HP Scitex FB10000 Geffen TS Error 66118
HP Scitex FB10000 Manual
View all HP Scitex FB10000 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP Scitex FB10000 manual content summary:
- HP Scitex FB10000 | Geffen TS Error 66118 - Page 1
out of range FB10000 Error Message Troubleshooting FB10000 Error Message Troubleshooting Error ID: 66118 - Unified Cooler - Ambient temperature out of range 66118 Ambient temperature out of range. For more details open the Troubleshooting guide Possible Causes • Ambient - HP Scitex FB10000 | Geffen TS Error 66118 - Page 2
in site. 2. Proceed according to the instructions provided below. FB10000 Error Message Troubleshooting WARNING! High Voltage System! Do not touch any wiring while system is UP! From this stage and on, only an HP - HP Scitex FB10000 | Geffen TS Error 66118 - Page 3
Error ID: 66118 - Unified Cooler - Ambient temperature out of range FB10000 Error Message Troubleshooting Faulty Sensor 1. Replace Sensor (Call HP Service) 2. If all these steps did not solve the problem, contact your HP Regional Technical Specialist. 3
Error ID: 66118 - Unified Cooler - Ambient temperature out of range
FB10000 Error Message Troubleshooting
FB10000 Error Message Troubleshooting
Error ID: 66118 - Unified Cooler - Ambient temperature out of range
66118 <Month, Day, Time>
Ambient temperature out of range.
For more details open the
Troubleshooting guide
Possible Causes
•
Ambient temperature is above or below indicated site temperature
•
Faulty cable connection from sensor to Control Module
•
Faulty control module
•
Faulty sensor
1