Connecting with HP Virtual Connect Fibre Channel modules
............................................................
14
Connecting with SAN switches
....................................................................................................
14
Interconnect bay loading summary
...............................................................................................
15
HP software for server deployment/SAN connectivity
.............................................................................
15
Conclusion
........................................................................................................................................
16
For more information
..........................................................................................................................
16
Call to action
....................................................................................................................................
16