HP StorageWorks 2/16V HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal
HP StorageWorks 2/16V - SAN Switch Manual
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks 2/16V manual content summary:
- HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 1
Installation Guide HP StorageWorks SAN Switch 2/8V 2/16V and 2/16N Product Version: 4.2.x Second Edition (April 2004) Part Number: AA-RVULB-TE This user guide provides procedures for setting up, configuring, and managing the SAN Switch 2/8V, SAN Switch 2/16V, and 2/16N models. - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 2
are set forth in the express limited warranty statements for such products. Nothing herein should be construed as constituting an additional warranty. Printed in the U.S.A. SAN Switch 2/8V, 2/16V and 2/16N Installation Guide Second Edition (April 2004) Part Number: AA-RVULB-TE - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 3
SAN Switch 2/8V, 2/16V and 2/16N Features 18 SAN Switch 2/8V and 2/16 Switches Comparison 18 SAN Switch Licensing 19 Switch Characteristics 20 Port Side 20 Nonport Side of SAN Switch 2/8V, 2/16V and 2/16N 21 ISL Trunking Groups 22 Supported (Optional) Features 23 Optional Hardware Kits 24 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 4
Off 58 Interpreting LED Activity 59 LED Location 60 LED Patterns 62 System and Power LED Patterns 62 Port LED Patterns 63 Ethernet LED Patterns 64 POST and Boot Specifications 65 POST 65 Boot 65 Interpreting POST Results 66 4 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 5
Serial Port Specifications 90 Power Supply Specifications 91 Weight and Physical Dimensions 92 Memory Specifications 93 Supported SFPs 94 Facility Requirements 95 Environmental Requirements 96 Supported HBAs 97 System Specifications 98 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 5 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 6
Contents Glossary 101 Index 113 Figures 1 Port Side of SAN Switch 2/8V 18 2 Port Side of the SAN Switch 2/16V and 2/16N 19 3 Trunking groups 20 4 Shipping carton contents 25 5 Installing the rear mounting brackets (HP 10000 series or comparable EIA cabinet). . . 35 6 Installing the rear - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 7
Options 66 14 Laser Data Transmission Ranges 86 15 Power Supply Specifications 89 16 Switch specifications 90 17 Memory Specifications 91 18 Facility Requirements 93 19 Environmental Requirements 94 20 General Specifications 96 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 7 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 8
Contents 8 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 9
guAidbe porouvitdetshinisforGmautioindtoehelp you configure the HP StorageWorks SAN Switch 2/8V, SAN Switch 2/16V, and SAN Switch 2/16N. About this Guide Note: Throughout this guide, information about the SAN Switch 2/16V is applicable to the SAN Switch 2/16N, unless otherwise noted. "About this - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 10
Switch 2/16N. The switch overview page displays. 7. Go to the product information section, located on the far right side of the web page. 8. Click technical documents. 9. Follow the onscreen instructions to download the applicable documents. 10 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 11
About this Guide Conventions Conventions consist of the following: ■ Document Conventions ■ Text Symbols ■ Equipment Symbols font unless they are case sensitive Blue, underlined sans serif font text: http://www.hp.com SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 11 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 12
symbols indicates the presence of electrical shock hazards. Enclosed area contains no operator serviceable parts. WARNING: To reduce the risk of personal injury from electrical shock or telecommunications connectors into this receptacle. 12 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 13
About this Guide Any surface or area of the equipment marked with these symbols indicates the presence of a or damage to the equipment, observe local occupational health and safety requirements and guidelines for manually handling material. SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 13 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 14
Guide Rack Stability Rack stability protects personnel and equipment. WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that: ■ The leveling jacks are extended to the floor. ■ The full extended for any reason. 14 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 15
. HP Authorized Reseller For the name of your nearest HP authorized reseller: ■ In the United States, call 1-800-345-1518. ■ In Canada, call 1-800-263-5868. ■ Elsewhere, see the HP web site for locations and telephone numbers: http://www.hp.com. SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 16
About this Guide 16 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 17
2/16N includes a full-fabric license. Note: Unless otherwise noted, functionality and features for the 2/16V are applicable to the 2/16N throughout this guide. This chapter provides the following information: ■ SAN Switch 2/8V, 2/16V and 2/16N Features, page 18 ■ Switch Characteristics, page 20 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 18
fabric enabled), FL_Port (fabric loop enabled), or E_Port (expansion port). ■ 8 or 16 short wavelength SFP transceivers (optional). ■ One RS-232 serial port, designed to connect to a DTE port. ■ One 10/100 Mb/sec Ethernet port with an RJ-45 connector. ■ One (SAN Switch 2/8V) or two (SAN Switch 2/16V - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 19
4-domain fabric license or a full-fabric license. ■ The SAN Switch 2/16N comes configured from the factory with a full-fabric license. The SAN Switch 2/8V and 2/16V products can be upgraded by purchasing an optional license; refer to the HP StorageWorks Fabric OS Procedures 4.2x User Guide to learn - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 20
6 7 0018a Figure 1: Port Side of SAN Switch 2/8V Table 2 lists the SAN Switch 2/8V port side components. Table 2: SAN Switch 2/8V port side components Number 1 2 3 4 Description AC power receptacle Ethernet port Serial port FC ports (8) 20 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 21
components Number 1 2 3 4 5 Description AC power receptacle Ethernet port Serial port FC Ports (16) Second AC power receptacle Nonport Side of SAN Switch 2/8V, 2/16V and 2/16N The nonport side of the SAN Switch 2/8V, 2/16V and 2/16N is used solely for air flow and for serial number labels. There - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 22
14 15 Figure 3: Trunking groups Note: ISL Trunking is optional software that allows you to create trunking groups of ISLs between adjacent switches. For more information about trunking, refer to the HP StorageWorks Features 4.2x User Guide. 22 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 23
a SAN Switch 2/16N power pack, it also includes the following optional software. ■ ISL Trunking ■ Fabric Watch ■ Advanced Performance Monitoring ■ Extended Fabrics ■ Remote Switch For information on any of these features, refer to the HP StorageWorks Features 4.2x User Guide. SAN Switch 2/8V, 2/16V - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 24
Table 4 lists optional hardware kits that support of the SAN Switch 2/8V, 2/16V and 2/16N. Table 4: Orderable Hardware Accessory Short wavelength -B26** 221691-B27** C7534A* C7534A* * premerger HP part number ** premerger Compaq part number 24 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 25
Stand-Alone SAN Switch 2/8V, 2/16V and 2/16N, page 31 ■ Installing a SAN Switch 2/8V, 2/16V or 2/16N Into an EIA Cabinet, page 32 ■ Cabling and Configuring the SAN Switch 2/8V, 2/16V or 2/16N, page 47 ■ Items Required for Installation, page 48 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 25 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 26
this RS-232 cable to an RJ-45 connector by removing the adapter on the end of the cable. - One HP StorageWorks SAN Switch Rack Mount Kit, with instructions. - The HP StorageWorks SAN Switch 2/8V and 2/16V Installation Guide (this document). 26 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 27
Figure 4 shows the shipping carton contents. 3 Installing the SAN Switch 4 5 1 2 6 0011a Figure 4: Shipping carton contents Note: Throughout the rest of this guide, examples in figures show the SAN Switch 2/16V, unless otherwise noted. SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 27 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 28
Guide, Safety Guides, User License and Warranty One HP StorageWorks SAN Switch 2/8V, SAN Switch 2/16V, or SAN Switch 2/16N. One standard AC power cord, and one PDU cord for the SAN Switch 2/8V. The SAN Switch 2/16V includes two AC power cords and two PDU cords (not shown). One RS-232 Serial - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 29
cool-air aisle. ■ Verify that a minimum of 24 cubic ft./minute of air flow is available to the air intake vents on the nonport side of the switch. ■ Verify that the ambient air temperature does not to a branch circuit, such as a power strip. SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 29 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 30
assembly. - Verify that the additional weight of the switch does not exceed the cabinet's weight limits or unbalance the cabinet in any way. - Secure the cabinet to ensure stability in case of unexpected movement, such as an earthquake. 30 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 31
Switch On and Off" on page 58. Caution: Do not connect the switch to the network until the IP address is correctly set. For instructions on how to set the IP address, see "Cabling and Configuring the SAN Switch 2/8V, 2/16V or 2/16N" on page 47. SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 32
The air is expelled through vents in the front (port side) of the chassis, next to the HP logo. HP recommends installing the switch so that air intake and exhaust for all components in the rack are flowing in the same front-to-back direction. 32 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 33
electrical codes ■ Adequate supply circuit, line fusing, and wire size, as specified by the electrical rating on the switch nameplate ■ Voltage capability of 85-264 VAC ■ Input voltage frequency of 47-63 Hz ■ Power capability of 75 W minimum SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 33 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 34
one technician. The following items are required to install the switch in a cabinet: ■ SAN Switch 2/8V, SAN Switch 2/16V or SAN Switch 2/16N ■ Power cables ■ #2 Phillips screwdriver ■ 7/16-inch wrench or socket The SAN Switch Rack Mount Kit rails and rail mounting hardware listed in Table - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 35
screw for use with the SAN Switch 2/8, SAN Switch 2/8V, SAN Switch 2/16, SAN Switch 2/16V and SAN Switch 2/16N (screw not shown here). (10) #10-32 x 1/2-inch Phillips pan-head screw with captive star lock washer (8) #10 alignment washer (8) #10 adapter washer (2) 1/4-20 hex nut with captive star - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 36
2/16V must face the rear of the rack. This mounting allows air to enter from the front of the rack and to exhaust at the rear of the rack, similar to other rack-mounted equipment. This prevents switch overheating, which may cause it to fail. 36 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 37
mounting brackets (HP 10000 series or comparable EIA cabinet) - For an HP System/e rack, install each of the two rear mounting brackets with (2) #10-32 x 1/2-inch Phillips pan-head screws and (2) #10 alignment washers as shown in Figure 6. SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 37 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 38
6: Installing the rear mounting brackets (HP System/e rack-left rear upright) Note: This kit contains both left rails and right rails. The rails are marked with Right and Left. 4. Assemble the outer rails by completing the following steps: 38 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 39
1/4-20 hex nuts with captive star lock washers attached loosely as shown in Figure 7. Don't tighten them. The nuts will be tightened later in step 8 on page 46. Figure 7: Installing the outer rails (HP 10000 series or comparable EIA cabinet) SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 39 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 40
lock washers and two #10 adapter washers in the upper and lower hole locations of the left rail. See Figure 8. Figure 8: Assembling the outer rails (HP 10000 series or comparable EIA cabinet) 40 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 41
two #10-32 x 1/2-inch Phillips pan-head screws with captive star lock washers and two #10 alignment washers in the upper and lower hole locations of the left rail. See Figure 9. Figure 9: Assembling the outer rails (HP System/e cabinet) SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 41 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 42
Table 7: Number of screws required to assemble the inner rails Switch SAN Switch 2/16V, SAN Switch 2/16N SAN Switch 2/8V Number of #8-32 x 5/16-inch Screws 10 10 6. For the SAN Switch 2/16V, complete step a on page 43. For the SAN Switch 2/8V, complete step b on page 44. Caution: Do not use any - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 43
five screws. Attaching both inner rails requires ten screws. 0012a Figure 10: Assembling the inner rails Note: For factory integration only, tighten the #8-32 x 5/16-inch Phillips pan-head SEMS screws and torque between 6 to 8 inch-pounds. SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 43 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 44
b on page 44 for instructions. 1 2 0013a Figure 11: Assembling the inner rails on a SAN Switch with plenum The components in Figure 11 include: 1 Plenum 2 Switch 7. Insert the switch with the attached inner rails into the outer rails. 44 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 45
the switch into a rack (HP 10000 series or comparable EIA cabinet) Insert the switch into the rack and install (2) #10-32 x 1/2-inch Phillips pan-head screws with captive star lock washers with one on each side. See Figure 12 and Figure 13. SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 45 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 46
nuts installed in step a on page 39 of step 4 on page 39. See Figure 7 on page 39. Note: To uninstall a switch, remove the middle #10-32 x 1/2-inch Phillips pan head screw with captive star lock washer from either side of the rack uprights. 46 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 47
2/8V, 2/16V or 2/16N The SAN Switch 2/8V or 2/16V must be configured to ensure correct operation within a network and fabric. For instructions about configuring the switch to operate in a fabric containing switches from other vendors, refer to the HP StorageWorks Fabric OS Procedures 4.2x User Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 48
Switch and Log In, page 50 3. Set the IP Address, page 51 4. Create an Ethernet Connection and Log In, page 52 5. Modify the Fibre Channel Domain ID (Optional), page 53 6. Install the SFP Transceivers, page 54 7. Connect the Cables, page 54 48 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 49
45 connector instead of an RS-232, remove the adapter on the end of the serial cable and insert the exposed RJ-45 connector into the RJ-45 serial port on the workstation. 3. Disable any serial communication programs running on the workstation. SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 49 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 50
the SAN Switch 4. Open a terminal emulator application (such as HyperTerminal on a PC or TERM in a UNIX environment) and configure the application as follows: ■ In a Windows 95, 98, 2000, or the power cords 100-240 VAC 1.0A 47-63Hz 0015a 50 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 51
; the logon is "admin" and the default password is "password". Up to two simultaneous admin sessions and four user sessions can be created. For details, refer to the HP StorageWorks Fabric OS Procedures 4.2x User Guide and the Fabric OS 4.2.x Command Reference Guide. Set the IP Address Replace the - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 52
, the switch can be accessed remotely, by command line or by Advanced Web Tools. Ensure that the switch is not being modified from any other connections during the remaining steps. 2. Log in to the switch by telnet, using the admin account. 52 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 53
command at the prompt. This command sets the policy parameters that determine the overall switch status. b. Customize the status policies as desired. To deactivate the alarm for a particular condition, enter 0 at the prompt for that condition. SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 53 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 54
latching mechanism clicks. If a cable does not install easily, ensure it is correctly oriented. For instructions specific to cable type, refer to the cable manufacturer's documentation. 2. Repeat for the remaining transceivers, as required. 54 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 55
recent configuration is available for downloading to a replacement switch, if required. For specific instructions about how to back up the configuration, refer to the HP StorageWorks Fabric OS Procedures 4.2x User Guide. Back up the switch configuration to an FTP server by entering the configupload - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 56
Installing the SAN Switch 56 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 57
provides the following information: ■ Powering the Switch On and Off, page 58 ■ Interpreting LED Activity, page 59 ■ LED Location, page 60 ■ LED Patterns, page 62 ■ POST and Boot Specifications, page 65 ■ Interpreting POST Results, page 66 3 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 57 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 58
to the SAN Switch 2/8V or SAN Switch 2/16V, remove the power cord from the power source. Note: Removing all power from the switch triggers a system reset. All devices are returned to their initial state the next time the switch is powered on. 58 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 59
not indicate a problem unless the LEDs do not indicate a healthy state after all boot processes and diagnostic tests are complete. A healthy state is indicated by a steady green light. See Table 10 on page 62 for details about LED activity. SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 59 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 60
2/8V LED Locations Component 1 Description Ethernet LEDs 2 System and Power LEDs 3 Port LEDs The 2/8V and 2/16V switches are physically similar except for the number of ports-and related port LEDs-and the second AC power receptacle. 60 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 61
15 1 2 3 Figure 18: SAN Switch 2/16V LED locations Table 9 lists the LEDs locations. Table 9: SAN Switch 2/16V LED Locations Component 1 Description Ethernet LEDs 2 System and Power LEDs 3 Port LEDs 100-240 VAC 2.0A 47-63Hz 00 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 61 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 62
loopback plugs. Correct error condition. Clear error log. Amber One failed power supply in the SAN Switch 2/16V Rerun diagnostics to verify fix. No action required, but failure of the remaining power supply will cause the switch to fail. 62 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 63
disabled. No action required. No action required. Enable the port: use the portEnable command; refer to HP StorageWorks Fabric OS Reference for more information. If all ports are slow-flashing amber, enable the switch (switchEnable command). SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 63 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 64
Managing the SAN Switches Table 11: Port LED Patterns During Normal Operation (Continued) LED Name, Location LED Color Fast-flashing amber ( Action No action required. No action required. Below port on Blinking right green traffic 64 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 65
, and if any ports are connected to other switches, the switch participates in a fabric configuration. 4. Switch obtains a domain ID and assigns port addresses. 5. Unicast routing tables are constructed. 6. Normal port operation is enabled. SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 65 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 66
commands, and on accessing the error log, refer to the HP StorageWorks Fabric OS Procedures 4.2x User Guide. For information about error messages, refer to the HP StorageWorks Diagnostic and System Error Messages 4.2.x Reference Manual. 66 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 67
fabric as well as maintain the switch health. This chapter provides the following information: ■ SAN Switch 2/8V, 2/16V and 2/16N Management Features, page 68 ■ Maintaining the SAN Switch 2/8V, SAN Switch 2/16V and SAN Switch 2/16N, page 70 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 67 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 68
list of HBAs supported by the SAN Switch 2/8V, 2/16V and 2/16N, contact your HP representative. Table 13: Management Options Management Tool Command line interface Up to two admin sessions and four user sessions simultaneously. For more information, refer to the HP StorageWorks Fabric OS Procedures - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 69
.168.1.10 192.168.65.10 any not self Second Switch 204.1.1.11 192.168.65.11 192.168.1.10 Third Switch 204.1.1.12 192.168.65.12 192.168.1.10 The disadvantage of this method is the management station can not address anything but the switches. SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 69 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 70
beneath the port. Non-baled SFPs can be damaged by the removal process and are not recommended. See "Optional Hardware Kits" on page 24 for a list of supported SFPs and devices. 5. Repeat this procedure for the remaining ports as required. 70 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 71
and Upgrade Firmware Figure 19 shows the SFP installation and removal steps. Cable Release SAN Switch 1 100-240 VAC 1.0A 47-63Hz FC Ports IOIOI ! Bale SFP 3 scale: 1/8" = 1" SFP 2 4 Figure 19: Installing or removing an SFP 4.004 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 71 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 72
Refer to the HP StorageWorks SAN Design Reference Guide for a list of supported SFPs and devices. 5. Repeat this procedure for the remaining ports as required. Diagnostic Tests In addition to POST, Fabric OS includes diagnostic tests to help troubleshoot the hardware and the firmware. This includes - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 73
Noise Declaration, page 78 ■ VCCI EMC Statement (Japan), page 79 ■ RRL EMC Statement (Korea), page 80 ■ Laser Safety, page 81 ■ Battery Replacement Notice, page 83 A SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 73 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 74
radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in the equipment. The Regulatory Series Number is HSTNM-N001 74 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 75
Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la Classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 75 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 76
Regulatory Compliance Notices EMC Statement (European Union) This is a Class A product. In a domestic environment this product may cause radio interference, in which case the user may be required to take adequate measures. 76 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 77
CISPR 22)-Electromagnetic Interference ■ EN55024 (IEC61000-4-2, 3, 4, 5, 6, 8, 11)-Electromagnetic Immunity ■ EN61000-3-2 (IEC61000-3-2)-Power Line Harmonics ■ EN61000-3-3 (IEC61000-3-3)-Power Line Flicker ■ EN 60950 (IEC 60950)-Product Safety SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 77 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 78
Regulatory Compliance Notices Germany Noise Declaration Schalldruckpegel Lp = 46.1 dB(A)Am Arbeitsplatz (operator position) Normaler Betrieb (normal operation) Nach ISO 7779:1999 (Typprüfung) 78 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 79
VCCI EMC Statement (Japan) Regulatory Compliance Notices SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 79 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 80
Regulatory Compliance Notices RRL EMC Statement (Korea) 80 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 81
Class 1 Laser product, conforming to the requirements contained in Department Of Health and Human Services (DHHS) regulation 21 CFR, Subchapter J. The certification is indicated by a label on the 1 Laser products are not considered hazardous. SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 81 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 82
installation guide may serviceable components inside. Do not operate controls, make adjustments, or perform procedures to the laser device other than those specified herein. Allow only HP Authorized Service technicians to repair the unit. 82 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 83
replacement or proper disposal, contact your HP authorized reseller or your authorized service provider. WARNING: Your switch contains an internal lithium manganese dioxide or return them to HP, your authorized HP partners, or their agents. SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 83 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 84
Regulatory Compliance Notices 84 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 85
removing them from their containers. ■ Avoid touching pins, leads, or circuitry. ■ Always make sure you are properly grounded when touching a static-sensitive component or assembly. SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 85 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 86
conductive field service tools. ■ Use a portable field service kit with HP authorized reseller install the part. Note: For more information on static electricity, or for assistance with product installation, contact your HP authorized reseller. 86 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 87
Supply Specifications, page 91 ■ Weight and Physical Dimensions, page 92 ■ Memory Specifications, page 93 ■ Facility Requirements, page 95 ■ Environmental Requirements, page 96 ■ Supported HBAs, page 97 ■ System Specifications, page 98 C SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 87 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 88
300 m.) n/a 984 ft.(300 m.) 492 ft.(150 m.) n/a Long Wavelength n/a n/a 6.2 miles (10 km) Optional Long Wave SFPs are required. n/a n/a 6.2 miles (10 km) without an HP Extended Fabrics license; 50 to 100 km with a HP Extended Fabrics license. 88 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 89
Fibre Channel Port Specifications The Fibre Channel ports in the SAN Switch 2/8V, SAN Switch 2/16V and SAN Switch 2/16N are compatible with SWL and LWL SFP transceivers. The strength the highest speed of which all attached devices are capable. SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 89 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 90
the fabric. The serial port's parameters are 9600 baud, 8 data bits, no parity, 1 stop bit, and no flow control. The port requires a straight (extension) serial cable with a female 9-pin subminiature-D connector. Only pins 2, 3, and 5 are supported. 90 SAN Switch 2/8V, 2/16V and 2/16N Installation - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 91
power factor correction per IEC1000-3-2 BTU rating SAN Switch 2/8V: 120 BTU SAN Switch 2/16V: 266 BTU Inrush current SAN Switch 2/8V: 20A SAN Switch 2/16V: 25A, each line input Input line protection Fused in both hot and neutral lines SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 91 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 92
42.85 cm) 12.10 in (30.734 cm) 8.2 lb (3.72 kg) with no media installed SAN Switch 2/16V and SAN Switch 2/16N 1.69 in (4.29 cm) 16.87 in (42.85 cm) 12.10 in (30.734 cm) 9.4 lb (4.27 kg) with no media installed Fixed-Rail Kit 2.6 lb (1.18 kg) 92 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 93
Technical Specifications Memory Specifications Memory specifications are shown in Table 17: Table 17: Memory Specifications Memory Type Main Memory (SDRAM) Kernel Flash Boot Flash Compact Flash 128 MB 16 MB 512 KB 256 MB Install Memory SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 93 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 94
24 for a list of supported SFPs. Do not use non-supported SFPs, as these can affect switch operability. They might not fit correctly and could void your warranty. For a complete list of supported devices, contact your local HP Representative. 94 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 95
in cabinet grounded through a reliable branch circuit connection Additional weight of switch must not exceed the cabinet's weight limits Cabinet must be secured to insure stability in case of unexpected movement, such as an earthquake SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 95 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 96
sea level Shock Vibration Air flow 20 G, 6 ms duration, half sine wave 0.5 G, 5-500 Hz Normal: 24 cubic ft/minute 15 G, 12- Fabric Watch alerts will indicate a problem. Enter the tempshow or Fabric Watch commands to view temperature status. 96 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 97
Technical Specifications Supported HBAs For a list of HBAs that have been tested and are known to work with the SAN Switch 2/8V, SAN Switch 2/16V and SAN Switch 2/16N, contact your local HP Representative. SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 97 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 98
the system specifications for the SAN Switch 2/8V, SAN Switch 2/16V and SAN Switch 2/16N. Table 20: General Specifications Specification Configurable port types System architecture System processor ANSI Fibre Channel protocol Modes of operation Fabric initialization FC-IP (IP over Fibre Channel - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 99
20: General Specifications (Continued) Aggregate switch I/O bandwidth Port-to-port latency EMC (electromagnetic compatibility) 64 Gb/sec if all 16 ports running at 2 Gb/sec, full duplex Less than 2 microseconds with no contention (destination port is free) Emissions An operating SAN Switch 2/8V - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 100
Technical Specifications 100 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 101
fabric software facility that supports multicast group management. API Application programming interface. A defined protocol that allows applications to interface with a set of services to all devices in the fabric, regardless of zoning. SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 101 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 102
The set of all zone objects defined in the fabric. May include multiple zone configurations. DLS Dynamic load sharing. Dynamic distribution of traffic over available paths. Allows for recomputing of routes when an Fx_Port or E_Port changes status. SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 103
switches in a fabric, used in routing frames. Usually automatically assigned by the principal switch, but can be assigned manually. The domain ID for an HP switch can be any integer between 1 and 239. Generally, the default or both directions. SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 103 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 104
-Replaceable Unit. A component that can be replaced on site. FS Fibre Channel Service. A service that is defined by fibre channel standards and exists at a well-known address. For example, the Simple Name Server is a fibre channel service. 104 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 105
protocol for all fabric services, transparent to the fabric type or topology. FSPF Fabric shortest path first. HP's routing protocol for fibre channel switches. Fx_Port A fabric port that can or nonidentical parameters (such as E_D_TOVs). SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 105 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 106
be in one of two modes: Fabric mode: Connected to a port that is not loop capable, and using fabric protocol. Loop mode: In an consisting of both transmit and receive fibres. link services A protocol for link-related actions. LIP Loop initialization SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 107
loop. LWL Long wavelength. A type of fiber optic cabling that is based on 1300mm lasers and supports link speeds up to 2 Gbit/sec. May also refer to the type of transceiver. M channel port or to another N_Port in a point-to-point connection. SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 107 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 108
and retransmit received transmissions. path selection The selection of a transmission path through the fabric. HP switches use the FSPF protocol. phantom address An AL_PA value that is assigned to an between each pair of communicating entities. SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 109
not log into the fabric. public device A device that supports arbitrated loop protocol, can interpret 8-bit addresses, and can log into the fabric. public loop An arbitrated time a frame can be delayed in the fabric and still be delivered. SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 109 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 110
of related frames transmitted in the same direction between two N_Ports. service rate The rate at which an entity can service requests. single mode The fiber optic cabling standard that corresponds to distances of up to 10 km between devices. 110 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 111
A switch service that stores names Switched fabric: Multiple N_Ports linked to a switch by F_Ports. Arbitrated loop: Multiple NL_Ports connected in a loop. transmission character A 10-bit character encoded according to the rules of the 8b/10b algorithm. SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 112
a U_Port when it is not connected or has not yet assumed a specific function in the fabric. well-known address As pertaining to fibre channel, a logical address defined by the fibre channel enables all zones in that configuration. 112 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 113
audience 10 authorized reseller, HP 15 B backup 55 SAN switch, for operation 47 status policies 53 terminal emulator application 50 connecting cables 55 conventions document 11 equipment symbols 12 text symbols 12 creating serial connection 49 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 114
the switch as a stand-alone unit 31 installing the switch in a cabinet 32 installing SFP 54, 70 intake vents 29 inventory 26 IP address 31, 48, 51, 90 IP over FC 68 ipaddrset 51 ipaddrshow 51 ISL trunking 23 about 22 cabling requirements 47, 54, 55 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 115
50 protocol, ANSI 98 R rack mount hardware 28 mount kits 32 rack stability, warning 14 rails 34 real-time clock 26 reference books 68 regulatory compliance identification numbers 83 notices 73 related documentation 10 Remote Switch 23 Index SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 115 - HP StorageWorks 2/16V | HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 116
RJ-45 connector 18, 26 RS-232 connector 18, 26, 90 rubber feet 32 SNMP 68 specifications Fibre Channel ports 89 general 98 power supply 91 serial port 90 stand-alone installation 31 status Ethernet ports 64 switch 92 wire size 29 WWN 21 Z zoning 23 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide
Installation
Guide
HP
StorageWorks
SAN Switch 2/8V
2/16V and 2/16N
Product Version:
4.2.x
Second Edition (April 2004)
Part Number:
AA°RVULB°TE
This user guide provides procedures for setting up, configuring, and managing the SAN Switch
2/8V, SAN Switch 2/16V, and 2/16N models.