installation guide hp StorageWorks SAN switch 2/16 Product Version: V3.0.x Second Edition (February 2003) Part Number: AA-RR84B-TE This installation guide provides basic procedures for setting up, configuring, and managing the SAN switch 2/16 and 2/16 Power Pak models. - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 2
is a registered trademark of The Open Group. BROCADE, the Brocade B weave logo, Brocade: the Intelligent Platform for Networking Storage, SilkWorm, and an additional warranty. Printed in the U.S.A. hp StorageWorks SAN Switch 2/16 Installation Guide Second Edition (February 2003) Part Number: AA- - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 3
Support 15 HP Storage Website 15 HP Authorized Reseller 16 1 Overview 17 SAN Switch 2/16 Features 18 Firmware 18 Hardware 19 SFP Media Side 20 Optical Ports 20 ISL Trunking 21 SFPs 21 Power Supply Side 21 Field-Replaceable Units 21 Optional Hardware Kits 22 hp StorageWorks SAN Switch - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 4
Core PID Setting 52 How to Change the Core PID Format 53 Modifying Domain IDs 54 Specifying Custom Status Policies 55 Connecting the Switch to the Fabric 55 Verifying Operation 56 Installing Multiple Switches into an Existing SAN 57 4 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 5
73 4 Backing Up the Configuration and Upgrading Firmware 75 Backing Up System Configuration Settings 76 Restoring the System Configuration Settings 77 Upgrading or Restoring the Switch Firmware 78 Downloading Firmware from the HP Website 79 hp StorageWorks SAN Switch 2/16 Installation Guide 5 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 6
36 7 Sliding the switch into an HP 9000 Series rack 38 8 Installing the mounting brackets 40 9 Installing the tinnerman clips 41 10 Installing the rubber washers 42 11 Assembling the outer rails (HP rack 43 12 Assembling the inner rails 43 6 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 7
5 Rear Panel LED Patterns During Normal Operation 66 6 Physical Specifications 90 7 Power Supply Specifications 91 8 Environmental Requirements 92 9 Cabling Pinouts if Pin 7 is Used 93 hp StorageWorks SAN Switch 2/16 Installation Guide 7 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 8
Contents 8 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 9
porouvitdetshinisforGmautioindtoehelp you set up and configure the HP StorageWorks SAN Switch 2/16. About this Guide About this Guide topics include: ■ Overview, page 10 ■ Conventions, page 11 ■ Rack Stability, page 14 ■ Getting Help, page 15 hp StorageWorks SAN Switch 2/16 Installation Guide 9 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 10
Windows 2000, Windows NT, and IBM AIX ■ Web Tools Graphical User Interface (GUI), for configuring the switch via a supported Web browser Related Documentation For a list of related documents included with this product, see the Related Documents section of the hp StorageWorks SAN Switch 2/16 Version - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 11
names, and text emphasis User input, command and directory names guide. They have the following meanings. WARNING: Text set off in this manner indicates that failure to follow directions in the warning could result in bodily harm or death. hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 12
these symbols indicates the presence of electrical shock hazards. Enclosed area contains no operator serviceable parts. WARNING: To reduce the risk of personal injury from electrical shock hazards , allow the surface to cool before touching. 12 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 13
About this Guide Power supplies or systems marked with these symbols indicate the presence of multiple sources or damage to the equipment, observe local occupational health and safety requirements and guidelines for manually handling material. hp StorageWorks SAN Switch 2/16 Installation Guide 13 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 14
About this Guide Rack Stability Rack stability protects personnel and equipment. WARNING: To reduce the risk of personal safety or damage to the at any time. A rack may become unstable if more than one rack component is extended for any reason. 14 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 15
, specific questions HP Storage Website The HP website has the latest information on this product. Access storage at: http://thenew.hp.com/country/us/eng/prodserv/storage.html. From this website, select the appropriate product or solution. hp StorageWorks SAN Switch 2/16 Installation Guide 15 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 16
HP Authorized Reseller For the name of your nearest HP authorized reseller: ■ In the United States, call 1-800-345-1518 ■ In Canada, call 1-800-263-5868 ■ Elsewhere, see the HP website for locations and telephone numbers: http://www.hp.com. 16 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 17
enabled on your specific switch. Note: This guide refers to both models as the SAN Switch 2/16, unless otherwise noted. This chapter provides the following information: ■ SAN Switch 2/16 Features, page 18 ■ Firmware, page 18 ■ Hardware, page 19 hp StorageWorks SAN Switch 2/16 Installation Guide 17 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 18
fault isolation, automatically disables failing ports and restarts when the problem is resolved. ■ Industry standard Management Information Base (MIB) support. ■ Automatic self-discovery, discovers and registers host server and storage devices. 18 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 19
chassis, and an embedded processor that processes frames up to 1,024 bytes. ■ A real-time clock (RTC) with a 10-year battery and 56 bytes of NVRAM. hp StorageWorks SAN Switch 2/16 Installation Guide 19 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 20
SAN Switch 2/16 to link or cascade to other HP StorageWorks Fibre Channel switches running v2.6x and above, building a highly scalable SAN fabric. The Fibre Channel SAN Switch 2/16 supports FC-PI specification for Fibre Channel SFP transceivers. 20 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 21
The switch must be turned off during replacement of the motherboard. To simplify replacement, the switch has a minimum of internal cables and no jumpers or hardware settings. Replacement instructions are provided with all replacement units ordered. hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 22
Hardware Kits HP provides the following optional hardware kits in support of the SAN Switch 2/16, see Table 2. Table 2: SAN Switch 2/16 Orderable Hardware 221691-B27** C7534A* C7534A* * premerger HP part number ** premerger Compaq part number 22 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 23
Connecting AC Power, page 45 ■ Configuring Network Addressing, page 47 ■ Connecting the Switch to the LAN, page 51 ■ Connecting the Switch to the Fabric, page 55 ■ Installing Multiple Switches into an Existing SAN, page 57 ■ Next Steps, page 58 hp StorageWorks SAN Switch 2/16 Installation Guide 23 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 24
. 2. Unpack the shipping cartons. Note: The Rack Mount Kit shown in Figure 3 may not represent the kit that shipped with your switch. HP reserves the right to substitute Rack Mount Kits, providing applicable instructions with each switch. 24 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 25
Installing the SAN Switch 2/16 2 3 1 5 4 6 Figure 3: Carton contents SHR-2489A hp StorageWorks SAN Switch 2/16 Installation Guide 25 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 26
(6) Pouch containing Rack Mount hardware: • 3-hole Bar Nuts (4) • 10-32 x 3/8" Phillips head screws (10) • 8-32 x 3/16" Phillips head screws (10) • Square alignment washers (8) • Right and left the rail kit that shipped with your switch. 26 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 27
the chassis (the port/cable side). HP cautions that you must install the switch so that air intake and exhaust for all components in the rack flow in the same direction. Caution: Do not block air vents. The switch uses ambient air for cooling. hp StorageWorks SAN Switch 2/16 Installation Guide 27 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 28
them from their containers. ■ Avoid touching pins, leads, or circuitry. ■ Always make sure you are properly grounded when touching a static-sensitive component or assembly. 28 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 29
steps 3 through 5 for the remaining power supply. Note: Do not connect the switch to the network until the IP address is correctly set. For instructions on how to set the IP address, see "Configuring Network Addressing," later in this chapter. hp StorageWorks SAN Switch 2/16 Installation Guide 29 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 30
Switch The Rack Mount Kit supplied with the switch consists of two slide rail assemblies consisting of an inner slide rail attached to an outer slide rail. Read the following sections for complete instructions Inner Slide Rails to the Switch." 30 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 31
the inner slide rail with the end containing the lock release lever towards the port end of the switch. 2. Locate three Phillips head, 8-32 x 3/16" screws provided in the Rack Mount Kit. Secure the inner slide rail to the switch, see Figure 4. hp StorageWorks SAN Switch 2/16 Installation Guide 31 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 32
the port side of the switch slides out the back of the HP 9000 Series Rack. (For example, the switch should face the aisle where exhaust air is released. Air intake and exhaust for all components in the rack should flow in the same direction.) 32 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 33
the switch, see Figure 5. Figure 5: Attaching the rear rack mount brackets SHR-2490A 3. Tighten the screws and torque to 15-inch pounds. 4. Repeat steps 1 through 3 to install the left mount bracket on the left side of the switch, see Figure 5. hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 34
rails in the HP 9000 Series Rack. Obtain the following items, located in the Rack Mount Kit: ■ Four 3-hole bar nuts ■ Eight Phillips head 8-32 x 3/8" screws ■ Eight square alignment washers ■ # 2 Phillips screwdriver with torque capability 34 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 35
the beginning of one U. Note: The SAN Switch 2/16 requires one Unit of rack space. 3. Insert one square alignment washer on each of the eight 10-32 x 3/8" Phillips head screws. Note: The bracket at the end of the outer slide rail, see Figure 6. hp StorageWorks SAN Switch 2/16 Installation Guide 35 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 36
as required. Delete this set of instructions 1 5 1 Phillips head 10-32 x 3/8" screw 2 3-hole bar nut 3 Outer slide rail SHR-2478A 4 L-Brackets 5 Power cord clip (1 of 6) Figure 6: Attaching the outer slide rails to the HP 9000 Series rack 36 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 37
slide rails all the way toward the front or back of the rack. 2. Carefully lift the switch into the rear of the rack, inserting the inner slide rails (attached to the switch) into the outer slide rails (attached to the rack), see Figure 7. hp StorageWorks SAN Switch 2/16 Installation Guide 37 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 38
rack mount bracket to the rack rails. 3. Tighten the screws, and torque to 25-inch pounds. 4. See the "Connecting AC Power" on page 45, for instructions on applying power to the switch. 38 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 39
brackets ■ Rail mounting hardware, shown next: (6) #8-32 x 5/16 Phillips pan-head screw with captive star lock washers (6) #8 Flat washers (6) M5 Torx head screw with captive lock washers (2) Rubber washers (4) M5 U-type Tinnerman clips hp StorageWorks SAN Switch 2/16 Installation Guide 39 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 40
hardware is available. 2. Choose a mounting location in the rack for the switch. 3. Install each of the two mounting brackets with one M5 Torx head screw with captive lock washers as shown in Figure 8. Figure 8: Installing the mounting brackets 40 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 41
Installing the SAN Switch 2/16 4. Install two M5 U-type Tinnerman clips for each of the front columns of the rack in the top and slotted portion of the outer rail flush against the rear rail-tray brackets. Install them as shown in Figure 10. hp StorageWorks SAN Switch 2/16 Installation Guide 41 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 42
illustration as required. [8] Adjust the size of the outer graphic frame as required. Delete this set of instructions 1 2 1 Rubber washer (1 of 2) 2 Rear rail tray bracket (1 of 2) Figure 10: left and the lower right screws until later. 42 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 43
Figure 11: Assembling the outer rails (HP rack) 7. Assemble the two inner rails (one on each side) to the switch using (6) #8-32 x 5/16 Phillips pan-head screws, and #8 flat washer as shown in Figure 12. Figure 12: Assembling the inner rails hp StorageWorks SAN Switch 2/16 Installation Guide 43 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 44
9. Install the two remaining M5 Torx screws to complete the installation. See Figure 13. Figure 13: Installing switch into the HP rack SHR-2583 10. See the next section, "Connecting AC Power" for instructions on applying power to the switch. 44 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 45
the rails. However, the tabs on the clips can be on either side of the rail, provided all the tabs are on the same side. hp StorageWorks SAN Switch 2/16 Installation Guide 45 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 46
state, (and this is not due to the switch being set to beacon), see "Interpreting LED Activity" on page 62 in Chapter 3. Note: For more information about beaconing, refer to the hp StorageWorks fabric os version 3.0x/V4.0x procedures guide. 46 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 47
communication software (for example, ProComm Plus or HyperTerminal) ■ Ethernet cable for connecting the switch to the workstation or to a network containing the workstation ■ SFPs and cables, as required to connect the switch to the fabric hp StorageWorks SAN Switch 2/16 Installation Guide 47 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 48
the switch power is on and POST is completed. See the "Power-On Self Test" section, earlier in this chapter. 5. Power on the workstation and establish a connection to the switch using a terminal emulator application (such as Hyperterminal). 48 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 49
Installing the SAN Switch 2/16 Note: These steps show instructions specific to onto the switch (with administrative privileges). The default administrative logon is admin and the default password is password. a. Enter ]: Enter "y" to set now. hp StorageWorks SAN Switch 2/16 Installation Guide 49 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 50
only for use during the initial setting of the IP address and for service purposes. Using the Serial port during normal switch operation or for regular maintenance is not recommended. 8. Record the IP address on the label affixed to the switch. 50 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 51
. Verify that the switch is not accessed from any other connections during the remaining steps. 4. Log on to the switch with administrative privileges by telnet. The default administrative logon is admin and the default password is password. hp StorageWorks SAN Switch 2/16 Installation Guide 51 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 52
that the edge switch's (SAN Switch 2/16 in this case) Core PID format matches the Core switch's PID format, before connecting to the SAN. For example, switches with firmware V3.0.2f or later have the PID set to 1. For a SAN to work correctly, all HP StorageWorks SAN switches or HP Surestore FC - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 53
2. Disable the switch type, SwitchDisable. 3. To reset the PID format, use the "configure" telnet command. Type configure. The following displays, Configure... 4. Type y at the Fabric parameters prompt, Fabric parameters (yes, y, no, n): [no] y hp StorageWorks SAN Switch 2/16 Installation Guide 53 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 54
4. Enter a unique domain ID (such as the domain ID used by the previous switch, if still available). Domain: (1..239) [1] 3 5. Complete the remaining prompts (or press CTRL+D to accept the remaining settings without completing all the prompts). 54 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 55
target before connecting to the device. The default port configuration is fabric, not private loop. The switch does not auto-sense topology. Connecting the Switch to the Fabric Use these steps to not slide in easily, check the orientation. hp StorageWorks SAN Switch 2/16 Installation Guide 55 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 56
to verify that the switch is running properly. 1. Access your browser. 2. At the URL address window, type http://your switch IP address. 3. If connected properly, the name of your switch appears (in green) at the prompt, indicating Healthy/OK. 56 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 57
the package contents, between a host computer and the Serial port of the switch. See the "Setting Network Addresses via a Serial Connection," earlier in this chapter, to make a Serial connection through a workstation and to set the IP address. hp StorageWorks SAN Switch 2/16 Installation Guide 57 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 58
set the speed level for all ports in a switch. Use the portCfgSpeed to set the speed level for a single port. Depending on your environment you may need to force a port to use a specific speed level. Auto negotiation may not be supported by the 58 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 59
the SAN Switch 2/16 device. Check the configuration information for your network components for specific requirements. See the hp StorageWorks fabric os version 3.0.x/4.0.x procedures user guide, for a detailed command description. Cascading Switches The Domain ID number uniquely identifies a switch - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 60
Installing the SAN Switch 2/16 60 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 61
Managing the SAN Switch 2/16 3 This chapter covers the following topics: ■ Interpreting LED Activity, page 62 ■ Management Overview, page 68 ■ Running Basic Switch Operations Using Telnet, page 69 ■ Diagnostic Tests, page 73 hp StorageWorks SAN Switch 2/16 Installation Guide 61 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 62
LEDs: ■ One Switch Power LED on the front panel ■ One Port Status LED above and to the left of each of the 16 ports ■ One Port Speed LED above and to the left of each of the 16 port Table 4 describes front panel LEDs, and their functionality. 62 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 63
Managing the SAN Switch 2/16 Table 4: Front Panel LED Patterns During Normal Operation LED Port Status LED LED port. No action required. No action required. No action required. No action required. Reset the switch from a management station. hp StorageWorks SAN Switch 2/16 Installation Guide 63 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 64
. The port is transmitting/receiving at 1 Gbps. The port is transmitting/receiving at 2 Gbps. Recommended Action Reset the switch from a management station. Reset the port from a management station. No action required. No action required. 64 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 65
the switch supplier. No action required. Slow-flashing green Diagnostic failure on one or more ports. Errors may be listed in the error log. Refer to the hp StorageWorks fabric OS version 3.0.x/4.0.x procedures guide for more information. hp StorageWorks SAN Switch 2/16 Installation Guide 65 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 66
failed. Recommended Action Verify power supply is on and power cable is connected to a valid power source. No action required. Verify that the switch is on and boot had time to complete. If there is still no light, contact the switch supplier. 66 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 67
LEDs for fault indicators. Slow-flashing yellow Diagnostic failure on one or more ports. Errors may be listed in the error log. Refer to the hp StorageWorks fabric os version 3.0.x/4.0.x procedures guide for more information. hp StorageWorks SAN Switch 2/16 Installation Guide 67 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 68
of being "virtually" in front of any fabric, switch, or port. For more information refer to the hp StorageWorks web tools version 3.0.x/V4.0.x user guide. Optional Management Features Refer to the hp StorageWorks SAN Switch 2/16 Version 3.0.2k Release Notes for a complete list of management - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 69
the user exists. 3. Enter the password for the user: password: xxxxxx The default password is password. 4. If the login was successful, a prompt is displayed showing the switch name and user ID you are logged in as. For example: switch55>admin: hp StorageWorks SAN Switch 2/16 Installation Guide 69 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 70
a prompt and leave the parameter value as is. 3. At the Ethernet IP Address prompt, enter the new IP address for the Ethernet port on the switch. Press the Enter to continue. 70 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 71
Time All switches maintain current date and time in non-volatile memory. Date and time are used for logging events. Switch operation does not depend on the date and time; a switch with an incorrect date and time value still functions properly. hp StorageWorks SAN Switch 2/16 Installation Guide 71 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 72
Configuration Settings Use these steps to display the system configuration settings. 1. Log into the switch as the admin user. 2. At the command line enter the following command: configShow The system configuration settings are displayed. 72 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 73
about error messages, refer to the hp StorageWorks fabric os procedures version 3.0.x/4.0.x user guide. Diagnostic Tests Diagnostic tests are provided to help troubleshoot the hardware and the firmware. The diagnostic tests provided on the switch include tests of internal connections and circuitry - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 74
Managing the SAN Switch 2/16 74 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 75
the Configuration and Upgrading Firmware 4 This chapter covers the following topics: ■ Backing Up System Configuration Settings, page 76 ■ Upgrading or Restoring the Switch Firmware, page 78 ■ Downloading Firmware from the HP Website, page 79 hp StorageWorks SAN Switch 2/16 Installation Guide 75 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 76
prompt you for each parameter, as follows: Example: switch:admin> configupload Server Name or IP Address [host]: 123.45.678.901 User Name [user]: kelev File Name [config.txt]: switch1 Protocol (RSHD or FTP) [rshd]: ftp Password: upload complete 76 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 77
location and filename of the system configuration file, and password is the password for the user ID specified. Note: The password operand is only required if you are using FTP. 5. Reboot the switch by entering the following command: fastBoot hp StorageWorks SAN Switch 2/16 Installation Guide 77 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 78
the path location and filename of the new firmware file, and password is the password for the user ID specified. Note: The password operand is only required if you are using FTP. 4. Reboot the switch by entering the following command: fastBoot 78 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 79
and Upgrading Firmware Downloading Firmware from the HP Website To download the firmware from the HP website, go to http://www.hp.com/support. The website contains the required loaders and instructions for downloading the firmware to a switch. hp StorageWorks SAN Switch 2/16 Installation Guide 79 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 80
Backing Up the Configuration and Upgrading Firmware 80 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 81
energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment which case the FCC could void the user's authority to operate the equipment. hp StorageWorks SAN Switch 2/16 Installation Guide 81 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 82
product. In a domestic environment this product may cause radio interference, in which case the user may be required to take adequate measures. Spécification ATI Classe A (France) DECLARATION D' 7779:1999 (Typprüfung) VCCI EMC Statement (Japan) 82 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 83
Harmonics Conformance (Japan) BSMI EMC Statement (Taiwan) Regulatory Compliance Notices RRL EMC Statement (Korea) hp StorageWorks SAN Switch 2/16 Installation Guide 83 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 84
as a Class 1 Laser product, conforming to the requirements contained in Department Of Health and Human Services (DHHS) regulation 21 CFR, Subchapter J. The certification is indicated by a label on the metal established by the IEC and U.S. DHHS. 84 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 85
or proper disposal, contact your HP authorized reseller or your authorized service provider. WARNING: Your switch contains an internal lithium manganese dioxide system or return them to HP, your authorized HP partners, or their agents. hp StorageWorks SAN Switch 2/16 Installation Guide 85 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 86
Regulatory Compliance Notices 86 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 87
removing them from their containers. ■ Avoid touching pins, leads, or circuitry. ■ Always make sure you are properly grounded when touching a static-sensitive component or assembly. hp StorageWorks SAN Switch 2/16 Installation Guide 87 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 88
conductive field service tools. ■ Use a portable field service kit with HP authorized reseller install the part. Note: For more information on static electricity, or for assistance with product installation, contact your HP authorized reseller. 88 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 89
Technical Specifications This appendix covers the following topics: ■ Dimensions, page 90 ■ Power Supply Specifications, page 91 ■ Environmental Requirements, page 92 ■ Memory Specifications, page 93 C hp StorageWorks SAN Switch 2/16 Installation Guide 89 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 90
2/16 dimensions. Table 6: Physical Specifications Height Dimension Depth Width Weight (with both power supplies) Value 1.72 +/- 0.01 inches (4.37 +/- 0.03 cm) 24.5 +/- 0.03 inches (62.2 +/- 0.1cm) 17 inches (43.2 cm) 28.0 lbs (12.7 kg) 90 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 91
power supply is universal and capable of functioning worldwide without using voltage jumpers or switches. It meets IEC 61000-4-5 surge voltage requirements. The power supply has its 300 usec - hot/cold start Fused in both hot & neutral lines . hp StorageWorks SAN Switch 2/16 Installation Guide 91 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 92
environmental ranges that are acceptable when the switch is operating, and the acceptable ranges when the switch is not operating. .Table 8: Environmental Requirements sq.wave 5G, 0-3 kHz at 1.0 octave/minute 10G, 0-5kHz at 1.0 octave/minute 92 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 93
in Table 9. .Table 9: Cabling Pinouts if Pin 7 is Used PIN 1 2 3 4 5 6 7 8 9 Signal Description TxData RxData Transmit Data Receive Data GND Logic Ground CTS Clear to Send hp StorageWorks SAN Switch 2/16 Installation Guide 93 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 94
Technical Specifications 94 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 95
interface with a set of services. Arbitrated Loop A shared 100 MBps or 200 MBps Fibre Channel transport structured as a loop. Can support up to 126 devices and one an arbitrating L_Port waits for a response before beginning loop initialization. hp StorageWorks SAN Switch 2/16 Installation Guide 95 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 96
is seven. See also Fabric, ISL. Chassis The metal frame in which the switch and switch components are mounted. Circuit An established communication path between two ports. Consists of two as through telnet or SNMP, and does not involve a GUI. 96 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 97
; the number of receive buffers allocated by a recipient port to an originating port. Used by Class 1 and 2 services to manage the exchange of frames across the fabric between source and destination. See also End-to-end Flow Control, BB_Credit. hp StorageWorks SAN Switch 2/16 Installation Guide 97 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 98
Protocol; mapping of protocols onto the Fibre Channel standard protocols. For example, SCSI FCP maps SCSI-3 onto Fibre Channel. Fibre Channel Transport A protocol service that supports communication between Fibre Channel service providers. 98 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 99
Channel. Set the gateway address on one switch to the Fibre Channel IP address of another switch to enable the other switch to forward IP traffic to the Ethernet port on the second switch. Gbps Gigabits per second (1,062,500,000 bits/second). hp StorageWorks SAN Switch 2/16 Installation Guide 99 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 100
to transmit a frame, from the time it is sent until it arrives. Link Services A protocol for link-related actions. Link As applies to Fibre Channel, a physical connection between two ports, consisting of both transmit and receive fibers. 100 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 101
Initialization Primitive; the signal used to begin initialization in a loop. Indicates either loop failure or resetting of a node. Looplet A set of devices connected in a loop to a port that the open originator, and then enters the Open state. hp StorageWorks SAN Switch 2/16 Installation Guide 101 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 102
Power On Self-Test; a series of tests run by a switch after it is turned on. Private Device A device that supports arbitrated loop protocol and can interpret 8-bit addresses, but cannot can communicate with either private or public NL_Ports. 102 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 103
can log into the fabric and support 20-bit addresses (or has 20-bit phantom addresses created for it by the switch). Public Loop An arbitrated loop direction between two N_Ports. Service Rate The rate at which an entity can service requests. hp StorageWorks SAN Switch 2/16 Installation Guide 103 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 104
be accessed by an L_Port in the Open state. Translative Mode A mode in which private devices can communicate with public devices across the fabric. 104 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 105
when it is not connected or has not yet assumed a specific function in the fabric. UDP User Datagram Protocol; a protocol that runs on top of IP and provides port multiplexing for upper-level XMITTED CLOSE state cannot attempt to arbitrate. hp StorageWorks SAN Switch 2/16 Installation Guide 105 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 106
partitioning of the fabric into logical groupings of devices. Devices in a zone can only access and be accessed by devices in the same zone. 106 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 107
25 carton contents checklist 26 cascading switches 59 changing switch password 70 changing the admin password 70 changing the admin user ID 70 checking results 47 command line address 58 domain ID 59 configuring 54 default 54 domain IDs 54 hp StorageWorks SAN Switch 2/16 Installation Guide 107 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 108
57 N network addressing 47 NVRAM 19 O optical ports LEDs 62 outer slide rails 34 P physical dimensions of switch 90 port ethernet port 19 LED for port speed 62 LED for port status 62 serial port 19 speed 20 positioning the switch inside the rack 38 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 109
support, HP 15 telnet 70 managing by 68 temperature, requirements 92 tests, diagnostic 74 text symbols 11 thermometers 19 three hole bar nuts 34 tips for installing 30 U upgrading or restoring the switch firmware 78 V verifying operation 56 voltage capability 28 hp StorageWorks SAN Switch 2/16 - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 110
Index W warning rack stability 14 symbols on equipment 12 web tools 68 websites HP storage 15 weight, switch 90 Z zoning summary 18 110 hp StorageWorks SAN Switch 2/16 Installation Guide - HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 111
- HP StorageWorks 2/16 | SAN switch 2/16 version 3.0.x installation guide - Page 112
installation
guide
hp
StorageWorks
SAN switch 2/16
Product Version:
V3.0.x
Second Edition (February 2003)
Part Number:
AA-RR84B-TE
This installation guide provides basic procedures for setting up, configuring, and managing the
SAN switch 2/16 and 2/16 Power Pak models.