    Error ID: 67019: Safety - Front manual loading flap is down FB10000 Error Messages Troubleshooting FB10000 Error Messages Troubleshooting Error ID: 67019: Safety - Front manual loading flap is down Error Severity: Critical Possible Causes • Front manual loading flap is down • Interlocks connecting
  • HP Scitex FB10000 | Geffen TS Error 67019 - Page 2
    Error ID: 67019: Safety - Front manual loading flap is down Troubleshooting Flowchart Error message (67019) Front manual loading flap is down FB10000 Error Messages Troubleshooting Lift the loading flap and press the blue Yes reset button Is front loading flap physically down ? No
  • HP Scitex FB10000 | Geffen TS Error 67019 - Page 3
    Error ID: 67019: Safety - Front manual loading flap is down FB10000 Error Messages Troubleshooting Recommended Actions Front manual loading flap is lowered 1. Lift the front loading flap up. 2. while system is UP! From this stage and on, only an HP certified electrician may perform the tests.
  • HP Scitex FB10000 | Geffen TS Error 67019 - Page 4
    67019: Safety - Front manual loading flap is down FB10000 Error Messages Troubleshooting The interlock is faulty or flap should be down. • If all of LEDs are turned off, this might indicate a connection problem between the B&R PLC and the Safety B&R module [X20SI9100]. • If the LEDS do not behave
  • HP Scitex FB10000 | Geffen TS Error 67019 - Page 5
    Error ID: 67019: Safety - Front manual loading flap is down FB10000 Error Messages Troubleshooting 7. Check the yellow coaxial cable connecting the case, replace the receiver. 12. If the problem persists after replacing the receiver, this indicates that the safety B&R module X20 SI9100 might be
  • HP Scitex FB10000 | Geffen TS Error 67019 - Page 6
    Error ID: 67019: Safety - Front manual loading flap is down FB10000 Error Messages Troubleshooting Safety B&R Module is faulty - Replace module 1. Turn the machine on. 2. As a last check before replacing the B&R module, measure the voltage on the TBs Test points
  • HP Scitex FB10000 | Geffen TS Error 67019 - Page 7
    manual loading flap is down FB10000 Error Messages Troubleshooting Top Flowchart 7. Set the Safety PLC selector to 1 (one new module) and press the Enter button to instruct guide, on page 4 for further instructions. 10. If none of the above steps solved the problem, contact your HP service specialist.
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

Error ID: 67019: Safety - Front manual loading flap is down
FB10000 Error Messages Troubleshooting
FB10000 Error Messages Troubleshooting
Error ID: 67019: Safety - Front manual loading flap is down
Error Severity:
Critical
Possible Causes
Front manual loading flap is down
Interlocks connecting flap are misaligned
Interlock is faulty or cable CX161-03540 connecting interlock and B&R module is disconnected or damaged
Safety B&R module is faulty
Troubleshooting Flowchart