installation guide hp StorageWorks SAN switch 2/16 version 3.1.x Product Version: 3.1.x Third Edition (June 2003) Part Number: AA-RR84C-TE This installation guide provides basic procedures for setting up, configuring, and managing the SAN Switch 2/16 and SAN Switch 2/16 power pak models. - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 2
® is a registered trademark of The Open Group. BROCADE, the Brocade B weave logo, Brocade: the Intelligent Platform for Networking Storage, SilkWorm, and an additional warranty. Printed in the U.S.A. SAN Switch 2/16 Version 3.1.x Installation Guide Third Edition (June 2003) Part Number: AA-RR84C- - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 3
15 HP Authorized Reseller 16 1 Overview 17 SAN Switch 2/16 Features 18 Firmware 18 Hardware 19 SFP Media Side 20 Optical Ports 20 ISL Trunking 21 SFPs 21 Power Supply Side 21 Field-Replaceable Units 21 Optional Hardware Kits 22 SAN Switch 2/16 Version 3.1.x Installation Guide 3 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 4
Series or EIA Rack 38 Securing the Rack Mount Brackets 39 Installing the Switch in the Optional HP System/e Rack 40 Items Required for the HP System/e Rack 40 Installing the Switch Using the HP StorageWorks SAN Switch Universal Rack Mount Kit 46 Connecting AC Power 56 Power-On Self Test 57 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 5
86 Restoring the System Configuration Settings 87 Upgrading or Restoring the Switch Firmware 88 Downloading Firmware from the HP Website 89 A Regulatory Compliance Notices 91 VCCI EMC Statement (Japan 92 Harmonics Conformance (Japan 93 SAN Switch 2/16 Version 3.1.x Installation Guide 5 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 6
rack 50 17 Assembling the outer rails (HP 9000 Series or comparable EIA rack 51 18 Assembling the outer rails (HP System/e rack 52 19 Assembling the inner rails 53 20 Installing the switch into a rack (HP 9000 Series or comparable EIA rack 54 6 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 7
5 Rear Panel LED Patterns During Normal Operation 76 6 Physical Specifications 100 7 Power Supply Specifications 101 8 Environmental Requirements 102 9 Cabling Pinouts if Pin 7 is Used 103 SAN Switch 2/16 Version 3.1.x Installation Guide 7 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 8
Contents 8 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 9
this guide This installation guAidbe porouvitdetshinisforGmautioindtoehelp you set up and configure the HP StorageWorks SAN Switch 2/16. About this Guide About this Guide topics include: ■ Overview, page 10 ■ Conventions, page 11 ■ Rack Stability, page 14 ■ Getting Help, page 15 SAN Switch 2/16 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 10
, please visit the following HP StorageWorks website: http://www.hp.com/country/us/eng/prodserv/storage.html For information about Fibre Channel standards, visit the Fibre Channel Association web site, located at: http://www.fibrechannel.org 10 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 11
www.hp.com Text Symbols The following symbols may be found in the text of this guide. They have the following meanings. WARNING: Text set off in this manner indicates that failure to follow directions in the warning could result in bodily harm or death. SAN Switch 2/16 Version 3.1.x Installation - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 12
indicates the presence of electrical shock hazards. Enclosed area contains no operator serviceable parts. WARNING: To reduce the risk of personal injury from electrical shock hazards, do not component, allow the surface to cool before touching. 12 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 13
Guide Power supplies or systems marked with these symbols indicate the presence of multiple sources of power. WARNING: To reduce the risk of personal injury from electrical and safety requirements and guidelines for manually handling material. SAN Switch 2/16 Version 3.1.x Installation Guide 13 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 14
, the stabilizing feet are attached to the rack. ■ In multiple rack installations, the racks are coupled. ■ Only one rack component is extended at any time. A rack may become unstable if more than one rack component is extended for any reason. 14 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 15
, specific questions HP Storage Website The HP website has the latest information on this product. Access storage at: http://thenew.hp.com/country/us/eng/prodserv/storage.html. From this website, select the appropriate product or solution. SAN Switch 2/16 Version 3.1.x Installation Guide 15 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 16
this Guide HP Authorized Reseller For the name of your nearest HP authorized reseller: ■ In the United States, call 1-800-345-1518. ■ In Canada, call 1-800-263-5868. ■ Elsewhere, see the HP website for locations and telephone numbers: http://www.hp.com 16 SAN Switch 2/16 Version 3.1.x Installation - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 17
enabled on your specific switch. Note: This guide refers to both models as the SAN Switch 2/16, unless otherwise noted. This chapter provides the following information: ■ SAN Switch 2/16 Features, page 18 ■ Firmware, page 18 ■ Hardware, page 19 SAN Switch 2/16 Version 3.1.x Installation Guide 17 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 18
fault isolation, automatically disables failing ports and restarts when the problem is resolved. ■ Industry standard Management Information Base (MIB) support. ■ Automatic self-discovery, discovers and registers host server and storage devices. 18 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 19
Port Readiness LED on the back panel ■ Universal input power supplies with AC switches and built-in fans. (The power supplies plug into internal blind-mate connectors when installed in the chassis.) ■ Two fan trays, each containing two fans NVRAM. SAN Switch 2/16 Version 3.1.x Installation Guide 19 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 20
port 2 Ethernet port 3 Optical ports (16) Figure 1: SFP media side 4 Port speed LEDs (16) 5 Port status LEDs (16) 6 Power switch LED Optical Ports All switch ports support full fabric capability. Full fabric allows the Fibre Channel SAN Switch 2/16 to link or cascade to other HP StorageWorks - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 21
switch must be turned off during replacement of the motherboard. To simplify replacement, the switch has a minimum of internal cables and no jumpers or hardware settings. Replacement instructions are provided with all replacement units ordered. SAN Switch 2/16 Version 3.1.x Installation Guide 21 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 22
Hardware Kits HP provides the following optional hardware kits in support of the SAN Switch 2/16, see Table 2. Table 2: SAN Switch 2/16 Orderable Hardware 221691-B27** C7534A* C7534A* * premerger HP part number ** premerger Compaq part number 22 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 23
page 27 ■ Installing the SAN Switch as a Stand-alone Unit, page 30 ■ Installing the SAN Switch 2/16 in an HP 9000 Series or Comparable EIA Rack, page 31 ■ Installing the Switch in the Optional HP System/e Rack, page 40 ■ Installing the Switch Using the HP StorageWorks SAN Switch Universal Rack Mount - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 24
Unpack the shipping cartons. Note: The Rack Mount Kit shown in Figure 3 and Table 3 may not represent the kit that shipped with your switch. HP reserves the right to substitute Rack Mount Kits, providing applicable instructions with each switch. 24 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 25
Installing the SAN Switch 2/16 2 3 1 5 4 6 Figure 3: Carton contents SHR-2489A SAN Switch 2/16 Version 3.1.x Installation Guide 25 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 26
Installing the SAN Switch 2/16 Table 3: Shipping Carton Contents Item Number 1 2 3 4 5 6 Description One HP StorageWorks SAN Switch 2/16 product accessory bag containing CD, license if installing so that port side slides from the rear • Right and left front mount brackets (2); use if installing so - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 27
As a fixed component using the optional HP StorageWorks SAN Switch Universal Rack Mount Kit. For instructions, see Installing the Switch Using the HP StorageWorks SAN Switch Universal Rack Mount Kit on page page 46. Note: Depending on time of purchase, the SAN Switch 2/16 ships with one of the rack - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 28
■ Power capability of 75 watts, maximum The switch has a universal power supply capable of functioning worldwide without voltage jumpers or switches. The power supply is auto ranging in terms of accommodating input voltages and line frequencies. 28 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 29
Installing the SAN Switch 2/16 Electrostatic Discharge Precautions To prevent electrostatic damage, observe the following precautions: ■ Avoid ■ Always make sure you are properly grounded when touching a static-sensitive component or assembly. SAN Switch 2/16 Version 3.1.x Installation Guide 29 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 30
steps 3 through 5 for the remaining power supply. Note: Do not connect the switch to the network until the IP address is correctly set. For instructions on how to set the IP address, see "Configuring Network Addressing" later in this chapter. 30 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 31
the SAN Switch 2/16 Installing the SAN Switch 2/16 in an HP 9000 Series or Comparable EIA Rack Read the following sections to install the switch in a rack using the Rack Mount Kit supplied with the switch. Obtain the following tools: ■ A #2 Phillips screwdriver ■ Torque screwdriver Installing the - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 32
. 1. Position the inner slide rails with the flat side against the switch, oriented in one of the following two ways: Note: HP recommends installing the SAN Switch 2/16 so that the port side of the switch slides out the rear of the HP 9000 Series Rack (as described in step 1a below). In this way - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 33
the port side of the switch slides out the back of the HP 9000 Series rack. (For example, the switch should face the aisle where exhaust air is released. Air intake and exhaust for all components in the rack should flow in the same direction.) SAN Switch 2/16 Version 3.1.x Installation Guide 33 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 34
switch, see Figure 5. Figure 5: Attaching the rear rack mount brackets SHR-2490A 3. Tighten the screws and torque to 15-inch pounds. 4. Repeat steps 1 through 3 to install the left mount bracket on the left side of the switch, see Figure 5. 34 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 35
rails in the HP 9000 Series Rack. Obtain the following items, located in the Rack Mount Kit: ■ Four 3-hole bar nuts ■ Eight Phillips head 8-32 x 3/8-inch screws ■ Eight square alignment washers ■ # 2 Phillips screwdriver with torque capability SAN Switch 2/16 Version 3.1.x Installation Guide 35 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 36
rail's length to fit the length of the HP 9000 Series Rack. 5. Position one of the outer slide rails in the rack, as described below: a. To allow the switch's port end to slide out the back of the at the end of the outer slide rail, see Figure 6. 36 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 37
required. Delete this set of instructions 1 5 1 Phillips head 10-32 x 3/8-inch screw 2 3-hole bar nut 3 Outer slide rail SHR-2478A 4 L-Brackets 5 Power cord clip (1 of 6) Figure 6: Attaching the outer slide rails to the HP 9000 Series rack SAN Switch 2/16 Version 3.1.x Installation Guide 37 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 38
outer slide rails all the way toward the front or back of the rack. 2. Carefully lift the switch into the rear of the rack, inserting the inner slide rails (attached to the switch) into the outer slide rails (attached to the rack), see Figure 7. 38 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 39
rack mount bracket to the rack rails. 3. Tighten the screws, and torque to 25-inch pounds. 4. See the "Connecting AC Power" on page 56 for instructions on applying power to the switch. SAN Switch 2/16 Version 3.1.x Installation Guide 39 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 40
Installing the SAN Switch 2/16 Installing the Switch in the Optional HP System/e Rack This section provides instructions for installing the switch in the HP System/e rack. Items Required for the HP System/e Rack The HP System/e Rack Kit consists of the following items: ■ HP System/e Rack Rail Kit, - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 41
hardware is available. 2. Choose a mounting location in the rack for the switch. 3. Install each of the two mounting brackets with one M5 Torx head screw with captive lock washers as shown in Figure 8. Figure 8: Installing the mounting brackets SAN Switch 2/16 Version 3.1.x Installation Guide 41 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 42
assembly, two rubber washers have been included to help keep the rear slotted portion of the outer rail flush against the rear rail-tray brackets. Install them as shown in Figure 10. 42 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 43
rack. 6. Install one M5 Torx screw in the upper hole location of the right rail. Then, install one M5 Torx screw in the lower location of the left rail. See Figure 11. Note: Do not install the upper left and the lower right screws until later. SAN Switch 2/16 Version 3.1.x Installation Guide 43 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 44
Figure 11: Assembling the outer rails (HP rack) 7. Assemble the two inner rails (one on each side) to the switch using (6) #8-32 x 5/16 Phillips pan-head screws, and #8 flat washer as shown in Figure 12. Figure 12: Assembling the inner rails 44 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 45
the two remaining M5 Torx screws to complete the installation. See Figure 13. Figure 13: Installing switch into the HP rack SHR-2583 10. See the next section, "Connecting AC Power" on page 56, for instructions on applying power to the switch. SAN Switch 2/16 Version 3.1.x Installation Guide 45 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 46
the SAN Switch 2/16 Installing the Switch Using the HP StorageWorks SAN Switch Universal Rack Mount Kit This section provides instructions for installing the SAN Switch 2/16 in an HP rack using the Universal Rack Mount Kit, part number 331148-B21. The following items are required: ■ SAN Switch 2/16 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 47
prevents switch overheating, which may cause it to fail. To install the switch in a rack: 1. Check contents of the shipping carton to verify all the required parts and hardware are available. 2. Choose a mounting location in the rack for the switch. SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 48
brackets with (2) #10-32 x 1/2-inch Phillips pan-head screws with captive star lock washers and (2) #10 adapter washers as shown in Figure 14. Figure 14: Installing the rear mounting brackets (HP 9000 Series or comparable EIA rack) 48 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 49
rack, install each of the two rear mounting brackets with (2) #10-32 x 1/2-inch Phillips pan-head screws and (2) #10 alignment washers as shown in Figure 15. Figure 15: Installing the rear mounting brackets (HP System/e rack-left rear upright) SAN Switch 2/16 Version 3.1.x Installation Guide 49 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 50
using (2) 1/4-20 hex nuts with captive star lock washers attached loosely as shown in Figure 16. Don't tighten them. The nuts will be tightened later in step 8. Figure 16: Installing the outer rails (HP 9000 Series or comparable EIA rack) 50 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 51
and two #10 adapter washers in the upper and lower hole locations of the left rail. See Figure 17. Figure 17: Assembling the outer rails (HP 9000 Series or comparable EIA rack) SAN Switch 2/16 Version 3.1.x Installation Guide 51 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 52
install two #10-32 x 1/2-inch Phillips pan-head screws with captive star lock washers and two #10 alignment washers in the upper and lower hole locations of the left rail. See Figure 18. Figure 18: Assembling the outer rails (HP System/e rack) 52 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 53
Each switch requires a different number of these screws. For example, Figure 19 shows the an inner rail being attached to the SAN Switch 2/16 with five screws. Attaching both inner rails requires ten screws. Figure 19: Assembling the inner rails SAN Switch 2/16 Version 3.1.x Installation Guide 53 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 54
EIA rack. 7. Install (2) #10-32 x 1/2-inch Phillips pan-head screws with captive star lock washers with one on each side. See Figure 20 and Figure 21. Figure 20: Installing the switch into a rack (HP 9000 Series or comparable EIA rack) 54 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 55
a rack (HP System/e rack) 8. Tighten the nuts installed in step a of step 4 on page 50. Note: To uninstall a switch, remove the middle #10-32 x 1/2-inch Phillips pan head screw with captive star lock washer from either side of the rack uprights. SAN Switch 2/16 Version 3.1.x Installation Guide 55 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 56
rails. However, the tabs on the clips can be on either side of the rail, provided all the tabs are on the same side. 56 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 57
state, (and this is not due to the switch being set to beacon), see "Interpreting LED Activity" on page 72 in Chapter 3. Note: For more information about beaconing, refer to the HP StorageWorks Fabric OS Version 3.1x/4.1x Procedures User Guide. SAN Switch 2/16 Version 3.1.x Installation Guide 57 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 58
Installing the SAN Switch 2/16 Checking POST Results Check the success/fail results of the diagnostic tests run during POST via LED activity, the error log, or Command Line Interface (CLI) using the errShow command. For more information about error messages, refer to the HP StorageWorks Fabric OS - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 59
that the switch power is on and POST is completed. See the "Power-On Self Test" section, earlier in this chapter. 5. Power on the workstation and establish a connection to the switch using a terminal emulator application (such as HyperTerminal). SAN Switch 2/16 Version 3.1.x Installation Guide 59 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 60
Installing the SAN Switch 2/16 Note: These steps show instructions specific to HyperTerminal. If using a different application, consult the specific application's documentation. 6. Using HyperTerminal (or similar application), configure the Port . 60 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 61
only for use during the initial setting of the IP address and for service purposes. Using the Serial port during normal switch operation or for regular maintenance is not recommended. 8. Record the IP address on the label affixed to the switch. SAN Switch 2/16 Version 3.1.x Installation Guide 61 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 62
Installing the SAN Switch 2/16 Connecting the Switch to the LAN Use the following steps to connect the switch to the Ethernet Local Area Network (LAN) segment. 1. Remove the shipping plug from the Ethernet port. 2. Connect one end of an Ethernet cable to the Ethernet port, see Figure 24. Figure 24: - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 63
used in Fibre Channel. The Core PID format is analogous to specifying the physical switch and port a device is attached to in data networks. It is not analogous to an IP address. 1 or 0, depending on the number displayed in the brackets. SAN Switch 2/16 Version 3.1.x Installation Guide 63 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 64
Fibre Channel cables. 11. If necessary, type cfgEnable to re-establish zoning. Note: Once the switch PID format is set, it is stored in the flash memory of the switch, and it is NOT necessary to set it again during subsequent firmware upgrades. 64 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 65
previous switch, if still available). Domain: (1..239) [1] 3 5. Complete the remaining prompts (or press CTRL+D to accept the remaining settings without completing all the prompts). 6. Re-enable the switch by entering the following: switchEnable SAN Switch 2/16 Version 3.1.x Installation Guide 65 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 66
the SFP into the port until it is firmly seated and the latching mechanism clicks. Note: The SFP is keyed so that it can only be inserted into the port with the correct orientation. If the SFP does not slide in easily, check the orientation. 66 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 67
to verify that the switch is running properly. 1. Access your browser. 2. At the URL address window, type http://your switch IP address. 3. If connected properly, the name of your switch appears (in green) at the prompt, indicating Healthy/OK. SAN Switch 2/16 Version 3.1.x Installation Guide 67 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 68
in the package contents, between a host computer and the Serial port of the switch. See the "Setting Network Addresses via a Serial Connection" earlier in this chapter, to make a Serial connection through a workstation and to set the IP address. 68 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 69
set the speed level for all ports in a switch. Use the portCfgSpeed to set the speed level for a single port. Depending on your environment you may need to force a port to use a specific speed level. Auto negotiation may not be supported by the SAN Switch 2/16 Version 3.1.x Installation Guide 69 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 70
Installing the SAN Switch 2/16 device. Check the configuration information for your network components for specific requirements. See the HP StorageWorks Fabric OS Version 3.1.x/4.1.x Procedures User Guide for a detailed command description. Cascading Switches The Domain ID number uniquely - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 71
Managing the SAN Switch 2/16 3 This chapter covers the following topics: ■ Interpreting LED Activity, page 72 ■ Management Overview, page 78 ■ Running Basic Switch Operations Using Telnet, page 79 ■ Diagnostic Tests, page 84 SAN Switch 2/16 Version 3.1.x Installation Guide 71 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 72
LEDs: ■ One Switch Power LED on the front panel ■ One Port Status LED above and to the left of each of the 16 ports ■ One Port Speed LED above and to the left of each of the 16 port Table 4 describes front panel LEDs and their functionality. 72 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 73
command). Recommended Action Check media and cable. No action required. Verify correct device is conncted to port. No action required. No action required. No action required. No action required. Reset the switch from a management station. SAN Switch 2/16 Version 3.1.x Installation Guide 73 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 74
. The port is transmitting/receiving at 1 Gbps. The port is transmitting/receiving at 2 Gbps. Recommended Action Reset the switch from a management station. Reset the port from a management station. No action required. No action required. 74 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 75
boot has had time to complete. If there is still no light, contact the switch supplier. No action required. Errors may be listed in the error log. Refer to the HP StorageWorks Fabric OS Version 3.1.x/4.1.x Procedures Guide for more information. SAN Switch 2/16 Version 3.1.x Installation Guide 75 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 76
of the switch. Table 5: Rear Panel LED Patterns During Normal Operation LED Power Supply LED LED Location On each power supply Port Status LED switch is on and boot had time to complete. If there is still no light, contact the switch supplier. 76 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 77
the Port Status LEDs for fault indicators. Slow-flashing yellow Diagnostic failure on one or more ports. Errors may be listed in the error log. Refer to the HP StorageWorks Fabric OS Version 3.1.x/4.1.x Procedures Guide for more information. SAN Switch 2/16 Version 3.1.x Installation Guide 77 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 78
User Guide. Optional Management Features Refer to the HP StorageWorks SAN Switch 2/16 Version 3.1.x Release Notes for a complete list of management features enabled on the switch. Displaying the Optional Feature Licenses Use these steps to display optional features installed on your switch. 1. Log - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 79
sections to run common switch operations. Logging into the Switch Use these steps to log into the switch. 1. Open a telnet connection to the switch. The login prompt displays if the telnet connection successfully found the switch in the network. SAN Switch 2/16 Version 3.1.x Installation Guide 79 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 80
Managing the SAN Switch 2/16 Note: The switch must be connected to your IP network through the RS-232 port to enable connection through telnet. 2. At the login prompt, enter the . The new password must be from 8 to 40 characters in length. 80 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 81
for the Ethernet port on the switch. Press the Enter switch firmware. 8. You are then prompted either to make the IP address changes active now or at the next reboot. Enter y at the prompt to have the IP address changes take effect immediately. SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 82
all the connected devices in the fabric. Checking the Firmware Version Use these steps to display the firmware version. 1. Log in to the switch as the admin user. 2. At the command line, are 00-59. - YY is the year, valid values are 00-99. 82 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 83
Switch Configuration Settings Use these steps to display the system configuration settings. 1. Log into the switch as the admin user. 2. At the command line, enter the following command: configShow The system configuration settings are displayed. SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 84
diagnostic tests and how to run them, refer to the HP StorageWorks Fabric OS Procedures Version 3.1.x/4.1.x User Guide. Note: The transmit and receive speed of the links may be temporarily locked to a specific speed during diagnostic testing. 84 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 85
the Configuration and Upgrading Firmware 4 This chapter covers the following topics: ■ Backing Up System Configuration Settings, page 86 ■ Upgrading or Restoring the Switch Firmware, page 88 ■ Downloading Firmware from the HP Website, page 89 SAN Switch 2/16 Version 3.1.x Installation Guide 85 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 86
prompt you for each parameter, as follows: Example: switch:admin> configupload Server Name or IP Address [host]: 123.45.678.901 User Name [user]: kelev File Name [config.txt]: switch1 Protocol (RSHD or FTP) [rshd]: ftp Password: upload complete 86 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 87
file, and password is the password for the user ID specified. Note: The password operand is only required if you are using FTP. 5. Reboot the switch by entering the following command: fastBoot SAN Switch 2/16 Version 3.1.x Installation Guide 87 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 88
is the path location and filename of the new firmware file, and password is the password for the user ID specified. Note: The password operand is only required if you are using FTP. 4. Reboot the switch by entering the following command: fastBoot 88 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 89
and Upgrading Firmware Downloading Firmware from the HP Website To download the firmware from the HP website, go to http://www.hp.com. The website contains the required loaders and instructions for downloading the firmware to a switch. SAN Switch 2/16 Version 3.1.x Installation Guide 89 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 90
Backing Up the Configuration and Upgrading Firmware 90 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 91
uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of could void the user's authority to operate the equipment. SAN Switch 2/16 Version 3.1.x Installation Guide 91 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 92
may be required to take adequate measures. Spécification ATI Classe A (France) DECLARATION D'INSTALLATION ET DE MISE EN EXPLOITATION d'un matériel de traitement de l'information (ATI), class ISO 7779:1999 (Typprüfung) VCCI EMC Statement (Japan) 92 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 93
Harmonics Conformance (Japan) BSMI EMC Statement (Taiwan) Regulatory Compliance Notices RRL EMC Statement (Korea) SAN Switch 2/16 Version 3.1.x Installation Guide 93 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 94
conforming to the requirements contained in Department Of Health and Human Services (DHHS) regulation 21 CFR, Subchapter J. The certification is indicated CFR(J) B. Product Information Each communications port consists of a transmitter and receiver SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 95
replacement or proper disposal, contact your HP authorized reseller or your authorized service provider. WARNING: Your switch contains an internal lithium manganese dioxide system or return them to HP, your authorized HP partners, or their agents. SAN Switch 2/16 Version 3.1.x Installation Guide 95 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 96
Regulatory Compliance Notices 96 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 97
to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other static-sensitive devices grounded when touching a static-sensitive component or assembly. SAN Switch 2/16 Version 3.1.x Installation Guide 97 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 98
do not have any of the suggested equipment for proper grounding, have an HP authorized reseller install the part. Note: For more information on static electricity, or for assistance with product installation, contact your HP authorized reseller. 98 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 99
Technical Specifications This appendix covers the following topics: ■ Dimensions, page 100 ■ Power Supply Specifications, page 101 ■ Environmental Requirements, page 102 ■ Memory Specifications, page 103 C SAN Switch 2/16 Version 3.1.x Installation Guide 99 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 100
2/16 dimensions. Table 6: Physical Specifications Height Dimension Depth Width Weight (with both power supplies) Value 1.72 +/- 0.01 inches (4.37 +/- 0.03 cm) 24.5 +/- 0.03 inches (62.2 +/- 0.1cm) 17 inches (43.2 cm) 28.0 lbs (12.7 kg) 100 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 101
fan for cooling, pushing the air towards the front of the switch. Table 7: Power Supply Specifications Specification Outlet Total power available from each power supply Max. switch 300 usec - hot/cold start Fused in both hot & neutral lines . SAN Switch 2/16 Version 3.1.x Installation Guide 101 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 102
environmental ranges that are acceptable when the switch is operating, and the acceptable ranges when the switch is not operating. .Table 8: Environmental Requirements sq.wave 5G, 0-3 kHz at 1.0 octave/minute 10G, 0-5kHz at 1.0 octave/minute 102 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 103
in Table 9. .Table 9: Cabling Pinouts if Pin 7 is Used PIN 1 2 3 4 5 6 7 8 9 Signal Description TxData RxData Transmit Data Receive Data GND Logic Ground CTS Clear to Send SAN Switch 2/16 Version 3.1.x Installation Guide 103 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 104
Technical Specifications 104 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 105
port. Alias Server A fabric software facility that supports multicast group management. API Application Programming Interface; defined protocol that allows applications to interface with a set of services before beginning loop initialization. SAN Switch 2/16 Version 3.1.x Installation Guide 105 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 106
between two ports. Consists of two virtual circuits capable of transmitting in opposite directions. See also Link. Command Line Interface that depends entirely on the use of commands, such as through telnet or SNMP, and does not involve a GUI. 106 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 107
; the number of receive buffers allocated by a recipient port to an originating port. Used by Class 1 and 2 services to manage the exchange of frames across the fabric between source and destination. See also End-to-end Flow Control, BB_Credit. SAN Switch 2/16 Version 3.1.x Installation Guide 107 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 108
F_Port Fabric Port; a port that is able to transmit under fabric protocol and interface over links. Can be used to connect an N_Port to a switch. Fabric A protocol service that supports communication between Fibre Channel service providers. 108 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 109
Channel. Set the gateway address on one switch to the Fibre Channel IP address of another switch to enable the other switch to forward IP traffic to the Ethernet port on the second switch. Gbps Gigabits per second (1,062,500,000 bits/second). SAN Switch 2/16 Version 3.1.x Installation Guide 109 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 110
Channel link from the E_Port of one switch to the E_Port of another. See also Services A protocol for link-related actions. Link As applies to Fibre Channel, a physical connection between two ports, consisting of both transmit and receive fibers. 110 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 111
that wins arbitration in an arbitrated loop and sends an OPN ordered set to the destination port, then enters the Open state. Open Recipient The L_Port that receives the OPN ordered set from the open originator, and then enters the Open state. SAN Switch 2/16 Version 3.1.x Installation Guide 111 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 112
port. Communicated during login and port discovery. POST Power On Self-Test; a series of tests run by a switch after it is turned on. Private Device A device that supports arbitrated and can communicate with either private or public NL_Ports. 112 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 113
support 20-bit addresses (or has 20-bit phantom addresses created for it by the switch The assignment of frames to specific switch ports, according to frame destination. RR_TOV Resource Service Rate The rate at which an entity can service requests. SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 114
multiple ports without reentering the arbitration cycle for each circuit. This state can only be accessed by an L_Port in the Open state. Translative Mode A mode in which private devices can communicate with public devices across the fabric. 114 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 115
entity in a fabric has a separate WWN. Xmitted Close State The state in which an L_Port cannot send messages, but can retransmit messages within the loop. A port in the XMITTED CLOSE state cannot attempt to arbitrate. SAN Switch 2/16 Version 3.1.x Installation Guide 115 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 116
partitioning of the fabric into logical groupings of devices. Devices in a zone can only access and be accessed by devices in the same zone. 116 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 117
the installed feature licenses 78 displaying the system configuration settings 83 distributed name server 20 document conventions 11 prerequisites 10 related documentation 10 domain address 69 domain ID 70 configuring 65 default 65 domain IDs 65 SAN Switch 2/16 Version 3.1.x Installation Guide 117 - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 118
addressing 58 NVRAM 19 O optical ports LEDs 72 outer slide rails 35 P physical dimensions of switch 100 port ethernet port 19 LED for port speed 72 LED for port status 72 serial port 19 speed 20 positioning the switch inside the rack 39 POST 57, 58 SAN Switch 2/16 Version 3.1.x Installation Guide - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 119
feature 18 selecting an operating location 27 SAN Switch 2/16 Version 3.1.x Installation Guide Index separating inner rail from outer rails 31 serial port cabling pinouts 103 setting network addressing via serial port 59 setting the IP address 61 setting the switch date and time 82 SFPs 66 SNMP - HP StorageWorks 16-EL | SAN switch 2/16 v3.1.x installation guide - Page 120
Index W warning rack stability 14 symbols on equipment 12 web tools 78 websites HP storage 15 weight, switch 100 Z zoning summary 18 120 SAN Switch 2/16 Version 3.1.x Installation Guide
installation
guide
hp
StorageWorks
SAN switch 2/16
version 3.1.x
Product Version:
3.1.x
Third Edition (June 2003)
Part Number:
AA-RR84C-TE
This installation guide provides basic procedures for setting up, configuring, and managing
the SAN Switch 2/16 and SAN Switch 2/16 power pak models.