HP StorageWorks 2/140 FW 05.01.00 and SW 07.02.00 hp StorageWorks HA Fabric Ma
HP StorageWorks 2/140 - Director Switch Manual
View all HP StorageWorks 2/140 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks 2/140 manual content summary:
- HP StorageWorks 2/140 | FW 05.01.00 and SW 07.02.00 hp StorageWorks HA Fabric Ma - Page 1
ha-fabric manager Product Version: FW V05.01.00-24/HAFM SW V07.02.00-09 Second Edition (November 2003) Part Number: AA-RUR6B-TE/958-000288-006 These Release Notes contain late-breaking and supplemental information for the HP StorageWorks High Availability Fabric Manager (HA-Fabric Manager). For the - HP StorageWorks 2/140 | FW 05.01.00 and SW 07.02.00 hp StorageWorks HA Fabric Ma - Page 2
of Hewlett-Packard. The information contained in this document is subject to change without notice. Microsoft®, Windows®, Windows XP®, and Windows 2000® are U.S. registered trademarks of Microsoft Corporation. UNIX® is a registered trademark of The Open Group. Hewlett-Packard Company shall not be - HP StorageWorks 2/140 | FW 05.01.00 and SW 07.02.00 hp StorageWorks HA Fabric Ma - Page 3
About this Document About this Document These Release Notes describe the contents of the HP StorageWorks high availability fabric manager software kit, and any last-minute additions or notes on the configuration or use of HAFM software. Be sure to read - HP StorageWorks 2/140 | FW 05.01.00 and SW 07.02.00 hp StorageWorks HA Fabric Ma - Page 4
15 ■ Port Diagnostics on All Ports is not Available When All Ports of an Edge Switch are not Installed and Enabled, page 16 ■ Open Systems Management Server, page 16 ■ Support for Speed Auto-Negotiate, page 16 ■ Losing LAN Connection to the HAFM Server When Logged into the HAFM Application, page - HP StorageWorks 2/140 | FW 05.01.00 and SW 07.02.00 hp StorageWorks HA Fabric Ma - Page 5
. Other HAFM Documentation In addition to this guide, HP provides corresponding information: ■ HP StorageWorks HA-Fabric Manager Server Installation Guide, AA-RU5FA-TE ■ HP StorageWorks HA-Fabric Manager User Guide, AA-RS2CD-TE ■ HP StorageWorks Director and Edge Switch Glossary, AA-RU5JA-TE CD-ROM - HP StorageWorks 2/140 | FW 05.01.00 and SW 07.02.00 hp StorageWorks HA Fabric Ma - Page 6
(HP StorageWorks HA-Fabric Manager Server Installation Guide) - AA-RS2CD-TE - (HP StorageWorks HA-Fabric Manager User Guide) - AA-RU5JA-TE - (HP StorageWorks Director and Edge Switch be installed. Follow the instructions to install the new version of the remote client. 6 HA-Fabric Manager - HP StorageWorks 2/140 | FW 05.01.00 and SW 07.02.00 hp StorageWorks HA Fabric Ma - Page 7
to the HAFM software, the Edge Switch 2/24, Edge Switch 2/32, Director 2/64, and Director 2/140. HAFM and Firmware Version Compatibility Table 1 lists the .00-24 05.01.00-24 HAFM Version (Minimum) 04.00.01 (HP EFCM) 04.01.02-14 (SDCM) 04.02.00-40 (HP EFCM) 04.02.00-40 (SDCM) 06.00.00-45 (HP EFCM) - HP StorageWorks 2/140 | FW 05.01.00 and SW 07.02.00 hp StorageWorks HA Fabric Ma - Page 8
an option to print or save product configuration to a file. Refer to the HP StorageWorks Embedded Web Server User Guide for more information. Before upgrading the Director 2/64 or Director 2/140 to Version 05.01.00-24, execute a CTP switchover to assure that the backup CTP card is fully functional - HP StorageWorks 2/140 | FW 05.01.00 and SW 07.02.00 hp StorageWorks HA Fabric Ma - Page 9
feature is not available in Firmware Version 05.01.00-24. Open Trunking feature will be available in a future release. Zoning is Disabled by Default The default zone on the Edge Switch 2/24, Edge Switch 2/32, Director 2/64, and Director 2/140 is disabled by default. Zoning must be configured in - HP StorageWorks 2/140 | FW 05.01.00 and SW 07.02.00 hp StorageWorks HA Fabric Ma - Page 10
prevents ports from accessing devices outside their zones. Hard Zoning is enabled by default when using firmware Version 05.01.00-24 or greater and cannot be disabled. All HP-approved host bus adapters (HBAs) limit access to devices within their zones, so you will not see a change in fabric behavior - HP StorageWorks 2/140 | FW 05.01.00 and SW 07.02.00 hp StorageWorks HA Fabric Ma - Page 11
counter value exceeded over a specified time duration. Note: The CTA configuration is cleared upon downgrade to firmware below 05.01.00. SNMP Changes Firmware Version 05.01.00-24 supports the following management information base (MIB) versions on all products: ■ Fabric Element MIB: V1.1 ■ MIB-II - HP StorageWorks 2/140 | FW 05.01.00 and SW 07.02.00 hp StorageWorks HA Fabric Ma - Page 12
Please consult with HP Professional Services or your support representative if you have questions regarding specific zone set configurations. Using the Same Firmware All switches and directors in the same fabric should have the same FW level installed-whether 1 Gbps or 2 Gbps capable. 12 HA-Fabric - HP StorageWorks 2/140 | FW 05.01.00 and SW 07.02.00 hp StorageWorks HA Fabric Ma - Page 13
edge switch to regain use of the licensed features (e.g., SANtegrity Binding). CTP Controls Port Lights Port lights on the edge switch in the LCD screen of the 1U server in the HP StorageWorks HA-Fabric Manager Server Installation Guide. The LCD screen displays the following information: ■ Host - HP StorageWorks 2/140 | FW 05.01.00 and SW 07.02.00 hp StorageWorks HA Fabric Ma - Page 14
minutes the screen displays "Welcome". Regulatory Information The following regulatory information was erroneously omitted from the HP StorageWorks HA-Fabric Manager Server Installation Guide. TELECOMMUNICATIONS NOTICE FOR JAPAN The modem supplied with this equipment, part number MT5634ZPX-PCI, is - HP StorageWorks 2/140 | FW 05.01.00 and SW 07.02.00 hp StorageWorks HA Fabric Ma - Page 15
panel may be blank. Workaround Going to a different view first, e.g., Product View or Hardware View for a director or edge switch, will prevent this from occurring. Director and Edge Switch may be Displayed With WWN even if Display Option "Product Name" is Selected In the Fabric View, the directors - HP StorageWorks 2/140 | FW 05.01.00 and SW 07.02.00 hp StorageWorks HA Fabric Ma - Page 16
Known Issues Port Diagnostics on All Ports is not Available When All Ports of an Edge Switch are not Installed and Enabled The Edge Switch 2/24 and Edge Switch 2/32 basic units have 8- and 16-ports installed, respectively. The remaining ports can be enabled by purchasing additional ports and - HP StorageWorks 2/140 | FW 05.01.00 and SW 07.02.00 hp StorageWorks HA Fabric Ma - Page 17
the HAFM application must be restarted. Stopping the HAFM application has no impact on the Fibre Channel operations of any switch or director. Monitoring switch operations, logging events, and implementing configuration changes are interrupted only while the LAN is not connected. Effect of No LAN - HP StorageWorks 2/140 | FW 05.01.00 and SW 07.02.00 hp StorageWorks HA Fabric Ma - Page 18
edge switches that the HAFM server manages ■ Computers seeking remote client access to the HAFM server ■ SAN management applications such as hp OpenView SAN Though the directors and edge switches can be managed via either LAN, the public LAN is the only one that can support remote client access. Thus - HP StorageWorks 2/140 | FW 05.01.00 and SW 07.02.00 hp StorageWorks HA Fabric Ma - Page 19
listen for remote client connections). To configure this feature, you must manually edit a file on the HAFM server to explicitly specify which impact the Fibre Channel operations of any edge switch or director. Only monitoring switch operations, logging events, and implementing configuration
release notes
hp
StorageWorks
ha-fabric manager
Product Version:
FW V05.01.00-24/HAFM SW V07.02.00-09
Second Edition (November 2003)
Part Number:
AA–RUR6B–TE/958–000288–006
These Release Notes contain late-breaking and supplemental information for the
HP StorageWorks High Availability Fabric Manager (HA-Fabric Manager).
For the latest version of these Release Notes and other HA-Fabric Manager documentation,
access the HP storage website at:
.