HP Scitex FB10000 Geffen TS Error 66062

HP Scitex FB10000 Manual

HP Scitex FB10000 manual content summary:

  • HP Scitex FB10000 | Geffen TS Error 66062 - Page 1
    to fill the Magenta secondary tank (timed out) FB10000 Error Message Troubleshooting FB10000 Error Message Troubleshooting Error ID: 60062 - IDS - Unable to cabinet. If the error persists go to Troubleshooting guide Note: Before starting to troubleshoot this error, please consult the machine log
  • HP Scitex FB10000 | Geffen TS Error 66062 - Page 2
    Error ID: 60062 - IDS - Unable to fill the Magenta secondary tank (timed out) FB10000 Error Message Troubleshooting Top 2
  • HP Scitex FB10000 | Geffen TS Error 66062 - Page 3
    Error ID: 60062 - IDS - Unable to fill the Magenta secondary tank (timed out) FB10000 Error Message Troubleshooting 3
  • HP Scitex FB10000 | Geffen TS Error 66062 - Page 4
    Error ID: 60062 - IDS - Unable to fill the Magenta secondary tank (timed out) FB10000 Error Message Troubleshooting Recommended actions Top Magenta ink tubing to secondary tank is obstructed 1. Inspect the tubing along the route of the Magenta ink from the Main ink
  • HP Scitex FB10000 | Geffen TS Error 66062 - Page 5
    Error ID: 60062 - IDS - Unable to fill the Magenta secondary tank (timed out) FB10000 Error Message Troubleshooting Magenta 5 Micron ink filter is clogged 1. Replace the 5 micron Magenta ink filter. 2. If the error persists, check the Magenta 3 ways switching valve for fault 5
  • HP Scitex FB10000 | Geffen TS Error 66062 - Page 6
    60062 - IDS - Unable to fill the Magenta secondary tank (timed out) FB10000 Error Message Troubleshooting Magenta secondary tank feeding pump or wiring is faulty 1. If the corresponding B&R 1. Replace the valve if faulty. 2. If the error persists, contact callme@hp for specialist assistance. Top 6
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6

Error ID: 60062 – IDS – Unable to fill the Magenta secondary tank (timed out)
FB10000 Error Message Troubleshooting
FB10000 Error Message Troubleshooting
Error ID: 60062 – IDS – Unable to fill the Magenta secondary tank (timed out)
Error Message:
66062
<Month, Day, Time>
IDS - Unable to fill the Magenta secondary tank (timed out)
Check the secondary tank pump in the ink cabinet.
If the error persists go to
Troubleshooting guide
Note: Before starting to troubleshoot this error, please consult the machine log for other messages that appear in the log and look for hints that
may lead you to the source of the current error, for instance, which components are mentioned in the string.
Possible Causes
Magenta ink tubing to secondary ink tank is obstructed
B&R did not send the command to the Magenta secondary tank feeding pump
Magenta 5 micron ink filter is clogged
Magenta
secondary tank feeding pump is faulty
Magenta 3 Way-switching valve is faulty