Installation Guide hp StorageWorks SAN Director 2/128 Product Version: 4.2.x Second Edition (April 2004) Part Number: AA-RVUSB-TE This installation guide provides procedures for setting up, configuring, and managing the Enterprise class SAN Director 2/128 switch. - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 2
subject to change without notice. Microsoft®, Windows®, Windows NT®, Windows 2000® and Windows Millenium Edition® are U.S. registered trademarks of Microsoft Corporation. warranty. Printed in the U.S.A. SAN Director 2/128 Installation Guide Second Edition (April 2004) Part Number: AA-RVUSB-TE - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 3
16 Hardware Components 17 High Availability 20 Reliability 21 Serviceability 22 Optional Management Features 22 Interoperability 22 Security 22 Network Manageability 23 Management Summary 24 Managing the SAN Director 2/128 24 Supported Features 26 Optional Hardware Kits 27 SAN Director - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 4
Power Requirements 39 Installing the Switch as a Stand-alone Unit 39 Removing the Chassis Door 40 Installing the SAN Director 2/128 on a Flat Surface 41 Installing the SAN Director 2/128 Rack Mount Guidelines 43 Installing the SAN Director 2/128 in an HP or Comparable EIA Cabinet 44 Attaching - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 5
98 POST 98 Boot 99 Diagnostics 100 Troubleshooting the SAN Director 2/128 101 4 Installing SAN Director 2/128 FRUs 105 Replacing the Chassis Door 106 Replacing the Cable Management Tray 108 Replacing the Cable Guides (Pillars 110 Replacing a 16-Port Card and Filler Panel 111 Preliminary - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 6
Weight 163 System FRU Weights 164 Facility Requirements 165 Power Specifications 166 Environmental Requirements 167 Power Cords 168 Fibre Channel Port Specifications 172 CP Card EMC Statement (Japan 180 RRL EMC Statement (Korea 181 Laser Safety 182 6 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 7
CP card removal and replacement 123 26 Power supply removal and replacement 137 27 Blower assembly removal and replacement 140 28 WWN Bezel and card removal and replacement 148 29 Two modems attached for high availability 153 30 Remote modem setup 156 SAN Director 2/128 Installation Guide 7 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 8
Commands 97 14 Troubleshooting the SAN Director 2/128 101 15 Data Stored on the WWN Card 142 16 Messages That Might Indicate a WWN Card Failure 142 17 SAN Director 2/128 System Specification 162 18 System Size and Weight 163 19 FRU Weights 164 20 Power Specifications 166 21 Environmental - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 9
provides information to help you: ■ Review SAN DAirbecotoru2t/1t2h8 ihsardGwaureicdoemponents ■ Set up and configure the SAN Director 2/128 About this Guide ■ Operate and manage the SAN Director 2/128 ■ Install SAN Director 2/128 Field Replaceable Units (FRUs) ■ Set up and install modems "About - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 10
Director 2/128 power pack. The switch overview page displays. 7. Go to the "product information section," located on the far right side of the web page. 8. Click technical documents. 9. Follow the onscreen instructions to download the applicable documents. 10 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 11
Blue text: Figure 1 Bold Italics Monospace font Monospace, italic font Blue underlined sans serif font text (http://www.hp.com) Element Cross-reference links Menu items, buttons, and key, tab, follow directions could result in damage to equipment or data. SAN Director 2/128 Installation Guide 11 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 12
these symbols indicates the presence of electrical shock hazards. Enclosed area contains no operator serviceable parts. WARNING: To reduce the risk of personal injury from electrical shock hazards, hot component, allow the surface to cool before touching. 12 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 13
handle safely. WARNING: To reduce the risk of personal injury or damage to the equipment, observe local occupational health and safety requirements and guidelines for manually handling material. SAN Director 2/128 Installation Guide 13 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 14
or solution. HP Authorized Reseller For the name of your nearest HP authorized reseller: ■ In the United States, call 1-800-345-1518 ■ In Canada, call 1-800-263-5868 ■ Elsewhere, see the HP web site for locations and telephone numbers: http://www.hp.com. 14 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 15
Overview This chapter provides the following information: ■ Key Features, page 16 ■ Hardware Components, page 17 ■ High Availability, page 20 ■ Reliability, page 21 ■ Serviceability, page 22 ■ Management Summary, page 24 ■ Optional Hardware Kits, page 27 1 SAN Director 2/128 Installation Guide 15 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 16
deliver unprecedented reliability, availability, and serviceability (RAS). ■ Support for 1 and 2 Gb/sec autosensing Fibre Channel ports (trunking technology groups up to four ports together to create high-performance 8 Gb/sec ISL trunks between switches). 16 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 17
a wide range of flexibility in switch installation, fabric design, and maintenance. HP supports two SAN Director 2/128 switches in an HP 10,000 series, HP System/e or comparable EIA cabinet. The modular chassis consists of the following: ■ Up to eight hot-swappable 16-port cards, delivering up to - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 18
Connector Switch (for Power Supply 2 & 4) Power Supply Filler Panel Card Slot Filler Panel Power Supply #2 Power Supply #1 Cable Management Tray 2.001 Figure 1: SAN Director 2/128 (port side) Note: Card slots are numbered 1 through 10 (left to right). Slots 1-4 and 7-10 accommodate the 16-port - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 19
Power Supply LEDs 1 2 3 4 5 6 7 8 9 10 pwr4 pwr3 pwr2 pwr1 Blower Power LED Blower Fault LED Blower Handle Blower Assembly #3 Overview 2.006 Blower Assembly #1 scale: 3/16" = 1" Blower Assembly #2 Figure 2: SAN Director 2/128 (non-port side) SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 20
following features contribute to the SAN Director 2/128 high-availability design: ■ Redundant, hot-swappable components ■ Redundant power and cooling subsystems ■ flow control and message buffering, and supports a centralized active and standby state. 20 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 21
simplify troubleshooting. The standby control processor continuously runs diagnostics to ensure it is operational, should a failover be necessary. ■ I2C monitoring and control, used between Integrated Circuits (IC) to monitor how they are working. SAN Director 2/128 Installation Guide 21 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 22
The SAN Director 2/128 provides the following features to enhance and ensure serviceability: ■ Modular design with hot-swappable components ■ Redundant flash memory that stores two firmware images per control processor ■ Extensive diagnostics and status reporting, along with a serial port to support - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 23
switches and ports. In addition, all management interfaces, such as telnet, Web Tools, the Fabric Access Layer API, and Management Server, support SAN administrator. Note: Refer to the HP StorageWorks MIB 4.2.x Reference Guide for additional MIB information. SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 24
support, contact the switch provider. The SAN Director 2/128 includes the Fabric OS and is compatible with HP StorageWorks 1 Gb and 2 Gb SAN switches. Note: For information about upgrading the Fabric OS, refer to the HP StorageWorks Fabric OS 4.2.x Procedures User Guide. . 24 SAN Director 2/128 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 25
Out-of-band Support Ethernet or serial connection Ethernet Ethernet Ethernet Ethernet Note: To ensure efficiency and interoperability, HP recommends upgrading switches to the latest firmware version. Go to http://www.hp.com to obtain the latest firmware. SAN Director 2/128 Installation Guide 25 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 26
HP StorageWorks SAN Director 2/128 Version 4.2.x Release Notes to determine which features require purchasing a license key for activation. ■ Zoning ■ Secure Fabric OS ■ ISL Trunking ■ Fabric Watch ■ Performance Monitoring ■ Extended Fabric ■ Remote Switch 26 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 27
* 221692-B22** C7526A* 221692-B23** C7527A* 221692-B26** 221692-B27** C7529A* 221691-B21** C7530A* 221691-B21** 221691-B23** 221691-B26** 221691-B27** C7534A* C7534A* * premerger HP part number ** premerger Compaq part number SAN Director 2/128 Installation Guide 27 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 28
Overview 28 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 29
Installation Overview, page 38 ■ Powering on the SAN Director 2/128, page 57 ■ Establishing a Serial Connection, page 61 ■ Managing Cables, page 63 ■ Initial Configuration Parameters, page 67 ■ Configure IP Addresses for CP Cards, page 69 ■ Configure IP Address for the Switch, page 71 ■ Establish an - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 30
of 55 inches (140 cm), with a minimum capacity of 212 lbs (96 kg). HP StorageWorks SAN Director 2/128 Installation Guide, part number AA-RVUSA-TE (this guide) Power cables and serial cable (provided in SAN Director 2/128 accessory kit) Workstation computer with a serial port or terminal server port - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 31
Items Required Ethernet cabling (optional) for telnet access All other configuration parameters optional Refer to the HP StorageWorks Fabric OS 4.2.x Procedures User Guide for PID information SFP optical transceivers Fiber optic cables and cable guides SAN Director 2/128 Installation Guide 31 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 32
manual provided with the equipment rack to determine rack stability (available through the HP Web site at: http://www.hp before operation. WARNING: A fully populated HP StorageWorks SAN Director 2/128 weighs approximately 250 pounds (113 kg) power strip. 32 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 33
power cord to a separate power source. ■ Ensure the HP StorageWorks SAN Director 2/128 has access to a minimum airflow of 350 cubic feet per minute. ■ Ensure the air temperature measured at the blower inlet does not exceed 40 degrees Celsius during operation. SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 34
3: SAN Director 2/128 carton contents SHR-2506A Note: SFP transceivers can be ordered separately from your authorized HP representative. The SAN Director 2/128 supports SWL, LWL, and ELWL transceivers. See SAN Director 2/128 Orderable Hardware, page 27. 34 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 35
Director 2/128 Carton Contents Checklist Summary SAN Director 2/128 base configuration consists of two CP cards, two 16-port cards, one WWN card, two power supplies, three blower assemblies, one cable management tray, and sixteen cable management guides. One set of HP StorageWorks SAN Director 2/128 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 36
Installing and Configuring the SAN Director 2/128 Site Planning and Safety Guidelines WARNING: A fully populated SAN Director 2/128 (two power supplies) weighs approximately 250 lbs (113 kg) and requires a minimum of two people and a hydraulic or assisted lift to install it. Do not use the any of - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 37
chassis nameplate - Easily accessible to the SAN Director 2/128 chassis - Grounded outlets installed by a licensed electrician, compatible with the power cords Note: To maximize fault tolerance, connect each power cord to a separate power source. 5. Ensure that the switch fans have access to a total - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 38
minute, available in the immediate vicinity of the SAN Director 2/128. ■ If installing the switch in an HP rack, or comparable Electronics Industries Association (EIA) called the "service aisle"). This prevents the fans from pulling in heated exhaust air. 38 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 39
items are required for this setup: ■ SAN Director 2/128 ■ AC power cords and cables supplied with the switch Caution: You must remove the chassis door before lifting the chassis off the pallet. See the next section, "Removing the Chassis Door" on page 40. SAN Director 2/128 Installation Guide 39 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 40
Installing and Configuring the SAN Director 2/128 Removing the Chassis Door You must remove the chassis door before lifting the switch off the pallet. Use these steps to remove will need to reinstall it after moving the SAN Director 2/128 off the pallet. 40 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 41
the port side faces the service aisle. 1. Remove the switch chassis door, if you have not already done so. See Removing the Chassis Door, on page 40. 2. Place the SAN Director 2/128 on a flat, sturdy surface like a table or lab bench. 3. Connect the two power cables to the power supply inlets on the - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 42
or assisted lift to aid in moving the switch from the pallet to its operating location. ■ Two power outlets-identify one power outlet for each of the two power cords. Installing each power cord at two separate sources ensures power supply redundancy. 42 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 43
to configure SAN Director 2/128 network addresses and acquire event log information through the serial port. Computer requirements include: - Microsoft Windows 98®, Windows NT® 4.0, Windows 2000®, or Windows Millennium Edition® operating system installed - RS-232 serial communication software - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 44
procedure to install the SAN Director 2/128 in an HP 10,000 series, HP System/e or comparable EIA cabinet using the 14U Rack Mount Kit supplied with the switch. Allow approximately 45 minutes to complete this procedure. Note: These instructions describe how to install the switch in the bottom area - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 45
You can install up to two SAN Director 2/128 switches. HP supports up to two SAN Director 2/128 switches in an HP 10,000 series, System\e, or toward exhaust aisle (see Figure 5) and attach to cabinet rails, using six 1/4-20 x 0.500-inch (1.27 cm) screws with lock washers per bracket (two on - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 46
and Configuring the SAN Director 2/128 2 1 3 4 SHR-2509A 1 Left rack mount shelf bracket 2 Adjusting screws 3 Right rack mount shelf bracket 4 1/4-20 x .500-inch screws and washers (6) Figure 5: Installing the left and right rack mount shelf brackets 46 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 47
mount shelf bracket. Note: When finished securing the rack mount shelf brackets, remember to tighten the adjustment screws you loosened in step 3, and torque to 32 inch-pounds. SAN Director 2/128 Installation Guide 47 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 48
nuts to the two rails at the front of the rack (service aisle side). See Figure Figure 6. 1 2 3 Figure 6: Installing the retainer nuts on the rails 1 Upper retainer nuts, installed in hole #41 2 Lower retainer nuts, installed in hole #9 3 1U location 48 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 49
Installing and Configuring the SAN Director 2/128 For Rails with Round Holes-Attaching the Clip Nuts If installing the 14U Rack Mount Kit in rails with round holes, refer to this section. Attach the clip nuts to the vertical rails on the service side of the rack as follows. ■ Use the clip nuts for - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 50
upper rack mount bracket 2 #10-32 x 5/16 inch screws (4) 3 Detached L-shaped brackets (1 of 2) 4 Right flat upper rack mount bracket Figure 7: Attaching the left and right flat upper rack mount brackets 4. Tighten the screws and torque to 32 inch-pounds. 50 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 51
SAN Director 2/128 5. Attach the two L-shaped brackets to the rack rails farthest from the service aisle. See Figure 8. - For rails with square holes: Attach the two L-shaped brackets to the rack rails with two of the #1/4-20 and unplug cables from switch. SAN Director 2/128 Installation Guide 51 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 52
Installing and Configuring the SAN Director 2/128 1 2 3 SHR-2512A 1 Two L-shaped brackets 2 Aligning top screw in hole #37 3 1/4-20 x 1/2 inch Phillips panhead screws and square washers Figure 8: Attaching L-shaped brackets to rails 52 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 53
SAN Director 2/128 into the HP 10,000 series, HP System\e or comparable EIA cabinet. WARNING: A fully populated SAN Director 2/128 weighs approximately 250 lbs cards or power supplies are partially extended out of the chassis. Sliding the Switch into the Rack SAN Director 2/128 Installation Guide 53 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 54
Installing and Configuring the SAN Director 2/128 SHR-2513A Figure 9: Attaching the upper rack mount bracket to the L-shaped brackets 2. Tighten screws, and torque to 32 inch-pounds. 54 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 55
SAN Director 2/128 3. Secure the chassis port side to the rack rails using two #10-32 x 5/8 inch screws on each side. Figure 10: Securing the chassis port side to rack rails SHR-2514A 4. Tighten the screws, and torque to 32 notches to release the pins. SAN Director 2/128 Installation Guide 55 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 56
2/128, it needs to be connected prior to powering on the switch. To install a modem, refer to "Setting Up and Installing Modems" on page 153. 1. Verify that the ON/OFF switches for each 16-port card and CP card are in the ON position (see Figure 11). 56 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 57
6 c 5 b 4 a 3 d 2 c 1 b 0 a ON/OFF Switch in "ON" position ! Fibre Channel Port (16x) 2.017 Ejector (2x) Figure 11: ON/OFF switch for a 16-port card Note: The ON/OFF switch for CP cards is identical to the ON/OFF switch on the 16-port card in Figure 11. SAN Director 2/128 Installation Guide 57 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 58
AC Switch Cover (2x) Power Cord Retainer (2x) Retainer Attaching Screw (2x) scale: 5/16" = 1" 2.014 Figure 12: AC panel and power cord retainers 5. Loosen the clamping screw on each retainer, insert the power cords through the retainers into the power receptacles on the SAN Director 2/128, and - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 59
SAN Director 2/128 6. Ensure that the power cord has a minimum service loop of 6 inches available at the connection to the switch and is routed so that it is not exposed to stress. 7. Connect the power cords to a power source with voltage of 200 to 240 VAC, 50 to 60 Hz. 8. Position AC power switches - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 60
switch using a terminal emulator application (such as HyperTerminal on Windows 95®, 2000®, or NT®, or TERM in a UNIX® environment). Note: The SAN Director 2/128 supports - Bits per second: 9600 - Databits: 8 - Parity: None - Stop bits: 1 - Flow control: None 60 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 61
Configuring the SAN Director 2/128 6. When the terminal emulator application stops reporting information, press Enter. 7. Log in to the switch as admin. The default password is password. Note: At the initial login, the user is prompted to enter new admin and user passwords. 8. Modify passwords, if - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 62
cables down through the holes in the management tray requires minimum of 3U (rack units) below the switch. ■ Cable Guides (Pillars)-A set of 16 cable guides (pillars) are provided with the SAN Director 2/128 and can be used to organize the port cables into logical groups, such as according to port - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 63
of the cards, not across adjacent cards or in front of the power supplies. Figure 14 provides an example in which cables for each card switches, while preserving in-order delivery. For more information, refer to the HP StorageWorks Features 4.2.x User Guide. SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 64
in transmitting data, a minimum length is required for cables that connect the SAN Director 2/128 ports to device ports, as follows: ■ 9 microns, single-mode (SM) - 2 meters ■ 50 microns, multimode (M5) - 2 meters ■ 62.5 microns, multimode (M6) - 2 meters 64 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 65
10 c 9 b 8 a 7 d 6 c 5 b 4 a 3 d 2 c 1 b 0 a ! ! POWER SUPPLY 3 ! ! POWER SUPPLY 2 ! ! POWER SUPPLY 1 & 3 POWER SUPPLY 2 & 4 200-240 VAC 12A 50-60 Hz 200-240 VAC 12A 50-60 Hz scale: 1/4" = 1" Figure 14: Effective cable management POWER SUPPLY 1 SAN Director 2/128 Installation Guide 2.033 65 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 66
the switch is stored in the WWN card and the flash switch name (see "Customize a Switch Name" on page 73). 5. Set up switch status policies (see "Specify Status Policies" on page 74). 6. Specify domain ID for the switch (see "Set the Domain ID" on page 75). 66 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 67
necessary (refer to "Enable Software Licenses" on page 78). 9. Back up the configuration (refer to "Back Up the Configuration" on page 79). Refer to the HP StorageWorks Fabric OS 4.2.x Command Reference Guide for additional information about these commands. SAN Director 2/128 Installation Guide 67 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 68
switch. The default IP addresses and host names for the SAN Director 2/128 default information for the CP card in slot 5 is displayed. Example: Ethernet IP Address [10.77.77.75]: Ethernet Subnetmask [255.0.0.0]: Host Name [CP0]: Gateway Address [0.0.0.0]: 68 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 69
Installing and Configuring the SAN Director 2/128 Note: The host name is the name assigned to the CP card. The same gateway address must be used for both IP address of the standby CP card. The IP address of the standby CP card is updated at the next reboot. SAN Director 2/128 Installation Guide 69 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 70
SAN Director 2/128 Configure IP Address for the Switch The SAN Director 2/128 has its own IP address and corresponding subnet mask. The default IP address is 10.77.77.77. Caution: Resetting an IP address while the SAN Director 2/128 the shipping cap. 70 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 71
the available management tools, such as telnet or Fabric Manager. 4. To complete any additional SAN Director 2/128 configuration procedures through a telnet session, log in to the switch by telnet, using the admin login. The default password is "password". SAN Director 2/128 Installation Guide 71 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 72
:admin> switchName "sw10" For details about the switchname command, refer to the HP StorageWorks Fabric OS 4.2.x Command Reference Guide. 2. Record the new name for future reference. Note: Changing the name causes a domain address format RSCN to be issued. 72 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 73
command, refer to the HP StorageWorks Fabric OS 4.2.x Command Reference Guide. 2. Complete the prompts to specify the desired policies. Note: To completely deactivate an alarm for a particular condition, enter "0" at the corresponding prompt. SAN Director 2/128 Installation Guide 73 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 74
and Configuring the SAN Director 2/128 Set the Domain ID Each switch in the fabric must have a unique Domain ID. The Domain ID can be set using the configure command. It is also possible to allow the Domain ID to be automatically set. Note: The default Domain ID for the SAN Director 2/128 is "1". To - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 75
SAN Director 2/128 to the fabric, verify that all the switches in the fabric use the correct port identifier (PID) settings. For information on setting the PIDs, refer to the HP StorageWorks Fabric OS 4.2.x Procedures User Guide. To connect the SAN Director 2/128 oriented. For instructions that are - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 76
command, refer to the HP StorageWorks Fabric OS 4.2.x Command Reference Guide. 8. To establish additional system parameters, use the configure command. For details about this command, refer to the HP StorageWorks Fabric OS 4.2.x Command Reference Guide. 76 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 77
SAN Director 2/128. The chassis ID is available through the command licenseidShow. Both the licenseShow and licenseidShow commands must be entered through the active CP card. For information about activating licenses, refer to the HP StorageWorks Fabric OS 4.2.x Procedures User Guide. SAN Director - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 78
switch, if necessary. For more information about this command, refer to the HP StorageWorks Fabric OS 4.2.x Command Reference Guide. Note: Refer to the HP StorageWorks Fabric OS 4.2.x Procedures User Guide for information about using the configdownload command. 78 SAN Director 2/128 Installation - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 79
Boot Results, page 100 ■ Diagnostics, page 102 ■ Troubleshooting the SAN Director 2/128, page 103 Refer to the following sections for LED and CLI information about each SAN Director 2/128 component: ■ 16-Port Cards, page 82 ■ CP Cards, page 86 ■ Power Supplies, page 89 ■ Blower Assemblies, page 92 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 80
change during POST and other diagnostic tests. For information about how to interpret the LED patterns, refer to Table 6. 2. Check the 16-port card status using the slotshow command (see Obtaining Chassis and Component Status, page 99 for an example). 80 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 81
Status LED (16x) scale: 5/16" = 1" ! 15 d 14 c 13 b 12 a 11 d 10 c 9 b 8 a 7 d 6 c 5 b 4 a 3 d 2 c 1 b 0 a ON/OFF Switch in "ON" position ! Fibre Channel Port (16x) Ejector (2x) Figure 15: Front of 16-port card 2.017 Operating the SAN Director 2/128 SAN Director 2/128 Installation Guide 81 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 82
, consult switch supplier. Pull card out and reseat it. If LED continues to flash, replace card. Check for out-of-bounds environmental condition and correct it. Verify that the power LED is on. Use portcfgspeed command to change mode. No action required. 82 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 83
to diagnostic tests or portdisable command. Transceiver or port is faulty. No action required. No action required. Reset port from workstation. Change transceiver or reset switch from workstation. Port is bypassed. Reset port from workstation. SAN Director 2/128 Installation Guide 83 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 84
Operating the SAN Director 2/128 CP Cards To determine the status of a CP card: 1. Check the LED indicators on the port card (see Figure 16). The LED patterns may temporarily change during POST and Status" on page 99 for an example) and hashow command. 84 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 85
SAN Director 2/128 For additional information about these commands, refer to the HP StorageWorks Fabric OS 4.2.x Reference Manual. ON/OFF Switch (in "ON" position) ON/OFF Switch in "OFF" position RS - 232 Power LED ! Status LED RS-232 Modem Port IOIOI Link Status LED Link Speed LED 10/100 Mb - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 86
has power, Ethernet cable is firmly seated, and connected device is functioning. No action required. Ensure CP has power. Note: To force a persistent Ethernet link speed, use the ifmodeset command. No action required. No action required. No action required. 86 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 87
the psshow command (see "Obtaining Chassis and Component Status" on page 99 for an example). The power supply status displays OK, Absent, or Faulty. If a power supply is absent or faulty, contact the switch supplier to order replacement parts, as necessary. SAN Director 2/128 Installation Guide 87 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 88
Operating the SAN Director 2/128 Power Supply ! ! scale: 3/16" = 1" Locking Tab scale: 3/8" = 1" Handle Power LED ! Predictive ! Failure LED Fail LED Front of Power Supply Figure 17: Power supply LEDs 2.019 88 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 89
. Check the power LED. Verify that the correct AC power switch is on and power supply is seated. If orange light continues, replace power supply. Verify that the incoming power meets power requirements (refer to "Technical Specifications" on page 163). SAN Director 2/128 Installation Guide 89 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 90
Operating the SAN Director 2/128 Blower Assemblies To determine the status of a blower assembly: 1. Check the LED assembly is also provided. If a blower assembly is absent or faulty, contact the switch supplier to order replacement parts, as necessary. 90 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 91
additional information about these status indicators, refer to the HP StorageWorks Fabric OS 4.2.x Reference Manual. scale: 1/8" = 1" Power LED Blower Assembly Fault LED Handle scale: 1/4" = 1" Captive Screw (2x) 2.020 Figure 18: Blower assembly LEDs SAN Director 2/128 Installation Guide 91 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 92
blower assembly has incoming power. Replace blower assembly. Pull unit out and reseat. If LED continues to flash, replace unit. Check for out-of-bounds environmental condition, resolve any problems, and reseat unit. If LED continues to flash, replace unit. 92 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 93
and power values switch Related Commands wwn, chassisshow chassisshow ipaddrshow, ipaddrset historyshow, historylastshow switchname Note: For additional information about these commands, refer to the HP StorageWorks Fabric OS 4.2.x Command Reference Guide. SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 94
present 0x24c (fabos): Switch: switchname, Error EM-HIL_FAIL, 2, HIL Error: hilSetFruHistory failed, rc=-3 for SLOT 3 Note: For more information about error messages, refer to the HP StorageWorks Diagnostic and System Error Messages 4.2.x Reference Manual. 94 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 95
up. Power supply Power/Status Steady green Steady amber Power is OK. No action required. Power supply is faulty. Check power supply. Note: If a Status LED on the WWN bezel flashes, the Power LED on the WWN bezel also flashes, for increased visibility. SAN Director 2/128 Installation Guide 95 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 96
the switch or power the entire chassis off/on. If the problem is still unresolved after these steps, contact your support provider. The information required by your support provider in order to provide assistance is listed under "Getting Help" on page 14. 96 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 97
fans chassisshow Serial number, time awake, and additional information about each component slotshow Slot occupancy errshow Switch error log (lists status of any marginal/failed components) Note: Enter CLI commands with all lowercase characters. SAN Director 2/128 Installation Guide 97 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 98
about error messages, refer to the HP StorageWorks Diagnostic and System Error Messages 4.2.x Reference Manual. POST includes the following steps: ■ Preliminary POST diagnostics are run. ■ Operating system is initialized. ■ Hardware is initialized. 98 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 99
■ Fabric is analyzed. If any ports are connected to other switches, the switch participates in a fabric configuration. ■ The switch obtains a domain ID and assigns port addresses. ■ Unicast routing tables are constructed. ■ Normal port operation is enabled. SAN Director 2/128 Installation Guide 99 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 100
the SAN Director 2/128 Diagnostics Diagnostic tests are automatically run during POST to check the status of the switch. Any error messages generated during POST are sent to the error logs and to the serial console, if connected. Diagnostic tests can also be run manually to test and troubleshoot the - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 101
Table 14: Troubleshooting the SAN Director 2/128 Issue Entire chassis powers off automatically. Several or all components are not operating. Serial connection is faulty or serial port logs have incorrect or missing information. Possible Cause Power supplies are inadequate to support the installed - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 102
speed by entering the ifmodeset command. Install an operational WWN card and power the system off/on again. Refer to "Initial Configuration Parameters" on page 67 and the HP StorageWorks Fabric OS 4.2.s Procedures User Guide for configuration information. 102 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 103
are visibly damaged, as this could damage pins on other component. Replace parts as required. Ensure that the SAN Director 2/128 has power and component is firmly seated. If problem continues, run the sensorshow command to determine component status. If component is a CP card or port card, enter - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 104
the SAN Director 2/128 Table 14: Troubleshooting the SAN Director 2/128 (Continued) Issue One or more 16-port cards have either shut down or failed POST as indicated by the error log. An individual component is not operating as expected. Possible Cause 16-port cards might be overheated. 16-port - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 105
Guides (Pillars), page 112 ■ Replacing a 16-Port Card and Filler Panel, page 113 ■ Replacing a CP Card, page 123 ■ Replacing a Power Supply and Filler Panel, page 137 ■ Replacing a Blower Assembly, page 140 ■ Replacing the WWN Bezel and Card, page 143 SAN Director 2/128 Installation Guide 105 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 106
. 1. Remove the chassis door from the SAN Director 2/128: a. Open the door to an angle of approximately 90 degrees. b. Support the door to prevent it from falling. Push the spring-loaded pin on the upper hinge up and into the notch in the hinge (see Figure 20), and push the spring-loaded pin on - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 107
Installing SAN Director 2/128 FRUs scale: 3/8" = 1" 2.011 To Release To Lock Door portion of upper hinge with pin in notch Door portion of upper hinge with pin out of notch (Pin released) Figure 20: Upper door hinge Chassis portion of upper hinge SAN Director 2/128 Installation Guide 107 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 108
The procedure requires a #2 Philips screwdriver. The SAN Director 2/128 can continue to operate during the installation. Note: Do not use a power screwdriver on the cable management tray. 1. Remove the cables through or along the tray, as required. 108 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 109
3 200-240 VAC 12A 50-60 Hz POWER SUPPLY 2 & 4 200-240 VAC 12A 50-60 Hz POWER SUPPLY 4 POWER SUPPLY 3 ! ! POWER SUPPLY 2 ! ! POWER SUPPLY 11 Cable Management Tray Attaching Screw (2x) Ground Strap Connector Figure 21: Cable management tray 2.026 SAN Director 2/128 Installation Guide 109 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 110
Installing SAN Director 2/128 FRUs Replacing the Cable Guides (Pillars) The cable guides (pillars) can be used to organize the port cables into logical groups, such as port quads (sets of four neighboring ports). The cable pillars do - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 111
of the SAN Director 2/128 also displays a power and status LED for each 16-port card. 2. Establish a telnet or console session. Before replacing a 16-port card, establish a telnet or console connection to determine a failure and verify operation after replacement. Refer to the HP StorageWorks Fabric - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 112
the steps in the following sections to replace a 16-port card. The procedure requires: ■ An ESD (electrostatic discharge) grounding strap ■ Workstation computer ■ Replacement port card or filler panel ■ SFP transceivers (as needed) ■ SFP cables (as needed) 112 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 113
! POWER SUPPLY 2 ! ! POWER SUPPLY 11 16 Port Card ! 15 d 14 c 13 b 12 a 11 d 10 Switch c 9 in OFF b 8 a (down) 7 d 6 position c 5 b 4 a 3 d 2 c 1 b 0 a scale: 5/32" = 1" Ejector (2x) Figure 22: 16-port card removal and replacement 2.004 SAN Director 2/128 Installation Guide 113 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 114
for the Power LED to turn off in response to the hot-swap request before uninstalling the 16-port card. 5. Unscrew the captive screws from both handles. 6. Lever both ejectors open to approximately 45 degrees, and pull the 16-port card out of the chassis. 114 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 115
SAN Director 2/128 FRUs Note: If you inadvertently relatch the ejectors prior to the 16-port card being removed, wait at least one second prior to unlatching the ejectors again. 7. If the card is not being replaced by another 16 panel out of the chassis. SAN Director 2/128 Installation Guide 115 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 116
! ! Attach Captive POWER SUPPLY 2 Screw ! ! POWER SUPPLY 11 POWER SUPPLY 1 & 3 200-240 VAC 12A 50-60 Hz POWER SUPPLY 2 & 4 200-240 VAC 12A 50-60 Hz Filler Panel Captive Screw (2x) Handle Figure 23: Removing and replacing a filler panel 2.005 116 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 117
the handles seats the 16-port card in the slot. 4. Verify that the Power LED on the 16-port card is displaying a steady green light (it can take a few seconds to turn on). If it does not turn on, ensure that the 16-port card has power and is firmly seated. SAN Director 2/128 Installation Guide 117 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 118
Installing SAN Director 2/128 FRUs Note: The LED patterns may temporarily change during POST and other diagnostic tests. 5. Install SFP transceivers and cables in the 16-port card, as CLI, refer to the HP StorageWorks Fabric OS 4.2.x Procedures User Guide. 118 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 119
2 1 POWER SUPPLY 4 POWER SUPPLY 3 ! ! POWER SUPPLY 2 POWER SUPPLY 1 & 3 200-240 VAC 12A 50-60 Hz POWER SUPPLY 2 & 4 200-240 VAC 12A 50-60 Hz ! ! POWER SUPPLY 1 Alignment Groove ! scale: .13865" = 1" Figure 24: Card guides inside each card slot SAN Director 2/128 Installation Guide 2.0 119 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 120
Panel 1. Align the flat side of the filler panel inside the upper and lower rail guides in the slot (see Figure 24); then, slide the filler panel into the slot (with slight pressure to the left) until it is firmly seated. 2. Tighten the two captive screws. 120 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 121
of a CP card voids the part warranty and regulatory certifications. There are no user-serviceable parts inside a CP card. To ensure adequate system pressure for cooling purposes, leave the has a different version, update cards to the same firmware version. SAN Director 2/128 Installation Guide 121 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 122
to replace a CP card. Locate the following items prior to installation: ■ ESD grounding strap ■ Workstation computer ■ Serial cable provided with the SAN Director 2/128 ■ IP address of an FTP server for backing up the SAN Director 2/128 configuration 122 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 123
12A 50-60 Hz POWER SUPPLY 4 POWER SUPPLY 3 ! ! POWER SUPPLY 2 ! ! POWER SUPPLY 11 CP Card ! RS - 232 IOIOI Switch in OFF 1Li0n/k100 Mb/s Active CP (down) position 2.003 scale: 5/32" = 1" Ejector (2x) Figure 25: CP card removal and replacement SAN Director 2/128 Installation Guide 123 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 124
problem with a CP card - Function fail messages for the CP master Recording Critical Switch Information Back up the switch configuration before replacing a CP card. To record critical switch can be removed to allow for a serial RJ45 connection. 124 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 125
SAN Director 2/128 FRUs d. Open the terminal emulator application and configure as follows: - Bits per second: 9600 - Databits: 8 - Parity: None - Stop bits For more information about commands, refer to the HP StorageWorks Fabric OS 4.2.x Command Reference Guide. 5. If the healthy CP card is also - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 126
the serial console for the healthy (and active) CP card, back up the current configuration: a. Enter the configupload command. Note: The configupload command uploads the switch configuration to a specified FTP server. 126 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 127
90 User Name [None]: user File Name [config.txt]: config.txt Password: upload complete swDir:admin> 9. Log in to the SAN Director 2/128 and back up the current configuration: a. From the serial console for (modem, serial, Ethernet) from the faulty CP card. SAN Director 2/128 Installation Guide 127 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 128
request before uninstalling the CP card. Caution: Do not remove the CP card until the Power LED is off. Also, hold CP cards by the edges of the metal pans, not screws. 5. Slide the CP card ON/OFF switch in the upper handle up (covering the captive screw). 128 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 129
Installing SAN Director 2/128 FRUs 6. Verify that the Power LED is green (might require a few seconds). If not, ensure that the CP card has power, is firmly seated, and the ejectors are ): Standby HA Enabled, Heartbeat Up, State Synchronized swDir:admin> SAN Director 2/128 Installation Guide 129 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 130
ON 10 UNKNOWN VACANT swDir:admin> 3. Determine the firmware version (enter the firmwareshow command). swDir:admin> firmwareshow Primary partition: v4.2.0meteor_pit_02_031204_0722 Secondary Partition: v4.2.0meteor_pit_02_031204_0722 swDir:admin> 130 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 131
Installing SAN Director 2/128 FRUs 4. If the firmware version of the replacement card does not match that of the active CP card, bring the replacement card to the same firmware level as the active card. Check with the switch supplier for supported versions. Download the firmware, using either of the - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 132
you have specified nondefault values. To do this, enter the configshow command followed by a text string (in quotes) that relates to the parameter: for example, configshow fabric. This limits the command output to entries that contain that text string. 132 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 133
Installing SAN Director 2/128 FRUs Note: Entering the configshow command without a filter prints out approximately 1000 lines. For more information about this command, refer to the HP StorageWorks Fabric OS 4.2.x Command Reference Guide. swDir:admin> configshow "fabric" fabric.domain:2 fabric. - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 134
complete swDir:admin> swDir:admin> switchenable 10 9 8 7 6 5 4 3 2 1 fabric: Principal switch fabric: Domain 1 12. Package the faulty CP card in the packaging provided with the new CP card, and contact the switch supplier to determine the return procedure. 134 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 135
chassis operating will be available throughout the replacement. If adequate power will not be consistently available, shut down the SAN Director 2/128 gracefully, as follows: a. Open a telnet session to the active CP card and log in to the switch as admin. SAN Director 2/128 Installation Guide 135 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 136
both AC switches are flipped to "1" (AC switch lights up green). 5. If the chassis was powered down, flip both AC power switches to "1". The AC power switches light up green when power is being supplied, and the SAN Director 2/128 performs POST by default. 136 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 137
2 & 4 200-240 VAC 12A 50-60 Hz POWER SUPPLY 4 POWER SUPPLY 3 ! ! POWER SUPPLY 2 POWER SUPPLY 11 scale: .13865" = 1" Lip Power Supply #1 Power Supply Cover Locking Tab ! ! Handle (unlocked) Figure 26: Power supply removal and replacement 2.002 SAN Director 2/128 Installation Guide 137 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 138
instructions for replacing a SAN Director 2/128 blower assembly. The SAN Director 2/128 and regulatory certifications. There are no user-serviceable parts inside the blower assembly. Use two assemblies are functioning correctly. The blower assembly Power LED should be steady green and the Fault LEDs - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 139
, ensure that it is properly oriented. b. Verify that the Power LED displays a green light; if not, ensure that the blower assembly is correctly seated. c. Push the top of the handle into the recess. d. Tighten the self-retaining screws to finger-tight. SAN Director 2/128 Installation Guide 139 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 140
Installing SAN Director 2/128 FRUs Chassis Captive Screw (2x) 1 2 3 4 5 6 7 8 9 10 pwr4 pwr3 pwr2 pwr1 2.007 scale: 5/32" = 1" Blower Assembly Figure 27: Blower assembly removal and replacement 140 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 141
a consolidated view of the 16-port card status, CP card status, and power supply status. For information about how to interpret the LED patterns, refer to Table 15. Note: The LED patterns might temporarily change during POST and other diagnostic tests. SAN Director 2/128 Installation Guide 141 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 142
to the HP StorageWorks Fabric OS 4.2.x Command Reference Manual. Table 16: Messages Switch: switchname, Error EM-WWN_ABSENT, 2, WWN not present 0x24c (fabos): Switch: switchname, Error EM-HIL_FAIL, 2, HIL Error: hilSetFruHistory failed, rc=-3 for SLOT 3 142 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 143
systems.) Caution: Do not power cycle or reboot the SAN Director 2/128 or replace the CP cards contains no user-serviceable parts. Figure 28 shows the nonport side of the SAN Director 2/128, which contains or a serial console session with the SAN Director 2/128. If a serial console session is used - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 144
the WWN card voids the part warranty and regulatory certifications. The WWN card contains no user-serviceable parts. 1. Open a CLI session (telnet or serial) to the SAN Director 2/128 and log in as admin. The default password is "password". - To login by telnet Fabric OS (swDir) swDir login: admin - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 145
Installing SAN Director 2/128 FRUs d. Connect the other end of the serial cable to a serial port on the workstation. If necessary, remove the adapter on the serial cable to allow for a serial RJ45 connection. e. Open the terminal emulator application and configure as follows: - Bits per second: 9600 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 146
Installing SAN Director 2/128 FRUs b. All the LEDs on the WWN bezel turn off. swDir>admin>frureplace wwn This is the WWN card hot swap interface. Continuing from this point will require the whole process to be completed. If this process is not complete due to system fails-over, or CP power cycled, - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 147
Installing SAN Director 2/128 FRUs Installing a WWN Card Use these steps to install a new WWN card. 1. Unpack the new WWN card and save the correct installation) and use the "Push Pad" to press the card onto the connector gently, until it is fully seated. SAN Director 2/128 Installation Guide 147 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 148
SAN Director 2/128 FRUs Alternate WWN Card Handle (2x) Bezel WWN Card 1 2 3 4 5 6 7 8 9 10 pwr4 pwr3 pwr2 pwr1 PUSH Push Pad Captive Screw (2x) PULL WWN Connector .15625" = 1" scale: 5/32" = 1" Figure 28: WWN Bezel and card removal and replacement 148 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 149
Installing SAN Director 2/128 FRUs Caution: Do not force the installation. If the part does not install easily, ensure that it is properly . 4. Pack the faulty WWN card in the packaging provided with the new card and return it to the switch supplier. SAN Director 2/128 Installation Guide 149 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 150
Installing SAN Director 2/128 FRUs 150 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 151
is required to use modems with the SAN Director 2/128. Caution: The SAN Director 2/128 detects modems only during power-on, reboot, or a CP card failover sequence. HP recommends setting up the modems before powering on the SAN Director 2/128. For increased security, any active modem sessions - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 152
on the seventh ring and allows login to proceed. Note: If a modem connection is set up, connecting a modem to each CP card is recommended. 152 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 153
c 5 b 4 a 3 d 2 c 1 b 0 a ! ! POWER SUPPLY 3 ! ! POWER SUPPLY 2 ! ! scale: 1/8" = 1" POWER SUPPLY 1 & 3 POWER SUPPLY 2 & 4 200-240 VAC 12A 50-60 Hz 200-240 VAC 12A 50-60 Hz POWER SUPPLY 1 Figure 29: Two modems attached for high availability 2.015 SAN Director 2/128 Installation Guide 153 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 154
modem ports is recommended. 1. Power off the SAN Director 2/128. 2. Set up the two modem units and corresponding power connections, but do not power on the modems until all cables are attached. 3. Connect the modem cables to the modems and to the SAN Director 2/128 RS-232 modem ports. 4. Connect - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 155
Setting Up and Installing Modems 9. Power on the SAN Director 2/128, or reboot if it was not powered off during the previous steps. This allows the SAN Director 2/128 to recognize the modems. SAN Director 2/128 Installation Guide 155 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 156
procedure is only required if a dial-out modem facility is not already available for testing the SAN Director 2/128 modem connections. To set up the optional remote modem: 1. Connect the remote modem to the Modem Cable 2.016 Figure 30: Remote modem setup 156 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 157
Databits 8 Parity None Stop bits 1 Modulation Standard *Port usually defaults to highest speed supported by modem; might negotiate for slower speed. 4. Follow the instructions from the modem manufacturer to set up and verify modem operation. SAN Director 2/128 Installation Guide 157 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 158
(usually in slot 5) lights the "Off Hook" (OH) indicator on the modem and a login prompt is presented to the remote client. 8. Log in to the switch from the remote client as admin. The default password is "password". 158 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 159
while a session is active. 11. Dial in to the telephone number assigned to the SAN Director 2/128, as described in "Setting Up a Remote Modem System" on page 158. 12. Observe the modem lamps: the Ring indicator should flash only on the modem connected to the standby CP card. 13. Verify that after - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 160
Setting Up and Installing Modems 160 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 161
, page 165 ■ System FRU Weights, page 166 ■ Facility Requirements, page 167 ■ Power Specifications, page 168 ■ Environmental Requirements, page 169 ■ Power Cords, page 170 ■ Fibre Channel Port Specifications, page 174 ■ CP Card Specifications, page 175 SAN Director 2/128 Installation Guide 161 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 162
optic cable and port speed Simple Name Server; Registered State Change Notification (RSN); Alias Server (multicast); Advanced Zoning; Web Tools; Fabric Watch; Extended Fabrics; Remote Switch; ISL Trunking; End-to-End Performance Monitoring 162 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 163
Depth (with door) System Size 17.22 inches (43.74 cm) 24.11 inches/14U (61.24 cm) 27.90 inches (70.90 cm) 29.20 inches (74.20 cm) Weight 128-port configuration 250 lb (113 kg) 32-port configuration 193 lb (88 kg) Empty chassis 104 lb (47 kg) SAN Director 2/128 Installation Guide 163 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 164
Filler panel (16-port card) Power supply Blower assembly Chassis door Cable management tray WWN bezel Weight 104 lb (47 kg) 7.2 lb (3.3 kg) 6.7 lb (3.0 kg) 3.2 lb (1.5 kg) 7.0 lb (3.2 kg) 8.8 lb (4.0 kg) 7.6 lb (3.5 kg) 0.6 lb (0.3 kg) 0.6 lb (0.3 kg) 164 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 165
■ An air flow of at least 350 cubic feet per minute, available in the immediate vicinity of the SAN Director 2/128 ■ The power specifications listed in Table 20 ■ If the SAN Director 2/128 will be installed in an EIA rack, ensure the following: - All equipment installed in the rack has a reliable - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 166
loaded system has eight 16-port cards, two CP cards, and three blower assemblies. WARNING: Make sure to disconnect both power cables to remove all power from the SAN Director 2/128. Table 20: Power. Specifications Specification Value Input Voltage A fully loaded switch requires a maximum of 750 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 167
During Nonoperation -25× to +70× Celsius outside switch (-13× to 158× Farenheit) 10% to 85% RH noncondensing, at 70° Celsius 0 to 12 km (40,000 ft.) above sea level 20G, 11MS duration, sq. wave 10G, 0-5 kHz at 1.0 octave/min. None required. Not applicable. SAN Director 2/128 Installation Guide 167 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 168
NEMA L6-20 North America CEE-7/7 "Schuko" Continental Europe BS-1363 United Kingdom AS 3112 Australia/ New Zealand IEC-60309 6A-6h, 230 V~ Country Argentina Australia Austria Bahrain Belgium Brazil X Chile X China, People's Rep. 168 X X X X X X SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 169
IEC-60309 6A-6h, 230 V~ Country Czech, Rep. of Denmark Egypt England Finland France Germany Greece Hong Kong Hungary India Indonesia Ireland, North Ireland, South Israel Italy Japan Korea, South X X X X X X X X X X X X X X X X X X X SAN Director 2/128 Installation Guide 169 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 170
6h, 230 V~ Country Malaysia Mexico X Monaco Netherlands New Zealand Norway Poland Portugal Puerto Rico X Russia Saudi Arabia Scotland Singapore South Africa Spain Sweden Switzerland Taiwan X 170 Alternate X X X X X X X Recommended X X X X X X X SAN Director 2/128 Installation - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 171
-20 North America CEE-7/7 "Schuko" Continental Europe BS-1363 United Kingdom AS 3112 Australia/ New Zealand IEC-60309 6A-6h, 230 V~ Country Turkey X United Arab X Emirate United X Kingdom / Ireland United States X X Venezuela X Yugoslavia X SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 172
SAN Director 2/128 support full duplex link speeds at 2.125 or 1.0625 Gb/s inbound and outbound, automatically negotiating to the highest common speed of all devices connected to the port. Each port has a SerDes (serializer/deserializer) that accepts 10-bit 172 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 173
: ■ Main memory: 256 MB SDRAM (32 bits wide) ■ Flash memory: - User flash: 16 MB of 16-bit wide memory, stored in two 8-MB banks - Compact flash: 256 MB, partitioned in two 128-MB sections ■ Boot flash: 512 KB of 8-bit for system boot The centralized memory maximizes the overall switch throughput by - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 174
a "DB-9" male connector and an RS-232 signal subset. Note: Keep serial port covered when data bits, no parity, 1 stop bit, with no flow control. A 10 ft. (3.0 m) serial cable ships with the switch; it ---- 7 ---- ---- 8 ---- ---- 9 ---- ---- 174 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 175
be used for attaching a modem to each CP card. The SAN Director 2/128 detects modems only during the power-on or reboot sequences, and automatically initializes them for operation. If modems are connected to an operating switch, a power on/off cycle, reboot, or fast reboot is required to detect the - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 176
Technical Specifications 176 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 177
removing them from their containers. ■ Avoid touching pins, leads, or circuitry. ■ Always make sure you are properly grounded when touching a static-sensitive component or assembly. SAN Director 2/128 Installation Guide 177 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 178
Use conductive field service tools. ■ Use a portable field service kit with a HP authorized reseller install the part. Note: For more information on static electricity, or for assistance with product installation, contact your HP authorized reseller. 178 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 179
radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in authority to operate the equipment. Regulatory Series Number: HSTNM-N002 SAN Director 2/128 Installation Guide 179 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 180
-3-3)-Power Line Flicker ■ EN 60950 (IEC 60950)-Product Safety Germany Noise Declaration Schalldruckpegel Lp = 46.1 dB(A)Am Arbeitsplatz (operator position) Normaler Betrieb (normal operation)Nach ISO 7779:1999 (Typprüfung) VCCI EMC Statement (Japan) 180 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 181
RRL EMC Statement (Korea) Regulatory Compliance Notices SAN Director 2/128 Installation Guide 181 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 182
as a Class 1 Laser product, conforming to the requirements contained in Department Of Health and Human Services (DHHS) regulation 21 CFR, Subchapter J. The certification is indicated by a label on the metal limits established by the IEC and U.S. DHHS. 182 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 183
the module enclosure. There are no user-serviceable components inside. - Do not open controls, make adjustments, or perform procedures to the laser device other than those specified herein. - Allow only HP Authorized service technicians to repair the unit. SAN Director 2/128 Installation Guide 183 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 184
replacement or proper disposal, contact your HP authorized reseller or your authorized service provider. WARNING: Your switch contains an internal lithium manganese dioxide, system or return them to HP, your authorized HP partners, or their agents. 184 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 185
, link, or system. Usually measured in bps (bits per second). May also refer to the range of transmission frequencies available to a link or system. broadcast The transmission of data from a single source to all devices in the fabric, regardless of zoning. SAN Director 2/128 Installation Guide 185 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 186
as through telnet or SNMP, and does not involve a GUI. compact flash Flash (temporary) memory that is used in a manner similar to hard disk or network. Software: The set of parameters that guide switch operation. May include general system parameters, IP address SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 187
the principal switch, but can be assigned manually. The domain ID for an HP switch can be any integer between 1 and 239. Generally, the default domain ID is 1. E E_D_TOV Error detect time-out value. The , and can work in either one or both directions. SAN Director 2/128 Installation Guide 187 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 188
switch. FRU Field-Replaceable Unit. A component that can be replaced on site. FS Fibre Channel Service. A service that is defined by fibre channel standards and exists at a well-known address. For example, the Simple Name Server is a fibre channel service. 188 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 189
active and maintain bit, byte, and word synchronization. integrated fabric The fabric created by connecting multiple HP switches with multiple ISL cables, and configuring the switches to handle domain IDs or nonidentical parameters (such as E_D_TOVs). SAN Director 2/128 Installation Guide 189 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 190
and signaling functions. The first seven bits of the character are the comma pattern. kernel flash Flash (temporary) memory connected to the master time-out value. The minimum time that the loop master waits for a loop initialization sequence to return. 190 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 191
on the network). P N_Port Node port. A port on a node that can connect to a fibre channel port or to another N_Port in a point-to-point connection. SAN Director 2/128 Installation Guide 191 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 192
path selection The selection of a transmission path through the fabric. HP switches use the FSPF protocol. phantom address An AL_PA value that is assigned to an device that is not physically in employs direct links between each pair of communicating entities. SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 193
into the fabric. public device A device that supports arbitrated loop protocol, can interpret 8-bit addresses, and can log into the fabric. public allocation time-out value. The maximum time a frame can be delayed in the fabric and still be delivered. SAN Director 2/128 Installation Guide 193 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 194
for the switch. sequence A group of related frames transmitted in the same direction between two N_Ports. service rate The rate at which an entity can service requests. single mode The fiber optic cabling standard that corresponds to distances of up to 10 km between devices. 194 SAN Director 2/128 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 195
link between two communication ports. Switched fabric: Multiple N_Ports linked to a switch by F_Ports. Arbitrated loop: Multiple NL_Ports connected in a loop. transmission character A 10-bit character encoded according to the rules of the 8b/10b algorithm. SAN Director 2/128 Installation Guide 195 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 196
by an SNMP agent to inform the SNMP management station of a critical error. U_Port Universal port. A switch port that can operate as a G_Port, E_Port, F_Port, or FL_Port. A port is defined as a a configuration enables all zones in that configuration. 196 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 197
switch covers 58 accessory kit 35 activity, LEDs 80 air flow requirements 38, 40, 44, 167 altitude 167 ambient temperature 167 applications, supported 26 audience 10 authorized reseller, HP SAN Director 2/128 Installation Guide Index index C cabinet requirements 165 cable guides 62 cable lengths 64 - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 198
128 LEDs 86 removing 127 replacing 121 specifications 173 verifying operation of 129 CP cards determing status of 84 troubleshooting Manager 25 fabric services 162 fiber optic 20 HP authorized reseller 14 storage web site 14 technical support 14 humidity 167 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 199
sliding the switch into SAN Director 2/128 Installation Guide Index modem serial port specifications 175 modems connecting 154 installing 151 remote 156 setting up 151 verifying connection 158 monitoring options 26 N nonport side chassis view 19 O ON/OFF switch 16-port cards 56 out-of-band support - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 200
serial connection establishing 60 serial port modem 175 terminal 174 service aisle 38, 40, 44 serviceability features 22 sessions, telnet, maximum 25 shock 167 site plan 42 site planning 36 size and weight system 163 slot numbering 18 SNMP, managing by 25 200 SAN Director 2/128 Installation Guide - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 201
application configuring 60 terminal serial port specifications 174 text symbols 11 torque driver 43 SAN Director 2/128 Installation Guide transceivers supported types 34 troubleshooting 96 16-port cards 104 chassis power 101 components 104 configuration data 102 CP cards 103 Domain IDs 102 Ethernet - HP StorageWorks 2/128 | HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 202
Index 202 SAN Director 2/128 Installation Guide
Installation
Guide
hp
StorageWorks
SAN Director 2/128
Product Version:
4.2.x
Second Edition (April 2004)
Part Number:
AA-RVUSB-TE
This installation guide provides procedures for setting up, configuring, and managing the
Enterprise class SAN Director 2/128 switch.