  • HP Scitex FB10000 | Geffen TS Error 67014 - Page 1
    Error ID: 67014: Safety - Unloader door is open FB10000 Error Messages Troubleshooting FB10000 Error Messages Troubleshooting Error ID: 67014: Safety - Unloader door is open Error Severity: Critical Possible Causes • The Unloader door is open • The Unloader door interlock is not properly
  • HP Scitex FB10000 | Geffen TS Error 67014 - Page 2
    Error ID: 67014: Safety - Unloader door is open Troubleshooting Flowchart FB10000 Error Messages Troubleshooting Troubleshooting Flowchart for error messages 67014 Valid for 67013 - 67022 Safety interlocks Check the X20SI9100 pulses ouput Yes Is there More than 1 interlock OFF in this
  • HP Scitex FB10000 | Geffen TS Error 67014 - Page 3
    67014: Safety - Unloader door is open FB10000 Error Messages Troubleshooting Recommended Actions The Unloader door is open 1. touch any wiring while system is UP! From this stage and on, only an HP certified electrician may perform the tests. The interlock is faulty or cable CX161-03490 connecting
  • HP Scitex FB10000 | Geffen TS Error 67014 - Page 4
    Error ID: 67014: Safety - Unloader door is open FB10000 Error Messages Troubleshooting Door closed correct state Door open correct state 4. If the case, replace the receiver. 10. If the problem persists after replacing the receiver, this indicates that the safety B&R module X20 SI9100 might be faulty.
  • HP Scitex FB10000 | Geffen TS Error 67014 - Page 5
    Error ID: 67014: Safety - Unloader door is open FB10000 Error Messages Troubleshooting The B&R module is faulty 1. Measure 2TBM-10(3) and 2TBM-12(3) voltage via 24V_gnd (24V_0). You should get 8-20V this means that the entire route is
  • HP Scitex FB10000 | Geffen TS Error 67014 - Page 6
    ID: 67014: Safety - Unloader door is open FB10000 Error Messages Troubleshooting Step 1: Press the two latches (1) on top Set the Safety PLC selector to 1 (one new module) and press the Enter button to instruct the Safety PLC to configure the new module. Upon completion, the MXCHG LED will blink
  • HP Scitex FB10000 | Geffen TS Error 67014 - Page 7
    ID: 67014: Safety - Unloader door is open FB10000 Error Messages Troubleshooting 9. If the MXCHG LED continues blinking orange single B&R PLC configuration guide, on page 4 for further instructions. 11. If none of the above steps solved the problem, contact your HP service specialist. Note: The
  • HP Scitex FB10000 | Geffen TS Error 67014 - Page 8
    Error ID: 67014: Safety - Unloader door is open 2SDI1 Digital Input 1 12.WARN FB10000 Error Messages Troubleshooting B&R Safety Processor PLC Configuration link is set as Station 6 2 S DI 2 - SI 9 (15) 8
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

Error ID: 67014: Safety – Unloader door is open
FB10000 Error Messages Troubleshooting
FB10000 Error Messages Troubleshooting
Error ID: 67014: Safety – Unloader door is open
Error Severity:
Critical
Possible Causes
The Unloader door is open
The Unloader door interlock is not properly aligned
The interlock is faulty or the cable connecting it to the B&R module is disconnected or damaged
The B&R module is faulty
Troubleshooting Flowchart
1