HP Scitex FB10000 Geffen TS Error 50034

HP Scitex FB10000 Manual

HP Scitex FB10000 manual content summary:

  • HP Scitex FB10000 | Geffen TS Error 50034 - Page 1
    Error Message Troubleshooting FB10000 Error Message Troubleshooting Error ID: 50034 - Motion - T-Axis Unable to Find Forward Positive Limit (Lift side) 50034 T-Axis Unable to Find Forward Positive Limit (Lift side). For more details open the Troubleshooting guide Possible Causes
  • HP Scitex FB10000 | Geffen TS Error 50034 - Page 2
    Actions POT Sensor Error 1. Open the Control Tools application in the T-Loading Unloading module tab. 2. Check the POT Sensor-related indications. FB10000 Error Message Troubleshooting Top 3. Verify that the POT Sensor indicator for T motor is OFF (Gray). 4. If it is ON, check if the sensor is
  • HP Scitex FB10000 | Geffen TS Error 50034 - Page 3
    Axis Unable to Find Forward Positive Limit (Lift side) FB10000 Error Message Troubleshooting 5. If the sensor is disconnected, connect it. 6. If the sensor is faulty, replace it. Wiring Error 1. Check the wiring path from the T-axis HP sensor to the corresponding B&R module described in the figure
  • 1
  • 2
  • 3

Error ID: 50034 - Motion – T-Axis Unable to Find Forward Positive Limit (Lift side)
FB10000 Error Message Troubleshooting
FB10000 Error Message Troubleshooting
Error ID: 50034 - Motion – T-Axis Unable to Find Forward Positive Limit (Lift side)
50034 <Month, Day, Time>
T-Axis Unable to Find Forward Positive Limit (Lift side).
For more details open the
Troubleshooting guide
Possible Causes
POT Sensor error
Wiring error
1