HP Smart Array B110i SATA RAID Controller User Guide Part Number 531480-003 March 2010 (Third Edition) - HP ProLiant DL160se | HP Smart Array B110i SATA RAID Controller User Guide - Page 2
of Microsoft Corporation. Intended audience This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels. - HP ProLiant DL160se | HP Smart Array B110i SATA RAID Controller User Guide - Page 3
HP ProLiant 100 Series servers ...5 HP ProLiant 300 Series servers ...5 Configuring an array...6 Option ROM Configuration for Arrays 6 Array Configuration Utility ...7 Installing the HP Smart Array controller-Linux 21 Diagnosing array problems...22 Diagnostic tools ...22 Electrostatic discharge - HP ProLiant DL160se | HP Smart Array B110i SATA RAID Controller User Guide - Page 4
Index...26 - HP ProLiant DL160se | HP Smart Array B110i SATA RAID Controller User Guide - Page 5
default and must be enabled in RBSU. For more information on RBSU, see the HP ROM-Based Setup Utility User Guide on the Documentation CD or the HP website (http://www.hp.com/support/smartstart/documentation). HP ProLiant 100 Series servers To enable the controller and set boot order: 1. Power up the - HP ProLiant DL160se | HP Smart Array B110i SATA RAID Controller User Guide - Page 6
the default configurations that ORCA uses, refer to the HP ROM-Based Setup Utility User Guide on the Documentation CD. The HP Smart Array B110i SATA RAID Controller does not support ORCA CLI. To create a logical drive using ORCA: 1. Power up the server. 2. When prompted during the start-up sequence - HP ProLiant DL160se | HP Smart Array B110i SATA RAID Controller User Guide - Page 7
remote service • Supports assignment servers, see the README.TXT file for additional browser and support information. For more information, refer to the Configuring Arrays on HP Smart Array Controllers Reference Guide on the Documentation CD or the HP website (http://www.hp.com). Installing the HP - HP ProLiant DL160se | HP Smart Array B110i SATA RAID Controller User Guide - Page 8
key, be sure that hard drives are installed. For more information on installing hard drives, see the server user guide. To obtain the license key, see the entitlement certificate included with the HP Hot Plug Advanced Pack. Depending on the method of delivery, the certificate is provided either in - HP ProLiant DL160se | HP Smart Array B110i SATA RAID Controller User Guide - Page 9
in the space provided. ORCA issues a notification after the license key activates successfully. Installing a license key with ACU To install a license key: 1. Power down the server, if necessary. 2. Power up the server. Enabling and configuring the controller 9 - HP ProLiant DL160se | HP Smart Array B110i SATA RAID Controller User Guide - Page 10
3. Open ACU. 4. Select a controller from the Controller/Device menu. The System Status, Systems And Devices, and Available Tasks panels appear. 5. In the Available Tasks panel, click Manage License Keys. IMPORTANT: If no hard drives are installed, then this option does not appear. Specific license - HP ProLiant DL160se | HP Smart Array B110i SATA RAID Controller User Guide - Page 11
hp.com/support). When prompted for product information, enter the appropriate server model name. Windows operating systems For Windows operating systems, the device drivers install automatically with the assisted installation option on the Easy Set-up CD or SmartStart CD. For manual instructions - HP ProLiant DL160se | HP Smart Array B110i SATA RAID Controller User Guide - Page 12
CD or the Easy Set-up CD. The procedure is provided with the agents. To download the latest versions of the CDs, see the HP website: • SmartStart CD (http://h18013.www1.hp.com/products/servers/management/smartstart/documentation.html?jumpi d=hpr_R1002_USEN). • Easy Set-up CD (http://h18013.www1 - HP ProLiant DL160se | HP Smart Array B110i SATA RAID Controller User Guide - Page 13
or earlier). • ACU lists all failed drives (on systems supported by ACU v8.28.13.0 or later). For additional information about diagnosing hard drive problems, see the HP ProLiant Servers Troubleshooting Guide on the HP website (http://www.hp.com/go/bizsupport). Effects of a hard drive failure When - HP ProLiant DL160se | HP Smart Array B110i SATA RAID Controller User Guide - Page 14
a drive in an array fails while another drive in the array is being rebuilt. Compromised fault tolerance can also be caused by problems unrelated to drives. In such cases, replacing the physical drives is not required. Recovering from compromised fault tolerance If fault tolerance is compromised - HP ProLiant DL160se | HP Smart Array B110i SATA RAID Controller User Guide - Page 15
. The controller immediately fails drives that have insufficient capacity. To replace more drives in an array than the fault tolerance method can support, follow the previous guidelines for replacing several drives simultaneously. Wait until rebuild is complete, as indicated by ACU/ACU-CLI, before - HP ProLiant DL160se | HP Smart Array B110i SATA RAID Controller User Guide - Page 16
logical drive. 2. Restore data from the backup. The replacement drive has failed. Verify that the replacement drive has the correct capacity and is a supported model. If these factors are not the cause of the failure, use a different drive as the replacement. Another drive in the array has failed - HP ProLiant DL160se | HP Smart Array B110i SATA RAID Controller User Guide - Page 17
as a replacement for a failed drive. • If moving the drives to a different server, confirm that the new server has the latest system ROM and drivers. For more information, see the HP website (http://www.hp.com/go/support). Observe the following conditions for moving an array to another controller - HP ProLiant DL160se | HP Smart Array B110i SATA RAID Controller User Guide - Page 18
hard drives on the new controller does not exceed the maximum number of supported hard drives for that controller model and firmware version. Adding drives You arrays (on page 17)." If the HP Hot Plug Advanced Pack is not installed, you must reset the server after the hard drives are added - HP ProLiant DL160se | HP Smart Array B110i SATA RAID Controller User Guide - Page 19
see the server user guide or the HP website (http://www.hp.com/go/support): 1. When prompted for product information, enter the Smart Array controller model number in the product field. 2. Select Download drivers and software. 3. Select the appropriate operating system. 4. Download the HP ProLiant - HP ProLiant DL160se | HP Smart Array B110i SATA RAID Controller User Guide - Page 20
the System Support Software menu, select the current operating system. 2. Select Driver - storage controller. 3. Download the HP ProLiant Smart Array SAS instructions to migrate hard drives from the embedded HP Smart Array B110i SATA RAID controller to an optional Smart Array controller in a server - HP ProLiant DL160se | HP Smart Array B110i SATA RAID Controller User Guide - Page 21
Download the latest Smart Array hpahcisr driver from the HP website (http://www.hp.com/go/support): a. When prompted for product information, enter the complete the migration to the Smart Array controller: 1. Power down the server. 2. Remove the access panel. 3. Remove components and cables as - HP ProLiant DL160se | HP Smart Array B110i SATA RAID Controller User Guide - Page 22
and also on the HP website (http://www.hp.com/support). When prompted for product information, enter the server model name. For more information about the meanings of the various ADU error messages, see the HP ProLiant Servers Troubleshooting Guide. • Event Notification Service This utility reports - HP ProLiant DL160se | HP Smart Array B110i SATA RAID Controller User Guide - Page 23
workstations. Wear the straps on both feet when standing on conductive floors or dissipating floor mats. • Use conductive field service tools. • Use a portable field service kit with a folding static-dissipating work mat. If you do not have any of the suggested equipment for proper grounding - HP ProLiant DL160se | HP Smart Array B110i SATA RAID Controller User Guide - Page 24
authorized HP Partner, or their agents. For more information about battery replacement or proper disposal, contact an authorized reseller or an authorized service provider. Taiwan battery recycling notice The Taiwan EPA requires dry battery manufacturing or importing firms in accordance with Article - HP ProLiant DL160se | HP Smart Array B110i SATA RAID Controller User Guide - Page 25
IML Integrated Management Log ORCA Option ROM Configuration for Arrays POST Power-On Self Test RBSU ROM-Based Setup Utility SIM Systems Insight Manager SMHP HP System Management Homepage Acronyms and abbreviations 25 - HP ProLiant DL160se | HP Smart Array B110i SATA RAID Controller User Guide - Page 26
effects of 13 hard drive, failure of 13 hard drive, replacing 15 hard drives, adding 18 hard drives, moving 17 HP Insight Diagnostics 22 HP SIM 11, 13 HP Systems Insight Manager 11, 13 I Insight Diagnostics 22 installing device drivers 11 installing Management Agents 11 L license key 7, 8, 9 logical - HP ProLiant DL160se | HP Smart Array B110i SATA RAID Controller User Guide - Page 27