HP SN6000 HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen
HP SN6000 Manual
View all HP SN6000 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP SN6000 manual content summary:
- HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 1
HP StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide This guide describes the HP StorageWorks SN6000 Fibre Channel Switch features and capabilities, planning considerations, installation, diagnostics, and troubleshooting. This guide is intended for users who are responsible - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 2
trademark of Sun Microsystems, Inc. Microsoft, Windows, and Internet Explorer are registered trademarks of Microsoft Corporation. Netscape Navigator and Mozilla are registered trademarks of Netscape Communications Corporation. HP StorageWorks SN6000 Fibre Channel Switch Installation and Reference - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 3
29 Connection security 30 Device security 30 Fabric management 31 3 Installation 33 Site requirements 33 Management station and workstation requirements 33 Switch power requirements 34 Environmental conditions 34 HP StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide 3 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 4
44 Custom firmware installation 45 Adding a switch to an existing fabric 46 Installing feature license keys 46 Configuring Call Home to HP Services (optional 46 Role of the Remote Support Software Manager 47 Role of OSEM and versions required 47 Installation instructions and documentation - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 5
84 Factory event logging configuration 84 Factory NTP server configuration 84 Factory timer configuration 85 Factory RADIUS configuration 85 Factory security configuration 85 Factory Call Home configuration 86 HP StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide 5 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 6
21 6 Port-to-port latency 22 7 Management station requirements for Simple SAN Connection Manager and Enterprise Fabric Management Suite 33 8 Workstation requirements for QuickTools 34 9 8/20q and SN6000 Fibre Channel Switch rack mount kit hardware 36 10 Document conventions 65 11 General - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 7
27 NTP server configuration defaults 84 28 Timer configuration defaults 84 29 RADIUS configuration defaults 85 30 Security configuration defaults 85 31 Call Home service configuration defaults 86 HP StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide 7 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 8
8 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 9
, IP network configuration, administrative password control, Simple Network Management Protocol (SNMP) setup, firmware upgrades, and implementation of HP best zoning practices (single initiator zoning). • For more information about the CLI, see the HP StorageWorks SN6000 Fibre Channel Switch Command - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 10
blink patterns" (page 52). System fault LED (amber) The System Fault LED illuminates to indicate that a fault exists in the switch firmware or hardware. Fault conditions include POST errors, over-temperature conditions, and power supply malfunctions. The Heartbeat LED shows a blink code for POST - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 11
. The Heartbeat LED illuminates continuously while the switch is in maintenance mode. To exit maintenance mode and return to normal operation, press and release the Maintenance button momentarily to reset the switch. HP StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide 11 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 12
Fibre Channel ports The HP StorageWorks SN6000 Fibre Channel Switch has 20 Fibre Channel Small Form-Factor Pluggable (SFP) ports and four Fibre Channel provide port login and activity status. The SN6000 Fibre Channel Switch-Single Power Supply is available as a 12- or 24-port switch. This means that - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 13
The Activity LED indicates that data is passing through the port. Each frame that the port transmits or receives illuminates this LED for 50 milliseconds. This makes it possible to observe the transmission of a single frame. Transceivers The HP StorageWorks SN6000 Fibre Channel Switch supports SFP - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 14
20q Fibre Channel switches. The SN6000 Fibre Channel Switch self-discovers all inter-switch connections. For more information, see "Multiple switch fabrics" (page 22). TR_Port Transparent routing port-expands the fabric by connecting an SN6000 Fibre Channel Switch to an HP StorageWorks B-series or - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 15
serial port for maintenance purposes (Figure 6). You can manage the switch through the serial port using the CLI. 2 1 1 Serial port Figure 6 Serial port and pin identification 2 RS-232 connector pin identification HP StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide 15 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 16
monitor or report fan operational status. Air flow is front-to-back. To energize the switch, plug the power cord into the switch AC receptacle and into a 100-240 VAC power source. The SN6000 Fibre Channel Switch-Dual Power Supply has two hot-pluggable power supplies that convert standard 100-240 VAC - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 17
capabilities beyond those of Simple SAN Connection Manager. You run QuickTools by opening the switch IP address with an internet browser on your workstation. See the HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide. QuickTools provides the following management - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 18
can be downloaded with a 30-day trial license from the HP website: www.hp.com/go/EFMS. For information about configuring the switch using Enterprise Fabric Management Suite, see the HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Enterprise Fabric Management Suite User Guide. Simple Network - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 19
. A zone can be a component of more than one zone set. Several zone sets can be defined for a fabric, but only one zone set can be active at one time. The active zone set determines the current fabric zoning. HP StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide 19 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 20
switch. Table 3 describes the zoning database limits, excluding the active Performance The SN6000 Fibre Channel Switch supports class 2 and class 3 Fibre Channel service at loses a credit in the process. For example, you can configure an SFP recipient port to borrow 15 credits from one donor - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 21
supported distances, see the SAN Design Reference Guide available at the HP website: http://www.hp With an SN6000 Stackable 20Gb ISL switches. The switch guarantees in-order delivery with any number of links between chassis. HP StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 22
default 10 Gb/s. • The HP StorageWorks SN6000 Stackable 4-port FC Switch Upgrade LTU enables additional SFP ports in increments of four on the HP StorageWorks SN6000 Stackable 8Gb 12-port Single Power FC Switch Fibre Channel ports are self-configuring, you can connect SN6000 Fibre Channel Switches - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 23
set to 254. For information about changing the default domain ID, domain ID lock, and principal priority parameters, see the set config switch command in the HP StorageWorks SN6000 Fibre Channel Switch Command Line Interface Guide. If you connect a new switch to an existing fabric with its domain ID - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 24
at 8 Gb/s. Figure 8 shows a two-switch stack of model SN6000 switches using two 3-inch XPAK switch stacking cables. 40 SFP ports are available for devices. Figure 8 Two-switch stack Figure 9 shows a three-switch stack of HP StorageWorks SN6000 Fibre Channel Switch switches using two 3-inch and one - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 25
available for devices. Figure 11 Five-switch stack Figure 12 shows a six-switch stack of model SN6000 switches using eight XPAK switch stacking cables. 120 SFP ports are available for devices. Figure 12 Six-switch stack HP StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide 25 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 26
a SN6000 Fibre Channel Switch (local) fabric and devices on a remote fabric consisting of B-series or C-series switches. For a list of switches that are supported in a remote fabric, see the HP StorageWorks SN6000 Fibre Channel Switch Release Notes, and the HP StorageWorks SAN Design Reference Guide - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 27
a HP StorageWorks B-series or C-series SAN switch. For more detailed information, see the HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide, HP StorageWorks 8/20q and SN6000 Enterprise Fabric Management Suite User Guide, and the HP StorageWorks SN6000 Fibre Channel - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 28
as passwords that control read and write access to the switch. These strings are set at the factory to these well-known defaults and should be changed if SNMP is to be enabled. Otherwise, you risk unwanted access to the switch. The switch supports SNMP versions 1, 2, and 3. The default configuration - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 29
configuration, see the HP StorageWorks SN6000 Fibre Channel Switch Command Line Interface Guide. NOTE: If the same user account exists on a switch and its RADIUS server, that user can login with either password, but the authority and account expiration will always come from the switch database. IP - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 30
, and SMI-S. Use the CLI to configure SSH and SSL. For more information about SSH and SSL configuration, see the HP StorageWorks SN6000 Fibre Channel Switch Command Line Interface Guide. The SSL handshake process between the workstation and the switch involves the exchanging of certificates. These - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 31
storage arrays, managing HBAs and managing H-series switches. SSCM provides switch functions for day to day management activities such as, IP network configuration, administrative password control, SNMP setup, firmware upgrades, and implementation of HP best zoning practices (single initiator zoning - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 32
32 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 33
higher Hardware Hardware RJ-45 Ethernet port PCI-e slots for the HP StorageWorks PCI-e FC HBA CD-ROM drive (optional) RJ-45 Ethernet port RS-232 serial port (optional) PCI-e slots for the HP StorageWorks PCI-e FC HBA HP StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide 33 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 34
End User License Agreement (EULA) • One HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Rack-Mount Kit Quick Start Installation Instructions • One HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Quick Start Installation Instructions • One HP StorageWorks SN6000 Fibre Channel Switch (12 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 35
same AC supply circuit may overload that circuit or the AC supply wiring. Consider the power source capacity and the total power usage of all switches on the circuit. • Reliable grounding in the rack must be maintained. HP StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide 35 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 36
required items NOTE: The rack mount kit installation requires one technician. Locate the following items and set them aside: • SN6000 Fibre Channel Switch • 8/20q and SN6000 Fibre Channel Switch rack-mount kit • Smaller items, such as screws, ship in plastic bags in the kit. See Table 9. Required - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 37
on the front rail flanges in the holes between the two cage-nuts on each of the front vertical rack posts. Figure 15 Installing the switch and rail assembly HP StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide 37 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 38
5. Fasten each rail flange to the front of the rack using two M6 machine screws (Figure 16). Figure 16 Fastening the rail to the front of the rack 6. Fasten each slotted-rail end to the rear mounting bracket using a flat washer and a 1/4-20 hex nut (Figure 17). Figure 17 Fastening the rail to the - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 39
switch has all ports active. Configure the workstation NOTE: If you plan to use Simple SAN Connection Manager, QuickTools, or Enterprise Fabric Management Suite to manage the switch, proceed to "Apply power to the switch HP StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide 39 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 40
service: The cable must be rated at 10 Amps, meet the requirements of H05VV-F, and be approved by Verband der Elektrotechnik (VDE), SEMKO, and DEMKO. To power up a SN6000 Fibre Channel Switch The POST tests the condition of firmware, memories, data-paths, and switch logic circuitry. If the Heartbeat - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 41
will prompt you to set the switch IP address, administrator password, and default zoning when you first start that application. When the configuration is complete, proceed to "Cable devices to the switch" (page 43). HP StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide 41 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 42
the HP StorageWorks SN6000 Fibre Channel Switch Command Line Interface Guide. SN6000 FC Switch#> admin start SN6000 FC Switch (admin) #> set setup system 3. Open a Config Edit session and use the set config switch CLI command to modify the switch configuration. 4. When the configuration is complete - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 43
Suite, see the HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Enterprise Fabric Management Suite User Guide. • Using QuickTools to install firmware, page 44 • Using the CLI to install firmware, page 44 You can load and activate firmware upgrades on an operating switch without disrupting data - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 44
HP StorageWorks SN6000 Fibre Channel Switch Command Line Interface Guide. 1. Enter the following commands to download the firmware from a remote host to the switch, install the firmware, then reset the switch to activate the firmware. SN6000 FC Switch #> admin start SN6000 FC Switch #> firmware - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 45
. image unpack command result: Passed 5. A message will prompt you to reset the switch to activate the firmware. Use the hotreset command to attempt a non-disruptive activation. SN6000 FC Switch (admin) $>hotreset HP StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide 45 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 46
HP StorageWorks SN6000 Fibre Channel Switch Command Line Interface Guide. Configuring Call Home to HP Services (optional) Call Home to HP Services is supported for the SN6000 Fibre Channel Switch. • If you have already configured Call Home to HP Services for other HP products using Remote Support - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 47
(if so configured) and to HP Services through RSC. These applications, in turn, send the event message over the internet to HP Services. OSEM version1.4.5 and SIM 5.1 (which includes RSP version 5.05) are the minimum versions required to support SN6000 Fibre Channel Switch Call Home to HP Services - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 48
access to the server running SIM and RSC, and to the SN6000 Fibre Channel Switches. NOTE: OSEM can also be installed on the server that is used to run SIM and RSC. 3. To enable a switch to Call Home to HP Services, configure an SNMP trap in the switch using QuickTools or the CLI, as described in the - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 49
, see the HP StorageWorks SN6000 Fibre Channel Switch Command Line Interface Guide. 4. Configure the switches in OSEM by adding each SN6000 Fibre Channel Switch as a Managed System configured with System Type set to FC Switch and the IP address for the switch. For detailed instructions, see the - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 50
50 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 51
power source. Is the power source delivering the proper voltage? • Yes-Continue. • No-Make necessary repairs. If the condition remains, contact your authorized maintenance provider. HP StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide 51 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 52
error blink pattern and take the necessary actions. See "Heartbeat LED blink patterns" (page 52). Power-On self test diagnostics The switch performs a series of tests as part of its power-up procedure. The POST diagnostic program performs the following tests: • Checksum tests on the boot firmware - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 53
. 2. Consider the ambient air temperature near the switch and clearance around the switch. Make necessary corrections. If the condition remains, power down the switch and contact your authorized maintenance provider. HP StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide 53 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 54
• Security failure • A port configured as an F_Port or an FL_Port is connected to another switch • Conflicting domain IDs • Conflicting timeout values • Conflicting zone membership between active zone sets • Connection to a B-series or C-series switch Using QuickTools, review the event browser, and - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 55
connection count • Device login errors • Device logout errors • Loss-of-signal errors Port threshold alarm monitoring is disabled by default. For information about managing port threshold alarms, see the HP StorageWorks SN6000 Fibre Channel Switch Command Line Interface Guide. If the count for any - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 56
the following procedure: 1. Examine the alarm configuration for the associated error using the show config threshold CLI command. See the show config threshold CLI command in the HP StorageWorks SN6000 Fibre Channel Switch Command Line Interface Guide. Are the thresholds and sample window correct - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 57
the switch configuration in maintenance mode (option 5), page 59 • Remaking the file system in maintenance mode (option 6), page 59 • Resetting the switch in maintenance mode (option 7), page 59 • Updating the boot loader in maintenance mode (option 8), page 59 HP StorageWorks SN6000 Fibre Channel - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 58
firmware installation" (page 45) for an example of how to load the image file. When the download is complete, close the FTP session. 3. Establish a Telnet session with the switch using the default IP address 10.0.0.1. telnet 10.0.0.1 4. Enter the maintenance mode account name (prom) and password - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 59
about downloading files from the switch, see the HP StorageWorks SN6000 Fibre Channel Switch Command Line Interface Guide. Removing the switch configuration in maintenance mode (option 5) The Remove Switch Config option deletes all configurations from the switch except the default configuration - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 60
60 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 61
you can remove or install one of the power supplies while the switch is operating without disrupting service. The power supplies are also interchangeable; that is, the left and right power supplies are the same unit. HP StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide 61 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 62
NOTE: Both power supplies on the SN6000 Dual Power Supply Fibre Channel Switch must have the same air flow direction to prevent the switch from overheating. To avoid overheating, do not operate the switch with one power supply any longer than necessary. When removing or replacing a power supply, - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 63
2 AC receptacle Figure 24 Power supply installation The power supply in the SN6000 Single Power Supply Fibre Channel Switch can be removed and replaced, but as there is only one power the knurled fasteners by hand. HP StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide 63 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 64
64 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 65
/us/en/contact_us.html). To contact HP by phone, call: 1-800-HP-INVENT (1-800-474-6836). This service is available 24 hours a day, 7 days a week. For continuous quality improvement, calls may be recorded or monitored. HP StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide 65 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 66
SN6000 Stackable 8Gb 12-port Single Power FC Switch • Added support for the port activation license key Related information Documents In addition to this guide, see the following documents for this product: • HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Quick Start Installation Instructions - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 67
• HP StorageWorks 8/20q and SN6000 Fibre Channel Switch CIM Agent Reference Guide For the latest product information, including firmware, documentation, and supported SAN configurations, see the following HP website: http://www.hp.com/go/SN6000. Other HP websites For additional information, see the - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 68
68 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 69
and used in accordance with the instruction manual, may cause harmful interference to radio to open the laser device enclosure. There are no user-serviceable components inside. • Do not operate controls, make manual. HP StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide 69 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 70
Fibre Channel communications port. In the USA, the FO transceiver is certified as a Class 1 laser product conforming to the requirements contained in the Department of Health and Human Services equivalent may be located on the surface of the HP-supplied laser device or on the laser device installed - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 71
only if applicable- refer to the product label) Hewlett-Packard GmbH, HQ-TRE, Herrenberger Strasse 140, 71034 Boeblingen, Germany Japanese notice Korean notice Taiwan notice \ HP StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide 71 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 72
72 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 73
service tools. • Use a portable field service kit HP authorized reseller install the part. NOTE: For more information on static electricity, or for assistance with product installation, contact your HP authorized reseller. HP StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 74
74 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 75
and eight SFP ports are active. Additional ports can be activated in four port increments with the port activation license key. 24-port single and dual power supply models: Four XPAK ports and 20 SFP ports are active. HP StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide 75 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 76
Maximum 239 switches, depending on configuration. For the latest supported configurations, see the SAN Design Reference Guide available at http://www.hp.com/go/SANdesignguide. Maximum user ports > 475,000 ports depending on configuration. For the latest supported configurations, see the SAN Design - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 77
; 10/100 BASE-T cable Switch agent Allows a network management station to obtain configuration values, traffic information, and failure data pertaining to the Fibre Channels using SNMP through the Ethernet interface. HP StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide 77 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 78
kg (18 lbs.) Single power supply: 6.8 kg (15 lbs.) Electrical specifications Table 15 lists electrical specifications for the SN6000 Fibre Channel Switch. Table 15 Electrical specifications Specification Description Operating voltage Power source loading (maximum) Heat output (maximum) Circuit - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 79
True FDMIEntries DefaultDomainID 1,000 1 (0x Hex) DomainIDLock False SymbolicName SN6000 FC Switch R_A_TOV 10000 E_D_TOV 2000 PrincipalPriority 254 ConfigDescription Default Config InteropMode Standard HP StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide 79 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 80
Enter the show config port CLI command to display port configuration values. Table 18 Port configuration defaults Parameter Port Defaults AdminState Online LinkSpeed Ports 0-19: Auto; Ports 20-23: Auto PortType SymbolicName Ports 0-19: GL; Ports 20-23: G Port n, for ports 0-19 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 81
configuration Enter the show config zoning CLI command to display zoning configuration values. Table 20 Zoning configuration defaults Parameter Default MergeAutoSave True DefaultZone Allow DiscardInactive False HP StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 82
21 SNMP configuration defaults Parameter Default SNMPEnabled True Contact Location Description For AW575A and BK780A: HP StorageWorks SN6000 Stackable Single Power Supply Fibre Channel Switch For AW576A: HP StorageWorks SN6000 Stackable Dual - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 83
switch services configuration Enter the show setup services CLI command to display switch service configuration values. Table 22 Services configuration defaults Parameter Default > DNSSearchList5 HP StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide 83 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 84
10.0.0.254 Factory IP version 6 Ethernet configuration Enter the show setup system ipv6 CLI command to display the IP version 6 Ethernet configuration values. Table 25 IP version 6 Ethernet configuration defaults Parameter Default EthIPv6NetworkEnable True EthIPv6NetworkDiscovery - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 85
Enter the show config security CLI command to display security configuration values. Table 30 Security configuration defaults Parameter Default AutoSave True FabricBindingEnabled False PortBindingEnabled False HP StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide 85 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 86
Factory Call Home configuration Enter the show setup callhome CLI command to display call home configuration values. Table 31 Call Home service configuration defaults Parameters Default PrimarySMTPServerAddr 0.0.0.0 PrimarySMTPServerPort 25 PrimarySMTPServerEnabled False - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 87
Channel switch port that supports a connection to a single server or storage device. Fabric device management An interface by which device host bus adapters (HBAs) can be managed through the interface (FDMI) fabric. HP StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 88
Network Management Protocol (SNMP). FC port Fibre Channel port FL_Port Fabric loop port. A Fibre Channel switch port that supports a connection to up to 126 server or storage devices. Flash memory Memory on the switch that contains the switch control firmware. Frame Data unit consisting of - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 89
that uses the Fibre Channel industry standard NPIV to provide access to devices on a remote HP StorageWorks B-series or C-series fabric. User account An object stored on a switch that consists of an account name, password, authority level, and expiration date. User account security A component - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 90
90 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 91
76 port 14 security 29 factory defaults 59 feature licenses 22 Fibre Channel ports 12 protocols 75 Field Replaceable Unit 77 File Transfer Protocol account name 45 description 18 service 28 firmware description 43 HP StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide 91 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 92
over-temperature 53 P password file reset 59 maintenance mode 58 restore default 59 performance device 23 switch 20 planning 19 port binding 29 buffer credits 20 characteristics 75 diagnostics 54 Ethernet 15 fabric 14 Fibre Channel 12 generic 14 LEDs 13 maximum number of ports/users 76 number of 75 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 93
transparent routing 26 transparent routing port 14 two-switch stacking 23 U user account security 29 user interface 77 V vibration 78 voltage 78 W warning rack stability 66 web applet description 17 service 28 websites HP StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide 93 - HP SN6000 | HP StorageWorks SN6000 Fibre Channel Switch Installation and Referen - Page 94
HP documentation 67 HP storage 67 HP Subscriber's choice 66 workstation configuration 39 connecting 41 IP address 39 operating system 15 requirements 33 X XPAK port 12 Z zone conflict 55 definition 19 zone set active 19 definition 19 zoning database 20 hardware-enforced 19 limits 20 94
HP StorageWorks SN6000 Fibre Channel Switch
Installation and Reference Guide
This guide describes the HP StorageWorks SN6000 Fibre Channel Switch features and capabilities, planning
considerations, installation, diagnostics, and troubleshooting. This guide is intended for users who are responsible for
installing and servicing network equipment.
Part Number: 5697-0414
Published June 2010
Edition: 2