HP StorageWorks 2/140 FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks Director Re
HP StorageWorks 2/140 - Director Switch Manual
View all HP StorageWorks 2/140 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks 2/140 manual content summary:
- HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks Director Re - Page 1
HP StorageWorks Director release notes Part number: AA-RTDVH-TE/958-000276-008 Eighth edition: (August 2005) - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks Director Re - Page 2
trademarks of Microsoft Corporation. Hewlett-Packard Company shall not be liable for technical or editorial errors or omissions contained herein. The information is provided "as is" without warranty of any construed as constituting an additional warranty. Printed in the U.S.A. Director release notes - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks Director Re - Page 3
operating systems • Support for speed Auto-Negotiate • Ports may accumulate spurious events • Possible switch reset after power failure or power off sequence • SNMP issues Intended audience This document is intended for customers who purchased the Director 2/64 or Director 2/140. Firmware version 07 - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks Director Re - Page 4
Instructions, AA-RSS2D-TE/958-000281-002 • HP StorageWorks Director 2/140 Installation Guide, AA-RTDSD-TE/958000275-003 • McDATA Intrepid Director 6140 Installation and Service Manual, 620-000157-410 • HP StorageWorks Director Element Manager User Guide, AA-RTDUD-TE • HP StorageWorks Director 2/64 - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks Director Re - Page 5
and Service Manual • 620-000134-720-McDATA Enterprise Operating System Command Line Interface User Manual • 620-000131-620-McDATA EOS SNMP Support Manual • 620-000124-500-McDATA Products in a SAN Environment Planning Manual • AA-RMPNT-TE-HP StorageWorks SAN Design Guide • 620-000160-230-McDATA - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks Director Re - Page 6
refer to HP StorageWorks SAN High Availability Planning Guide. • Fabric Elements-Each fabric element is defined by a unique domain ID that ranges between 1 and 31; therefore, the theoretical limit of interconnected directors in a single fabric is 31. The supported limit of interconnected switches in - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks Director Re - Page 7
Director 2/140. Minor Code Enhancements and Fixes in fw 07.01.02-4 This release of firmware version 07.01.02-4 incorporates some minor code enhancements and fixes, and is not a mandatory upgrade, though HP recommends that all directors and edge switches be upgraded to this version of firmware. Firmware - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks Director Re - Page 8
, the Ethernet communications could intermittently hang on director 2/140, edge switch 2/24, and edge switch 2/12. This issue has been corrected. Features not supported in this release The following director and edge switch feature is not supported in this release: • SANtegrity Authentication The - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks Director Re - Page 9
Fabric Switch HP StorageWorks Edge Switch 2/16 Sphereon 3216 Fabric Switch HP StorageWorks Edge Switch 2/24 Sphereon 4500 Fabric Switch HP StorageWorks Edge Switch 2/32 Sphereon 3232 Fabric Switch HP StorageWorks Director 2/64 Intrepid 6064 Director HP StorageWorks Director 2/140 Intrepid - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks Director Re - Page 10
2 lists the minimum version of HAFM that can run with the various versions of firmware for the directors and edge switches. Table 2 HAFM and firmware compatibility Firmware version HAFM version (minimum) 01.01.02 04.00.01 (HP EFCM) 01.02.02-06 04.01.02-14 (SDCM) 01.03.00-35 04.02 - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks Director Re - Page 11
the director or edge switch configuration. Refer to your HP StorageWorks Director Element Manager User Guide Director FC-64 units may receive one of the following messages when they upgrade to firmware 05.02.00-13: • HAFM-Firmware cannot be loaded due to insufficient CTP memory. • EWS-File System Error - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks Director Re - Page 12
sufficient memory. Please contact HP Customer Support if you receive this message. problems caused by processor restart. For example, an application may be configured to poll the director or switch using the Firmware Library option under the Product Manager Maintenance menu. 3. Back up the director confi - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks Director Re - Page 13
switch or director Installation and Service Manual. This publication provides complete procedures for obtaining firmware from the HP web site and downloading firmware to the switch or director using HAFM. • The switch or director Element Manager online help and User Manual. These includes instructions - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks Director Re - Page 14
there are any other switches in the fabric operating with a firmware version earlier than 06.01.00. To prevent this situation, downgrade all Director 2/140s in the fabric to 06.01.00 before downgrading any products in the fabric to 05.xx.xx. This problem only exists with Director 2/140s in the fabric - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks Director Re - Page 15
, refer to the HP StorageWorks HA-Fabric Manager User Guide. The features of this software version are detailed in the accompanying manuals listed in section Other director documentation. Zone FlexPar feature Because zoning is managed on a fabric-wide basis, all switches and directors in the fabric - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks Director Re - Page 16
enabled or disabled through CLI for a specific switch. When upgrading to firmware 07.01.02-4 or installing a new switch with firmware 07.01.02-4 the feature is Support-This provides support for IETF RADIUS (Remote Authentication Dial In User Service) protocol for password authentication. Firmware - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks Director Re - Page 17
switch or director RS-232 service personnel requires log in through the private customer-level access. • Security Log-The Security Log is a new log available in EWS, CLI, and HAFM that records various events concerning the integrity of a switch. This includes authorization or authentication problem - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks Director Re - Page 18
solve the problem, and manually unblock troubleshoot traffic problems within a SAN. The Embedded Port Log is available via EWS, CLI, and HAFM. Embedded Fabric Log The switch-based fabric log records events related to the following services Director 2/64 and the Director 2/140 is disabled by default - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks Director Re - Page 19
directors and edge switches, when you select IP addresses for edge switches, directors and cannot be disabled. All HP-approved host bus adapters (HBAs retrain Storage Area Network (SAN) administrators. Hard zoning and CLI. SNMP changes Firmware 07.01.02-4 supports the following management information - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks Director Re - Page 20
32 Number of unique zone members in HAFM Zoning Library 2048 Number of zones in HAFM Zoning Library 1024 Number of zone sets in HAFM Zoning Library 64 Number of end ports 1024 Number of devices supported (including loop devices) 1024 Using the same firmware All directors and edge switches - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks Director Re - Page 21
SAN running 05.02.00 firmware. A copy of these versions of firmware, are contained on the HP StorageWorks edge switch documentation and firmware CD (Part Number 524-000001-005). Reinstalling feature licenses Feature licenses (or keys) must be reinstalled after performing a factory reset on a director - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks Director Re - Page 22
switch or director problem resolution, the vast majority of problems enhancements include support for managing the . Preferred Path support With firmware elements (directors and switches) that users allows users to save switch configuration settings to figuration settings when switch configuration is - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks Director Re - Page 23
supports the ability to allocate a specific number of buffer credits per port. This feature provides benefit primarily in the Edge Switch 2/12 and 2/24 switches credits only where needed. For the Director 2/64, Director 2/140, and Edge Switch 2/32 switches, this enhancement simply allows more granular - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks Director Re - Page 24
NOTE: This limit is disabled when the switch parameter Suppress Zoning RSCNs on Zone set activations check box is enabled. Known issues This section describes the known issues related to the Director 2/64 and Director 2/140. HSG80 transparent mode not supported with IBM AIX Use of an HSG80 with IBM - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks Director Re - Page 25
for speed Auto-Negotiate Auto-negotiate is supported. However, HP recommends that the port speed for E_Ports (for Interswitch Links, or ISLs) be set to a specific port speed (1Gb/sec or 2Gb/sec, as appropriate for the speed of the directors or edge switches being connected) instead of to Negotiate - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks Director Re - Page 26
Workaround If this condition occurs, the configuration of the edge switch or director must be restored, and the IP address must be restored. Also, all licensed features need to be reactivated by entering the license keys again. SNMP
HP StorageWorks
Director release notes
Part number: AA–RTDV
H
–TE/958–000276–00
8
Eighth edition: (August 2005)