HP StorageWorks 2/140 FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks HA-Fabric M
HP StorageWorks 2/140 - Director Switch Manual
View all HP StorageWorks 2/140 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks 2/140 manual content summary:
- HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks HA-Fabric M - Page 1
HP StorageWorks HA-Fabric Manager release notes Part number: AA-RUR6G-TE/958-000288-011 Ninth edition: (August 2005) - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks HA-Fabric M - Page 2
NT®, and Windows Server® are U.S. registered trademarks of Microsoft Corporation. Hewlett-Packard Company shall not be liable for technical or editorial errors or omissions contained herein. The information is provided "as is" without warranty of any kind and is subject to change without notice - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks HA-Fabric M - Page 3
and available on the following HP web site: http://www.hp.com/country/us/eng/prodserv time may cause loss of management to switches • HAFM installation not correctly cancelled by eld of Properties dialog box of a node device • Error message window may display after you close the HAFM application - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks HA-Fabric M - Page 4
-000324-002 • HP StorageWorks HA-Fabric Manager User Guide, AA-RS2CF-TE • HP StorageWorks HA-Fabric Manager Transition Guide, AA-RV1MB-TE/958- 000384-001 • HP StorageWorks Director and Edge Switch Glossary, AA-RU5JB-TE • HP StorageWorks C-FCSWAPI SDK Bridge Agent Installation Instructions, AA-RVJ1B - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks HA-Fabric M - Page 5
• AA-RV1MB-TE/958-000384-001-HP StorageWorks HA-Fabric Manager Transition Guide • AA-RU5JB-TE-HP StorageWorks Director and Edge Switch Glossary • AA-RVJ1B-TE/958-000405-001-HP StorageWorks C-FCSWAPI SDK Bridge Agent Installation Instructions The HP StorageWorks ha-fabric manager clients CD contains - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks HA-Fabric M - Page 6
also contained on the HP StorageWorks ha-fabric manager documentation error message is displayed stating that the new version must be installed. Follow the instructions requires HAFM Services to be stopped manually. The switches that are not being managed locally are not included in the upgrade. 4 - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks HA-Fabric M - Page 7
08.xx.xx services are started. Be sure to remove 07.02.00 after upgrading to 08.xx.xx. Important information This section describes important information related to the HAFM software, the Edge Switch 2/24, Edge Switch 2/32, Director 2/64, and Director 2/140. Features not supported in this release - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks HA-Fabric M - Page 8
Fabric Switch HP StorageWorks Edge Switch 2/16 Sphereon 3216 Fabric Switch HP StorageWorks Edge Switch 2/24 Sphereon 4500 Fabric Switch HP StorageWorks Edge Switch 2/32 Sphereon 3232 Fabric Switch HP StorageWorks Director 2/64 Intrepid 6064 Director HP StorageWorks Director 2/140 Intrepid - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks HA-Fabric M - Page 9
08.06.00 allows managing of directors and edge switches running any of the versions of firmware listed in Table 2: Table 2 HAFM and firmware compatibility Firmware version HAFM version (minimum) 01.01.02 04.00.01 (HP EFCM) 01.02.02-06 04.01.02-14 (SDCM) 01.03.00-35 04.02.00 - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks HA-Fabric M - Page 10
compatibility with devices in your SAN before upgrading to this firmware version. For more information on upgrading software versions, refer to the HP StorageWorks HA-Fabric Manager User Guide. The features of this software version are detailed in the accompanying manuals listed in section Other HAFM - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks HA-Fabric M - Page 11
performing the operation. Before upgrading firmware, it is highly recommended that you back up the director or edge switch configuration. Refer to your HP StorageWorks director or edge switch Element Manager user guide for more information. Embedded Web Server (EWS) also provides an option to print or - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks HA-Fabric M - Page 12
prone to problems caused by processor restart. For example, an application may be configured to poll the director or switch at regular rmware to 05.02.00-13 on each edge switch using the Send option on the Firmware Library dialog box. Upgrading firmware on a director from 04.xx.xx to 05.xx.xx - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks HA-Fabric M - Page 13
rmware 05.02.00-13 using the Firmware Library option under the Product Manager Maintenance menu. 3. Back up the director configuration using the Backup & back up the director or edge switch configuration. Refer to your HP StorageWorks director or edge switch Element Manager user guide for more - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks HA-Fabric M - Page 14
switch or director Installation and Service Manual. This publication provides complete procedures for obtaining firmware from the HP web site and downloading firmware to the switch or director using HAFM. • The switch or director Element Manager online help and User Manual. These includes instructions - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks HA-Fabric M - Page 15
there are any other switches in the fabric operating with a firmware version earlier than 06.01.00. To prevent this situation, downgrade all Director 2/140s in the fabric to 06.01.00 before downgrading any products in the fabric to 05.xx.xx. This problem only exists with Director 2/140s in the fabric - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks HA-Fabric M - Page 16
fabric-wide basis, all switches and directors in the fabric must switches with the feature enabled. Enhanced SANtegrity Security Suite SANtegrity Security Suite enhanced features include authentication support of connections from the HAFM appliance service processor and SWAPI Direct Connect. This - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks HA-Fabric M - Page 17
Support-This provides support for IETF RADIUS (Remote Authentication Dial In User Service) protocol for password authentication. Firmware which is the switch or director RS-232 connection. Enhanced and identify the source of problems that might jeopardize the switch integrity. • IP Access Control - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks HA-Fabric M - Page 18
an ISL when problems occur that cause a SAN. To , solve the problem, and manually unblock the port troubleshoot traffic problems within a SAN. The Embedded Port Log is available via EWS, CLI, and HAFM. Embedded Fabric Log The switch-based fabric log records events related to the following services - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks HA-Fabric M - Page 19
analyzing fabric and switch behaviors and problems. The Fabric log directors and edge switches, when you select IP addresses for edge switches, directors greater and cannot be disabled. All HP-approved host bus adapters (HBAs) or retrain Storage Area Network (SAN) administrators. Hard zoning controls - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks HA-Fabric M - Page 20
RSCNs on zone set activations check box on the Configure Switch Parameters dialog box. This feature significantly changes the normal behavior be configured through HAFM, EWS, and CLI. SNMP changes Firmware 07.01.02-4 supports the following management information base (MIB) versions on all products: - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks HA-Fabric M - Page 21
32 Number of unique zone members in HAFM Zoning Library 2048 Number of zones in HAFM Zoning Library 1024 Number of zone sets in HAFM Zoning Library 64 Number of end ports 1024 Number of devices supported (including loop devices) 1024 Using the same firmware All directors and edge switches - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks HA-Fabric M - Page 22
SAN running 05.02.00 firmware. A copy of these versions of firmware, are contained on the HP StorageWorks edge switch documentation and firmware CD (Part Number 524-000001-005). Reinstalling feature licenses Feature licenses (or keys) must be reinstalled after performing a factory reset on a director - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks HA-Fabric M - Page 23
the Default Zone to exceed 64 (such as deactivating an active zone set that has more than 64 members), the operation is Directors and edge switches that the HAFM appliance manages • Computers seeking remote client access to the HAFM appliance • SAN management applications such as HP OpenView SAN - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks HA-Fabric M - Page 24
directors and edge switches can be managed via either LAN, the public LAN is the only one that can support manually edit a file on the HAFM appliance to explicitly specify which IP address HAFM should use as the public LAN. For detailed instructions, see HP StorageWorks HA-Fabric Manager User Guide - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks HA-Fabric M - Page 25
Start > Programs > HP StorageWorks ha-fabric manager 8.6 > Start Services. 5. Restart the HAFM application. This procedure works even if you previously set the date/time to an earlier time without using these steps. Rebooting the HAFM appliance will also clear up this problem. Exiting the HAFM - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks HA-Fabric M - Page 26
of a persisted fabric causes two fabrics to be displayed Fabrics are identified by the WWN of the principal switch. If a new principal switch is selected (either manually, or because the current principal switch is removed from the fabric), the fabric is reidentified by the WWN of the new principal - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks HA-Fabric M - Page 27
not to replace the existing policy on the switch ports. User-defined nicknames for node devices the Windows Start menu: Start > Programs > HP StorageWorks ha-fabric manager 8.6 > Call Home Configuration instructions for LAN based Call Home enables this function. There is no need to contact a service - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks HA-Fabric M - Page 28
event may not be sent An Ethernet event may not be sent for a switch that is in a discovered Fabric when the Ethernet cable is disconnected. Domain IDs may generated when a link between switches is disconnected. "Connection offline" and "Connection online" events are not created in the Master Log. 26 - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks HA-Fabric M - Page 29
a full SAN import file. Errors drop down list is not available The Errors drop down supported. However, HP recommends that the port speed for E_Ports (for Interswitch Links, or ISLs) be set to a specific port speed (1Gb/sec or 2Gb/sec, as appropriate for the speed of the directors or edge switches - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks HA-Fabric M - Page 30
impact on the Fibre Channel operations of any edge switch or director. Monitoring switch operations, logging events, and implementing configuration changes allowed. Also, the IP address that is displayed when you select SAN > Server Properties is possibly incorrect. Workaround This is corrected by - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks HA-Fabric M - Page 31
of discovering the switch. New sound HP-UX 11.0 kernel parameters are set too low for most Java applications. Usually you will see this problem as a java.lang.OutOf MemoryError: unable to create new native thread error inconsistent behavior or an error message, restart the client. SAN data is not - HP StorageWorks 2/140 | FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks HA-Fabric M - Page 32
, the Ethernet port on the HAFM appliance can appear to hang. When the Ethernet port encounters problems, the following may occur: • There is an apparent loss of communication to switches being managed by HAFM. • The appliance CPU usage and memory usage display abnormally high readings. Workaround
HP StorageWorks
HA-Fabric Manager release notes
Part number: AA–RUR6G–TE/958–000288–011
Ninth edition: (August 2005)