HP Scitex FB10000 Geffen TS Error 67009

HP Scitex FB10000 Manual

HP Scitex FB10000 manual content summary:

  • HP Scitex FB10000 | Geffen TS Error 67009 - Page 1
    Error ID: 67009: Safety - Bridge front door is open. FB10000 Error Messages Troubleshooting Error ID: 67009: Safety - Bridge front door is open. Error Severity: Critical Possible Causes • The bridge front door is open • The bridge front door interlock
  • HP Scitex FB10000 | Geffen TS Error 67009 - Page 2
    Error ID: 67009: Safety - Bridge front door is open. Troubleshooting Flowchart Troubleshooting Flowchart for error messages 67013 - 67022 Safety interlocks Check the X20SI9100 pulses Yes Replace interlock or interlock wiring Replace the faulty X20SI9100 module 2 Troubleshooting Top Flowchart
  • HP Scitex FB10000 | Geffen TS Error 67009 - Page 3
    67009: Safety - Bridge front door is open. Troubleshooting Flowchart Recommended Actions The bridge front door is open Do not touch any wiring while system is UP! From this stage and on, only an HP certified electrician may perform the tests. The interlock or cable CX161-03430 connecting it to the
  • HP Scitex FB10000 | Geffen TS Error 67009 - Page 4
    Error ID: 67009: Safety - Bridge front door is open. Troubleshooting Door closed correct state Door open correct state 4. If the this is the case, replace the receiver. 10. If the problem persists even after replacing the receiver, this indicates that the safety B&R module X20 SI9100 is faulty.
  • HP Scitex FB10000 | Geffen TS Error 67009 - Page 5
    Error ID: 67009: Safety - Bridge front door is open. Troubleshooting The B&R module is faulty 1. Measure 2TBM6(2) and 2TBM8(2) voltage via 24V_gnd (24V_0). You should get 8-20V this means that the entire route is ok and
  • HP Scitex FB10000 | Geffen TS Error 67009 - Page 6
    Plug the two TBs (2) back into the BU (3) until you hear a click. Troubleshooting 7. Turn the machine on and configure the B&R Safety PLC to recognize and set selector to 1 (one new module) and press the Enter button to instruct the Safety PLC to configure the new module. Upon completion, the MXCHG
  • HP Scitex FB10000 | Geffen TS Error 67009 - Page 7
    ID: 67009: Safety - Bridge front door is open. Troubleshooting 9. If the MXCHG LED continues blinking orange single pulse detailed B&R PLC configuration guide, on page 4 for further instructions. 11. If none of the above steps solved the problem, contact your HP service specialist. Note: The
  • HP Scitex FB10000 | Geffen TS Error 67009 - Page 8
    Error ID: 67009: Safety - Bridge front door is open. Troubleshooting B&R Safety Processor - PLC Configuration link is set as Station 6 Top Flowchart 2 S DI 2 - SI 19 (14) 8
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

Error ID: 67009: Safety - Bridge front door is open.
FB10000 Error Messages Troubleshooting
FB10000 Error Messages Troubleshooting
Error ID: 67009: Safety - Bridge front door is open.
Error Severity:
Critical
Possible Causes
The bridge front door is open
The bridge front door interlock is not properly aligned
The bridge front door interlock or the cable connecting it to the B&R module are faulty
The B&R module is faulty
Troubleshooting Flowchart