  • HP Scitex FB10000 | Geffen TS Error 50221 - Page 1
    Troubleshooting FB10000 Error Messages Troubleshooting Error ID: 50221 - Motion - T Unable to Move - Fifth Pressure piston is not UP Error Message: 50221 T Unable to Move - Fifth Pressure piston is not UP Tap the Get Ready button. For more details open the Troubleshooting guide
  • HP Scitex FB10000 | Geffen TS Error 50221 - Page 2
    Error ID: 50221 - Motion - T Unable to Move - Fifth Pressure piston is not UP FB10000 Error Messages Troubleshooting Recommended actions Faulty Sensor 1. Move the ML table away from the machine and open the loader door. 2. Make sure that the sensors are well connected
  • HP Scitex FB10000 | Geffen TS Error 50221 - Page 3
    T Unable to Move - Fifth Pressure piston is not UP FB10000 Error Messages Troubleshooting Main valve 6-8 Bar Top Loading suction cups 4 Bar Unloading suction , the following steps can be done exclusively by a certified HP Service Engineer! 5. Remove the panel covering the loader pneumatic panel
  • HP Scitex FB10000 | Geffen TS Error 50221 - Page 4
    Error ID: 50221 - Motion - T Unable to Move - Fifth Pressure piston is not UP FB10000 Error Messages Troubleshooting Wiring 1. Make sure that the sensor is well connected to input #13 of the 8DI2 B&R module attached to the back of the dynamic frame. Top 4
  • HP Scitex FB10000 | Geffen TS Error 50221 - Page 5
    Error ID: 50221 - Motion - T Unable to Move - Fifth Pressure piston is not UP FB10000 Error Messages Troubleshooting 2. make sure that cable CX161-01440 is well connected to the pneumatic manifold on the dynamic frame Top 5
  • HP Scitex FB10000 | Geffen TS Error 50221 - Page 6
    Error ID: 50221 - Motion - T Unable to Move - Fifth Pressure piston is not UP FB10000 Error Messages Troubleshooting Top Dynamic Frame pneumatic manifold Cable CX161-01440 6
  • HP Scitex FB10000 | Geffen TS Error 50221 - Page 7
    Error ID: 50221 - Motion - T Unable to Move - Fifth Pressure piston is not UP FB10000 Error Messages Troubleshooting 3. Make sure that the manifold on the dynamic frame is functioning by activating the piston from the Control Tools Top Activate the piston from here 7
  • HP Scitex FB10000 | Geffen TS Error 50221 - Page 8
    Error ID: 50221 - Motion - T Unable to Move - Fifth Pressure piston is not UP 4. Make sure that the wire at BnR Module 7DO1, pin #21 is well connected FB10000 Error Messages Troubleshooting Top 8
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

Error ID: 50221 – Motion – T Unable to Move - Fifth Pressure piston is not UP
FB10000 Error Messages Troubleshooting
FB10000 Error Messages Troubleshooting
Error ID: 50221 – Motion – T Unable to Move - Fifth Pressure piston is not UP
Error Message:
50221 <Month, Day, Time>
T Unable to Move - Fifth Pressure piston is not UP
Tap the Get Ready button.
For more details open the
Troubleshooting guide
Possible Causes
Faulty Sensor
Mechanical Interference
Pneumatic Fault
Wiring
1