HP StorageWorks 2/16V Brocade Fabric OS Command Reference Manual - Supporting
HP StorageWorks 2/16V - SAN Switch Manual
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks 2/16V manual content summary:
- HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 1
53-1000436-01 15 Jun 2007 Fabric OS Command Reference Manual Supporting Fabric OS v5.3.0 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 2
http:// www.brocade.com/support/oscd. Export of technical data contained in this document may require an export license from the United States government. Brocade Communications Systems, Incorporated Corporate Headquarters Brocade Communications Systems, Inc. 1745 Technology Drive San Jose, CA - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 3
-09 Manual September 1999 May 2000 December 2000 July 2001 December 2001 March 2002 September 2002 April 2003 April 2003 May 2003 July 2003 August 2003 October 2003 Excluding edits and commands updated to support the SilkWorm 3250, 3850, and 24000 switches, added 3 commands, changed 20 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 4
Manual Fabric OS Command Reference Manual Fabric OS Command Reference Manual 53-0000519-12 53-1000240-01 Fabric OS Command Reference 53-1000436-01 Manual Chapter 2, "Fabric OS Commands," content to Structured FrameMaker format to support XML delivery of command content (due to this process and a - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 5
About This Document How This Document Is Organized xv Supported Hardware and Software xvi What's New in This Document 2 Fabric OS Commands aaaConfig 3 ad 6 ag 16 agshow 21 agtCfgDefault 23 agtCfgSet 26 agtCfgShow 29 aliAdd 32 aliCreate 33 aliDelete 34 aliRemove 35 aliShow 36 aptPolicy - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 6
54 burninLevel 55 burninStatus 56 camTest 57 centralMemoryTest 59 cfgActvShow 63 cfgAdd 64 cfgClear 65 cfgCreate 66 cfgDelete 67 cfgDisable 68 cfgEnable 69 cfgRemove 70 cfgSave 97 configure 100 crossPortTest 107 dataTypeShow 110 ii Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 7
diagEnv 122 diagFailLimit 124 diagHelp 125 diagLoopId 126 diagModeShow 127 diagPost 128 diagRetry 129 diagSetBurnin 130 diagSetCycle 131 diagShow 132 diagShowTime 133 148 errModuleShow 149 errShow 150 exit 151 fabPortShow 152 Fabric OS Command Reference Manual iii 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 8
fcpProbeShow 191 fcpRlsShow 192 fcrbcastconfig 193 fcrChipTest 194 fcrConfigure 196 fcrDisable 197 fcrEnable 198 fcrFabricShow 199 fcrLsanCount 200 fcrLsanMatrix 201 iv Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 9
253 fwAlarmsFilterShow 254 fwClassInit 255 fwConfigReload 256 fwConfigure 257 fwFruCfg 261 fwHelp 262 fwMailCfg 263 fwPortDetailShow 265 fwSamShow 268 fwSet 269 Fabric OS Command Reference Manual v 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 10
iscsiCfg 311 iscsiChipTest 319 iscsiHelp 320 iscsiPathTest 322 iscsiPortCfg 323 iscsiSessionCfg 326 iscsiswcfg 328 iscsiTargetName 330 islShow 331 isnscCfg 332 vi Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 11
372 myId 373 nbrStateShow 374 nbrStatsClear 375 nodeFind 377 nsAliasShow 379 nsAllShow 382 nscamShow 383 nsShow 385 nsZoneMember 388 passwd 391 Fabric OS Command Reference Manual vii 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 12
pkiRemove 439 pkiShow 440 policy 441 portAlpaShow 444 portBufferShow 445 portCamShow 447 portCfg 449 portCfgDefault 455 portCfgEPort 456 portCfgEXPort 457 viii Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 13
499 portLogPdisc 500 portLogReset 501 portLogResize 502 portLogShow 503 portLogShowPort 508 portLogTypeDisable 509 portLogTypeEnable 510 portLoopbackTest 511 portMirror 514 portName 517 Fabric OS Command Reference Manual ix 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 14
563 secHelp 565 secModeDisable 566 secModeEnable 567 secModeShow 572 secNonFCSPasswd 573 secPolicyAbort 574 secPolicyActivate 575 secPolicyAdd 576 secPolicyCreate 579 secPolicyDelete 582 x Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 15
620 slotShow 621 slTest 623 snmpConfig 625 snmpMibCapSet 631 snmpMibCapShow 633 spinFab 635 spinJitter 638 spinSilk 641 sramRetentionTest 645 statsClear 647 Fabric OS Command Reference Manual xi 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 16
syslogdIpRemove 691 syslogdIpShow 692 sysShutdown 693 systemVerification 695 tempShow 697 timeout 698 topologyShow 699 traceDump 701 trackChangesHelp 702 trackChangesSet 703 xii Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 17
Advanced Performance Monitoring Commands 746 Secure Fabric OS Commands 747 Exclusive Primary FCS Commands Commands Exclusive to the Primary FCS 749 Fabric OS Command Reference Manual xiii 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 18
Control Processor Commands Commands Supported on the Standby CP 753 Chapter 6 supportShow Reference supportShow Control Commands 755 supportShow Command Groups 756 Proc Entry Information Displayed 758 Appendix A RBAC Command Availability xiv Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 19
manual written to help system administrators and technicians operate, maintain, and troubleshoot SAN products. "About This Document" contains the following sections: • "How This Document Is Organized," next • "Supported Brocade SAN and Brocade Brocade switches Brocade 24000 and Brocade 48000 directors - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 20
• Brocade 5000 switch • Brocade 7500 switch • Brocade 7600 switch • Brocade 24000 director • Brocade 48000 director In those instances in which procedures or parts of procedures documented here apply to some switches but not to others, this guide identifies exactly which switches are supported and - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 21
What's New in This Document • New commands that were added since this document was last released: - ipfilter - iscsiswcfg - fastwritecfg - fcrLsanCount - fcrLsanMatrix Fabric OS Command Reference Manual xvii 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 22
- firmwareDownloadStatus - firmwareRestore - firmwareShow - fwPortDetailShow - ipAddrSet - ipAddrShow - isnscCfg - licensePort - lsanZoneShow - iscsiCfg - iscsiswcfg - myId - passwd - passwdCfg - perfAddIPMonitor - perfAddRWMonitor xviii Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 23
- tsClockServer - userConfig NOTE: FOS v5.3.0. supports the TCP/IP netstat command. Use this command to show network status, print information on active sockets, routing tables, interfaces, masquerade connections, or multicast memberships. By default, netstat lists open sockets. For a list - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 24
• Information that was deleted or deprecated since this document was last released: - savecore - traceftp - iscsitargetname - fcrdisable - fcrenable - crossporttest xx Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 25
narrative portions of this guide are presented in mixed you to potential damage to hardware, firmware, software, or data. WARNING: A SAN-specific terms, visit the Storage Networking Industry Association online dictionary at http://www.snia.org/education/dictionary. Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 26
CD-ROM and on the Brocade Web site, through Brocade Connect. NOTE Go to http://www.brocade.com and click Brocade Connect to register at no cost for a user ID and password. Fabric OS • Fabric OS Administrator's Guide • Fabric OS Command Reference Manual • Fabric OS MIB Reference • Fabric - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 27
Installation Procedure Brocade 7600 • Brocade 7600 Hardware Reference Manual • Brocade 7600 QuickStart Guide Brocade 7500 • Brocade 7500 Hardware Reference Manual • Brocade 7500 QuickStart Guide • Brocade 7500 Fan Assembly Replacement Procedure • Brocade Mid Sized Power Supply Replacement Procedure - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 28
Manual (for v4.x software) • Brocade 3250/3850 QuickStart Guide (for v4.x software) Brocade 200E • Brocade 200E Hardware Reference Manual (for v5.x software) For practical discussions about SAN design, implementation, and maintenance, you can obtain Building SANs with Brocade Fabric Switches - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 29
on entering the tunnel, and then reconstructing them as they leave the tunnel. Fabric OS supports eight FCIP interswitch links between two Brocade switches (Brocade 7500 or Brocade 48000 with a FR4-18i blade) or routes. All 16 links can be used as FCIP links with the remaining links going to other - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 30
Information - Technical Support contract number, if applicable - Switch model - Switch operating system version - Error numbers and messages received - supportSave command output - Detailed description of the problem and specific questions - Description of any troubleshooting steps already performed - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 31
Feedback Because quality is our first concern at Brocade, we have made every effort to ensure the topic needs further development, we want to hear from you. Forward your feedback to: [email protected] Provide the title and version number and as much detail as possible about your issue, - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 32
xxviii Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 33
SAN and Brocade switches and directors using the Fabric OS command line interface (CLI). The following information is discussed: • "Understanding Role-Based Access Control" on page 1 • "Using the Command Line Interface" on page 2 Refer to Fabric OS Administrator's Guide for information regarding - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 34
tasks involved in managing a Brocade switch or director • Configuration and management of the Brocade fabric on multiple levels • Identification, isolation, and management of SAN events across every switch in the fabric • Management switch licenses The remainder of this guide describes each command - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 35
. It is effective for the next AAA request. The configuration applies to all switch instances in a platform supporting multiple switch domains. Customers can use centralized RADIUS servers to manage AAA services for a switch, as defined in RFC 2865. When server is a required operand, it must be - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 36
the specified RADIUS server is used. --localonly Enables the switch-local database for AAA services. Use this to select the switch-local database as the primary AAA service. --radiusonly Enables the current RADIUS configuration for AAA services. Use this to select the RADIUS configuration as the - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 37
aaaConfig 2 Primary AAA Service: Switch database Secondary AAA Service: None To change the configuration for server 192.168.233.48: switch:admin> aaaconfig --change 192.168.233.48 -p 3002 -s newsecret -t 1 See Also none Fabric OS Command Reference Manual 5 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 38
Admin Domains, the default zone mode should be set to "No Access" mode. Refer to defZone for more information. To set the default zone mode to "No Access": switch:admin> ad --select AD0 switch:admin> defzone --noaccess switch:admin> cfgsave 6 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 39
Admin Domain can be specified as a number. Valid values include 0 through 255. AD0 and AD255 are always Benefits include: • Grants port control and zoning on the switch port and the devices attached to that port. • Supports node or port WWNs. Fabric OS Command Reference Manual 7 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 40
rights to zone the devices. Provides administrative view rights to the switch port the device is connected to: for example, portShow, nsShow an activated state. AD0 is always in an activated state. By default, after the Admin Domain is enabled, the devices specified in the Admin Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 41
--create ad_id -d "dev_list"-s "switch_list" Creates a new administrative domain with the specified device and switch list. Newly created Admin Domains are in an activated state. On initial creation, the ADs contain ad --apply or ad --save. Fabric OS Command Reference Manual 9 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 42
members do not exist in the fabric. The output is similar to ad --show; however, all members that are from non-Admin Domain aware switches and members that are not online are marked with a B or an asterisk B at the end, respectively. 10 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 43
switch WWNs specified in AD's switch support Exchange Service Support (ESS), and therefore the Name Server cannot get the correct port range of such switches Examples To enable AD5: switch:admin> ad --activate 5 ): switch admin> ad --create "AD1", -d "100,5; 1,3; 20:00:00:e0:8b:05:4d:05" switch admin - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 44
:80:59:13" To create an Admin Domain with both device and switch list: switch:admin> ad --create "AD1", -d "100,5; 1,3; 21:20:00:00:e0:8b:05:4d:05" -s "100; 10:00:00:60:69:80:59:13" To deactivate Admin Domain 5: switch:admin> ad --deactivate 5 You are about to deactivate an AD. This - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 45
> ad --show 10 -m 1 Current AD: 255 : AD255 Defined configuration AD: 1 : AD1 Active Device WWN members: Switch port members: 21:00:00:80:e5:12:8b:37; 21:00:00:80:e5:12:8b:55; 1,0; 1,1; 1,2; 1,3; 1,4; 1,5; 1,6; 1,7; 1,8; 1,9; 1,10; 1,11; Fabric OS Command Reference Manual 13 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 46
1,3; 1,4; 1,5; 2,0**; 2,1**; 2,2**; 2,3**; 2,4**; 2,5**; Switch port members: Member is AD Unaware ** - Member does not exist 5,0*; 5,1*; 5,2*; 5,3*; 5,4*; 5,5*; 1,6; 1,7; 1,8; 1,9; 1,10; To abort the Admin Domain management transaction buffer: Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 47
AD transaction (yes, y, no, n): [no] y See Also To display the current Admin Domain transaction: switch:admin> ad --transshow Current transaction token is 26816 It is abortable switch:admin> ad --transshow There is no outstanding zoning transaction cfgSave, cfgTransShow, defZone, logout Fabric OS - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 48
Note: After AG mode is disabled, the switch will come online with default zone access set to "No Access". In order to merge the switch to a fabric you must set the default zone to "All Access" and disable/enable the E_Port". --mapshow [N_Port] 16 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 49
were mapped to the recovered N_Port experience failback. The remaining F_Ports are not redistributed among the online N_Ports during the failback. Fabric OS Command Reference Manual 17 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 50
: switch NodeName : 10:00:00:05:1e:04:06:bb Number of Ports : 24 IP Address(es) : 10.32.173.66, fec0:60:69bc:66:205:1eff:fe36:1199 Firmware Version : v5.3.0_rel_bld46 N_Ports : 2 F_Ports : 2 Attached N_Port information: Port PortID PortWWN FO FB IP_Addr F_Ports 17 0x023d00 20:3d - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 51
17 0 18 1 19 1 20 1 23 1 switch:admin> ag --failoverenable 17 Failover policy is enabled for port 17 switch:admin> ag --failoverdisable 17 Failover policy is disabled for port 17 switch:admin> ag --failovershow 17 Failover on N_Port 17 is not supported switch:admin> ag --failbackdisable - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 52
2 ag See Also admin> ag --failbackshow 17 Failback on N_Port 17 is not supported switch:admin> ag --failbackenable 17 Failback policy is enabled for port 17 portCfgNPort, portCfgNPIVPort 20 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 53
Access Gateway information registered with the fabric. switch:admin> agshow --name switch Name : WT_Stealth NodeName : 10:00:00:05:1e:34:e4:bd N-Port ID(s) : 0x010200 Number of Ports : 16 IP Address(es) : 10.202.90.231 Firmware Version : v1.0.0 N-Ports : 1 F-Ports : 2 Attached F-Port - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 54
the fabric: switch:admin> agshow See Also Worldwide Name Ports Enet IP Addr Firmware Local/Remote 10:00:00:00:c9:3f:7c:86 16 10.202.90.231 v1.0.0 local 10:00:00:00:c8:3f:7c:b9 17 10.202.90.232 v1.0.0 remote portCfgNPIVPort 22 Fabric OS Command Reference Manual 53-1000436 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 55
are persistent across power cycles and reboots. For dual-domain systems, agtCfgDefault operates on the SNMP agent associated with the current switch. This command resets the following values: sysDescr The system (switch) description. The default value is "Fibre Channel Switch" on most platforms - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 56
by comparing nonzero IP octets. For example, an ACL of 192.168.64.0 enables access by any hosts that start with the specified octets. The switch only and will propagate across the fabric. Operands none Examples To reset the SNMP agent to default values: switch: Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 57
configuration: Entry 0: Access host subnet area 192.168.64.0 (rw)] Entry 1: No access host configured yet default Current SNMP Agent Configuration Customizable MIB-II system variables: sysDescr = Fibre Channel Switch. sysLocation = End User Premise sysContact = Field Support Manual 25 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 58
. These values are persistent across power cycles and reboots. For dual-domain systems, this command operates on the SNMP agent associated with the current switch. This command updates the following values: sysDescr The system (switch) description. The default value is "Fibre Channel Switch" on - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 59
value, o to skip the rest of configuration, or o to cancel any change. To correct any input mistake: erases the previous character, erases the whole line, sysDescr: [Fibre Channel Switch.] sysLocation: [End User Premise.] sysContact: [Field Support - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 60
's IP address: [1080::8:800:200C:1230] 10.32.147.113 Community (rw): [private] Trap Recipient's :1234/64 Read/Write? (true, t, false, f): [true] Access host subnet area: [1080::8:800:200C:1234] 10.32.147. , SW_v5_x.mib, "Switch Management Information & Switch Enterprise Specific Trap", RFC1157 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 61
The system (switch) description. The default value is "Fibre Channel Switch". sysLocation The location of the system. The default value is "End User Premise". sysContact The contact information for the system. The default value is "Field Support". Refer to the Fabric OS MIB Reference Manual for - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 62
0.0.0.0. The default values of all Switch. sysLocation = End User Premise. sysContact = Field Support. authTraps = 0 (OFF) SNMPv1 community and trap recipient configuration: Community 1: Secret C0de (rw) Trap recipient: 10.32 32.147.255 (rw) 30 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 63
Entry 3: Entry 4: Entry 5: Access host subnet area 1080::8:800:200C:123/64 (rw) No access host configured yet No access host configured yet No access yet agtCfgDefault, agtCfgShow snmpConfig, SW_v5_x.mib, "Switch Management Information & Switch Enterprise Specific Trap", RFC1157, "A Simple Network - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 64
To add members to zone aliases array1, array2, and loop1: switch:admin> aliadd "array1", "1,2" switch:admin> aliadd "array2", "21:00:00:20:37:0c:72:51" switch:admin> aliadd "loop1", "4,5[0x02]; 6,7[0xEF]" See Also aliDelete, aliRemove, aliShow 32 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 65
To create a zone alias: switch:admin> alicreate "array1", "2,32; 2,33; 2,34" switch:admin> alicreate "array2", "21:00:00:20:37:0c:66:23" switch:admin> alicreate "loop1", "4,5[0x02]; 6,7[0xEF]; 5,4" See Also aliAdd, aliDelete, aliRemove, aliShow Fabric OS Command Reference Manual 33 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 66
. For the change to be preserved across switch reboots, it must be saved to nonvolatile Brocade Advanced Zoning license. When secure mode is enabled, this command can be issued only from the primary FCS switch zone alias array2: switch:admin> alidelete "array2" See Also aliAdd, aliCreate, - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 67
. Examples Remove a World Wide Name from "array1": switch:admin> aliremove "array1", "3,5" switch:admin> aliremove "array1", "21:00:00:20:37:0c:76:8c" switch:admin> aliremove "array1", "0xEF" See Also aliAdd, aliCreate, aliDelete, aliShow Fabric OS Command Reference Manual 35 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 68
value is 0. If no parameters are specified, all zone configuration information (both defined and effective) is displayed. Refer to cfgShow for a description of this display. Examples To display all zone aliases beginning with "arr": switch:admin> alishow "arr*" alias: array1 21:00:00:20:37 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 69
discussion is beyond the scope of this manual. The default parameters are optimal for most SAN applications; typical customers do not need to use this command. When used with no arguments, this command displays a list of APT policies supported on this switch, as well as the current policy. This - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 70
switch:admin> aptpolicy 1 Policy updated successfully. switch:admin> switchenable switch:admin> aptpolicy Current Policy: 1 3: Default Policy 1: Port Based Routing Policy 3: Exchange Based Routing Policy dlsReset, dlsSet, dlsShow, switchDisable 38 Fabric OS Command Reference Manual 53 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 71
address. Option [--class] allows 1-ZONE, 2-SECURITY, 3-CONFIGURATION, 4-FIRMWARE and 5-FABRIC filters. The execution of this command is subject to configuration switch:admin> auditcfg --class 2,3 Audit filter is configured. switch:admin> auditcfg --disable Audit filter is disabled. switch:admin - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 72
no protocol is set, the default setting of "fcap, dhchap" is used. When no group is set, the default setting of "*" (meaning switch does not support the authentication, then the E-port bring up will continue without authentication. Values include: off Turns off the authentication and the switch - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 73
. Values include: slotnumber Specify the slot number for slot-bases switches. portnumber For directors, use director based switch, use the slot and port format for specifying the port number: switch:admin> authutil --authinit 0/s1, 0/2 portShow, secAuthSecret Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 74
until this test is completed. This command is supported only on Brocade 24000 platforms. The execution of this command is default value is to disable the mode. Examples To test backplane connections on a Brocade director: switch:admin> backplanetest -ports 1/16, 18, 20 Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 75
backplaneTest 2 DATA TIMEOUT XMIT Refer to the Fabric OS Message Reference for more information. See Also itemList Fabric OS Command Reference Manual 43 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 76
value is all user ports. Refer to itemList for more information. -lb_mode mode Selects the loopback point for the test. By default, backport uses internal loopback. Mode Description 1 Port loopback (loopback plugs) 2 External (SERDES) loopback 44 Fabric OS Command Reference Manual 53 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 77
. The default value is 1. Description Single frame spinfab frames spinfab 1K frames Specifies external-test-only mode. The default value is 0, each link. Examples To test for backend ASIC pair links: switch:admin> backport -ports 1/1-1/3 -nframes 840 One moment please ... Manual 45 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 78
"My banner" switch:admin> bannerSet Please input context of security banner (press "." RETURN at the beginning of a newline to finish input): Do not log into this switch if you are not an authorized administrator. . See Also bannerShow 46 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 79
of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To display the banner for a switch: switch:admin> bannershow Banner: Do not log into this switch if you are not an authorized administrator. See Also bannerSet Fabric OS Command Reference - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 80
example, from a switch with 128 ports, the member ports consist of ports 7, 13, 42, 84, 85, and 86. The final Member Ports bit set represents the embedded port (frames sent to be handled by firmware) and is typically set. See Also portRouteShow 48 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 81
beaconing mode for one blade. When beaconing is enabled, the port LEDs flash amber in a running pattern from left to right and right to left. switch:admin> bladebeacon 2 1 switch:admin> bladebeacon 2 value = 1 switch:admin> bladebeacon 2 0 See Also switchShow Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 82
to slow flashing yellow as each port of the blade disables. A blade cannot be disabled or enabled when the switch is disabled or when the blade itself is faulted, powered off, 2 ENABLED See Also bladeEnable, portDisable, portEnable, switchShow 50 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 83
the power- flashing amber as each port enables. The LEDs change to green for online ports, unlighted for disconnected ports, or amber for ports that do not initialize. A blade cannot be disabled or enabled when the switch is disabled or when the blade itself is faulted, powered setting: switch:admin> - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 84
2 bladeEnable See Also 6 CP BLADE 1 ENABLED 7 SW BLADE 2 ENABLED 8 UNKNOWN VACANT 9 UNKNOWN VACANT 10 UNKNOWN VACANT bladeDisable, portDisable, portEnable, switchShow 52 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 85
and diagSetCycle. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands The operand is a follows: slotnumber A nonzero value that specifies the slot number from which to clear burn-in errors. Examples To clear burn-in errors from slot - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 86
Use this command to display errors stored in the nonvolatile memory on the slot during burn-in. Operands The operand is as follows: slotnumber A nonzero value that specifies the slot number from which to display burn-in errors. Examples To display burn-in errors from slot - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 87
value other than 0, the diagnostic daemon program performs burn-in testing in place of the power-on self-test (POST) phase II each time a switch blade is powered to returning a board for service. For multibladed products, this level sets to this value. -show If specified, level: switch:admin> - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 88
all slots are displayed. Examples To display the burn-in status for all slots: switch:admin> burninstatus Slot State Status Run 1 ABORT PASS 3 2 ABORT PASS 3 burnin burnin To display the burn-in status for slot 3: switch:admin> burninstatus --slot 3 Slot State Status Run 3 ABORT PASS - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 89
an enabled switch. You must first disable the switch using the switchDisable command. This command is supported only on the Brocade 3250, to perform this test. The default value is 1. -txport itemlist Specify a list of blade ports to test. By default, all the blade ports in Manual 57 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 90
2 camTest Refer to the Fabric OS Message Reference for more information. See Also centralMemoryTest, cmemRetentionTest, cmiTest, itemList, portLoopbackTest, portRegTest, spinSilk, sramRetentionTest 58 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 91
executed on an enabled switch. You must first disable the switch using the switchDisable command. This command is supported only on the Brocade 3250, 3850, 3900 ensure that each data bit is toggled during the test. The default pattern used (by POST also) is a QUAD_RAMP with a seed value of 0. ASIC- - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 92
and its error flag and interrupt bits set. The test method is as follows: Clear the error and interrupt bits of all ASICs. Set up the ASIC X in the switch: Write a 64-byte pattern in the central memory. Read X from all ASIC Y in the switch. For ASIC X, ensure: interrupt status bits set. the error - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 93
used. The default seed value is 0. Examples To test the ASIC central memory: switch:admin> centralmemorytest -ports 1/0-1/15 Running centralmemorytest Test Complete: centralmemorytest Pass 1 of 1 Duration 0 hr, 0 min & 3 sec (0:0:3:158). passed. Fabric OS Command Reference Manual 61 53-1000436 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 94
CM_ERR_TYPE TIMEOUT Refer to the Fabric OS Message Reference for more information. camTest, cmemRetentionTest, cmiTest, itemList, portLoopbackTest, portRegTest, spinSilk, sramRetentionTest 62 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 95
configuration is built when a specified zone configuration is enabled. This command requires a Brocade Advanced Zoning license. When security is enabled, this command can be issued on any switch in the fabric. Operands none Examples To display the effective zone configuration information - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 96
For the change to be preserved across switch reboots, it must be saved to nonvolatile Brocade Advanced Zoning license. When security is enabled, this command can be issued only from the primary FCS switch new zones to the configuration "Test_cfg": switch:admin> cfgadd "Test_cfg", "redzone; bluezone - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 97
creates the default zoning objects. This command requires a Brocade Advanced Zoning license. When security is enabled, this command can be issued only from the primary FCS switch. Operands none n): [no] n See Also cfgDisable, cfgEnable, cfgSave Fabric OS Command Reference Manual 65 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 98
. For the change to be preserved across switch reboots, it must be saved to nonvolatile Brocade Advanced Zoning license. When security is enabled, this command can be issued only from the primary FCS switch create a configuration containing three zones: switch:admin> cfgcreate "USA_cfg", "Red_zone; - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 99
. For the change to be preserved across switch reboots, it must be saved to nonvolatile Brocade Advanced Zoning license. When security is enabled, this command can be issued only from the primary FCS switch Examples To delete a zone configuration: switch:admin> cfgdelete "USA_cfg" See Also cfgAdd - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 100
aborted. A message is displayed on the other switches to indicate the aborting of the transaction. If the default zone access mode is "No Access", then this command becomes cfgEnable "d_efault_Cfg". See defZone. This command requires a Brocade Advanced Zoning license. When security is enabled, this - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 101
requires a Brocade Advanced Zoning license. When security is enabled, this command can be issued only from the primary FCS switch. Operands y zone config "USA_cfg" is in effect Updating flash ... See Also cfgClear, cfgDisable, cfgSave, cfgShow Fabric OS Command Reference Manual 69 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 102
. For the change to be preserved across switch reboots, it must be saved to nonvolatile Brocade Advanced Zoning license. When security is enabled, this command can be issued only from the primary FCS switch To remove a zone from a configuration: switch:admin> cfgremove "Test_cfg", "redzone" See - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 103
switches in the fabric. The saved configuration is automatically reloaded by the switch on power switch is automatically aborted. A message is displayed on the other switches to indicate the aborting of the transaction. This command requires a Brocade n): [no] n Updating flash ... See Also cfgAdd, - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 104
enabled and all error checking has been completed successfully. When default zoning is enabled with "No Access" mode, "No command requires a Brocade Advanced Zoning license. When security is enabled, this command can be issued on any FCS switch in the Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 105
current transaction) or specify 1 to display the contents of nonvolatile memory. The default value is 0. This operand is optional. Examples To display all zone configurations that start with "Test": switch:admin> cfgshow "Test*" cfg: Test1 Blue_zone cfg: Test_cfg Red_zone; Blue_zone To display - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 106
configuration to all switches in the defined configuration. This value will be nonzero Brocade Advanced Zoning license. When security is enabled, this command can be issued only from the primary FCS switch AD255 context: switch:admin> cfgsize information in AD255 context: switch:admin> cfgsize Zone DB - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 107
different switch in the fabric when this command is run, the transaction on the other switch remains open and unaffected. This command requires a Brocade Advanced a transaction. Examples To abort the current transaction: switch:admin> cfgtransabort See Also cfgAdd, cfgClear, cfgCreate, cfgDelete - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 108
it is an internal zoning transaction. This command requires a Brocade Advanced Zoning license. When security is enabled, this command can be issued only from the primary FCS switch. Operands none Examples To display the current transaction: switch:admin> cfgtransshow There is no outstanding zone - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 109
directors support options 1 and 5: NOTE Option 5 is not possible for Brocade 2400. Use option 2 for dual domain and option 1 for single domain. Only option 1 supports both FC2-16 and FC4-16. 1 One 128-port switch (blade ID 4, 17 on slots 1 - 4 and 7 - 10; blade ID 5, 16 on slots 5 - 6) 2 Two 64 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 110
to the factory default user accounts and passwords. The execution of Brocade 48000 director and to change the option: switch:admin> chassisconfig Current Option: 5 All Supported Options (With Blade ID 5 on slots 5-6 Option 1: One 128-port switch (Blade ID 4, 17 on slots 1-4, 7-10, Blade ID 5, 16 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 111
chassisConfig 2 Are you sure you want to continue? (Y/N): y Current Option changed to 1 Restoring switch 0 configuration to factory defaults... done. (Telnet connection goes down at this point.) See Also configDownload, configUpload, slotShow Fabric OS Command Reference Manual 79 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 112
the chassis. In dual-domain systems, there are up to two logical switches associated with a single chassis. Operands This command has the following operand name to "dilbert": switch:admin> chassisname dilbert Please wait while committing configuration... switch:admin> chassisname dilbert See - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 113
Object type: CHASSIS, FAN, POWER SUPPLY, SW BLADE (switch), CP BLADE (control processor), Value to calculate the object's power consumption: positive for power supplies and negative for consumers. Power 20 characters): Part Num: xxxxxxxxxxxxxxxxxxxx 13 Externally supplied serial number (up to 20 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 114
16 days 555-374757 234-294-12345 2734658 A.00 CP BLADE Slot: 6 Header Version: Power POWER SUPPLY Unit: 2 Header Version: Power : Power Consume 16 days 555-374757 238-298-12360 1234567 1 -50 20-123456-12 B014934500 Day: 6 Month: 7 Year: 2001 Day: 15 Month: 7 Year: 2001 88 days 16 days 456-777888 230 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 115
specified blade slot. The output of this command is for support use only. The command is supported only on Brocade 200E,3250, 3850, 3900, 4100, 24000, and 48000 the index of the chip within the specified blade to display. The default is set to 0 and designed to operate on fixed-port-count products - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 116
seed to be used. The default seed value is 0. Examples To run the data-retention test on the central memory SRAMS: switch:admin> cmemretentiontest --slot 7 Running cmemretentiontest Test Complete: cmemretentiontest Pass 1 of 1 Duration 0 hr, 1 min & 33 sec (0:1:33:16). passed. Diagnostics The - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 117
cmemRetentionTest 2 LCMEM_ERR LCMRS_ERR LCMTO_ERR Refer to the Fabric OS Message Reference for more information. See Also camTest, centralMemoryTest, cmiTest, dataTypeShow, itemList, portLoopbackTest, spinSilk, sramRetentionTest Fabric OS Command Reference Manual 85 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 118
bit in any ASIC pair. The CMI is used to send transmission requests or completion messages between the ASIC transmitter and receiver. This command is supported only on Brocade itemlist Specifies a list of ports to receive data. By default, all the ports in the specified slot (--slot) are used - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 119
cmiTest 2 See Also camTest, centralMemoryTest, cmemRetentionTest, itemList, portLoopbackTest, spinSilk, sramRetentionTest Fabric OS Command Reference Manual 87 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 120
command on the Brocade 7500, it persistently disables the ports. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To restore the system configuration to default values: 88 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 121
switch:admin> configdefault Committing Configuration ...done. See Also agtCfgDefault, configure, switchDisable, switchEnable configDefault 2 Fabric OS Command Reference Manual 89 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 122
configDownload command supports DNS names FOS that does not support IPv6. To be password if necessary. The SSH service is also available on Unix and Windows hosts. For Admin Domain users, refer to the Fabric OS Administrator's Guide switch before proceeding). • The host name is not known to the switch - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 123
switches in the fabric. After the switch is enabled, if the switch switch's identity cannot be changed by configDownload. Parameters such as the switch switch performing switch values within the range displayed against each parameter. This command validates the modified values FTP is the default. "host" - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 124
directory on which the FTP server is running on Windows hosts. Specifies the password for the FTP login. Examples To download a configuration file interactively, on an AD-aware switch running Fabric OS v5.3.0: switch:admin> configdownload Protocol (scp or ftp) [ftp]: ftp Server Name or IP Address - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 125
for some parameter changes to take effect. Do you want to continue [y/n]: y configDownload completed successfully. All parameters are downloaded. switch:admin> switchenable switch:admin> configDefault, configShow, configUpload, configure Fabric OS Command Reference Manual 93 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 126
items set by the configure command. Not all values displayed are applicable to all system models and and other common regular expression operators is not supported. Some configuration settings will not display selectively in settings for "passwdcfg": switch:admin> configshow " Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 127
diag.script.SWITCH.POST2:switchpost2.sh diag.test.crossPort.passes:5000 diag.test.passes:0 diag.test.portLoopback.passes:1000 diag.test.silkScreen.passes:180 diag.test.spinSilk.passes:120 ether.link.mode:AUTO fabric.domain:2 fabric.ididmode:0 fabric.ops.BBCredit:16 fabric.ops.E_D_TOV:2000 fabric.ops - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 128
.DomRscnToDevForSwChg.enable:0 ns.EndDeviceRscnFormat:1 oemLogo:0 perf.cfgver:1 perf.eemonchks:0 (output truncated) See Also agtCfgShow, configure, diagDisablePost, diagEnablePost, ipAddrShow, licenseShow, syslogdIpShow 96 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 129
SCP will prompt for the password if necessary. The SSH service is also available on Unix and Windows hosts. This command can be invoked without any operands, creating an interactive session. The upload might fail for the following reasons: • The host name is not known to the switch. • The host IP - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 130
switch boot parameters, also known as the switch's identity. It has variables such as the switch switch Administrator's Guide for is not specified, FTP is the default. "host" Specifies a host "passwd" Specifies the password for the FTP login file interactively: switch:admin> configupload Protocol - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 131
2 See Also File Name [config.txt]: config.txt Password: ******** configUpload complete: All config parameters except AD Headers,SFOS, and Security parameters are uploaded from AD0 configDefault, configDownload, configShow, configure Fabric OS Command Reference Manual 99 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 132
or the timeout values, can be changed for specific applications or operating environments but must be in agreement among all switches to allow formation of the fabric. The Switch Fabric Settings are as follows: TABLE 2 Configure Command Fabric Parameters Field Type Default Range Domain R_A_TOV - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 133
Default 2000 0 7 2112 0 0 0 1 0 0 16 0 0x0 Range 1000 to R_A_TOV / 2 0 to R_A_TOV / 4 7 to 19 256 to 2112 0 or 1 0 or 1 0 or 1 1 to 2 0 or 1 0 or 1 1 to 27 0 or 1 0x0-0xffff Descriptions of the switch E_D_TOV Error detect time out value (E_D_TOV) is displayed in Manual 101 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 134
on, Class F traffic is converted to Class 2 traffic before being transmitted. Switch PID Format The formats are as follows: 0 Native PID Format (16 based, 16 port format), for fabrics with legacy low-count port switches. 1 Core PID Format (0 based, 256 port format), preferred mode for mixed - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 135
the slot blade or CP blade (if dual core switch) using this new "BLADE_FAULT_ON_HWERRMSK" in the switch internal functions and are not available for modification. The default virtual channel settings have already been optimized for switch performance. Changing the default values can improve switch - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 136
Mode Domain RSCN to End-device for switch IP address or name change Type number number Default 1 0 Range 0 to 2 0 to 1 End-device RSCN Transmission Mode Values are as follows: 0 RSCN only contains available. This is required for TachLite. 104 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 137
The retrieval of this information is supported by a number of operating systems that support RPC. On most UNIX-based systems (HP-UX, Irix, Linux, Solaris, switch, including sectelnet. If you are using SSH to manage a switch, you can disable the telnet interface for greater security. The default value - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 138
File Type Default Range 128 Yes/No On/Off 0, 1, 2 On/Off On/Off On/Off The secure protocols must not be enabled before setting SSL attributes correctly. Operands none Examples To modify configuration settings on a switch: switch:admin> configure configure System services Reference Manual 53 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 139
into port N's receiver, thus exercising all the switch components, from the main board, to the test is running. The command is supported only on Brocade 200E,3250, 3850, 3900,4100 Class 3 receiver counters are stuck at some value. Check if the number of frames transmitted is Manual 107 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 140
which components of the switch are faulty. It is default, crossPortTest uses mode 1 port loopback. Valid values are: 0 Cable loopback 1 Port loopback (loopback plugs) 2 External (SERDES) loopback 3 Silkscreen loopback 5 Internal (parallel) loopback 108 Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 141
should normally be left at the default value of 0. Specify a list of user ports to test. By default, all the user ports in the current switch will be used. Refer to , cmiTest, itemList, portLoopbackTest, portRegTest, spinSilk, sramRetentionTest Fabric OS Command Reference Manual 109 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 142
value] Description Use this command to display sample data stream types used in diagnostic commands. There are 20 value Specify the data pattern seed value. If no seed is specified, then a seed value of 0 is used. Examples To display sample data streams you can use with diagnostics: switch 16 16 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 143
support. If the switch is operating in FICON Management Server mode (fmsmode), setting the date is subject to the director clock hour, 00-23; MM is minutes, 00-59; yy is the year, 00-99. Year values greater than 69 are taken to indicate 1970-1999; year values less than 70 are taken to indicate 2000 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 144
2 date See Also Thu Feb 27 12:30:00 UTC 2003 errShow, ficoncupset, ficoncupshow, portLogShow, tsClockServer, tsTimeZone, upTime 112 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 145
dbgshow [module_name] Description Use this command to display the current values of debug and verbosity levels of the specified module. If no . Examples To display information about a specific module named NS: switch:admin> dbgshow NS Module NS, debug level = 1, verbose level = - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 146
you issue a cfgDisable of the current effective zone configuration, the local switch converts it into a cfgEnable d_efault_Cfg command. When zoning receives a cfgDisable command from a remote switch that does not support default zoning, zoning rejects the cfgDisable command in the second phase of - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 147
> cfgactvshow Effective configuration: no configuration in effect switch:admin> defzone --noaccess switch:admin> cfgsave switch:admin> defzone --show Default Zone Access Mode committed - No Access transaction - No Transaction See Also none Fabric OS Command Reference Manual 115 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 148
:00:00:00:01" aliCreate "d_efault_Zone_Alias", "1,0" This command requires a Brocade Advanced Zoning license. When security is enabled, this command can be issued only from the primary FCS switch. Names with the "d_efault" prefix are reserved for default zoning use. cfgShow shows the names of the - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 149
zone configuration. Operands None Examples To delete a default zone configuration: switch:admin> cfgactvshow Effective configuration: no configuration in effect switch:admin> defzonedelete switch:admin> cfgactvshow See Also defZoneCreate Fabric OS Command Reference Manual 117 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 150
--slot slotnumber Specify the slot to clear the diagnostics failure status. The default is set to 0 and designed to operate on fixed-port-count products. operand is specified, the default is to clear all bad port flags. Examples To clear the diag software flag: switch:admin> diagclearerror 8 ERROR: - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 151
the FR4-18i blade in a Brocade chassis; however, the command is not supported by the Brocade platform and does not effect diagnostic commands, with descriptions: switch:admin> diagcommandshow bladepropshow display mini-switch ASIC property minisregshow display contents of mini-switch registers - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 152
command to disable POST. A reboot is not required for this command to take effect. Operands none Examples To disable the POST during future power ons: switch:admin> diagdisablepost Config update Succeeded Diagnostic POST is now disabled. See Also diagEnablePost 120 Fabric OS Command Reference - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 153
diagEnablePost 2 diagEnablePost Enables power-on self-test (POST) execution at next reboot. Synopsis diagenablepost may be in place. Operands none Examples To enable the POST during future power ons: switch:admin> diagenablepost Config update Succeeded Diagnostic POST is now enabled. See Also - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 154
Specify the value for the relevant diagnostic environment variable. Examples To display the values of the diagnostic parameters: switch:admin> diagshowusr Name Environment USR_DILATION DIAG_USR_DLY_DILATION USR_MEMDLY DIAG_USR_MEMDLY Value 1 10 122 Fabric OS Command Reference Manual 53 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 155
See Also USR_SEED DIAG_USR_SEED USR_SPECIAL DIAG_USR_SPECIAL (output truncated) none diagEnv 2 0x0 0x0 Fabric OS Command Reference Manual 123 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 156
limit to a specified value. The fail limit The fail limit is saved in flash memory and stays set until the diagnostic test aborts. The limit value must be 1 or greater. value is displayed. Examples To change the fail limit from 1 to 5: switch:admin> diagfaillimit -show Fail Limit is 1. switch - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 157
default operands when running diagnostics commands. Nondefault settings require detailed knowledge of the underlying hardware and are intended for support personnel only. Contact support diagnostic command information: switch:admin> diaghelp bladepropshow Reference Manual 125 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 158
to be used by FL mode diagnostics. The value entered will be converted from a loop ID to blade in a Brocade chassis; however, the command is not supported by the Brocade platform and does is specified, the current value is displayed. Examples To display the loop ID: switch:admin> diagloopid -show - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 159
on the FR4-18i blade in a Brocade chassis; however, the command is not supported by the Brocade platform and does not effect any other feature none Examples To display the diagnostic mode: switch:admin> diagmodeshow diag.mode* parameters saved in flash: diag.mode.burnin diag.mode.burnin.level - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 160
value is displayed. Examples To enable and then disable the POST test: switch:admin> diagpost Diagnostic POST is currently disabled. switch:admin> diagpost 1 Config update Succeeded Diagnostic POST is now enabled. See Also diagDisablePost, diagEnablePost 128 Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 161
the mode value is 0. The mode is saved in flash memory (and stays in that mode) until the next execution of diagRetry. The mode becomes active as soon as this command is executed; it does not require a reboot to take effect. Retry mode modifies the behavior of the diagnostic test methods, power-on - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 162
flash memory. The activity log of the script is saved in /var/log/scriptname.slot.log. The errors produced are available from the burninErrShow command on a per-blade basis. When power cycles set the burn-in script and mode: switch:admin> diagsetburnin --slot 1 -current existing Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 163
default values. -keyword value The script parameters can be updated noninteractively using this style of option list. value is the keyword to update; the value should be specified manually in this case. Examples To update diagnostic command parameters: switch : 200 20 - bpt_nframes : 20 50 - - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 164
the user ports specified in -uports displays. The default value is 0. Examples To display diagnostic status on a switch blade: switch:admin> diagshow Diagnostics Status: Fri Feb 08 15:25 2G Auto ...... (output truncated) See Also itemList 132 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 165
value is not 0) or disable the show-time mode (if the mode value is set to 0). The mode is saved in flash Brocade chassis; however, the command is not supported by the Brocade value is displayed. Examples To enable show-time mode: switch:admin> diagshowtime Show Time mode is 0 (Disabled). switch - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 166
execution of certain POSTs that might prove hazardous to normal switch operation. The exact use of this flag is determined by the POST scripts and the specific test methods used. Operands This command has the following operands: value Specify a bit mask for tests to skip. -show If specified or - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 167
FR4-18i blade in a Brocade chassis; however, the command is not supported by the Brocade platform and does not effect are assumed. Examples To display currently running diagnostic tests: switch:admin> diagstatus Diagnostic status for slot: 1. Diag OS Command Reference Manual 135 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 168
Switch: 0, Error DIAG-MANUAL1, 1, " 1 Starting switchess ... Err# 0140042 0100:101:000:001:24:37: 0xc84 (fabos): Dec 20 08:57:27 Switch: Switch: 0, Error DIAG-MANUAL1, 1, " 1 switchess: ABORT ... Err# 0140042 0100:101:000:002:26:41:1N See Also diagSetBurnin 136 Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 169
:admin> distribute -p "SCC;DCC" -d "3;5" To distribute the Switch Connection Control Policy, FCS Policy, and Password database to all domains in the fabric that support the distribute feature: switch:admin> distribute -p "SCC;FCS;PWD" -d "*" Fabric OS Command Reference Manual 137 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 170
1 3 5 To distribute the Switch Connection FCS policy and Password database to all domains in the fabric that support the distribute feature: switch:admin> distribute -p "FCS;PWD" -d "*" To distribute the AUTH amd FCS policies to all v5.3. switches in the fabric. switch:admin> distribute -p "AUTH;FCS - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 171
the fabric cannot handle occasional routing changes correctly. DLS is not supported in certain routing policies. Refer to aptPolicy for more information on To disable the dynamic load sharing option: switch:admin> dlsreset Committing configuration...done. switch:admin> dlsshow DLS is not set See - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 172
setting. The DLS option is on by default. DLS is not supported in certain routing policies. Refer to aptPolicy switch:admin> dlsset switch:admin> dlsshow DLS is set See Also aptPolicy, dlsReset, dlsShow, iodReset, iodSet, iodShow, uRouteShow, topologyShow 140 Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 173
balance. Refer to dlsSet for a description of load sharing. DLS is not supported in certain routing policies. Refer to aptPolicy for more information on routing policies. The the current DLS option setting: switch:admin> dlsshow DLS is set See Also dlsSet, dlsReset Fabric OS Command Reference - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 174
the domain name service parameters. The domain name service parameters are the parameters for the system: switch:admin> dnsconfig Enter option 1 Display Domain Name Service (DNS) configuration 2 successfully Enter option 1 Display Domain Name Service (DNS) configuration 2 Set DNS configuration - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 175
attribute Description Use this command to display attributes of the switch enclosure. Currently, supported attributes are the vendor-specific enclosure identifier and the identifier of the enclosure interface to which the switch is attached. This command is only meaningful for the products - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 176
used by the enclosure manager. Displays whether or not the switch has a fuse. Examples See Also To display the identifier of the enclosure interface to which the switch is attached: switch:admin> enclosureShow slotid Bay 4 chassisShow 144 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 177
instances on this control processor (CP). Synopsis errclear Description Use this command to clear all internal and external error log messages for all switch instances on this CP. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 178
operand is optional. Examples To display the start and end delimiter: switch:admin> errdelimiterset delimiter start string: delimiter end string: See Also To change the start and end delimiter (with sample output): switch:admin> errdelimiterset -s "Start" -e "End" Start2003/03/10-09:54 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 179
in the field. Severity Severity of the message. Valid values include INFO, WARNING, ERROR, and CRITICAL. Switch name Switch name for the generator of this message, or "chassis via SERIAL. See Also errDelimiterSet, errFilterSet, errShow Fabric OS Command Reference Manual 147 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 180
" Specify the minimum severity level of the message to pass through the filter. Valid values are "INFO", "WARNING", "ERROR", or "CRITICAL". Examples To display the current filter settings: switch:admin> errfilterset console: filter severity = WARNING See Also To set the filter severity level - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 181
that may be in place. Operands none Examples To display a list of all defined error log modules: switch:user> errmoduleshow KT UT TRCE KTRC LOG CDR BLPU PISP PIXE EGR BL PIC PS RTE AS AUTH BLDE (output truncated) See Also errDump, errShow Fabric OS Command Reference Manual 149 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 182
in the field. Severity Severity of the message. Valid values include INFO, WARNING, ERROR, and CRITICAL. Switch name Switch name for the generator of this message, or "chassis". CR> to stop: See Also errDelimiterSet, errDump, errFilterSet 150 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 183
exit command is an accepted synonym for logout, as is typing Ctrl-D at the beginning of a line. Operands none Examples To exit from a shell session: switch:admin> exit Connection to host lost. See Also logout Fabric OS Command Reference - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 184
received from the port 0x00000100 Port truly connected to E_Port 0x00000200 Segmented by routing code 0x00000400 fspf has completed routing 152 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 185
isolation nbrWWN Neighboring switch's WWN nbrPort Neighboring switch's port lr_tid that are connected to the same neighboring switch The execution of this command is subject ports. Examples To display fabric port information: switch:admin> fabportshow 4/14 Fabric Port Information Port: - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 186
2 fabPortShow See Also Flags: nbrWWN: nbrPort: lr_tid: red_ports: 10 11 62 63 0x280120 10:00:00:60:69:80:06:cf 5 0x1005dbd8, IDLE STATE Open commands pending No commands pending portShow 154 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 187
this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To display the retry count of Fabric OS commands: switch:user> fabretryshow SW_ILS E_Port ELP EFP HA_EFP DIA RDI BF FWD EMT ETP RAID GAID ELP_TMR GRE ECP - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 188
--disable Disables fabric log. By default, the fabric log is enabled. -e a power of 2; otherwise, the command fails. Examples To change the number of entries: switch:admin> 01:08:52.977 SCN Switch Offline A2,NA F2,NA switch:admin> fabriclog -r 64 Warning: This command will clear the logs - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 189
fabricLog 2 See Also Are your sure you want to do the resize [y/n]? y switch:admin> fabriclog -s Time Stamp Input and *Action S, P Sn,Pn Port Xid fabPortShow, fabStatsShow Fabric OS Command Reference Manual 157 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 190
mode setting: switch:admin> fabricprincipal 1 Principal Selection Mode enabled See Also To enable the mode setting and force fabric rebuild: switch:admin> fabricprincipal -f 1 Principal Selection Mode enabled (Forcing fabric rebuild) fabricShow 158 Fabric OS Command Reference Manual 53-1000436 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 191
field will be empty if the switch is not an FC Router of it the FC Router does not support it. The execution of this command 192.168.64.187 0.0.0.0 "sw187" The Fabric has 4 switches To show a mixed fabric with an IPv4 and IPV6 configured switches: sw5:admin> fabricShow Switch ID Worldwide Name - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 192
fabricshow -m Switch ID Name ENET IP Addr FC Router FC Router IP Addr Name 1: fffc01 fcr_sprint_01 10.33.59.224 160: fffca0 fcr_fd_160 0.0.0.0 10.33.59.25 fcr_meteor2 190: fffcbe fcr_mojo_6 10.33.59.32 The Fabric has 3 switches switchShow 160 Fabric OS Command Reference Manual 53 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 193
the fabric state information: switch:admin> fabstateshow Time Stamp Input and *Action S, P Sn,Pn Port Xid 11955:655 SCN Switch Online F2,NA F2,NA ACC Receive F2,P2 F2,P2 21 0x277 switch:admin> fabstateclear switch:admin> fabstateshow Time Stamp Input and *Action S, P Sn, - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 194
> fabstateresize 64 Warning: This command will clear the logs. Are your sure you want to do the resize [y/n]? y switch:admin> fabstateshow Time Stamp Input and *Action S, P Sn,Pn Port Xid See Also fabricLog, fabStateClear, fabStateShow 162 Fabric OS Command Reference Manual 53-1000436 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 195
Operands none Examples To display the fabric state information: switch:admin> fabstateshow Time Stamp Input and *Action S, P Sn,Pn Port Xid 11955:655 SCN Switch Online F2,NA F2,NA NA NA 11955:657 , fabStateResize, fabricLog Fabric OS Command Reference Manual 163 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 196
the fabric. The information displays as follows: Number of times a switch domain ID has been forcibly changed Number of E_Port offline transitions Overlap: 0 Zoning: 0 E_Port Segment: 0 Licensing: 0 Disabled E_Port: 0 Platform DB: 0 164 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 197
Sec Incompatibility: 0 Sec Violation: 0 ECP Error: 0 Duplicate WWN: 0 Eport Isolated: 0 See Also fabRetryShow fabStatsShow 2 Fabric OS Command Reference Manual 165 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 198
Switch State Structure Information State: D0 Stage: warm done Rdi Receive Timer: 0x10069400, IDLE STATE Unconfirmed Sw Timer: 0x10069508, IDLE STATE NTP Timer: 0x100695b8, IDLE STATE ME Timer: 0x10069610, IDLE STATE Principal Domain: 2 Upstream Port: 64 last message: 20:30:29.826 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 199
See Also supportShow fabSwitchShow 2 Fabric OS Command Reference Manual 167 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 200
speed to 0. This command is not available on nonbladed systems except for the Brocade 4100 and 4900. The execution of this command is subject to Admin Domain number to disable. Examples To disable a fan unit: switch:admin> fandisable 1 Fan unit 1 has been disabled See Also fanEnable - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 201
fan unit back to the default RPM speed. This command is not available on nonbladed systems except for the Brocade 4100 and 4900. The execution a fan unit: switch:admin> fanenable 1 Fan unit 1 has been enabled See Also fanDisable, fanShow Fabric OS Command Reference Manual 169 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 202
fan speed is displayed. The output from this command varies depending on switch type and number of fans present. The execution of this command is in place. Operands none Examples To display information on the fans in the system: switch:admin> fanshow Fan #1 is OK, speed is 2721 RPM Fan #2 is OK - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 203
2 fastboot Reboots the Control Processor (CP), bypassing Power-On Self-Tests (POST). Synopsis fastboot Description Use Processor, without executing POST on startup: switch:admin> fastboot See Also diagDisablePost, diagEnablePost, reboot Fabric OS Command Reference Manual 171 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 204
Brocade 7500). This command is supported only for FR4-18i and Brocade 7500 systems. The blade can be configured either to support FC fastwrite or FCIP (default supported a given slot: switch:admin> fastwritecfg --enable !!!! WARNING !!!! Enabling this feature requires power-cycling of the affected - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 205
requires power-cycling of the affected blade to take effect and may take up to 5 minutes to complete. Non-bladed switches will be rebooted. In all cases, data traffic on all the ports (FC and GbE) of the blade will be disrupted. Continue (Y,y,N,n): [ n] portcfg Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 206
arrays to "Blue_fazone": switch: switch:admin> fazoneadd "Blue_fazone", "H{5,6}" See Also To add another target member to "Blue_fazone": switch:admin> fazoneadd "Blue_fazone", "10:49:00:00:00:20:3f:2e" fazoneCreate, fazoneDelete, fazoneRemove, fazoneShow 174 Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 207
defined with the following members "2,12; 2,14; 10:00:00:60:69:00:00:8a" would contain devices connected to switch 2, ports 12 and 14, and the device with a WWN of "10:00:00:60:69:00:00:8a" ( specified by one or more of the following methods: Fabric OS Command Reference Manual 175 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 208
, "10:49:00:00:00:20:3f:2e"). Fabric Assist zone alias switch:admin> fazoneCreate "Blue_fazone", "H{1,1}; array1; 1,2; array2" switch:admin> fazoneCreate "Green_fazone", "1,0; loop1; H{1,2}; array2" See Also fazoneAdd, fazoneDelete, fazoneRemove, fazoneShow 176 Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 209
cfgEnable command. For the change to be preserved across switch reboots, it must be saved to nonvolatile memory can be issued only from the primary FCS switch. Operands This command has the following operands: fazonename a Fabric Assist zone: switch:admin> fazonedelete "Blue_fazone" See - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 210
. For the change to be preserved across switch reboots, it must be saved to nonvolatile issued only from the primary FCS switch. Operands This command has the WWNs (for example, "10:49:00:00:00:20:3f:2e"). Refer to fazoneCreate for more details on from "Blue_fazone": switch:admin> fazoneremove " - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 211
operand must be preceded by a pattern. This operand is optional; if omitted, the value defaults to 0. Examples To display all Fabric Assist zones beginning with the letters A through C: switch:admin> fazoneshow "[A-C]*" fazone: Blue_fazone 1,1; array1; 1,2; array2 See Also fazoneAdd, fazoneCreate - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 212
supported only on Brocade FR4-18i blades and Brocade test. By default, all GbE ports in the specified slotnumber are used. Valid number values include: 0 GbE port 0 1 GbE port 1 2 All GbE port Examples To run all tests on slot 7 and GbE port 1: switch Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 213
See Also fcipPathTest fcipChipTest 2 Fabric OS Command Reference Manual 181 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 214
supported only on Brocade FR4-18i blades and Brocade default, all GbE ports in the specified slotnumber are used. Valid number values default value is 100. -length data_length Specifies the data length of the frames used in the test. The default for the test. By default, data compression is used. - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 215
might report one or more of the following: PATH_TEST_ERR PATH_TEST_CHIP_INIT_ERR PATH_TEST_IMAGE_ERR PATH_TEST_TIMEOUT_ERR PATH_TEST_HEARTBEAT_ERR PATH_TEST_INVALID_RESULT PATH_TEST_GE_PORT_ENABLE_ERR PATH_TEST_GE_PORT_DISABLE_ERR fcipChipTest Fabric OS Command Reference Manual 183 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 216
LUN query from this switch. Examples To display the LUN information: switch:user> fclunquery Target Index switch:admin> fclunquery -w 20:00:00:04:cf:5d:cf:0e Target Index: 1 Target Node WWN: 20 switch: switch:admin> fclunquery -s The following WWNs will be used for any lun query from this switch - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 217
and the destination identifier is either source or destination. The echo ELS might not be supported on all devices. In such cases, the response could be either an ELS reject or a request timeout. By default, fcPing sends five ELS Echo requests to each port. When a device does not respond to - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 218
that accepts the request and another device that rejects the request: switch:admin> fcping 10:00:00:00:c9:29:0e:c4 21:00:00:20:37:25:ad:05 Source: 10:00:00:00:c9:29:0e frames timeout Round-trip min/avg/max = 0/0/0 usec gettimeofday, ping 186 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 219
execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To clear the FCPD debug information log: switch:admin> fcplogclear See Also fcpLogDisable, fcpLogEnable, fcpLogShow Fabric OS Command Reference Manual 187 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 220
execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To disable the FCPD debug information log: switch:admin> fcplogdisable See Also fcpLogClear, fcpLogEnable, fcpLogShow 188 Fabric OS Command Reference - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 221
(debug command). Synopsis fcplogenable Description Use this command to enable the debug information logged for FCPD. Debug information logging is enabled by default. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To enable the - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 222
FCPD debug information log: switch:admin> fcplogshow Time Stamp 3436 2 :0 :0 :0 :0 22:34:14.232 FlshOrProbe 26 1 459 80 :0 :0 :0 :0 22:34:14.232 PrbMsg 26 1 494 0 :0 :0 :0 34:14.236 ElsRsp 26 1 1606 11ace :2000000 :20 :0 :980000 22:34:14.238 SndPRLI 26 1 Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 223
to list valid ports. This operand is required. Examples To display the FCP probe information: switch:admin> fcpprobeshow 4/4 port 52 is L-Port and it is online. nodes probed: 2 successful IBM DDYF-T09170R F60N portLoginShow, portLogShow Fabric OS Command Reference Manual 191 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 224
to its slot for bladed systems. Use switchShow to list valid ports. This operand is required. Examples To display the FCP RLS information: switch:admin> fcprlsshow 2/5 0xda 0xdc link fail 0 0 loss sync 5 3 loss sig 0 0 prtc err 0 0 bad word 525 330 crc err 0 0 See Also portLoginShow - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 225
values are 1-128. --help Displays the list of actions possible. EXAMPLES To display the current configuration of the switch. switch:admin> frcbcastconfig --show Broadcast configuration is disabled for: fid 2 fid 128 fid 33 SEE ALSO bcastshow, portRouteShow Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 226
bit (to 0x00000002), repeat the write, read, and compare the cycle. Shift again and repeat until the last writable bit in register N is reached (0x80000000 for a 32-bit register). For example, a 6-bit . This command is supported only on Brocade FR4-18i blades and Brocade 7500 platforms. Operands - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 227
, the test might report one or more of the following: DMA_ALLOC_FAIL DMA_READ_ABORT DMA_READ_TIMEOUT CHIP_INIT_TIMEOUT BIST_TIMEOUT BIST_FAIL See Also fcrPathTest, miniCycle, portLoopbackTest Fabric OS Command Reference Manual 195 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 228
fabric is the fabric attached to the U_Ports-for example, E/F_Ports-of this switch. The backbone fabric ID must be unique across all FC Router-connected fabrics. cr> to skip a parameter Backbone fabric ID: (1-128)[100] See Also fosConfig, switchDisable, switchEnable, switchShow 196 Fabric OS - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 229
service on a switch. This command is not supported in v5.3.0; instead use fosConfig. Synopsis fcrdisable Description Use this command to disable Fibre Channel (FC) routing on a switch. This command can be run while the switch an XPath OS switch is in the BB : "FC Routing service is in the process - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 230
Enables the FC Routing service on the switch. This command is not supported in v5.3.0; instead use fosConfig. Synopsis fcrenable Description Use this command to enable the Fibre Channel (FC) Routing service on a switch. In Fabric OS v5.1 the FC Routing service is enabled by default. In Fabric OS - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 231
support switch Switch Info (WWN, enet IP, name) The WWN, Ethernet IP address, and switch name of the switch attached to the EX_Port. Operands none Examples To display the FC Routers in the backbone fabric: switch FID Neighbor Switch Info (enet Switch Info (enet - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 232
set or display the maximum number of LSAN zones that can be configured on the router. By default, this limit is set to 3000, which is also the minimum. This parameter can have the maximum value set to 5000. The maximum LSAN count limit is also displayed with command fcrresourceshow. Only 3000 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 233
switch and not distributed to other FCR switches automatically. The best practice is to enter the same information for all the FCR switches in the backbone that supports value. Display the information that is saved in the persistent memory (CLI command with no option). Display the static and default - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 234
applied; revert to the persistent information. Views all the static and default/dynamic fabric binding in the backbone. Verifies if the LSAN Zone static and default/dynamic binding in the backbone: For example, in the backbone where online fabrics are: 1, 2, 4, 5, 7, 8, 10 switch:admin > - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 235
19 Default LSAN Matrix: 1 2 8 Example of a quick mode: switch:admin > fcrproxydevshow -a Proxy WWN Proxy Created PID Exists in Fabric in Fabric Device PID Physical State 52 10:00:00:06:2b:0e:4d:e5 52 10:32:16:90:28:dd:d0:03 52 10:32:16:91:24:dd:d0:07 52 10:32:16:91:25 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 236
Check if the transmit, receive, or Class 3 receiver counters are stuck at some value. Check if the number of frames transmitted is not equal to the number of frames ... CQTR_SQ0x78, 0x78, 0x78, 0x78, ... CRPAT 0xbc, 0xbc, 0x23, 0x47, ... 204 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 237
test progresses until the specified number of frames are transmitted on each port. The default value is 10. Examples To test slot 2 with FC Router FPGA Serdes loopback sending 10 frames: switch:admin> fcrpathtest --slot 2 -path 2 -nframes 10 Running fcrpathtest Test Complete: fcrpathtest Pass 10 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 238
to EX_Ports of FC Routers on the same backbone fabric as this FC Router. The default output displays only physical device information relevant to this FC Router. Relevant physical devices include fcrphydevshow Device WWN Exists Physical PID 206 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 239
fcrPhyDevShow 2 in Fabric 2 10:00:00:00:c9:2b:6a:68 c70000 3 50:05:07:65:05:84:09:0e 0100ef 3 50:05:07:65:05:84:0b:83 0100e8 Total devices displayed: 3 See Also fcrFabricShow, fcrProxyDevShow, fcrRouteShow, lsanZoneShow, switchShow Fabric OS Command Reference Manual 207 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 240
value or the low 8-bits of the proxy device address (valid values include 01H through 7FH). The address of the proxy device is derived from the PID format (for example, native, core 7FH]) for the edge fabric specified (1 through 128). "WWN does not exist in any proxy device Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 241
(1 through 128). "WWN configuration: switch:admin> 20:37:c3:11:71 22:00:00:20 :37:c3:1a:8a 10:00:00:00:c9:2b:6a:2c Slot f001 f002 f001 f002 f001 To persistently configure device WWN 00:11:22:33:44:55:66:77 to use slot f101h in fabric 5: switch in fabric 5: switch:admin> fcrproxyconfig -r - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 242
that are presented by FC Routers on the same backbone fabric as this FC Router. The default output displays only proxy device information relevant to this FC Router. Relevant proxy devices include proxy that are relevant to this FC Router 210 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 243
the specified port WWN. Examples To display the physical devices relevant to this FC Router: switch:admin> fcrphydevshow Device WWN Physical Exists PID in Fabric 2 10:00:00:00:c9:2b , fcrRouteShow, lsanZoneShow, switchShow Fabric OS Command Reference Manual 211 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 244
are not returned to the pool until the system reboots, because the phantom switch could still be accessible through other switches. Across a switch reboot, the allocation starts from the next usable WWN from the pool for the local FC Router: 212 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 245
2 switch:Admin> fcrresourceshow Daemon Limits: LSAN Zones: LSAN Devices: Proxy Device Slots: Max Allowed Currently Used 1000 22 10000 1208 10000 2 Phantom Node WWN: Phantom Port WWN: WWN Pool Size Allocated 8192 3790 32768 6446 Port Limits: Max proxy devices: 2000 Max - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 246
changed only when the specified port is disabled. Valid values for cost are 0, 1000 or 10000. Examples To display the cost of all EX_Ports: switch:admin> fcrrouterportcost Port Cost 7/3 1000 7/4 1000 7/9 1000 7/10 1000 7/16 10000 10/0 10000 To display the cost of one EX_Port - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 247
To set the cost of an EX_Port: switch:admin> fcrrouterportcost 7/10 10000 See Also switchShow, fcrRouteShow, portCfgEXPort fcrRouterPortCost 2 Fabric OS Command Reference Manual 215 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 248
creating a meta-SAN. There are FC are currently not supported, an NR_Port Switch in the Dest. Fabric The World Wide Name of the principal switch Switch in the Dest. Fabric 4 640000 1000 10:00:00:60:69:c0:05:d1 4 640100 1000 10:00:00:60:69:c0:05:d1 5 640200 1000 10:00:00:60:69:c0:20 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 249
saved. The principal switch attempts to provide 128) of the remote fabric represented by this translate domain. preferredDomainID Specifies the preferred domain ID (1 through 239) of the translate phantom. Examples To display the translate domain configuration: Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 250
translate domain created in fabric 2 that represents remote fabric 3 to a value of 8: switch:admin> fcrxlateconfig 2 3 8 xlate domain already configured, overwrite?(n) y To domain created in fabric 2 that represents remote fabric 3: switch:admin> fcrxlateconfig -r 2 3 xlate domain deleted See - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 251
Supported policies are Switch Connection Control (SCC), Device Connection Control (DCC) and Password (includes account database and password the fabric-wide policy to NULL (default) or no fabric-wide consistency, use the policy Set "". Supported policies are Switch Connection Control (SCC) and Device - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 252
to reject distribution of SCC and DCC policy sets: switch:admin> fddcfg --localreject "SCC;DCC" Local Switch Configured to reject policies. To set the Fabric-Wide Consistency Policy to "strict" for SCC and "tolerant" for DCC: switch:admin> fddcfg --fabwideset "SCC:S;DCC" See Also distribute 220 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 253
restrictions that may be in place. Operands none Examples To display the FDMI cache: switch:admin> fdmicacheshow Switch entry for domain 3 state: known version: v310 wwn: 10:00:00:60: of devices on the switch is 1 See Also fdmiShow Fabric OS Command Reference Manual 221 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 254
Examples To display FDMI information on a local switch: switch:admin> fdmishow Local HBA database contains: Supported Speed: 0x00000001 Port Speed: 0x00000001 Frame Size: 0x00000800 HBA attributes: Node Name: 20 **CT_TEST 1** Firmware Version: 03814101 OS Name and Version: Window 2000 Max CT Payload - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 255
" entries are not removed from the RNID database. Examples To clear the RLIR database: switch:user> ficonclear RLIR successfully clear local RLIR Database. To clear RNID database: switch:user> ficonclear RNID successfully clear not current entries from local RNID Database. See Also ficonHelp - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 256
for the switch: switch:admin> ficoncupset fmsmode enable fmsmode for the switch is now Enabled To set ASM bit in the mode register for the switch: switch:admin> ficoncupset modereg ASM 1 Active=Saved Mode bit is set to 1 See Also ficoncupshow 224 Fabric OS Command Reference Manual 53-1000436 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 257
the mode register bits are displayed. If a mode register bit is specified, then only the value of that bit is displayed. A value of 1 indicates that a given mode register bit is set, and 0 indicates that it is not set. Examples To display FMS mode for the switch: switch:user> ficoncupshow fmsmode - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 258
a list of FICON support commands, with descriptions. Operands none Examples To display a list of FICON commands: switch:admin> ficonhelp ficonclear Sets FICON-CUP parameters for a switch ficoncupshow Displays FICON-CUP parameters for a switch ficonhelp N/A ficonshow Displays contents of - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 259
named database that are local to the switch on which the command was issued. Flag values are as follows: 0x00 Indicates node ID of the storage port for RNID switch ID of the storage port for RNID switch for RLIR is not valid. 0x50 WWN card [unit number] Power Supply [unit number] Hardware - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 260
the individual switch. Link Incident Description Same as Link Incident Type. Link Incident Type Indicates the link incident type as one of the following: Bit-error- -4s including FCP and updates. 0x80 FC-4 support not specified. 0xa0 Reserved. 0xc0 Reserved. 228 Fabric OS Command Reference - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 261
; otherwise, an emulated control unit support only. 0x09 Reserved. 0x10 Switch, if it is a switch device; otherwise, reserved. 0x0b-0xff port number. Part Number Displays the switch chassis part number. PID Displays the 24-bit Fibre Channel port address in 0xDDAAPP Manual 229 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 262
RNID { {Fmt Type PID Registered Port WWN Registered Node WWN flag Parm 0x18 N 502b00 50:05:07:64:01:00:15:8d 50:05:07:64:00:c1:69:ca 0x10 0x200110 Type number: 002064 Model number: 101 Manufacturer: IBM Plant of Manufacture: 02 230 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 263
:05:07:64:01:40:0f:ca 50:05:07:64:00:c1:69 switch:admin> ficonshow LIRR fabric {Fmt Type PID Listener Port WWN Switch Port WWN Listener Type 0x18 N 502b00 50:05:07:64:01:00:15:8d 20 switch RNID database has 1 entries. To display the local RLIR database: switch :07:64:01:40:0f:ca 50:05:07:64:00:c1 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 264
05:07:64:01:00:15:8d } } {FRU Failure [3]: Power Supply[4] failure occurred on Mon Jan 13 12:11:38 2003 Fmt Protocol Domain Fabric WWN Switch WWN 0x18 07:64:01:00:15:8d } } } The Local ILIR database has 2 entries. See Also ficonClear 232 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 265
11 Zone A|B match and AL_PA match Discard Operands This command is supported only on Brocade 3250, 3850, 3900,12000, and 24000 platforms. The execution of operates. The port specified are relative to this slot number. The default is 0 and designed to operate on fixed-port-count products. - - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 266
program location to write DCAM test data in DCAM memory. The default value is 0. The maximum offset number is set if the specified number value is 0. The maximum offset number is set if the specified number is larger than the limit. Examples To run a frame filter test: switch Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 267
switches the primary partition (with the old firmware) to the secondary, and the secondary partition (with the new firmware) to the primary. The default (with new firmware) to the secondary and commits the new firmware to both version of the firmware: switch:admin> firmwarecommit Validating - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 268
. In single and dual-domain systems, this command by default downloads the firmware image to both CPs in rollover mode, to prevent disruption to application services. This operation depends on HA support. If HA is not available, you can still upgrade the CPs one at a time, using the -s option - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 269
a local directory, or if no password is required by the FTP server. This operand is required when accessing a SSH server. -p Specify the file transfer protocol used to download the firmware from the file server. Valid values are ftp and scp. The values are not case-sensitive. If -p is - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 270
: switch:admin> firmwaredownload Type of Firmware (FOS, SAS, or any application) [FOS]:SAS Target Slots (all, or slot numbers) [all]: Server Name or IP Address: 192.168.32.10 Network Protocol (1-auto-select, 2-FTP, 3-SCP) [1]: User Name: userfoo File Name: /home/userfoo/dist/release.plist Password - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 271
not have permission on host The password for the user is not specified correctly Indicated firmware does not exist on the host, or is not in the right format, or is corrupted The FTP or SSH service is not running on host Platform is not supported by the firmware indicated. For other return codes - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 272
Examples The following example shows the status of the firmwaredownload for an SAS image to the blades in slot 2 and 7. switch:admin> firmwaredownloadstatus [1]: Thu Jul 28 00:30:49 2005 Slot 2 (SAS): Firmware is being downloaded to the blade. It may take up to 30 minutes. [2]: Thu Jul 28 00:30:49 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 273
2 To display the status of a firmware download on a Brocade switch: switch:admin> firmwaredownloadstatus [1]: Fri Feb 15 22:17:03 2007 Firmware is being downloaded to the switch. This step may take up to 30 minutes. [2]: Fri Feb 15 22:20:54 2007 Firmware has been downloaded to the secondary - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 274
on active CP. [16]: Mon Dec 19 19:01:39 2005 Slot 5 (CP0, active): Firmwaredownload command has completed successfully. Use firmwareshow to verify the firmware versions. See Also firmwareCommit, firmwareDownload, firmwareRestore, firmwareShow 242 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 275
that may be in place. Operands none Examples To restore the former active firmware image: switch:admin> firmwarerestore Restore old image to be active ... Restore both primary and wait ... See Also firmwareCommit, firmwareDownload Fabric OS Command Reference Manual 243 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 276
of the storage device. Operands none Examples To display the firmware versions in a Brocade director with FA4-18 blades installed in slot 2 and 7. switch:admin> firmwareshow Slot Name Appl Primary/Secondary Versions Status 2 FA4-16 FOS v5.3.0 v5.3.0 SAS v3.0.0 v3.0.0 DMM v3.0.0 v3 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 277
switch by sending ELS Echo frames from the switch F_Port transmitter and receiving ELS is, a short wavelength SFP (switch) port is connected to another running. This command is supported only on Brocade 200E, 3250, 3850, default of 10 is used. This operand is optional. Fabric OS Command - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 278
values are: 0 CSPAT (default) 1 BYTE_LFST 2 CHALF_SQ 3 QUAD_NOT 4 CQRT_SQ 5 CRPAT 6 RANDOM All other values are modularized into one of these values is omitted, the default value is 512. This operand is optional. Examples To run fportTest on a switch: switch:admin> fporttest -ports Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 279
STATS STATS_C3FRX STATS_FRX STATS_FTX TIMEOUT XMIT Refer to the Fabric OS Message Reference for more information. itemList, loopPortTest, portTest, spinFab fportTest 2 Fabric OS Command Reference Manual 247 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 280
This command has the following operands: --enable feature Enables a feature on the switch. Valid values for feature are: fcr The FC Routing service will be enabled on this switch. The FC Routing service is by default disabled on a new switch with Fabric OS v5.2. Use fosConfig --show to determine the - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 281
can be run while the switch state is "online". iSNSC The iSNSC service will be disabled on this switch. This command can be run while the switch state is "online". Displays the current operating status of features on the switch. The features shown here may not be supported on all platforms. If you - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 282
guide supported value, specifying the replacement of the WWN card. Examples To replace the World Wide Name card: switch power cycle, or CP failover, please follow the recovery procedure in Core Switch and follow the instructions to complete the operation please wait about 20 seconds to complete - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 283
of the local switch is currently confirmed. Bit map of all the ISL. Bit positions correspond to the default areas of the ports. Bit 0 refers to default area of the switch, bit 1 refers to default area 1, and so forth. Bit map of all the trunk slave ports. Bit map of all the Fx_Ports. Bit map of all - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 284
= 0x1003e630 agingTID = 0x1004ca28 agingTo = 10000 lsrDlyTID = 0x100507a8 lsrDelayTo = 5000 lsrDelayCount = 1 ddb_sem = 0x1003e6e8 fabP: event_sch = 0x0 See Also bcastShow, topologyShow, uRouteShow 252 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 285
to disable the alarms. If no operand is specified, the default value is 0 (alarms deactivated). This operand is optional. Examples To enable alarms in Fabric Watch: switch:admin> fwalarmsfilterset FW: Alarms are already disabled switch:admin> fwalarmsfilterset 1 FW: Alarms are aleady enabled See - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 286
Domain restrictions that may be in place. Operands none Examples To display the status of alarm filtering in Fabric Watch: switch:user> fwalarmsfiltershow FW: Alarms are enabled switch:user> fwalarmsfiltershow FW: Alarms are disabled See Also fwAlarmsFilterSet 254 Fabric OS Command Reference - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 287
subject to Admin Domain restrictions that may be in place. Operands none Examples To initialize all classes under Fabric Watch: switch:admin> fwclassinit fwClassInit: Fabric Watch is updating... fwClassInit: Fabric Watch has been updated. See Also fwConfigReload, fwConfigure, fwShow Fabric OS - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 288
Admin Domain restrictions that may be in place. Operands none Examples To reload the saved Fabric Watch configuration: switch:admin> fwconfigreload fwConfigReload: Fabric Watch configuration reloaded See Also configDownload, configUpload, fwClassInit, fwConfigure, fwShow 256 Fabric OS Command - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 289
and modify threshold information for the Fabric Watch configuration. Switch elements monitored by Fabric Watch are divided into classes, Fabric Watch license. Not all platforms support fans or power supplies. If you attempt to configure values for these items, an "ERROR: Manual 257 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 290
TS Out of Sync No-FCS Incompatible Security DB Illegal Command Flash The execution of this command is subject to Admin Domain supported. F/FL Port (Copper) class is supported only on Embedded platforms. .. TABLE 12 Class Access Gateway Mode Area Environmental SFP Port Temperature Fan* Power - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 291
Flash area Invalid CRCS RX Performance TX Performance Customer Defined Flash Not all platforms support fans or power supplies. If you attempt to configure values configure thresholds in Fabric OS mode: switch:admin> fwconfigure 1 : Environment class 2 : Fan 3 : Power Supply 4 : return to previous - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 292
2000 0 C Informative 1 : refresh 2 : disable a threshold 3 : enable a threshold 4 : advanced configuration 5 : return to previous page Select choice => : (1..5) [5] switch choice => : (1..5) [5] 5 See Also fwClassInit, fwConfigReload, fwShow 260 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 293
, the configuration prompt displays. Examples To change FRU state alert configuration: switch:admin> fwfrucfg The current FRU configuration: Alarm State Alarm Action Slot 0 1 Power Supply 0 0 Fan 0 0 WWN 0 0 Note that the value 0 for a parameter means that it is NOT used in the - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 294
fwSetToDefault Set boundary & alarm level to default fwShow Show thresholds monitored or port persistence time sensorShow Show sensor readings switchStatusPolicySet Set switch status policy parameters switchStatusPolicyShow Show switch status policy parameters switchStatusShow Show overall - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 295
or modify the configuration and status of the Fabric Watch email alert in the switch. Switch elements monitored by Fabric Watch are divided into classes, and email alerts are based Disable Email Alert 3 : Enable Email Alert 4 : Send Test Mail Fabric OS Command Reference Manual 263 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 296
an item => : (0..13) [11] 1 Mail To: [NONE] [email protected] Email Alert configuration succeeded! See Also dnsConfig, fwConfigure, ipAddrSet, ipAddrShow 264 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 297
out of specification SRX SFP receive power is out of specification STX SFP transmit power is out of specification SCU SFP requires a Fabric Watch license. NOTE Port errors are not supported for virtual ports and SFP errors are not applicable for Command Reference Manual 265 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 298
a port detailed report: switch:user> fwportdetailshow --s h Port Detail Report Switch Name: switch IP address: 192.168.163.237 Port Exception report [by Healthy] Report time: 05/21/2007 11:22:58 PM --------Port-Errors SFP-Errors---- 266 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 299
fwPortDetailShow 2 See Also Port# Type State Dur(H:M) LFA LSY LSI PER INW CRC PSC BLP STM SRX STX SCU SVO 001 F HEALTHY 409:09 014 F HEALTHY 409:09 015 E HEALTHY 409:09 switchStatusShow Fabric OS Command Reference Manual 267 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 300
switch this command is allowed only if the local switch is a member of the current Admin Domain. summary information on an eight port switch: switch:user> fwsamshow Port# Type Total U_PORT 0 0 0 100 3 E_PORT 21 0 0 78 4 E_PORT 20 0 0 80 5 U_PORT 0 0 0 100 6 U_PORT 0 0 0 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 301
period in which a port must be persistently in a state before being actually being recognized as such. Examples To set message levels and port persistence time: switch:user> fwset --port --persistence 18 See Also fwShow Fabric OS Command Reference - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 302
Use this command to set boundary and alarm levels to custom values for all classes and areas in Fabric Watch. This command requires Operands none Examples To set alarm levels to custom values: switch:admin> fwsettocustom Committing configuration...done. See Also fwSetToDefault 270 Fabric OS - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 303
levels to the default values. Synopsis fwsettodefault Description Use this command to return boundary and alarm levels to defaults for all classes none Examples To return alarm levels to default values: switch:admin> fwsettodefault Committing configuration...done. See Also fwSetToCustom Fabric - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 304
class thresholds are supported. F/FL Port (Copper) class threshold is supported only on Embedded platforms . Examples To display thresholds and port persistence time: switch:user> fwshow 1 : Show class thresholds 2 : continued on next page) 272 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 305
value envFan001 Env Fan 1 2576 RPM envFan002 Env Fan 2 2518 RPM envFan003 Env Fan 3 2481 RPM switch 10:50:21 on 02/01/2000 Lower bound: Upper bound: Buffer Size: 0 C 75 C 10 Value history: 33 C Disabled? 16:30:17 on 12/09/2011 Fabric OS Command Reference Manual 273 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 306
page) Event 1 occurred 10 times, last at 16:49:02 on 12/09/2011 * Event 5 occurred 1 time, last at 16:30:23 on 12/09/2011 Callbacks: No callbacks are registered. switch:admin> fwshow --port --persistence FW: current port persistence time = 18s switch:user> fwShow --disable --port Port Threshold - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 307
to the UNIX Korn shell history facility. The h command displays the 20 most recent commands typed into the shell; the oldest commands are replaced commands: switch:admin> h 1 version 2 switchshow 3 portdisable 2 4 portenable 2 5 switchshow See Also none Fabric OS Command Reference Manual 275 53 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 308
Description Use this command to disable the High Availability feature in the switch. If the HA feature is already disabled, this command does nothing none Examples To disable the High Availability feature: switch:admin> hadisable HA is disabled See Also haEnable 276 Fabric OS Command Reference - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 309
High Availability feature in the switch. This command displays the health diagnostic has discovered a problem with the blade. The Channel addresses configured for the switch. Additional internal HA state information about the High Availability feature status: switch:admin> hadump Local CP (Slot 6, - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 310
32.224.1 CP1 Ethernet IP Address: 10.32.227.67 Ethernet Subnetmask: 255.255.240.0 Host Name: cp1 Gateway IP Address: 10.32.224.1 Slot 10 eth0: 10.32.227.69/20 Gateway: 10.32 :64:260:69ff:fee4:3a/64 cp 0 static fec0:60:69bc:64:205:1eff:fe25:9c1/64 cp 1 static fec0:60:69bc:64:205:1eff:fe02:a197/64 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 311
Description Use this command to enable the High Availability feature in the switch. If the HA feature is already enabled, this command does nothing. To enable the High Availability feature in the switch: switch:admin> haenable HA is enabled See Also haDisable Fabric OS Command Reference - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 312
and the CPs are in sync, the port traffic light does not flash during the failover, even while traffic is continuing to flow. In an command is allowed only if the local switch is a member of the current Admin Domain. This command is supported only on systems with dual -CP Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 313
problem be supported on non switch:admin> hashow Local CP (Slot 6, CP1): Active, Warm Recovered Remote CP (Slot 5, CP0): Standby, Failed Backplane PCI fail, severity: CRITICAL HA enabled, Heartbeat Up, HA State not in sync See Also haDisable, haEnable, haFailover Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 314
synchronization. The execution of this command is subject to Admin Domain restrictions that may be in place. Examples To enable the HA state synchronization: switch:admin> hasyncstart HA State synchronization has started See Also haFailover, haShow, haSyncStop 282 Fabric OS Command Reference - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 315
execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To disable the HA state synchronizing process: switch:admin> hasyncstop See Also haFailover, haShow, haSyncStart Fabric OS Command Reference Manual 283 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 316
current user; this can vary, according to: Login user role License key Switch model To access help information for a specific command, enter the command optional. Examples To display help information for the help command: switch:admin> help help See Also diagHelp, fwHelp, licenseHelp, perfHelp - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 317
insertion and removal events for blades, power supplies, fans, and World Wide Cards data sets: Object type FAN, POWER SUPPLY, and one CP switches. Object number Slot number for blades the late FRU insertion or removal event: switch:admin> historylastshow POWER SUPPLY Unit 2 Inserted at Tue Aug - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 318
operands: rot Rotating mode. fi Log is filled once, then new entries are discarded. Examples To change the history mode to first-in from rotating: switch:admin> historymode History Mode is: Rotating. See Also historyLastShow, historyShow 286 Fabric OS Command Reference - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 319
or Unknown Brocade directors support 100 history log entries; all other platforms, which contain FRUs, support 28 entries switch:admin> historyshow FAN Unit 3 Removed at Tue Aug 14 10:05:37 1970 Factory Part Number: 20-123456-12 Factory Serial Number: 1013456800 POWER Manual 287 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 320
Serial Number: 1013456800 CP BLADE Slot 6 Inserted at Tue Aug 14 13:59:50 2001 Factory Part Number: 60-0001604-02 Factory Serial Number: FP00X600128 POWER SUPPLY Unit 2 Inserted at Tue Aug 14 15:52:10 2001 Factory Part Number: 60-0001536-02 Factory Serial Number: 1013456800 Records: 11 See - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 321
Use this command to display the version of the Java plug-in supported by Web Tools. This command also displays the URL from which the Operands none Examples To display the Java plug-in version: switch:admin> httpcfgshow Current HTTP configuration javaplugin.version = 1,3,1 javaplugin.homeURL - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 322
did not exec SUPERPRIV 100 used super-user privileges DUMPCORE 200 dumped core SIGNALED 400 killed by a signal S Process state codes: D number of the process; higher numbers mean lower priority NI Nice value used in priority computation ADDR Memory address of the process SZ The - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 323
the following operand: processID Specifies the process name or process ID for the process to display. Examples To display information about process ID 433: switch:admin> i 433 F S UID PID PPID C PRI NI ADDR SZ WCHAN TTY TIME CMD 000 S 0 433 1 0 69 0 - 1283 5c64 ? 00:00:02 fabricd See Also - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 324
is not supported on Brocade 3016 switches. The supported by the network equipment to which it is attached may result in an inability to communicate with the system through its ethernet interface. It is recommended that you only use this command from the 292 Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 325
to 10 Mbit/sec half-duplex operation, when entering this command through the serial console port: switch:admin> ifmodeset eth0 Auto-negotiate (yes, y, no, n): [yes] n Force 100 Mbps [no] y Committing configuration...done. See Also ifModeShow Fabric OS Command Reference Manual 293 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 326
eth0, where eth is the network interface and 0 is the physical unit. Examples To display the link operating mode for the "eth0" Ethernet interface: switch:admin> ifmodeshow eth0 Link mode: negotiated 100baseTx-HD, link ok MAC Address: 00:60:69:D0:24:40 See Also ifModeSet 294 Fabric OS Command - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 327
port is a part. defaultCost Default cost of sending a frame value of 1000 indicates a 1-Gb/sec link. A value of 500 indicates a 2-Gb switch. idbNo IDB number. Should be equal to port_number. remPort Port number on the remote switch connected to this port. Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 328
. It is used to transmit topology information to the neighbor switch. If no acknowledgement is received within this value, the frame is retransmitted. nCmdAcc Total number of commands accepted from the neighbor switch. Number includes Hellos, Link State Updates (LSU), and LSAs. nInvCmd - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 329
interface information: switch:user> interfaceshow 1/4 idbP = 0x1008b3d0 Interface 4 data structure: nghbP ifNo masterPort defaultCost cost delay lastScn lastScnTime upCount lastUpTime downCount lastDownTime downReason iState = 0x1008c668 = 4 = 4 (self) = 500 = 500 = 1 = 16 = Apr 02 20:01:44 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 330
2 interfaceShow rXmitTo nCmdAcc nInvCmd nHloIn nInvHlo nLsuIn nLsaIn attHloOut nHloOut attLsuOut nLsuOut attLsaOut nLsaOut = 5000 = 7 = 0 = 2 = 0 = 2 = 3 = 2 = 2 = 3 = 3 = 2 = 2 See Also nbrStateShow, portShow, switchShow 298 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 331
mode is disabled, configuration parameters are returned to their default states and can be changed using configure. Only Port World Wide Name zoning is supported in interoperability mode. FC Routing services are not available in interop mode. Switches connected to edge fabrics are not available in - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 332
[no] Note: It is recommended that you reboot this switch for the new change to take effect. switch:admin> reboot To see connections on a switch that is operating in interop mode (ports 8/0, 8/1 show the connections to the Brocade fabric; ports 8/2, 8/3 show the connections to a legacy McDATA fabric - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 333
94 8 14 045e00 id N2 No_Light 95 8 15 045f00 id N2 No_Light 208 8 16 04d000 -- -- Offline Disabled (Persistent) 209 8 17 04d100 -- -- Offline Disabled ( 211 8 19 04d300 -- -- Offline Disabled (Persistent) 212 8 20 04d400 -- -- Offline Disabled (Persistent) [output truncated] 223 8 31 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 334
Use this command to turn off the IOD option. The IOD option is turned off by default; however, if the IOD option was turned on using iodSet, this command can be Examples To turn off the IOD option: switch:admin> iodreset switch:admin> iodshow IOD is not set See Also iodSet, iodShow 302 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 335
delivered in order, even when the traffic between switches is shared among multiple paths. However, when topology out-of-order, even during fabric topology changes. The default behavior is for the IOD option to be off. switch:admin> iodset switch:admin> iodshow IOD is set See Also - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 336
Use this command to display whether the IOD option is enabled or disabled. Operands none Examples To display the current setting of the IOD option: switch:admin> iodshow IOD is not set See Also iodReset, iodSet 304 Fabric OS Command Reference - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 337
CP IP address use -cp; to set the switch IP address use -sw. When setting the switch, the command prompts for the Ethernet IP address, address is ignored. On a chassis based system with intelligent blades the values for the blade in slot n can be set from the command line Manual 305 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 338
of logical switch 0. 1 of logical switch 1. Sets switch or CP: switch:admin> ipaddrset -ipv6 -cp 0--add 1080::8:800:200C:417A/64 IP address is being changed...Done. See Also To set the IP address details for switch number 1 on a chassis-based system: switch based system: switch:admin> ipaddrset - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 339
To display the IP address for logical switch 0: switch:admin> ipaddrshow -sw 0 Ethernet IP Address: 192.168.166.147 Ethernet Subnetmask: 255.255.255.0 Fibre Channel IP Address: 0.0.0.0 Fibre Channel Subnetmask: 0.0.0.0 See Also ipAddrSet Fabric OS Command Reference Manual 307 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 340
policy name is a unique string composed of maximum 20 alpha, numeric or underscore characters. The default_ipv4 and default_ipv6 names are reserved for default IP filter policies. The policy name is case insensitive to persistent configuration. 308 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 341
the same type. Activating the default IP filter policies will return the IP management interface to its default state. An IP filter the address must be a 32 bit address in dot notation, or a CIDR style IPv4 prefix. For IPv6 filter type, the address must be in a 128 bit IPv6 address in any format - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 342
, or a service name. -proto specific policy with an IPv4 address: switch:admin> ipfilter --create ex1 - port number, and to permit the rule: switch:admin> ipfilter --addrule ex1 -sip 192.168 IP filter policy for a specify IP policy and type: Switch:admin> ipfilter --show ex1 Name: ex1, Type: ipv4 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 343
iscsicfg --clear initiator [-h ] iscsicfg --show initiator [-i initiator_name] [-h ] iscsicfg --abort transaction -x transaction_id [-h ] iscsicfg --show transaction [-h ] iscsicfg --clear all [-h ] iscsicfg --commit all [-f ] [-h ] Fabric OS Command Reference Manual 53-1000436-01 iscsiCfg 2 311 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 344
. This triggers the propagation of changes to all iSCSI-enabled switches and blades in the fabric. Changes will not take effect [-h ] Associates the authentication method auth_method with the target. Valid values for auth_method are CHAP and none. If CHAP is specified, Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 345
iscsiCfg 2 lun dd ddset Fabric OS Command Reference Manual 53-1000436-01 --delete tgt -t target_name [-h ] Deletes format. Currently, only IQN format is supported. Multiple entities may be specified as a comma-separated list. The IQN may be a maximum of 64 characters. --add dd -d dd_name -m - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 346
To create a CHAP entry: switch:admin> iscsicfg --create auth -u user1 -s abcdefg123 The operation completed successfully. To modify a CHAP entry associated with an existing user: switch:admin> iscsicfg --modify auth -u user1 -s newsecret 314 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 347
Name: State/Status: iqn.2005-10.com.brocade.tgt1 Offline/Defined Name: State/Status: iqn.2222-23.com.brocade:21:00:00:20:37:df:83:fc Online/Committed To delete a target entry: switch:admin> iscsicfg --delete tgt -t iqn.2005-10.com.brocade.tgt1 The operation completed successfully. To clear the - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 348
20:37:df:83:fc iqn.2002-12.com.brocade:21:00:00:20:37:df:83:fc Operation Succeeded To add a LUN map: switch:admin> iscsicfg --add lun -t iqn.2005-10.com.brocade.tgt1 -w 22:00:00:04:cf:20:5d:33 -l 0:0 The operation completed successfully. switch and members: switch:admin> iscsicfg : switch:admin - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 349
that attempted to login: switch:admin> iscsicfg --show initiator Number of records found: 1 Name iqn.1991-05.com.brocade:initiator1 IP Address 172.16.14.101 switch:admin> iscsicfg --show initiator -i iqn.1991-05.com.brocade:initiator1 Fabric OS Command Reference Manual 317 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 350
:50:06:0e:80:00:43:80:a2 iqn.2222-23.com.brocade:21:00:00:20:37:df:83:fc To display all targets that are accessible by a specified initiator switch:admin> iscsicfg --show initiator -i iqn.1991-05.com.brocade:initiator1 The operation completed successfully. Index iSCSI Name IP Address Type - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 351
run. By default, the command runs all tests. Valid values are: 0 switch:admin> iscsichiptest --slot 7 -unit 1 -testtype 0 Running iscsichiptest Test Complete: iscsichiptest Pass 1 of 1 Duration 0 hr, 3 min & 12 sec (0:3:12:511). passed. See Also iscsiPathTest Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 352
ge, --default /ge --show /ge [-v] --modify /ge Description Use this command to display a list of iSCSI support commands, with -m -s isnsccfg --reregister isnsccfg --show 320 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 353
the list of iSCSI support commands: switch:admin> iscsihelp fclunquery Display a list of LUNs of FC target(s). fosconfig Enable/disable FabOS services iscsicfg Manage/display all iscsi /arp entries on the GigE Port See Also switchShow Fabric OS Command Reference Manual 321 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 354
to loopback at network processor 8-bit FIFO. -nframes count Specifies the number of frames to send. The test will progress until the specified number of frames has been transmitted on each port. The default value is 100. Examples To run iscsipathtest: switch:admin> iscsipathtest --slot 2 -path - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 355
default iSCSI port settings. Setting Default Error recovery level 0 Connections per session 1 Data digest support Disabled Header digest suppor Disabled Immediate data support No First burst length value slot Specifies the slot number. Fabric OS Command Reference Manual 323 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 356
supports FC4-16IP blades in Brocade 48000 directors. geport -h Specifies the port number of a GbE port to be configured in the specified slot. Use -h on any option to display the help text for it. Examples To modify the port parameters: switch Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 357
.1991-05.com.microsoft:win-iscsi.lab iqn.2002-12.com.tgt:21:00:00:04:cf:5d:cf:0e 0x400001370000 Fabric OS Command Reference Manual 325 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 358
Target Information Index FC WWN 1 2f:df:00:06:2b:0d:10:b9 iSCSI Operating Login Parameters: Session Level Parameter Name Self Value Peer Value Max. Burst Length 256KB 256KB First Burst Length 512B 64KB Max outstanding R2T 1 16 326 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 359
to retain Default time to wait Error recovery level Initial R2T 20s 2s 0 Off iSCSI Operating Login Parameters: Connection Level Connection Index: 1 Parameter Name Self Value Value Max. , iscsiPortCfg 60s 0s 2 Off Peer 64KB On On On Fabric OS Command Reference Manual 327 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 360
To display a target name prefix: switch:admin> iscsiswcfg --showgw Target name is: iqn.2002-12.com.brocade To change a target name prefix: switch:admin> iscsiswcfg --modifygw -t iqn.2002-10.com.brocade The operation completed successfully. 328 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 361
See Also fosConfig, iscsiCfg, iscsiPortCfg iscsiswcfg 2 Fabric OS Command Reference Manual 329 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 362
names. The default prefix is iqn.2002-12.com.brocade. The execution brocade To change the target name prefix: switch:admin> iscsitargetname --modify -u iqn.2002-10.com.brocade The operation completed successfully See Also fosConfig, iscsiCfg, iscsiPortCfg 330 Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 363
on this switch. The node WWN, domain ID, and switch name to which Operands none Examples To display the ISL connections for the switch: switch:user> islshow 1: 33-> 29 10:00:00: TRUNK 6:162->160 10:00:00:60:69:e2:09:fa 7:208-> 16 10:00:00:05:1e:37:02:73 3 Termonator8 4 Dazzler_1 15 Stealth_05 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 364
supports Brocade FC4-16IP blades in Brocade 48000 directors . --s server_ip Specifies the IP address in dotted-decimal form. Examples To set the IP address of the iSNS server (GbE port attached): switch Management port attached) switch:admin> isnsccfg --set switch:admin - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 365
isnscCfg 2 See Also Initiated re-register of iSNS objects with iSNS server To clear the IP address of iSNS server: switch:admin> isnsccfg --clear Cleared iSNS server configuration. none Fabric OS Command Reference Manual 333 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 366
a smaller set, the parameter value is an item list with the 16-port/blade system. On that same system, "1/0, 16, 32" is not a valid list: even though it is legal syntax, the ports do not exist. If no slot number is specified, all lists except user port lists will use the default Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 367
higher-level tests, such as spinSilk to specify which user-accessible external ports within the current switch (selected during telnet login) are tested. When specified in an item list, user ports might , portRegTest, spinSilk, sramRetentionTest Fabric OS Command Reference Manual 335 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 368
. Examples To terminate an open telnet connection: switch:admin> killtelnet Collecting login information....Done List of .168.130.29 " since " 6:29pm" and has been inactive for "16.00s ", the current command executed being: "-rbash ". The device entry is Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 369
switch and the fabric to which it is connected are optional, licensed products. Without a license installed for such products, their services are not available. A license key is a string of approximately 16 is added to the switch. For a trunking license portEnable or the switch must be refreshed - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 370
:admin> licensehelp licenseAdd licenseIdShow licenseRemove licenseShow Add a license to this switch Show system license ID Remove a license from this switch Show current licenses See Also licenseAdd, licenseIdShow, licenseRemove, licenseShow 338 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 371
switch and the fabric are optional, licensed products. Without a license installed for such products, the services eight pairs of hexadecimal values, separated by colons. Each hexadecimal value is between 00 (0) and Examples To display the license ID: switch:admin> licenseidshow a4:f8:69:33: - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 372
can support. Operands This command has the following operands: --release portnumber Releases a license assignment from a port when the switch is on Demand license assignments: sw5:admin> licensePort -show 20 ports are available in this switch 1 POD license is installed Dynamic POD method is - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 373
2 5 ports are assigned to the first POD license Ports assigned to the base switch license: 0, 1, 2, 3, 4, 5, 6, 7, 15, 16 Ports assigned to the first POD license: 8, 9, 17, 18, 19 Ports Also licenseAdd, licenseRemove, licenseShow, licenseHelp Fabric OS Command Reference Manual 341 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 374
to remove an existing license key from a switch. The existing license key must be entered exactly product uninstalled. After removing a license key, the switch must be rebooted. With no license key, licenseShow a license key from the switch: switch:admin> licenseremove "bQebzbRdScRfc0iK" removing - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 375
of licensed products enabled by these keys. The message "No license installed on this switch" is displayed when no licenses are installed. The execution of this command is To display the installed license keys on a switch: switch:admin> licenseshow bQebzbRdScRfc0iK: Web license Zoning license - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 376
switch and a destination switch 16 lists the link cost defaults. TABLE 16 Link Cost Defaults Link type Link cost - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 377
this port will then revert to its default link cost. This operand is optional. 2000 (STATIC) 2 12 1000 2 13 1000 2 14 1000 2 15 1000 Type to continue, Q to stop: switch:admin> linkcost 2/4 500 switch:admin> linkcost 2/4 Interface2/4 Cost switch:admin> linkcost 2/4 0 switch - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 378
you to access commands that you cannot access at your current user level. Operands none Examples To log in as admin from the login user: switch:user> login login: admin Password:xxxxxx See Also logout 346 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 379
command is accepted as a synonym for logout, as is Ctrl-D at the beginning of a line. Operands none Examples To log out from an rlogin session: switch:admin> logout See Also login Fabric OS Command Reference Manual 347 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 380
switch all the switch components, from the main board, a short wavelength SFPed (switch) port is connected to counters are stuck at some value. Check if the number of support only. This command is supported only on Brocade default value is 10. The maximum value is 2,147,483,647, - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 381
pattern. Valid values include: 1 byte (default) 2 word 4 quad This operand is optional. Examples To perform a loopback port test: switch:admin> loopporttest , cmiTest, itemList, portLoopbackTest, portRegTest, spinSilk, sramRetentionTest Fabric OS Command Reference Manual 349 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 382
Displays logical SAN zone information. in the zone) is provided for each LSAN zone. The default output displays only WWNs of the zone members. Search parameters -f switch which can be different than the database stored on the other FCR switches. 350 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 383
:55 Fabric ID: 5 Zone Name: lsan_fcr11_0 10:00:00:00:c9:2b:6a:68 21:00:00:20:37:18:22:55 50:05:07:65:05:84:0b:83 50:05:07:65:05:84:09:0e switch# fcrFabricShow, fcrPhyDevShow, fcrProxyDevShow, fcrRouteShow, switchShow Fabric OS Command Reference Manual 351 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 384
database entry, which is permanently allocated. The link state record (LSR), which is allocated when a switch is connected to the fabric. The LSR describes the links between connected domains in a fabric. For identical to the domain number. 352 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 385
switch on the other side of the link. Port number on the local switch. Port number of the port on the other side of the link. Cost of this link. The default cost : Link State Record pointer = 0x10053d18 lsAge = 16 reserved = 0 type = 1 Fabric OS Command Reference Manual 353 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 386
= 16, flags = 0x0 LinkId = 2, out port = 16, rem = 27, rem port = LinkId = 2, out port = 32, rem port = LinkId = 2, out port = 33, rem switch has sixteen links in NB_ST_FULL state, all of them are connected to switch 2. See Also interfaceShow, nbrStateShow 354 Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 387
total used Mem: 129740800 112562176 Swap: 0 0 switch:admin> memshow -m total used Mem: 123 107 Swap: 0 0 free 17178624 0 free 16 0 shared 0 buffers cached 139264 30396416 shared 0 buffers 0 cached 28 See Also saveCore Fabric OS Command Reference Manual 355 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 388
used for the four frames, one pattern each: 1000 bytes of CSPAT 480 bytes of RDRAM_PAT 2112 bytes of BYTE_LFSR 356 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 389
be used to determine which components of the switch are faulty. Operands The following operands are optional the specified number of frames has been transmitted on each port. The default value for count is 1, so the total number of frames sent will be OS Command Reference Manual 357 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 390
a list of blade ports to test. By default, all the blade ports in the specified slot 16-31 ASIC-pair 2: -ports 32-47 ASIC-pair 3: -ports 48-63 To run a functional test on slot 1 using external (SERDES) loopback: switch : minicycle Pass 1 of 1 358 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 391
functional test on ports 0, 1, 2, and 8 using port loopback: switch:admin> minicycle -ports 0,1,2,8 -lb_mode 1 Back Plane Loop Back mode is ON. Running mini Cycle One moment please ... Path 0 ... Spinning ... Path 1 ... skipped RXQ_RAM_PERR Fabric OS Command Reference Manual 359 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 392
the Fabric OS Message Reference for more information. See Also backport, camTest, centralMemoryTest, cmemRetentionTest, cmiTest, itemList, portLoopbackTest, portRegTest, spinSilk, sramRetentionTest 360 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 393
default is 0 and designed to operate on fixed-port-count products. Examples To display all index 1 ASIC pair properties: switch:user> minispropshow 1 -all slot: 1, miniS: 0 [2/16 : 2 [2/16] (be,17) (be,16) (be, 16] (be,23) (be,22) (be,21) (be,20 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 394
: Switch WWN 10:00:00:60:69:20:15:71 10:00:00:60:69:00:30:05 Capability Name 0x0000008f "switch1"* 0x0000008f "switch2" Capability Bit Definitions: Bit 0: Basic Config Service Supported. Bit 1: Platform Management Service Supported. Bit 2: Topology Discovery Service Supported. Bit 3: Unzoned - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 395
to configure the MS ACL. MS allows a SAN management application to retrieve and administer the fabric and interconnect elements, such as switches. This application is located at the Fibre Channel well-known address, 0xFFFFFA. If the MS ACL is empty (default), MS is available to all systems connected - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 396
2 msConfigure done ... See Also msCapabilityShow, msPlatShow, msPlClearDB, msPlMgmtActivate, msPlMgmtDeactivate, msTdDisable, msTdEnable, msTdReadConfig, secPolicyShow 364 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 397
Examples To display the MS platform database for a fabric: switch:admin> msplatshow Platform Name: [9] "first obj" Platform Node Names: 1 Associated Node Names: 10:00:00:60:69:20:15:71 Platform Name: [10] "second obj" Platform Type: 10:00:00:60:69:20:15:79 10:00:00:60:69:20:15:75 See Also - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 398
in place. Operands none Examples To display the MS platform service database control block: switch:admin> msplatshowdbcb Domain Worldwide Name Retry Count Exchange Status msPlatShow, msPlClearDB, msPlMgmtActivate, msPlMgmtDeactivate 366 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 399
platform database on all switches in the fabric. Because be issued only from the primary FCS switch. The execution of this command is subject switch:admin> msplcleardb MS Platform Service is currently enabled. This will erase MS Platform Service clearing MS Platform Service Database!! See Also - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 400
in the fabric boot with the MS platform service enabled. By default, the MS platform service is disabled. Before issuing, run the msCapabilityShow command to verify all switches in the fabric support MS platform service; otherwise, the command fails. When security is enabled, this command can - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 401
entire fabric. This command deactivates the MS platform service for each switch in the fabric and commits the change to nonvolatile storage. When security is enabled, this command can be issued only from the primary FCS switch. This command is supported only in AD0 and AD255 contexts. The execution - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 402
across power cycles and reboots. If the "ALL" operand is used, this command attempts to disable the topology discovery service on all switches in the fabric. When security is enabled, and using the "ALL" operand, this command can be issued only from the primary FCS switch. This command is supported - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 403
. Limitations Topology Discovery Management requires the attached devices which include attached switches to support RNID ELS. Operands This command has the following operand: "ALL" Enables the MS topology discovery service throughout the entire fabric. This operand is optional. Examples To - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 404
restrictions that may be in place. Operands none Examples To display the status of the topology discovery service: switch:admin> mstdreadconfig *MS Topology Discovery is enabled. See Also msCapabilityShow, msConfigure, msPlMgmtActivate, msPlMgmtDeactivate, msTdDisable, msTdEnable 372 Fabric - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 405
the login session details. The login session gives details of the following: CP/switch (or console/serial port) used to log in The IP address of the Examples To display current login information: switch:admin> myid Current Switch: switch Session Detail: switch (123.123.123.123) Active Redundant - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 406
are displayed. Examples To display information about switches directly connected to the local switch: switch:user> nbrstateshow 2/0 Local Domain ID: 1 Local Port Domain Remote Port State 16 2 48 NB_ST_FULL See Also interfaceShow 374 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 407
nCmdAcc nInvCmd nHloIn nInvHlo nLsuIn nLsaIn attHloOut nHloOut attLsuOut nLsuOut attLsaOut nLsaOut = 37 = 0 = 10 = 0 = 17 = 10 = 11 = 11 = 12 = 12 = 17 = 17 switch:admin> nbrstatsclear 1/0 switch:admin> interfaceshow 1/0 idbP = 0x10050a38 Fabric OS Command Reference Manual 375 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 408
= 500 (output truncated) nCmdAcc = 0 nInvCmd = 0 nHloIn = 0 nInvHlo = 0 nLsuIn = 0 nLsaIn = 0 attHloOut = 0 nHloOut = 0 attLsuOut = 0 nLsuOut = 0 attLsaOut = 0 nLsaOut = 0 See Also interfaceShow, portShow, switchShow 376 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 409
:cf:9f:7d:e0 Device type: Physical Target Port Index: 20 Share Area: No Device Shared in Other AD: No Aliases: a320 (continued on next page) NL 0314d4; 3;22:00:00:04:cf:9f:26:7e;20:00:00:04:cf:9f:26:7e; 0 Fabric OS Command Reference Manual 377 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 410
20:00:00:e0:8b:01:ce:d3": switch:user> nodefind 20:00:00:e0:8b:01:ce:d3 Remote: Type Pid COS PortName NodeName NL 020eef; 3;20:00:00:e0:8b:01:ce:d3;20 : switch:user> nodefind abcd No device found. See Also aliShow, nsAllShow, nscamShow, nsShow 378 Fabric OS Command Reference Manual 53-1000436 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 411
. This value indicates what type of registered state change notification (RSCN) a device registers to receive. Values include: to the switch Virtual Contrived device by the switch NPV Device connected to the Nx_Port, using FDISC to log in to the switch iSCSIDevice Manual 379 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 412
:02:d6;20:00:00:60:69:00:02:d6; na Fabric Port Name: 20:03:00: switch:admin> nsaliasshow -r { Type Pid COS PortName NodeName SCR N 021200; 2,3;10:00:00:60:69:00:03:19;30:00:00:60:69:00:03:19; 3 FC4s: FCIP Fabric Port Name: 20 :00:02:d6;20:00:00:60:69:00:02:d6; 1 Fabric Port Name: 20:03:00:60 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 413
display local NS information with aliases with the -r and -t options: switch:admin> nsaliasshow -r -t { Type Pid COS PortName NodeName SCR N 021200; 2,3;10:00:00:60:69:00:03:19;30:00:00:60:69:00:03:19; 3 FC4s: FCIP Fabric Port Name: 20:02:00:60:69:01:44:22 Permanent Port Name - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 414
bit Fibre Channel addresses of all devices in all switches switch to send out a query to every switch The valid values for this format "x ports supporting FC4 code," switch:admin> nsAllShow { 011000 switch:admin> nsAllShow 8 { 0118e2 0118e4 0118e8 0118ef 0214e2 0214e4 0214e8 0214ef 8 FCP Ports } switch - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 415
for N_Port, NL for NL_Port Pid The 24-bit Fibre Channel address COS A list of classes of service supported by the device PortName The device's port World display all switch and device entries discovered by the NS in the fabric: switch:admin> nscamshow Fabric OS Command Reference Manual 383 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 416
Name: 20:02:00:60:69:00:68:19 Permanent Port Name: 10:00:00:60:69:00:ab:ba Switch entry for the -t option: switch:admin> nscamshow -t nscam show for remote switches: Switch entry for 2 20:02:00:60:69:00:68:19 Permanent Port Name: 10:00:00:60:69:00:ab:ba Device type: Physical Initiator Switch - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 417
switches. Each line of output displays: Type U for unknown, N for N_Port, NL for NL_Port. PID 24-bit Fibre Channel address. COS List of classes of service supported in the display. This value indicates what type of RSCN a device registers to receive. Values include: SCR=0 Reserved. SCR - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 418
switch Virtual Contrived device by the switch NPV Device connected to the Nx_Port, using FDISC to log in to the switch switch:admin> nsshow { Type Pid COS PortName NodeName TTL(sec) N 010100; 3;21:00:00:e0:8b:13:08:10;20 Port Name: 20:01:00:05 :12:8a:be;20:00:00:e0:8b:12 Port Name: 20:0e:00: - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 419
display local name server information with "-r" and "-t" options. switch:admin> nsshow -r -t { Type Pid COS PortName NodeName SCR N 010100; 3;21:00:00:e0:8b:13:08:10;20:00:00:e0:8b:13:08:10; 1 FC4s: 2 entries } nsAllShow, switchShow Fabric OS Command Reference Manual 387 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 420
NL_Port Pid The 24-bit Fibre Channel address COS A list of classes of service supported by the device switch automatically registers SCSI inquiry data for FCP target devices): FC4 supported online devices zoned with the given device: switch:admin> nszonemember 0x0416e2 3 local zoned members: - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 421
: 22:00:00:20:37:d9:61:ac Device type: Physical Target No remote zoned members To display information about all the online devices zoned with the given WWN: switch:admin> nszonemember 10 Pid: 0xb00e00 Aliases: dl360_130251a dl360_130251a Fabric OS Command Reference Manual 389 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 422
Pid: 0xba1ae4 Aliases: trimm100a_2 To display all the unzoned devices in the fabric: switch:admin> nszonemember -u Pid: 0xb01ea9; Aliases: trimm32b_1 Pid: 0xb01eaa; Aliases: trimm32b_2 Pid in the fabric. See Also cfgShow, nscamShow, nsShow 390 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 423
with an account name argument, the password change is accepted for that account. switch and the password database is distributed to the switches in the fabric. After a successful password password and, if your entry is valid, then enter the new password. • If you are changing another user's password, - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 424
changed all the login passwords from the manufacture default values. If the fabric is in secure mode, the behavior of the command is as follows: • The command can only be run on the primary FCS switch. The changed passwords will be distributed to all FCS switches. Non FCS switches will be updated - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 425
cannot change the password before the minimum ageing period expires. Password contains invalid characters.You have entered a password that contains invalid characters. Refer to the Fabric OS Message Reference for more information. login, logout, passwdCfg Fabric OS Command Reference Manual 393 53 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 426
value -warning value -lockoutthreshold value -lockoutduration value -repeat value -sequence value --disableadminlockout --enableadminlockout --setdefault --showall --set --help Description Use this command to manage password policies. When secure mode is enabled, passwdCfg is not supported - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 427
switch instance password. The minimum can be set as 8 to 40. Passwords must be between the minimum length specified to 40 characters. The default value is 8. The total of -lowercase, -uppercase, -digits, -punctuation must be less than or equal to -minlength value. Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 428
0 disables password expiration. The default value is 0. -warning value Specifies the number of days prior to password expiration that a warning of password expiration is passwdcfg.lockoutduration" duration. The particular account is unlocked manually using userconfig --change -u by - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 429
of allowed values is 1-40. The default value is 1. Examples To display the current password configuration parameters: switch:admin> passwdcfg execute the command. Command not supported passwdCfg is not supported when secure mode is enabled. Fabric OS Command Reference Manual 397 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 430
must be between 0 and 999. maxpasswordage value out of range The -maxpasswordage value must be between 0 and 999. warning value out of range The -warning value must be between 0 and 999. invalid password expiration specification The -minpasswordage value or -warning value must be less than or equal - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 431
or failure. It might fail if a switch along the path is busy: for instance, if a switch is performing a warm recovery or if a switch along the path does not support this feature. If the advanced performance is currently recognized by FSPF. Fabric OS Command Reference Manual 399 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 432
from the source switch to the destination switch. In order requested. The default value for the value reports for value A on switch X to port B on switch Y might switches, or the reverse path might even involve different switches a sequence of switches, ports, or as a sequence of switches, a sequence of - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 433
specified. Default: No. strict source rte Specifies that the source route must be followed strictly as indicated, skipping possible intermediate switches. When using this option, the source route hops must be specified using domain rather than output port. Fabric OS Command Reference Manual 401 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 434
default is 10 seconds. Examples To display basic path information to a specific domain, using the command line (noninteractive mode): switch using interactive mode: switch:admin> pathinfo Max 64s) 5 5 5 5 Txcrdz (1s) 0 - 0 - Txcrdz (64s) 0 - 0 - F/s (1s) 1 1 0 0 F/s (64s - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 435
pathInfo 2 Hop In Port Domain ID (Name) Out Port BW Cost 2 14 8 (web228) E - - (output truncated) See Also portStatsShow, switchShow Fabric OS Command Reference Manual 403 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 436
available on the switch. If a 16:06:11 UTC 2002 Kernel= 2.4.19 Fabric OS= v4.1.0_j_dist_1103 Made on= Tue Dec 3 19:07:13 2002 Flash= Tue Dec 3 13:19:06 2002 BootProm= 3.2.0 Section=HA show Output (output truncated) See Also portLogDump, saveCore 404 Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 437
are considered identical if they have the same SID and DID values after applying the end-to-end mask. After a successful execution . This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports Reference Manual 405 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 438
To add an end-to-end monitor to blade 1 port 2: switch:admin> perfaddeemonitor 1/2 "0x050200" "0x1182ef" End-to-End monitor number , perfAddUserMonitor, perfAddWriteMonitor, perfClearEEMonitor, perfDelEEMonitor, perfShowEEMonitor 406 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 439
command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC order to include spaces. This operand is optional. The default alias is "IP Frame". The interfaces will accept IPv6 monitor to a port: switch:admin> perfaddipmonitor 1/4 "IP_MONITOR - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 440
IP frame monitor. This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port is optional. The default alias is "SCSI Read". . Examples To add an SCSI read monitor to a port: switch:admin> perfaddreadmonitor - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 441
This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports order to include spaces. This operand is optional. The default alias is "SCSI R/W". Optionally, a comma can monitor to a port: switch:admin> perfaddrwmonitor 2/4 "SCSI_RW - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 442
. This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports ( order to include spaces. This operand is optional. The default alias is "SCSI Frame". Optionally, a comma can monitor to a port: switch:admin> perfaddscsimonitor 2/4 " - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 443
monitor numbers and user-defined aliases can be retrieved with the perfShowFilterMonitor command. This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. Bloom-based platforms - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 444
in order to include spaces. This operand is optional. By default, the alias is an empty string. . Examples To add a filter-based monitor for all Extended Link Service requests (R_CTL=0x22 and TYPE=0x01) to a port: switch:admin> perfaddusermonitor 1/4 "4, 0xff, 0x22; 12, 0xff, 0x01" User monitor - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 445
command. This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port optional. The default alias is "SCSI_Write". Examples To add an SCSI Write command monitor to a port: switch:admin> perfaddwritemonitor - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 446
This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports ( performance monitoring information from nonvolatile memory: switch:admin> perfcfgclear This will clear Performance Monitoring settings in FLASH. The RAM settings won't change - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 447
: switch:admin> perfcfgrestore This will overwrite current Performance Monitoring settings in RAM. Do you want to continue? (yes, y, no, n): [no] y Please wait ... Performance monitoring configuration restored from FLASH. See Also perfCfgClear, perfCfgSave Fabric OS Command Reference Manual 415 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 448
memory. This enables the performance monitoring configuration to be saved across power cycles. The number of monitors saved to flash memory has the following limitations: 16 EE monitors 16 filter monitors A total number of 512 monitors per a switch When there are more than 512 monitors in the system - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 449
error counter associated with a specific port and AL_PA, or all such counters on a port. This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. The execution of this command - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 450
a Brocade Advanced Performance Monitoring license. This command is not supported on switch:admin> perfcleareemonitor 1/2 This will clear ALL EE monitors' counters on port 2, continue? (yes, y, no, n): [no] y See Also perfAddEEMonitor, perfShowEEMonitor 418 Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 451
monitorId. Issuing portStatsClear on a port also results in all filter-based monitors clearing. This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. This command is - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 452
port. This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/ on a port, or all such monitors: switch:admin> perfdeleemonitor 7/2 5 End-to-End monitor number 5 deleted switch:admin> perfdeleemonitor 7/2 This will remove ALL - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 453
requires a Brocade Advanced Performance Monitoring license. This command is not supported on switch:admin> perfdelfiltermonitor 2/3 This will remove ALL monitors on port 19, continue? (yes, y, no, n): [no] y See Also perfAddUserMonitor, perfShowFilterMonitor Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 454
to performance monitoring: switch:admin> perfhelp perfAddEEMonitor monitor - SCSI Write Clear Performance settings from FLASH Restore Performance configuration from FLASH Save Performance configuration to FLASH Clear an end-to-end monitors' counters Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 455
and filter-based monitors (but not ISL monitors) for all the ports in the same quad. This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. The execution of this command is - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 456
2 perfMonitorClear switch:admin> perfmonitorclear --class ISL 1 This will clear ISL monitor on port 1, continue? ( , perfAddReadMonitor, perfAddRWMonitor, perfAddSCSIMonitor, perfAddUserMonitor, perfAddWriteMonitor, perfMonitorShow 424 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 457
monitors (FLT), and Inter-Switch Link monitors (ISL). ISL Cumulative 64-bit frame count If you do not specify a value for 64-bit cumulative ISL transmit count for the whole ISL Num_ports Number of ports in this ISL (one for a standalone ISL, more for trunks) Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 458
64-bit cumulative transmit counter for each individual domain This command requires a Brocade Advanced Performance Monitoring license. This command is not supported ISL (interswitch link). These values are case-sensitive. slotnumber For switch the switch 6 seconds: switch:admin> perfmonitorshow - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 459
To display cumulative filter monitor information on a port: switch:admin> perfmonitorshow --class FLT 2/5 There are 7 on a port at an interval of every 6 seconds: switch:admin> perfmonitorshow --class FLT 2/5 6 perfmonitorshow 21, 6 port: switch:admin> perfmonitorshow --class EE 4/5 There are 7 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 460
97: 110379 Domain 98: 13965 Domain 99: 1337982 To display EE moniors configured on port number 0: switch:admin> perfmonitorshow --class EE 0 There is 1 end-to-end monitor defined on port 0. KEY SID perfAddUserMonitor, perfAddWriteMonitor 428 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 461
. The default EE mask value upon power-on is already set. When ISL monitoring is enabled, EE mask on E_Ports are controlled automatically and existing mask values for E_Ports are over-written. This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 462
trigger the EE monitor. 00 ff TxDIDMsk RxSIDMsk RxDIDMsk Specify the following values to turn on or off a specific field: Specifies that the Examples To set the overall mask for end-to-end monitors on a port: switch:admin> perfsetporteemask 1/6 "00:00:00" "ff:ff:ff" "00:ff Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 463
64-bit counter. The CRC count value is displayed in hexadecimal. This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on the Brocade all AL_PA devices on a port: switch:admin> perfshowalpacrc 2/4 ALPA CRC_ERROR_COUNT 0x01 0 0x03 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 464
requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual EE monitors configured on the switch port 0: switch:admin> perfshoweemonitor 0 There configured on the switch port 0 using an application that passes an IPV6 address: switch:admin> perfshoweemonitor - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 465
a port at an interval of every 6 seconds: switch:admin> perfshoweemonitor 4/5 6 perfshoweemonitor 53, 6: Tx/ 52m 0 To display cumulative information from EE monitors on a port: switch:admin> perfshoweemonitor 4/5 There are 7 end-to-end monitor(s) defined platforms do not support counting CRC - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 466
traffic count values. This command Brocade Advanced Performance Monitoring license. This command is deprecated; use perfMonitorShow instead. This command is not supported at an interval of every 6 seconds: switch:admin> perfshowfiltermonitor 2/5 6 perfshowfiltermonitor 21, 6 Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 467
2 To display filter monitor information on a port: switch:admin> perfshowfiltermonitor 2/5 There are 7 filter-based monitors defined perfAddReadMonitor, perfAddRWMonitor, perfAddSCSIMonitor, perfAddUserMonitor, perfAddWriteMonitor Fabric OS Command Reference Manual 435 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 468
modify the value of the default value of the EE mask is all fields set to "on." This command requires a Brocade Advanced Performance Monitoring license. This command is deprecated; use perfMonitorShow instead. This command is not supported switch:admin> perfshowporteemask 2/4 The EE mask onport 20 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 469
perfShowPortEEMask 2 RxSID ALPA: on RxDID Domain: on RxDID Area: on RxDID ALPA: on See Also perfAddEEMonitor, perfDelEEMonitor, perfSetPortEEMask, perfShowEEMonitor Fabric OS Command Reference Manual 437 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 470
generated... Installing Root Certificate... If run in secure mode, the following error message is displayed: switch:admin> pkicreate Warning !! Switch is in secure mode. Cannot create new Pki Objects. Exiting... See Also pkiRemove, pkiShow 438 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 471
switch private key, private key pass-phrase, CSR, root certificate, and switch switch:admin> pkiremove WARNING!!! Removing switch. If you want secure mode enabled, you will need to get the switch error message is displayed: switch:admin> pkiremove This Switch is in secure mode. Removing - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 472
of PKI objects, such as switch private key, private key pass-phrase, CSR, root certificate, and switch certificate. The execution of this command that may be in place. Operands none Examples To view PKI objects: switch:admin> pkishow Passphrase : Exist Private Key : Exist CSR : Exist - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 473
values are 1 to 32, and ALL with the --show option. Optional -enc method Operands -auth algorithm -pfs value -dh group Specifies the encryption algorithm. The default is AES-128. Methods include: 3DES Triple data encryption standard, 192-bit key. AES-128 Advanced encryption standard, 128-bit - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 474
must be between 28800 to 250000000 or 0. The default is 28800. Examples To create a new policy: switch:admin> policy --create ike 10 -enc 3des - all IPSec policy settings: switch:admin> policy --show ipsec all IPSec Policy 2 Authentication Algorithm: SHA-1 Encryption: AES-128 SA Life (seconds): - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 475
switch:admin> policy ike --create 10 -enc aes-128 -auth sha-1 The following policy has been set: IKE policy 10 Authentication Algorithm: SHA-1 Encryption: AES-128 Perfect Forward Secrecy: 0 Diffie-Hellman Group: 1 SA Life (seconds): 28800 To delete a policy: switch:admin> - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 476
the port number to display, relative to its slot for bladed systems. Use switchShow to list valid ports. Examples To display the AL_PAs of a port: switch:user> portalpashow 4/14 AL_PA type AL_PA 0xe2 public 0xe4 type public AL_PA type See Also switchShow 444 Fabric OS Command Reference - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 477
groups in the switch. Synopsis portbuffershow all of the port groups of the switch is displayed. The following long distance information and then echoed back to the switch. The supported distance measurement is up to 500 If the connecting port does not support LD mode, is shows "N/A". Remaining - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 478
. Examples To display the long distance information a port: switch:user> portbuffershow 17 User Port Lx Max/Resv Buffer Needed Link Remaining Port Type Mode Buffers Usage Buffers Distance Buffers 16 - - 0 - - 17 E L1 - 54 54 50km 18 - - 0 - - 19 - - 0 - - 54 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 479
if omitted, information for all ports is displayed. Ports that support shared areas are divided into two ports: primary and secondary ports 7/31 is primary. In this case portcamshow entries will look like below: switch:user> portcamshow 7/39 Area SID used DID used SID entries DID entries 207 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 480
CAM utilization for all ports on a switch: switch:user> portcamshow Ports of Slot 9 Port SID used DID used SID free DID free 0 0 0 64 512 1 0 0 64 512 2 0 0 64 512 3 0 0 64 512 4 0 0 64 512 5 0 0 64 512 6 0 0 64 512 7 0 0 64 512 8 0 0 63 511 9 0 0 63 511 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 481
the tunnel specified. This argument must be used together with -ike and -key. -k timeout Specifies the keep alive timeout, in seconds. timeout values are 8 to 7,200; default is 10. If tape pipelining is enabled, minimum value supported is 80. Fabric OS Command Reference Manual 449 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 482
time, in milliseconds. time values are 20 to 5,000; default is 100. -n remote_wwn Specifies the remote-side FC entity WWN. -r retransmissions Specifies the maximum retransmissions. retransmissions values are 1 to 16; default is 8. If tape pipelining is enabled, default value is calculated based on - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 483
the maximum retransmissions for the existing tunnel. retransmissions values are 1 to 16; default is 8. If tape pipelining is enabled, default value is calculated based on the mininum retransmit time . Use switchShow for a list of valid ports. Fabric OS Command Reference Manual 451 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 484
Brocade 7500 or an FR4-18i blade are 1260 to 2348. gateway Specifies the gateway IP address for the route. metric Specifies the link metric associated with the route. Valid values are 0 to 255. The default between two Brocade 7500 routers or two Brocade 48000 directors with Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 485
switch:admin> portcfg iproute ge0 create 172.16.123.231. 255.255.0.0 192.168.255.25 1 Operation Succeeded To create an FCIP tunnel: switch:admin> portcfg fciptunnel ge0 create 2 192.168.255.2 192.168.255.20 Mirror Port .. .. .. .. ON Fabric OS Command Reference Manual 453 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 486
..:OFF, ??:INVALID. LM:L0.5 To configure a range of ports as RSCN supressed: switch:admin> portcfg rscnsupr 2/4-7 --enable switch:admin> portcfgshow [output from other slots suppressed] Ports of Slot 2 0 1 2 3 configure, portShow, switchShow 454 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 487
the port to be returned to default values, relative to its slot for bladed systems. Use switchShow to list valid ports. Examples To reset a port to factory defaults: switch:admin> portcfgdefault 1/3 To reset a GbE port to factory defaults: switch:admin> portcfgdefault 8/ge1 See Also portCfgEPort - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 488
a port from becoming an E_Port. The E_Port capability is enabled by default unless this command is used to disable it. When a port is configured switches, the maximum routing paths are currently limited to 16 E_Ports. Changes made by this command are persistent across switch reboots or power cycles - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 489
fabricid Specify the fabric ID. Valid values are 1-128. -r ratov Specify the R_A_TOV used for port negotiation. Valid values are 2000 120000. This operand is only applicable if the "Fabric Parameter" attribute value is not "Auto Negotiate". Fabric OS Command Reference Manual 457 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 490
: OK Pid format: core(N) Operate mode: Brocade Native Edge Fabric ID: 16 Front Domain ID: 160 Front WWN: 50:06:06:9e:20:9f:ce:10 Principal Switch: 7 principal WWN: 10:00:00:60:69:c0:05:8a Fabric Parameters: Auto Negotiate R_A_TOV: 9000(N) E_D_TOV: 2000(N) Edge fabric's primary - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 491
portCfgEXPort 2 See Also switch:admin> portcfgexport 2/0 -t 2 portCfgVEXPort, portDisable, portEnable, portShow, portCfgDefault, fcrbcastconfig Fabric OS Command Reference Manual 459 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 492
persistent across switch reboots or power cycles. The value of 0 is the default port state. This operand is required. Examples To configure a port as a locked G_Port: switch:admin> portcfggport 1/3, 1 See Also configure, portCfgLPort, portShow, switchShow 460 Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 493
configure command for more information on the core PID format. This configuration can be cleared consistent for every switch in the L1, and L2 are no longer supported in v5.3.0. • Trunk port • is persistent across reboots and power cycles. Use the portCfgShow command to Manual 461 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 494
. Specify 0 to disable ISL R_RDY mode. To enable ISL R_RDY mode on a port: switch:admin> portcfgislmode 1/3, 1 ISL R_RDY Mode is enabled for port 3. Please make sure the To disable ISL R_RDY mode on a port: switch:admin> portcfgislmode 1/3, 0 See Also configure, portCfgLongDistance, portCfgShow 462 Fabric - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 495
support a long-distance link up to 500 Km. The port can be used only as an E_Port. This configuration can be cleared but not set on VE/VEX_Ports. Changes made by this command are persistent across switch reboots or power cycles. This command requires a Brocade Extended Fabrics license. The value - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 496
backward compatible with firmware versions that do not support it. If a Brocade 3250, 3850, and 3900 switches and Brocade 24000 and 48000 directors using FC2-16 Brocade 200E,4100, and 4900 switches and Brocade 48000 directors using FC4-16 and FC4-32 values for port number vary, depending on the switch - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 497
value. Examples To configure a switch port 63 to support switch:admin> portcfglongdistance 4/15 LS 1 100 switch:admin> portshow 4/15 portCFlags: 0x1 portFlags: 0x20001 PRESENT LED portType: 1.1 portState: 2 Offline portPhys: 4 No_Light portScn: 0 portId: 013f00 portWwn: 20 Manual 465 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 498
optional; if omitted; the default value of 0 is used. Private devices are supported only on Brocade 3250, 3850, and 3900 and directors with FC2-16 and FC2-16 blades. For other switches and blade types, option R_RDY Mode Persistent Disable 466 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 499
portCfgLPort 2 where AN:AutoNegotiate, ..:OFF, ??:INVALID. To display the L_Port conditions: switch:admin> portcfglport [output from other slots suppressed] Ports of Slot 4 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Locked L_Port ON Private L_Port Locked Loop HD Loop - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 500
the enterprise fabric switch that supports NPIV. The switch. The default value for mode is 0 (disabled) and if the value 1 (enabled). Examples To enable N_Port functionality for a port: switch 12 13 14 15 Locked N_Port .. .. .. ON ON or switch:admin> portcfgshow Ports of Slot 0 0 1 2 3 4 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 501
0 to 255 per port. The default value is 126 per port. The number of virtual port IDs per switch also can be configured. See configure for more information on configuring these values. Changes made by this command are persistent across switch reboots and power cycles. Use the portCfgShow command to - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 502
ON ON ON ON ON ON ON ON ON ON where AN:AutoNegotiate, ..:OFF, ??:INVALID. LM:L0.5 See Also To disable NPIV functionality on a port: switch:admin> portcfgnpivport 1/3 0 configure, portCfgDefault, portCfgShow 470 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 503
/]portnumber Description Use this command to persistently disable a port. Persistently disabled ports remain disabled across power cycles, switch reboots, and switch enables. By default, a port is enabled persistently. The change in configuration is effective immediately. The persistent disable - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 504
a port. Persistently enabled ports remain enabled across power cycles, switch reboots, and switch enables. By default, a port is enabled persistently. The change in , portEnable, portCfgPersistentDisable, portCfgShow, portShow, switchShow 472 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 505
a switch, except with the switch model and port negotiation mode). This value is set by the on the port. This value is set by the user input This value is set by distance mode. This value is set by the as a U_Port). This value is set by the portCfgLPort as a U_Port). This value is set by the - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 506
mode disabled. This value is set by value is value Mode disabled. This value is set by the value is set by the portCfgNPIVPort command. It is enabled by default for Condor-based ports and disabled by default as control connection: switch:admin> portcfgshow fciptunnel 20 Compression off Fastwrite off - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 507
Configured Local WWN 10:00:00:05:1e:37:00:20 Compression off Fastwrite off Tape Pipelining off Uncommitted bandwidth, 10, DSCP (Data): 50 To display the configuration settings for a port with agmode enabled: switch:admin> portcfgshow Ports of Slot 0 0 1 2 3 4 5 6 7 8 9 Manual 475 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 508
memory and is persistent across switch reboots or power cycles. This configuration cannot be set of a port. This operand is required. Valid values are one of the following: 0 Autosensing mode. switch:admin> portcfgspeed 2/3, 2 See Also portCfgShow, portShow, switchCfgSpeed 476 Fabric - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 509
ports might be disrupted for a period of time. This command requires a Brocade ISL Trunking license. The execution of this command is subject to Admin Domain is required. Examples To enable a port for trunking: switch:admin> portcfgtrunkport 1/3, 1 See Also portCfgShow, portShow, switchCfgTrunk, - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 510
to them. The negotiated values are what the edge switch specifies in the ELP request. If the state is "Not OK", the R_A_TOV and E_D_TOV display "Not Applicable". By default, all EX_Ports are auto-ELP enabled. The port ID format is applicable only when port_mode is "Brocade Native". If the Fabric - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 511
: enabled State: OK Pid format: core(N) Edge Fabric ID: 16 Front Domain ID: 160 Front WWN: 50:06:06:9e:20:9f:ce:10 Principal Switch: 7 principal WWN: 10:00:00:60:69:c0:05:8a Fabric Parameters: Auto Negotiate R_A_TOV: 9000(N) E_D_TOV: 2000(N) Edge fabric's primary wwn: N/A Edge - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 512
or trace route to a destination IP host from an intelligent GbE port. Currently we do not support end-to-end path characterization if there exists an IPSec-enabled tunnel using the same source/local IP end-point. This operand is optional. 480 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 513
connection. This operand is 0 to 63 (inclusive). The default value is 0. --ipperf output displays: Sampling frequency(s) This without fragmentation. This value is measured in bytes and includes the IP header and payload. Note: There is limited support for black hole PMTU Manual 481 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 514
value to first_ttl. The default service in the traceroute request. The default default is 64 bytes. The total size, including ICMP/IP headers (28 bytes without IP options) cannot be greater than the IP MTU configured on the interface. This operand is optional. 482 Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 515
switch:admin> portcmd --ping 3/ge0 -s 193.10.2.1 -d 193.10.2.49 Pinging 193.10.2.49 from ip interface 193.10.2.1 on 3/ge0 with 64 bytes of data Reply from 193.10.2.49: bytes=64 rtt=0ms ttl=64 Reply from 193.10.2.49: bytes=64 rtt=0ms ttl=64 , Fabric OS Command Reference Manual 483 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 516
for port modules; valid values are 1 to 5. vbs_lvl Specify the verbose level to be set for port modules; valid values are 1 to 5. Examples To set debug level and verbose level of port modules: switch:admin> portdebug 3 4 See Also dbgShow 484 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 517
. If the port is connected to another switch, the fabric might reconfigure. Devices connected to The front-panel LED of a disabled port flashes yellow with a two-second cycle. The execution of this command is subject Examples To disable a port: switch:admin> portdisable 2/4 See Also - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 518
If the port is connected to another switch, the fabric might reconfigure. Devices connected is rejected if the port's switch is disabled, the port's blade is not fully enabled (faulted, powered off, or disabled), or if Examples To enable a port: switch:admin> portenable 2/4 See Also - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 519
error counters for ports on a switch: switch:admin> porterrshow frames enc crc too 0 0 13: 0 0 0 0 0 0 0 0 0 0 0 2 0 0 14: 0 0 0 0 0 0 0 0 0 0 0 2 0 0 15: 0 0 0 0 0 0 0 0 0 0 0 2 0 0 16: 0 0 - 0 0 0 0 - 0 - - - - 17: 0 0 - 0 0 0 0 - 0 - - - - - Fabric OS Command Reference Manual 487 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 520
2 portErrShow 18: 0 0 - 0 0 0 0 - 0 - - - - 19: 0 0 - 0 0 0 0 - 0 - - - - 20: 0 0 - 0 0 0 0 - 0 - - - - 21: 0 0 - 0 0 0 0 - 0 - - - - 22: 0 0 - 0 0 0 30: 0 0 - 0 0 0 0 - 0 - - - - 31: 0 0 - 0 0 0 0 - 0 - - - - - See Also portShow, portStatsShow 488 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 521
switch. Synopsis portflagsshow Description Use this command to display the following status for a port: SNMP Displays whether the port is online or offline. Physical Displays the port physical status. Valid values Also portShow, switchShow Fabric OS Command Reference Manual 489 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 522
completed, the ATTN LEDs flash amber, indicating that the command has finished and exited. You can enable the current switch (using the switchEnable command The default value is 10. -ports itemlist Specify a list of user ports to run the test. If omitted, all the active ports in the switch are - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 523
information. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To clear the port log: switch:admin> portlogclear switch:admin> portlogshow port log is empty See Also portLogDump, portLogShow Fabric OS Command Reference - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 524
execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To display the current port log configuration: switch:admin> portlogconfigshow max portlog entries = 8192 See Also portLogResize 492 Fabric OS Command Reference - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 525
. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands None. Examples To display the port log facility: switch:admin> portlogdisable See Also portLogEnable Fabric OS Command Reference Manual 493 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 526
is optional. saved Specify a nonzero value to display the saved port log from the last switch fault. Refer to upTime for conditions optional. Examples To display the port log for a port: switch:user> portlogdump 20 time task event port cmd args 08:35:27.899 tShell Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 527
the switch firmware, switch, switch-to-switch, some device-to-device1, and control information If the port log is disabled, the following message displays as the first line. Refer to portLogClear command for more information. WARNING: port log is disabled Refer to the Fabric OS Administrator's Guide - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 528
. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands None. Examples To enable the port log facility. switch:admin> portlogenable See Also portLogDisable 496 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 529
events: switch:admin> pstate 0 16 reject 0 17 busy 0 18 ctin 0 19 ctout 0 20 errlog 0 21 32 frame 0 33 msRemQ 0 34 msRemR 0 35 nsRemQ 0 36 nsRemR 0 37 rscn 0 38 state 0 39 xalloc 0 (continued on next page) Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 530
40 xfree 0 41 xerr 0 42 xstate 0 43 seq 0 44 seqst 0 45 iu 0 46 payload 0 47 zone 0 48 cmd 0 49 event 0 50 msg 0 51 switch 0 52 ficonq 0 53 routing 0 See Also portLogTypeDisable, portLogTypeEnable 498 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 531
default frame size for this login. cos Class of Services supported. This can be a combination of the following bits: 4 Class 2 is supported. 8 Class 3 is supported one FLOGI (type fe) and two PLOGIs): switch:admin> portloginshow 23 Type PID World Wide Name Manual 499 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 532
be in place. Operands This command has the following operand: lvl Specify either 0 to clear or 1 to set the debug_pdisc_flag. Examples To set the pdisc_flag: switch:admin> portlogpdisc 1 PDISC log setting = 1 See Also none 500 Fabric OS Command Reference - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 533
facility. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To enable the port log: switch:admin> portlogreset See Also none Fabric OS Command Reference Manual 501 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 534
to be resized. The valid range of values is 32,768 to 65,536 for Brocade 48000 Director and Brocade 7500 Switch, and 8,192 to 16,384 for all others. Examples To resize the portlog: switch:admin> portlogresize 12288 See Also portLogConfigShow 502 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 535
. Port logs are circular log files in the switch firmware, which can save up to 32,768 entries. Refer to portLogConfigShow to display the current event date and time in milliseconds. The clock resolution is 16 milliseconds. Task Displays the name of the task that logged Manual 503 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 536
state Frame payload Displays the port number that logged the event. Defined by the event. Displays a value defined by the event as follows: I/O control command code Frame payload size New state (see = disable ports State (refer to state codes next) Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 537
two 16-bit fields: [A] a bit map value is usually equal to the first word of a loop init frame payload. Other possible values include: 2 LIP (req. INITIALIZING) timeout 94F0F0ARB(F0) timeout 40 CLS timeout Codes used in various fields are as follows: state Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 538
not empty but E_Port loopback 8009LIP as requested by the LINIT ELS received 800aLIP as requested by the LPC ELS received 800bRestart loop for QuickLoop looplet setup 800cRestart loop for NF Negotiation follow NC Negotiation complete 506 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 539
by this command, refer to the Fabric OS Administrator's Guide. The execution of this command is subject to Admin operand is optional. saved Specify a nonzero value to display the saved port log from the last switch fault. Refer to upTime for a list of Command Reference Manual 507 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 540
Specify the port number of the port to display. Examples To display a port log for port 14: switch:user> portlogshowport 14 time task event port cmd args 08:35:28.483 tFabric scn 14 0 08 See Also portLogClear, portLogShow, upTime 508 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 541
. The values corresponding to different log types can be obtained by running portLogEventShow. Examples To disable event 2 from reporting to the port log: switch:admin> portlogtypedisable 2 See Also portLogDisable, portLogEventShow, portLogTypeEnable Fabric OS Command Reference Manual 509 53 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 542
be enabled. The values corresponding to different log types can be obtained by running portLogEventShow. Examples To enable event 2 to report to the port log: switch:admin> portlogtypeenable 2 See Also portLogEventShow, portLogTypeDisable 510 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 543
functional operation of the switch by sending frames from the eight statistic error counters for nonzero values: ENC_in, CRC_err, TruncFrm, FrmTooLong, 3 receiver counters are stuck at some value. Check if the number of frames to determine which components of the switch are faulty. The execution of - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 544
default default value is 10. -lb_mode mode Specify the loopback mode for the test. By default, this test uses internal loopback. Valid values (Bloom default). 4 Runs test at 4 Gbit/sec (Condor default). For lb_mode to test. By default, all of the switch:admin> portloopbacktest -ports 1/10-1/20 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 545
STATS TIMEOUT XMIT Refer to the Fabric OS Message Reference for more information. camTest, centralMemoryTest, cmemRetentionTest, cmiTest, itemList, portRegTest, spinSilk, sramRetentionTest Fabric OS Command Reference Manual 513 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 546
switch). A port mirroring connection on FL_Ports mirrors all traffic originating or terminating from this FL_Port. Port mirroring does not support connection. To display all configured mirror ports on a switch use the portCfgShow command. 514 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 547
port mirroring feature is only supported on the following platforms: Brocade 4100, Brocade 4900, Brocade 7500, and Brocade 48000 Option 5. The mirror port location can impact the latency of mirrored frames. Setting up multiple mirror connections on a core-edge platform between devices will mirror - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 548
To display port mirror connections: switch:admin> portmirror --show Number of mirror connection(s) configured: 2 Mirror_Port SID DID State 10/12 0x791800 0x791900 Defined 10/15 0x791a00 0x799300 Enabled See Also portCfgShow 516 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 549
attributes, port name persists across reboots and power cycles. It is not affected by configDefault The port name is a character string up to 32 characters, including spaces and characters, and excluding drive 8: switch:admin> portname 1/3, "Tape drive 8" switch:admin> portname 1/3 Tape drive - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 550
Values are always rounded down. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands This command has the following operand: interval Specify the interval, in seconds, between each sample. Default for a switch: switch:user> portperfshow 20 0 1 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 551
-1 test. 0x10 Skip credit counter test. -verbose mode Specify a nonzero value to enable verbose mode. The default value is to disable this mode. Examples To run a bit write/read test of the ASIC SRAMs and registers: switch:admin> portregtest -ports 1/0-1/15 Running Port Register Test .... Test - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 552
See Also Refer to the Fabric OS Message Reference for more information. camTest, centralMemoryTest, cmemRetentionTest, cmiTest, itemList, portLoopbackTest, spinSilk, sramRetentionTest 520 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 553
frames destined to the embedded port (value 0x10000) of the local domain. Bit 16 set (value 0x10000), indicating this port always routes broadcast frames to the embedded port, for handling by the firmware display the routing tables for a port: switch:user> portrouteshow 4/15 port address ID: 0x02bf00 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 554
2 portRouteShow broadcast routing table: 0x10000 See Also bcastShow, fabricShow, switchShow, topologyShow, uRouteShow 522 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 555
specific to the operand given. This will vary with the switch model and port type. See the OPERANDS section for details. by portDisable or portCfgPersistentDisable. portCFlags Port control flags. portFlags Bit map of port status flags, including information on the type Manual 523 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 556
generation number for the last offline state change. portId 24-bit port ID. portIfId User port's interface ID. portWwn Port front domain and the WWN of the front domain. Pr Switch Info Information on the principal switch of the edge fabric attached to this EX_Port. This Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 557
passwords are configured both on the router and the edge switch, the security type is displayed as "DH_CHAP". DH-CHAP is the only supported authentication type. DH Group If the EX_Port is connected to an edge switch with no security, then the value OS Command Reference Manual 525 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 558
valid ports. Examples To display the state of a port: switch:admin> portshow 3 portName: portHealth: HEALTHY Authentication: None 1 Online portPhys: 6 In_Sync portScn: 64 Segmented port generation number: 26 portId: 4c0300 portIfId: 43020007 portWwn: 20:03:00:05:1e:35:77:bb - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 559
Authentication: None EX_Port Mode: Enabled Fabric ID: 20 Front Phantom: State: OK Cur Dom ID: 160 WWN: 50:00:51:e3:60:ee:0e:14 Pr Switch Info: Dom ID: 5 WWN: 10:00:00:05:1e:34:02:04 Fabric params: R_A_TOV: 10000 E_D_TOV: 2000 PID fmt: core Authentication Type: None Hash Algorithm: N/A DH - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 560
port: switch:admin> portshow ipif ge0 GE Port 0/ge0 Interface IP Address NetMask MTU 0 192.168.255.20 255 as well as control connection: switch:admin> portshow fciptunnel ge0 all 00:05:1e:37:00:20 Compression off Fastwrite off Tape on a GbE port: switch: admin> portcfgshow ge0 Persistent - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 561
WWN Not Configured Local WWN 10:00:00:05:1e:37:00:20 Compression off Fastwrite off Tape Pipelining off Uncommitted bandwidth, minimum of 1000 .255.27 0 Interface, 172.16.123.231 255.255.0.0 192.168.255.25 1 See Also To display iSCSI Port WWN and Sessions: switch:admin> portshow isci 2/ge0 GE - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 562
64-bit hardware statistics for a port. Synopsis portstats64show [slotnumber/]portnumber Description Use this command to display the following hardware statistics for a port. Two integers are reported for most values Byte rate (Bytes/sec). 530 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 563
switchShow to display a list of valid ports. Examples To display the 64-bit hardware statistics for a port: switch:user> portstats64show 4/15 stat64_wtx 0 top_int : 4-byte words transmitted 316 bad end-of-frame (continued on next page) Fabric OS Command Reference Manual 531 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 564
: 4-byte words transmitted 0 bottom_int : 4-byte words transmitted stat64_rxClass1Frames 0 top_int : 4-byte words transmitted 0 bottom_int : 4-byte words transmitted See Also portStatsClear, portStatsShow 532 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 565
End-to-End monitor, and Filter-based performance monitor statistics. Inter-Switch Link (ISL) monitor statistics are not cleared by this command. For for a port: switch:admin> portstatsclear 4/15 See Also portStats64Show, portStatsShow Fabric OS Command Reference Manual 533 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 566
and display only with those platforms and ports. All statistics have a maximum 32-bit value of 4,294,967,295. stat_wtx stat_wrx stat_ftx stat_frx stat_c2_frx stat_c3_frx stat_lc_rx stat_mc_rx Admin Domain restrictions that may be in place. 534 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 567
Examples To display the basic set of statistics for a port: switch:admin> portstatsshow 13 stat_wtx 0 stat_wrx 0 stat_ftx 0 stat_frx 0 stat_c2_frx for slot 8 and GbE port 1: switch:admin> portstatsshow ge 8/ge1 ge_stat_tx_frms 0 GE transmitted frames Fabric OS Command Reference - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 568
Errors To display port statistics for IP address 192.168.255.10, slot 8, and GbE port 1: switch:admin> portstatsshow ip 8/ge1 192.168.255.10 ipaddr 192.168.255.10 IP address ip_out_octets 159896 Errors 0 IP TCP Data Checksum Errors 536 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 569
See Also portErrShow, portShow portStatsShow 2 Fabric OS Command Reference Manual 537 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 570
using portSwapEnable. The result of this operation is persistent across reboots and power cycles. To undo a previous port swap, execute portSwap again on the same . Examples To swap area numbers between a pair of ports: switch:admin> portswap 1/3 2/5 portswap done See Also portDisable, portEnable - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 571
state of the portswap feature is persistent across reboots and power cycles. Enabling or disabling the portswap feature does not effect switch:admin> portswapdisable See Also portSwap, portDisable, portEnable, portShow, portSwapEnable, portSwapShow, switchShow Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 572
of the portswap feature is persistent across reboots and power cycles. Enabling or disabling the portswap feature does not effect switch:admin> portswapenable See Also portSwap, portDisable, portEnable, portShow, portSwapDisable, portSwapShow, switchShow 540 Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 573
whose area number id different from the default area number. The default area number of a port is same as its switch port number. The execution of this and information for ports whose area numbers have been swapped: switch:admin> portswapshow PortSwap is enabled Slot Slotport Swport Area 2 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 574
problems to a single replaceable element and isolate problems switch components from the main board, to the fiber cable, to the media (of the devices and the switch -wavelength media (switch) port is supported: E_Ports F_Ports (must support ELS default, all the user ports in the switch are - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 575
number of frames per port) to execute this test. Default value is 20. Valid values include: 0 Run the test on timeout mode. -1 switch: switch:admin> porttest -ports 1/1-1/3 See Also fportTest, loopPortTest, portLoopbackTest, portTestShow, spinFab, stopPortTest Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 576
. portTest start time. portTest stop time. Timeout value. Error code if any. The execution of this a list of user ports to test. By default, all the user ports in the current slot Examples To display information from portTest: switch:admin> porttestshow 1 Port 1 Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 577
enforced zone type of the F/FL-ports of a switch. Output shows virtual port number (decimal), physical port default zoning is enabled with "No Access" mode, "No Effective configuration: (No Access)" is displayed. This command requires a Brocade Fabric OS Command Reference Manual 545 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 578
power causes the CP boards' processors to cease execution of the firmware. In this situation, all operation of the system terminates immediately: for instance, if two power supplies already have been removed from a Brocade director To modify the power-off list order: switch:admin> powerofflistset - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 579
POL Power Off Order 10 1 1st 9 2 2nd 8 3 3rd 7 4 4th 4 10 5th 3 9 6th 2 8 7th 1 7 8th Proceed to change the POL order? (yes, y, no, n): [no] y See Also chassisShow, powerOffListShow, psShow, slotPowerOff, slotPowerOn, slotShow Fabric OS Command Reference Manual 547 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 580
Operands none Examples To display the slot power off list order: switch:admin> powerofflistshow Slot 10 will be powered off 1st Slot 9 will be powered off 2nd Slot 8 will be powered off 3rd Slot 7 will be powered off 4th Slot 6 will be powered off 5th Slot 5 will be powered off 6th Slot 4 will be - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 581
is present but predicting failure. faultyPower supply present but faulty (no power cable, power switch turned off, fuse blown, or other internal error). For certain switch models, the OEM serial ID data displays after each power supply status line. The execution of this command is subject to Admin - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 582
switch's console. Only telnet session will be suppressed. By default, quiet mode is disabled, and all switch is suppressed. This is useful when driving a telnet session via a script current value is displayed. Examples To display the current state of quiet mode, and then enable it: switch:admin - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 583
Reboots the control processor (CP) in a switch or a director. Synopsis reboot -f Description Use this command to reboot a CP in a director or a switch. When this command is issued on a switch, if the switch is part of a fabric, all traffic to and from that switch stops. All Fibre Channel ports on - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 584
Operands none Examples To display a list of routing-related commands: switch:admin> routehelp bcastShow dlsShow fspfShow interfaceShow iodShow LSDbShow nbrStateShow topologyShow uRouteShow See Also bcastShow, interfaceShow, uRouteShow 552 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 585
staff. The information displayed might not be supported between releases and is subject to change arbitrarily. Operands none Examples To display the size of the active security database: switch:admin> secactivesize Size of security active data: 35 bytes (Max 262144 bytes) See Also secDefineSize - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 586
information. Synopsis secauthsecret [--show] [--set] [--remove value | --all] Description Use this command to manage the next authentication request. The configuration applies to a switch instance only. A Brocade Security license is required to run this command in Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 587
keys. If a fabric requires authentication, deleting this database may cause switch to segment from the fabric. Do want to remove secret key database? (yes, y, no, n): [no] y Deleting secret key database... Done. switch:admin> See Also none Fabric OS Command Reference Manual 555 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 588
Generate a certificate signing request (CSR). • Delete a CSR. • List the certificates present in the switch. • Display the contents of a certificate/CSR. • Delete a specific certificate. • Configure SSL certificate file operands are as follows: 556 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 589
bits switch. This is second step for setting up third-party certificates in the switch switch. delcsr Deletes the CSR in the switch. showcsr Displays the contents of the CSR in the switch switch page breaks. show Displays a list of all certificates in the switch switch. switch switch switch:admin - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 590
suffix): filename Enter Login Name: login Enter Password: password Success: imported certificate [certificate file name]. switch:admin> seccertutil showcsr To display contents of a certificate: switch:admin> seccertutil show certificate file name See Also none 558 Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 591
staff. The information displayed might not be supported between releases and is subject to change arbitrarily. Operands none Examples To display the size of the defined security database switch:admin> secdefinesize Size of security defined data: 35 bytes (Max 262144 bytes) See Also secActiveSize - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 592
53 2 Ready 0.0.0.0 sw2 Primary 10:00:00:60:69:22:32:83 3 Ready 0.0.0.0 sw3 Secured switches in the fabric: 3 IPV6 configured switches may have a link local address, an optional statically configured IPv6 IPv4 address information. 560 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 593
2 See Also To display security related fabric information on the Primary FCS switch with IPV6 and IPV4 address configurations: primaryfcs:admin> secFabricShow Role WWN DId 106 "mps_daz_2" 1080::8:800:200C:417A secPolicyDump, secPolicyShow Fabric OS Command Reference Manual 561 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 594
switch. Operands none Examples To enable a backup FCS switch to take over as the primary FCS switch: switch:admin> secfcsfailover This switch is about to become the Primary FCS switch. All transactions of the current Primary FCS switch 562 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 595
support staff only. The information displayed might not be supported between releases and is subject to change arbitrarily. Operands Examples none To view the current security state: switch Try to remove dom 1 switch 00:00:00:00:00: :90:02:6a (local switch) Stamp 1427583424 ----The latest - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 596
0 ----wwnDL State----domain 1 state 6 domain 2 state 6 domain 10 state 6 pid tid key sec usec --------- LOG CACHE --------- See Also secActiveSize, secDefineSize 564 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 597
mode is enabled or disabled Sets the admin passwd for non-FCS switches Aborts changes to defined policy Activates all policy sets Adds members to temporary password Resets temporary password Aborts current transaction Resets version stamp See Also none Fabric OS Command Reference Manual 565 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 598
. This command can be issued only in secure mode and only from the primary FCS switch. Operands none Examples To disable secure mode: primaryfcs:admin> secmodedisable Please enter current admin account password: Warning!!! About to disable security. ARE YOU SURE (yes, y, no, n): [no] y See Also - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 599
switches in the fabric. Resetting the root, factory, admin, and user account passwords on all FCS switches in the fabric. Resetting the admin and user account passwords on all non-FCS switches no specified FCS switches are present in the fabric, the command can be issued on any switch. Only the -- - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 600
and the user is prompted to enter new passwords for root, factory, admin, user, and non-FCS admin accounts. Examples To enable secure mose with three FCS switches specified by domain, WWN, and switch name: primaryfcs:admin> secmodeenable 568 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 601
. Recovery of a lost Root or Factory password will result in fabric downtime. Changing password for root New FCS switch root password: Re-type new password: Changing password for factory New FCS switch factory password: Re-type new password: Fabric OS Command Reference Manual 569 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 602
password for admin New FCS switch admin password: Re-type new password: Changing password for user New fabric wide user password: Re-type new password: Changing password for admin New Non FCS switch admin password: Re-type new password and do 570 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 603
Switch Certificate, Security license and Zoning license to be installed on every switch switches may go through a reboot to form a secure fabric. Non-FCS admin password will be set the same as FCS admin password passwords are changed will be logged off once passwords on enabled. Passwords of - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 604
a fabric. Operands none Examples To display the current secure mode of a fabric: switch:admin> secmodeshow Secure Mode: ENABLED. Version Stamp: 9182, Wed Mar 17 16:37:01 2004. POS Primary WWN DId swName. 1 Yes 10:00:00:60:69:00:00:5a 21 switch47. 2 No 12:00:00:60:60: - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 605
Non FCS switch admin password: Re-type new password: Login sessions with password changed will be terminated. Password for non-FCS admin account has been changed successfully. See Also passwd, secModeDisable, secModeEnable, secModeShow, secTempPasswdSet Fabric OS Command Reference Manual 573 53 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 606
database that have not been saved to flash memory and to abort changes to policy creation and modification operations from all the switches if fabric-wide consistency policy is not set secPolicyDump, secPolicyRemove, secPolicySave, secStatsShow 574 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 607
mode is enabled, this command can be issued only from the primary FCS switch. Any modifications to SCC DB and DCC DB are saved and activated. When secPolicyCreate, secPolicyDelete, secPolicyDump, secPolicyRemove, secPolicySave, secPolicyShow Fabric OS Command Reference Manual 575 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 608
be issued only from the Primary FCS switch. The secpolicyadd command can be issued on all switches for SCC and DCC policies as long to which you want to add members. Valid values for this operand are: • DCC_POLICY_nnn • must be capitalized. 576 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 609
command may be used to manage only SCC, DCC, and FCS policies. Fabric-wide consistence is not supported for AUTH_POLICY, IPF_POLICY and FCS_POLICY. NOTE Back-up FCS switches typically cannot modify the policy. However, if Primary FCS switch in the policy list is not reachable, then a back-up FCS - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 610
following examples illustrate several ways to specify the port values: (1-6) Selects ports 1 through 6. (*) Selects all ports on the switch. [3, 9] Selects ports 3 and 9 and all , secPolicyDump, secPolicyRemove, secPolicySave 578 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 611
each have a unique name. This command can be issued on all switches in the current fabric for SCC and DCC policies if it is of a policy you want to create. Valid values for this operand are: • DCC_POLICY_nnn • • IPF_POLICY • FCS_POLICY Fabric OS Command Reference Manual 579 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 612
characters do not have to be capitalized like regular policy names. Valid values for DCC_POLICY_nnn are user defined alphanumeric or underscore characters. The maximum length is 30 characters, including the prefix DCC_POLICY_. When the switch is in non-secure mode this command can be used to manage - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 613
the command fails. To add all switches in the current fabric as members of the SCC_POLICY, enter an asterisk (*) as the member value. This feature cannot be used by secPolicyDelete, secPolicyDump, secPolicyRemove, secPolicySave, secStatsShow Fabric OS Command Reference Manual 581 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 614
when FCS policy is enabled on the switch in base FOS, this command can be issued only from the Primary FCS switch. Operands This command has the following operands fabric-wide switch access through that method is unrestricted. Examples To delete an existing security policy: switch:admin> - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 615
secPolicyDelete 2 See Also Are you sure (yes, y, no, n):[no] y MS_POLICY has been deleted. secPolicyAbort, secPolicyActivate, secPolicyAdd, secPolicyCreate, secPolicyDump, secPolicyRemove, secPolicySave, secPolicyShow Fabric OS Command Reference Manual 583 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 616
mode is enabled, this command can be issued from all the FCS switches in the fabric. Operands This command has the following operands: "listtype" a security policy you would like to display. Valid values for this operand are: • DCC_POLICY_nnn • FCS_POLICY • Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 617
.13 192.155.52.11 ACTIVE POLICY SET TELNET_POLICY IpAddr 192.155.52.0 secPolicyAbort, secPolicyActivate, secPolicyAdd, secPolicyCreate, secPolicyDelete, secPolicyRemove, secPolicySave, secPolicyShow Fabric OS Command Reference Manual 585 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 618
values for the operands. If a backup FCS is moved to the first position, it becomes the primary FCS after activation. This command can be issued in secure mode from the Primary FCS switch.It is supported , secPolicySave, secPolicyShow 586 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 619
, this command can be issued only from the primary FCS switch. Operands This command has the following operands: "name" Specify members from. Valid values for this operand be specified using IP address, WWN, domain, or switch name. IP Address Member Policy Types The following policy - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 620
switch names. If domain or switch names are used, the switches switch and port combination must be specified in the following format: can be specified using WWN, domain, or switch values: (1-6) Selects ports 1 through 6. (*) Selects all ports on the switch switch switch: - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 621
secPolicySave, secStatsShow secPolicyRemove 2 Fabric OS Command Reference Manual 589 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 622
switch. This command is always a local switch operation. When secure mode is enabled, this command saves Defined Security Policy to persistent memory on all switches in the fabric and can be issued only from the primary FCS switch. NOTE persistent memory: switch:admin> secpolicysave - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 623
database in effect on all the FCS switches in the fabric and can be issued from all FCS switches. In non-secure mode, this command policy_type" Specify which policy to display, in quotation marks. Valid values are "Active", "Defined", or "*" for both Active and Defined Manual 591 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 624
192.155.52.0 See Also To display all security policies from defined databases: switch:admin> secpolicyshow "defined DEFINED POLICY SET FCS_POLICY Pos Primary WWN DId swName 1 , secPolicyDump, secPolicyRemove, secPolicySave 592 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 625
switches in the fabric. Operands This command has the following operands: "name" Specify the name of a security statistic you would like to reset. If executed on the primary FCS, specify an asterisk (*) to represent all security policies. Valid values Command Reference Manual 593 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 626
is optional and the default value is the local switch. Examples To reset all statistics on the local switch: switch:admin> secstatsreset About to : switch:admin> secstatsreset "DCC_POLICY", "1;69" Reset DCC_POLICY statistic. secFabricShow, secStatsShow 594 Fabric OS Command Reference Manual 53 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 627
issued to any switch. If issued on the primary FCS switch, this command can retrieve and display the security statistics for any or all switches in the fabric to represent all security policies. Valid values for this operand are: TELNET_POLICY HTTP_POLICY Reference Manual 595 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 628
separated by semicolons. This operand is optional and the default value is the local switch. Examples To display the MS_POLICY statistics on the local switch: switch:admin> secstatsshow "MS_POLICY" Name Value MS 20 See Also To display statistic information for TELNET_POLICY for all - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 629
from the primary FCS switch. Operands This command has the following operands: domain Specify the domain of the switch from which the temporary passwords are to be removed. Passwords of all permanent accounts have been reset to fabric-wide values. Root and factory accounts on each Non FCS switch - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 630
remote switch root password: Re-type new password: Login sessions with password changed will be terminated. Password successfully set on domain 2 for root See Also passwd, secModeDisable, secModeEnable, secModeShow, secNonFCSPasswd, secTempPasswdReset 598 Fabric OS Command Reference Manual 53 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 631
from management application problems. This command switch:admin> sectransabort Transaction has been aborted. See Also secPolicyAbort, secPolicyActivate, secPolicyAdd, secPolicyCreate, secPolicyDelete, secPolicyDump, secPolicyRemove, secPolicySave, secStatsShow Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 632
to 0: switch:admin> secversionreset About to reset version stamp to 0. Are you sure (yes, y, no, n):[no] y done. Security Policy Version Stamp has been set to 0. See Also secFabricShow, secModeDisable, secModeEnable, secModeShow, secTransAbort 600 Fabric OS Command Reference Manual 53-1000436 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 633
To view all sensor values: switch:admin> sensorshow sensor 1: (Temperature) is Ok, value is 39 C sensor Power Supply ) is Ok sensor 11: (Power Supply ) is Absent sensor 12: (Power Supply ) is Ok sensor 13: (Power Supply ) is Absent See Also fanShow, tempShow Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 634
default, no debug messages are displayed. High debug level values can generate a large volume of messages, degrading the system response time. The set of supported value (default) specifies that no messages are to display. Higher values NS to value 3: switch:admin> setdbg NS 3 switch:admin> dbgshow - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 635
or disable ESD mode. The mode is saved in flash memory and stays in that mode until the next blade in a Brocade chassis; however, the command is not supported by the Brocade platform and does specified, the current value displays. Examples To display the ESD mode: switch:admin> setesdmode - - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 636
if the mode value is nonzero and disable the media mode if the mode value is 0. The mode is saved in flash memory and stays switch:admin> setgbicmode 1 GBIC mode is now 1 (Enabled). See Also itemList, miniCycle, setMediaMode, setSfpMode, spinJitter, spinSilk 604 Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 637
if the mode value is nonzero and disable the media mode if the mode value is 0. The mode is saved in flash memory and stays switch:admin> setmediamode -show Media mode is now 0 (disabled). See Also itemList, miniCycle, setGbicMode, setSfpMode, spinJitter, spinSilk Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 638
setmodem [-e] | [-d] Description Use this command to enable or disable modem dial-in to a CP on those systems that support modem dial-in. When modem dial-in is enabled, you can log in to a CP through a modem, and in to the standby CP. . . . 606 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 639
; RS-232 port interface) POWER SUPPLY 4 RS - 232 RS - 232 IOIOI IOIOI Link 10/100 Mb/s Active CP Link 10/100 Mb/s Active CP switch:admin> setmodem -d disabling modem, please wait, this can take a couple of minutes... modem disabled See Also none 2.015 Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 640
if the mode value is nonzero and disable the media mode if the mode value is 0. The mode is saved in flash memory and stays switch:admin> setsfpmode 0 SFP mode is now 0 (disabled). See Also itemList, miniCycle, setGbicMode, setMediaMode, spinJitter, spinSilk 608 Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 641
is 0. The mode is saved in flash memory and stays in that mode until internal switch problems from SFP problems since a Brocade chassis; however, the command is not supported by the Brocade platform mode is specified, the current value is displayed. This operand is switch:admin> setsplbmode -show - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 642
filter the display of the debug message to the serial console. By default, no debug messages are displayed. The execution of this command is subject Examples To set the verbose level of module named NS to value 3: switch:admin> setverbose NS 3 switch:admin> dbgshow NS Module NS, debug level = 0, - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 643
a summary of all SFPs in the switch. The summary displays the SFP type mode, this command displays values described in the "Gigabit smart" SFPs, five additional fields display: module temperature, voltage, received optical power, transmitted optical power (longwave only), and laser diode drive - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 644
16: id (sw) Vendor: AGILENT (output truncated) Serial No: 0105091301045274 To display detailed SFP information for a Finisar "smart" SFP: switch Power: 199.6 uWatts TX Power: 235.2 uWatts To display detailed information for GbE port 0 on a Brocade 7500: switch Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 645
Min: 0 Serial No: A00143427 Date Code: 020511 To display all SFP information: switch:user> sfpshow -all Port 0: Identifier: 3 SFP Connector: 7 LC Transceiver: 050c402000000000 100,200_MB/s M5,M6 sw Inter_dist Encoding: 1 8B10B Fabric OS Command Reference Manual 613 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 646
: 0 (units nm) Options: 001a Loss_of_Sig,Tx_Fault,Tx_Disable BR Max: 5 BR Min: 5 Serial No: 21P70530005BW Date Code: 01062301 (output truncated) switchShow 614 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 647
serial ports. Flow control is disabled by default. Because this command changes the flow control the configuration database; therefore, persistent across reboots and power cycles. On dual control processor (CP) systems, To disable flow control: switch:admin> shellflowcontroldisable Disabling - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 648
task. Flow control is disabled by default. Because this command changes the database; therefore, persistent across reboots and power cycles. On dual control processor (CP) an extended period of time, the switch might reboot. It is recommended to flow control: switch:admin> shellflowcontrolenable - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 649
. Description This command is not supported on this platform as of FOS 5.1 - use slotPowerOff. The execution of this command is subject to Admin Domain restrictions that may be in place. See Also slotShow, slotPowerOff, bladeDisable Fabric OS Command Reference Manual 617 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 650
slotPowerOn. Description This command is not supported on this platform as of FOS 5.1 - use slotPowerOn. The execution of this command is subject to Admin Domain restrictions that may be in place. See Also slotShow, slotPowerOn, bladeEnable 618 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 651
Specify the slot number of the blade to be powered down. This operand is required. Examples To power off blade unit 3: switch:admin> slotpoweroff 3 Slot 3 is being powered off See Also powerOffListSet, powerOffListShow, slotPowerOn, slotShow Fabric OS Command Reference Manual 619 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 652
the blade unit must be currently powered off. The slotShow command reports such slots as being in the state of INSERTED, NOT POWERED ON. The execution of this command blade to be powered on. This operand is required. Examples To power on blade unit 3: switch:admin> slotpoweron 3 Powering on slot 3. - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 653
processor blade 17 FC4-16 port blade 18 FC4-32 port blade 24 FR4-18i port blade 31 FR4-16IP port blade 33 FA4 -16 port blade 36 FR4-48 port blade 39 FC10-6 port blade Status Displays the status of the blade: VACANT The slot is empty. INSERTED, NOT POWERED ON The blade - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 654
using bladeDisable. DISABLED The blade is powered on but disabled. FAULTY The status of all slots in the system: switch:user> slotshow Slot Blade Type ID Status 16 ENABLED 6 CP BLADE 16 ENABLED 7 AP BLADE 24 LOADING 8 SW BLADE 17 DIAG RUNNING POST1 9 SW BLADE 17 INSERTED, NOT POWERED - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 655
the intended functional operation of the switch by sending SERDES BIST patterns ports are marked bad. This command is supported only on Brocade 200E, 4100, and 48000 platforms. The to 4 GBit/sec (default) -ports itemlist Specifies a list of blade ports to test. By default, all the blade ports - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 656
Refer to itemList for further details. Examples To test the serial link of the following port path: switch:admin> sltest -ports 0/5-0/31 -speed 4 -lb_mode 1 passcnt 1 Running Port sltest .... passed. , itemList, portRegTest, spinSilk 624 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 657
supports set, reset to default, and display operations. Issue this command with incomplete parameters and it displays the command usage. All values successfully changes by this command take effect immediately and are persistent across power cycles 2 to 16 characters. The default values for the - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 658
of three entries of role snmpadmin and three entries of role snmpuser are supported. Separate default passwords are provided for creation of authKey and privKey for each entry. Default set of passwords are published and default algorithm (MD5/SHA) is used to create initial set of auth keys. You - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 659
by comparing nonzero IP octets. For example, an ACL of 192.168.64.0 enables access by any hosts that start with the specified octets. The can receive FA-TRAPS from the switch. The default value is yes. Users can also turn The default value is 'no'. Fabric OS Command Reference Manual 627 53-1000436 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 660
default value is set as Fibre Channel Switch. The location of the system (switch). The default value is set as End User Premise. The contact information for this system (switch). The default value is set as Field Support user name, authentication protocol and password, SNMPv3 trap recipients IP - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 661
yet To set the SNMPv1 configuration of a switch: switch:admin> snmpConfig --set snmpv1 SNMP community and 16 - please re-enter Community (rw): [OrigEquipMfr] Trap Recipient's IP address: [1080::8:800:200C:1230] 10.32.147. notation: [0.0.0.0] Fabric OS Command Reference Manual 629 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 662
agtCfgDefault, agtCfgSet, agtCfgShow, snmpMibCapSet, snmpMibCapShow SW_v5_x.mib, "Switch Management Information & Switch Enterprise Specific Trap" RFC1157, "A Simple Network Management Protocol of the Simple Network Management Protocol (SNMPv3)" 630 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 663
default value is yes. SW-TRAP Specifying yes means the SNMP management application can receive SW-TRAPS from the switch. The default value See the Fabric OS MIB Reference Manual for more information. The execution : switch:admin> snmpmibcapset The SNMP Mib/Trap Capability has been set to support FE - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 664
] HA-TRAP (yes, y, no, n): [yes] fruStatusChanged (yes, y, no, n): [yes] cpStatusChanged (yes, y, no, n): [yes] fruHistoryTrap (yes, y, no, n): [no] agtCfgDefault, agtCfgSet, agtCfgShow 632 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 665
FA-TRAP Specifying yes means the SNMP management application can receive FA-TRAPS from the switch. The default value is yes. Users can also turn on or off individual FA Traps. The individual not prompt the user to turn on or off these MIBs. Fabric OS Command Reference Manual 633 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 666
may be in place. Operands none Examples To display the options for configuring the SNMP MIB capability: switch:admin> snmpmibcapshow FE-MIB: YES SW-MIB: YES FA-MIB: YES FICON-MIB: NO HA-MIB agtCfgDefault, agtCfgSet, agtCfgShow, snmpConfig 634 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 667
switches that support trunking, then it is likely that trunk groups are present and all ports between the two switches port. The default value is 10 default, all of the ISL ports in the current switch will be tested. Refer to itemList help pages for further details. Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 668
2 spinFab -setfail mode Instruct spinFab how to mark failed ports. If , this might be useful with large values of -nmegs count. This mode is disabled by default. Examples To test cascading ISL links: switch:admin> spinfab -ports 1/0 - 1/2 636 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 669
See Also camTest, centralMemoryTest, cmemRetentionTest, cmiTest, itemList, portLoopbackTest, spinSilk, sramRetentionTest spinFab 2 Fabric OS Command Reference Manual 637 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 670
procedures used in this test, refer to spinSilk. The command is supported only on Brocade 200E, 3250, 3850, 3900,4100, 24000, and 48000 platforms; use frames transmits on each port. The default value is 10, which represents 10 million frames. -lb_mode mode Selects OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 671
2 Gbit/sec. -ports itemlist Specifies a list of user ports to test. By default, all the user ports in the specified slot (--slot) will be used. Refer to further details. Examples To measure line-speed jitter: switch:admin> spinjitter -ports 1/0 - 1/2 Running SpinJitter Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 672
the Fabric OS Message Reference for more information. See Also backport, camTest, centralMemoryTest, cmemRetentionTest, cmiTest, itemList, portLoopbackTest, portRegTest, spinSilk, sramRetentionTest 640 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 673
on next blade, where applicable (0-16, 0-32, and so forth). An error default) are selected, you must have the appropriate termination on all tested ports. If not, the ports without the correct termination do not achieve synchronization and the test fails. The command is supported only on Brocade - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 674
spinSilk, can be used to determine which components of the switch are faulty. The execution of this command is subject to have been transmitted on some ports, but not less. The default value is 10, so the number of frames sent will be at least 642 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 675
/sec; set all odd ports' speed to 2 Gbit/sec. Specify a nonzero value to display more detailed information during the test. This mode should be used for list of user ports to test. By default, all of the user ports in the current switch are tested. Refer to itemList for Manual 643 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 676
the Fabric OS Message Reference for more information. See Also backport, camTest, centralMemoryTest, cmemRetentionTest, cmiTest, itemList, portLoopbackTest, portRegTest, spinJitter, sramRetentionTest 644 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 677
data retention test -delay value Specify the delay between the read and write, in seconds. The default value is 10 seconds. Examples To run a data retention test: switch:admin> sramretentiontest 2 Running SRAM Retention Test ... passed. Fabric OS Command Reference Manual 645 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 678
Refer to the Fabric OS Message Reference for more information. See Also camTest, centralMemoryTest, cmemRetentionTest, cmiTest, dataTypeShow, itemList, portLoopbackTest, spinSilk 646 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 679
statistics for the blade ports specified in -bports clears; otherwise, the user ports specified in -uports clears. The default value is 0. Examples To clear port and diagnostic statistics: switch:admin> statsclear -bports 1/10-1/62 -use_bports 1 See Also itemList Fabric OS Command Reference - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 680
switch using the switchDisable command. There is a link table that stores 16 pairs of SID-DID address. Each of the SID-DID pairs is named a link. This table is used for gathering statistics that match the link. This command is supported only on Brocade . The default value is 1. Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 681
See Also camTest, itemList statsTest 2 Fabric OS Command Reference Manual 649 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 682
Domain restrictions that may be in place. Operands This command has the following operand: -ports itemlist Specify a list of user ports to test. By default, all the user ports in the switch are tested. Refer to itemList help pages for further details. Examples To stop the portTest command - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 683
when a message with FFDC attributes is logged. FFDC is enabled by default. The execution of this command is subject to Admin Domain restrictions that configuration: switch:admin> supportffdc --show First Failure Data Capture (FFDC) is disabled. To enable the FFDC events: switch:admin> supportffdc - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 684
][-p password][-d remotedirectory] supportftp -t hours supportftp -R supportftp -e Description Use this command to set, clear, or display support FTP is not specified, the supportFtp command defaults to supportFtp -S. Examples To set the FTP parameters: switch:admin> supportftp -s -h 192.168 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 685
:admin> supportftp -s Host IP Addr[1080::8:800:200C:417A]: User Name[njoe]: Password[********]: Remote Dir[support]: Auto file transfer parameters changed To display a time interval to check the FTP server: switch:admin> supportftp -t 24 supportftp: ftp check period changed. To enable auto file - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 686
core files and panic dumps remain on the switch after the command.The FFDC data will be removed after the command. If there are BP blades installed in the switch, it will also retrieve support only core and used. -p password Specifies the password for the mode services. Because the - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 687
MB 1.35 MB/s Saving support information for switch:routing1, module:Zone_Log... ...upportSave_files/routing1-S6-200508280207-Zone_Log.ss: 27.71 kB kB/s 9.23 Saving support information for switch:swd76, module:Zone_Log... /tmp/supportSave_files/swd76-S6-200508280207-Zone_Log.ss: 48.16 kB kB/s 16 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 688
There will be two trace dump files transfered after this command. OK to proceed? (yes, y, no, n): [no] Host IP: 192.168.1.1 User Name: admin Password: ***** Remote Directory: tmp Saving support information for switch:routing1, module:RASLOG... 656 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 689
MB 1.35 MB/s Saving support information for switch:routing1, module:Zone_Log... ...upportSave_files/routing1-S6-200508280207-Zone_Log.ss: 27.71 kB kB/s 9.23 Saving support information for switch:swd76, module:Zone_Log... /tmp/supportSave_files/swd76-S6-200508280207-Zone_Log.ss: 48.16 kB kB/s 16 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 690
support. Refer to "supportShow Reference", for more information. The commands have been arranged in groups identified as follows: OS (ENABLED by default /meminfo various proc entries find core files exception (ENABLED by default) errDump pdShow port (ENABLED by default) diagShow (per-slot) portShow - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 691
mergeshow zone stateshow services (ENABLED by default) fdmiCacheShow fdmiShow nsShow nsAllShow nscamShow nscamShow -t ns portshow security (ENABLED by default) authUtil authUtil -dump -a secFabricShow secGlobalShow secModeShow secPolicyDump secStatsShow Fabric OS Command Reference Manual 53-1000436 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 692
df ifconfig route hostname portlog (ENABLED by default) portLogDump system (ENABLED by default) myId version firmwareShow upTime switchStatusShow switchShow haDump emtraceshow2 emhsmtraceshow systraceshow -d fwAlarmsFilterShow chassisShow timeout 660 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 693
switchrnid ficucmd dump -A FC-FC Routing (DISABLED by default) fcrProxyDevShow fcrProxyConfig fcrXlateConfig fcrPhyDevShow fcrRouteShow fcrFabricShow fcrResourceShow FCIP (DISABLED by default) portShow fciptunnel ge$k all Fabric OS Command Reference Manual 53-1000436-01 supportShow 2 661 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 694
switch:admin> supportshow 1/1-3 supportshow groups enabled: system version: Kernel: 2.4.19 Fabric OS: v4.1.0 Made on: Fri Jan 10 01:06:10 2003 Flash: Thu Jan 17 00:06:52 2003 BootProm: 3.2.1 uptime: 10:49am up 3:25, 1 user, load average: 1.55, 1.20 OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 695
supportshowcfgdisable [os | exception | port | fabric | services | security | network | portlog | systemextend | filter the fabric group commands services Disables the service group commands security Disables under the supportShow command: switch:admin> supportshowcfgdisable os Config update - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 696
supportshowcfgenable [os | exception | port | fabric | services | security | network | portlog | system | Enables the fabric group commands services Enables the service group commands security Enables the commands under the supportShow command: switch:admin> supportshowcfgenable os Config update - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 697
Examples To display which groups of commands are enabled in thesupportShow command: switch:admin> supportshowcfgshow os enabled exception enabled port enabled fabric enabled services enabled security enabled network enabled portlog enabled system enabled extend disabled filter - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 698
still executable and functional. The normal flashing LED pattern (associated with an active, value is displayed. Examples To turn beaconing mode on: switch:admin> switchbeacon 1 See Also To turn beaconing mode off: switch:admin> switchbeacon 0 switchShow 666 Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 699
switch. All Fibre Channel ports are taken offline. If the switch was part of a fabric, the remaining switches reconfigure. The switch slow flashing yellow as each port is disabled. A persistently disabled switch can be temporarily enabled using the switchEnable command. A temporarily enabled switch - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 700
switchcfgpersistentenable Description Use this command to persistently enable the switch. All Fibre Channel ports which did not fail power-on self-test (POST) are enabled, and can come online if connected to a device, or remain offline if disconnected. The switch might need to be enabled if it was - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 701
switch to a particular level. The configuration is saved in flash memory and persists across switch reboots or power cycles. If any port on the switch port. This operand is required. Valid values are one of the following: 0 switch: switch:admin> switchcfgspeed 0 Committing configuration...done. See - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 702
a switch. This command requires the Brocade ISL Trunking switch. This operand is required. Examples To enable trunking on a switch: switch:admin> switchcfgtrunk 0 Committing configuration...done. See Also portCfgShow, portCfgTrunkPort, portShow, switchShow 670 Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 703
to be disabled send an error if invoked while the switch is enabled. The switch does not need to be disabled before rebooting or powering off. As each port is disabled, the front panel LED changes to a slow flashing yellow. The execution of this command is subject to Admin Domain restrictions that - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 704
this switch remains the principal switch, then it assigns itself a domain ID. If another switch assumes the principal role, then this switch becomes a subordinate switch and Operands none Examples To enable a switch: switch:admin> switchenable See Also switchCfgPersistentDisable, - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 705
switch name. All switches have a symbolic name that is primarily used for switch management. This name is shown in the Fabric OS CLI prompt, under each switch switch name. Enter this command with no operand to display the current switch name. Changing the switch switch name for the switch. name can - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 706
. This command is not supported on single-domain systems. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To reboot an operational switch: switch:admin> switchreboot Stopping all switch daemons...Done. Powering off slot 1...Done - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 707
display switch and port status information. Information might vary by switch model: for instance, number of ports and domain ID values. For FC routing. The switch summary is followed by one-line description for non-EX_Ports and one or two lines for EX_Ports: Area Part of the 24-bit port ID, which - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 708
Mod_Val Mod_Inv No_Light No_Sync In_Sync Laser_Flt Port_Flt Diag_Flt Lock_Ref Testing Offline Online The 24-bit Address Identifier. Address column is only displayed for slot-based platforms. Media types ports only). Port is up and running. 676 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 709
is between a Brocade 48000 and a Brocade 4100 or 200E, the disabled E_Port displays as No_Sync. NOTE On a Brocade 7600 switch, if the SAS image is not consistent with the FOS image, "(SAS Virtualization Disabled)" will appear at the end of the output. Fabric OS Command Reference Manual 677 53 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 710
in a switch. Examples To display the port count: switch:admin> switchshow -portcount ports= 64 To display GE ports with iSCSI sessions: switch:admin> switch attached to this N_Port as a 24-bit Port Identifier assigned to this port by the enterprise fabric. To display switch information: switch - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 711
035f00 id N2 Online 10:00:00:00:00:02:00:00 208 8 16 03d000 -- -- Offline [output truncated] 216 8 24 03d800 -- -- Online a switch in Access Gateway mode: switch:admin> switchName: switchType: switchState: switchMode: switchWwn: switchBeacon: switchshow switch 34.0 Manual 679 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 712
switchShutdown Not supported on this platform. Synopsis Description switchshutdown This command is not supported on this platform as of FOS 5.1. The execution of this command is subject to Admin Domain restrictions that may be in place. 680 Fabric OS Command Reference Manual 53-1000436 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 713
switchStart Not supported on this platform as of Fabric OS 5.1. switchStart 2 Fabric OS Command Reference Manual 681 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 714
1 WWN 0 1 CP 0 1 Blade 0 1 Flash 0 1 MarginalPorts 2 1 FaultyPorts 2 1 MissingSFPs 0 0 Any single contributor can force the overall status of the switch to MARGINAL or DOWN. For example, assuming that the switch contributor values are set to the default values, if there is one - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 715
0 1 Flash 0 1 MarginalPorts 2 1 FaultyPorts 2 1 MissingSFPs 0 0 Note that the value, 0, for a parameter, means that it is NOT used in the calculation. ** In addition, if the range of settable values in the ** prompt is (0..0), the policy parameter is NOT applicable ** to the switch. Simply - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 716
differ from platform to platform. TABLE 19 Default Contributor, Values, and Status Contributor DOWN Default MARGINAL Default PowerSupplies 2 1 Temperatures 2 1 Fans 2 1 WWN 0 1 CP 0 1 Blade 0 1 Flash 0 1 MarginalPorts 2 1 FaultyPorts 2 1 MissingSFPs 0 0 The policy - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 717
MissingSFPs 0 0 See Also switchStatusPolicySet, switchStatusShow switchStatusPolicyShow 2 Fabric OS Command Reference Manual 685 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 718
Health Report Report time: 09/11/2006 05:39:28 PM Switch Name: switch IP address: 1080::8:800:200C:417A SwitchState: MARGINAL Duration: 80:12 Power supplies monitor Temperatures monitor Fans monitor Flash monitor Marginal ports monitor Faulty ports monitor Missing SFPs monitor HEALTHY - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 719
with an IPv4 address: switch:user> switchstatusshow Switch Health Report Switch Name: switch IP address: 10.32.89.26 SwitchState: MARGINAL Duration: 80:12 Report time: 09/11/2006 05:39:28 PM Power supplies monitor Temperatures monitor Fans monitor Flash monitor Marginal ports monitor - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 720
. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To view the uptime for the switch: switch:user> switchuptime 9:50pm up for 20 mins See Also switchReboot, switchShutdown 688 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 721
forwarding messages to the servers added through the command syslogdIpAdd. The default facility is LOG_LOCAL7. The execution of this command is subject to is displayed. Examples To set the syslog facility to LOG_LOCAL1: switch:admin> syslogdfacility -l 1 Syslog facility changed to LOG_LOCAL1 See - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 722
are configured, the switch forwards all error log entries to the syslogd on the specified server(s). Up to six servers are supported. The syslogdipadd command the list of machines to which system messages are sent: switch:admin> syslogdipadd 1080::8:800:200C:417A See Also errShow, syslogdFacility - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 723
syslogd. This operand is required. Examples To remove the address 1080::8:800:200C:417A from the list of machines to which system messages are sent: switch:admin> syslogdipremove 1080::8:800:200C:417A See Also errShow, syslogdFacility, syslogdIpAdd, syslogdIpShow Fabric OS Command Reference - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 724
subject to Admin Domain restrictions that may be in place. Operands none Examples To display all syslog daemon IP addresses: switch:admin> syslogdipshow syslog.IP.address.1 1080::8:800:200C:417A See Also errShow, syslogdFacility, syslogdIpAdd, syslogdIpRemove 692 Fabric OS Command Reference - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 725
system. For Brocade directors, when sysShutdown is called in the active control processor (CP), the command shuts down the active CP, standby CP, and any AP blades. After doing this, you need to manually power off the system. If you want to reboot the system, manually turn the power switch on. This - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 726
This command will shutdown the operating systems on your switch. You are required to power-cycle the switch in order to restore operation. Are you sure you want to shutdown the switch [y/n]? y This is the active Cp 2005/11/16-05:47:20, [FSSM-1003], 5641,, WARNING, Brocade12000, HA State out of - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 727
port-count products, the slot defaults to 0. The command monitors are designed to operate with switches connected to a fabric previously stored values. This shorter test cycle does not only BLADE is supported at this time. Since only one FRU type is supported, this parameter Manual 695 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 728
To initiate a system verification test on all switches in the fabric: switch:admin> systemverification -short systemverification: Setting parameters for short run. systemverification: burnin parameters. CURRENT - KEYWORD : DEFAULT 1 - number_of_runs : 1 2 - vib : 2 10 - thermal : 10 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 729
), the sensor state, and the temperature. The temperature readings are given in both Centigrade and Fahrenheit. Refer to the hardware reference manual for your switch to determine the normal temperature range. The execution of this command is subject to Admin Domain restrictions that may be in place - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 730
value to the specified interval. A value of 0 disables timeout functionality of login sessions. The new timeout value of minutes for the telnet timeout value. Valid values are 1 to 99,999, or displays the current timeout value. Examples To set the idle timeout to 10 minutes: switch:admin> timeout 10 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 731
to display the fabric topology, as it appears to the local switch, including: A list of all domains that are part of bandwidth that is less than 0.512 Gbit/sec is adjusted to the nearest power of 2 value, while a bandwidth that is ranged from 0.512 Gbit/sec (included) to Manual 699 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 732
by port: 5 Local Translate Domain 8 owned by port: 4 Domain: 6 Metric: 500 Name: switch Path Count: 4 Hops: Out Port: In Ports: Total Bandwidth: Bandwidth Demand: Flags: 1 60 D See Also fcrXlateConfig, portRouteShow, uRouteShow 700 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 733
the dump status on the switch. If there is no parameter specified, this command defaults to traceDump -S. The default remote file name format is hour-minute-second) is the trace dump time. If non-blade system has an embedded BP, two trace dumps will be generated, one with .dmp for the main switch - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 734
is subject to Admin Domain restrictions that may be in place. Examples To display information on the track-changes commands: switch:admin> trackchangeshelp trackChangesSet Configure alert for login/logout/config update trackChangesShow Displays status of track changes See Also trackChangesSet - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 735
dumped to the error log for the switch. Use errDump or errShow to view or 0 to disable the feature. The default (if no operand is specified) is the SNMP-TRAP messages. The default (if no operand is specified) is switch:admin> trackchangesset 1, 1 Committing configuration...done. switch - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 736
output from the track-changes feature is dumped to the error log for the switch. Use the errDump command or errShow command to view the error log. The Examples To display the status of the track-changes feature: switch:admin> trackchangesshow Track changes status: ON Track changes generate SNMP - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 737
Switch does not support trunking Trunking license required Trunking not supported in switch port port_id connect to different switches port port_id and port port_id connect to the switch WWN port port_id is connection: switch:admin> trunkdebug 43 44 Switch does not support trunking switch:admin> - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 738
WWNs of the remote switches. See EXAMPLES, below. deskew The time difference for traffic to travel over each ISL compared to the time to the shortest ISL in the group. The number corresponds to nanoseconds divided by 10. The firmware automatically sets the minimum deskew value of the shortest ISL - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 739
68-> 23 10:00:00:05:1e:37:12:13 64-> 16 10:00:00:05:1e:37:12:13 65-> 19 10:00:00:05:1e:37:12:13 4 deskew 17 MASTER 4 deskew 16 4 deskew 16 4 deskew 16 4 deskew 17 4 deskew 17 4 deskew 15 4 deskew 16 switch:admin> switchshow 48 4 0 013000 id N4 Online EX-Port - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 740
switch (when the security feature is enabled) connect to the NTP server and broadcast time service updates. All switches in the fabric maintain the current clock server IP address in flash memory. By default, this value that an NTP server that supports a full NTP client be used. The - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 741
See Also Updating Clock Server configuration...done. switch:admin> tsclockserver 123.123.123.123 date tsClockServer 2 Fabric OS Command Reference Manual 709 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 742
way. System services started during the switch boot reflect time-zone change only at the next reboot. The time zone can be specified either by name or an older hours and minutes format. The older format is specified with the --old option. It only allows a subset of values for the hours and minutes - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 743
default switch:admin> tstimezone Time Zone Hour Offset: 0 Time Zone Minute Offset: 0 switch next reboot. switch:admin> tstimezone Time Zone Hour Offset: -3 & Barbuda 19) El Salvador 36) Peru 3) Argentina 20) French Guiana 37) Cuba 32) Netherlands Antilles 49) Virgin Islands (US) 16) Dominica - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 744
Idaho & east Oregon 16) Mountain Time - Navajo 17) Mountain Standard Time - Arizona 18) Pacific Time 19) Alaska Time 20) Alaska Time - switch admin> tstimezone --old 2 switch admin> tsttimezone Time Zone Hour Offset: 2 Time Zone Minute Offset: 0 See Also date 712 Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 745
value is 1. -ports itemlist Specifies a list of blade ports to test. By default, all the blade ports in the specified slot are tested. Refer to the itemList command help page for more information. Examples To execute this test: switch Fabric OS Command Reference Manual 713 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 746
paths between the chips within a mini-switch. This is done by configuring all of the ports on the mini-switch in internal loopback and sending a frame from the first seven frames use unique data type. This command is supported only on Brocade 200E,3250, 3850, 3900,4100, 24000, and 48000 platforms; - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 747
first error. The default value is 0. -ports itemlist Specify a list of user ports to test. By default, all of the user ports in the current switch are tested. This option can be used to restrict testing to the specified ports. To run the txdPath test: Fabric OS Command Reference Manual 715 53 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 748
2 txdPath switch:admin> txdpath Running TX Data Path Test .... Test Complete: "txdpath" Pass 10 of 10 Duration 0 hr, , camTest, centralMemoryTest, cmemRetentionTest, cmiTest, itemList, portLoopbackTest, portRegTest, spinSilk, sramRetentionTest 716 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 749
system load averages for the past 1, 5, and 15 minutes. For up and powered-on times less than 60 seconds, the time is displayed in seconds. For none Examples To display the length of time the system has been operational: switch:admin> uptime 12:03am up 4:56, 3 users, load average: 1.17, - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 750
static routes, load sharing might be affected. The switch attempts to achieve optimum load sharing, but if too configuration is not supported on Brocade directors set to chassis to domain 2 to go through port 5: switch:admin> urouteconfig 1 2 5 done. switch:admin> urouteshow 1/1 2 Local Domain ID: - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 751
the destination domain of the static route to remove. Examples To remove a static route for all traffic coming in from port 1 and addressed to domain 2: switch:admin> urouteremove 1 2 done. See Also configShow, dlsShow, uRouteConfig, uRouteShow Fabric OS Command Reference - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 752
(PID Format 2) on a switch, the value is equal to the Area field displayed by the switchShow command. Refer to Fabric OS Administrator's Guide for more information regarding the extended routing information for all input ports in the switch. 720 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 753
of port 11 to domain 4 only: switch:admin> urouteshow 1/11, 4 Local Domain ID: 3 In Port Domain Out Port Metric Hops Flags Next (Dom, Port) 11 4 16 500 1 D 4,16 See Also portRouteShow, topologyShow, uRouteConfig, uRouteRemove Fabric OS Command Reference Manual 721 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 754
command to add, delete, change or recover accounts are allowed only on the Primary FCS switch. The Primary FCS switch distributes the update to the entire Fabric. As a result, all switches supporting customer-defined accounts will have the same account database. All accounts that are not consistent - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 755
switch, with the assigned role of rolename. Valid values an additional valid value of NonFCSAdmin. an expired password that must be changed the first prompts for an initial password. There can be a named username from the switch. This action does You cannot delete any default account. You cannot - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 756
any default switch-local user database only, regardless of whether the switch is configured to use RADIUS authentication or not. Examples To add a new account: switch:admin> userconfig --add joe -r admin -d "Joe Smith" Setting initial password for joe 724 Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 757
Date: Not Applicable Locked: No AD membership: 0 Home AD: 0 To change account attributes: switch:admin> userconfig --change joe -e no Broadcast message from root Sat Apr 2 03:03:32 2005... Security Policy, Password or Account Attribute Change: joe will be logged out Attribute for account joe has - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 758
rename the admin-level login name to the Brocade-specific default of admin and the user-level login name to the Brocade-specific default of user before enabling security; otherwise, the switch is not allowed in the secure fabric. This command is not supported on all platforms. The execution of this - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 759
build date of firmware running in switch Flash Displays the build date of firmware stored in flash proms BootProm Displays the version of the firmware stored in the boot PROM Usually the Made on and Flash dates are the same, because the switch starts running flash firmware at power-on. However - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 760
you to reboot the system (or switch on dual-domain systems), because the change does not take effect until the switch restarts. This reboot can be deferred, or reboot to propagate the change to all switch components. However, the restart of the switch must happen before any firmwareDownload or (for - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 761
zone_object"] Lists all zone members that are not part of the current zone enforcement table. If a switch is specified using D,P in the Admin Domain membership list, all zone elements specified with WWNs associated zone database are validated. Fabric OS Command Reference Manual 729 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 762
zone database. This is the assumed default mode flag value if no mode flag is specified. switch:admin> zone --copy AD0.cur_cfg1 To copy backup_zn zone from the root zone database (AD0) to the current Admin Domain: switch:admin> zone --copy AD0.backup_zn 730 Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 763
switch:admin> zone --expunge "100,5" To delete all reference of zone backup_zn: switch:admin> zone --expunge backup_zn To delete all reference of zone alias backup_ali1: switch : switch:admin> zone --validate -m 0 To validate all zones in the zone database in the persistent storage: switch:admin - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 764
. Valid values can be one or more of the following: A switch domain and port area number pair; for example, "2, 20". View arrays to "Blue_zone": sw5:admin> zoneadd "Blue_Zone", "array3; array4; array5" See Also zoneCreate, zoneDelete, zoneRemove, zoneShow 732 Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 765
semicolons. Specify ports by domain and port area number. The values are entered as a pair of numbers "s,p" where "s" is the switch number (domain ID) and "p" is the port area number. For example, "2, 20" specifies port area number 20 on switch domain 2. When a zone member is specified by port area - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 766
used for any other zone object. Zone names are limited to 64 characters. "member" List of members to be included in zone, of the following: A switch domain and port area number pair: for example, "2, 20". View the area numbers for , zoneShow 734 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 767
to be preserved across switch reboots, it must be saved to flash memory using the cfgSave Brocade Advanced Zoning license. When secure mode is enabled, this command can be issued only from the primary FCS switch delete the zone "Blue_zone": switch:admin> zonedelete "Blue_zone" See Also - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 768
restrictions that may be in place. Operands none Examples To display zone command help information: switch:admin> zonehelp aliAdd aliCreate aliDelete aliRemove aliShow Add a member to a zone alias Create transaction See Also none 736 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 769
command for more information on name and member specifications. This command requires a Brocade Advanced Zoning license. When secure mode is enabled, this command can be issued only from the primary FCS switch. Operands This command has the following operands: "objectName" The name of the - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 770
a Brocade Advanced Zoning license. When secure mode is enabled, this command can be issued only from the primary FCS switch. Operands :20:37:0c:76:22; 21:00:00:20:37:0c:76:28 alias: loop1 21:00:00:20:37:0c:76:85; 21:00:00:20:37:0c:71:df switch:admin> zoneobjectexpunge "White_zone" switch:admin - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 771
command for more information on name and member specifications. This command requires a Brocade Advanced Zoning license. When secure mode is enabled, this command can be issued only from the primary FCS switch. Operands This command has the following operands: "objectName" The name of the - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 772
requires a Brocade Advanced Zoning license. When secure mode is enabled, this command can be issued only from the primary FCS switch. Operands can be one or more of the following: A switch domain and port area number pair: for example, enter "2,20" to view the area numbers for ports using the - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 773
), or specify 1 to display the contents of the nonvolatile memory. The default value is 0. This operand is optional. Examples To display all zones beginning with the letters "A" through "C": switch:admin> zoneshow "[A-C]*" zone: Blue_zone 1,1; array1; 1,2; array2 See Also zoneAdd, zoneCreate - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 774
2 zoneShow 742 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 775
to the Fabric OS Administrator's Guide. Advanced Zoning Commands The following commands are available with the purchase of a Brocade Advanced Zoning license key. TABLE a member from a zone. Displays zone information. Copies a zone object. Fabric OS Command Reference Manual 743 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 776
zone configuration. Saves zone configurations in flash memory. Displays zone configuration information. . Activates or deactivates a default zone configuration, or displays the purchase of a Brocade Advanced Zoning license. supported on Fabric OS v4.x or v5.x. 744 Fabric OS Command Reference - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 777
the port information for specified user ports. Displays switch availability monitor information. Sets the parameters controlled by Fabric Watch. Sets boundary and alarm levels to custom values. Sets boundary and alarm levels to the default values. Displays the thresholds monitored by Fabric Watch - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 778
detailed information about trunking refer to the Fabric OS Administrator's Guide. TABLE 5 Brocade Trunking Commands Command Description portCfgTrunkPort switchCfgTrunk trunkDebug Configures a port for trunking. Configures a switch for trunking. Debugs a trunk link failure. Advanced Performance - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 779
's Guide. TABLE 7 Brocade Secure third-party PKI-based certificates in the switch. Displays the size of the defined security a backup FCS switch to take over as primary FCS switch. Displays the enabled or disabled. Sets the admin password for non-FCS switches. Aborts all changes to the defined - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 780
Brocade Secure an existing policy. Saves a defined security policy to flash memory on all switches in the fabric. Displays an existing security policy. for all policies. Resets a password on a remote switch. Sets a temporary password on a remote switch. Aborts current security transaction. Resets - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 781
primary FCS switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Can be run on all FCS switches. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Fabric OS Command Reference Manual 749 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 782
the primary FCS switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Can also be run on a single non-FCS switch which is segmented from a fabric. Community strings can be changed on the primary FCS switch only 750 Fabric OS Command Reference Manual 53-1000436 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 783
be run from the primary FCS switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Fabric OS Command Reference Manual 751 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 784
4 Commands Exclusive to the Primary FCS 752 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 785
the commands available when logged in to the standby CP in a Brocade 24000 or 48000 director. The full set of commands for your user role are available to the active CP. Commands Supported on the Standby CP The following commands are supported when logged into the standby CP. TABLE 1 Commands - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 786
(CP). supportSave Saves support information for RASLOG, TRACE, and supportShow. switchName Displays this switch's name. tsClockServer Displays time zone. upTime Displays how long switch has been up. version Displays firmware version. 754 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 787
" on page 758 supportShow Control Commands The supportShow command is used to display support information by executing groups of preselected Fabric OS and Linux commands. The information group of commands from displaying under supportShow. Fabric OS Command Reference Manual 755 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 788
portRouteShow fabricShow islShow trunkShow topologyShow fabStateShow fabSwitchShow fabStatsShow fabPortShow fspfShow fcplogshow zone-stateshow portzoneshow portCamShow cfgSize cfgShow rcssmshow rcsinfoshow rcsregistryshow 756 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 789
Command Groups (Continued) Command Group Fabric OS v3.2.0 services nsShow nsAllShow nscamShow security network portlog secModeShow secPolicyDump secStatsShow secFabricShow /bin/df /sbin/ifconfig /sbin/route /bin/hostname portLogDump Fabric OS Command Reference Manual 757 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 790
ptcreditshow ptDataShow ptPhantomShow ptPropShow ptStatsShow filterportshow ps_dump -a -n port# NOTE Many of the commands executed by supportShow are intended for support use only. These commands are not intended for end-users. Proc Entry Information Displayed The os command group prints a number - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 791
: 200MHz revision : 1.69 (pvr 4011 0145) bogomips : 199.47 machine : Brocade Silkworm plb bus clock : 100MHz pci bus clock : 33MHz /proc/devices /proc/ cua 7 vcs 10 misc 89 i2c 90 mtd 128 ptm 136 pts 162 raw 245 swd 246 ham 247 fc 248 fc-switch 249 fabsys 250 fss_kt 251 fss_data 252 fss_mgmt 253 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 792
Active: 23464 kB Inactive: 49472 kB HighTotal: 0 kB HighFree: 0 kB LowTotal: 126700 kB LowFree: 31896 kB SwapTotal: 0 kB SwapFree: 0 kB 760 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 793
: 01000000 00040000 "Entire user flash" mtd3: 00400000 00040000 "kernel Bridge (rev 1). Master Capable. Latency=7. Prefetchable 32 bit memory at 0x0 [0x7fffffff]. Bus 0, device Brocade Communications Systems, Inc. Bloom switch (rev 0). IRQ 26. ---- Fabric OS Command Reference Manual - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 794
113 32 1 1 1 tcp_open_request 0 59 64 0 1 1 inet_peer_cache 1 59 64 1 1 1 ip_fib_hash 11 113 32 1 1 1 ip_dst_cache 65 168 160 7 7 1 arp_cache 2 30 128 1 1 1 blkdev_requests 128 160 96 4 4 1 xfs_chashlist 193 404 16 2 Mar 26 00:04:35 PST 2003 762 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 795
-specific: checks such as whether the command is supported on the platform for which it is targeted, Operator Switch Admin Zone Admin Fabric Admin Basic Switch Admin N O/OM OM N O N O OM O OM O OM O O O O O O O O O O Fabric OS Command Reference Manual 763 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 796
Command Name User Admin Operator Switch Admin Zone Admin Fabric Admin Basic Switch Admin Security Admin aptPolicy auditCfg OM N OM O O OM OM OM N OM O N OM OM/N N N OM OM N N O N N N N N N N N N O O O O O O O O O O O O O N N 764 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 797
Name User Admin Operator Switch Admin Zone Admin Fabric Admin Basic Switch Admin Security Admin chassisShow chipRegShow N OM O N N OM N N N OM N OM O OM O O N OM O N O OM O O N OM O N O OM O O N OM O N Fabric OS Command Reference Manual 765 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 798
User Admin Operator Switch Admin Zone Admin Fabric Admin Basic Switch Admin Security Admin N OM N O N O N O N OM N O N O N O N O N O N O N O N O O OM O O O O O O O O O O O O N O OM O N O N O N 766 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 799
N = none/not available) Command Name User Admin Operator Switch Admin Zone Admin Fabric Admin Basic Switch Admin Security Admin fcpLogClear O OM OM OM N OM O OM OM OM O OM O O firmwareRestore O OM OM OM O OM O O Fabric OS Command Reference Manual 767 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 800
Admin Operator Switch Admin Zone Admin Fabric Admin Basic Switch Admin Security N O N O N O N O OM O N O N O N O N O N O N O N OM OM O O O O O O O O O O O O O O O O OM OM O N O N O N OM OM 768 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 801
User Admin Operator Switch Admin Zone Admin Fabric Admin Basic Switch Admin Security Admin O N O OM O N O N O N O N O N O N OM OM O O O OM O O OM N O O O O O N OM OM OM OM O N O O O N O N O N Fabric OS Command Reference Manual 769 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 802
User Admin Operator Switch Admin Zone Admin Fabric Admin Basic Switch Admin Security Admin O N OM OM O N O N O N O N O N O N O N O N O O N OM OM OM N OM O N O N O N O N O N O N O N O N O N 770 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 803
-modify, N = none/not available) Command Name User Admin Operator Switch Admin Zone Admin Fabric Admin Basic Switch Admin Security Admin perfCfgClear O OM O OM N OM O N perfCfgRestore N portCfgShow O OM OM OM N OM OM N Fabric OS Command Reference Manual 771 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 804
available) Command Name User Admin Operator Switch Admin Zone Admin Fabric Admin Basic Switch Admin Security Admin portCfgSpeed portCfgTrunkPort portcfgvexport portcmd O OM OM N O OM OM OM N OM O N O OM OM OM N OM O N 772 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 805
Command Name User Admin Operator Switch Admin Zone Admin Fabric Admin Basic Switch Admin Security Admin portStatsShow OM N OM O OM O OM O OM O OM O OM OM OM O OM O OM O OM O OM O OM O OM O OM O OM O OM Fabric OS Command Reference Manual 773 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 806
, N = none/not available) Command Name User Admin Operator Switch Admin Zone Admin Fabric Admin Basic Switch Admin Security Admin secPolicyDump O OM N O N OM O OM OM OM OM N OM O N statsTest O OM OM OM N OM O N 774 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 807
N = none/not available) Command Name User Admin Operator Switch Admin Zone Admin Fabric Admin Basic Switch Admin Security Admin stopPortTest O OM OM OM N OM O N N N N N N N OM trackChangesSet O OM OM OM O OM O OM Fabric OS Command Reference Manual 775 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 808
) Command Name User Admin Operator Switch Admin Zone Admin Fabric Admin Basic Switch Admin Security Admin trackChangesShow O OM N O N N OM OM OM N OM O O O OM O O O O O O O O O OM O O O O O O O O O O 776 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 809
, 348, 431, 464, 519, 623, 638, 641, 645, 677, 714 Brocade 24000 director, 42, 44, 57, 59, 77, 78, 83, 84, 86, 107, 233, 245, 348, 464, 519, 638, 641, 645, 648, 677, 714 Brocade 3014 switch, 59, 86, 233, 245 Brocade 3016 switch, 292 Brocade 3250 switch, 44, 57, 59, 84, 245, 464, 466, 519, 638, 641 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 810
135 and setMediaMode, 605 and systemVerification, 695 diagPost, 128 diagRetry burn-in script, 129 diagSetBurnin, 130 diagShowTime, 133 burn-in, 133 diagStatus, 135 diagStopBurnin, 136 DID used, 447, 448 DLS, see dynamic load sharing DMA test, 194 domain name service, 142 dual CP system active CP and - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 811
, 185 FDISC, 379, 383, 386, 499 FDMI, 221, 222 Fibre Channel Association, xxv Fibre Channel Extended Link Service, 185, 245, 506, 542 Fibre Channel Protocol, 191, 192 FICON, 111, 223, 224, 225, 226, 227, 230, 232, 471, 627, 628, 630, 631, 632, 633, 634, 661, 663, 664, 665, 677 FICON-MIB, 627, 630 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 812
379, 383, 386 ISL Inter-Switch Link, 425 ISL Trunking, 477, 633, 634 HBA, 221, 222, 228, 230 help, 284 help commands, 44, 84, 397, 398 history policy, 394 I idle timeout value, 296, 544, 698 ifModeSet active CP, 292 licenses, 77 Advanced Zoning, 32, 33, 34, 35, 63, 64, 65, 66, 67, Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 813
, 677 LSAN, see logical SAN lsanZoneShow zoning, 350 LSR, 708 P passwdCfg, 396 password and login, 346 and secHelp port type, 228, 229, 230, 232, 445, 489, 523, 542 128, 129, 130, 134, 171, 603, 621, 668, 672 disabling, 120 power-on self-test, see POST primary FCS, 24, 27, 30, 32, 33, 34, 35, 36, 64 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 814
64, 66, 70, 299, 506, 732, 733, 734, 740 QuickLoop Fabric Assist mode commands, 744 R R_A_TOV, 91, 95, 100, 101, 102, 457, 458, 478, 479 RADIUS, 3, 4 RASLOG, 655, 656, 657 RCS, 114, 362, 563, 657 read link status, 192 reboot, 55, 77, 78, 88, 102, 120, 121, 124, 126, 128 Reference Manual 53-1000436-01 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 815
673 switch speed, 669 switchBeacon, 666 switchShow, 677 SW-TRAP, 627, 630, 631, 632, 633, 634 syslog, 146, 689, 690, 692 sysShutdown active CP, 693 system services, 105 , 425, 673 Z zone, 729 zone alias, 33 adding, 32 T Tape Pipelining, 526 Fabric OS Command Reference Manual 53-1000436-01 Index 7 - HP StorageWorks 2/16V | Brocade Fabric OS Command Reference Manual - Supporting - Page 816
fcPing, 185 enabling zone configuration, 69 ISL R_RDY, 461 licensed commands, 743 zoning operation parameters, 104 zoning transaction aborting, 75 Index 8 Fabric OS Command Reference Manual 53-1000436-01
53-1000436-01