HP Scitex FB10000 Geffen TS Error 66115

HP Scitex FB10000 Manual

HP Scitex FB10000 manual content summary:

  • HP Scitex FB10000 | Geffen TS Error 66115 - Page 1
    Cooler - Small heater SSR fault FB10000 Error Messages Troubleshooting Error ID: 66115: Unified Cooler - Small heater SSR fault Error Severity: Error Possible Causes • Small heater CB is down • Small heater short-circuit • Ethernet line connection problem • Faulty C_H3 contactor • Faulty SSR_H1
  • HP Scitex FB10000 | Geffen TS Error 66115 - Page 2
    heater circuit breaker [CB-H1 trio] FB10000 Error Messages Troubleshooting Unified cooler electric panel CB_H1 3. If the error, the error message reappears, then the problem is not a short circuit in the heater but From this stage and on, only an HP certified electrician may perform the tests. 6.
  • HP Scitex FB10000 | Geffen TS Error 66115 - Page 3
    Error ID: 66115: Unified Cooler - Small heater SSR fault FB10000 Error Messages Troubleshooting 7. Ask a colleague to monitor the Small Heater SSR LED [SSR_H1] while you perform the following tests: When cooler is idle, the SSR should be OFF,
  • HP Scitex FB10000 | Geffen TS Error 66115 - Page 4
    Small heater SSR fault FB10000 Error Messages Troubleshooting 12. Repeat steps 7 disconnection or faulty OPC. 14. Restart the cooler using the Service Tools SW and repeat steps 7 and 8 while your If the OPC LED does not light in green, then the problem is in the OPC and you should replace it. 16.
  • HP Scitex FB10000 | Geffen TS Error 66115 - Page 5
    Error ID: 66115: Unified Cooler - Small heater SSR fault FB10000 Error Messages Troubleshooting 17. While cooler is on, use an Ammeter to measure the current in TB_DIS element - replace the small heater 18. If all these steps did not solve the problem, contact your HP regional specialist. 5
  • 1
  • 2
  • 3
  • 4
  • 5

Error ID: 66115: Unified Cooler - Small heater SSR fault
FB10000 Error Messages Troubleshooting
FB10000 Error Messages Troubleshooting
Error ID: 66115: Unified Cooler - Small heater SSR fault
Error Severity: Error
Possible Causes
Small heater CB is down
Small heater short-circuit
Ethernet line connection problem
Faulty C_H3 contactor
Faulty SSR_H1
Faulty BM_1 B&R module
Faulty OPC
Recommended Actions
1.
Open the circuit breaker flap cover in the cooler front.
Cooler electric panel flap