HP Scitex FB10000 Geffen TS Error 66048
HP Scitex FB10000 Manual
View all HP Scitex FB10000 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP Scitex FB10000 manual content summary:
- HP Scitex FB10000 | Geffen TS Error 66048 - Page 1
Error ID: 16048: Light Magenta cross valve back failed to open FB10000 Error Messages Troubleshooting FB10000 Error Messages Troubleshooting Error ID: 16048: Light Magenta cross valve back failed to open Error Severity: Critical Possible Causes • Cross valves do not receive 24V supply • Feeding - HP Scitex FB10000 | Geffen TS Error 66048 - Page 2
Error ID: 16048: Light Magenta cross valve back failed to open Troubleshooting Flowchart FB10000 Error Messages Troubleshooting Top Flowchart 2 - HP Scitex FB10000 | Geffen TS Error 66048 - Page 3
Error ID: 16048: Light Magenta cross valve back failed to open FB10000 Error Messages Troubleshooting Recommended Actions WARNING! High Voltage System! Do not touch any wiring while system is UP! From this stage and on, only an HP certified electrician may perform the tests. Air supply to cross - HP Scitex FB10000 | Geffen TS Error 66048 - Page 4
failed to open FB10000 Error Messages Troubleshooting One or more change state - with the cross valves in the closed position, manually hide & reveal the optic sensor to see if it changes be replaced. Top 2. If the valve is ok and the problem persists, check the wiring to the Cross Valve. 3. If it - HP Scitex FB10000 | Geffen TS Error 66048 - Page 5
valve back failed to open One of the B&R modules 6DI1, 6DI2, 6DI3 on the bridge is faulty FB10000 Error Messages Troubleshooting 1. If only one sensor shows error this might be a sensor problem. 2. If two sensors belonging to following couples (LC+LM , Y+C , M+K) shows error, this might indicate - HP Scitex FB10000 | Geffen TS Error 66048 - Page 6
Error ID: 16048: Light Magenta cross valve back failed to open FB10000 Error Messages Troubleshooting B&R module 1DO2 in LEC is faulty Cable CX161-03230 connects J11 in the J1 in the bridge pneumatic panel located under the bridge in the - HP Scitex FB10000 | Geffen TS Error 66048 - Page 7
Error ID: 16048: Light Magenta cross valve back failed to open FB10000 Error Messages Troubleshooting 1. If none of the cross valves respond, check the central 24V supply path from the LEC to the cross-valves. 2. Check also wiring and connections.
Error ID: 16048: Light Magenta cross valve back failed to open
FB10000 Error Messages Troubleshooting
1
FB10000 Error Messages Troubleshooting
Error ID: 16048: Light Magenta cross valve back failed to open
Error Severity:
Critical
Possible Causes
•
Cross valves do not receive 24V supply
•
Feeding valve in Bridge Pneumatic panel does not supply air pressure to cross valves
•
Main Valve in Main Pneumatic panel does not supply air pressure to feeding valve in bridge pneumatic panel
•
One or more cross valve(s) are mechanically stuck
•
One or more cross valve sensor(s) is faulty
•
B&R module 1DO2 in LEC is faulty
•
One of the B&R modules 6DI1, 6DI2, 6DI3 on the bridge is faulty
Troubleshooting Flowchart