HP ProLiant DL288 ISS Technology Update, Volume 7, Number 8

HP ProLiant DL288 Manual

HP ProLiant DL288 manual content summary:

  • HP ProLiant DL288 | ISS Technology Update, Volume 7, Number 8 - Page 1
    FAQs ― Frequently asked questions about HP UPS Management Module 1 Count on the number of CPU cores increasing 2 Optimizing the performance of multi-core processors 3 Meet the Expert - Kim Sides ...4 Common SM CLP scripting commands for ProLiant server management 5 Recently published industry
  • HP ProLiant DL288 | ISS Technology Update, Volume 7, Number 8 - Page 2
    1-1. Power use and heat dissipation increase exponentially with frequency (left), so after 2004, processor vendors began limiting the frequency (right) and increasing the number of cores per chip. What determines the number of CPU cores offered in HP ProLiant servers? HP ProLiant servers include
  • HP ProLiant DL288 | ISS Technology Update, Volume 7, Number 8 - Page 3
    trend to increase the number of cores per chip is irreversible because single-core CPUs use more power to achieve the performance levels HP BladeSystem ProLiant server blades and ProLiant servers" technology brief URL http://h20000.www2.hp.com/bc/docs/support/SupportManual/c 01518167/c01518167.pdf
  • HP ProLiant DL288 | ISS Technology Update, Volume 7, Number 8 - Page 4
    class, I realized how mathematics can be used to solve real physical problems, so I decided to be an electrical engineer. Name: Kim Sides Title: Master Technologist - TGS ESS ISS Shared Engineering Services Years at HP: 20 University/Degree • Louisiana State University: BSEE 1979 • University of
  • HP ProLiant DL288 | ISS Technology Update, Volume 7, Number 8 - Page 5
    If the server is on, the "stop system1" command issues a virtual power button press. This event is normally intercepted by the OS ACPI support to initiate a graceful shutdown. It may be ignored if the OS is configured to ignore graceful shutdown requests, if the OS is hung up, or if an OS driver is
  • HP ProLiant DL288 | ISS Technology Update, Volume 7, Number 8 - Page 6
    ISS Technology Update status=0 status_tag=COMMAND COMPLETED Server power off. hpiLO-> Volume 7, Number 8 Power cycle the server The "reset system1" command, as shown below, performs a reset by power cycling the server, regardless of the OS state. C:\putty>plink -ssh -l admin -pw password
  • HP ProLiant DL288 | ISS Technology Update, Volume 7, Number 8 - Page 7
    (RC1) on HP ProLiant servers" integration note "Power Capping for ProLiant Servers" technology brief "Technologies for HP ProLiant 100-series servers" technology brief 2nd edition URL http://h20000.www2.hp.com/bc/docs/support/SupportManual/ c00814176/c00814176.pdf http://h20000.www2.hp.com/bc/docs
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

ISS Technology Update
Volume 7, Number 8
Keeping you informed of the latest ISS technology
FAQs
Frequently asked questions about HP UPS Management Module
................................................
1
Count on the number of CPU cores increasing
..........................................................................................
2
Optimizing the performance of multi-core processors
...............................................................................
3
Meet the Expert — Kim Sides
...................................................................................................................
4
Common SM CLP scripting commands for ProLiant server management
...................................................
5
Recently published industry standard server technology communications
................................................
7
Contact us
...............................................................................................................................................
7
FAQs
Frequently asked questions about HP UPS Management Module
Newsletter staff recently received questions from the field regarding a previous newsletter article on HP UPS Management
Module (HPMM) (refer to ISS Technology Update Volume 6, Number 8). Since other customers may be experiencing the same
issues, this brief article will present those questions.
HP technical staff has provided the answers.
FAQs
Question #1________________________________________________________________________________
Q.
Is there a version of the HP UPS Management Agent available for customers running operating system ESX 3.0.x that will
provide an automatic shutdown solution when the uninterruptible power supply (UPS) runs out of power? We found
compatibility information online for VMware 2.5.x, but not specifically for 3.0.x.
A.
Technically, the current HPMM Power Protection Agent should work with VMware 2.5.x or ESX 3.0.x. The only difference is
that for ESX 3.0.x there is a shutdown option. If this option is not set correctly, when the server is rebooted, the user will
receive an error message at the login screen because the server was not shut down gracefully.
Question #2________________________________________________________________________________
Q.
From where can the agent be downloaded, either internally or externally?
We can find Windows, HP-UX, and Linux
versions online externally, but none for ESX (even version 2.5.4).
A.
VMware is based on Linux; the Linux agent is available for download at