- HP StorageWorks 1606 | HP StorageWorks SAN Switch rack mount kit installation in - Page 1
switch models: • SAN Switch 2/8V • SAN Switch 2/8 • SAN Switch 2/8-EL • SAN Switch 2/16V • SAN Switch 2/16 • SAN Switch 2/16N • SAN Switch 2/32 • SAN Switch 4/32 • SAN Switch 4/32B • 4/8 SAN Switch • 4/16 SAN Switch • 4/64 SAN Switch • 8/8 SAN Switch • 8/24 SAN Switch • 8/40 SAN Switch • 8/80 SAN - HP StorageWorks 1606 | HP StorageWorks SAN Switch rack mount kit installation in - Page 2
switch models only: • SAN Switch 2/8V • SAN Switch 2/8 • SAN Switch 2/16V • 4/8 SAN Switch • 4/16 SAN Switch • 4/32B SAN Switch • 8/8 SAN Switch • 8/24 SAN Switch See "Installing the plenum (if required)" on page 6 for instructions , 4/64 SAN Switch, 8/80 SAN Switch, and Encryption SAN Switch, plan - HP StorageWorks 1606 | HP StorageWorks SAN Switch rack mount kit installation in - Page 3
Item Description Eight #10 adapter washers Two 1/4-20 hex nuts with captive star lock washers Two 1/4-inch flat washers 3. Attach the rear mounting brackets to the rear rack uprights. • For an HP 10000 Series Rack, assemble each of the brackets using two #10-32 x 1/2-inch Phillips panhead - HP StorageWorks 1606 | HP StorageWorks SAN Switch rack mount kit installation in - Page 4
rails Device model #8-32 x 5/16-inch screws #8-32 x 3/16inch screws SAN Switch 2/16 SAN Switch 2/8V SAN Switch 2/16V Ten (five per rail) N/A SAN Switch 2/32 N/A Twelve (six per rail) 4/8 SAN Switch 4/16 SAN Switch SAN Switch 4/32 Ten (five per rail) N/A 4/32B SAN Switch Six (three per - HP StorageWorks 1606 | HP StorageWorks SAN Switch rack mount kit installation in - Page 5
• To attach the inner rails to the SAN Switch 2/32, use the screw holes marked 32. • To attach the inner rails to the 4/8, 4/16, 8/8, or 8/24 SAN Switch, use the five screw holes marked 8. The plenum requires one screw hole marked 8 and one screw hole marked 16, as shown in Figure 8 on page 6. • To - HP StorageWorks 1606 | HP StorageWorks SAN Switch rack mount kit installation in - Page 6
plenum included in the switch accessory kit: • SAN Switch 2/8V • SAN Switch 2/16 • SAN Switch 2/16V • 4/8 SAN Switch • 4/16 SAN Switch • 4/32B SAN Switch • 8/8 SAN Switch • 8/24 SAN Switch See "Installing the plenum (if required)" on page 6 for installation instructions. If you are not installing
HP StorageWorks
SAN Switch rack mount kit
installation instructions
© Copyright 2004-2009 Hewlett-Packard Development Company,
L.P.
Ninth edition: September 2009
The information in this document is subject to change without notice.
Printed in the US
www.hp.com
A7511-90905
About this document
This document describes how to use the SAN Switch Rack Mount Kit
(part number A7511A) to rack mount SAN switches and routers.
Supported devices
Use the SAN Switch Rack Mount Kit to install the following switch models:
•
SAN Switch 2/8V
•
SAN Switch 2/8
•
SAN Switch 2/8-EL
•
SAN Switch 2/16V
•
SAN Switch 2/16
•
SAN Switch 2/16N
•
SAN Switch 2/32
•
SAN Switch 4/32
•
SAN Switch 4/32B
•
4/8 SAN Switch
•
4/16 SAN Switch
•
4/64 SAN Switch
•
8/8 SAN Switch
•
8/24 SAN Switch
•
8/40 SAN Switch
•
8/80 SAN Switch
•
1606 Extension SAN Switch
•
FCoE Converged Network Switch
•
Encryption SAN Switch
•
Multi-protocol (MP) Router
•
400 Multi-protocol (MP) Router
Supported HP custom racks
Use the SAN Switch Rack Mount Kit with the following HP StorageWorks
custom racks only:
•
HP 9000 Series Rack
•
HP 10000 Series Rack
•
HP 10000 G2 Series Rack
•
HP System/e Rack
NOTE:
In this document, “HP 10000 Series Rack” refers to both the HP
10000 Series Rack and the HP 10000 G2 Series Rack.