    main tank. FB10000 Error Messages Troubleshooting Error ID: 66033: IDS - Overflow in light cyan main tank. Error Severity: Critical Possible Causes Real overflow event in main ink tank - drain main ink tank No real ink overflow - wrong reading due to main tank floater sensor problem Real overflow
  • HP Scitex FB10000 | Geffen TS Error 66033 - Page 2
    Error ID: 66033: IDS - Overflow in light cyan main tank. Troubleshooting Flowchart FB10000 Error Messages Troubleshooting LC main tank overflow floater is mechanically stuck No Error ID: 66028: IDS - Overflow in LC main tank MM4331 (1MM3) B&R Module is faulty No Are
  • HP Scitex FB10000 | Geffen TS Error 66033 - Page 3
    Error ID: 66033: IDS - Overflow in light cyan main tank. FB10000 Error Messages Troubleshooting Recommended Actions Real Overflow event - Drain light cyan main ink tank 1. Attach a female CPC quick connector (PN CX145-06740) to a 40cm x0.8 cm diam. ink
  • HP Scitex FB10000 | Geffen TS Error 66033 - Page 4
    Error ID: 66033: IDS - Overflow in light cyan main tank. FB10000 Error Messages Troubleshooting Wiring path from main ink pump to MM4331 [1MM3] B&R module through cable CX161-03030 is disconnected Top Flowchart 4
  • HP Scitex FB10000 | Geffen TS Error 66033 - Page 5
    Error ID: 66033: IDS - Overflow in light cyan main tank. FB10000 Error Messages Troubleshooting The MM4331 B&R module [1MM3] is faulty - replace module Each B&R control module comprises three components: Base, Bus Unit (BU), and Terminal block (12 PINS) as shown
  • HP Scitex FB10000 | Geffen TS Error 66033 - Page 6
    IDS - Overflow in light cyan main tank. FB10000 Error Messages Troubleshooting Note: This procedure takes up to two minutes. the new module. 7. If none of the above steps solved the problem, contact your HP service specialist. The light cyan main tank overflow floater sensor is faulty Assuming
  • HP Scitex FB10000 | Geffen TS Error 66033 - Page 7
    Error ID: 66033: IDS - Overflow in light cyan main tank. FB10000 Error Messages Troubleshooting Top Flowchart 5. Check wiring path continuity from floater to B&R control module along cable CX161-02860 (from J4 Light cyan panel to DI9371 [1DI4]. 7
  • HP Scitex FB10000 | Geffen TS Error 66033 - Page 8
    Error ID: 66033: IDS - Overflow in light cyan main tank. FB10000 Error Messages Troubleshooting DI9371 B&R module [1DI4] to which light cyan main tank overflow sensor is connected through cable CX161-02860 Top Flowchart The DI9371 [1DI4] B&R module is faulty -
  • HP Scitex FB10000 | Geffen TS Error 66033 - Page 9
    Error ID: 66033: IDS - Overflow in light cyan main tank. FB10000 Error Messages Troubleshooting Top Flowchart 2. Before replacing a module BU, turn the machine power OFF. 3. Release the configure the new module. If none of the above steps solved the problem, contact your HP service specialist. 9
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9

Error ID: 66033: IDS - Overflow in light cyan main tank.
FB10000 Error Messages Troubleshooting
FB10000 Error Messages Troubleshooting
Error ID: 66033: IDS - Overflow in light cyan main tank.
Error Severity:
Critical
Possible Causes
Real overflow event in main ink tank - drain main ink tank
No real ink overflow – wrong reading due to main tank floater sensor problem
Real overflow due to main ink pump stuck on continuous pumping
No real ink overflow – wrong reading due to faulty MM4331 (1MM3) B&R control module
No real ink overflow – wrong reading due to faulty DI9371 (1DI4) B&R module
No real ink Overflow – wrong reading due to wiring disconnection
Troubleshooting Flowchart
1