HP Scitex FB10000 Geffen TS Error 50071

HP Scitex FB10000 Manual

HP Scitex FB10000 manual content summary:

  • HP Scitex FB10000 | Geffen TS Error 50071 - Page 1
    : 50071 - Motion - X-Axis unable to move FB10000 Error Messages Troubleshooting Error ID: 50071 - Motion - X-Axis unable Loader and Unloader beams are not in their lower position For more details open the Troubleshooting guide Possible Causes • Bath is not up and not in its place • Wiper is not
  • HP Scitex FB10000 | Geffen TS Error 50071 - Page 2
    Error ID: 50071 - Motion - X-Axis unable to move Recommended actions Verify that the waste bath is in its place at that it is up Verify that the Wiper is at its Home position Verify that the L&U axes are at their lower limits Perform Get Ready FB10000 Error Messages Troubleshooting Top 2
  • 1
  • 2

Error ID: 50071 - Motion – X-Axis unable to move
FB10000 Error Messages Troubleshooting
FB10000 Error Messages Troubleshooting
Error ID: 50071 - Motion – X-Axis unable to move
Error Message:
50071 <Month, Day, Time>
X-Axis unable to move. Verify that the waste bath is up and in its
cradle, vacuum knife is at home (operator side), and the Loader and
Unloader beams are not in their lower position For more details open
the
Troubleshooting guide
Possible Causes
Bath is not up and not in its place
Wiper is not at home position
L&U axes are not at their lower limits
1