    Error ID: 66055: Black cross valve front failed to close FB10000 Error Messages Troubleshooting FB10000 Error Messages Troubleshooting Error ID: 66055: Black cross valve front failed to close Error Severity: Critical Possible Causes • Cross valves sensors do not receive 24V supply • Feeding valve
  • HP Scitex FB10000 | Geffen TS Error 66055 - Page 2
    Error ID: 66055: Black cross valve front failed to close Troubleshooting Flowchart FB10000 Error Messages Troubleshooting Top Flowchart 2
  • HP Scitex FB10000 | Geffen TS Error 66055 - Page 3
    Error ID: 66055: Black cross valve front failed to close FB10000 Error Messages Troubleshooting Recommended Actions WARNING! High Voltage System! Do not touch any wiring while system is UP! From this stage and on, only an HP certified electrician may perform the tests. Air supply to cross valves
  • HP Scitex FB10000 | Geffen TS Error 66055 - Page 4
    failed to close FB10000 Error Messages Troubleshooting One or more change state - with the cross valves in the closed position, manually hide & reveal the optic sensor to see if it changes be replaced. Top 2. If the valve is ok and the problem persists, check the wiring to the Cross Valve. 3. If it
  • HP Scitex FB10000 | Geffen TS Error 66055 - Page 5
    valve front failed to close One of the B&R modules 6DI1, 6DI2, 6DI3 on the bridge is faulty FB10000 Error Messages Troubleshooting 1. If only one sensor shows error this might be a sensor problem. 2. If two sensors belonging to following couples (LC+LM ,
Y+C , M+K) shows error, this might indicate
  • HP Scitex FB10000 | Geffen TS Error 66055 - Page 6
    Error ID: 66055: Black cross valve front failed to close FB10000 Error Messages Troubleshooting B&R module 1DO2 in LEC is faulty Cable CX161-03230 connects J11 in the J1 in the bridge pneumatic panel located under the bridge in the
  • HP Scitex FB10000 | Geffen TS Error 66055 - Page 7
    Error ID: 66055: Black cross valve front failed to close FB10000 Error Messages Troubleshooting 1. If none of the cross valves respond, check the central 24V supply path from the LEC to the cross-valves. 2. Check also wiring and connections.
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

Error ID: 66055: Black cross valve front failed to close
FB10000 Error Messages Troubleshooting
1
FB10000 Error Messages Troubleshooting
Error ID: 66055: Black cross valve front failed to close
Error Severity:
Critical
Possible Causes
Cross valves
sensors
do not receive 24V supply
Feeding valve in Bridge Pneumatic panel does not supply air pressure to cross valves
Main Valve in Main Pneumatic panel does not supply air pressure to feeding valve in bridge pneumatic panel
One or more cross valve(s) are mechanically stuck
One or more cross valve sensor(s) is faulty
B&R module 1DO2 in LEC is faulty
One of the B&R modules 6DI1, 6DI2, 6DI3 on the bridge is faulty
Troubleshooting Flowchart