    is full - Replace waste container (maintenance not allowed) FB10000 Error Message Troubleshooting FB10000 Error Message Troubleshooting Error ID: 1102: IDS - Waste ink container is (regular workflow) • Waste container Load cell needs calibration (HP engineer only) • Spider board is faulty
  • HP Scitex FB10000 | Geffen TS Error 1102 - Page 2
    full - Replace waste container (maintenance not allowed) FB10000 Error Message Troubleshooting Recommended Actions Waste Container is full - Replace container calibration or there is a problem with the Spider board. Waste container Load cell needs recalibration (HP Service Engineer only) 1. If
  • HP Scitex FB10000 | Geffen TS Error 1102 - Page 3
    (maintenance not allowed) FB10000 Error Message Troubleshooting Top 2. If the problem persists after the reset, you may need to replace the Spider board. 3. Please contact CallmeHP for assistance. Note: Replacing the Spider board must be done by an HP Service Engineer and requires recalibrating
  • 1
  • 2
  • 3

Error ID: 1102: IDS - Waste ink container is full – Replace waste container (maintenance not allowed)
FB10000 Error Message
Troubleshooting
FB10000 Error Message Troubleshooting
Error ID: 1102: IDS - Waste ink container is full – Replace waste container (maintenance not allowed)
Error Severity:
Critical
This error appears when the Moby system detects that the waste tank is full. In this case, print head maintenance cannot be performed.
Possible Causes
Waste container is full – Replace container (regular workflow)
Waste container Load cell needs calibration
(HP engineer only)
Spider board is faulty
(HP engineer only)