- HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 1
X5500 Network Storage Gateway for Linux setup guide This guide provides information about setting up the HP StorageWorks X5500 Network Storage Gateway for Linux (formerly known as HP Scalable NAS Clustered Gateway). This guide is intended for administrators who will be performing the setup - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 2
L.P. Confidential computer software. Valid license from HP required for possession, use or copying. HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 3
information 5 Hardware configuration limits ...5 Supported HBA drivers ...5 Server requirements ...6 Network configuration requirements 6 Cluster SAN configuration guidelines 6 I/O scheduler policies ...7 2 Setting up physical connectivity 9 Setting up the HP X5500 Storage Gateway for Linux - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 4
image the cluster node ...39 5 Support and other resources 41 HP technical support ...41 Subscription service ...41 HP websites ...41 Documentation feedback ...41 ...46 Format of the fc_pcitable file 46 QLogic HBA drivers ...47 Unloading drivers ...47 C Configure the cluster from the command line - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 5
with HP X5500 Storage Gateway for Linux as they become available from the vendors. Check the compatibility matrix on the HP web site for the supported HBA driver versions before upgrading to a newer driver from your HBA vendor. HP StorageWorks X5500 Network Storage Gateway for Linux setup guide 5 - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 6
only for VLAN tagging. • HP X5500 Storage Gateway for Linux does not support multiple NICs connected to the same subnet without the use of bonding or teaming. • The network topology should be symmetrical; each server in the cluster should be connected to the same set of networks. • The following - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 7
guide for some sample cluster configurations that include this feature. • Disk Power Management must be disabled on any Windows systems that have access to the SAN storage. NOTE: You can attach a cluster server to other SANs that are not under HP requests according to specific priority policies. - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 8
8 Configuration information - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 9
Storage Gateway for Linux (HP X5500 Storage Gateway for Linux) server. Setting up the HP X5500 Storage Gateway for Linux Before attempting to power on the nodes on an HP X5500 Storage Gateway for Linux solution, there is some required hardware setup. The HP support specialist who installs your - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 10
-in NIC port 2 12. Built-in NIC port 1 Networks used with HP X5500 Storage Gateway for Linux should be configured as follows: • Each network be set on each network interface: Broadcast, Multicast, Up, Running. Each server has five Gigabit Ethernet connections that are to be used for data (NFS) - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 11
The iLO plays an integral part in the HP X5500 Storage Gateway for Linux solution. It is used to restart a server in the cluster if the server is not adhering to the rules of cluster guidelines on page 6 for more information. HP StorageWorks X5500 Network Storage Gateway for Linux setup guide 11 - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 12
12 Setting up physical connectivity - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 13
instructions Supported operating systems and kernels HP X5500 Storage Gateway and FS Option for Linux are supported on SuSE Linux Enterprise Server 10 Service Pack 2. The following operating system versions and kernels are supported. HP StorageWorks X5500 Network Storage Gateway for Linux setup guide - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 14
SuSE Linux Enterprise Server 10, Service Pack 2, 64-bit SuSE Linux Enterprise Server 10, Service Pack 2, 64-bit Kernel 2.6.16.60-0.21 2.6.16.60-0.37_f594963d HP X5500 Storage Gateway for Linux provides binary kernels for SLES10 SP2. These kernels include the vendor patches and HP X5500 Storage - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 15
the HP Pre-Planning Worksheet with your HP service expert. This process is part of the HP installation service associated with this product. Your HP Power on each node and configure the Configure the iLO card at boot-This is required for the iLO card. server-based fencing part of the solution. HP - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 16
not used as a primary intra-cluster communication channel. Complete the configuration. Export the configuration to the other servers, test the fencing configuration if necessary, and start HP X5500 Storage Gateway for Linux. Perform post setup tasks. See the chapter Post-Setup procedures on page - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 17
has been specifically crafted to guide you through the required steps. • Password for the System Administrator 'root'-Enter a root password. • Hostname-Enter the server's hostname and domain name. • Network Configuration • Firewall-In the Service Start box, select either When booting or Manually - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 18
appear on a separate line with its real IP address, as in the following example. Be sure to move the server name to its own line in the /etc/hosts file on each server. HP recommends that you make entries for both public and private IP addresses in the following format: • Routing-Enter a gateway - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 19
HP X5500 Storage Gateway for Linux release notes. The HP X5500 Storage Gateway for Linux release notes can be found on the HP website at www.hp , HP recommends /opt/hp/hpmouse support Linux Device Mapper Multipath can be used to provide multipath support for HP X5500 Storage Gateway for Linux. For HP - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 20
should be present in this zone. When certain problems occur on a server (for example, hardware problems or the loss of cluster network communications) and the server ceases to effectively coordinate and communicate with other servers in the cluster, HP X5500 Storage Gateway for Linux must remove the - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 21
fabric. • Web management-based fencing (also called "server-based fencing"): HP X5500 Storage Gateway for Linux uses remote management hardware on the server to reset or power off the server. (HP ProLiant servers (except the 1xx series) support this kind of fencing using iLO remote management - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 22
step verifies that the SAN devices are configured appropriately and can be viewed from the servers that will be in the cluster. Perform this step on each server. 1. Load the HBA drivers provided with HP X5500 Storage Gateway for Linux using the following command: # /etc/init.d/pmxs load. NOTE: Do - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 23
for FalconStor This step is needed only if a FalconStor device is included in your SAN configuration. The HP X5500 Storage Gateway for Linux psd_round2_delay parameter must be set manually on each server. This parameter is located in the scl.conf file, which by default is located at /etc/ opt - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 24
cluster using the Management Console To start the Management Console, execute the following command: $ mxconsole On the HP X5500 Storage Gateway for Linux Connect window, type the host name or IP address of the server in the "Connect to" field. Then click on the down-arrow on the Connect button. You - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 25
security for network communications among the cluster servers. To set this key, click Set problems occur on a server (for example, hardware problems or the loss of cluster network communications), and the server ceases to effectively coordinate and communicate with other servers in the cluster, HP - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 26
the appropriate value here. The SNMP community string must be set to the same value on HP X5500 Storage Gateway for Linux and on the SAN switches configured above. When you have completed Management Controller associated with the server that you used to connect to the Management Console. 26 Set up - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 27
servers that will be in the cluster. During the export, HP servers. If a particular entry on the SAN & Fencing tab did not apply to all servers, HP HP X5500 Storage Gateway for Linux will fail to fence a server if another IPMI session is already active on that server with this cluster server. You will - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 28
is not shared, you will be asked for the appropriate logins when the other servers are added to the cluster. Fencing action. When a server needs to be restricted from the SAN, HP X5500 Storage Gateway for Linux can either power-cycle the server or shut it down. Select the method that you want to use - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 29
Community String. The default SNMP community string for HP X5500 Storage Gateway for Linux is private. If SNMP community string must be set to the same value on both HP X5500 Storage Gateway for Linux and the SAN switches configured above. HP StorageWorks X5500 Network Storage Gateway for Linux setup - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 30
and to store the device naming database, which includes the global device names that HP X5500 Storage Gateway for Linux assigns to the SAN disks placed under its control Create LUNs or disk partitions for membership partitions, page 20. HP X5500 Storage Gateway for Linux can use either one or three - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 31
. Snapshot Configuration. HP X5500 Storage Gateway for Linux provides support for taking hardware be located on storage arrays supported for snapshots.) If you and then supply the configuration information. If you are using an HP EVA array, HP StorageWorks X5500 Network Storage Gateway for Linux setup - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 32
For XP arrays, you will be asked for the local and remote instance numbers of your XP RAID Manager configuration. For Engenio arrays, you will be asked for the hostnames or IP addresses and password for your storage array controllers. 32 Set up HP X5500 Storage Gateway for Linux solutions - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 33
start the HP X5500 Storage Gateway for Linux software on that server. If HP X5500 Storage Gateway for Linux on specific servers and to test the fencing configuration. Select the servers to be configured. To specify the first server, click Add Server and type the hostname or IP address of the server - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 34
in the Address column. Click Start Service to start HP X5500 Storage Gateway for Linux on those servers. As each server is started, a status message will with the server, export the cluster configuration to that server and then supply the correct information. 9. Configure HP X5500 Storage - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 35
: 1. Using the Management Console: a. Select the Servers tab. b. Repeat the following steps for each public guide for information about configuring and using HP X5500 Storage Gateway for Linux features such as clustered PSFS filesystems, the administrative filesystem, NFS and Samba/CIFS file services - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 36
are used for internal, server-to-server communication. Should you have HP X5500 Storage Gateway for service, they can easily be reconfigured as described under "Change configurable port numbers" in the HP StorageWorks X5500 Network Storage Gateway for Linux File Serving Software administration guide - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 37
/sysconfig/nfs file to ensure that they are consistent across reboots. HP recommends that you use the following ports. Port 111 111 861 861 Service NetBIOS SMB Service NetBIOS Datagram Service NetBIOS Datagram Service NetBIOS Sessions Service NetBIOS Sessions Service Microsoft Directory Service HP - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 38
On HP X5500 Storage Gateway for Linux servers and HP 4400 Scalable NAS File Services systems, . If you do adjust system parameters to support external applications such as Oracle, you should best performance for your application. HP does not recommend manually editing the SizingActions script, as - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 39
Disaster recovery Disaster recovery HP X5500 Storage Gateway for Linux servers in the cluster are redundant components that should keep a server running, in most scenarios. If you must replace a server or re-image the operating system HP StorageWorks X5500 Network Storage Gateway for Linux setup - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 40
40 Disaster recovery procedures - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 41
, new driver versions, firmware updates, and other product resources. HP websites For additional information, see the following HP websites: • http://www.hp.com • http://www.hp.com/go/scalablenas • http://www.hp.com/go/storage • http://www.hp.com/support/manuals Documentation feedback HP welcomes - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 42
42 Support and other resources - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 43
module • Extract HP X5500 Storage computed symbols for the specific kernel configuration they rpm • The kernel architecture-specific source RPM: kernel-source-2.6.16 now ready to support compilation of third HP X5500 Storage Gateway for Linux kernel patches Compiling third-party software using the HP - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 44
are being integrated into a custom kernel configuration not defined by HP. You may need to override the mxmodver utility and manually select the appropriate (pre-configured, pre-compiled) version of the pmxs kernel modules before starting HP X5500 Storage Gateway for Linux on the new kernel. Rebuild - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 45
HP X5500 Storage Gateway for Linux systems. This appendix serves as reference information for HP to provide multipath support for HP X5500 Storage Gateway for Mapper Multipath RPMs on each server. The RPMs are provided Device Mapper Multipath Download the HP Device Mapper Multipath Enablement Kit and - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 46
modules: # /etc/init/pmxs unload c. Start multipath services: # /etc/init.d/multipathd start d. Restart HP X5500 Storage Gateway for Linux: # /etc/init/pmxs start Update the fc_pcitable file Update the entry for your Fibre Channel Adapter device driver as described below. Format of the fc_pcitable - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 47
HBA drivers: /etc/init.d/pmxs unload If the multipath devices are not removed before running the pmxs unload command, the HBA drivers will not be unloaded because the multipath devices are associated with storage on those adapters. HP StorageWorks X5500 Network Storage Gateway for Linux setup guide - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 48
48 Configure Linux Device Mapper MPIO - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 49
line HP X5500 the commands must be entered in a specific order. The following examples show the necessary commands are run from nodeA by a user having the appropriate HP X5500 Storage Gateway for Linux permissions on that node. IMPORTANT: HP StorageWorks X5500 Network Storage Gateway for Linux setup - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 50
needed only if you will be using the snapshot feature.) mx --matrix nodeA server add nodeA mx --matrix nodeA server start nodeA mx --matrix nodeA config description The cluster is now configured and HP X5500 Storage Gateway for Linux is running on nodeA. Repeat the following commands - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 51
] Now start HP X5500 Storage Gateway for Linux on the servers: mx --matrix nodeA server start The config to all the other nodes and start them up. ${MX} server start ${MATRIX} || exit 1 for NODE in ${NODES}; do ${MX} server add ${NODE} || exit 1 ${MX} config export ${NODE} || - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 52
the following information. mx config loaddrivers Load the HP X5500 Storage Gateway for Linux pmxs drivers. mx config license The location of the HP X5500 Storage Gateway for Linux license file. The file must be present on the server running the command. mx config secret - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 53
server add Add the specified node to the cluster. mx server start Start HP Remote Management Controller associated with this server. You will need to use this server's IP address to determine the IP addresses of the associated Remote Management Controllers. For example, if your servers - HP ProLiant DL380G5-WSS | HP StorageWorks X5500 Network Storage Gateway for Linu - Page 54
, HP X5500 Storage Gateway for Linux can either power-cycle the server or shut it down. Select the method that you want to use (either reset or shutdown). mx config snapshot add --method [--options ] Configure a snapshot method. The options are: --method The supported
HP StorageWorks X5500 Network Storage
Gateway for Linux setup guide
This guide provides information about setting up the HP StorageWorks X5500 Network Storage Gateway for
Linux (formerly known as HP Scalable NAS Clustered Gateway). This guide is intended for administrators who
will be performing the setup.
Part number: AP811
–
96003
First edition: October 2009