- HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 1
HP ProLiant ML310e Gen8 Server User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 2
HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. Microsoft® and Windows - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 3
header...13 Drive numbering ...14 Drive LED definitions ...15 FBWC module LED definitions...16 Fan locations ...17 T-10/T-15 Torx screwdriver ...17 Operations...18 Power up the server ...18 Power down the server...18 Unlock the tower bezel ...19 Remove the tower bezel ...19 Install the tower bezel - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 4
Provisioning...69 HP Insight Remote Support software 71 Scripting Toolkit ...71 HP Service Pack for ProLiant ...72 HP Smart Update Manager...72 HP ROM-Based Setup Utility ...72 Using RBSU ...73 Auto-configuration process...73 Boot options ...74 Re-entering the server serial number and product ID - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 5
the system current ...77 Drivers ...77 Software and firmware...77 Version control ...77 HP Operating Systems and Virtualization Software Support for ProLiant Servers 78 Change control and proactive notification 78 Troubleshooting ...79 Troubleshooting resources ...79 System battery replacement - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 6
Before you contact HP...92 HP contact information ...92 Customer Self Repair ...92 Acronyms and abbreviations...100 Documentation feedback ...104 Index...105 Contents 6 - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 7
Component identification Front panel components Item 1 2 3 4 5 Description Optical drive (optional) Media drive bay USB connectors Power On/Standby button and system power LED Drive bays (inside) Component identification 7 - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 8
Front panel LEDs and buttons Item 1 2 3 4 Description UID LED button Health LED NIC status LED Power On/Standby button and system power LED Status Blue = Identification is activated Flashing blue = System is being managed remotely Off = Identification is deactivated Green = Normal (system on) - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 9
Rear panel components Item 1 2 3 4 5 6 7 8 9 10 11 12 Description Non-hot-plug power supply Slot 4 PCIe x16 (8, 4, 1)* Slot 3 PCIe x8 (8, 4, 1)* Slot 2 PCIe x8 (4, 1)* Slot 1 PCIe x4 (1)* Expansion slot cover retainer Serial connector Video connector Dedicated iLO management port (optional) NIC 1/ - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 10
Blue = Identification is activated Flashing blue = System is being managed remotely Off = Identification is deactivated Power supply LED (for hot-plug HP Green = Normal CS power supplies only)* Off = One or more of the following conditions exists: • Power is unavailable • Power supply failed - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 11
System board components Item 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 2 PCIe x8 (4, 1)* Slot 3 PCIe x8 (8, 4, 1)* Slot 4 PCIe x16 (8, 4, 1)* Fan connector 1 TPM connector 4-pin power supply connector Dedicated iLO module connector DIMM slots Component identification 11 - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 12
slots are numbered sequentially (1 through 4) for the processor. The supported AMP modes use installed. The slots can either run in PCIe2 (5 GT/s) or PCIe3 (8 GT/s) rate. • Intel Xeon Processor E3-xxxx Series, Intel Core i3 Processor Series, Intel Pentium G2120, and Intel Celeron G540 Slot number - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 13
and NVRAM. CAUTION: Clearing CMOS and/or NVRAM deletes configuration information. Be sure to properly configure the server or data loss could occur. NMI header The NMI header enables administrators to perform a memory dump before performing a hard reset. Crash dump analysis is an essential part of - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 14
Drive numbering • Four-bay LFF drive model • Eight-bay SFF drive model Component identification 14 - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 15
, or logical drive extension, or is erasing. The drive is a member of one or more logical drives and predicts the drive will fail. The drive is not configured and predicts the drive will fail. Solid amber The drive has failed. Off The drive is not configured by a RAID controller. Component - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 16
is charged, and the cache contains data that has not yet been written to the drives. Flashing 1 Hz Off A backup Data may be corrupt. On Off An overtemperature condition exists. Flashing 2 Hz Off The capacitor pack is not attached. Flashing 2 Hz On The capacitor has been charging for 10 - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 17
cooling) Front system fan (fan 2, for expansion board cooling) T-10/T-15 Torx screwdriver The server includes a T-10/T-15 Torx screwdriver located on the side of the media drive cage. Use the screwdriver to loosen screws during hardware configuration procedures. Component identification 17 - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 18
down the server Before powering down the server for any upgrade or maintenance procedures, perform a backup of critical server data and iLO. This method initiates a controlled remote shutdown of applications and the OS before the server enters standby mode. Before proceeding, verify the server - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 19
drive cage and media bays. It must be unlocked to remove the access panel. The bezel must remain closed during normal server operations. Remove the tower bezel 1. Unlock and open the tower bezel ("Unlock the tower bezel" on page 19). 2. Pull the bezel away from the front chassis. Install - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 20
injury from hot surfaces, allow the drives and the internal system components to cool before touching them. CAUTION: For proper cooling, do not operate the server without the access panel, baffles, expansion slot covers, or blanks installed. If the server supports hot-plug components, minimize the - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 21
. 2. Lock the tower bezel. Remove the air baffle CAUTION: For proper cooling, do not operate the server without the access panel, baffles, expansion slot covers, or blanks installed. If the server supports hot-plug components, minimize the amount of time the access panel is open. Operations 21 - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 22
all power: a. Disconnect each power cord from the power source. b. Disconnect each power cord from the server. 3. Unlock the tower bezel (on page 19). 4. Remove the access panel (on page 20). 5. Remove the air baffle. Install the air baffle 1. Insert the tabs on the baffle to the slots on the rear - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 23
4. Lock the tower bezel. 5. Power up the server (on page 18). Operations 23 - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 24
specifically for HP ProLiant systems. HP Care Packs let you integrate both hardware and software support into a single package. A number of service level options are available to meet your needs. HP Care Pack Services offer upgraded service levels to expand your standard product warranty with - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 25
. This equipment is designed to operate in installations covered by NFPA 70, 1999 Edition (National Electric Code) and NFPA-75, 1992 (code for Protection of Electronic Computer/Data Processing Equipment). For electrical power ratings on options, see the product rating label or the user documentation - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 26
and guidelines for manual material handling. • Get help to lift and stabilize the product during installation or removal, especially when the product is not fastened to the rails. HP recommends that a minimum of two people are required for all rack server installations. A third person may - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 27
of the server shipping carton include: • Server • Power cord • Printed setup documentation, Documentation CD, and software products You need the following items for some procedures: • T-10/T-15 Torx screwdriver (on page 17) • Flathead screwdriver (for dedicated iLO module installation) • Hardware - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 28
, updating, and provisioning capabilities. Intelligent Provisioning can configure the server and install an operating system, eliminating the need for SmartStart CDs and Smart Update Firmware DVDs. To install an operating system on the server with Intelligent Provisioning (local or remote): Setup 28 - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 29
to a RAID configuration based on the size and number of hard drives installed. For more information on modifying the controller default settings, see the documentation on the Documentation CD. For more information on automatic configuration, see the HP ROM-Based Setup Utility User Guide on the - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 30
card option supports both SATA and SAS drives. Drive installation guidelines When adding hard drives to the server, observe the following general guidelines: • The system automatically sets all drive numbers. • Populate drive bays, based on the drive numbering sequence. Start from the drive bay with - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 31
4. Remove the drive carrier. 5. Remove the two metal brackets from the drive carrier. 6. Install the drive in the carrier. Hardware options installation 31 - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 32
bezel. 9. Connect each power cord to the server. 10. Connect each power cord to the power source. 11. Power up the server (on page 18). Installing a hot-plug drive CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 33
3. Prepare the drive. 4. Install the drive. 5. Determine the status of the drive from the drive LED definitions (on page 15). 6. Close and lock the tower bezel. Drive cage options Four-bay LFF hot-plug drive backplane option To install the component: 1. Power down the server (on page 18). 2. Remove - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 34
: a. Disconnect the Mini-SAS cable from the system board or from the storage controller option. b. Disconnect the drive power cable from the 10-pin power supply connector. 8. Remove the drive cage assembly. 9. Loosen the bracket thumbscrew, and then remove the non-hot-plug bracket assembly from the - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 35
hot-plug drive backplane to the drive cage, and then tighten the thumbscrew. 11. Install the drive cage assembly. 12. Connect the drive backplane cables: a. Connect the power cable to the backplane. b. Do one of the following: - Connect the Mini-SAS cable to the system board (SATA drive support only - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 36
). For cable routing information, see "Hot-plug, SATA and SAS drive support (on page 63)." 13. Install the drives ("Drive options" on page 30). CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank. 14 - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 37
from the power source. b. Disconnect each power cord from the server. 3. Remove the tower bezel (on page 19). 4. Remove the access panel (on page 20). 5. Remove the air baffle (on page 21). 6. Remove all installed drives. 7. Disconnect the drive cage cables: a. Disconnect the Mini-SAS cable from the - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 38
controller option. For cable routing information, see "Eight-bay SFF drive cabling (on page 63)." 11. Install the drives ("Drive options" on page 30). CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 39
Smart Array Controllers Reference Guide on the HP website (http://www.hp.com/support/CASAC_RG_en). Upgrade options exist for the integrated array controller. For a list of supported options, see the QuickSpecs on the HP website (http://www.hp.com/support). The server supports FBWC. FBWC consists of - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 40
/CASAC_RG_en). Upgrade options exist for the integrated array controller. For a list of supported options, see the QuickSpecs on the HP website (http://www.hp.com/support). Installing the FBWC module and capacitor pack CAUTION: In systems that use external data storage, be sure that the server is - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 41
6. Install the cache module on the storage controller. 7. Connect the capacitor pack cable to the cache module. 8. Install the storage controller ("Installing a storage controller" on page 39). Hardware options installation 41 - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 42
Install the capacitor pack. 10. Install the air baffle (on page 22). 11. Install the access panel (on page 21). 12. Lock the tower bezel. 13. Connect each power cord to the server. 14. Connect each power cord to the power source. 15. Power up the server (on page 18). Optical drive option To install - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 43
5. Remove the media bay blank. 6. Remove the EMI shield. Hardware options installation 43 - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 44
information, see "Media drive cabling (on page 64)." 9. Install the access panel (on page 21). 10. Install the tower bezel (on page 19). 11. Connect each power cord to the server. 12. Connect each power cord to the power source. 13. Power up the server (on page 18). Memory options Hardware options - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 45
the processor model and the number of DIMMs installed, the memory clock speed might be reduced to 1333 or 1066 MHz. The server supports a maximum system memory of 32 GB, using 2-GB, 4-GB, and 8-GB UDIMMs. HP SmartMemory HP SmartMemory, introduced for Gen8 servers, authenticates and unlocks certain - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 46
R = RDIMM (registered) E = UDIMM (unbuffered with ECC) L = LRDIMM (load reduced) For the latest supported memory information, see the QuickSpecs on the HP website (http://h18000.www1.hp.com/products/quickspecs/ProductBulletin.html). At the website, choose the geographic region, and then locate the - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 47
indicates the first slot of a channel (2-A, 4-B). • Memory speed support depends on the type of processor installed. See the technical specification of the installed processor for more information. • The server supports up to 1600 MT/s ECC UDIMMs. • The server supports up to 32 GB (4x8 GB) UDIMMs - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 48
each power cord to the power source. 13. Power up the server (on page 18). After installing the DIMMs, to configure the memory protection mode, use RBSU ("HP ROM-Based Setup Utility" on page 72). Expansion board options The server has both full-height and low-profile expansion slots for controller - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 49
6. Remove the expansion slot cover retainer. 7. Identify the expansion slot compatible with the new option, and then remove the cover opposite that slot. Hardware options installation 49 - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 50
8. If installing a full-length expansion board, remove the board retainer. 9. Install the expansion board. Hardware options installation 50 - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 51
10. If installing a full-length expansion board, install back the board retainer. 11. Install the expansion slot cover retainer option. 13. Install the air baffle (on page 22). 14. Install the access panel (on page 21). 15. Lock the tower bezel. 16. Connect each power cord to the server. 17. Connect - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 52
Dedicated iLO management port option To install the component: 1. Power down the server (on page 18). 2. Unlock the tower bezel (on page 19). 3. Remove the access panel (on page 20). screwdriver, toggle the knockout to loosen it, and then pull it out of the chassis. Hardware options installation 52 - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 53
the dedicated iLO management module. 9. Install the rear system fan. 10. Install any removed expansion board. 11. Install the air baffle (on page 22). 12. Install the access panel (on page 21). 13. Lock the tower bezel. 14. Connect each power cord to the server. 15. Connect each power cord to - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 54
requires accessing RBSU ("HP ROM-Based Setup Utility" on page 72). For more information about RBSU, see the HP website (http://www.hp.com/go/ilomgmtengine/docs). TPM installation requires the use of drive encryption technology, such as the Microsoft Windows BitLocker Drive Encryption feature. For - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 55
the TPM security rivet. Upon locating a broken or disfigured rivet on an installed TPM, administrators should consider the system compromised and take appropriate measures to ensure the integrity of the system data. 7. Install the TPM board. Press down on the connector to seat the board ("System - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 56
. Install the access panel (on page 21). 13. Lock the tower bezel. 14. Connect each power cord to the server. 15. Connect each power cord to the power source. 16. Power up the server (on page 18). Retaining the recovery key/password The recovery key/password is generated during BitLocker™ setup, and - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 57
OS. For OS-specific instructions, see the OS documentation. CAUTION: When a TPM is installed and enabled on the server, data access is locked if you fail to follow the proper procedures for updating the system or option firmware, replacing the system board, replacing a hard drive, or modifying OS - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 58
6. Remove the power supply. 7. Disconnect all cables from installed media drives. 8. Remove all installed devices and any EMI shields from the media drive bays. 9. Install the RPS cage. Hardware options installation 58 - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 59
in the server must have the same output power capacity. Verify that all power supplies have the same part number and label color. The system becomes unstable and might shut down when it detects mismatched power supplies. 14. For improved power efficiency and redundancy, install two HP CS power - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 60
a. Remove the EMI shield. b. Install the HP CS power supplies. 15. Install any device originally installed in the upper media drive bay. 16. Install the EMI shield in the lower media drive bay. 17. Install the access panel (on page 21). 18. If the lower media bay blank is not attached to the tower - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 61
(http://www.hp.com/products/servers/platforms). CAUTION: When routing cables, always be sure that the cables are not in a position where they can be pinched or crimped. Storage cabling Four-bay LFF drive cabling Non-hot-plug, SATA drive support only Item Description 1 Power cable 2 Data cable - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 62
Non-hot-plug, SATA and SAS drive support Item Description 1 Power cable 2 Data cable Hot-plug, SATA drive support Item Description 1 Power cable 2 Mini-SAS cable Cabling 62 - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 63
Hot-plug, SATA and SAS drive support Item Description 1 Power cable 2 Mini-SAS cable Eight-bay SFF drive cabling This drive configuration supports hot-plug SATA and SAS drives. Item 1 2 3 Description Power cable Mini-SAS cable Mini-SAS cable Cabling 63 - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 64
Item 1 2 3 4 Description Upper media drive power cable Lower media drive SATA cable Upper media drive SATA cable Lower media drive power cable • Media drive in a redundant power configuration Item 1 2 Description Upper media drive SATA cable Upper media drive power cable Cabling 64 - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 65
Power supply cabling Nonredundant power supply cabling Item 1 2 Description 24-pin power supply cable 4-pin power supply cable Redundant power supply cabling Item Description 1 24-pin power supply cable 2 26-pin RPS cable Cabling 65 - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 66
Item 3 Description 4-pin power supply cable (with the 8-pin to 4-pin adapter cable connected) Capacitor pack cabling Cabling 66 - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 67
Diagnostics (on page 70) HP Insight Remote Support software (on page 71) Erase Utility (on page 70) Scripting Toolkit (on page 71) HP Service Pack for ProLiant (on page 72) HP Smart Update Manager (on page 72) HP ROM-Based Setup Utility (on page 72) Array Configuration Utility (on page 74) Option - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 68
state of the host server. • Access Active Health System troubleshooting features through the iLO interface. • Subscribe to HP Insight Remote Support software without installing any drivers or agents. For more information about iLO features (which may require an iLO Advanced Pack or iLO Advanced for - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 69
o For Windows: IML Viewer o For Linux: IML Viewer Application • From within the iLO user interface • From within HP Insight Diagnostics (on page 70) Intelligent Provisioning Several packaging changes have taken place with HP ProLiant Gen8 servers: SmartStart CDs and the Smart Update Firmware DVD - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 70
utility sets the system to its original factory state, deletes the current hardware configuration information, including array setup and disk partitioning, and erases all connected hard drives completely. Refer to the instructions for using this utility. The Erase utility enables you to erase system - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 71
Support software HP strongly recommends that you install HP Insight Remote Support software to complete the installation or upgrade of your product and to enable enhanced delivery of your HP Warranty, HP Care Pack Service, or HP contractual support agreement. HP Insight Remote Support supplements - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 72
Enables direct update of BMC firmware (HP iLO) For more information about HP SUM and to access the HP Smart Update Manager User Guide, see the HP website (http://www.hp.com/go/hpsum/documentation). HP ROM-Based Setup Utility RBSU is a configuration utility embedded in ProLiant servers that performs - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 73
installed 1 2 3, 4, 5, or 6 More than 6 Drives used 1 2 3, 4, 5, or 6 0 RAID level RAID 0 RAID 1 RAID 5 None To change any ORCA default settings and override the auto-configuration process, press the F8 key when prompted. For more information on RBSU, see the HP ROM-Based Setup Utility User Guide - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 74
. The server automatically reboots. Utilities and features Array Configuration Utility ACU is a utility with the following features: • Runs as a local application or remote service accessed through the HP System Management Homepage • Supports online array capacity expansion, logical drive extension - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 75
, see the HP Smart Array Controllers for HP ProLiant Servers User Guide on the HP website (http://www.hp.com/support/SAC_UG_ProLiantServers_en). To configure arrays, see the Configuring Arrays on HP Smart Array Controllers Reference Guide on the HP website (http://www.hp.com/support/CASAC_RG_en - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 76
Smart Array Controllers for HP ProLiant Servers User Guide on the HP website (http://www.hp.com/support/SAC_UG_ProLiantServers_en). To configure arrays, see the Configuring Arrays on HP Smart Array Controllers Reference Guide on the HP website (http://www.hp.com/support/CASAC_RG_en). ROMPaq utility - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 77
a backup before installing or updating device drivers. The server includes new hardware that may not have driver support on all OS installation media. If you are installing an Intelligent Provisioning-supported OS, use Intelligent Provisioning (on page 69) and its Configure and Install feature to - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 78
tools, see the HP Systems Insight Manager User Guide, the HP Version Control Agent User Guide, and the HP Version Control Repository User Guide on the HP website (http://www.hp.com/go/hpsim). HP Operating Systems and Virtualization Software Support for ProLiant Servers For information about specific - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 79
) • Simplified Chinese (http://www.hp.com/support/ProLiant_TSG_v1_sc) The HP ProLiant Gen8 Troubleshooting Guide, Volume II: Error Messages provides a list of error messages and information to assist with interpreting and resolving error messages on ProLiant servers and server blades. To view the - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 80
server no longer automatically displays the correct date and time, you might have to replace the battery that provides power to the real-time clock. Under normal use, battery life is 5 to 10 for this product. To remove the component: 1. Power down the server (on its default configuration. After - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 81
For more information about battery replacement or proper disposal, contact an authorized reseller or an authorized service provider. System battery replacement 81 - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 82
limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to Regulatory - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 83
not occur in a particular installation. If this equipment does Mail Stop 530113 Houston, Texas 77269-2000 • 1-800-HP-INVENT (1-800-474-6836). (For continuous quality improvement 3333 To identify this product, refer to the part, series, or model number found on the product. Modifications The FCC - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 84
listed in the EU Declaration of Conformity issued by HP for this product or product family and available (in English only) either within the product documentation or at the following HP website (http://www.hp.eu/certificates) (type the product number in the search field). The compliance is indicated - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 85
conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can city office, your household waste disposal service or the shop where you purchased the product. Japanese notice BSMI notice Korean notice - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 86
or DVD drive) and/or fiber optic transceiver. Each of these devices contains a laser that is classified as a Class 1 Laser Product in accordance with US FDA regulations and the IEC 60825-1. The product does not emit hazardous laser radiation. Each laser product complies with 21 CFR 1040.10 and 1040 - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 87
of procedures other than those specified herein or in the laser product's installation guide may result in hazardous radiation exposure. To reduce the risk of laser device other than those specified herein. • Allow only HP Authorized Service technicians to repair the unit. The Center for Devices and - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 88
Acoustics statement for Germany (Geräuschemission) Schalldruckpegel LpA < 70 dB(A) Zuschauerpositionen (bystander positions), Normaler Betrieb (normal operation) Nach ISO 7779:1999 (Typprüfung) Regulatory compliance notices 88 - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 89
of 1 megohm ±10 percent resistance in the service kit with a folding static-dissipating work mat. If you do not have any of the suggested equipment for proper grounding, have an authorized reseller install the part. For more information on static electricity or assistance with product installation - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 90
.90 kg (26.21 lb) 19.00 kg (41.85 lb) Power supply specifications Depending on installed options, the server is configured with one of the following power supplies: • HP 350 W 4U Factory Integrated Power Supply • HP 460 W CS Gold Hot-plug Power Supply (92% efficiency) CAUTION: Check the system and - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 91
AC input 400 W at 100 V AC input 400 W at 200 V AC input 350 W HP 460 W CS Gold Hot-plug Power Supply (92% efficiency) Specification Input requirements Rated input voltage Rated server, refer to the HP Enterprise Configurator website (http://h30099.www3.hp.com/configurator/). Specifications 91 - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 92
HP iLO 4 User Guide or HP Intelligent Provisioning User Guide on the HP website (http://www.hp.com/go/ilo/docs). • Onboard Administrator SHOW ALL report (for HP BladeSystem products (service upgrade), see the Support & Drivers website (http://www8.hp.com/us/en/support-drivers.html). If the problem - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 93
HP replace them for you, there may or may not be additional charges, depending on the type of warranty service designated for your product. NOTE: Some HP required, you can call the HP Technical Support Center and a technician will help you over the telephone. HP specifies in the materials shipped - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 94
optional ist. Diese Teile sind auch für Customer Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen Garantiebedingungen zusätzliche Kosten anfallen. Support and other resources 94 - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 95
Lieferung am selben Tag oder innerhalb von vier Stunden gegen einen Aufpreis verfügbar. Wenn Sie Hilfe benötigen, können Sie das HP technische Support Center anrufen und sich von einem Mitarbeiter per Telefon helfen lassen. Den Materialien, die mit einem CSR-Ersatzteil geliefert werden, können Sie - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 96
cliente de HP, póngase HP siguiente (http://www.hp.com/go/selfrepair). Customer Self Repair Veel onderdelen in HP HP (of een HP Service product. OPMERKING: Sommige HP HP Service Partner om via de telefoon technische ondersteuning te ontvangen. HP a HP (ou fornecedores/parceiros de serviço da HP) concluir - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 97
transportadora/serviço postal a ser utilizado. Para obter mais informações sobre o programa de reparo feito pelo cliente da HP, entre em contato com o fornecedor de serviços local. Para o programa norte-americano, visite o site da HP (http://www.hp.com/go/selfrepair). Support and other resources 97 - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 98
Support and other resources 98 - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 99
Support and other resources 99 - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 100
Acronyms and abbreviations ABEND abnormal end ACU Array Configuration Utility AMP Advanced Memory Protection ASR Automatic Server Recovery BMC baseboard management controller BSMI Bureau of Standards, Metrology and Inspection CE Conformité Européenne (European Conformity) CSA Canadian Standards - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 101
supply) HP SIM HP Systems Insight Manager HP SUM HP Smart Update Manager IEC International Electrotechnical Commission iLO Integrated Lights-Out IML Integrated Management Log ISO International Organization for Standardization LFF large form factor LRDIMM load reduced dual in-line memory module NMI - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 102
ROM-Based Setup Utility RDIMM registered dual in-line memory module RDP Rapid Deployment Pack RF radio frequency RFI radio frequency interference RPS redundant power supply SAS serial attached SCSI SATA serial ATA SD Secure Digital SFF small form factor SPP HP Service Pack for ProLiant Acronyms and - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 103
TMRA recommended ambient operating temperature TPM Trusted Platform Module UDIMM unregistered dual in-line memory module UID unit identification USB universal serial bus VCA Version Control Agent VCRM Version Control Repository Manager Acronyms and abbreviations 103 - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 104
that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback (mailto:[email protected]). Include the document title and part number, version number, or the URL when submitting your feedback. Documentation feedback 104 - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 105
reseller 92 auto-configuration process 73 Automatic Server Recovery (ASR) 76 B battery 80, 87 battery, installing 80 bezel 19 bezel, removing 19 BIOS upgrade 67, 76 board components 11 boot options 29, 74 BSMI notice 85 buttons 7 buttons, front panel 8 buttons, rear panel 10 C cables 61, 83 - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 106
H hard drives, installing 30, 32 hardware options installation 30 health driver 76 help resources 92 Hot-plug SAS/SATA hard drive cabling 61 HP Insight Diagnostics 70 HP Insight Remote Support software 71 HP Smart Update Manager overview 67, 72 HP technical support 92 I identification number 82 iLO - HP ProLiant ML310e | HP ProLiant ML310e Gen8 Server User Guide - Page 107
number 82 server features and options 30 Server mode 67 server setup 27 server specifications 90, 91 server, front panel components 7 server, front panel LEDs 8 server, real panel LEDs 10 server, rear panel components 9 Service Packs 72 SFF drive cage 37 shipping carton contents 27 Smart Update
HP ProLiant ML310e Gen8 Server
User Guide
Abstract
This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the
servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels.
Part Number: 682266-001
September 2012
Edition: 1