HP Scitex FB10000 Geffen TS Error 66316
HP Scitex FB10000 Manual
View all HP Scitex FB10000 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP Scitex FB10000 manual content summary:
- HP Scitex FB10000 | Geffen TS Error 66316 - Page 1
Voltage Guard is Opened FB10000 Error Message Troubleshooting Error ID: 66316 - UV - UV High Voltage Guard is Opened 66316 UV Inverter-Suction Alarm Failure in the extraction air system due to inverter fault For more details open the Troubleshooting guide Possible Causes • Q5 is - HP Scitex FB10000 | Geffen TS Error 66316 - Page 2
correct. Cabinet Extraction fan is not properly connected 1. Check that the extract fan is connected. 2. Check that there are no damaged pins in the plug. FB10000 Error Message Troubleshooting Top 2 - HP Scitex FB10000 | Geffen TS Error 66316 - Page 3
off the cabinet and wait for 30 seconds. 3. After that, using a voltmeter in continuity check mode, perform the following checks. FB10000 Error Message Troubleshooting Top 4. Open the cabinet and check the display in the inverter. Compare it with the following tables: Note: Fault detection codes - HP Scitex FB10000 | Geffen TS Error 66316 - Page 4
Error ID: 66316 - UV - UV High Voltage Guard is Opened FB10000 Error Message Troubleshooting Top 4 - HP Scitex FB10000 | Geffen TS Error 66316 - Page 5
Error ID: 66316 - UV - UV High Voltage Guard is Opened FB10000 Error Message Troubleshooting Top 5
Error ID: 66316 - UV – UV High Voltage Guard is Opened
FB10000 Error Message Troubleshooting
FB10000 Error Message Troubleshooting
Error ID: 66316 - UV – UV High Voltage Guard is Opened
66316 <Month, Day, Time>
UV Inverter-Suction Alarm
Failure in the extraction air system due to inverter fault
For more details open the
Troubleshooting guide
Possible Causes
•
Q5 is tripped
•
Cabinet Extraction fan is not properly connected
•
Motor windings are not properly connected
•
Frequency Inverter A5 and plug X5 are not properly connected
1