HP StorageWorks 2/16V HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY
HP StorageWorks 2/16V - SAN Switch Manual
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks 2/16V manual content summary:
- HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 1
Release Notes HP StorageWorks Fabric OS 3.1.3a Third Edition (September 2004) Part Number: AA-RUQYC-TE This document contains the latest version of these Release Notes and other Fabric OS 3.1.1x documentation, access the HP storage web site at: http://www.hp.com/country/us/eng/prodserv/storage.html. - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 2
to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 3
for installing, operating, and maintaining Fabric OS version 3.1.3. Overview HP Fabric OS 3.1.3a is a maintenance release containing fixes to bind PIDs ■ Improved fabric diagnostics Supports the pathInfo command, which displays path information between any two ports of a fabric ■ Improved - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 4
Documentation Supported Switches Fabric OS v3.1.3a supports the following switches: ■ HP StorageWorks SAN Switch 2/8 ■ HP StorageWorks MSA SAN switch 2/8 ■ HP StorageWorks SAN Switch 2/16 Technical Support Contact Hewlett-Packard support for hardware, firmware, and software support, including - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 5
Documentation 4. Locate the Fibre Channel Switches section. 5. Locate the B-Series Fabric subsection. 6. Click the name of the appropriate switch. The switch overview page displays. 7. Locate the Product information section. 8. Click Technical documentation. 9. Select the applicable documents. For - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 6
all aspects of standards. HP Fabric OS 3.1.3a conforms to the following Fibre Channel Standards: ■ FC-AL ANSI X3.272: 1996 ■ FC-AL-2 NCIT S 332: 1999 ■ FC-FLA NCIT S TR-20: 1998 ■ FC-GS-2 NCIT S 348-2000 Rev 7.01 ■ FC-FG ANSI X3.289: 1996 ■ FC-PH ANSI X3.230: 1994 ■ FC-PH-2 ANSI - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 7
release that does not support the Extended PID format), PID needs to be set back to a supported format, such as HP also recommends that you use the most recently released firmware to control the fabric. If you use Advanced Web Tools to change the switch name, the HP StorageWorks SAN Director 2/128 - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 8
HP recommends using Java 1.4.1_03. Two-Domain and Four-Domain Fabric Licensing If your fabric includes a switch with a license for a limited number of switches exceeds the supported switch configuration limit Gb/s switches. Installing Mozilla 1.4 on Solaris 8 and Solaris 9 For instructions to install - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 9
list of supported operating systems. Table 1: Browsers, Operating Systems, and Java Plug-ins Operating System HP-UX 11.00 Browser Mozilla 1.4 or later Java Plug-in 1.4.2_00 or later (up to but not including 1.5) HP-UX 11.11 (PA 32-bit & PA 64-bit) HP-UX 11.23 (IA 64-Bit) HP-UX 11.i HP Tru64 - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 10
later (up to but not 3.0 (IA32 & IA64) including 1.5) Red Flag Linux (32-bit) Mozilla 1.4 or later 1.4.2_02 or later (up to but not including 1.5) United Netscape Communicator 4.78 1.4.2 Windows 2000 IE 6.0 SP1 1.3.1_04 or 1.4.1_02 (recommended) Windows 2000 SP3 IE 6.0 SP1 1.4.1_03 - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 11
: Solaris Browser: Mozilla Firmware: version earlier than Fabric OS v2.6.2, v3.1.2, or v4.2.0 with secure mode enabled Operating System: Solaris Browser: Mozilla Issue and Workaround The Switch Admin does not launch correctly. Workaround: The Netscape browser is not supported by Web Tools. However - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 12
firmware. Workaround: Use a launch switch running Fabric OS v2.6.2, 3.1.2, or 4.2.0 or later to access the switch. When trying to perform end-to-end monitoring (Performance Monitor) on a SAN Director 2/128 or SAN Switch 2/8V, the SAN Director 2/128 or SAN Switch 2/8V will be displayed as a 16-port - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 13
Using Mixed OS Versions (Continued) Launch Switch Environment Firmware: version earlier than Fabric OS v2 Switch Explorer (not Fabric View). Fabric Watch Updates The Fabric Watch default thresholds have been revised so that fewer messages logged. Table 3: Fabric Watch Default Settings Class Port - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 14
Settings (Continued) Class Class Area name Description Default Settings Primitive sequence protocol error Monitors number of primitive sequence errors. Threshold Setting Unit Time Base Low High Buffer Error(s) Minute 1 60 0 Alarm Setting Changed 0 0 - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 15
Important Notes Table 3: Fabric Watch Default Settings (Continued) Class Class Area name Description Default Settings E_Port Link failure count Loss of synchronizat ion count Loss of signal count Primitive sequence protocol error Invalid transmission word Invalid CRC count Monitors - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 16
Settings (Continued) Class Class Area name Description Default Settings Fabric Copper Port Receive performance Transmit performance State changes Link failure count Loss Informative Normal Faulty Informative Informative Informative Normal Faulty Informative 16 Fabric OS 3.1.3a Release Notes - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 17
Settings (Continued) Class Class Area name Description Default Settings Loss of signal count Monitors number of signal loss errors Primitive sequence protocol error Monitors number of primitive sequence errors Invalid transmission word Monitors - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 18
Important Notes Table 3: Fabric Watch Default Settings (Continued) Class Class Area name Description Default Settings Fabric Optic Port Link failure count Monitors number of link failures Loss of synchronization count Monitors number of loss synchronization errors. Loss of signal count - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 19
Area name Description Default Settings Invalid messages in the HP StorageWorks Diagnostic and System Error Messages 3.1.x/4.1.x Reference Guide. If an event .x do not support FARP requests, only ARP requests. When using IP over Fibre Channel, confirm that all host HBAs support ARP requests and - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 20
the switch, the feature is not disabled until the switch is rebooted or a switch disable there are no spaces in the switch names of any switches in the fabric. The web site service) mode fabric (that is, in a fabric containing switches with firmware versions other than v2.6.x, v3.1, and v4.1), HP - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 21
describes the exact path that a user data stream takes to go from the source to the destination. If the user specifies the use of inactive ports or a path through a switch that does not have active routing tables to the destination, pathInfo will describe the path that would be used if the - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 22
, the routing information output includes the following: Hop The hop number, the local switch being hop 0. In Port Domain ID Name Out Port The port (or area) from which the frames come. For hop 0, the source port. For a switch with blades, this is specified as the area number; otherwise, as the - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 23
hops in the reverse path, if reverse-path tracing is requested. The default value for the maximum hop count is 25. Basic statistics Basic statistics In general, the path from port A on switch X to port B on switch Y might be different from the path from port B to port A. The difference could be - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 24
is sought. The embedded port (-1) is used by default. For a switch with blades, the destination is specified as the area; otherwise, as the port. If the source port is given as -1 with no additional arguments, then basic statistics will be displayed for the route. 24 Fabric OS 3.1.3a Release - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 25
stats trace reverse path A port on the destination switch. pathInfo will return the state of the port and all requested statistics pertaining to the port. The embedded port (-1) is used by default or if the specified destination port is not an existing active port. For a switch with blades, this is - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 26
user will not be prompted for the domain of the next switch; that is determined by the port (or area) specified. Default: no. Specifies that the source route must be followed strictly as indicated, skipping possible intermediate switches. When using this option, the source route must be specified - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 27
invoked with all operands on the command line: web226:root> pathInfo Max hops: (1..127) [25] Domain: (1..239) [-1] 8 Source port: (0..15) [-1] Destination port: (0..255) [-1] Basic stats (yes, y, no, n): [no] y Extended stats (yes, y, no, n): [no] y Trace reverse path (yes, y, no, n): [no] Source - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 28
and Changes Target port is Embedded Hop In Port Domain ID (Name) Out Port BW Cost 0 E 9 (web226) 2 1G 1000 Port E 2 Tx Rx Tx Rx B/s (1s) - - 0 0 B/s (64s) - - 1 1 Txcrdz (1s) - - 0 - Txcrdz (64s) - - 0 - F/s (1s - - 0 0 F/s (64s) - - 2743 0 Words - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 29
and Changes Hop In Port Domain ID (Name) Out Port BW Cost 2 14 8 (web229) E 1 - Port 14 E Tx Rx Tx Rx B/s (1s) 0 76 0 0 B/s (64s) 5 5 5 5 Txcrdz (1s) 0 - 0 - Txcrdz (64s) 0 - 0 - F/s (1s 0 1 0 0 F/s (64s) 0 0 0 0 Words 20158695 1021842 - - Frames - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 30
all users (display) admin (set/clear) Description This command affects the output displayed on the switch's console (serial port or telnet session). By default, quiet mode is turned off, and all switch tasks can send output to the console. Some output is caused by asynchronous events, such as - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 31
command now supports the -portcount option, which returns the number of ports on the switch. The syntax is: Synopsis switchShow, "-portcount configure The Domain, R_A_TOV, and E_D_TOV fields have changed, as follows: Fields Domain R_A_TOV E_D_TOV Default 1 10000 2000 Range varies E_D_TOV - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 32
portCfgGport On the SAN Switch 2/8-EL, a fabric license is required for the portcfggport command to function properly; otherwise, a "fabric support required" message displays commands cannot both be enabled at the same time; otherwise, fabric segmentation occurs. 32 Fabric OS 3.1.3a Release Notes - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 33
CLI Command Updates and Changes zonecreate The zonename operand has changed, as follows: zonename Name for a zone to be created, in quotation marks. This name cannot be used for any other zone objects. Zone names are limited to 64 characters. Fabric OS 3.1.3a Release Notes 33 - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 34
failed. This usually indicates an ASIC failure. This message is generated by the filtertest command, if problems are found. Recommended Action Replace the motherboard FRU for the SAN Switch 2/16. Replace the entire switch or the SAN Switch 2/8. Severity Critical 34 Fabric OS 3.1.3a Release Notes - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 35
or the cmitest command, if problems are found. Recommended Action Replace the motherboard FRU for the SAN Switch 2/16. Replace the entire switch or the SAN Switch 2/8. Severity Critical DIAG-CAMINIT Message Critical DIAG-CAMINIT, 1 Probable Cause Port failed to initialize due to one - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 36
cable or deteriorated SFP. Replace the cable or SFP if necessary. If the problem persists: For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-CAMSID Message Critical DIAG-CAMSID, 1 Probable Cause ASIC failed SID - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 37
by the statisticstest command, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-CLEAR_ERR Message Warning DIAG-CLEAR_ERR, 3 Probable Cause The port diag error flag (OK or - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 38
failure. This message is generated by the centralmemorytest command, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-CMBISRTO Message Critical DIAG-CMBISRTO, 1 The ASIC - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 39
the centralmemorytest command, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-CMERRTYPE Message Critical DIAG-CMERRTYPE, 1 Probable Cause A port received the wrong CMEM - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 40
failure. This message is generated by the cmitest command, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-CMIDATA Message Critical DIAG-CMIDATA, 1 Probable Cause - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 41
failure. This message is generated by the cmitest command, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-CMINOCAP Message Critical DIAG-CMINOCAP, 1 Probable Cause - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 42
by the cmitest command, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-CMNOBU Message Critical DIAG-CMNOBUF, 1 Probable Cause Port could not get any buffers. This - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 43
the cable or SFP. If the problem persists: For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-ERRSTAT (2LONG) Message Critical DIAG-ERRSTAT (2LONG), 1 Probable Cause The Port Error Statistics counter is nonzero - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 44
SFP if necessary. If the problem persists: For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-ERRSTAT (BADEOF) Message Critical DIAG-ERRSTAT (BADEOF), 1 Probable Cause The Port Error Statistics counter is nonzero - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 45
or SFP if necessary. If the problem persists: For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-ERRSTAT (CRC) Message Critical DIAG-ERRSTAT (CRC), 1 Probable Cause The Port Error Statistics counter is nonzero - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 46
SFP if necessary. If the problem persists: For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-ERRSTAT(CRL) Message Critical DIAG-ERRSTAT(CRL), 1 Probable Cause The Port Error Statistics counter is nonzero, meaning - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 47
or SFP if necessary. If the problem persists: For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-ERRSTAT (ENCIN) Message Critical DIAG-ERRSTAT (ENCIN), 1 Probable Cause The Port Error Statistics counter is nonzero - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 48
SFP if necessary. If the problem persists: For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-ERRSTAT (ENCOUT) Message Critical DIAG-ERRSTAT (ENCOUT), 1 Probable Cause The Port Error Statistics counter is nonzero - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 49
the cable or SFP if necessary. If the problem persists: For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-INIT Message Critical DIAG-INIT, 1 Probable Cause Port failed to go active in the loopback mode requested - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 50
cable or deteriorated SFP. Replace the cable or SFP if necessary. If the problem persists: For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-INTNIL Message Critical DIAG-INTNIL, 1 Probable Cause ASIC failed to - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 51
failure. This message is generated by the centralmemorytest command, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-LCMEM Message Critical DIAG-LCMEM, 1 Probable Cause - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 52
failure. This message is generated by the centralmemorytest command, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-LCMRS Message Critical DIAG-LCMRS, 1 Probable Cause - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 53
generated by the centralmemorytest and the cmemretentiontest commands, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-MEMNULL Message Critical DIAG-MEMNULL, 1 Probable - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 54
RAM failure. This message is generated by the ramtest command, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-MEMSZ Message Critical DIAG-MEMSZ, 1 Probable Cause Memory - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 55
Probable Cause Port is not present. This can be caused by a faulty cable or deteriorated SFP. It can also indicate deeper problems in the If the problem persists: For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Fabric OS - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 56
Port was in loopback mode and then went inactive. This can be caused by a faulty cable or deteriorated SFP. It can also indicate deeper problems If the problem persists: For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 57
the spinsilk command, if problems are found. Recommended Action Reconnect port (M) to a different port (N) and reexecute the test . If the problem persists: For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical Fabric - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 58
erroneously received by port M instead of the intended port N. This usually indicates an ASIC failure. This message is generated by the portloopbacktest command, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 59
the sramretentiontest commands, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-REGERR_UNRST Message Critical DIAG-REGERR_UNRST, 1 Probable Cause Port failed to unreset - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 60
cable or SFP if necessary. If the problem persists: For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-STATS (FRX) Message Critical DIAG-STATS (FRX), 1 Probable Cause Port counter value did not match the number of - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 61
cable or SFP if necessary. If the problem persists: For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-STATS (FTX) Message Critical DIAG-STATS (FTX), 1 Probable Cause Port counter value did not match the number of - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 62
This message is generated by the turboramtest command, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-TBRAM_INC_WTEST Message Critical DIAG-TBRAM_INC_WTEST, 1 Probable - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 63
the cable or SFP if necessary. If the problem persists: For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-XMIT Message Critical DIAG-XMIT, 1 Probable Cause Port failed to transmit frame. This usually indicates an - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 64
Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical FABRIC-RECONFIG Message Switch: , Info FABRIC-RECONFIG, 4, fabric: Probable Cause The fabric has reconfigured due to an offline port. The reason - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 65
the Pprincipal WWN and P\principal P\priority number as the principal switch. Recommended Action If the reconfiguration was unplanned, check for problems with the specified port. Some troubleshooting tasks include: Verify that the port was not disabled, using the portshow command. Verify that the - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 66
database exceeds the maximum size. This message can also be caused when the switch is short of memory. The value can be defined or active, Severity Error SEC-PIDCHGERR, PID Change failed: Size check failed Message Switch: , Error SEC-PIDCHGERR, 2, PID Change failed: Size check - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 67
. If the problem persists, reboot or power cycle the switch. Severity Error SEC-PIDCHGINFO Message Switch: , switch was changed either to or from extended-edge PID. If DCC policies exist, all area ID values either increase or decrease by 16. The values wrap around after a port value of 128 - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 68
: Secure fabric version stamp has been reset. ■ secFCSFailover: The primary FCS has failed over to a new switch. ■ All password changes: A, B, C account passwords have been changed. (A, B, C are account names for which passwords are changed.) ■ configDownload: A configdownload process has - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 69
, 3, Switch PID format changed to Format 2 ('Extended Edge PID Format'). Probable Cause The PID format for the fabric has been changed to Format 2, extended-edge PID. For more information on PID format, refer to the HP StorageWorks Fabric OS Version 3.1.x/4.1.x Procedures User Guide. Recommended - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 70
additions or corrections to documentation. HP StorageWorks SAN Switch 2/16 Installation Guide (Part Number: AA-RR84D-TE) On page 82, Table 9: The Temperature condition refers to the ambient air temperature at the air intake vents on the non-port side of the switch. You should change the Temperature - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 71
in general, refer to the HP StorageWorks Extended Fabrics Version 3.1.x/4.1.x User Guide. To: "...Trunking is supported for normal E_Ports (referred port configured does not require this mode. When configuring the second port of a connection, use this mode to initiate communication between the ports - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 72
Version 3.1.x/4.1.x User Guide (Part Number: AA-RS25C-TE) On page 122, the following row should be added to Table 24, "Configure (Fabric Field) Descriptions": Switch PID Format Allows you to select a switch PID format from one of the following: ■ VC encoding ■ Format 0 (16-port encoding) - Native - HP StorageWorks 2/16V | HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 73
Also, remove the following row from Table 24: VC Encoded Address Mode Set this mode only if the fabric includes a StorageWorks SAN switch. When set, the frame source and destination address use an address format that is compatible with StorageWorks SAN switches. Fabric OS 3.1.3a Release Notes 73
Release Notes
HP
StorageWorks
Fabric OS 3.1.3a
Third Edition (September 2004)
Part Number:
AA–RUQYC–TE
This document contains information about Fabric OS version 3.1.3a. In the event of conflicting
information between these Release Notes and other documents in this product release, the
Release Notes take precedence.
For the latest version of these Release Notes and other Fabric OS 3.1.1x documentation, access
the HP storage web site at:
.