HP StorageWorks 1510i HP StorageWorks 1510i Modular Smart Array maintenance an
HP StorageWorks 1510i - Modular Smart Array Manual
View all HP StorageWorks 1510i manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks 1510i manual content summary:
- HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 1
HP StorageWorks 1510i Modular Smart Array maintenance and service guide Part number: 383072-002 Second edition: May 2008 - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 2
of any kind and is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 3
Contents About this guide 7 Intended audience 7 Prerequisites 7 Related documentation 7 Document conventions and symbols 8 Rack stability 9 HP technical support 9 Customer self repair 9 Subscription service 9 HP websites 9 Documentation feedback 10 1 Illustrated parts list 11 2 Specifi - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 4
Returning the defective component 32 Recommended tools 33 Warnings and precautions 33 Electrostatic discharge information 33 Grounding methods 33 Equipment symbols 34 Weight warning 35 Rack warnings and precautions 35 Device warnings and precautions 36 Determining whether a component is hot - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 5
75 Finnish notice 76 French notice 76 German notice 76 Greek notice 76 Hungarian notice 77 Italian notice 77 1510i Modular Smart Array maintenance and service guide 5 - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 6
Latvian notice 77 Lithuanian notice 78 Polish notice 78 Portuguese notice 78 Slovakian notice 78 Slovenian notice 79 Spanish notice 79 Swedish notice 79 Index 81 6 - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 7
1510i Modular Smart Array maintenance and service guide • HP StorageWorks 1510i Modular Smart Array Command Line Interface user guide • HP StorageWorks Storage Management Utility user guide These documents are on the MSA1510i Support CD, available on the MSA1510i support page: http://www.hp.com/go - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 8
iSCSI Naming and Discovery • RFC number 4171: Internet Storage Name Service (iSNS) • RFC number 2608: Service Location Protocol (SLP) • RFC number 3927: IPv4 Link-Local IMPORTANT: Provides clarifying information or specific instructions. NOTE: Provides additional information. 8 About this guide - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 9
more than one component is extended. HP technical support For worldwide technical support information, see the HP support website: http://www.hp.com/support. Before contacting HP, collect the following information: : • http://www.hp.com 1510i Modular Smart Array maintenance and service guide 9 - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 10
http://www.hp.com/support/manuals • http://www.hp.com/support/downloads Documentation feedback HP welcomes your feedback. To make comments and suggestions about product documentation, please send a message to [email protected]. All submissions become the property of HP. 10 About this guide - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 11
list for the HP StorageWorks 1510i Modular Smart Array (MSA1510i). Item Description Service replacement module part number Standard shipping configuration items: 1 Power supply modules Optional Mandatory Optional Optional Mandatory 1510i Modular Smart Array maintenance and service guide 11 - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 12
items not illustrated: AC power cords Contact HP Support Contact your HP Authorized Reseller Mandatory Custom serial cable for you, this may be done at no additional charge under the type of warranty service designated for your product. No - Parts for which customer self repair is not available - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 13
• Power supply module specifications NOTE: For additional information on components and their part numbers, see Illustrated parts list. 1510i Modular Smart Array maintenance and service guide 13 - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 14
Chassis specifications Parameter Value Height 8.79 cm (3.46 in) Width 48.41 cm (19.06 in) Depth 61.77 cm (24.32 in) Weight 24.95 kg (55 lb) Input voltage requirements Rated input voltage 100 to 240 VAC Rated input frequency 50 Hz to 60 Hz Rated input current 6.4A Max, 1A typical - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 15
fications Parameter Height Width Depth Weight Value 7.7 cm (3.0 in) 6.4 cm (2.5 in) 32.0 cm (12.6 in) 1.80 kg (3.96 lb) 1510i Modular Smart Array maintenance and service guide 15 - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 16
16 Specifications - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 17
an additional controller (controller slot 2) 4. MSA1510i controller (controller slot 1) 5. Controller LCD message display panel 6. Controller LCD panel push buttons 1510i Modular Smart Array maintenance and service guide 17 - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 18
Rear view 1. 2-Port Ethernet iSCSI module (for the controller in slot 1) 2. Chassis slot diagram 3. Blank for additional 2-Port Ethernet iSCSI module (for the controller in slot 2) 4. Power supply module 2 5. Power supply module 1 6. SCSI I/O module (bus 0) 7. Blank for additional SCSI I/O module ( - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 19
. The power is off. The system is powered on. The system is in standby mode. The power is off. 1510i Modular Smart Array maintenance and service guide 19 - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 20
of the power supply and some internal circuitry remain active. To remove the power completely, disconnect all power cords from the device. For instructions, see "Powering off the MSA1510i" on page 38. Controller LEDs During normal runtime, the array controller has 18 LEDs that indicate controller - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 21
drive LEDs Each SCSI hard drive has three LEDs. The following figure and table describe their locations and meanings. 1510i Modular Smart Array maintenance and service guide 21 - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 22
is being accessed in one of the following ways: • The hard drive has been selected for identification in HP-SIM, MSA-CLI, or other supported management utility. • The hard drive is being upgraded. Do not remove the hard drive. Removing a hard drive at this time can cause data loss in - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 23
(1 possible. Hz) Off Off The drive is offline, a spare, or not configured as part of an array. 1510i Modular Smart Array maintenance and service guide 23 - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 24
Slot diagram LEDs Located on the rear of the MSA, the slot diagram provides information about MSA modules. 1. 2-Port Ethernet iSCSI module (for the controller in slot 2) 2. SCSI I/O module (bus 3) 3. SCSI I/O module (bus 2) 4. Fan module 1 5. Fan module 2 6. 2-Port Ethernet iSCSI module (for the - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 25
the network is established, the status is good, and there is activity on network. There is no network activity. 1510i Modular Smart Array maintenance and service guide 25 - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 26
Fan module LEDs Each fan module has one bi-color LED. This LED can be illuminated with either a green or amber color. The following figure and table describes their locations and meanings. Item Name 1 Status 2 Fault Condition Solid Off Blinking Color Green - Amber Meaning The power is on. The - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 27
. The power is off. There is activity on this SCSI module. There is no activity on this SCSI module. 1510i Modular Smart Array maintenance and service guide 27 - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 28
Power supply module LEDs The power supply uses a single bi-color LED to indicate status. This LED can be illuminated with either a green or amber color. The following figure and table describes their locations and meanings. Item Name 1 Status 2 Fault Condition Solid Off Blinking Color Green - - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 29
4 Available diagnostic tools The following is a partial list of tools that are supported for use with the MSA: • Storage Management Utility (SMU) overview • MSA Command Line Interface (MSA and integrate management data from HP and 1510i Modular Smart Array maintenance and service guide 29 - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 30
third-party devices. HP-SIM reports hardware fault conditions (both failure and pre-failure) and collects data for reporting and graphing. HP-SIM also provides base-level management of HP clients, printers, and selected storage. HP recommends using HP-SIM to monitor the performance of your Windows, - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 31
statements. • Verifying component failure - Before replacing a component, confer with HP technical support to verify that the hardware component has failed and that you are authorized to replace replacement component is operating properly. 1510i Modular Smart Array maintenance and service guide 31 - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 32
defective parts replacement. If, during the diagnosis period, HP (or HP service providers or partners) identifies that the repair can be accomplished by the permits. If assistance is required, you can call the HP Technical Support Center, and a technician will help you over the telephone. HP - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 33
the Printed Circuit Board (PCB) side down. • Use conductive field service tools. Grounding methods There are several methods for grounding. Use one or or dissipating floor mats. • Use conductive field service tools. • Use a portable field service kit with a folding static-dissipating work mat. 1510i Modular - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 34
enclosed surface or area of the equipment marked with these symbols indicates the presence of electrical shock hazards. Enclosed area contains no operator serviceable parts. To reduce the risk of injury from electrical shock hazards, do not open this enclosure. WARNING! Any RJ-45 receptacle marked - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 35
health and safety requirements and guidelines for manual material handling. • Get help to lift in aligning the rails while the other two support the device. Rack warnings and precautions Ensure that and warnings included in the installation instructions. WARNING! To reduce the risk service guide 35 - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 36
in the procedures in the product documentation. All troubleshooting and repair procedures are detailed to allow only by individuals who are qualified in servicing computer equipment, knowledgeable about the procedures safety requirements and guidelines for manually handling material. CAUTION: Protect - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 37
been taken to prevent loss of data. Determining whether a component is hot-pluggable Before removing any serviceable part, determine whether the part is hot-pluggable or non-hot-pluggable. • If the component is cooling within the device. 1510i Modular Smart Array maintenance and service guide 37 - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 38
maintenance window. 2. Ensure that a known good backup is available. 3. Power down all servers with access to the MSA, or if your operating system fully supports it, quiesce all I/O and dismount all LUNs. 4. On the MSA, press and hold down the Power on/Standby button on the front of the chassis - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 39
system, and log on as a user with administrative control. 7. Verify that each device in the network is operating properly. 1510i Modular Smart Array maintenance and service guide 39 - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 40
Removing or installing a 2-Port Ethernet iSCSI blank Before you begin CAUTION: • Before removing a component or blank from an operational device, make sure that you have the replacement part or blank available. Removing a component or blank impacts the airflow pattern and cooling ability of the - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 41
(2). Installing a hard drive blank Slide the blank into the enclosure chassis bay until it clicks into place. newpage pi 1510i Modular Smart Array maintenance and service guide 41 - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 42
Replacing a hard drive Before you begin CAUTION: • Before removing a component or blank from an operational device, make sure that you have the replacement part or blank available. Removing a component or blank impacts the airflow pattern and cooling ability of the device. Allow approximately 30 - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 43
hard drives are inside. (However, this LED also illuminates when other problems occur, such as when a fan fails, a redundant power supply The HP ProLiant Servers Troubleshooting Guide, available on the Management CD • MSA1510i installation and user guide Removing the hard drive NOTE service guide 43 - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 44
3. Press the ejector button (1) and pull the release lever to the full open position (2). IMPORTANT: Wait approximately 10 seconds for the internal disk to stop spinning before pulling the hard drive out of the enclosure. Handling a hard drive while the internal media is spinning can damage the - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 45
automatically with data from the other hard drives. While reconstruction is in progress, the Online LEDs flash. newpage pi 1510i Modular Smart Array maintenance and service guide 45 - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 46
battery pack • Installing the controller cache module • Installing the controller • Verifying the replacement Perform only the steps required for your service event. For example, re-seating an array controller includes Removing the controller and Installing the controller. Before you begin CAUTION - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 47
, schedule an maintenance window for the service. For instructions on shutting down the MSA, see (SMU) and disable the controller being removed. For instructions, see online help. (During this procedure, because one to perform the service. If your system is equipped with two controllers: - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 48
the failed controller. Using the same cache module completes disk writes trapped in the controller cache. 1. Remove the controller from the chassis as instructed in Removing the controller. 2. Locate the controller cover clips on the rear, lower left, and right sides of the module by holding the - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 49
cache module as instructed in Removing the controller cache module. 3. Push down on the battery retaining clip, located near the lower corner of the module. 4. Swing the battery pack away from the cache module to about a 30-degree angle. 1510i Modular Smart Array maintenance and service guide 49 - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 50
second battery pack on this cache module. Installing the controller cache battery pack 1. Remove the array controller as instructed in Removing the controller. 2. Remove the controller cache module as instructed in Removing the controller cache module. 3. Remove the controller cache battery pack as - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 51
second battery pack on the module. 8. Install the serviced cache module in the controller as instructed in Installing the controller cache module. NOTE: The cache Close the controller cover. 3. Insert the serviced controller into the chassis as instructed in Installing the controller. newpage pi - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 52
serviced array controller into the MSA chassis controller bay (1). 2. Push the controller in as far as it will go, making sure that the controller is seated, and then press the latch handle inward until it is flush against the front panel (2). 1 2 15493 3. If necessary, power on the MSA as instructed - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 53
, cautions, and preparation procedures as detailed in Warnings and precautions. 2. Disconnect the cable from the 2-Port Ethernet iSCSI module. 1510i Modular Smart Array maintenance and service guide 53 - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 54
3. Lift the port-colored 2-Port Ethernet iSCSI module latch (1) and pull the module out of the enclosure (2). Installing the 2-Port Ethernet iSCSI I/O module 1. Slide the replacement 2-Port Ethernet iSCSI module into the MSA chassis bay until the module clicks into place. 2. Reconnect the cables. - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 55
the fan module Slide the replacement fan module into the MSA chassis bay until the module clicks into place. 1510i Modular Smart Array maintenance and service guide 55 - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 56
15210 Verifying proper operation After replacing the fan module, verify that: • The fan starts operating immediately. • The fan Status LED is On. • No new error messages are displayed on the array controller LCD panel. newpage pi 56 Customer replaceable components - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 57
all cables. This ensures their reconnection in the correct configuration. 2. Disconnect all SCSI cables from the SCSI I/O module. 1510i Modular Smart Array maintenance and service guide 57 - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 58
3. Lift the port-colored SCSI I/O module latch (1) and pull the SCSI I/O module out of the chassis (2). Installing the SCSI I/O module 1. Slide the replacement SCSI I/O module into the MSA chassis bay until the module clicks into place. 2. Reconnect all SCSI cables. NOTE: Ensure that all of the SCSI - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 59
module latch (1) to the left, grasp the module handle and pull the defective power supply out of the chassis (2). 1510i Modular Smart Array maintenance and service guide 59 - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 60
Installing the power supply module 1. Slide the replacement power supply module into the MSA chassis bay until the module clicks into place. 2. Connect the AC power cord to the power supply. Verifying proper operation After replacing the power supply, verify that: • The power supply Status LED is - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 61
power cord. • Verify that the chassis Fault LED is blinking amber. • Verify that the chassis Status LED is off. 1510i Modular Smart Array maintenance and service guide 61 - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 62
Removing the chassis components Prepare for the replacement 1. Review all warnings, cautions, and preparation procedures as detailed in Warnings and precautions. 2. If the MSA is operational, stop all access to the MSA. 3. Press and hold the Power on/Standby button for five seconds to place the MSA - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 63
the controllers 1. Press the controller thumb latch to release the latch handle, and then rotate the latch handle out. 1510i Modular Smart Array maintenance and service guide 63 - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 64
firmware version, the serial number of the original chassis may automatically be transferred to the replacement chassis. For continued service and support from HP-authorized service personnel, the serial number of the original chassis must also be physically recorded on the label of the replacement - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 65
1. Slide the module into the chassis power supply slot until the latch clicks into place. 2. Install the other module. 1510i Modular Smart Array maintenance and service guide 65 - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 66
Install the SCSI I/O modules 1. Slide the module into the chassis SCSI I/O slot until the latch clicks into place. 2. Install all other SCSI I/O modules or blanks. Install the fan modules 1. Slide the module into the chassis fan slot until the latch clicks into place. 2. Install the other fan module - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 67
for them to complete their startup routines: • Uninterruptible Power Supplies • Network switches • External storage enclosures 4. Start up the MSA1510i. 1510i Modular Smart Array maintenance and service guide 67 - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 68
5. Read the controller LCD panel messages during the MSA startup routine. • If the following messages are displayed, the serial number of the original chassis was automatically transferred to the replacement chassis. SPARE CHASSIS DETECTED CHASSIS SERIAL NUMBER FLASHED UPDATED IMPORTANT: If these - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 69
both classes to bear a label indicating the interference potential of the device as well as additional operating instructions for the user. The rating label on the device shows which class (A or B) the equipment cause undesired operation. 1510i Modular Smart Array maintenance and service guide 69 - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 70
than those specified herein, or in the laser product's installation guide, may result in hazardous radiation exposure. To reduce the risk of • Do not try to open the module enclosure. There are no user-serviceable components inside. • Do not operate controls, make adjustments, or perform procedures - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 71
Immunity • EN61000-3-2 (IEC61000-3-2) - Power Line Harmonics • EN61000-3-3 (IEC61000-3-3) - Power Line Flicker • EN 60950 (IEC 60950) - Product Safety BSMI notice 1510i Modular Smart Array maintenance and service guide 71 - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 72
Japanese notice Korean notice (A&B) Class A equipment Class B equipment 72 Regulatory compliance and safety - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 73
m (12 ft). If you have questions about the type of power cord to use, contact an HP authorized service provider. NOTE: Route power cords so that they will not be walked on and cannot be pinched by items placed . Japanese Power Cord notice 1510i Modular Smart Array maintenance and service guide 73 - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 74
at standing workstations. Wear the straps on both feet when standing on conductive floors or dissipating floor mats. • Use conductive field service tools. • Use a portable field service kit with a folding static-dissipating work mat. If you do not have any of the suggested equipment for proper grounding - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 75
where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service, or the shop where you purchased the product. Estonian notice Seadmete jäätmete kõrvaldamine eramajapidamistes Euroopa Liidus 1510i Modular Smart Array maintenance - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 76
d'informations sur les centres de collecte et de recyclage des appareils mis au rebut, veuillez contacter les autorités locales de votre région, les services de collecte des ordures ménagères ou le magasin dans lequel vous avez acheté ce produit. German notice Entsorgung von Altgeräten aus privaten - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 77
savas dzīves vietas pašvaldībā, sadzīves atkritumu savākšanas dienestā vai veikalā, kurā izstrādājums tika nopirkts. 1510i Modular Smart Array maintenance and service guide 77 - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 78
Lithuanian notice Vartotojų iš privačių namų ūkių įrangos atliekų šalinimas Europos Sąjungoje Šis simbolis ant gaminio arba jo pakuotės rodo, kad šio gaminio šalinti kartu su kitomis namų ūkio atliekomis negalima. Šalintinas įrangos atliekas privalote pristatyti į specialią surinkimo vietą elektros - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 79
för hushållsavfall eller affären där du köpte produkten för att få mer information om var du kan lämna ditt avfall för återvinning. 1510i Modular Smart Array maintenance and service guide 79 - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 80
80 Regulatory compliance and safety - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 81
diagnostic tools, 29 document conventions, 8 prerequisites, 7 related documentation, 7 documentation HP website, 7 providing feedback, 10 E electrostatic discharge See ESD, 33 1510i Modular Smart Array maintenance and service guide 81 - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 82
, 45 hardware replacement overview, 31 hazardous conditions symbols on equipment, 34 help obtaining, 9 hot-pluggable parts, MSA1510i, 37 HP technical support, 9 HP Systems Insight Manager monitoring LUN parameters, 30 MSA controller parameters, 30 HP Systems Insight Manager, overview, 29 HP-SIM - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 83
part numbers, 11 powering off MSA1510i, 20 preparation procedures, 37 prerequisites, 7 Q qualified service personnel, warning, 31 R rack stability, warning, 9, 35 regulatory compliance, 69 related documentation , 64 proper operation, 68 1510i Modular Smart Array maintenance and service guide 83 - HP StorageWorks 1510i | HP StorageWorks 1510i Modular Smart Array maintenance an - Page 84
equipment, 34 T technical support HP, 9 service locator website, 9 thermal failure, caution, 41 tools required for servicing, 33 type recommended, replacing hard drive, 42 weight, 35 warnings, precautions, 33 warranty service HP limited warranty, 32 parts-only, 32 Waste Electrical and Electronic
HP StorageWorks
1510i Modular Smart Array maintenance and
service guide
Part number: 383072–002
Second edition: May 2008