HP StorageWorks Fabric OS 5.x command reference guide Part number: AA-RVHVB-TE Second edition: September 2005 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 2
Company, L.P. © Copyright 2005, Brocade Communications Systems, Incorporated. Hewlett-Packard Company HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 3
Contents About this guide 13 Intended audience 13 Related documentation 13 HP StorageWorks Fabric OS 5.x master glossary 13 Document conventions and symbols 14 HP technical support 15 HP-authorized reseller 15 Helpful web sites 15 1 Fabric OS command line interface 17 Understanding access - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 4
cfgRemove 88 cfgSave 90 cfgShow 92 cfgSize 95 cfgTransAbort 97 cfgTransShow 98 chassisConfig 99 chassisName 103 chassisShow 104 chipRegShow 108 cmemRetentionTest 109 cmiTest 111 configDefault 113 configDownload 115 configShow 118 configUpload 120 configure 123 crossPortTest 132 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 5
faZoneRemove 207 faZoneShow 209 fcPing 210 fcpLogClear 213 fcpLogDisable 214 fcpLogEnable 215 fcpLogShow 216 fcpProbeShow 218 fcpRlsShow 220 fdmiCacheShow 221 fdmiShow 222 ficonClear 289 haSyncStart 291 haSyncStop 292 help 293 historyLastShow 294 Fabric OS 5.x command reference guide 5 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 6
historyMode 295 historyShow 296 httpCfgShow 299 i 300 ifModeSet 302 ifModeShow 304 interfaceShow 305 interopMode 309 iodReset 311 iodSet 312 iodShow 313 ipAddrSet 314 ipAddrShow 316 islShow 317 itemList 318 killTelnet 320 licenseAdd 322 licenseHelp 323 licenseIdShow 324 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 7
490 portLogShow 491 portLogShowPort 496 portLogTypeDisable 498 portLogTypeEnable 499 portLoopbackTest 500 portName 503 portPerfShow 505 portRegTest 506 portRouteShow 508 portShow 510 Fabric OS 5.x command reference guide 7 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 8
portStats64Show 514 portStatsClear 517 portStatsShow 518 portSwap 521 portSwapDisable 523 portSwapEnable 524 portSwapShow 525 portTest 526 portTestShow 528 powerOffListSet 530 powerOffListShow 533 psShow 535 qloopAdd 537 qloopCreate 538 qloopDelete 540 qloopRemove 541 qloopShow 543 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 9
712 traceDump 714 traceFtp 716 traceTrig 718 trackChangesHelp 720 trackChangesSet 721 trackChangesShow 723 trunkDebug 724 trunkShow 726 tsClockServer 727 tsTimeZone 729 Fabric OS 5.x command reference guide 9 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 10
the primary FCS 773 5 MUA-based roles 777 switchAdmin Role Permissions 777 6 Control processor commands 787 Commands supported on the active CP 787 Commands supported on the standby CP 787 7 supportShow reference 789 supportShow control commands 789 supportShow command groups 789 Proc entry - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 11
monitoring commands 770 26 HP secure fabric OS commands 771 27 Commands exclusive to the primary FCS 773 28 switchAdmin commands 777 29 Commands supported on the standby CP 787 30 supportShow command groups 789 31 proc entry information displayed 792 Fabric OS 5.x command reference guide 11 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 12
12 Contents - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 13
: FICON is not supported on HP B-Series Fibre Channel switches. The FICON information in this document is included for reference only. Intended audience This guide is intended for: • System administrators responsible for HP StorageWorks Fibre Channel Storage Area Network (SAN) switches • Technicians - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 14
Convention Medium blue text: Figure 1 Medium blue, underlined text (http://www.hp.com) Bold font Element Cross-reference links and e-mail addresses Web site IMPORTANT: Provides clarifying information or specific instructions. NOTE: Provides additional information. TIP: Provides helpful hints - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 15
sign up online using the Subscriber's choice web site: http://www.hp.com/go/e-updates. • Subscribing to this service provides you with e-mail updates on the latest product enhancements, newest versions of drivers, and firmware documentation updates as well as instant access to numerous other product - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 16
16 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 17
different methods used to manage HP SAN and HP StorageWorks switches. The following information is discussed: • Understanding access levels, page 17 • Using the Fabric OS command line interface, page 18 • Using this guide, page 19 Understanding access levels Fabric OS supports two classes of user - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 18
; however, the role is restricted to user-level, observation-based functions. This manual lists all the commands available to the user- and admin-level logins. See on an HP StorageWorks switch. The Fabric OS CLI enables an administrator to monitor and manage entire fabrics, individual switches, and - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 19
licenses Using this guide This guide describes each command, including a synopsis of its syntax and the users to which it is available, and provides a description of command usage and behavior. The same information is available to you on your HP StorageWorks SAN Switch or Director, using the help - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 20
20 Fabric OS command line interface - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 21
2 Fabric OS commands This chapter lists the Fabric OS commands. It also shows their syntax and operands, and provides examples of their usage. Fabric OS 5.x command reference guide 21 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 22
persistently. It is effective for the next AAA request. The configuration applies to all switch instances in a platform supporting multiple switch domains. Use the centralized RADIUS servers to manage AAA services for a switch, as defined in RFC 2865. NOTE: This command can be executed when you are - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 23
The following provides a detailed description of each action type: --show List the current RADIUS servers, along with their parameters. Fabric OS 5.x command reference guide 23 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 24
RADIUS server is used. --radius [on | off] Enable or disable the current RADIUS configuration for AAA services. This is used to switch the primary AAA services between RADIUS and the switch local database. To enable the RADIUS configuration, there must be at least one server existing in the - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 25
switch. This command resets the following values (See the HP StorageWorks Fabric OS 5.x MIB reference guide value for this parameter is 0 (disabled). There are six communities and respective trap recipients supported by the agent. The first three communities are for read-write (rw) access and the - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 26
is defined by comparing nonzero IP octets. For example, an ACL of 192.168.64.0 enables access by any hosts that start with the specified octets. The connecting host Community strings can be changed on the primary FCS switch only and will propagate changes across the fabric. Operands none Examples To - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 27
configured yet SNMP access list configuration: Entry 0: Access host subnet area 192.168.64.0 (rw)] Entry 1: No access host configured yet Entry 2: No access II system variables: sysDescr = Fibre Channel Switch. sysLocation = End User Premise sysContact = Field Support. authTraps = 0 (OFF) (continued - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 28
SNMPv1 community and trap recipient configuration: Community 1: Secret C0de (rw) No trap recipient configured yet Community 2: OrigEquipMfr (rw) No trap recipient configured yet Community 3: private (rw) No trap recipient configured yet Community 4: public (ro) No trap recipient configured yet - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 29
switch. This command updates the following values (See the HP StorageWorks Fabric OS 5.x MIB reference guide value for this parameter is 0 (disabled). There are six communities and respective trap recipients supported by the agent. The first three communities are for read-write (rw) access and the - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 30
is defined by comparing nonzero IP octets. For example, an ACL of 192.168.64.0 enables access by any hosts that start with the specified octets. The connecting host is strings can be changed on the primary FCS switch only and will propagate changes across the fabric. Operands none Examples To - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 31
FC Switch] sysLocation: [End User Premise] sysContact: [Field Support.] address in dot notation: [0.0.0.0] 192.168.64.88 Trap recipient Severity level : (0..5) [0] subnet area in dot notation: [0.0.0.0] 192.168.64.0 Read/Write? (true, t, false, f): , Switch Management Information & Switch Enterprise - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 32
Switch. The location of the system. The default value is End User Premise. The contact information for the system. The default value is Field Support. See the HP StorageWorks Fabric OS 5.x MIB reference guide string length ranges from 2 to 16 characters. The default values for 32 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 33
by comparing nonzero IP octets. For example, an ACL of 192.168.64.0 enables access by any hosts that start with the specified octets. The system variables: sysDescr = FC Switch sysLocation = End User Premise sysContact = Field Support. authTraps = 1 (ON) Fabric OS 5.x command reference guide 33 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 34
configured yet Community 6: FibreChannel (ro) No trap recipient configured yet SNMP access list configuration: Entry 0: Access host subnet area 192.168.64.0 (rw)] Entry 1: No access host configured yet Entry 2: No access host configured yet Entry 3: No access host configured yet Entry 4: No - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 35
HP Advanced Zoning, which is included within the Base Configuration Services and bundled with each B-series switch the primary FCS switch. Operands This methods: • A switch domain and port area switch:admin> aliadd "array1", "1,2" switch:admin> aliadd "array2", "21:00:00:20:37:0c:72:51" switch - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 36
See also aliCreate aliDelete aliRemove aliShow 36 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 37
argument is required. portID The port ID in its hexadecimal representation Examples To delete a port from an existing group: switch:admin> aliasdelete 0x19c00 aliasDelete: succeeded Exit status 0 nonzero See also aliasJoin aliasShow fabricShow switchShow Successful operation Indicates the - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 38
group: switch:admin> aliasJoin aliasJoin: To add ports to an existing or new multicast group Number of ports in the group: (1..64) [1] 1 by none: (0..1) [1] Add control 0, Del control 0 Lsn control 1 Setting the Routing Bit: (0x0..0xc) [0x0] using FC-4 Device Data ... Setting FC-4 Type: (0x0..0x5d - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 39
Exit status 0 nonzero See also aliasDelete aliasPurge aliasShow fabricShow nsAllShow nsShow Successful operation Indicates the operation has failed Fabric OS 5.x command reference guide 39 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 40
argument is required. groupID It is the group ID in its hexadecimal representation Examples To remove an alias group: switch:admin> aliasPurge 0xfffb00 aliasPurge: succeeded Exit status 0 nonzero See also aliasJoin aliasShow fabricShow switchShow Successful operation Indicates the operation - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 41
group, they are displayed. Operands none Examples To display the entries in the local alias server: switch:admin> aliasShow {AliasID Creator Token [rb, type, grptype, qlfr] Member List fffb00 fffffd [ Successful operation Indicates the operation has failed Fabric OS 5.x command reference guide 41 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 42
alias. Synopsis alicreate "aliName", "member; member" Availability admin NOTE: This command requires HP Advanced Zoning, which is included within the Base Configuration Services and bundled with each B-series switch. Description Use this command to create a new zone alias. The zone alias member - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 43
Examples To create a zone alias: switch:admin> alicreate "array1", "2,32; 2,33; 2,34" switch:admin> alicreate "array2", "21:00:00:20:37:0c:66:23" switch:admin> alicreate "loop1", "4,5[0x02]; 6,7[0xEF]; 5,4" See also aliAdd aliDelete aliRemove aliShow Fabric OS 5.x command reference guide 43 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 44
Deletes a zone alias. Synopsis alidelete "aliName" Availability admin NOTE: This command requires HP Advanced Zoning license, which is included within the Base Configuration Services and bundled with each B-series switch. Description Use this command to delete a zone alias. This command changes the - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 45
admin NOTE: This command requires HP Advanced Zoning license, which is included within the Base Configuration Services and bundled with each B-series switch. Description Use this command to then removing"1,3; 1,4" succeeds but removing "1,4; 1,3" fails. Fabric OS 5.x command reference guide 45 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 46
Examples Remove a world wide name from "array1": switch:admin> aliremove "array1", "3,5" switch:admin> aliremove "array1", "21:00:00:20:37:0c:76:8c" switch:admin> aliremove "array1", "0xEF" See also aliAdd aliCreate aliDelete aliShow 46 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 47
HP Advanced Zoning license, which is included within the Base Configuration Services and bundled with each B-series switch be issued only from the primary FCS switch. Operands This command has the following switch:admin> alishow "arr*" alias: array1 21:00:00:20:37:0c:76:8c alias: array2 21:00:00:20: - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 48
See also aliAdd aliCreate aliDelete aliRemove 48 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 49
manual.) The default parameters are optimal for most SAN applications; typically, customers do not need to use this command. When used with no arguments, this command displays a list of APT policies supported on this switch static routes are supported only with this support static routes. DLS - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 50
. See dlsSet for the definition of a fabric event. This policy does not support static routes. DLS always is enabled and the DLS setting cannot change with this then change it from an exchange-based to a device-based policy: switch:admin> aptpolicy Current Policy: 3 3: Default Policy 1: Port Based - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 51
See also dlsReset dlsSet dlsShow switchDisable Fabric OS 5.x command reference guide 51 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 52
all, implicit order is FCAP followed by DH-CHAP; for example, in authentication negotiation FCAP is given priority over DH-CHAP on the local switch, however a responder can still select DH-CHAP. -g Sets DH group. Values 0 to 4 and "*" are valid values. DH group 0 is called NULL DH. A user can - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 53
switch:admin> authutil --set -a dhchap Authentication is set to dhchap. To set both protocols in order of fcap,dhchap: switch:admin > authutil --set -a all Authentication is set to fcap,dhchap. To set DH group 3: switch:admin> authutil --set -g 3 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 54
until this test is completed. This command is supported on the SAN Switch 2/8V, SAN Switch 2/16V, SAN Switch 2/32, Core Switch 2/64, and SAN Director 2/128. This command is not supported on the 4/16 SAN Switch, SAN Switch 4/32 and 4/256 SAN Director, which use the Condor ASIC. Operands This command - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 55
Examples To test backplane connections on an HP StorageWorks Director: switch:admin> backplanetest -ports 1/16, 18, 20 -payload 2048 -verbose 1 Running : DATA TIMEOUT XMIT See the HP StorageWorks Fabric OS 5.x diagnostics and system error messages reference guide for more information. See also - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 56
backport Tests for backend ASIC-to-ASIC links. Synopsis backport [-nframes count][-ports itemlist][-lb_mode mode][-fr_type type][-extonly mode] Availability admin Description Use this command to test the backplane routing and virtual channel (VC) allocation. This test applies to single blade as well - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 57
of frames to each link. Examples To test for backend ASIC pair links: switch:admin> backport -ports 1/1-1/3 -nframes 10 One moment please ... backport running... PORT_STOPPED XMIT See the HP StorageWorks Fabric OS 5.x diagnostics and system error messages reference guide for more information. - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 58
the banner operand, the valid length is 116 characters. This operand is optional. Examples To set a new banner for a switch: switch:admin> bannerset "My banner" switch:admin> bannerSet Please input context of security banner (press "." RETURN at the beginning of a newline to finish input): Do - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 59
admin Description Use this command to display the contents of the banner. Operands none Examples To display the banner for a switch: switch:admin> bannershow Banner: Do not log into this switch if you are not an authorized administrator. See also bannerSet Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 60
a port, with the least significant bit in each row representing port 0, 32, 64, and so on. For more information on reading hexadecimal bit maps, see the HP StorageWorks Fabric OS 5.x administrator guide. NOTE: The output from this command varies, depending on switch type. Operands none Examples To - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 61
the previous example, from a switch with 128 ports, the member ports consist of ports 7, 13, 42, 84, 85, and 86. The final Member Ports bit set represents the embedded port (frames sent to be handled by firmware) and is typically set. See also portRouteShow Fabric OS 5.x command reference guide 61 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 62
admin NOTE: This command is available only on the HP StorageWorks SAN Directors. Description Use this command to enable or disable blade Beaconing mode only takes over the port LEDs; it does not change the switch's functional behavior. The normal flashing LED pattern (associated with an active, - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 63
taken offline. If the switch was connected to a fabric through this blade, the remaining switches reconfigure, and this switch will configure based on blade disables. NOTE: A blade cannot be disabled or enabled when the switch is disabled or when the blade itself is disabled (using slotOff), faulted - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 64
Examples To disable blade 2 and then verify: switch:admin> bladedisable 2 Blade 2 is being disabled...Done switch:admin> slotshow Slot Blade Type ID Status 1 SW BLADE 2 ENABLED 2 10 SW BLADE 2 ENABLED See also bladeEnable portDisable portEnable slotOff switchShow 64 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 65
for ports that do not initialize. NOTE: A blade cannot be disabled or enabled when the switch is disabled or when the blade itself is disabled (using slotOff), faulted, powered off, or 6 CP BLADE 1 ENABLED 7 SW BLADE 2 ENABLED (continued on next page) Fabric OS 5.x command reference guide 65 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 66
8 UNKNOWN 9 UNKNOWN 10 UNKNOWN VACANT VACANT VACANT switch:admin> bladeenable 4 slBlade 4 is being enabled...Done switch:admin> slotshow Slot Blade Type ID Status 1 SW BLADE 2 ENABLED 2 UNKNOWN VACANT 3 UNKNOWN VACANT 4 SW BLADE 2 ENABLED 5 CP BLADE 1 ENABLED 6 CP BLADE - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 67
in the nonvolatile storage on the slot during burn-in. NOTE: HP StorageWorks recommends running the burninErrClear command prior to running diagSetBurnin and diagSetCycle. To clear burn-in errors from slot 2. switch:admin> burninErrClear 2 See also burninErrShow Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 68
following operand: slotNum A nonzero value that specifies the slot number from which to display burn-in errors. Examples To display burn-in errors from slot 2: switch:admin> burninErrShow 2 See also burninErrClear 68 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 69
power-on self-test (POST) phase II each time a switch blade is powered on. The mode becomes active as soon preserves the errors prior to returning a board for service. For multibladed products, this is the independent blade, the diagnostic burn-in level: switch:admin> burninlevel -show Burnin level - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 70
the burn-in status of a single slot. If not specified, all slots are displayed. Examples To display the burn-in status for all slots: switch:admin> burninstatus Slot State Status Run 1 ABORT PASS 3 2 ABORT PASS 3 3 ABORT PASS 3 4 ABORT FAIL 3 Cmd TotCmds PID 18 41 916 18 41 920 18 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 71
is supported on the SAN Switch 2/8V, SAN Switch 2/16V, SAN Switch 2/32, Core Switch 2/64, and SAN Director 2/128. This command is not supported on the 4/16 SAN Switch, SAN Switch 4/32 and 4/256 SAN Director, ) will be used. See itemList for more information. Fabric OS 5.x command reference guide 71 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 72
Examples To verify CAM is functioning correctly: switch:admin> camtest -txports 1/1 Running camtest Test Complete: "camtest" Pass 1 of 1 Duration 0 hr, 0 min CAMSTAT DIAG-CANTXMIT See the HP StorageWorks Fabric OS 5.x diagnostics and system error messages reference guide for more information. See - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 73
supported on the SAN Switch 2/8V, SAN Switch 2/16V, SAN Switch 2/32, Core Switch 2/64, and SAN Director 2/128. This command is not supported on the 4/16 SAN Switch, SAN Switch 4/32 and 4/256 SAN Director firmware sets up the hardware for the BISR/BIST operation and checks the results. If the done bit - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 74
a bad buffer. 3. For each of the 11 possible offsets for each ASIC X in the switch: a. Write a 64-byte pattern in the central memory. b. Read X from all ASIC Y in the switch. c. For ASIC X, ensure: • Interrupt status bits are set. • The error type is buffer number error. • The port number in error - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 75
in the switch: a. Write a 64-byte pattern in the central memory. b. Read X from all ASIC Y in the switch. c. For all ASIC Y, ensure: • interrupt status bits set. • 9, QUAD_RAMP, is used. For a complete list of supported data patterns, run the dataTypeShow command. Some common settings are guide 75 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 76
Examples To test the ASIC central memory: switch:admin> centralmemorytest -ports 1/0-1/15 Running centralmemorytest Test Complete: "centralmemorytest" Pass 1 of 1 Duration 0 hr, 0 See the HP StorageWorks Fabric OS 5.x diagnostics and system error messages reference guide for more information - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 77
portLoopbackTest portRegTest spinSilk sramRetentionTest Fabric OS 5.x command reference guide 77 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 78
configuration information. Synopsis cfgactvshow Availability all users NOTE: This command requires HP Advanced Zoning, which is included within the Base Configuration Services and bundled with each B-series switch. Description Use this command to display the effective zone configuration information - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 79
HP Advanced Zoning, which is included within the Base Configuration Services and bundled with each B-series switch be issued only from the primary FCS switch. Operands This command has the following required new zones to the configuration "Test_cfg": switch:admin> cfgadd "Test_cfg", "redzone; - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 80
cfgRemove cfgSave cfgShow 80 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 81
Availability admin NOTE: This command requires HP Advanced Zoning, which is included within the Base Configuration Services and bundled with each B-series switch. Description Use this command to clear Defined zoning configuration only? (yes, y, no, n): [no] n Fabric OS 5.x command reference guide 81 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 82
See also cfgDisable cfgEnable cfgSave 82 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 83
HP Advanced Zoning, which is included within the Base Configuration Services and bundled with each B-series switch the change to be preserved across switch reboots, it must be saved to only from the primary FCS switch. Operands This command has the three zones: switch:admin> cfgcreate "USA_cfg", " - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 84
See also cfgAdd cfgClear cfgDelete cfgDisable cfgEnable cfgRemove cfgSave cfgShow 84 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 85
HP Advanced Zoning, which is included within the Base Configuration Services and bundled with each B-series switch can be issued only from the primary FCS switch. Operands This command has the following operand: Examples To delete a zone configuration: switch:admin> cfgdelete "USA_cfg" See also - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 86
Disables a zone configuration. Synopsis cfgdisable Availability admin NOTE: This command requires HP Advanced Zoning, which is included within the Base Configuration Services and bundled with each B-series switch. Description Use this command to disable the current zone configuration. The fabric - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 87
admin NOTE: This command requires HP Advanced Zoning, which is included within the Base Configuration Services and bundled with each B-series switch. Description Use this command is in effect Updating flash ... See also cfgClear cfgDisable cfgSave cfgShow Fabric OS 5.x command reference guide 87 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 88
configuration. Synopsis cfgremove "cfgName", "member [; member ...]" Availability admin NOTE: This command requires HP Advanced Zoning, which is included within the Base Configuration Services and bundled with each B-series switch. Description Use this command to remove one or more members from an - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 89
cfgDelete cfgDisable cfgEnable cfgSave cfgShow cfgTransAbort cfgTransShow Fabric OS 5.x command reference guide 89 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 90
zone configuration to flash memory. Synopsis cfgsave Availability admin NOTE: This command requires HP Advanced Zoning, which is included within the Base Configuration Services and bundled with each B-series switch. Description Use this command to save the current zone configuration. The defined - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 91
See also cfgAdd cfgClear cfgCreate cfgDelete cfgDisable cfgEnable cfgRemove cfgShow cfgTransAbort cfgTransShow Fabric OS 5.x command reference guide 91 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 92
. Synopsis cfgshow ["pattern"][, mode] Availability all users NOTE: This command requires HP Advanced Zoning, which is included within the Base Configuration Services and bundled with each B-series switch. Description Use this command to display zone configuration information. If no operand is - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 93
:02 1,2 21:00:00:20:37:0c:76:22 21:00:00:20:37:0c:76:28 zone: Red_zone 1,0 21:00:00:20:37:0c:76:85 21:00:00:20:37:0c:71:df To display only configuration names: switch:admin> cfgshow "*" cfg: USA1 Blue_zone cfg: USA_cfg Red_zone; Blue_zone Fabric OS 5.x command reference guide 93 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 94
See also cfgAdd cfgClear cfgCreate cfgDelete cfgDisable cfgEnable cfgRemove cfgSave cfgTransAbort cfgTransShow 94 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 95
HP Advanced Zoning, which is included within the Base Configuration Services and bundled with each B-series switch be issued only from the primary FCS switch. Operands This command has the following optional switch:admin> cfgsize Zone DB max size - 127726 bytes committed - 8812 transaction - 0 switch - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 96
cfgShow 96 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 97
HP Advanced Zoning, which is included within the Base Configuration Services and bundled with each B-series switch switch in the fabric when this command is run, the transaction on the other switch issued only from the primary FCS switch. Operands This command has the transaction: switch:admin> - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 98
current zoning transaction. Synopsis cfgtransshow Availability all users NOTE: This command requires HP Advanced Zoning, which is included within the Base Configuration Services and bundled with each B-series switch. Description Use this command to display the ID of the current zoning transaction - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 99
HP StorageWorks SAN Director 2/128 supports options 1 through 4 and HP StorageWorks 4/256 SAN Directors support options 1 and 5: 1. One 128-port switch (blade ID 4, 17 on slots 1 through 4 and 7 through 10; blade ID 5, 16 on slots 5 and 6) 2. Two 64-port switches used as a guide to re-establishing - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 100
7 through 10; blade ID 5 on slots 5 and 6) 5 One 256-port switch (blade ID 17, 18 on slots 1 through 4 and 7 through 10; blade ID 16 on slots 5 and 6) Examples To display the current configuration option on an HP StorageWorks SAN Director 2/128 and to change the option: 100 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 101
Supported Options (With Blade ID 5 on slots 5-6 Option 1: One 128-port switch (Blade ID 4, 17 on slots 1-4, 7-10, Blade ID 5, 16 on slots 5-6) Option 2: Two 64-port switches (Blade ID 4 on slots 1-4, 7-10, Blade ID 5 on slots 5-6) Option 3: Two 64-port switches the number of switches and the Blade - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 102
]: ckonchad File Name [config.txt]: Password: Upload complete Are you sure you want to continue? (Y/N): y Current Option changed to 2 Restoring switch 0 configuration to factory defaults... done. (Telnet connection goes down at this point.) See also configDownload configUpload slotShow 102 Fabric OS - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 103
the chassis. In the HP StorageWorks Core Switch 2/64 and HP StorageWorks SAN Director 2/128, there are two logical switches associated with a single chassis name to "dilbert": switch:admin> chassisname dilbert Please wait while committing configuration... switch:admin> chassisname dilbert See also - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 104
in hexadecimal. 2 Object type: CHASSIS, FAN, POWER SUPPLY, SW BLADE (switch), CP BLADE (control processor), WWN (world wide name), or UNKNOWN. Object part number (up to 20 characters): Part Num: xxxxxxxxxxxxxxxxxxxx 13 Externally supplied serial number (up to 20 characters): Serial Num: - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 105
Examples To display all FRUs for a switch: Fabric OS 5.x command reference guide 105 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 106
switch:user> chassisshow Chassis Backplane Revision: 1C SW BLADE Slot: 3 Header -180 60-0001532-03 1013456800 Day: 12 Month: 6 Year: 2001 Day: 15 Month: 7 Year: 2001 28 days 16 days 555-374757 234-294-12345 2734658 A.00 CP BLADE Slot: 6 Header Version: 1 Power Consume Factor: -40 Factory - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 107
: Factory Part Num: Factory Serial Num: Manufacture: Update: Time Alive: Time Awake: ID: Part Num: 1 -50 20-123456-12 B014934500 Day: 6 Month: 7 Year: 2001 Day: 15 Month: 7 Year: 2001 88 days 16 days 456-777888 230-290-12370 (output truncated) See also slotShow Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 108
the specified blade slot. NOTE: The output of this command is only for support use only. Operands This command has the following operands: [slotnumber/]chipnumber filter To display the port registers of a chip: switch:admin> chipregshow 1/1 ffffffff See also minisPropShow 108 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 109
be executed on an enabled switch. You must first disable the switch using the switchDisable command. This command is not supported on the 4/16 SAN Switch, SAN Switch 4/32 and 4/256 SAN Director, which use the Condor to be used. The default seed value is 0. Fabric OS 5.x command reference guide 109 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 110
Examples To run the data-retention test on the central memory SRAMS: switch:admin> cmemretentiontest --slot 3 Running cmemretentiontest Test Complete: cmemretentiontest Pass 2 of 2 Duration 0 hr, 2 See the HP StorageWorks Fabric OS 5.x diagnostics and system error messages reference guide for more - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 111
Multiplexed 4-bit CMI bit in any ASIC pair. The CMI is used to send transmission requests or completion messages between the ASIC transmitter and receiver. NOTE: This command is not supported on the 4/16 SAN Switch, SAN Switch 4/32 and 4/256 SAN Director using a bit map as follows: 1 CMI data - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 112
Examples To run a CMI test between two ASIC pairs: switch:admin> cmitest -txports 3/0-3/7 -rxports 3/8-3/15 Running cmitest Test Complete: cmitest Pass 1 of 1 Duration DIAG-INTNIL See the HP StorageWorks Fabric OS 5.x diagnostics and system error messages reference guide for more information. See - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 113
wide name • HP Advanced Zoning configuration • Security parameters and policies • User account passwords • Switch PID format by the system. To avoid unexpected switch behavior, reboot the system after executing on an enabled switch. You must first disable the switch using the switchDisable - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 114
Examples To restore the system configuration to default values: switch:admin> configdefault Committing Configuration ...done. See also agtCfgDefault configure switchDisable switchEnable 114 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 115
switch switch are ignored download a switch configuration file and enabled. The FTP service is widely available on UNIX necessary. The SSH service is available on switch has not been disabled. • The host name is not known to the switch switch configuration file. • The FTP server is the switch is - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 116
up to 8 minutes to download. The download process is additive; that is, the lines read from the file are added to the current switch configuration. This enables you to change a single configuration variable by downloading a file with a single line. All other variables remain unchanged. The R_A_TOV - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 117
from host "citadel", using account "jdoe", and file "config.txt": switch:admin> configdownload -p ftp "citadel","jdoe","config.txt","passwd" Committing configuration... complete To download the same configuration file using SCP: switch:admin> configDownload -p scp "citadel","jdoe","config.txt" jdoe - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 118
: NOTE: Not all values displayed are applicable to all system models and configurations. switch:admin> configshow diag.postDisable: 0 fabric.domain: 1 fabric.ops.BBCredit: 16 fabric.ops.E_D_TOV: 2000 fabric.ops.R_A_TOV: 10000 fabric.ops.dataFieldSize: 2112 fabric.ops.max_hops: 7 fabric - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 119
switch:admin> configshow diag.postDisable: 0 fabric.domain: 1 fabric.ops.vc.linkCtrl: 0 fabric.ops.vc.multicast: 7 fabric.ops.wan_tov: 0 fc4.fcIp.address: 192.168.65.62 fc4.fcIp.mask: 255.255.255.0 fcAL.fanFrameDisable: 0 fcAL.useAltBBCredit: 0 lcdContrast: 128 licenseKey: none rpc. - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 120
might have to be installed from the distribution media and enabled. The FTP service is widely available on UNIX hosts but less so on Windows hosts. The fail for the following reasons: • The host name is not known to the switch. • The host IP address cannot be contacted. • The user does not have - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 121
The second section contains general switch configuration variables, such as jdoe", and file "config.txt": switch:admin> configupload "citadel","jdoe","config.txt configuration file using SCP: switch:admin> configupload -p switch.txt Password: xxxxxxxx upload complete Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 122
See also configDefault configDownload configShow configure 122 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 123
Switch fabric settings • Virtual channel settings • Zoning operation parameters • RSCN transmission mode • Arbitrated loop parameters • System services • Portlog events settings • Application attributes NOTE: If executed on an enabled switch switch . Switch fabric from one switch to another - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 124
number 1 varies R_A_TOV number 10000 E_D_TOV * 2 to 120000 E_D_TOV number 2000 1000 to R_A_TOV / 2 WAN_TOV number 0 0 to R_A_TOV / 0 0 or 1 BB Credit number 16 1 to 27 Insistent Domain ID Mode boolean 0 0 or 1 Descriptions of the switch fabric setting fields are as follows: - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 125
each parameter. To reduce problems, the configuration utility support remote fabrics that involve ATM gateways, which don't support class F traffic. The formats are as follows: 0 Native PID format (16 based, 16 port format), for fabrics with legacy low-count-port switches. 1 Core guide 125 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 126
NOTE: An HP Extended Fabrics license is required to set this mode. BB Credit current domain setting for the switch is insistent: that is, remains the same over switch reboots, power cycles, CP failovers, firmware downloads, and fabric reconfigurations. If a switch does not get the selected - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 127
7 RSCN transmission modes Field Type End-device RSCN Transmission Mode number Domain RSCN to End-device for switch IP address or name change number Default Range 1 0 to 2 0 0 to 1 Descriptions of the or absence of new or pre-existing devices. Fabric OS 5.x command reference guide 127 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 128
service support RPC. On most UNIX-based systems (HP-UX, Irix, Linux, Solaris, and so on.) the command to retrieve the information is rusers. See your local system documentation for the appropriate usage of this or an equivalent command. Used to enable or disable the telnet interface to a switch - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 129
boolean Default 0 off Range 0, 1, 2 on/off NOTE: The secure protocols must not be enabled before setting SSL attributes correctly. Operands none Fabric OS 5.x command reference guide 129 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 130
: (1000..5000) [2000] 5000 WAN_TOV: (0..30000) [0] 0 MAX_HOPS: (7..19) [7] Data field size: (256..2112) [2112] Sequence Level Switching: (0..1) [0] 1 Disable Device Probing: (0..1) [0] Switch PID Format: (1..2) [1] Per-frame Route Priority: (0..1) [0] BB credit: (1..16) [16] Insistent Domain ID Mode - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 131
send RSCN?: (0..1) [0] Do Not Allow AL_PA 0x00?: (0..1) [0] System services(yes, y, no, n): [no] yes rstatd(on, off): [off telnetd (on, off): [on] Portlog events enable (yes, y, no, n): [no] yes start(a switch start or re-start event ) (on, off): [on] disable(a port is disabled ) (on, guide 131 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 132
This command verifies the intended functional operation of the switch by sending frames from port M's transmitter and looping them back through an external fiber cable into port N's receiver, thus exercising all the switch components, from the main board, to the media, to the fiber cable, to - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 133
with the results of portLoopbackTest and spinSilk can be used to determine which components of the switch are faulty. It is also possible to use loopback modes 3 and 5 to further isolate ) loopback 3 Silkscreen loopback 5 Internal (parallel) loopback Fabric OS 5.x command reference guide 133 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 134
will be used. See itemList for more information. Examples To run a functional test of all the ports on a switch: switch:admin> crossporttest -ports 1/0-1/15 Running crossporttest Ports Segmented (0) Executing test ... Test Complete: "crossporttest" Pass 10 of 10 Duration 0 hr, 0 min & 8 sec - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 135
cmemRetentionTest cmiTest itemList portLoopbackTest portRegTest spinSilk sramRetentionTest Fabric OS 5.x command reference guide 135 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 136
stream types used in diagnostic commands. There are 20 different sample data types. The command displays an data streams you can use with diagnostics: switch:admin> datatypeshow Pattern type example BYTE_FILL WORD_FILL 5e bd 7b f6 ec d8 b0 60 c0 11 55 16 fc d7 17 65 a9 87 5f 44 be 5a d0 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 137
primary FCS switch and distributed to the fabric. It might take up to 64 seconds for the switches in the fabric to be synchronized. If the switches in zone support. If the switch is operating in FICON Management Server mode (fmsmode), setting the date is subject to the director clock alert guide 137 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 138
quotation marks. This operand is optional. Examples To display the current date and time and then modify it: switch:admin> date Fri Jan 29 17:01:48 UTC 2000 switch:admin> date "0227123003" Thu Feb 27 12:30:00 UTC 2003 See also errShow ficoncupset ficoncupshow portLogShow tsClockServer tsTimeZone - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 139
to view the debug and verbosity levels. Module names are case sensitive. This operand is optional. Examples To display information about a specific module named NS: switch:admin> dbgshow NS Module NS, debug level = 1, verbose level = 1 See also setDbg Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 140
. If no operand is specified, the default is to clear all bad port flags. Examples To clear the diag software flag: switch:admin> diagclearerror 1 0x1bcb (fabos): Switch: 0, Error DIAG-CLEARERR, 3, Pt5 Sl1 Ch0 Qd1 Diagnostics Error Cleared Err# 0120041 0105 See also none 140 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 141
a list of diagnostic commands, with descriptions: switch:admin> diagcommandshow bladepropshow display blade properties chippropshow display grammar information minispropshow display mini-switch ASIC property minisregshow display contents of mini-switch registers. ptbufshow dump port - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 142
required for this command to take effect. NOTE: This command disables POST on both Core Switch 2/64 logical switches. Operands none Examples To disable the POST during future powerons: switch:admin> diagdisablepost Config update Succeeded Diagnostic POST is now disabled. See also diagEnablePost 142 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 143
and POST Phase II tests system functionality. NOTE: This command disables POST on both Core Switch 2/64 logical switches. Operands none Examples To enable the POST during future power-ons: switch:admin> diagenablepost Config update Succeeded Diagnostic POST is now enabled. See also diagDisablePost - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 144
diagEnv Diagnostic debug parameters management package. Synopsis diagsetdebug value diagdebughelp diagsetdebugnoncheck value diagsetdebugnorestore value diagsetfaillimit value diagsetfrcerr value diagshowusr ... more commands ... Availability admin Description All of diagnostic parameters can be set - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 145
Examples To display the values of the diagnostic parameters: switch:admin> diagshowusr Name Environment USR_DILATION DIAG_USR_DLY_DILATION USR_MEMDLY DIAG_USR_MEMDLY USR_SEED DIAG_USR_SEED USR_SPECIAL DIAG_USR_SPECIAL (output truncated) See also none Value 1 10 0x0 0x0 Fabric OS 5.x - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 146
This operand is optional. If no operand is specified, the current value is displayed. Examples To change the fail limit from 1 to 5: switch:admin> diagfaillimit -show Fail Limit is 1. switch:admin> diagfaillimit 5 Fail Limit is now 5. Config update Succeeded See also none 146 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 147
HP customer support if you wish to use these operands. Operands This command has the following operand: command Specify a command name to display more detailed information. Examples To display diagnostic command information: switch ) See also none Fabric OS 5.x command reference guide 147 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 148
diagnostics. Specify -show to display the current loop ID. If no operand is specified, the current value is displayed. Examples To display the loop ID: switch:admin> diagloopid -show FL mode Loop ID is 125. Notes Currently, no FL_Port mode tests exist. 148 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 149
.burnin.nExec instead of Burnin passnum. Operands none Examples To display the diagnostic mode: switch:admin> diagModeShow diag.mode* parameters saved in flash: diag.mode.burnin = 0 diag nExec = 0 Silkworm Mode = OFF Disable Modes Print = OFF Fabric OS 5.x command reference guide 149 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 150
See also burninLevel setEsdMode setGbicMode setSplbMode 150 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 151
. POST mode modifies the behavior of the diagnostics daemon program to inhibit testing of switch blades when the system is first powered on or a new blade is added. NOTE then disable the POST test: switch:admin> diagpost Diagnostic POST is currently disabled. switch:admin> diagpost 1 Config update - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 152
operand to display the current mode setting. If no operand is specified, the current value is displayed. Examples To view the current retry mode value: switch:admin> diagretry -show Diagnostic Retry Mode is currently enabled. 152 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 153
want to use both commands. NOTE: HP StorageWorks recommends running the burninErrClear command prior to running to current burn-in script. Examples To set the burn-in script and mode: switch:admin> diagsetburnin --slot 1 -current existing script is: /fabos/share/switchess.sh reference guide 153 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 154
interactive session. If all parameters are used, variables can be updated manually. In interactive mode, the current value, default value, and description does not require a reboot to take effect. NOTE: HP StorageWorks recommends running the burninErrClear command prior to running diagSetBurnin and - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 155
Examples To update diagnostic command parameters: switch:admin> diagsetcycle switchburnin.sh -show CURRENT - KEYWORD : DEFAULT 1 - number_of_runs : 1 2 - vib : 2 10 50 - txd_nframes : 50 200 - xpt_nframes : 200 20 - bpt_nframes : 20 50 - slk_nmegs : 50 30 - bpt_all_nframes: 30 50 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 156
is optional. Specify this operand to display the current mode setting. This operand is optional. If no operand is specified, the current value displays. Examples switch:admin> setesdmode -show Esd Mode is 0 (Disabled). See also spinSilk 156 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 157
default value is 0. This operand is optional. Examples To display diagnostic status on a switch blade: switch:admin> diagshow Diagnostics Status: Fri Feb 08 15:25:24 2002 Slot: 1 UPORTS Port OK UP 2G Auto ...... (output truncated) See also itemList Fabric OS 5.x command reference guide 157 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 158
the current mode setting. If no operand is specified, the current value is displayed. Examples To enable show-time mode: switch:admin> diagshowtime Show Time mode is 0 (Disabled). switch:admin> diagshowtime 1 Config update Succeeded Show Time mode is now 1 (Enabled). 158 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 159
test methods used. Operands This command has the following operands: value -show Specify a bit mask for tests to skip. If specified or no value is given, the current skip the current skip test flags: switch:admin> diagskiptests -show Skip tests is 1. Fabric OS 5.x command reference guide 159 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 160
Specifies the slot to display. If omitted, all blades in the system are assumed. Examples To display currently running diagnostic tests: switch:admin> diagstatus Diagnostic status for slot: 1. Diag executing "NONE" Diagnostic status for slot: 2. Diag executing "NONE" Diagnostic status for slot - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 161
on all slots in the logical switch. This operand is optional. Examples To stop burn-in mode on a switch: switch:admin> diagstopburnin --slot 1 No 42:18 Switch: 0, Error DIAG-MANUAL1, 1, " 1 Starting switchess ... Err# 0140042 0100:101:000:001:24:37: 0xc84 (fabos): Dec 20 08:57:27 Switch: 0, Error - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 162
the fabric cannot handle occasional routing changes correctly. DLS is not supported in certain routing policies. See aptPolicy for more information on routing To disable the dynamic load sharing option: switch:admin> dlsreset Committing configuration...done. switch:admin> dlsshow DLS is not set See - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 163
paths to a remote switch, traffic is shared among all the paths. Load sharing is recomputed when a switch is booted up or with this setting. NOTE: DLS is not supported in certain routing policies. See aptPolicy for more dynamic load sharing option: switch:admin> dlsset switch:admin> dlsshow DLS - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 164
routes are never moved to maintain optimal balance. See dlsSet for a description of load sharing. Operands none Examples To display the current DLS option setting: switch:admin> dlsshow DLS is set See also dlsSet dlsReset 164 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 165
the DNS parameters. The domain name service parameters are the domain name and the system: switch:admin> dnsconfig Enter option 1 Display Domain Name Service (DNS) configuration parameters saved successfully Enter option 1 Display Domain Name Service (DNS) configuration 2 Set DNS configuration 3 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 166
See also configDownload configUpload firmwareDownload ipAddrSet ipAddrShow 166 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 167
switch enclosure. Currently, supported attributes are the vendor-specific enclosure identifier and the identifier of the enclosure interface to which the switch which the switch is attached. Examples To display the identifier of the enclosure interface to which the switch is attached: switch:admin> - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 168
processor (CP). Synopsis errclear Availability admin Description Use this command to clear all internal and external error log messages for all switch instances on this CP. Operands none Examples To clear the error log messages: switch:admin> errclear See also errDump errShow 168 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 169
characters are allowed. Examples To display the start and end delimiter: switch:admin> errdelimiterset delimiter start string: delimiter end string: To change the start and end delimiter (with sample output): switch:admin> errdelimiterset -s "Start" -e "End" Start:2003/03/10-09: - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 170
messages in reversed order. If this option is omitted, the messages display in the normal order. Examples To display the error log, without pagination: switch:user> errdump Version: 4.4.0 2004/07/14-22:24:08, [HAMK-1003], 1,, INFO, switch1, Heartbeat up 2004/07/14-22:24:47, [FSSM-1002], 2,, INFO - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 171
See also errDelimiterSet errFilterSet errShow Fabric OS 5.x command reference guide 171 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 172
minimum severity of the message to pass through the filter. Valid values are "INFO", "WARNING", "ERROR", and "CRITICAL". Examples To display the current filter settings: switch:admin> errfilterset console: filter severity = WARNING To set the filter severity level for the console - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 173
errModuleShow Displays all the defined error log modules. Synopsis errmoduleshow Availability user Description Use this command to display a list of all defined error log modules. Operands none Fabric OS 5.x command reference guide 173 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 174
Examples To display a list of all defined error log modules: switch:user> errmoduleshow KT UT TRCE KTRC LOG CDR BLPU PISP PIXE EGR BL PIC PS RTE AS AUTH BLDE BLM BPRT CER CFLD CFMN CHPS - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 175
Fabric OS 5.x command reference guide 175 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 176
for the message Security audit logged. AUDIT displays in the field. Severity of the message. Valid values include INFO, WARNING, ERROR, and CRITICAL. Switch name for the generator of this message, or "chassis". Message body. Delimiter string for the end of a message. Operands This command has the - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 177
Examples To display the error log, with pagination: switch:user> errshow Version: 4.4.0 2004/07/14-22:24:08, [HAMK-1003], 1,, INFO, switch1, Heartbeat up Type via SERIAL. Type to continue, Q to stop: See also errDelimiterSet errDump errFilterSet Fabric OS 5.x command reference guide 177 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 178
exit command is an accepted synonym for logout, as is pressing Ctrl-D at the beginning of a line. Operands none Examples To exit from a shell session: switch:admin> exit Connection to host lost. See also logout 178 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 179
received T3 Trunk Target: Link reset done on slave I4 Trunk Initiator: Link reset done on slave List IU list pointer Fabric OS 5.x command reference guide 179 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 180
is security authenticating ECP RJT or retires exceeded Segmented due to duplicated WWN Segmented due to E_Port isolation nbrWWN Neighboring switch's WWN nbrPort Neighboring switch's port lr_tid Link reset timer identifier and current state. red_ports All E_Ports that are connected to the same - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 181
: switch:admin> fabportshow 4/14 Fabric Port Information Port: 62 State: P3 List: 0x10068418 List Count: 0 Flags: 0x280120 nbrWWN: 10:00:00:60:69:80:06:cf red_ports: 10 11 62 63 Open commands pending No commands pending See also portShow Fabric OS 5.x command reference guide 181 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 182
Fabric Controller Trunk Parameters Return Address Identifier Get Address Identifier Inquiry Command Used internally for fabric application (not a SW_ISL) Get Route Entry Exchange Credit Parameters Firmware Notification Operands none 182 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 183
Examples To display the retry count of Fabric OS commands: switch:user> fabretryshow SW_ISL E_Ports 21 31 40 44 ELP EFP HA_EFP DIA RDI BF RSCN 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 See also fabStatsShow Fabric OS 5.x command reference guide 183 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 184
fabricLog Displays (all users) or manipulates (admin) the fabric log. Synopsis fabricLog -s | -c | -d | -e | -r size Availability all users admin Description Use this command to display, clear, disable, enable, or resize the fabric log. Operands This command has the following operands: -s | -- - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 185
and *Action Xid S, P Sn,Pn Port 11955:655 SCN Switch Online F2,NA F2,NA NA NA 11955:657 *Start 2 Receive F2,P2 F2,P2 21 switch:admin> fabriclog -r 64 Warning: This command will clear the logs. Are your sure you want to do the resize [y/n]? y switch:admin> fabriclog -s Time Stamp Input - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 186
mode ] Availability all users (display current setting) admin (modify current setting) Description Use this command to set principal switch selection mode for the switch. The implementation of the fabricPrincipal command is based solely on mechanisms specified in the Fibre Channel standards. These - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 187
To enable the principal selection mode setting and force fabric rebuild: switch:admin> fabricprincipal -f 1 Principal Selection Mode enabled (Forcing fabric rebuild) See also fabricShow Fabric OS 5.x command reference guide 187 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 188
none Examples The following example illustrates a fabric of four switches. "sw180" is the principal switch. Three of the switches are configured to run IP over Fibre Channel. switch:admin> fabricshow Switch ID Worldwide Name Enet IP Addr FC IP Addr Name 64: fffc40 10:00:00:60:69:00:06:56 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 189
the fabric state information: switch:admin> fabstateshow Time Stamp Input and *Action S, P Sn,Pn Port Xid 11955:655 SCN Switch Online F2,NA F2, ELP ACC Receive F2,P2 F2,P2 21 0x277 switch:admin> fabstateclear switch:admin> fabstateshow Time Stamp Input and *Action S, P Sn, - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 190
F2,P1 F2,P2 21 11957:87 0x277 ELP ACC Receive F2,P2 F2,P2 21 switch:admin> fabstateresize 64 Warning: This command will clear the logs. Are your sure you want to do the resize [y/n]? y switch:admin> fabstateshow Time Stamp Input and *Action Xid S, P Sn,Pn Port 190 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 191
See also fabricLog fabStateClear fabStateShow Fabric OS 5.x command reference guide 191 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 192
fabStateShow Displays the fabric state information. Synopsis fabstateshow Availability all users Description Use this command to display the queue of fabric state information logged by the fabric. NOTE: This command is obsoleted by fabricLog -s. Operands none Examples To display the fabric state - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 193
Time Stamp Input and *Action S, P Sn,Pn Port Xid 11955:655 SCN Switch Online F2,NA F2,NA NA NA 11955:657 *Start 2 * F_S_TOV Timer F2,NA F2,NA NA NA 11955 Send F2,P3 F2,P3 40 0x294 (output truncated) See also fabPortShow fabStateClear fabricLog Fabric OS 5.x command reference guide 193 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 194
all users Description Use this command to display the statistics for the fabric. The information appears as follows: • Number of times a switch domain ID has been forcibly changed • Number of E_Port offline transitions • Number of fabric reconfigurations • Number of fabric segmentations due to - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 195
Examples To display the fabric statistics: switch:admin> fabstatsshow Description Count Domain ID forcibly changed: 0 E_Port offline transitions: 0 Reconfigurations : 0 ECP Error: 0 Duplicate WWN: 0 Eport Isolated: 0 See also fabRetryShow Fabric OS 5.x command reference guide 195 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 196
Fabric Switch State Structure Information State: D0 Stage: warm done Rdi Receive Timer: 0x10069400, IDLE STATE Unconfirmed Sw Timer: 0x10069508, IDLE STATE NTP Timer: 0x100695b8, IDLE STATE ME Timer: 0x10069610, IDLE STATE Principal Domain: 2 Upstream Port: 64 Principal - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 197
: 0 EFP update port: 2 FWN frames pending 0 test check point: No check point set fabric license: TRUE fabric EFP version: 7 last message: 20:30:29.826 *Snd inquiry (4) NA NTP ports online: RSCN domain recovery list: no domain RSCN's to recover reachable domains: 1 3 4 3 domains - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 198
disable a nonfaulty fan unit by setting the RPM speed to 0. NOTE: This command is not available on nonbladed systems except for the HP StorageWorks SAN Switch 4/32. Operands This command has the following operand: unit Specify the fan's unit number to disable. View the fan unit numbers using the - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 199
command is not available on nonbladed systems except for the StorageWorks SAN Switch 4/32. Operands This command has the following operand: unit Specify the a fan unit: switch:admin> fanenable 1 Fan unit 1 has been enabled See also fanDisable fanShow Fabric OS 5.x command reference guide 199 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 200
, the last known fan speed is displayed. NOTE: The output from this command varies depending on switch type and number of fans present. Operands none Examples To display information on the fans in the system: switch:admin> fanshow Fan #1 is OK, speed is 2721 RPM Fan #2 is OK, speed is 2657 RPM - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 201
. If POST has been disabled using the diagDisablePost command, then fastBoot is the same as reboot. Operands none Examples To perform a reboot without executing POST: switch:admin> fastboot See also diagDisablePost diagEnablePost reboot Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 202
using the switchShow command. • WWNs (for example, "10:49:00:00:00:20:3f:2e"). See faZoneCreate for more details on the use of WWNs in Fabric Assist example, "H{1,2}"). Examples To add aliases for some disk arrays to "Blue_fazone": switch:admin> fazoneadd "Blue_fazone", "array3; array4; array5" - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 203
To add another target member to "Blue_fazone": switch:admin> fazoneadd "Blue_fazone", "10:49:00:00:00:20:3f:2e" See also faZoneCreate faZoneDelete faZoneRemove faZoneShow Fabric OS 5.x command reference guide 203 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 204
"2,12; 2,14; 10:00:00:60:69:00:00:8a" would contain devices connected to switch 2, ports 12 and 14, and the device with a WWN of "10:00:00:60:69 be enabled using the cfgEnable command. For the change to be preserved across switch reboots, it must be saved to flash memory using the cfgSave command. - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 205
ports using the switchShow command. • WWNs (for example, "10:49:00:00:00:20:3f:2e"). • Fabric Assist zone alias names. • Exactly one Fabric Assist host switch:admin> fazoneCreate "Red_fazone", "H{1,0}; loop1" switch:admin> fazoneCreate "Blue_fazone", "H{1,1}; array1; 1,2; array2" switch:admin - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 206
must be saved to flash memory using the cfgSave command. NOTE: When security is enabled, this command can be issued only from the primary FCS switch. Operands The following operand is required: fazonename Specify the name of the zone to be deleted, in quotation marks. Examples To delete a Fabric - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 207
the change to be preserved across switch reboots, it must be saved to be issued only from the primary FCS switch. Operands The following operands are required: WWNs (for example, "10:49:00:00:00:20:3f:2e"). See faZoneCreate for more details on the use switch:admin> fazoneremove "Blue_fazone", "array2 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 208
See also faZoneAdd faZoneCreate faZoneDelete faZoneShow 208 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 209
security is enabled, this command can be issued only from the primary FCS switch. Operands This command has the following optional operands: pattern Specify a value to Assist zones beginning with the letters A through C: switch:admin> fazoneshow "[A-C]*" fazone: Blue_fazone 1,1; array1; 1,2; - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 210
and the destination identifier is either source or destination. The echo ELS might not be supported on all devices. In such cases, the response could be either an ELS reject or a request timeout. By default, fcPing sends five ELS ECHO requests to each port. NOTE: When a device does not respond - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 211
16 "pad" bytes, which are used to fill out the request frame payload that is sent. This is useful for diagnosing data-dependent problems Examples switch:admin> fcPing 10:00:00:00:c9:29:0e:c4 21:00:00:20:37 :00:00:20:37:25:ad 1012/1136/1442 usec Pinging 21:00:00:20:37:25:ad:05 [0x211e8] with 12 bytes - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 212
To display one device that accepts the request and another device that does not respond to the request: switch:admin> fcPing 0x020800 22:00:00:04:cf:75:63:85 Source: 0x20800 Destination: 22:00:00:04:cf:75:63:85 Zone Check: Zoned - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 213
fcpLogClear Availability admin Description Use this command to clear the debug information logged by FCPD. Operands none Examples To clear the FCPD debug information log: switch:admin> fcplogclear See also fcpLogDisable fcpLogEnable fcpLogShow Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 214
fcpLogDisable Availability admin Description Use this command to disable the debug information logged by FCPD. Operands none Examples To disable the FCPD debug information log: switch:admin> fcpLogDisable See also fcPing fcpLogEnable fcpLogShow 214 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 215
to enable the debug information logged for FCPD. Debug information logging is enabled by default. Operands none Examples To enable the FCPD debug information log: switch:admin> fcpLogEnable See also fcPing fcpLogDisable fcpLogShow Fabric OS 5.x command reference guide 215 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 216
the FCPD debug information log: switch:admin> fcpLogShow Time Stamp Event 3436 2 :0 :0 :0 :0 22:34:14.232 FlshOrProbe 26 1 459 80 :0 :0 :0 :0 22:34:14.232 PrbMsg 26 1 494 0 :0 :0 :0 :0 :34:14.236 ElsRsp 26 1 1606 11ace :2000000 :20 :0 :980000 22:34:14.238 SndPRLI 26 1 2026 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 217
See also fcPing fcpLogDisable fcpLogEnable Fabric OS 5.x command reference guide 217 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 218
for bladed systems. Use switchShow to list valid ports. This operand is required. Examples To display the FCP probe information: switch:admin> fcpprobeshow 4/4 port 52 is L-Port and it is online. nodes probed: 2 successful PLOGIs: 2 successful PRLIs: 2 successful INQUIRies: 2 successful - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 219
See also portLoginShow portLogShow Fabric OS 5.x command reference guide 219 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 220
to its slot for bladed systems. Use switchShow to list valid ports. This operand is required. Examples To display the FCP RLS information: switch:admin> fcprlsshow 2/5 0xda 0xdc link fail 0 0 loss sync 5 3 loss sig 0 0 prtc err 0 0 bad word 525 330 crc err 0 0 See also portLoginShow - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 221
> fdmicacheshow Switch entry for domain 3 state: known version: v310 wwn: 10:00:00:60:69:90:03:c7 HBAs: 10:00:00:00:c9:25:9b:96 Ports: 1 10:00:00:00:c9:25:9b:96 Total count of devices on the switch is 1 See also fdmiShow Fabric OS 5.x command reference guide 221 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 222
on remote switches. Operands none Examples To display FDMI information on a local switch: switch:admin> Supported Speed: 0x00000001 Port Speed: 0x00000001 Frame Size: 0x00000800 HBA attributes: Node Name: 20 **CT_TEST 1** Firmware Version: 03814101 OS Name and Version: Window 2000 Max CT Payload - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 223
Local Port database contains: 10:00:00:00:c9:25:9b:96 Remote HBA database contains no entry. Remote Port database contains no entry. See also fdmiCacheShow Fabric OS 5.x command reference guide 223 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 224
devices that are not removed from the RNID database. Examples To clear the RLIR database: switch:user> ficonclear RLIR successfully clear local RLIR Database. To clear RNID database: switch:user> ficonclear RNID successfully clear not current entries from local RNID Database. See Also ficonHelp - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 225
mode ASM Active=saved mode DCAM Director clock alert mode ACP Alternate control prohibited HCP Host control prohibited Examples To enable FMS mode for the switch: switch:admin> ficoncupset fmsmode enable fmsmode for the switch is now Enabled To set ASM bit in the mode register for the - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 226
Description Use this command to display FICON-CUP (Control Unit Port) parameters for a switch. Operands The following operands are supported: fmsmode modereg Display the FICON Management Server (FMS) mode for the switch. Display the FICON-CUP mode register. When parameter is modereg, one of the - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 227
To display ASM bit in the mode register for the switch: switch:user> ficoncupshow modereg ASM ASM --1 See Also ficoncupset Fabric OS 5.x command reference guide 227 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 228
list of FICON support commands, with descriptions. Operands none Examples To display a list of FICON commands: switch:admin> ficonhelp ficonshow Node Identification Data) for FICON devices connected to the local switch. ficonshow RNID fabric Displays all RNID entries within the fabric. - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 229
ficonshow ILIR ficonshow ILIR fabric ficonclear RLIR ficonclear RNID Displays all ILIR (Implicit Link Incident Record) entries within the local switch. Displays all ILIR entries within the fabric. Clears the RLIR entries from the local RLIR database Clears the 'not current' entries from the local - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 230
the command displays the members of the named database that are local to the switch on which the command was issued. If the fabric operand is present, it not current. 0x40 Indicates the node ID of the storage port for RNID switch for RLIR is not valid. 0x50 Indicates the node ID of the channel - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 231
individual switch. Same as Link Incident Type. Indicates the link incident type as one of the following: • Bit-error- updates and other FC-4s including FCP and updates. 0x80 FC-4 support not specified. 0xa0 Reserved. 0xc0 Reserved. 0xe0 Vendor specific. Byte 5.x command reference guide 231 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 232
Switch node WWN Switch Port WWN Switch WWN Tag TS Format 232 control unit support only. 0x09 Reserved. 0x10 Switch, if it is a switch device; switch. 0xPN If switch has registered with the channel, PN represents the FL port number. Displays the switch chassis part number. Displays the 24-bit - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 233
switch on which the command is issued displays. Examples To display the local RNID database: switch :admin> ficonshow RNID { {Fmt Type PID Registered Port WWN Registered Node WWN flag Parm 0x18 N 502b00 50:05:07:64:01:00:15:8d 50:05:07:64 50:05:07:64:01:40:0f:ca 50:05:07:64:00:c1:69: - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 234
:00:60:69:80:1e:4f Conditional 0x18 N 531800 50:05:07:64:01:40:13:70 20:18:00:60:69:33:33:33 Conditional } The LIRR database has 5 entries. To display the local SwitchRNID database: switch:admin> ficonshow SwitchRNID { {Switch WWN flag Parm 10:00:00:60:69:80:1e:4e 00 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 235
2e00 Switch Port WWN Switch Node WWN Flag Node Parameters 20:2e:00:60:69:80:1e:4e 10:00:00:60:69:80:1e:4e 0x00 0x200a2e Switch Part Number: 060-0001501-05 Switch Serial Number: 0FT02X801E4E Domain: 20480 } } The local RLIR database has 1 entry. Fabric OS 5.x command reference guide 235 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 236
FL2L0001071 {Listener Port Type Listener PID Listener Port WWN N 0x502b00 50:05:07:64:01:00:15:8d } } {FRU Failure [3]: Power Supply[4] failure occurred on Mon Jan 13 12:11:38 2003 Fmt Protocol Domain Fabric WWN Switch WWN 0x18 FICON 80 10:00:00:60:69:33:33:33 10:00: - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 237
List B 9 Zone A&B match and AL_PA match List B 10 Zone A|B match and AL_PA match Frozen 11 Zone A|B match and AL_PA match Discard Fabric OS 5.x command reference guide 237 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 238
not supported on the HP StorageWorks 4/8 or 4/16 SAN switch, the HP StorageWorks SAN Switch 4/32, or the HP StorageWorks 4/256 SAN Director, which DIAG-FLTXMIT DIAG-NUMTEST See the HP StorageWorks Fabric OS 5.x diagnostics and system error messages reference guide for more information. See also - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 239
firmware is stored, in case the primary partition is damaged. To maintain the integrity of the firmware the primary partition (with new firmware) to the secondary and commits the new firmware to both partitions of the new version of the firmware: switch:admin> firmwarecommit Validating primary - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 240
See also firmwareDownload firmwareRestore 240 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 241
. CAUTION: For each non-director-class switch in your fabric, complete all firmware download changes before issuing the firmwareDownload command on the next switch to ensure a nondisruptive download. NOTE: See the HP StorageWorks Fabric OS 5.x procedures user guide for information about limitations - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 242
autoreboot mode. After downloading firmware, the system must be rebooted. If single-CP mode is enabled and this operand is not specified, the user must issue the reboot command manually to activate the downloaded image. If autoreboot mode is enabled, the switch reboots automatically after the - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 243
following can cause the download to fail: • Host is not known to the switch • Host cannot be reached by the switch • User does not have permission on host • The pfile does not exist host • Running firmwareDownload during POST • A loss of power to the switch Fabric OS 5.x command reference guide 243 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 244
See the HP StorageWorks Fabric OS 5.x diagnostics and system error messages reference guide for more information. See also firmwareCommit firmwareDownloadStatus firmwareRestore firmwareShow reboot version 244 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 245
of a firmware download. CP. Operands none Examples To display the status of a firmware download: switch:admin> firmwaredownloadstatus [1]: Tue Jan 18 13:21:25 2004 cp1 Tue Jan 18 13:24:45 2004 cp1: Standby CP booted up with new firmware. [5]: Tue Jan 18 13:24:51 2004 cp0: Active CP forced failover - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 246
. This step will take up to 30 minutes. [7]: Tue Jan 18 13:31:20 2004 cp0: Firmwaredownload has completed successfully on Standby CP. [8]: Tue Jan 18 13:31 [9]: Tue Jan 18 13:33:54 2004 cp0: Standby CP booted up with new firmware. [10]: Tue Jan 18 13:33:56 2004 cp0: Firmwarecommit has started on both - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 247
it returns with an error code. Operands none Examples To restore the former active firmware image: switch:admin> firmwarerestore Restore old image to be active ... Restore both primary and secondary . Please wait ... See also firmwareCommit firmwareDownload Fabric OS 5.x command reference guide 247 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 248
and remote CPs. Operands none Examples To display the firmware version of a single-CP system: switch:admin> firmwareshow Primary partition: v5.0.1 Secondary Partition: v5.0.1 To display the firmware version of a dual-CP system: switch:admin> firmwareshow Local CP (Slot 5, CP 1): Active Primary - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 249
to verify the functional operation of the switch by sending ELS ECHO frames from the switch F_Port transmitter and receiving ELS ECHO ACC from the N_Port device into the ... 0x78, 0x78, 0x78, 0x78, ... 0xbc, 0xbc, 0x23, 0x47, ... 0x25, 0x7f, 0x6e, 0x9a, ... Fabric OS 5.x command reference guide 249 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 250
words in the test packet payload. If pattern_size is omitted, the default value is 512. Examples To run fportTest on a switch: switch:admin> fporttest -ports 1/0-1/15 Running fPortTest ....... Test Complete: "fporttest" Pass 10 of 10 Duration 0 hr, 0 min & 1 sec (0:0:0:127). passed. Diagnostics - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 251
PORT_M2M PORT_STOPPED PORT_WRONG RXQ_FRAME_ERR RXQ_RAM_PERR STATS STATS_C3FRX STATS_FRX STATS_FTX TIMEOUT XMIT See the HP StorageWorks Fabric OS 5.x diagnostics and system error messages reference guide for more information. See also crossPortTest itemList loopPortTest portTest spinFab Fabric OS - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 252
to guide the supported value; it specifies the replacement of the WWN card. Examples To replace the world wide name card: switch Core Switch WWN Card Removal and Replacement document. Do you wish to continue [y/n]? y Backing up WWN card data, please wait about 25 seconds for further instruction - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 253
re-enter the frureplace command and follow the instructions to complete the operation. Please enter the word `continue' after the new WWN card has been installed: continue Restoring the information to the replacement FRU now, please wait about 20 seconds to complete Verifying the replacement FRU now - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 254
TRUE if the domain of the local switch is currently confirmed. isl_ports Bit map of all the ISL ports. Bit positions correspond to the default areas of the ports. Bit 0 refers to default area of the switch, bit 1 refers to default area 1, and so forth. trunk_ports Bit map of all the trunk slave - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 255
semaphore ID. event_sch FSPF scheduled events bit map. Operands none Examples To display FSPF protocol information: switch:admin> fspfshow version = 2 = 0x100507a8 lsrDelayTo = 5000 lsrDelayCount = 1 ddb_sem = 0x1003e6e8 fabP: event_sch = 0x0 Fabric OS 5.x command reference guide 255 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 256
See also bcastShow topologyShow uRouteShow 256 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 257
(alarms deactivated). This operand is optional. Examples To enable alarms in Fabric Watch: switch:admin> fwalarmsfilterset Committing configuration...done. FW: Alarms are disabled switch:admin> fwalarmsfilterset 1 Committing configuration...done. FW: Alarms are enabled See also fwAlarmsFilterShow - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 258
to display whether alarm filtering is enabled or disabled. Operands none Examples To display the status of alarm filtering in Fabric Watch: switch:user> fwalarmsfiltershow FW: Alarms are enabled switch:user> fwalarmsfiltershow FW: Alarms are disabled See also fwAlarmsFilterSet 258 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 259
licensed Fabric Watch classes. See fwConfigure for a list of classes. Operands none Examples To initialize all classes under Fabric Watch: switch:admin> fwclassinit fwClassInit: Fabric Watch is updating... fwClassInit: Fabric Watch has been updated. See also fwConfigReload fwConfigure fwShow Fabric - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 260
a new Fabric Watch configuration file from a host. Operands none Examples To reload the saved Fabric Watch configuration: switch:admin> fwconfigreload fwConfigReload: Fabric Watch configuration reloaded See also configDownload configUpload fwClassInit fwConfigure fwShow 260 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 261
and modify threshold information for the Fabric Watch configuration. Switch elements monitored by Fabric Watch are divided into classes classes and areas are provided in Table 13. NOTE: Not all platforms support fans or power supplies. If you attempt to configure values for these reference guide 261 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 262
Table 13 fwConfigure fabric watch classes and areas (continued) Class Area Port Link loss Sync loss Signal loss Protocol error Invalid words Invalid CRCS RXPerformance TXPerformance State Changes Fabric E_Port downs Fabric reconfigure Domain ID changes Segmentation changes Zone changes - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 263
RXPerformance TXPerformance State Changes AL_PA Performance Monitor Invalid CRCS EE Performance Monitor Invalid CRCS RXPerformance TXPerformance Filter Performance Monitor Customer Define Fabric OS 5.x command reference guide 263 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 264
Table 13 fwConfigure fabric watch classes and areas (continued) Class Area Security Telnet Violations HTTP Violations API Violations RSNMP Violations WSNMP Violations SES Violations MS Violations Serial Violations Front Panel Violations SCC Violations DCC Violations Login Violations Invalid - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 265
envTemp005 enabled 36 C started 10:28:59 on 02/01/2000 0 C Informative 1 : refresh 2 : disable a threshold 3 : enable a threshold 4 : advanced configuration 5 : return to previous page Select choice => : (1..5) [5] switch:admin> fwconfigure --disable --port 1 Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 266
See also fwClassInit fwConfigReload fwShow 266 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 267
command has the following operand: --show Displays the current FRU configuration setting. If no operand is specified, the configuration prompt appears. Fabric OS 5.x command reference guide 267 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 268
Examples To change the FRU state alert configuration: switch:admin> fwfrucfg The current FRU configuration: Alarm State Alarm Action Alarm States are: Absent-1, Inserted-2, On-4, Off-8, Faulty-16 Configurable Alarm Actions are: Errlog-1, E-mail-16 Slot Alarm State: (0..31) [0] 3 Slot Alarm - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 269
a summary of Fabric Watch commands: switch:user> fwhelp fanShow fwAlarmsFilterSet fwAlarmsFilterShow fwClassInit persistence time Show sensor readings Set switch status policy parameters Show switch status policy parameters Show overall switch status Show switch temp readings See also none - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 270
a Fabric Watch license. Description Use this command to display or modify the configuration and status of the Fabric Watch e-mail alert in the switch. Switch elements monitored by Fabric Watch are divided into classes, and e-mail alerts are based on the classes. Each class can configure one e-mail - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 271
3 : Enable Email Alert 4 : Send Test Mail 5 : Set Recipient Mail Address for Email Alert 6 : Quit Select an item => : (1..6) [6] 5 (continued on next page) Fabric OS 5.x command reference guide 271 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 272
Mail Config Menu 1 : Environment class 2 : SFP class 3 : Port class 4 : Fabric class 5 : E-Port class 6 : F/FL Port (Optical) class 7 : Alpa Performance Monitor class 8 : End-to-End Performance Monitor class 9 : Filter Performance Monitor class 10 : Security class 12 : FRU Class 13 : Quit Select an - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 273
operand is specified, all ports are displayed. This command has the following operands: --p portNumber Yields a port detail report for a specific port. Fabric OS 5.x command reference guide 273 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 274
ports f Report based on all faulty ports o Report based on all offline ports Examples To retrieve a port detail report: switch:user> fwportdetailshow --s h Port Detail Report Switch Name: switch IP address: 10.255.255.255 Port Exception report [by Healthy] Report time: 06/07/2004 03:11:44 PM - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 275
:user> fwportdetailshow --s h Port Detail Report Switch Name: switch IP address: 10.255.255.255 Port Exception report [by Healthy] Report time: 06/07/2004 03:11: E HEALTHY 001:11 029 E HEALTHY 001:11 031 F HEALTHY 001:11 See also switchStatusShow Fabric OS 5.x command reference guide 275 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 276
: switch:user> fwsamshow Port# Type Total Total Down Up Time Down Time Occurrence (Percent) (Percent) (Times) Total Offline Time (Percent) 0 U_PORT 0 0 0 100 1 U_PORT 0 0 0 100 2 U_PORT 0 0 0 100 3 E_PORT 21 0 0 78 4 E_PORT 20 0 0 80 5 U_PORT 0 0 0 100 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 277
period in which a port must be persistently in a state before being actually being recognized as such. Examples To set message levels and port persistence time: switch:user> fwset --port --persistence 18 See also fwShow Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 278
boundary and alarm levels to custom values for all classes and areas in Fabric Watch. Operands none Examples To set alarm levels to custom values: switch:admin> fwsettocustom Committing configuration...done. See also fwSetToDefault 278 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 279
return boundary and alarm levels to defaults for all classes and areas in Fabric Watch. Operands none Examples To return alarm levels to default values: switch:admin> fwsettodefault Committing configuration...done. See also fwSetToCustom Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 280
marked as such. Displays the ports that have all associated thresholds disabled. Examples To display thresholds and port persistence time: switch:user> fwshow 1 : Show class thresholds 2 : Detail threshold information 3 : Show console message level 4 : Show port persistence time 5 : Quit Select an - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 281
RPM envFan002 Env Fan 2 2518 RPM envFan003 Env Fan 3 2481 RPM switch:user> fwshow 1 : Show class thresholds 2 : Detail threshold information 1: Monitored for: 1283 (21 mins) Last checked: 10:50:21 on 02/01/2000 Lower bound: Upper bound: Buffer Size: 0 C 75 C 10 Value history: 33 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 282
Style: Triggered Event 0 occurred 1 time, last at 16:30:17 on 12/09/2011 Event 1 occurred 10 times, last at 16:49:02 on 12/09/2011 * Event 5 occurred 1 time, last at 16:30:23 on 12/09/2011 Callbacks: No callbacks are registered. switch:user> fwshow --port --persistence FW: current port persistence - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 283
commands to be edited. The h command displays the 20 most recent commands typed into the shell; the oldest mode and then use vi commands. The ESC key switches the shell to edit mode. The ENTER key gives none Examples To display previous shell commands: switch:admin> h 1 version 2 switchshow 3 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 284
Description Use this command to disable the High Availability feature in the switch. If the HA feature is already disabled, this command does nothing. Operands none Examples To disable the High Availability feature: switch:admin> hadisable HA is disabled See also haEnable 284 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 285
status of the High Availability feature in the switch. This command displays the following information: • the background health diagnostic has discovered a problem. Failover is disabled until the standby CP Channel addresses configured for the switch. • Additional internal HA state information, - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 286
switch:admin> hadump hashow: Local CP (Slot 6, CP1): Active Remote CP (Slot 5, CP0): Standby, Healthy HA enabled, Heartbeat Up, HA State synchronized ipaddrshow: SWITCH0 Ethernet IP Address: 10.64 Subnetmask: 0.0.0.0 SWITCH1 Ethernet IP Address: 10.64.118.105 Ethernet Subnetmask: 255.255.240.0 Fibre - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 287
in the switch. Synopsis haenable Availability admin Description Use this command to enable the High Availability feature in the switch. If the HA feature is already enabled, this command does nothing. Operands none Examples To enable the High Availability feature in the switch: switch: - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 288
even while traffic is continuing to flow. NOTE: This command is supported only on systems with dual CP cards. Operands none Examples To force the failover of the active CP to the standby CP in the switch: switch:admin> hafailover Local CP (Slot 6, CP1): Active Remote CP (Slot 5, - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 289
The standby CP is running, but the background health diagnostic has discovered a problem with the blade. The logs should be checked to determine the appropriate repair is disruptive. NOTE: This command might not be supported on nonbladed systems. Operands none Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 290
:admin> hashow Local CP (Slot 6, CP1): Active Remote CP (Slot 5, CP0): Standby, Healthy HA Enabled, Heartbeat Up, HA State Synchronized switch:admin> hashow Local CP (Slot 6, CP1): Active Remote CP (Slot 5, CP0): Standby, Failed Backplane PCI fail, severity: CRITICAL HA enabled, Heartbeat Up, HA - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 291
hasyncstart Availability admin Description Use this command to enable the HA state synchronization. Operands none Examples To enable the HA state synchronization: switch:admin> hasyncstart HA State synchronization has started See also haFailover haShow haSyncStop Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 292
temporarily disable the HA synchronization. The next failover that takes place after might be disruptive. Operands none Examples To disable the HA state synchronizing process: switch:admin> hasyncstop See also haFailover haShow haSyncStart 292 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 293
; this can vary, according to: • Login user level • License key • Switch model To access help information for a specific command, enter the command name as Examples To display help information for the passwd command: switch:admin> help passwd See also diagHelp fwHelp licenseHelp perfHelp routeHelp - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 294
dd hh:mm:ss yyyy xx-yyyyyyy-zz or Unknown xxxxxxxxxxxx or Unknown Operands none Examples To display the late FRU insertion or removal event: switch:admin> historylastshow POWER SUPPLY Unit 2 Inserted at Tue Aug 14 15:52:10 2001 Factory Part Number: 60-0001536-02 Factory Serial Number: 1013456800 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 295
that the first set of logs to fill the buffer are preserved. Operands none Examples To change the history mode to first-in from rotating: switch:admin> historymode History Mode is: Rotating. See also historyLastShow historyShow Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 296
historyShow Displays the entire field replaceable unit (FRU) history log. Synopsis historyshow Availability all users Description Use this command to display the entire history log, which records insertion and removal events for blades, power supplies, fans, and world wide name (WWN) cards. Each - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 297
To display the entire contents of the history file: switch:admin> historyshow FAN Unit 3 Removed at Tue Aug 14 10:05:37 1970 Factory Part Number: 20-123456-12 Factory Serial Number: 1013456800 POWER SUPPLY Unit Serial Number: 1013456800 Records: 11 Fabric OS 5.x command reference guide 297 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 298
See also historyLastShow 298 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 299
the URL from which the plug-in can be downloaded. Operands none Examples To display the Java plug-in version: switch:admin> httpcfgshow Current HTTP configuration javaplugin.version = 1,3,1 javaplugin.homeURL = http://java.sun.com/products/plugin See also none Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 300
020 tracing system calls FORKNOEXEC 040 forked but did not exec SUPERPRIV 100 used super-user privileges DUMPCORE 200 dumped core SIGNALED 400 killed by a signal S Process state codes: D uninterruptible sleep (usually IO) R runnable (on run queue) S sleeping T traced or stopped - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 301
the following operand: processID Specify the process name or process ID for the process to display. Examples To display information about process ID 433: switch:admin> i 433 F S UID PID PPID C PRI NI ADDR SZ WCHAN TTY TIME CMD 000 S 0 433 1 0 69 0 - 1283 5c64 ? 00:00:02 fabricd See also - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 302
links might be set to operate in different modes. NOTE: This command is not supported on the HP StorageWorks SAN Switch 4/32 switch and HP StorageWorks SAN Director 2/128 and 4/256 directors that use a Broadcom PHY transceiver. Operands This command has the following operand: interface Specify - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 303
scenario for the ifModeSet command: switch:admin> ifmodeset eth0 Exercise care when using this command. Forcing the link to an operating mode not supported by the network equipment to yes, y, no, n): [no] y Committing configuration...done. See also ifModeShow Fabric OS 5.x command reference guide 303 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 304
or "eth0", where eth is the network interface and 0 is the physical unit. Examples To display the link operating mode for the eth0 Ethernet interface: switch:admin> ifmodeshow eth0 Link mode: negotiated 100baseTx-HD, link ok See also ifModeSet 304 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 305
with FSPF interfaces (E_Ports) on the switch: • The permanently allocated Interface Descriptor Block all the information relating to the switch that is connected to an adjacent switch. This command displays the content of switches. Current state of this interface. This E_Port is used to route - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 306
timer ID. Inactivity timeout value, in milliseconds. When this timeout expires, the adjacency with the neighbor switch is broken and new paths are computed to all possible destination switches in the fabric. Hello timeout value, in milliseconds. When this timeout expires, a Hello frame is sent - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 307
interface information: switch:user> interfaceshow 1/4 idbP = 0x1008b3d0 Interface 4 data structure: nghbP ifNo masterPort defaultCost cost delay lastScn lastScnTime upCount lastUpTime downCount lastDownTime downReason iState = 0x1008c668 = 4 = 4 (self) = 500 = 500 = 1 = 16 = Apr 02 20:01:44 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 308
= 4 remPort = 52 nflags = 0xf initCount = 1 lastInit = Apr 02 20:01:44.460 firstHlo = Apr 02 20:01:44.473 nbstFull = Apr 02 20:01:44.512 delay = 1 lastScn = 16 &dbRetransList = 0x1008c6a0 &lsrRetransList = 0x1008c6c4 &lsrAckList = 0x1008c6e8 inactTID = 0x1008c768 helloTID - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 309
to take effect. In a heterogeneous fabric, several HP features are not available in order to provide maximum compatibility between switches. HP domain IDs must be between 97 and 127 for successful connection to other switches. The firmware automatically assigns a valid domain ID, if necessary, when - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 310
Examples To view and then enable interoperability mode: switch:admin> interopmode InteropMode: Off Usage: InteropMode 0|1 0: to turn it off 1: to turn it on switch:admin> interopmode 1 done. Interopmode is enabled. switch:admin> reboot See also configure 310 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 311
topology change. This command might cause out-of-order delivery of frames during fabric topology changes. Operands none Examples To turn off the IOD option: switch:admin> iodreset switch:admin> iodshow IOD is not set See also iodSet iodShow Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 312
-order delivery of frames during a fabric topology change. In a stable fabric, frames are always delivered in order, even when the traffic between switches is shared among multiple paths. However, when topology changes occur in the fabric (for instance, a link goes down), traffic is rerouted around - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 313
Use this command to display whether the IOD option is enabled or disabled. Operands none Examples To display the current setting of the IOD option: switch:admin> iodshow IOD is not set See also iodReset iodSet Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 314
or control processor (CP). Synopsis ipaddrset [-cp number] [-sw number] Availability admin Description Use this command to set the IP addresses on the switch or CP. If no option is provided on a chassis-based system, the command displays the usage. To set the CP IP address use -cp; to - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 315
See also ipAddrShow Fabric OS 5.x command reference guide 315 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 316
the IP addresses configured in the system. The -cp option displays the CP IP address and the -sw option displays the switch IP addresses. For switches, the command displays the Ethernet IP address, Ethernet subnetmask, Fibre Channel IP address, and Fibre Channel subnetmask. For CPs, the command - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 317
each port on this switch. The WWN to which switch: switch:admin> islshow 1: 33 -> 29 10:00:00:60:69:80:4f:84 switch sp switch sp: 2G bw: 8G TRUNK 3: 41 -> (incompatible) 4: 47 -> (incompatible) 5: 57 -> 25 10:00:00:60:69:80:4f:84 switch sp: 2G bw: 4G TRUNK 6: 60 -> 2 10:00:00:60:69:80:4f:84 switch - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 318
equivalent. • If no slot number is specified, user port lists are specified by area number. For instance, 0, 16, 32 and 1/0, 2/0, 3/0 specify the same ports on a 16-port/blade system. On that same system, 1/0, 16, 32 is not a valid list: even though it's syntax is legal, the ports do not exist. • If - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 319
as spinSilk or crossPortTest, to specify which user-accessible external ports within the current switch (selected during telnet login) are tested. When specified in an item list, cmiTest crossPortTest diagCommandShow portLoopbackTest portRegTest Blade Switch Blade Blade Blade Chassis n.a. Blade - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 320
killTelnet Terminates an open telnet session. Synopsis killtelnet Availability admin Description Use this command to terminate an open telnet session. The killTelnet command is an interactive menu-driven command. Upon invocation, it lists all the current telnet and serial port login sessions. It - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 321
switch:admin> killtelnet Collecting login information....Done List of telnet sessions (3 found) Session No USER TTY IDLE FROM LOGIN@ 0 root0 ttyS0 1:17m - 5:13pm 1 admin0 pts/0 16.00s to terminate (q to quit) q See also none Fabric OS 5.x command reference guide 321 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 322
Use this command to add license keys to the system. Some features of the switch and the fabric to which it is connected are optional, licensed products. Without a license installed for such products, their services are not available. After you enter a license, the licensed product is available - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 323
commands: switch:admin> licensehelp licenseAdd licenseIdShow licenseRemove licenseShow Add a license to this switch Show system license ID Remove a license from this switch Show current licenses See also licenseAdd licenseIdShow licenseRemove licenseShow Fabric OS 5.x command reference guide 323 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 324
Use this command to display the license ID of the system. Some features of the switch and the fabric are optional, licensed products. Without a license installed for such products, the services provided by these features are not available. For dual-domain systems, a single license enables both - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 325
command to remove an existing license key from a switch. The existing license key must be entered exactly as product uninstalled. After removing a license key, the switch must be rebooted. With no license key, licenseShow a license key from the switch: switch:admin> licenseremove "bQebzbRdScRfc0iK" - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 326
is displayed when no licenses are installed. Operands none Examples To display the installed license keys on a switch: switch:admin> licenseshow bQebzbRdScRfc0iK: Web license Zoning license SybbzQQ9edTzcc0X: Fabric license See also licenseAdd licenseHelp licenseIdShow licenseRemove 326 Fabric OS - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 327
port. When executed without arguments, this command displays the current cost of each port on the switch, even those are not ISL's. Active ISLs have an additional suffix of E_PORT attached to their values for all ports on the (logical) switch are displayed. Fabric OS 5.x command reference guide 327 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 328
1000 2 7 1000 2 8 1000 2 9 1000 2 10 1000 2 11 (E_PORT) 2000 (STATIC) 2 12 1000 2 13 1000 2 14 1000 2 15 1000 switch:admin> linkcost 2/4 500 switch:admin> linkcost 2/4 Slot 2 Interface 4 switch:admin> linkcost 2/4 0 Slot 2 Interface 4 See also interfaceShow lSDbShow - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 329
Synopsis login Availability all users Description Use this command to log in to the switch with another user name and password, without first logging out from the original session from the login user: switch:user> login login: admin Password:xxxxxx See also logout Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 330
to open another session before the timeout has completed causes an error message to display. Operands none Examples To log out from an rlogin session: switch:admin> logout Connection to host lost. See also login 330 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 331
The cables and SFPs connected should be of the same technology, meaning that a short wavelength SFPed (switch) port is connected to another short wavelength SFPed (device) port through a short wavelength cable; and for more information on selecting ports. Fabric OS 5.x command reference guide 331 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 332
. Valid values include: 1 for byte (default) 2 for word 3 for quad This operand is optional. Examples To perform a loopback port test: switch:admin> loopporttest -ports 1/0-1/15 Running Loop Port Test ....... Test Complete: "loopporttest" Pass 10 of 10 Duration 0 hr, 0 min & 1 sec (0:0:0:127 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 333
16 lsdbShow display fields Field Description Domain lsrP earlyAccLSRs ignoredLSRs lastIgnored installTime lseFlags uOutIfs uPathCost uOldHopCount uHopsFromRoot mOutIfs Domain number described by this LSR. A (self) keyword after the domain number indicates that LSR describes the local switch - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 334
Table 16 lsdbShow display fields (continued) Field Description parent mPathCost Always 0. ID of this LSR. It is identical to the domain number. ID (domain number) of the switch that originated this LSR. Incarnation number of this LSR. Total length (in bytes) of this LSR. Includes header - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 335
a switch: switch:admin> 0x10053d18 lsAge = 16 reserved = 0 = 284 chksum = 0x8453 linkCnt = 16, flags = 0x0 LinkId = 2, out port = 16, rem port = 48, cost = = 59, cost = 500, costCnt = 0, type = 1 LinkId = 2, out port = 32, rem port = 0, cost = 500, costCnt = 0, type = 1 LinkId = 2, out - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 336
= 500, costCnt = 0, type = 1 2, out port = 46, rem port = 14, cost = 500, costCnt = 0, type = 1 2, out port = 47, rem port = 15, cost = 500, costCnt = 0, type = 1 The local switch has sixteen links in NB_ST_FULL state, all of them are connected to - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 337
admin> memshow total used Mem: 129740800 112562176 Swap: 0 0 switch:admin> memshow -m total used Mem: 123 107 Swap: 0 0 free 17178624 0 free 16 0 shared 0 buffers cached 139264 30396416 shared 0 buffers 0 cached 28 See also saveCore Fabric OS 5.x command reference guide 337 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 338
miniCycle Runs a functional test of internal and external transmit and receive paths at full speed. Synopsis minicycle [--slot slotnumber][-nmegs count][-lb_mode mode][-spd_mode mode][-ports itemlist] Availability admin Description Use this command to verify the intended functional operation of an - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 339
results of portLoopbackTest and spinSilk can be used to determine which components of the switch are faulty. Operands The following operands are optional: --slot slotnumber Specifies the slot Port Loopback (loopback plugs) 2 External (SERDES) loopback Fabric OS 5.x command reference guide 339 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 340
details. If all ports in the ASIC pair are not specified, only paths between selected ports are tested. ASIC-pair 0: -ports 0-15 ASIC-pair 1: -ports 16-31 ASIC-pair 2: -ports 32-47 ASIC-pair 3: -ports 48-63 340 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 341
409). passed. To run a functional test on ports 0, 1, 2, and 8 using port loopback: switch:admin> minicycle -ports 0,1,2,8 -lb_mode 1 Back Plane Loop Back mode is ON. Running mini Cycle One Pass 1 of 1 Duration 0 hr, 0 min & 23 sec (0:0:23:100). passed. Fabric OS 5.x command reference guide 341 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 342
NO_SEGMENT PORT_ABSENT PORT_DIED PORT_ENABLE PORT_M2M PORT_STOPPED PORT_WRONG RXQ_FRAME_ERR RXQ_RAM_PERR STATS STATS_C3FRX STATS_FRX STATS_FTX TIMEOUT XMIT See the HP StorageWorks Fabric OS 5.x diagnostics and system error messages reference guide for more information. 342 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 343
See also backport camTest centralMemoryTest cmemRetentionTest cmiTest crossPortTest itemList portLoopbackTest portRegTest spinSilk sramRetentionTest Fabric OS 5.x command reference guide 343 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 344
. The default is 0 and and designed to operate on fixed-port-count products. Examples To display all index 1 ASIC pair properties: switch:user> minispropshow 1 -all slot: 1, miniS: 0 [2/16] (be,5) (be,4) (be,3) (be,2) (be,1) (be,0) (bi,55) (bi,54) (bi,25) (bi,24) (bi,41 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 345
,23) (bi,22) (bi,11) (bi,10) (bi,59) (bi,58) (fe,11) (fe,10) (fe,9) (fe,8) slot: 1, miniS: 3 [2/16] (be,23) (be,22) (be,21) (be,20) (be,19) (be,18) (bi,7) (bi,6) (bi,27) (bi,26) (bi,43) (bi,42) (fe,15) (fe,14) (fe,13 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 346
Switch WWN Capability Name 10:00:00:60:69:20:15:71 0x0000008f "switch1"* 10:00:00:60:69:00:30:05 0x0000008f "switch2" Capability Bit Definitions: Bit 0: Basic Config Service Supported. Bit 1: Platform Management Service Supported. Bit 2: Topology Discovery Service Supported. Bit - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 347
See also msConfigure msPlMgmtActivate msPlMgmtDeactivate msTdDisable msTdEnable msTdReadConfig Fabric OS 5.x command reference guide 347 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 348
allows a SAN management application to retrieve and administer the fabric and interconnect elements, such as switches. This way of the MS_POLICY configuration. Operands none Examples To display the MS ACL: switch:admin> msconfigure 0 Done 1 Display the access list 2 Add member based on - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 349
consists of (5): { 20:01:00:60:69:00:60:10 20:02:00:60:69:00:60:10 20:03:00:60:69:00:60:10 20:02:00:60:69:00:60:03 20:02:00:60:69:00 msPlatShow msPlClearDB msPlMgmtActivate msPlMgmtDeactivate msTdDisable msTdEnable msTdReadConfig secPolicyShow Fabric OS 5.x command reference guide 349 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 350
switch:admin> msplatshow Platform Name: [9] "first obj" Platform Type: 5 : GATEWAY Number of Associated M.A.: 1 Associated Management Addresses: [35] "http://java .sun.com/products/plugin" Number of Associated Node Names: 1 Associated Node Names: 10:00:00:60:69:20:15:71 Platform - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 351
See also msCapabilityShow msConfigure msPlatShowDBCB msPlClearDB msPlMgmtActivate msPlMgmtDeactivate Fabric OS 5.x command reference guide 351 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 352
to display the control block fields associated with the platform database. Operands none Examples To display the MS platform service database control block: switch:admin> msplatshowdbcb Domain Worldwide Name Retry Count Exchange Status 3: 10:00:00:60:69:51:10:e6 0 0x2 msPlDBCB - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 353
is enabled, this command can be issued only from the primary FCS switch. Operands none Examples To clear the MS platform database: switch:admin> msplcleardb MS Platform Service is currently enabled. This will erase MS Platform Service Database in the entire fabric. Would you like to continue this - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 354
in the fabric boot with the MS platform service enabled. By default, the MS platform service is disabled. Before issuing, run the msCapabilityShow command to verify all switches in the fabric support MS platform service; otherwise, the command fails. NOTE: When security is enabled, this command - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 355
switch. Operands none Examples To deactivate the MS platform service on all switches in the fabric: switch:admin> msplmgmtdeactivate MS Platform Service is currently enabled. This will erase MS Platform Service MS Platform Service in progress...... *Completed deactivating MS Platform Service in the - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 356
; therefore, persistent across power cycles and reboots. If the "ALL" operand is used, this command attempts to disable the topology discovery service on all switches in the fabric. NOTE: When security is enabled, and using the "ALL" operand, this command can be issued only from the primary FCS - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 357
See also msTdEnable msTdReadConfig Fabric OS 5.x command reference guide 357 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 358
the entire fabric. This operand is optional.. Examples To enable the MS topology discovery service on the local switch only: switch:admin> mstdenable Request to enable MS Topology Discovery Service in progress.... done. *MS Topology Discovery enabled locally. To enable MS topology discovery on - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 359
is enabled. Operands none Examples To display the status of the topology discovery service: switch:admin> mstdreadconfig *MS Topology Discovery is enabled. See also msCapabilityShow msConfigure msPlMgmtActivate msPlMgmtDeactivate msTdDisable msTdEnable Fabric OS 5.x command reference guide 359 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 360
Description Use this command to display the status of the system and the login session details. The login session gives details of the following: • CP/switch (or console/serial port) used to log in • The IP address of the current login session for telnet or the name of the current console - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 361
to the local switch, or information about switch. E_Port (interface) on local switch. Domain number of remote switch. E_Port (interface) on remote switch switches directly connected to the local switch: switch:user> nbrstateshow 2/0 Local Domain ID: 1 Local Port Domain Remote Port State 16 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 362
[slotnumber/][portnumber] Availability admin Description Use this command to reset the counters of FSPF frames transmitted and received on each inter-switch link (ISL) or a specific ISL. These counters display using the using the interfaceShow command. Use this command without operands to reset - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 363
10 = 11 = 11 = 12 = 12 = 17 = 17 switch:admin> nbrstatsclear 1/0 switch:admin> interfaceshow 1/0 idbP = 0x10050a38 Interface 0 data structure: nghbP nLsaIn = 0 attHloOut = 0 nHloOut = 0 attLsuOut = 0 nLsuOut = 0 attLsaOut = 0 nLsaOut = 0 Fabric OS 5.x command reference guide 363 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 364
See also interfaceShow portShow switchShow 364 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 365
hexadecimal digits between 0 and ff, with no spaces. PID must begin with 0x or 0X; otherwise, it interprets as an alias. Fabric OS 5.x command reference guide 365 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 366
Name: 22:00:00:04:cf:9f:26:7e Device type: Physical Target Aliases: a320 To display all the device information matching the given WWN: switch:admin> nodefind 20:00:00:e0:8b:01:ce:d3 Remote: Type Pid COS PortName NodeName NL 020eef - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 367
:69:51:0b:ba Permanent Port Name: 20:00:00:e0:8b:01:ce:d3 Device type: Physical Target Aliases: To display all the device information matching the given no match: switch:admin> nodefind abcd No device found. See also aliShow nsAllShow nscamShow nsShow Fabric OS 5.x command reference guide 367 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 368
of the device. Currently, four originations are defined: Physical Device connected to the Nx_Port, using FLOGI to login to the switch Virtual Contrived device by the switch NPV Device connected to the Nx_Port, using FDISC to log in to the switc iSCSI Device connected to the iSCSI port - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 369
with aliases: switch:admin> nsAliasShow Fabric Port Name: 20:02:00:60:69 20:00:00:60:69:00:02:d6; na Fabric Port Name: 20 20:00:00:fa:ce:00:21:1e; na FC4s: FCP [STOREX RS2999FCPH3 MT09] Fabric Port Name: 20 20:00:00:fa:ce:04:83:c9; na FC4s: FCP [STOREX RS2999FCPH3 NS09] Fabric Port Name: 20 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 370
To display local NS information with aliases with -r option: switch:admin> nsAliasShow -r { Type Pid COS PortName NodeName SCR N 021200; 2,3;10:00:00:60:69:00:03:19;30:00:00:60:69:00:03:19; 3 FC4s: FCIP Fabric Port Name: 20:02:00:60:69:01:44:22 Permanent Port Name: 10:00 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 371
To display local NS information with aliases with -r and -t options: switch:admin> nsAliasShow -r -t { Type Pid COS PortName NodeName SCR N 021200; 2,3;10:00:00:60:69:00:03:19;30:00:00:60:69:00:03:19; 3 FC4s: FCIP Fabric Port Name: 20:02:00:60:69:01:44:22 Permanent Port Name: 10 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 372
Description Use this command to display the 24-bit Fibre Channel addresses of all devices in all switches in the fabric. If the type operand 5 = FC-IP type device Other FC-PH types are displayed in the format x ports supporting FC4 code, where x is the number of ports of a type and code is the FC- - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 373
See also nsShow switchShow Fabric OS 5.x command reference guide 373 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 374
if the NS cache manager does not discover new switches or new devices in the fabric. For each remote switch found, the output of this command displays the N for N_Port, NL for NL_Port The 24-bit Fibre Channel address A list of classes of service supported by the device The device's port world wide - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 375
Name: 20:02:00:60:69:00:68:19 Permanent Port Name: 10:00:00:60:69:00:ab:ba Switch entry for with -t option: switch:admin> nscamShow -t nscam show for remote switches: Switch entry for 2 20:02:00:60:69:00:68:19 Permanent Port Name: 10:00:00:60:69:00:ab:ba Device type: Physical Initiator Switch - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 376
nsShow switchShow 376 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 377
command displays information from all switches. Each line of output displays: Type PID COS PortName NodeName TTL SCR Device type Permanent Port Name U for unknown, N for N_Port, NL for NL_Port. 24-bit Fibre Channel address. List of classes of service supported by device. Device port world - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 378
are defined: Physical Device connected to the Nx_Port, using FLOGI to login to the switch Virtual Contrived device by the switch NPV Device connected to the Nx_Port, using FDISC to log in to the switch iSCSI Device connected to the iSCSI port The second part indicates the role of the - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 379
switch:admin> nsShow { Type Pid COS PortName NodeName TTL(sec) N 021200; 2,3;10:00:00:60:69:00:03:19;30:00:00:60:69:00:03:19; na FC4s: FCIP Fabric Port Name: 20 N 021300; 3;10:00:00:60:69:00:02:d6;20:00:00:60:69:00:02:d6; na Fabric Port Name: 20:03:00:60:69:01:44:22 Permanent Port Name: 10 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 380
To display local NS information with -r: switch:admin> nsShow -r { Type Pid COS PortName NodeName SCR N 021200; 2,3;10:00:00:60:69:00:03:19;30:00:00:60:69:00:03:19; 3 FC4s: FCIP Fabric Port Name: 20:02:00:60:69:01:44:22 Permanent Port Name: 10:00:00:60:69 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 381
To display local NS information with -r and -t: switch:admin> nsShow -r -t { Type Pid COS PortName NodeName SCR N 021200; 2,3;10:00:00:60:69:00:03:19;30:00:00:60:69:00:03:19; 3 FC4s: FCIP Fabric Port Name: 20:02:00:60:69:01:44:22 Permanent Port Name: 10:00:00:60 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 382
of classes of service supported by the device The device's port world wide name (WWN) The device's node WWN Physical N_Port or NL_Port WWN The device's type There might be additional lines if the device has registered any of the following information (the switch automatically registers SCSI inquiry - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 383
switch:admin> nszonemember 0x0416e2 3 local zoned members: Type Pid COS SCR PortName NodeName NL 041901; 2,3;10:00:00:00:c9:26:0e:ae;20:00:00:00:c9:26:0e:ae; 3 Fabric Port Name: 20 :00:00:20:37:d9:6b:b3;20:00:00:20:37:d9:6b:b3; 0 FC4s: FCP [SEAGATE ST318304FC 0005] Fabric Port Name: 20:06:00: - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 384
0 FC4s: FCP [SEAGATE ST318304FC 0005] Permanent Port Name: 22:00:00:20:37:d9:61:ac Device type: Physical Target No remote zoned members To display each local device's online zoned device data: switch:admin> nszonemember -a Port: 4 Pid: 0xb00400 Aliases: ix360_131_201_6a Zoned Members: 2 devices - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 385
To display all the unzoned devices in the fabric: switch:admin> nszonemember -u Pid: 0xb01ea9; Aliases: trimm32b_1 Pid: 0xb01eaa; Aliases: trimm32b_2 Pid: 0xb01eab; Aliases: trimm32b_3 Pid 9 unzoned devices in the fabric. See also cfgShow nscamShow nsShow Fabric OS 5.x command reference guide 385 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 386
terminated. NOTE: If the Security option is enabled on the fabric, this command is disabled on all switches except the primary FCS. See the HP StorageWorks Fabric OS 5.x administrator's guide for more information. A new password must follow these rules: • Have 8 to 40 characters • Be different from - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 387
the current password. Examples To change the password for the admin user: switch:admin> passwd "admin" Changing password for admin Enter new password: Re- the new password. See the HP StorageWorks Fabric OS 5.x diagnostics and system error messages reference guide for more information. See also - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 388
not make any retry attempts if there is a timeout or failure. It might fail if a switch along the path is busy, for instance, if a switch is performing a warm recovery or if a switch along the path does not support this feature. NOTE: If the advanced performance tuning (APT) policy in effect on the - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 389
hop from the source switch to the destination switch. In order to from port A on switch X to port B on switch Y might be different switches, or the reverse path might even involve different switches a sequence of switches, ports, or expressed as a sequence of switches, a sequence of output ports - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 390
reporting of basic statistics on every link; default is no. Requests the reporting of extended statistics on every link; default is no. Specifies a sequence of switches or ports that the pathInfo frame should traverse; default is no. Note that if an output port (or area) to the next hop is specified - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 391
the command line (noninteractive mode): switch:admin> pathinfo 91 Target port is basic and extended statistics using interactive mode: switch:admin> pathinfo Max hops: (1..127) [ 2 1G 1000 Port B/s (1s) B/s (64s) Txcrdz (1s) Txcrdz (64s) F/s (1s) F/s (64s) Words Frames Errors E 2 Tx Rx Tx - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 392
) 12 1G 1000 Port 3 12 Tx Rx Tx Rx B/s (1s) 36 76 0 0 B/s (64s) 5 5 5 5 Txcrdz (1s) 0 - 0 - Txcrdz (64s) 0 - 0 - F/s (1s) 1 1 0 0 F/s (64s) 0 0 0 0 Words 240434036 2294316 2119951 2121767 Frames 20025929 54999 162338 56710 Errors - 4 - 0 Hop - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 393
displays output from the latest panic dump file available on the switch. If a panic dump file is specified as an argument, of pdfile * File :/core_files/panic/core.pd1038932352 * * SECTION:PD_MISC * WatchDogRegister=0x0 Section=Startup time: Tue Dec 3 16:06:11 UTC 2002 Kernel= - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 394
See also portLogDump saveCore 394 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 395
, 0x050200 has a domain ID of 5, an area ID of 2, and an AL_PA ID of 0. SourceID and DestID both cannot be 0x000000. Fabric OS 5.x command reference guide 395 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 396
to separate the operands even when using commas. Examples To add an end-to-end monitor to blade 1 port 2: switch:admin> perfaddeemonitor 1/2 "0x050200" "0x1182ef" End-to-End monitor number 0 added. See also perfAddIPMonitor perfAddReadMonitor perfAddRWMonitor perfAddSCSIMonitor perfAddUserMonitor - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 397
. Optionally, a comma can separate the operands. A space is required to separate the operands even when using commas. Examples To add an IP monitor to a port: switch:admin> perfaddipmonitor 1/4 "IP_MONITOR" IP traffic frame monitor #0 added Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 398
See also perfAddEEMonitor perfAddReadMonitor perfAddRWMonitor perfAddSCSIMonitor perfAddUserMonitor perfAddWriteMonitor 398 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 399
. Optionally, a comma can separate the operands. A space is required to separate the operands even when using commas. Examples To add a SCSI read monitor to a port: switch:admin> perfaddreadmonitor 2/4 "SCSI_R" SCSI Read filter monitor #2 added Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 400
See also perfAddEEMonitor perfAddIPMonitor perfAddRWMonitor perfAddSCSIMonitor perfAddUserMonitor perfAddWriteMonitor 400 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 401
can separate the operands. A space is required to separate the operands even when using commas. Examples To add a SCSI read and write monitor to a port: switch:admin> perfaddrwmonitor 2/4 "SCSI_RW" SCSI Read/Write monitor #1 is added Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 402
See also perfAddEEMonitor perfAddIPMonitor perfAddReadMonitor perfAddSCSIMonitor perfAddUserMonitor perfAddWriteMonitor 402 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 403
, a comma can separate the operands. A space is required to separate the operands even when using commas. Examples To add a SCSI traffic frame monitor to a port: switch:admin> perfaddscsimonitor 2/4 "SCSI_FR" SCSI traffic frame monitor #0 added Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 404
See also perfAddEEMonitor perfAddIPMonitor perfAddReadMonitor perfAddRWMonitor perfAddUserMonitor perfAddWriteMonitor 404 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 405
0, [4-63]. Offset 0 is a special case that can be used to monitor the first four bytes SOFx frames. EOF cannot be monitored. Fabric OS 5.x command reference guide 405 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 406
to separate the operands even when using commas. Examples To add a filter-based monitor for all Extended Link Service requests (R_CTL=0x22 and TYPE=0x01) to a port: switch:admin> perfaddusermonitor 1/4 "4, 0xff, 0x22; 12, 0xff, 0x01" User monitor #0 added As a special case, to add a filter-based - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 407
, a comma can separate the operands. A space is required to separate the operands even when using commas. Examples To add a SCSI Write command monitor to a port: switch:admin> perfaddwritemonitor 2/4 "SCSI_W" SCSI Write filter monitor #0 added Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 408
See also perfAddEEMonitor perfAddIPMonitor perfAddReadMonitor perfAddRWMonitor perfAddSCSIMonitor perfAddUserMonitor 408 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 409
none Examples To clear the performance monitoring information from nonvolatile memory: switch:admin> perfcfgclear This will clear Performance Monitoring settings in FLASH. Monitoring configuration cleared from FLASH. See also perfCfgRestore perfCfgSave Fabric OS 5.x command reference guide 409 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 410
are lost using the perfCfgRestore command. Operands none Examples To restore the performance monitoring configuration information from nonvolatile memory: switch:admin> perfcfgrestore This will overwrite current Performance Monitoring settings in RAM. Do you want to continue? (yes, y, no, n): [no - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 411
monitoring configuration to be saved across power cycles. Operands none Examples To save the current performance monitoring configuration to firmware: switch:admin> perfcfgsave This will overwrite previously saved Performance Monitoring settings in FLASH. Do you want to continue? (yes, y, no - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 412
even when using commas. Examples To clear statistics counters for an end-to-end monitor: switch:admin> perfcleareemonitor 1/2 5 End-to-End monitor number 5 counters are cleared switch:admin> perfcleareemonitor 1/2 This will clear ALL EE monitors' counters on port 2, continue? (yes, y, no, n): [no - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 413
See also perfAddEEMonitor perfShowEEMonitor perfMonitorClear Fabric OS 5.x command reference guide 413 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 414
even when using commas. Examples To clear statistics counters for a filter-based monitor: switch:admin> perfclearfiltermonitor 1/2 4 Filter-based monitor number 4 counters are cleared switch:admin> perfclearfiltermonitor 1/2 This will clear ALL filter-based monitors' counters on port 2, continue - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 415
See also perfAddUserMonitor perfShowFilterMonitor perfMonitorClear Fabric OS 5.x command reference guide 415 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 416
count on a particular AL_PA on a port and then clear the CRC count for all AL_PAs on a port: switch:admin> perfclralpacrc 2/15 0x59 CRC error count at ALPA 0x59 on port 31 is cleared. switch:admin> perfclralpacrc 2/15 This will clear all ALPA CRC Counts on port 31 Do you want to continue - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 417
even when using commas. Examples To delete an end-to-end monitor on a port, or all such monitors: switch:admin> perfdeleemonitor 7/2 5 End-to-End monitor number 5 deleted switch:admin> perfdeleemonitor 7/2 This will remove ALL EE monitors on port 2, continue? (yes, y, no, n): [no] y See also - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 418
. Examples To delete filter monitor 4 from a port, and then all filter monitors from the port: switch:admin> perfdelfiltermonitor 2/3 4 The specified filter-based monitor is deleted. switch:admin> perfdelfiltermonitor 2/3 This will remove ALL monitors on port 19, continue? (yes, y, no, n): [no - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 419
NOTE: This command requires a Performance Monitor license. Description Use this command to display the available performance monitoring help commands. Operands none Fabric OS 5.x command reference guide 419 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 420
Examples To display commands related to performance monitoring: switch:admin> perfhelp perfCfgSave Save Performance configuration to FLASH perfCfgRestore FLASH Restore Performance configuration from perfCfgClear Clear Performance settings from FLASH perfClrAlpaCrc Clear ALPA device's CRC - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 421
), filter-based monitors (FLT), and inter-switch link monitors (ISL). Issuing the portStatsClear command end), FLT (filter-based), or ISL (inter-switch link). These values are case sensitive. This switch:admin> perfMonitorClear --class EE 1/2 5 End-to-End monitor number 5 counters are cleared switch - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 422
clear ALL filter-based monitors' counters on port 2, continue? (yes, y, no, y): [no] y To clear statistics counters for an ISL monitor: switch:admin> perfMonitorClear --class ISL 1 This will clear ISL monitor on port 1, continue? (yes, y, no, n): [no] y See also perfAddEEMonitor perfAddIPMonitor - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 423
The IP address of the originator that created the filter monitor Cumulative 64-bit frame count If you do not specify a value for the interval operand ISL monitors, the command displays: Tx_count Num_ports Num_domains Domain_count 64-bit cumulative ISL transmit count for the whole ISL Number of - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 424
follows: --class monitor_class slotnumber portnumber interval The monitor class, which can be one of EE (end-to-end), FLT (filter-based), or ISL (inter-switch link). This operand is required. For bladed systems only, this operand specifies the slot number of the port on which the monitor is to be - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 425
0x00000004d0baed41 0x0000000067229e98 To display filter-based monitor on a port at an interval of every 6 seconds: switch:admin> perfMonitorShow --class FLT 2/5 6 perfmonitorshow 21, 6 0 1 2 3 4 5 6 #Frames #Frames # 204 717 717 717 513 204 Fabric OS 5.x command reference guide 425 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 426
WEB_TOOLS 192.168.169.40 0x0000000000002208 6 SCSI_WR WEB_TOOLS 192.168.169.40 0x000000000000033a To display ISL monitor information on a port: switch:admin> perfMonitorShow --class ISL 1/1 Total transmit count for this ISL: 1462326 Number of destination domains monitored: 3 Number of ports - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 427
ID mask in dd:aa:pp format. Quotation marks are optional. TxDIDMsk represents transmitting destination ID mask. This operand is required. Fabric OS 5.x command reference guide 427 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 428
operands. A space is required to separate the operands even when using commas. Examples To set the overall mask for end-to-end monitors on a port: switch:admin> perfsetporteemask 1/6 "00:00:00" "ff:ff:ff" "00:00:ff" "ff:00:00" Changing EE mask for this port will cause ALL EE monitors - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 429
on a specified port are displayed. CRC count is a 64-bit counter. When the count is over 32 bits, the CRC count value is displayed in hexadecimal; otherwise, count for all AL_PA devices on a port: switch:admin> perfshowalpacrc 2/4 ALPA CRC_ERROR_COUNT 0x01 0 See also perfClrAlpaCrc Fabric - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 430
perfShowEEMonitor Displays end-to-end performance monitor information on a port. Synopsis perfshoweemonitor [slotnumber/]portnumber [interval] Availability all users NOTE: This command requires a Performance Monitor license. This command is deprecated; use perfMonitorShow instead. Description Use - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 431
6m 0 52m 4.6m 0 52m 4.6m 0 52m 4.6m 0 52m 0 To display EE monitors on a port: switch:admin> perfshoweemonitor 4/5 There are 7 end-to-end monitor(s) defined on port 53. KEY SID DID OWNER_APP OWNER_IP_ADDR CRC_COUNT See also perfAddEEMonitor Fabric OS 5.x command reference guide 431 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 432
when using commas. Examples To display filter monitor traffic on a port at an interval of every 6 seconds: switch:admin> perfshowfiltermonitor 2/5 6 perfshowfiltermonitor 21, 6 0 1 2 3 4 5 6 #Frames #CMDs #CMDs #Frames #Frames #CMDs #CMDs 0 0 0 0 0 0 0 26k 187 681 682 682 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 433
179 179 187 200 204 To display filter monitor information on a port: switch:admin> perfshowfiltermonitor 2/5 There are 7 filter-based monitors defined on port 21 the filter-based monitor frame count is displayed in 64-bit format and is cumulative. See also perfAddEEMonitor perfAddIPMonitor - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 434
perfShowPortEEMask Displays the current address mask for end-to-end performance monitors on a port. Synopsis perfshowporteemask [slotnumber/]portnumber Availability all users NOTE: This command requires a Performance Monitor license. Description Use this command to display the current mask shared - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 435
Examples To display the end-to-end mask on a port: switch:admin> perfshowporteemask 2/4 The EE mask onport 20 is set by application NONE TxSID Domain: on TxSID Area: on TxSID ALPA: on RxDID ALPA: on See also perfAddEEMonitor perfDelEEMonitor perfSetPortEEMask Fabric OS 5.x command reference guide 435 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 436
exits with a warning and does not create PKI objects. Operands none Examples To create PKI objects in nonsecure mode: switch:admin> pkicreate Installing Private Key and Csr... Switch key pair and CSR generated... Installing Root Certificate... If run in secure mode, the following error message is - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 437
switch private key, private key pass-phrase, CSR, root certificate, and switch fibre channel switch. If you want secure mode enabled, you will need to get the switch certificate again the following error message is displayed: switch:admin> pkiremove This Switch is in secure mode. Removing Pki objects - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 438
Use this command to display existence of PKI objects, such as switch private key, private key pass-phrase, CSR, root certificate, and switch certificate. Operands none Examples To view PKI objects: switch:admin> pkishow Passphrase : Exist Private Key : Exist CSR : Exist Certificate - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 439
the port number to display, relative to its slot for bladed systems. Use switchShow to list valid ports. Examples To display the AL_PAs of a port: switch:user> portalpashow 4/14 AL_PA type AL_PA type 0xe2 public 0xe4 public AL_PA type See also switchShow Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 440
distance in kilometers displays as measured by timing the return trip of a MARK primitive that is sent and then echoed back to the switch. The supported distance measurement is up to 500 Km. Distance measurement on a link longer than 500 Km might not be accurate. Displays the remaining (unallocated - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 441
. Examples To display the long distance information a port: switch:user> portbuffershow 17 User Port Lx Max/Resv Buffer Needed Link Remaining Port Type Mode Buffers Usage Buffers Distance Buffers 16 - - 0 - - 17 E L1 - 54 54 50km 18 - - 0 - - 19 - - 0 - - 54 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 442
portCamShow Displays port-based filter CAM utilization. Synopsis portcamshow [slotnumber/][portnumber] Availability all users Description Use this command to display the current filter CAM utilization of all ports or one port specified at input. The following information is displayed: SID used - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 443
CAM utilization for all ports on a switch: switch:user> portcamshow Ports of Slot 9 Port SID used DID used SID free DID free 0 0 0 64 512 1 0 0 64 512 2 0 0 64 512 3 0 0 64 512 4 0 0 64 512 5 0 0 64 512 6 0 0 64 512 7 0 0 64 512 8 0 0 63 511 9 0 0 63 511 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 444
portCfg Sets a port's configuration to be disabled or enabled. Synopsis portCfg action [slotnumber/]portnumber [range] mode Availability admin Description Use this command to disable or enable configuration to a certain port or to a range of ports. Operands This command has the following - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 445
Examples To configure a port as RSCN suppressed: switch:admin> portcfg rscnsupr 2/4 --enable switch:admin> portcfgshow [output from other slots suppressed] Ports of Slot 2 0 1 2 3 4 5 6 7 8 9 10 11 where AN:AutoNegotiate, ..:OFF, ??:INVALID. LM:L0.5 Fabric OS 5.x command reference guide 445 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 446
To configure a port as not RSCN suppressed: switch:admin> portcfg rscnsupr 2/4 --disable switch:admin> portcfgshow [output from other slots suppressed] Ports of Slot 2 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Speed AN AN AN AN AN AN AN AN - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 447
To configure a range of ports as RSCN suppressed: switch:admin> portcfg rscnsupr 2/4-7 --enable switch:admin> portcfgshow [output from other slots suppressed] Ports of Slot 2 0 1 2 3 4 5 6 7 8 9 INVALID. LM:L0.5 See also configure portShow switchShow Fabric OS 5.x command reference guide 447 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 448
systems. Use switchShow to list valid ports. Examples To reset a port to factory defaults: switch:admin> portcfgdefault 1/3 See also portCfgEPort portCfgGPort portCfgLongDistance portCfgLPort portCfgPersistentDisable portCfgPersistentEnable portCfgShow portCfgSpeed portCfgTrunkPort 448 Fabric - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 449
segmented. No data traffic between two switches is routed through this port. Fabric switches, the maximum routing paths are currently limited to 16 E_Ports. Changes made by this command are persistent across switch switch:admin> portcfgeport 2/3, 0 To enable a port to become an E_Port: switch - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 450
loop initialization (FL_Port) on the port. A port designated as a G_Port can become an E_Port. Changes made by this command are persistent across switch reboots or power cycles. Operands This command has the following operands: slotnumber portnumber mode For bladed systems only, specify the slot - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 451
across the entire fabric. See the configure command for more information on the core PID format. ISL R_RDY mode sends ELP with Flow Control Mode 02 disable ISL R_RDY mode. Examples To enable ISL R_RDY mode on a port: switch:admin> portcfgislmode 1/3, 1 ISL R_RDY Mode is enabled for port 3. Please - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 452
See also portCfgShow 452 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 453
HP Extended Fabrics license. Description Use this command to allocate enough full-size frame buffers on a particular port to support Reconfigure the port to be a regular switch port. A total of 20 full-size frame buffers are reserved for the HP StorageWorks Fabric OS 5.x command reference guide. The - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 454
of frame buffers. HP StorageWorks SAN Switch 2/8V, 2/16V, and 2/32 switches and HP StorageWorks Core Switch 2/64 and 2/128 directors do not support "buffer limited" mode and can have up to four ports per port group. The 4/8, 4/16, and 4/32 SAN switches and the 4 GB SAN Switch support "buffer limited - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 455
Examples To configure a port to support a 100 km link and be initialized using long-distance link initialization protocol: switch:admin> portcfglongdistance 4/15 L2 1 switch:admin> portshow 4/15 portCFlags: 0x1 portFlags: 0x20001 PRESENT LED portType: 1.1 portState: 2 Offline portPhys: 4 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 456
L_Port and the FLOGI is rejected. The switch never attempts point-to-point (F_Port) supported only on HP StorageWorks SAN Switch 2/8V, 2/16V, 2/32 switches and HP StorageWorks Core Switch 2/64, and HP StorageWorks SAN Director 2/128 and 4/256 directors with SAN Switch 2/16 blades. For other switches - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 457
To configure a port as a locked L_Port: switch:admin> portcfglport 4/15, 1 switch:admin> portcfgshow [output from other slots suppressed] AN:AutoNegotiate, ..:OFF, ??:INVALID. To display the L_Port conditions: switch:admin> portcfglport [output from other slots suppressed] Ports of Slot - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 458
458 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 459
switch reboots, and switch . The switch still runs ports of that switch, and the ports within the switch. Because the default is not allowed if the switch is operating in the FICON that are permanently disabled: switch:admin> portcfgpersistentdisable 9/3 switch:admin> portcfgpersistentdisable Slot 9 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 460
See also ficoncupset ficoncupshow portCfgDefault portDisable portEnable portCfgPersistentEnable portShow switchShow 460 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 461
cycles, switch reboots, and switch enables that switch. The persistent switch disable within the switch. The configuration status for all ports in the switch. The value of YES is that are persistently enabled: switch:admin> portcfgpersistentenable 9/3 switch:admin> portcfgpersistentenable Slot 9 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 462
See also ficoncupset ficoncupshow ficoncupset ficoncupshow portDisable portDisable portEnable portCfgPersistentDisable portCfgShow portShow switchShow 462 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 463
configuration settings are displayed for that switch or for the Core Switch 2/64 logical switch. The following configuration information appears: km, or L2 when the link is up to 100 km, and also supports LE, L0.5, and LD modes. This value is set by the portCfgLongDistance reference guide 463 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 464
a list of valid ports. This operand is optional; if omitted, this command displays information for all ports. Examples To display the configuration settings of a switch: switch:user> portcfgshow Ports of Slot 1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Speed AN AN AN AN AN AN AN AN AN AN AN AN - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 465
To display the configuration settings of a port: switch:user> portcfgshow 4/15 Area Number: 63 Speed Level: AUTO Trunk Port OFF Long Distance See also portCfg portCfgEPort portCfgGPort portCfgLongDistance portCfgLPort portCfgSpeed portCfgTrunkPort Fabric OS 5.x command reference guide 465 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 466
and enabled so that the port comes up with the new speed setting. The configuration is saved in the flash memory and is persistent across switch reboot or power cycle. If the command is specified without an operand, you are prompted to enter the speed value. Press Ctrl+D to cancel the - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 467
a port to be enabled or disabled for HP ISL Trunking license. Synopsis portcfgtrunkport [slotnumber/]portnumber operand is required. Examples To enable a port for trunking: switch:admin> portcfgtrunkport 1/3 0 See also portCfgShow portShow switchCfgTrunk switchShow Fabric OS 5.x - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 468
5. Specify the verbose level to be set for port modules; valid values are 1 to 5. Examples To set debug level and verbose level of port modules: switch:admin> portdebug 3 4 See also dbgShow 468 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 469
this command to disable a port. If the port is connected to another switch, the fabric might reconfigure. If the port is connected to one or list of valid ports. Examples To disable a port: switch:admin> portdisable 2/4 See also portCfgPersistentDisable portCfgPersistentEnable portEnable portShow - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 470
the following indications might be sent to indicate a state transition: RSCN, SNMP trap, Web pop-up window. This command is rejected if the port's switch is disabled, the port's blade is not fully enabled (faulted, powered off, or disabled), or if the port itself is persistently disabled. The front - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 471
states) Loss of synchronization Loss of signal Frames rejected with F_RJT Frames busied with F_BSY Operands none Examples To display error counters for ports on a switch: switch:user> porterrshow frames enc crc too too bad enc disc link loss loss frjt fbsy tx rx in err shrt long eof out c3 fail - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 472
0 0 0 0 0 2.1m 0 2 2 0 0 0 58: 142 141 0 0 0 0 0 2.0m 0 2 2 0 0 0 59: 142 141 0 0 0 0 0 2.0m 0 2 2 0 0 0 60: 29 32 0 0 0 0 0 9.0m 0 1 26 0 0 0 61: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 62: 0 0 0 0 0 0 0 0 0 0 0 1 0 0 63: 28 32 0 0 0 0 0 8.6m 0 1 34 0 0 0 See also portShow portStatsShow 472 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 473
port type. Operands none Examples To display the port status for all ports in the switch. switch:user> portflagsshow Slot Port SNMP Physical Flags 1 0 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT (continued on next page) Fabric OS 5.x command reference guide 473 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 474
4 2 Online 4 3 Online 4 4 Offline 4 5 Offline 4 6 Online 4 7 Online 4 8 Online 4 9 Online 4 10 Online 4 11 Online 4 12 Online 4 13 Online 4 14 Online 4 15 Online See also portShow switchShow In_Sync In_Sync No_Light No_Light In_Sync In_Sync In_Sync In_Sync - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 475
port LEDs in the current switch on and off by setting You must disable the current switch (using the switchDisable command) . You can enable the current switch (using the switchEnable command) to switch are assumed. For more information, see the itemList command. Examples To test port LEDs: switch - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 476
, EXCHBAD FCPH, EXCHFREE NBFSM, DUPEPORTSCN UCAST, RELICPDB See the HP StorageWorks Fabric OS 5.x diagnostics and system error messages reference guide for more information. Operands none Examples To clear the port log: switch:admin> portlogclear switch:admin> portlogshow port log is empty See also - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 477
portlogconfigshow Availability admin Description Use this command to display the current port log configuration. Operands none Examples To display the current port log configuration: switch:admin> portlogconfigshow max portlog entries = 8192 See also portLogResize Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 478
displayed by this command, see the HP StorageWorks Fabric OS 5.x procedures user guide. Operands This command has the following operands is optional. Examples To display the port log for a port: switch:user> portLogDump 20 time task event port cmd args 08:35:27.899 tShell pstate 14 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 479
switch:user> portLogDump 20 time task event port cmd args 08:35:27.899 tShell pstate 14 OL1 08:35:27.899 tReceive pstate 14 ,00050006,02000000 08:35:28.433 tTransmit Tx 14 0 c0fffffd,00fffffd,00050006 See also portLogClear portLogShow upTime Fabric OS 5.x command reference guide 479 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 480
log files in the switch firmware, which can save up HP StorageWorks Fabric OS 5.x procedures user guide for more information. Operands This command has the following operand: portid Specify the area number of port to display. If a port area number is specified, all other ports on the switch - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 481
14 96 03fffffd,00fffffd,00060007,02100060 Tx 14 0 c0fffffd,00fffffd,00060007 ioctl 14 a1 0,0 scn 14 5 See also portLogClear portLogShow upTime Fabric OS 5.x command reference guide 481 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 482
Operands none Examples Display information about port log events: switch:admin> portlogeventshow ID Event-Name Disabled 1 start 0 2 0 13 stats 0 14 scn 0 15 pstate 0 16 reject 0 17 busy 0 18 ctin 0 19 ctout 0 20 errlog 0 21 loopscn 0 (continued on next page - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 483
sn 27 fcin 28 fcout 29 read 30 write 31 err 32 frame 33 msRemQ 34 msRemR 35 nsRemQ 36 nsRemR 37 xfree 41 xerr 42 xstate 43 seq 44 seqst 45 iu 46 payload 47 zone 48 cmd 49 event 50 msg 51 switch 52 ficonq 53 routing 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 484
devices attached to the specified port. Some information varies with the switch model and port type. The following lines appear: Type PID WWN . Class of services supported. This can be a combination of the following bits: 4 Class of service includes class 2. 8 Class of service includes class 3. - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 485
Examples To display login information for port 23: switch:admin> portloginshow 23 Type PID world wide name credit df_sz cos fe 201700 21:00:00:e0:8b:05:a3: FFFC20 ff 201700 21:00:00:e0:8b:05:a3:c9 0 0 8 d_id=FFFFFC See also fcpProbeShow portShow Fabric OS 5.x command reference guide 485 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 486
debug_pdisc_flag. Operands This command has the following operand: lvl Specify either 0 to clear the flag or 1 to set the debug_pdisc_flag. Examples To set the debug_pdisc_flag: switch:admin> portlogpdisc 1 PDISC log setting = 1 See also none 486 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 487
log for that port is enabled. Operands none Examples To disable the information about the port log settings: switch:admin> portLogPortShow Port Disabled 0 1 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 10 0 11 0 12 0 13 0 14 0 15 0 (continued on next page) Fabric OS - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 488
16 0 17 0 18 1 19 0 20 0 21 0 22 0 23 0 24 0 25 0 26 0 27 0 28 0 29 0 30 0 31 0 See also portLogEventShow portLogReset portLogTypeDisable portLogTypeEnable 488 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 489
to enable the port log facility. See portLogClear for events that might disable the port log facility. Operands none Examples To enable the port log: switch:admin> portlogreset See also portLogPortShow Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 490
has the following operand: num_entries Specifies the number of entries to which portlog needs to be resized. The valid range of values is 8,192 to 16,384. Examples To resize the port log: switch:admin> portlogresize 12288 See also portLogConfigShow 490 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 491
each page of output. Port logs are circular log files in the switch firmware, which can save up to 8,192 entries. See portLogConfigShow to display in milliseconds. The clock resolution is 16 milliseconds. Displays the name of the internal switch procedure that logged the event, interrupt guide 491 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 492
unit header log from write operation err Information unit header log of an fc error frame frame fc frame payload nsRemQ Inter-switch name server query rscn RSCN xalloc Allocate an exchange xfree Free an exchange xerr Exchange error xstate Exchange state payload Frame payload - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 493
, if applicable (as specified in [A]). [B] The CT-based service command code ctout Argument 0 is also divided into two 16-bit fields: [A] A bit map indicating whether subsequent args are valid (0001 means argument 1 LR3 Link Reset: LRR Receive State Fabric OS 5.x command reference guide 493 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 494
E_Port loopback LIP as requested by the LINIT ELS received LIP as requested by the LPC ELS received Restart loop for QuickLoop looplet setup Restart information displayed by this command, see the HP StorageWorks Fabric OS 5.x procedures user guide. Operands This command has the followingoptional - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 495
Examples To view the port log for a port: switch:user> portLogShow 24 time task event port cmd args 17:05:30.384 PORT Rx 0 40 02fffffd,00fffffd 17:05:31.782 PORT Rx 3 0 c0fffffd,00fffffd,0e090908 See also portLogClear portLogDump upTime Fabric OS 5.x command reference guide 495 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 496
Operands This command has the following operand: portid Specify a nonzero value that specifies which port appears. Examples To display a port log for port 14: switch:user> portLogShowPort 14 time task event port cmd args 08:35:28.483 tFabric scn 14 0 08:35:27.899 tShell pstate 14 OL1 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 497
:35:28.483 tFabric ioctl 14 a1 0,0 08:35:28.483 tFabric scn 14 5 (output truncated) See also portLogClear portLogShow upTime Fabric OS 5.x command reference guide 497 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 498
be disabled. The values corresponding to different log types can be obtained by running portLogEventShow. Examples To disable event 2 from reporting to the port log: switch:admin> portlogtypedisable 2 See also portLogEventShow portLogTypeEnable 498 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 499
be enabled. The values corresponding to different log types can be obtained by running portLogEventShow. Examples To enable event 2 to report to the port log: switch:admin> portlogtypeenable 2 See also portLogEventShow portLogTypeDisable Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 500
number][-nframes count][-lb_mode mode] [-spd_mode mode][-ports itemlist] Availability admin Description Use this command to verify the functional operation of the switch by sending frames from the port N transmitter and looping them back into the same port N receiver. The loopback is done at the - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 501
1 Gb/s; set all odd ports' speed for 2 Gb/s. Specify a list of user ports to test. By default, all of the user ports in the current switch are tested. This option can be used to restrict testing to the specified ports. Examples To run a functional test of a connection - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 502
messages if failures are detected: DATA ERRSTAT INIT PORTDIED STATS TIMEOUT XMIT See the HP StorageWorks Fabric OS 5.x diagnostics and system error messages reference guide for more information. See also camTest centralMemoryTest cmemRetentionTest cmiTest crossPortTest itemList portRegTest spinSilk - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 503
present will be displayed. The port name is a string of 32 characters or fewer. It can consist of white spaces or name is a character string from 1 to 32 characters, including spaces and characters excluding commas, a port: switch:admin> portname 1/3, "Tape drive 8" switch:admin> portname 1/3 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 504
portCfgDefault portShow 504 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 505
on the switch. Data appears in 8 or 16 columns, one default is one second. This operand is optional. Examples To display port throughput for a switch: switch:user> portperfshow 20 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 272k 0 330 0 310m See also portStatsShow Fabric OS 5.x command reference guide 505 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 506
)and, repeat the write, read, and compare cycle. Shift again and repeat until the last writable bit in register N is reached (0x80000000 for a 32-bit register). For example, a 6-bit register is effectively tested with the following patterns: 0x0001 0x0010 0x0100 0x1000 0x0002 0x0020 0x0200 0x2000 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 507
Examples To run a bit write/read test of the ASIC SRAMs and registers: switch:admin> portregtest -ports 1/0-1/15 Running Port Register Test .... Test Complete: "portregtest" REGERR_UNRST See the HP StorageWorks Fabric OS 5.x diagnostics and system error messages reference guide for more information. - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 508
or set of looped devices) attached to the local switch • The format of ports_bitmap is the same as bit maps in the other tables; however, this table typically has only Bit 16 set (value 0x10000), indicating this port always routes broadcast frames to the embedded port, for handling by the firmware - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 509
Examples To display the routing tables for a port: switch:user> portrouteshow 4/15 port address ID: 0x02bf00 external unicast routing table: 1: 0x4 (vc=3) 2: 0x10000 (vc routing table: 0x10000 See also bcastShow fabricShow switchShow topologyShow uRouteShow Fabric OS 5.x command reference guide 509 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 510
as shown in Table 17. Information varies with the switch model and port type. Table 17 portShow display fields disabled, if it has not been disabled by portDisable or portCfgPersistentDisable. Port control flags. Bit map of port status flags, including information on the type of port, whether it - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 511
. port generation number Port generation number for the last offline state change. portId 24-bit port ID. portIfId User port's interface ID. portWwn Port WWN. portWwn of devices buffer available interrupts. Overrun Buffer overrun interrupts. Fabric OS 5.x command reference guide 511 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 512
Table 17 portShow display fields (continued) Field Description Suspended Parity_err 2_parity_err CMI_bus_err Transmission suspended interrupts. Central memory parity errors. Secondary Tx parity errors. Control message interface errors. The second column displays link error status block counters - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 513
the state of a port: switch:user> portshow 2/15 portName 16 E_Port Trunk port port generation number: 0 portId: 012f00 portIfId: 43320010 portWwn: 20:2f:00:60:69:e4:20 : 0 Fbsy: 0 See also authUtil portCfgLongDistance portLoginShow portName switchShow Fabric OS 5.x command reference guide 513 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 514
portStats64Show Displays the 64-bit hardware statistics for a port. Synopsis portstats64show [slotnumber/]portnumber Availability all users Description Use this command to display the following hardware statistics for a port. Two integers - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 515
switchShow to display a list of valid ports. Examples To display the 64-bit hardware statistics for a port: switch:user> portstats64show 4/15 stat64_wtx 0 top_int : 4-byte words transmitted : Encoding errors inside of frames (continued on next page) Fabric OS 5.x command reference guide 515 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 516
er64_crc 0 top_int : Frames with CRC errors 0 bottom_int : Frames with CRC errors er64_trunc 0 top_int : Frames shorter than minimum 0 bottom_int : Frames shorter than minimum er64_toolong 0 top_int : Frames longer than maximum 0 bottom_int : Frames longer than maximum er_bad_eof 0 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 517
statistics of a specified switch port. Synopsis portstatsclear to-end monitor, and filter-based monitor statistics, for a specified switch port. For platforms with a Bloom-based ASIC, the command also port: switch:admin> portstatsclear 4/15 See also portStats64Show Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 518
Some counters are platform- and port-specific and appear only with those platforms and ports. All statistics have a maximum 32-bit value of 4,294,967,295. stat_wtx stat_wrx stat_ftx stat_frx stat_c2_frx stat_c3_frx stat_lc_rx stat_mc_rx stat_mc_to stat_mc_tx tim_rdy_pri tim_txcrd_z er_enc_in er_crc - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 519
for a port: switch:user> portstatsshow 32 Class 3 frames received stat_lc_rx 0 Link control frames received stat_mc_rx 0 Multicast frames received stat_mc_to 0 Multicast timeouts stat_mc_tx 0 Multicast frames transmitted (continued on next page) Fabric OS 5.x command reference guide - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 520
0 Frames longer than maximum 0 Frames with bad end-of-frame 8600353 Encoding error outside of frames 0 Class 3 frames discarded 16 loop_open 16 loop_transfer 16 FL_Port opened 0 tenancies stopped due to starvation 3277 number of times FL has the tenancy 11 number of times NL has - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 521
, followed by a slash (/). Specify a port number to be configured, relative to its slot for bladed systems. Examples To swaps area numbers between a pair of ports: switch:admin> portswap 1/e 2/5 portswap done Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 522
See also portDisable portEnable portShow portSwapDisable portSwapEnable portSwapShow switchShow 522 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 523
: Enabling or disabling the portswap feature does not effect previously performed portswap operations. Operands none Examples To disable the portswap feature: switch:admin> portswapdisable See also portDisable portEnable portShow portSwapEnable portSwapShow switchShow Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 524
. NOTE: Enabling or disabling the portswap feature does not effect previously performed portswap operations. Operands none Examples To enable the portswap feature: switch:admin> portswapenable See also portDisable portEnable portShow portSwapDisable portSwapShow switchShow 524 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 525
. The default area number of a port is the same as its switch port number. Operands none Examples To display the state of the portswap feature and information for ports whose area numbers have been swapped: switch:admin> portswapshow PortSwap is enabled Slot Slotport Swport Area 2 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 526
problems to near-end terminal equipment, far-end terminal equipment, or the transmission line. Diagnostics can be executed every day or on demand. This command verifies the intended functional operation of the switch port types are supported: • E_Ports • F_Ports (must support ELS ECHO) • L_Ports - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 527
test. By default, all the user ports in the switch are tested. See the itemList help pages for further to execute this test. The default value is 20. Valid values include: 0 Run the test the types of patterns that are supported with portTest. dataTypeShow displays the an active switch: switch:admin> - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 528
portTestShow Displays information from portTest. Synopsis porttestshow [-ports itemlist] Availability admin Description Use this command to display a snapshot of information from portTest. The following information appears: • Pass or fail information on a given port • Port type tested • Current - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 529
Examples To display information from portTest: switch:admin> porttestshow 1 Port 1 : PASS PortType: OTHER PortState: NO TEST PortInternalState: : 0 See also crossPortTest fportTest itemList loopPortTest portLoopbackTest portTest spinFab stopPortTest Fabric OS 5.x command reference guide 529 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 530
order. Whenever a power supply goes out of service or a field-replaceable unit (FRU) is inserted the CP boards' processors to cease execution of the firmware. In this situation, all operation of the system terminates switch model and the number of slots present. Operands none 530 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 531
Examples To modify the power-off list order: switch:admin> powerofflistSet Slot Current POL 10 1st 9 2nd 8 3rd 7 4th 4 5th 3 6th 2 8th Proceed to change the POL order? (yes, y, no, n): [no] y See also chassisShow powerOffListShow psShow Fabric OS 5.x command reference guide 531 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 532
slotPowerOff slotPowerOn slotShow 532 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 533
lack of power causes the CP boards' processors to cease execution of the firmware. In this situation, all operation of the system terminates immediately. However, if varies, depending on the switch model and the number of slots present. Operands none Examples To display the command reference guide 533 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 534
See also chassisShow powerOffListShow psShow slotPowerOff slotPowerOn slotShow 534 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 535
display the current status of the switch power supplies. The status of each the status of the power supply for an HP StorageWorks Core Switch 2/64: switch:admin> psShow Power Supply #1 is OK DELTA the power supply for an HP StorageWorks SAN Switch 2/32 switch: switch:admin> psShow Power Supply #1 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 536
See also chassisShow fanShow 536 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 537
HP Advanced Zoning license, which is included within the Base Configuration Services and bundled with each B-series switch switch. Use this command only with Fabric OS 3.x systems in the fabric; QuickLoop is not supported second WWN to "qlp1": switch:admin> qloopAdd "qlp1", "wwn2" See also - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 538
requires HP Advanced Zoning license, which is included within the Base Configuration Services and bundled with each B-series switch. Description only from the primary FCS switch. Use this command only with Fabric OS 3.x systems in the fabric; QuickLoop is not supported in Fabric OS 5.x. Operands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 539
Examples To create two QuickLoops, a single switch and one dual switch: switch:admin> qloopCreate "qlp1", "10:00:00:60:69:00:60:11" switch:admin> qloopCreate "qlp2", "wwn2; wwn3" See also qloopAdd qloopDelete qloopRemove qloopShow Fabric OS 5.x command reference guide 539 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 540
requires HP Advanced Zoning license, which is included within the Base Configuration Services and bundled with each B-series switch. Description only from the primary FCS switch. Use this command only with Fabric OS 3.x systems in the fabric; QuickLoop is not supported in Fabric OS 5.x. Operands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 541
requires HP Advanced Zoning license, which is included within the Base Configuration Services and bundled with each B-series switch. Description only from the primary FCS switch. Use this command only with Fabric OS 3.x systems in the fabric; QuickLoop is not supported in Fabric OS 5.x. Operands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 542
See also qloopAdd qloopCreate qloopDelete qloopShow 542 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 543
HP Advanced Zoning license, which is included within the Base Configuration Services and bundled with each B-series switch. from the primary FCS switch. Use this command only with Fabric OS 3.x systems in the fabric; QuickLoop is not supported in Fabric OS 5.x. OS 5.x command reference guide 543 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 544
Examples To display all QuickLoops beginning with the letter "q": switch:admin> qloopshow "q*" qloop: qlp1 qloop: qlp2 10:00:00:60:69:00:60:11 10:00:00:60:69:00:30:02 10:00:00:60:69:00:60:13 See also qloopAdd qloopCreate qloopDelete qloopRemove 544 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 545
the output displayed on the switch console (telnet session only). By default, quiet mode is off and all switch tasks can send output to then set it to off: switch:admin> quietMode quietMode: On Usage: quietMode 0|1 0: to turn it off 1: to turn it on switch:admin> quietMode 0 Committing - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 546
rcsDisabled Displays whether Reliable Commit Service (RCS) is enabled. Synopsis rcsdisabled Availability all users on Fabric OS v4.1.x, and above, and v5.x FCS switch in the fabric. Operands none Examples To display the RCS status: switch:admin> rcsDisabled rcsDisabled = 0 See also none 546 Fabric - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 547
CP in a director or an entire switch. The command line session is closed. When this command is issued on a single-CP system, all switches in the system switch is part of a fabric, reboot the switch so that the remaining switchesare reconfigured. Operands none Examples To reboot the CP: switch:admin - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 548
to display a list of FSPF-related commands. Operands none Examples To display a list of FSPF-related commands: switch:admin> routehelp aptPolicy bcastShow dlsReset dlsSet dlsShow fspfShow interfaceShow iodReset iodSet iodShow linkCost LSDbShow nbrStateShow nbrStatsClear topologyShow uRouteConfig - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 549
Removes all the core files under the listed directories. The directory list is a comma-separated list of core files directory and other files, if any, will be ignored. No confirmation will be made before removal. Specify this option to list all core files. Fabric OS 5.x command reference guide 549 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 550
Examples To list all core files in a CP: switch:admin> savecore -l /core_files/panic/core.873 /core_files/zoned/core.1234 /core_files/zoned/core.5678 /mnt/core_files/nsd/core.873 /mnt/core_files/panic/core.873 To remove selected core files from a CP: switch:admin> savecore -r /core_files/panic/,/ - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 551
action 9(or e): Exit Your choice: 1 /mnt/core_files/panic You have opted to remove ALL core files:Please confirm (Y/[N]): y Removing files.... removing core files under: /mnt/core_files/panic Done! switch:admin> switch:admin> savecore No core files found! Fabric OS 5.x command reference guide 551 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 552
files using the savecore management utility: switch:admin> savecore following 1 directories contains core files: [ ]0: /core_files/zoned Welcome to core files management utility. Menu 1(or R): Remove all core files 2(or F): FTP all core files 3(or r): Remove marked files 4(or f): FTP marked files - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 553
To remove core files from a selected directory: switch:admin> savecore following 2 directories contains core files: [ ]0: /core_files/nsd [ ]1: /core_files/zoned Welcome to core files management utility. Menu 1(or R): Remove all core files 2(or F): FTP all core files 3(or r): Remove marked files 4( - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 554
See also none 554 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 555
staff. The information displayed might not be supported between releases and is subject to change arbitrarily. NOTE: This command must be issued in secure mode. Operands none Examples To display the size of the active security database: switch:admin> secactivesize Size of security active data - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 556
, when the command is completed new data is saved persistently. New data is effective with the next authentication request. The configuration applies to a switch instance only. NOTE: A security license is required to run this command in nonsecure as well as secure mode. Operands The operands are as - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 557
switch is configured to do DH-CHAP, it is performed whenever a port or a switch is setting up shared secrets > Enter WWN, Domain, or switch name (Leave blank when done): 10:00:00:60: enter local secret: Enter WWN, Domain, or switch name (Leave blank when done): Are you done? (yes, y, - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 558
blank when done): Are you done? (yes, y, no, n): [no] y Saving data to key store... Done. To delete the entire secret key database: switch:admin> secAuthSecret --remove --all This command deletes database of DH-CHAP secret keys. If a fabric requires authentication, deleting this database may cause - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 559
Generate a certificate signing request (CSR). • Delete a CSR. • List the certificates present in the switch. • Display the contents of a certificate/CSR. • Delete a specific certificate. • Configure a SSL show filename Display certificate content Fabric OS 5.x command reference guide 559 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 560
third-party certificates. The key length can be either 1,024 or 2,048 bits long. The greater the length of the key, the more secure is the cacert] | [-config swcert [-enable https]] Import a certificate on to the switch. Use this for the following: • Download a certificate issued by a CA after - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 561
[certificate file name]. To import a certificate with configure and enable option: switch:admin> seccertutil import -config swcert -enable https Select protocol [ftp or scp has been enabled. To display contents of a CSR: switch:admin> seccertutil showcsr Fabric OS 5.x command reference guide 561 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 562
To display contents of a certificate: switch:admin> seccertutil show certificate file name See also none 562 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 563
staff. The information displayed might not be supported between releases and is subject to change arbitrarily. NOTE: This command must be issued in secure mode. Operands none Examples To display the size of the defined security database: switch:admin> secdefinesize Size of security defined data - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 564
.100.148 "nonfcs" Backup 10:00:00:60:69:00:12:53 2 Ready 192.168.100.147 "backup" Primary 10:00:00:60:69:22:32:83 3 Ready 192.168.100.135 "switch" Secured switches in the fabric: 3 564 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 565
See also secPolicyDump secPolicyShow Fabric OS 5.x command reference guide 565 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 566
serial connections. Operands none Examples To enable a backup FCS switch to take over as the primary FCS switch: switch:admin> secfcsfailover This switch is about to become the Primary FCS switch. All transactions of the current Primary FCS switch will be aborted. ARE YOU SURE (yes, y, no, n): [no - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 567
not be supported between releases and is subject to change arbitrarily. NOTE: This command must be issued when secure mode is enabled. Operands none Examples To view the current security state: switch:admin> secglobalshow See also secActiveSize secDefineSize Fabric OS 5.x command reference guide 567 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 568
secHelp Displays information about security commands. Synopsis sechelp Availability all users Description Use this command to display a list of security commands. Operands none 568 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 569
switch Forces primary role to this FCS switch Displays current internal security state information disabled Sets the admin passwd for non-FCS switches Aborts changes to defined policy Activates all policy Saves defined policy set and sends to all switches Shows members of one or more policies - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 570
both the defined and active security database. This command can be issued only in secure mode and only from the primary FCS switch. Operands none Examples To disable security mode: primaryfcs:admin> secmodedisable Please enter current admin account password: Warning!!! About to disable security. ARE - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 571
switches in the fabric. This command fails if any switch switches. • Resetting the admin and user account passwords on all non-FCS switches. • Disabling the root and factory accounts on all non-FCS switches FCS switches is switches are present in the fabric, the command can be issued on any switch - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 572
fabric before enabling secure mode; otherwise, users on non-FCS switches lose their telnet sessions. HP recommends that a maximum of 80 WWNs be specified in or switch name format, as follows: "5; 10:00:00:60:69:00:00:20; star1" If a member is specified by domain or switch name, the switch must - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 573
with all switches being FCS, all switches having passwords the switch specified as the primary FCS switch. If no operand enter FCS switch members and Switch Certificate, Security license and Zoning license to be installed on every switch may be closed and some switches may go through a reboot - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 574
form a secure fabric. This is an interactive session to create a FCS list. The new FCS list is empty. Enter WWN, Domain, or switch name(Leave blank when done): 102 Switch WWN is 10:00:00:60:69:80:04:0f. The new FCS list: 10:00:00:60:69:80:04:0f - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 575
Warning: Access to the Root and Factory accounts may be required for proper support of the switch. Please ensure the Root and Factory passwords are documented in a secure location for root New FCS switch root password: Re-type new password: (output truncated) Fabric OS 5.x command reference guide 575 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 576
not use these security features. Do you agree to these terms? (yes, y, no, n): [no] y This command requires Switch Certificate, Security license and Zoning license to be installed on every switch in the fabric. PLEASE NOTE: On successful completion of this command, login sessions may be closed and - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 577
switch. DID Displays the domain of the FCS switch. swName Displays the alias name of the FCS switch. This command can be issued on any switch current security mode of a fabric: switch:admin> secmodeshow Secure Mode: ENABLED. Version Stamp: 9182, Wed Mar 17 16:37:01 2004. POS Primary WWN - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 578
long and can consist of any combination of alphanumeric characters. This command can be issued only in secure mode and only from the primary FCS switch. NOTE: Ensure no non-FCS admin users are logged in when this command is executed; otherwise, users on non-FCS - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 579
NOTE: This command can be issued only in secure mode and only from the primary FCS switch. Operands none Examples To abort all changes that have not been saved to flash memory: primaryfcs secPolicyDump secPolicyRemove secPolicySave secStatsShow Fabric OS 5.x command reference guide 579 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 580
in the fabric. Synopsis secpolicyactivate Availability admin Description Use this command to activate the current defined security policy to all switches in the fabric. After activation, the defined policy set becomes the active policy set. NOTE: This command can be issued only in secure mode - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 581
that management access method (the DCC_POLICY is an exception). NOTE: This command can be issued only in secure mode and only from the primary FCS switch. Fabric OS 5.x command reference guide 581 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 582
API_POLICY RSNMP_POLICY WSNMP_POLICY SES_POLICY (HP does not support SES_POLICY) MS_POLICY SERIAL_POLICY FRONTPANEL_POLICY policy names, but they are case sensitive. member Specify a list of member switches for the security policy. The members must be enclosed in quotation marks and separated - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 583
HP does not support SES_POLICY) • MS_POLICY • SERIAL_POLICY • FRONTPANEL_POLICY • SCC_POLICY These policy types require members be specified as WWN strings, domain IDs, or switch names. If domain ID, or switch names are used, the switches ports on the switch. [3, 9] the switch and WWN: switch:admin> - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 584
is 11:22:33:44:55:66:77:aa and port WWN of the second device is 11:22:33:44:55:66:77:bb: switch:admin> secpolicyadd "DCC_POLICY_abc", "11:22:33:44:55:66:77:aa;11:22:33:44:55:66:77:bb;3(1,3)" Member(s) have been added to DCC_POLICY_abc - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 585
the current sectelnet or serial session and a warning is issued. This command can be issued only in secure mode and only from the primary FCS switch. Fabric OS 5.x command reference guide 585 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 586
• API_POLICY • RSNMP_POLICY • WSNMP_POLICY • SES_POLICY (HP does not support SES_POLICY) • MS_POLICY • SERIAL_POLICY • FRONTPANEL_POLICY • type, members can be specified using IP address, WWN, domain, or switch name. IP Address Member Policy Types The following policy types require members be - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 587
HP does not support SES_POLICY) MS_POLICY SERIAL_POLICY FRONTPANEL_POLICY These policy types require member IDs be specified as WWN strings, domains, or switch names. If domain, or switch names are used, the switches [*] Selects all ports on the switch and devices currently attached to those - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 588
:77:aa and the WWN of second device is 11:22:33:44:55:66:77:bb): switch:admin> secpolicycreate "DCC_POLICY_aB_7", "11:22:33:44:55:66:77:aa;11:22:33:44:55 192.168.5.0/24 network to access the fabric through sectelnet: switch:admin> secpolicycreate "TELNET_POLICY", "192.168.5.0" TELNET_POLICY has been - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 589
. If the policy is deleted all access is granted. NOTE: This command can be issued only in secure mode and only from the primary FCS switch. Fabric OS 5.x command reference guide 589 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 590
RSNMP_POLICY WSNMP_POLICY SES_POLICY (HP does not support SES_POLICY) MS_POLICY SERIAL_POLICY FRONTPANEL_POLICY policy is deleted, fabric-wide switch access through that method is unrestricted. Examples To delete an existing security policy: switch:admin> secpolicydelete "MS_POLICY" About - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 591
secPolicyRemove secPolicySave secStatsShow Fabric OS 5.x command reference guide 591 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 592
command can be issued only in secure mode but from any primary FCS switch. Operands This command has the following operands: listtype name Specify which database • RSNMP_POLICY • WSNMP_POLICY • SES_POLICY (HP does not support SES_POLICY) • MS_POLICY • SERIAL_POLICY • FRONTPANEL_POLICY - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 593
DEFINED POLICY SET TELNET_POLICY IpAddr 192.155.52.13 192.155.52.11 ACTIVE POLICY SET TELNET_POLICY IpAddr 192.155.52.0 Fabric OS 5.x command reference guide 593 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 594
See also secPolicyAbort secPolicyActivate secPolicyAdd secPolicyCreate secPolicyDelete secPolicyRemove secPolicySave secStatsShow 594 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 595
FCS can be moved at a time. The first FCS switch in the list that is also present in the fabric only from secure mode and only from the primary FCS switch. If a backup FCS is moved to the first position FCS switch you want to move. Specify the position to which you want to move the FCS switch. If - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 596
Examples To move the backup FCS switch at position 2 to position 3 in the FCS list: switch:admin> secpolicyfcsmove Pos Primary WWN DId swName. 1 Yes 10:00:00:60:69:10:02:18 1 switch5. 2 No 10:00:00:60:69:00:00: - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 597
command can be issued only from secure mode and only from the primary FCS switch.. Operands This command has the following operands: name Specify the name of an WSNMP_POLICY SES_POLICY (HP does not support SES_POLICY) MS_POLICY SERIAL_POLICY Fabric OS 5.x command reference guide 597 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 598
, members can be specified using IP address, WWN, domain, or switch name. IP address member policy types The following policy types require members specified by WWN address: • FCS_POLICY • SES_POLICY (HP does not support SES_POLICY) • MS_POLICY • SERIAL_POLICY • FRONTPANEL_POLICY • SCC_POLICY - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 599
is the only option. Examples To remove a member that has a WWN of 12:24:45:10:0a:67:00:40 from MS policy: switch:admin> secpolicyremove "MS_POLICY", "12:24:45:10:0a:67:00:40" Member(s) have been removed from MS_POLICY. See also secPolicyAbort secPolicyActivate secPolicyAdd secPolicyCreate - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 600
can be issued only from secure mode and only from the primary FCS switch. Operands none Examples To save new policy set in all switches in the fabric: switch:admin> secpolicysave secpolicysave command was completed successfully. See also secPolicyAbort secPolicyActivate secPolicyAdd secPolicyCreate - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 601
database without page breaks. NOTE: This command can be executed on any FCS switch in fabric. Operands This command has the following operands: listtype name Specify which • RSNMP_POLICY • WSNMP_POLICY • SES_POLICY (HP does not support SES_POLICY) • MS_POLICY • SERIAL_POLICY • - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 602
Yes 10:00:00:60:69:30:15:5c 1 primaryfcs HTTP_POLICY IpAddr 192.155.52.0 To display all security policies from defined databases: switch:admin> secpolicyshow "defined DEFINED POLICY SET FCS_POLICY Pos Primary WWN DId swName 1 Yes 10:00:00:60:69:30:15:5c 1 primaryfcs HTTP_POLICY - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 603
0. Synopsis secstatsreset ["name"][,"list"] Availability admin Description Use this command to reset one or all security statistics to 0. This command can be issued to any switch. If issued on the primary FCS switch, this command can reset security statistics for any or all - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 604
API_POLICY • RSNMP_POLICY • WSNMP_POLICY • SES_POLICY (HP does not support SES_POLICY) • MS_POLICY • SERIAL_POLICY • FRONTPANEL_POLICY which to reset the security statistics. Specify an asterisk (*) to represent all switches in the fabric or specify a list of domains, separated by semicolons. - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 605
to reset all security counters. Are you sure (yes, y, no, n):[no] y Security statistics reset to zero. To reset DCC_POLICY statistics on domains 1 and 69: switch:admin> secstatsreset "DCC_POLICY", "1;69" Reset DCC_POLICY statistic. See also secFabricShow secStatsShow Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 606
to display one or all security statistics. This command can be issued to any switch. If issued on the primary FCS switch, this command can retrieve and display the security statistics for any or all switches in the fabric. NOTE: This command displays security policy statistics in secure mode. In - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 607
API_POLICY • RSNMP_POLICY • WSNMP_POLICY • SES_POLICY (HP does not support SES_POLICY) • MS_POLICY • SERIAL_POLICY • FRONTPANEL_POLICY display the security statistics on. Specify an asterisk (*) to represent all switches in the fabric or specify a list of domains separated by semicolons. This - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 608
the MS_POLICY statistics on the local switch: switch:admin> secstatsshow "MS_POLICY" Name Value MS 20 To display statistic information for TELNET_POLICY for all switches in the fabric (example from a nonsecure switch): switch:admin> secstatsshow "TELNET_POLICY", "*" Fabric Statistics - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 609
operands: domain login_name Specify the domain of the switch from which the temporary passwords are to be removed. This operand is optional. Specify the name of the login account from which the temporary password are removed. This operand is optional. Fabric OS 5.x command reference guide 609 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 610
2 Temporary password of each account on domain 2 has been successfully reset (if switch is non fcs switch it will further display). Root and factory accounts on domain 2 have been disabled. switch:admin> sectemppasswdreset All temporary passwords or account settings have been restored to fabric-wide - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 611
> sectemppasswdset 2, "root" Please provide password of root on primary FCS switch in order to change this password: ******** Set remote switch root password: ******** Re-enter new password: ******** Account root has been successfully enabled on domain 2 Fabric OS 5.x command reference guide 611 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 612
See also passwd secModeDisable secModeShow secNonFcsPasswd secTempPasswdReset 612 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 613
from management application problems. This command aborts switch:admin> sectransabort Transaction has been aborted. See also secPolicyAbort secPolicyActivate secPolicyAdd secPolicyCreate secPolicyDelete secPolicyDump secPolicyRemove secPolicySave secStatsShow Fabric OS 5.x command reference guide - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 614
Description Use this command to reset the security version stamp of all switches in a fabric to 0, so that it can be joined to Cascade the fabrics together. When the secure fabrics merge, the primary FCS switch in the controller fabric propagates its security policies across the newly formed fabric - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 615
from sensors located on the switch. The actual location of the sensors varies, depending on the switch type. Operands none Examples To view the sensor values: switch:admin> sensorshow sensor 1: (Temperature Supply ) is Absent See also fanShow tempShow Fabric OS 5.x command reference guide 615 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 616
omitted, this command displays the current debug and verbose level of the specified module. Examples To set debug level of module named NS to value 3: switch:admin> setdbg NS 3 switch:admin> dbgshow NS Module NS, debug level = 3, verbose level = 0 See also dbgShow 616 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 617
to display the current mode setting. This operand is optional. If no operand is specified, the current value displays. Examples To display the ESD mode: switch:admin> setesdmode -show Esd Mode is 0 (Disabled). See also spinSilk Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 618
operand is optional. Examples To enable, disable, and then display the media mode: switch:admin> setgbicmode 1 GBIC mode is now 1 (Enabled). switch:admin> setsfpmode 0 SFP mode is now 0 (disabled). switch:admin> setmediamode -show Media mode is now 0 (disabled). See also crossPortTest itemList - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 619
operand is optional. Examples To enable, disable, and then display the media mode: switch:admin> setgbicmode 1 GBIC mode is now 1 (Enabled). switch:admin> setsfpmode 0 SFP mode is now 0 (disabled). switch:admin> setmediamode -show Media mode is now 0 (disabled). See also crossPortTest itemList - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 620
control processor (CP). Synopsis setmodem [-e] | [-d] Availability admin Description Use this command to enable or disable modem dial-in to a CP on those systems that support modem dial-in. When modem dial-in is enabled, you can log in to a CP through a modem, and a modem attached to the CP accepts - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 621
manual for your platform for complete modem installation instructions. RJ-11 "Y" Adapter Optional Handset DB-25M to DB-9F Modem Cable (one per CP Card) Modem Port on CP Card (one per CP Card; RS-232 d 2 c 1 b 0 a ! ! RS - 232 RS - 232 IOIOI IOIOI Link 10/100 Mb/s Active CP Link 10/100 switch - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 622
operand is optional. Examples To enable, disable, and then display the media mode: switch:admin> setgbicmode 1 GBIC mode is now 1 (Enabled). switch:admin> setsfpmode 0 SFP mode is now 0 (disabled). switch:admin> setmediamode -show Media mode is now 0 (disabled). See also crossPortTest itemList - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 623
for M->M connected ports. This might be useful to isolate internal switch problems from SFP problems since the internal paths are used much less with SPLB mode Examples To enable or disable a two-port loopback: switch:admin> setsplbmode -show Splb Mode is 0 (Disabled) See also spinSilk Fabric - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 624
to be set; module names are case sensitive. Specify the verbose level (0 to 9). Examples To set the verbose level of a module named NS to value 3: switch:admin> setverbose NS 3 switch:admin> dbgshow NS Module NS, debug level = 0, verbose level = 3 See also dbgShow 624 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 625
the HP StorageWorks Core Switch 2/64, and the SAN Director 2/128 and 4/256, if there is a lot of activity on the switch, poll for all available SFPs. For Finisar smart SFPs, five additional fields appear: module in the switch. Displays detailed data for all available SFPs on the switch. This operand - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 626
Examples To display SFP summary information: switch:user> sfpshow Area 0: id (id) Vendor: Serial No: Area 1: -Area 9: -Area 10: -Area 11: -Area 12: -Area 13: -Area 14: -Area 15: -Area 16: id (sw) Vendor: AGILENT (output truncated) Serial No: H1149T2 Serial No: H112TUD Serial No: H11QET9 Serial No: - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 627
To display detailed SFP information for a Finisar smart SFP: switch:user> sfpshow 1/3 Identifier: 3 SFP Connector: 7 LC Transceiver: 050c402000000000 100,200_MB/s M5,M6 sw Inter_dist Encoding: 1 .8 mVolts RX Power: 199.6 uWatts TX Power: 235.2 uWatts Fabric OS 5.x command reference guide 627 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 628
To display all SPF information: switch:user> sfpshow -all Port 0: Identifier: 3 SFP Connector: 7 LC Transceiver: 050c402000000000 100,200_MB/s M5,M6 sw Inter_dist Encoding: 1 8B10B Baud Rate: 21 (units 100 megabaud) Length - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 629
standby CP is required for this command to take effect. No action is required on the active CP. Operands none Examples To disable flow control: switch:admin> shellflowcontroldisable Disabling flowcontrol flow control is now disabled See also shellFlowControlEnable Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 630
required on the active CP. CAUTION: If flow control is enabled and if the console output is suspended for an extended period of time, the switch might reboot. HP recommends disabling the flow control, using shellFlowControlDisable. Operands none Examples To enable flow control - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 631
command has the following operand: slotnumber Specify the slot number of the blade to disable. This operand is required. Examples To power off blade unit 3: switch:admin> slotoff 3 Slot 3 is being disabled. See also bladeDisable slotOn slotShow Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 632
command has the following operand: slotnumber Specify the slot number of the blade to enable. This operand is required. Examples To power on blade unit 3: switch:admin> sloton 3 Slot 3 is being enabled. See also slotOff slotShow 632 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 633
has the following operand: slotnumber Specify the slot number of the blade to disable. This operand is required. Examples To power off blade unit 3: switch:admin> slotpoweroff 3 Slot 3 is being powered off See also powerOffListSet powerOffListShow slotPowerOn slotShow Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 634
command has the following operand: slotnumber Specify the slot number of the blade to enable. This operand is required. Examples To power on blade unit 3: switch:admin> slotpoweron 3 Powering on slot 3. See also slotOn slotPowerOff slotShow 634 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 635
Slot Blade Type Displays the physical slot number. Displays the blade type: • SW BLADE-The blade is a switch. • CP BLADE-The blade is a control processor. ID Status • UNKNOWN-Blade not present or its type its state cannot be determined. Operands none Fabric OS 5.x command reference guide 635 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 636
Examples To display a blade inventory and status: switch:admin> slotshow Slot Blade Type ID Status 1 SW BLADE 2 FAULTY 2 SW BLADE 2 DISABLED 3 SW BLADE 2 ENABLED 4 SW BLADE 2 DIAG RUNNING POST2 5 CP BLADE 1 ENABLED (User - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 637
duration count ] Availability admin Description Use this command to verify the intended functional operation of the switch by sending SERDES BIST patterns from port N's transmitter, and looping the patterns back into the this test. The default value is 1. Fabric OS 5.x command reference guide 637 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 638
the specified slot (--slot) is used. See itemList for further details. Examples To test the serial link of the following port path: switch:admin> sltest -ports 0/5-0/31 -speed 4 -lb_mode 1 passcnt 1 Running Port sltest .... passed. Diagnostic When it detects failures, the test might report one or - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 639
the SNMP agent associated with the current switch. SNMPv1 configuration parameters There are six communities, respective trap recipients, and trap recipient severity levels supported by the agent. The first three the SNMP traps, and event traps (swEventTrap, Fabric OS 5.x command reference guide 639 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 640
entries of role snmpuser are supported. Separate default passwords are provided be in range of 2 to 32 characters. Note that the default switches individually. Unlike community strings, the user name and passwords are not distributed for other switches in range of 1 to 20 characters. Note that in order - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 641
octets. For example, an ACL of 192.168.64.0 enables access by any host that starts with can receive SW-TRAPS from the switch. The default value is yes. Users receive FA-TRAPS from the switch. The default value is receive FICON traps from the switch. The default value is from the switch. The default - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 642
authTraps System description. The default value is Fibre Channel Switch. Location of the system (switch). The default value is End User Premise. Contact information for this system (switch). The default value is set as Field Support. See the definition of sysDescr, sysLocation, and sysContact in - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 643
Examples To change the SNMPv1 configuration: switch:admin> snmpconfig --set snmpv1 SNMP community and trap recipient configuration: Community (rw): [Secret C0de] admin Trap Recipient's IP address in dot notation: [0.0.0.0] 10.32.225.1 Trap recipient Severity level : (0..5) [0] 1 Community (rw): [ - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 644
To change the SNMPv3 configuration: switch:admin> snmpconfig --set snmpv3 SNMPv3 user configuration: User (rw): [snmpadmin1] adminuser Auth Protocol [MD5(1)/SHA(2)/noAuth(3)]: (1..3) [3] 1 New Auth Passwd: Verify Auth Passwd: Priv Protocol [DES(1)/ - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 645
switch:admin> snmpconfig --set accessControl SNMP access list configuration: Access host subnet area in dot notation: [0.0.0.0] 192.168.0.0 Read/Write? (true, t, false, f): [true] Access host subnet area in dot notation: [0.0.0.0] 10.32 YES fruHistoryTrap: NO Fabric OS 5.x command reference guide 645 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 646
command will reset the agent's system group configuration back to factory default ***** sysDescr = Fibre Channel Switch sysLocation = End User Premise sysContact = Field Support authTraps = 0 (OFF) ***** Are you sure? (yes, y, no, n): [no] y See also agtCfgDefault agtCfgSet agtCfgShow snmpMibCapSet - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 647
switch. The default value is yes. Specifying switch. The default value is yes. Specifying yes means the SNMP management application can receive SW-EXTTRAPS from the switch . The default value is yes. Specifying yes means the SNMP management application can receive HA-TRAPS from the switch - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 648
Example To view or modify the options for configuring SNMP MIB traps: switch:admin> snmpmibcapset The SNMP Mib/Trap Capability has been set to support FE-MIB SW-MIB FA-MIB FICON-MIB HA-MIB SW-TRAP swFCPortScn swFabricWatchTrap FA-TRAP connUnitStatusChange connUnitSensorStatusChange HA-TRAP - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 649
all users Description Use this command to display the SNMP MIBs and traps capability of the SNMP agent in the switch. FA-MIB FICON-MIB HA-MIB SW-TRAP FA-TRAP SW-EXTTRAP FICON-TRAP HA-TRAP Specifying yes means to turn on or off these MIBs. Operands none Fabric OS 5.x command reference guide 649 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 650
Examples To display the options for configuring SNMP MIB trap capability: switch:admin> snmpmibcapshow FE-MIB: YES SW-MIB: YES FA-MIB: YES FICON-MIB: NO HA-MIB: YES SW-TRAP: YES swFCPortScn: YES swEventTrap: NO swFabricWatchTrap: - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 651
the ISL links between switches. At the maximum switch might be verified, as can be the groups present. The switch remains in normal switch and media. If these pass, the fault lies in the cable or remote switch switches that support trunking, then it is likely that trunk groups are - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 652
, all of the ISL ports in the current switch will be tested. See itemList help pages for further details. Instruct spinFab how to mark failed ports. If set disabled by default. Specify a remote domain to which the switch is connected. The default is to automatically determine the remote domain - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 653
PORT_M2M PORT_STOPPED PORT_WRONG RXQ_RAM_PERR STATS STATS_C3FRX STATS_FRX STATS_FTX TIMEOUT XMIT See the HP StorageWorks Fabric OS 5.x diagnostics and system error messages reference guide for more information. See also camTest centralMemoryTest cmemRetentionTest cmiTest crossPortTest itemList - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 654
spinJitter Measures line-speed jitter. Synopsis spinjitter [--slot number] [-nmegs count] [-lb_mode mode] [-spd_mode mode] [-ports itemlist] Availability admin Description This test uses the same procedures as spinSilk but with a special pattern for line-speed jitter measurement. The test uses - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 655
used. See itemList for further details. Examples To measure line-speed jitter: switch:admin> spinjitter -ports 1/0 - 1/2 Running SpinJitter One moment please ...Ports 1 id 2G Online Testing ...... 2 1 2 id 2G Online Testing ...... (output truncated) Fabric OS 5.x command reference guide 655 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 656
NO_SEGMENT PORT_ABSENT PORT_DIED PORT_ENABLE PORT_M2M PORT_STOPPED PORT_WRONG RXQ_FRAME_ERR RXQ_RAM_PERR STATS STATS_C3FRX STATS_FRX STATS_FTX TIMEOUT XMIT See the HP StorageWorks Fabric OS 5.x diagnostics and system error messages reference guide for more information. 656 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 657
See also backport camTest centralMemoryTest cmemRetentionTest cmiTest crossPortTest itemList portLoopbackTest portRegTest spinSilk sramRetentionTest Fabric OS 5.x command reference guide 657 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 658
this command to verify the intended functional operation of the switch, at the selected speed, by configuring the routing hardware 0-8, and so forth), and mirrored on the port on the next blade, where applicable (0-16, 0-32, and so forth). An error is reported if there are missing plugs. If you want - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 659
• 128 bytes of RANDOM • 512 bytes of the results of portLoopbackTest, can be used to determine which components of the switch are faulty. Operands This command has the following operands:- -nmegs count -lb_mode loopback 4 Internal (parallel) loopback Fabric OS 5.x command reference guide 659 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 660
. This mode should be used for debugging purposes. Specify a list of user ports to test. By default, all of the user ports in the current switch are tested. This option might be used to restrict testing to the specified ports. 660 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 661
-ports 1/0 - 1/2 Running Spin Silk One moment please ...Ports Segmented (0) switchName: switch switchType: 10.1 switchState: Offline switchRole: Disabled switchDomain: 1 (unconfirmed) switchId: fffc01 switchWwn ERR_STAT_ENCIN ERR_STAT_ENCOUT Fabric OS 5.x command reference guide 661 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 662
PORT_STOPPED PORT_WRONG RXQ_FRAME_ERR RXQ_RAM_PERR STATS STATS_C3FRX STATS_FRX STATS_FTX TIMEOUT XMIT See the HP StorageWorks Fabric OS 5.x diagnostics and system error messages reference guide for more information. See also backport camTest centralMemoryTest cmemRetentionTest cmiTest crossPortTest - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 663
sramRetentionTest command cannot be executed on an operational switch. You must first disable the switch using the switchDisable command. Operands This command To run a data retention test: switch:admin> sramretentiontest 2 Running SRAM Retention Test ... passed. Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 664
possible error messages if failures are detected: BUS_TIMEOUT REGERR REGERR_UNRST See the HP StorageWorks Fabric OS 5.x diagnostics and system error messages reference guide for more information. See also camTest centralMemoryTest cmiTest crossPortTest dataTypeShow itemList portLoopbackTest spinSilk - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 665
specified in use-bports are cleared; otherwise, the user ports specified in -uports clears. The default value is 0. Examples To clear port and diagnostic statistics: switch:admin> statsclear -bports 1/10-1/62 -use_bports 1 See also itemList Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 666
a link. This table is used for gathering statistics that match the link. This command is not supported on HP StorageWorks 4/8, 4/16, or 4/32 SAN switches and 4/256 SAN Director; use miniCycle or portLoopbackTest instead. Operands This command has the following optional operands: -passcnt count - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 667
error messages: DIAG-STSINIT DIAG-STSNULL DIAG-STSSID DIAG-STSXMIT DIAG-STSRCV DIAG-STSFRMCNT DIAG-STSWRDCNT DIAG-STSALPACNT See the HP StorageWorks Fabric OS 5.x diagnostics and system error messages reference guide for more information. See also camTest itemList Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 668
of user ports to test. By default, all the user ports in the switch are tested. See itemList help pages for further details. Examples To stop the portTest command: switch:admin> stopporttest See also crossPortTest fportTest loopPortTest portLoopbackTest portTest portTestShow spinFab 668 Fabric OS - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 669
supportftp -t hours supportftp -R Availability admin Description Use this command to set, clear, or display support FTP parameters or a time interval to check the FTP server. NOTE: If there is no time interval (in hours). -R Clears FTP parameters. Fabric OS 5.x command reference guide 669 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 670
-s -h 192.168.67.126 -u anonymous -d tracedump supportftp: ftp parameters changed. To display a time interval at which to check the FTP server: switch:admin> supportftp -t 24 supportftp: ftp check period changed. See also supportSave supportShow traceDump traceFtp traceTrig 670 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 671
command to save RASLOG, TRACE, and supportShow information and other support information to a remote FTP location. On a dual-CP reminds you whether or not a new trace dump needs to be generated manually before you run supportSave. Operands The operands are as follows: -n Does reference guide 671 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 672
RASLOG, TRACE, and supportShow information to an FTP server in interactive mode on a dual-CP system: switch:admin> supportsave This command will collect RASLOG, TRACE, supportShow and other support information and then transfer them to a FTP server. Only the local CP's information will be saved - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 673
supportShow traceDump traceFtp traceTrig Fabric OS 5.x command reference guide 673 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 674
switch information for debugging purposes. Synopsis supportshow [[slotnumber/]portnumber1-portnumber2] [lines] Availability all users Description Use this command to display support in this manual) • mii-tool • du • ps • rpm • dmesg • fstab • mtab • various proc entries • find core files • exception - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 675
portCamShow • cfgShow • cfgSize • rcssmshow • rcsregistryshow • zone mergeshow • services (ENABLED by default) • fdmiCacheShow • fdmiShow • nsShow • nsAllShow • and ipAddrShow) • tempShow • sensorShow • psShow • licenseShow • portFlagsShow • portCfgShow Fabric OS 5.x command reference guide 675 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 676
operands: slotnumber/portnumber1 -portnumber2 Specify the range of ports to display. If the slotnumber/portnumber parameter is omitted, all ports in the switch display in the per-port outputs. The slotnumber must be provided when specifying a range of ports on multi-bladed products. 676 Fabric - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 677
switch:admin> supportshow 1/1-3 supportshow groups enabled: system version: Kernel: 2.4.19 Fabric OS: v4.1.0 Made on: Fri Jan 10 01:06:10 2003 Flash: Thu Jan 17 00:06:52 2003 BootProm: 3.2.1 uptime: 10:49am up 3:25, 1 user, load average: 1.55, 1.20 Fabric OS 5.x command reference guide 677 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 678
See also supportFtp supportSave supportShowCfgDisable supportShowCfgEnable supportShowCfgShow traceDump traceFtp traceTrig 678 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 679
| exception | port | fabric | services | security | network | portlog | operands: os exception port fabric services security network portlog system extend filter fabric group commands Disables the service group commands Disables the security supportShow command: switch:admin> supportshowcfgdisable - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 680
Enables the port group commands Enables the fabric group commands Enables the service group commands Enables the security group commands Enables the network group enable a group of commands under the supportShow command: switch:admin> supportshowcfgenable os Config update Succeeded See also - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 681
To display which groups of commands are enabled in the supportShow command: switch:admin> supportshowcfgshow os enabled exception enabled port enabled fabric enabled services enabled security enabled network enabled portlog enabled system enabled extend disabled filter disabled - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 682
mode on or off. Synopsis switchbeacon [mode] Availability admin Description Use this command to enable or disable switch beaconing mode. When beaconing mode is turned on, the port LEDs flash amber, left to right and right to left, which continues until turned off - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 683
switch. All Fibre Channel ports are taken offline. If the switch was part of a fabric, the remaining switches reconfigure. The switch switch can be temporarily enabled using the switchEnable command. A temporarily enabled switch switch. Operands none Examples To disable a switch persistently: switch - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 684
at the end of the count down, then it assigns itself a domain ID. If another switch assumes the principal role, then this switch becomes a subordinate switch, and accepts a domain ID from the principal. See FC-SW for a complete description of this process. The enable process can be observed and - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 685
switch to a particular level. The configuration is saved in flash memory and persists across switch reboots or power cycles. If any port on the switch level for all ports on a switch: switch:admin> switchcfgspeed 0 Committing configuration...done. See also portCfgSpeed portShow Fabric OS - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 686
Enables or disables trunking on all the ports of a switch. Synopsis switchcfgtrunk mode Availability admin NOTE: This command requires an HP ISL Trunking license. Description Use this command to enable or disable trunking on all the ports of a switch. NOTE: You can disable or enable trunking using - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 687
switch. All Fibre Channel ports are taken offline; if the switch was part of a fabric, the remaining switches reconfigure. The switch require the switch to be disabled send an error if invoked while the switch is enabled. The switch does not To disable the switch: switch:admin> switchdisable See - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 688
can come online if connected to a device, or will remain offline if disconnected. Use switchEnable if you disable the switch to make configuration changes or to run diagnostics. If the switch is connected to a fabric, it rejoins the fabric. When this command is issued, the 10-second fabric stability - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 689
a new switch name. Enter this command with no operand to display the current switch name. Changing the switch name causes a domain address format RSCN to be issued (see FC-FLA for a description of RSCNs). The switch name also can be changed using HP - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 690
is equal to running switchShutdown and switchStart. NOTE: This command is not supported on single-domain systems. Operands none Examples To reboot an operational switch: switch:admin> switchreboot Stopping all switch daemons...Done. Powering off slot 1...Done. Powering off slot 4...Done. Checking - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 691
Displays the blade beaconing state (on or off). The switch summary is followed by one line per port: Area Slot Port Media Type Speed Part of the 24-bit port ID, which consists of domain, area number, Gb/s negotiated transfer speed Auto negotiating Unknown Fabric OS 5.x command reference guide 691 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 692
Port is disabled. Bypassed Port is bypassed (loop only). Loopback Port is in loopback mode. E_Port Fabric port; displays WWN and name of attached switch. F_Port Point-to-point port; displays WWN of attached N_Port. G_Port Point-to-point but not yet E_Port or F_Port. L_Port Loop port - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 693
ports on the switch. Example To display the port count: switch:admin> switchShow -portcount ports= 64 To display the port status for an E_Port: switch:user> switchshow E-Port See also ficonShow portCfgLongDistance switchDisable switchEnable switchName Fabric OS 5.x command reference guide 693 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 694
state, and disables all the ports and blades associated with the switch. NOTE: This command is not supported on single-domain systems. Operands none Examples To halt the operational switch: switch:admin> switchshutdown Stopping all switch daemons...Done. Powering off slot 1...Done. Powering off slot - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 695
all the ports and blades associated with the switch. NOTE: This command is not supported on single-domain systems. Operands none Examples To initialize the current switch: switch:admin> switchstart Initializing kernel modules...Done. Starting all switch daemons...Done. Powering on slot 1...Done - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 696
determine how many failed or faulty units of each contributor are allowed before triggering a status change in the switch from HEALTHY to MARGINAL or DOWN. The status of the switch can be found by issuing the switchStatusShow command. The existence of policies, such as Fans, PowerSupplies, WWN, CP - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 697
switch policies: switch:admin> switchstatuspolicyset To change the overall switch status policy parameters The current overall switch policy parameter is NOT applicable ** to the switch. Simply hit the Return key. Out of range Flash (0..64) [2] MarginalPorts contributing to MARGINAL status: (0..64) - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 698
. These policy parameters determine the number of failed or nonoperational units allowed for each contributor before triggering a status change in the switch. The command displays the current parameters in a three-column format, shown in Table 19. The first column indicates the contributor, the - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 699
overall switch status policy parameters: Down Marginal PowerSupplies 2 1 Temperatures 2 1 Fans 2 1 WWN 0 1 CP 0 1 Blade 0 1 Flash 0 1 MarginalPorts 2 1 FaultyPorts 2 1 MissingSFPs 0 0 See also switchStatusPolicySet switchStatusShow Fabric OS 5.x command reference guide 699 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 700
. In addition, users with a Fabric Watch license are able to view the list of unhealthy ports. This command displays the overall switch status, along with the status of each of the following contributors: • Power supplies • Temperatures • Fans • WWN servers (dual-CP systems only) • Standby CP (dual - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 701
Examples To display a switch health report: switch:user> switchstatusshow Switch Health Report 10:48:31 AM Switch Name: switch IP address: 10.10.255.255 SwitchState: MARGINAL Duration: switchStatusPolicyShow Report time: 06/19/2003 Fabric OS 5.x command reference guide 701 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 702
Description Use this command to display the current time and the amount of time that the switch has been operational. Operands none Examples To view the uptime for the switch: switch:user> switchuptime 9:50pm up for 20 mins See also switchReboot switchShutdown switchStart 702 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 703
0 through 7. This operand is optional; if omitted, the current facility is displayed. Examples To set the syslog facility to LOG_LOCAL1: switch:admin> syslogdFacility -l 1 Syslog facility changed to LOG_LOCAL1 See also syslogdIpAdd syslogdIpRemove syslogdIpShow Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 704
, depending on the system configuration. When one or more IP addresses are configured, the switch forwards all error log entries to the syslogd on the specified servers. Up to six servers are supported. Operands This command has the following required operand: ip_address Specify the IP address of - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 705
running syslogd. This operand is required. Examples To remove the address 192.168.1.60 from the list of machines to which system messages are sent: switch:admin> syslogdipremove 192.168.1.60 See also errModuleShow syslogdIpAdd syslogdIpShow Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 706
Use this command to display all syslog daemon IP addresses in the configuration database. Operands none Examples To display all syslog daemon IP addresses: switch:admin> syslogdipshow syslog.IP.address.1: 192.168.1.60 syslog.IP.address.2: 192.168.1.88 syslog.IP.address.3: 192.168.2.77 See also - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 707
switches in a system. The command initiates a burn-in run on all switches tests are designed to operate with switches connected to a fabric and parameters are copied to all switches in the system and , only BLADE is supported at this time. Since only one FRU type is supported, this parameter is - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 708
only in the log file. See the HP StorageWorks Fabric OS 5.x diagnostics and system error messages reference guide for more information. Examples To initiate a system verification test on all switches in the fabric: switch:admin> systemverification -short systemverification: Setting parameters for - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 709
See also burninErrClear burninStatus diagSetBurnin diagSetCycle Fabric OS 5.x command reference guide 709 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 710
the slot number (if applicable), the sensor state, and the temperature. The temperature readings are given in both Centigrade and Fahrenheit. See the hardware reference manual for your switch to determine the normal temperature range. Operands none Examples To display temperature and status sensors - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 711
login timeouts. This operand is optional; if omitted, the command displays the current timeout value. Examples To set the idle timeout to 10 minutes: switch:admin> timeout 10 IDLE Timeout Changed to 10 minutes The modified IDLE Timeout will be in effect after NEXT login See also none Fabric OS - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 712
fabric topology. Synopsis topologyshow [domain] Availability all users Description Use this command to display the fabric topology, as it appears to the local switch, including: • A list of all domains that are part of the fabric, and to each of those domains, all possible paths from the local - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 713
topologyshow 2 domains in the fabric; Local Domain ID: 1 Domain: 6 Metric: 500 Name: switch Path Count: 4 Hops: 1 Out Port: 60 In Ports: None Total Bandwidth: 2 Gbps Bandwidth : 1 58 None 2 Gbps 0 % D See also portRouteShow uRouteShow Fabric OS 5.x command reference guide 713 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 714
Use this command to initiate a background trace dump, to remove the content of a trace dump, or to display the dump status on the switch. NOTE: If there is no parameter specified, this command defaults to traceDump -S. The default remote file name format is chassisname-S#-YYYYMMDDHHMMSS.dmp, in - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 715
traceFtp traceTrig Fabric OS 5.x command reference guide 715 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 716
remotefile] Availability admin Description Use this command to display, enable, or disable trace auto-FTP or to retrieve a trace dump file from the switch to the FTP site immediately. NOTE: If there is no parameter specified, this command defaults to traceFtp -S. Default remote file name format for - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 717
remotefile should be less than 48 characters. Examples To retrieve a trace dump file: switch:admin> traceftp -n -h 192.168.67.126 -u anonymous -d tracedump -f dumpfile auto-FTP feature: switch:admin> traceftp -e trace auto-FTP enabled To disable the auto-FTP feature: switch:admin> traceftp -d - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 718
tracetrig -R [-s slot] Availability admin Description Use this command to set, remove, or display trace triggers for the specified slot on the switch. NOTE: If there is no parameter specified, this command defaults to tracetrig -S. Operands This command has the following mutually exclusive operands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 719
To remove all trace triggers: switch:admin> tracetrig -R all trace triggers are removed See also supportFtp supportSave supportShow traceFtp traceFtp Fabric OS 5.x command reference guide 719 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 720
to display information about the track-changes commands. Examples To display information on the track-changes feature commands: switch:admin> trackchangeshelp trackChangesSet Configure alert for login/logout/config update trackChangesShow Displays status of track changes See also trackChangesSet - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 721
from the track-changes feature is dumped to the error log for the switch. Use the errDump command or the errModuleShow command to view the error log enable the track-changes feature: switch:admin> trackchangesset 1, 1 Committing configuration...done. switch:admin> trackchangesshow Track changes - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 722
See also agtCfgSet agtCfgShow trackChangesHelp trackChangesShow 722 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 723
output from the track-changes feature is dumped to the error log for the switch. Use the errDump command or the errModuleShow command to view the error log. Examples To display the status of the track-changes feature: switch:admin> trackchangesshow Track changes status: ON Track changes generate - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 724
reports one of the following messages, based on the trunking properties of the two specified ports: • Switch does not support trunking • Trunking license required • Trunking not supported in switch interop mode • port port_id is not E_Port • port port_id trunking disabled • port port_id speed is not - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 725
See also portCfgTrunkPort switchCfgTrunk trunkShow Fabric OS 5.x command reference guide 725 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 726
corresponds to nanoseconds divided by 10. The firmware automatically sets the minimum deskew value of group. Operands none Examples To display trunking information for a switch: switch:admin> trunkshow 1: 6 -> 4 10:00:00:60: 69:51:43:04 deskew 16 deskew 15 deskew 17 deskew 16 MASTER 3:24 -> 14 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 727
primary FCS switch to an switch (when the security feature is enabled) connect to the NTP server and broadcast time service updates. All switches server that supports a full NTP client be be accessible from the switch. When a clock switches to view the NTP server FCS switch. Operands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 728
to an NTP server at the specified IP address and then verify that the new IP address was saved: switch:admin> tsclockserver LOCL switch:admin> tsclockserver "123.123.123.123" Updating Clock Server configuration...done. switch:admin> tsclockserver 123.123.123.123 See also date 728 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 729
error reporting and logging. An incorrect time zone setup do not affect the switch operation in any way. System services started during the switch bootup reflect a time-zone change only at the next reboot. Enter this -30, 0, or 30. This operand is optional. Fabric OS 5.x command reference guide 729 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 730
:admin> tsTimeZone Time Zone Hour Offset: 0 Time Zone Minute Offset: 0 switch:admin> tsTimeZone -3, -30 Updating Time Zone configuration...done. System Time Zone change will take effect at next reboot. switch:admin> tsTimeZone Time Zone Hour Offset: -3 Time Zone Minute Offset: -30 See also date - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 731
ports in the specified slot are tested. See the itemList command help page for more information. This operand is optional. Examples To execute this test: switch:admin> turboramtest -passcnt 2 -ports 2/0-2/63 Running Turbo RAM Test ........ passed. Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 732
the following error messages: DIAG-WTEST DIAG-INC_RWTEST DIAG-DEC_RWTEST DIAG-RAMINIT_TO See the HP StorageWorks Fabric OS 5.x diagnostics and system error messages reference guide for more information. See also centralMemoryTest cmemRetentionTest cmiTest portRegTest sramRetentionTest 732 Fabric OS - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 733
the TXA, TXD, and CMI data paths between the chips within a mini-switch. This is done by configuring all of the ports on the mini-switch in internal loopback and sending a frame from each quadrant to each other the first seven frames use unique data type. Fabric OS 5.x command reference guide 733 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 734
Operands This command has the following operands:- --slot slotnumber -nmegs count -lb_mode mode Specifies the slot number that the diagnostic will operate on. The ports specified will be relative to this slot number. The default is set to 0 and designed to operate on fixed-port-count products. - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 735
be used to restrict testing to the specified ports. Examples To run the txdPath test: switch:admin> txdpath Running TX Data Path Test .... Test Complete: "txdpath" Pass 10 of 10 XMIT See the HP StorageWorks Fabric OS 5.x diagnostics and system error messages reference guide for more information - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 736
, the time is displayed in minutes. The output format adjusts accordingly. Operands none Examples To display the length of time the system has been operational: switch:admin> uptime 12:03am up 4:56, 3 users, load average: 1.17, 1.08, 1.08 See also date fastBoot reboot 736 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 737
either an F_Port or an E_Port. NOTE: When using static routes, load sharing might be affected. The switch attempts to achieve optimum load sharing, but if too many routes are statically configured to use the same out_area port to which traffic is forwarded. Fabric OS 5.x command reference guide 737 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 738
configure a static route for all traffic coming in from port 1 and addressed to domain 2 to go through port 5: switch:admin> urouteconfig 1 2 5 done. switch:admin> urouteshow 1/1 2 Local Domain ID: 1 In Port Port) Domain Out Port Metric Hops Flags Next (Dom, 1 2 5 500 1 S 2,5 See - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 739
the destination domain of the static route to remove. Examples To remove a static route for all traffic coming in from port 1 and addressed to domain 2: switch:admin> urouteremove 1 2 done. See also dlsShow configShow uRouteConfig uRouteShow Fabric OS 5.x command reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 740
perform a port swap or enable extended-edge PID (PID Format 2) on a switch, the value is equal to the Area field displayed by the switchShow command. See HP StorageWorks Fabric OS 5.x Fabric Watch administrator's guide for more information regarding the extended-edge PID format. Destination domain - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 741
switch switch: switch:admin> urouteshow 1/11 Local Domain ID: 3 In Port Domain Out Port Metric Hops Flags Next (Dom, Port) 11 2 16 1500 2 D 4,16 4 16 500 1 D 4,16 To display the routing information of port 11 to domain 4 only: switch - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 742
command to add, delete, change or recover accounts are allowed only on the primary FCS switch. The primary FCS switch distributes the update to the entire fabric. As a result, all switches supporting customer-defined accounts will have the same account database. All accounts that not consistent with - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 743
Yes Not valid --add username -r rolename -d description Add a new account named username to the switch, with the given authorization of rolename. The -d option gives a text description for the new default accounts. 2. An account cannot delete itself. Fabric OS 5.x command reference guide 743 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 744
secure mode description. Once accounts have been recovered, the accounts in the backup database are still present. Examples To add a new account: switch:admin> userconfig --add joan -r admin -d "joan hoy" Setting initial password for joan Enter new password: Re-type new password: Account joan has - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 745
admin NOTE: This command is not supported on all platforms. Description Use this HP-specific default of admin and the user-level login name to the HP-specific default of user before enabling security; otherwise, the switch admin": switch:admin> userrename USERID admin See also secModeEnable - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 746
and the next reboot, the dates can differ. Operands none Examples To display the firmware version information in a switch: switch:admin> version Kernel: 2.4.19 Fabric OS: v4.4.0 Made on: Mon Oct 4 09:27:16 2004 Flash: Tue Oct 5 12:13:47 2004 BootProm: 3.1.18 See also firmwareDownload - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 747
levels One of the following values: CHASSIS, FAN, I2C, Control, CFlash, SW BLADE (switch), CP BLADE (control processor), or UNKNOWN. Slot or unit number, if applicable. The measured . Nonapplicable voltage levels are displayed as "--." Operands none Fabric OS 5.x command reference guide 747 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 748
Examples To display the voltage levels on a system: switch:admin> voltshow FRU TYPE - Number 1.8/1.2V 2.5V 3.3V 5V 12V 48V 53V SW BLADE Slot: 2 1.82 2.51 3.30 -- 11.94 -- -- SW BLADE Slot: 3 0.00 0.00 0. - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 749
WWN of a switch. All switches have a numeric address that is the unique Fibre Channel address used for communicating with the switch. The WWN command can be issued only from the primary FCS switch. Operands none Examples To display the switch WWN: switch:admin> wwn 10:00:00:60:69:00:54:e9 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 750
to the zone. Synopsis zoneadd "zoneName", "member;member" Availability admin NOTE: This command requires HP Advanced Zoning license, which is included within the Base Configuration Services and bundled with each B-series switch. Description Use this command to add one or more members to an existing - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 751
HP Advanced Zoning license, which is included within the Base Configuration Services and bundled with each B-series switch 64 switch number (domain ID) and p is the port area number. For example, 2, 20 specifies port area number 20 on switch switch or pair of switches • A switch domain and to switch 2, - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 752
to be added, in quotation marks, separated by semicolons. Valid values can be one or more of the following: • A switch domain and port area number pair; for example, 2, 20. View the area numbers for ports using the switchShow command. • Node or port WWN. • QuickLoop AL_PA. • Zone alias name - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 753
HP Advanced Zoning license, which is included within the Base Configuration Services and bundled with each B-series switch command can be issued only from the primary FCS switch. Operands This command has the following operand: the zone Blue_zone: switch:admin> zonedelete "Blue_zone" See also - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 754
Description Use this command to display help information for zone commands. Operands none Examples To display zone command help information: switch:admin> zonehelp aliAdd aliCreate aliDelete aliRemove aliShow Add a member to a zone alias Create a zone alias Delete a zone alias Remove a member - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 755
cfgDisable cfgEnable cfgSize cfgTransAbort faZoneAdd faZoneCreate faZoneDelete faZoneShow Fabric OS 5.x command reference guide 755 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 756
object. Synopsis zoneObjectCopy "objectName", "newName" Availability admin NOTE: This command requires HP Advanced Zoning license, which is included within the Base Configuration Services and bundled with each B-series switch. Description Use this command to copy a zone object to a new zone object - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 757
See also cfgAdd cfgClear cfgDelete cfgDisable cfgEnable cfgRemove cfgSave cfgShow zoneObjectRename Fabric OS 5.x command reference guide 757 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 758
a zone object. Synopsis zoneObjectExpunge "objectName" Availability admin NOTE: This command requires HP Advanced Zoning license, which is included within the Base Configuration Services and bundled with each B-series switch. Description Use this command to expunge a zone object. In addition, to - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 759
:0c:71:02 alias: array2 21:00:00:20:37:0c:76:22; 21:00:00:20:37:0c:76:28 alias: loop1 21:00:00:20:37:0c:76:85; 21:00:00:20:37:0c:71:df switch:admin> zoneObjectExpunge "White_zone" switch:admin> cfgShow Defined configuration: cfg: USA_cfg Red_zone; Blue_zone zone: Blue_zone 1,1; array1; 1,2; array2 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 760
object. Synopsis zoneObjectRename "objectName", "newName" Availability admin NOTE: This command requires HP Advanced Zoning license, which is included within the Base Configuration Services and bundled with each B-series switch. Description Use this command to rename a zone object. You can use this - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 761
See also cfgAdd cfgClear cfgDelete cfgDisable cfgEnable cfgRemove cfgSave cfgShow zoneObjectCopy Fabric OS 5.x command reference guide 761 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 762
requires HP Advanced Zoning license, which is included within the Base Configuration Services and bundled with each B-series switch. Description be one or more of the following: • A switch domain and port area number pair; for example, 2, 20. View the area numbers for ports using the switchShow - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 763
Examples To remove array2 from Blue_zone: switch:admin> zoneremove "Blue_zone", "array2" switch:admin> zoneremove "Blue_zone", "2,20" See also zoneAdd zoneCreate zoneDelete zoneShow Fabric OS 5.x command reference guide 763 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 764
requires HP Advanced Zoning license, which is included within the Base Configuration Services and bundled with each B-series switch. Description is enabled, this command can be issued only from the primary FCS switch. Operands The following operand is optional: pattern A POSIX-style regular - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 765
See also zoneAdd zoneCreate zoneDelete zoneRemove Fabric OS 5.x command reference guide 765 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 766
766 Fabric OS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 767
HP StorageWorks Fabric OS 5.x features overview. Advanced zoning commands The commands listed in Table 20 are available with the purchase of an HP Advanced Zoning license key. Table 20 . Zone Configuration cfgAdd Adds a zone to a zone configuration. Fabric OS 5.x command reference guide 767 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 768
Table 20 Zoning commands (continued) Command Description cfgCreate Creates a zone configuration. cfgDelete Deletes a zone configuration. cfgRemove Removes a zone from a zone configuration. Zone Management cfgClear Clears all zone - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 769
For more detailed information about trunking, see the HP StorageWorks Fabric OS 5.x procedures user guide. Table 24 HP trunking commands Command Description portCfgTrunkPort Configure a port for trunking. switchCfgTrunk Configure a switch for trunking. trunkDebug Debug a trunk link failure - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 770
Advanced Performance Monitoring commands The commands listed in Table 25 are available with the purchase of an HP Advanced Performance Monitoring license key. Table 25 Performance monitoring commands Command Description perfAddEEMonitor Add an end-to-end monitor to a port. perfAddIPMonitor - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 771
key. For more detailed information about security, see the HP StorageWorks Secure Fabric OS user guide.) Table 26 HP secure fabric OS commands Command Description secFabricShow Displays security related fabric information. secFCSFailover Enables a backup FCS switch to take over as primary FCS - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 772
772 Licensed product commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 773
FCS switches. cfgTransAbort Must be run from the primary FCS switch. cfgTransShow Must be run from the primary FCS switch. date This command can be run on all switches to view the current date. You can only modify the date from the primary FCS switch. Fabric OS 5.x command reference guide 773 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 774
faZoneCreate Must be run from the primary FCS switch. faZoneDelete Must be run from the primary FCS switch. faZoneRemove Must be run from the primary FCS switch. faZoneShow Must be run from the primary FCS switch. msConfigure Can be run on all switches, but it does not display ACL in secure - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 775
Must be run from the primary FCS switch. zoneCreate Must be run from the primary FCS switch. zoneDelete Must be run from the primary FCS switch. zoneRemove Must be run from the primary FCS switch. zoneShow Must be run from the primary FCS switch. Fabric OS 5.x command reference guide 775 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 776
776 Exclusive primary FCS commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 777
sets the authentication configuration. bannerSet Sets the banner on the local switch. bannerShow Displays the banner text. bcastShow Displays broadcast routing information. of the chassis. chassisName Displays or sets the chassis name for a switch. Fabric OS 5.x command reference guide 777 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 778
dynamic load sharing (DLS) option. dnsConfig Sets or displays domain name service (DNS) parameters. enclosureShow Displays attributes of the switch enclosure. errClear Clears all error log messages for all switch instances on this control processor (CP). errDelimiterSet Sets the error log - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 779
Link Service (ELS) ECHO switch firmware. firmwareDownload Downloads switch firmware from a remote host or local directory. firmwareDownloadStatus Displays the status of a firmware download. firmwareRestore Restores the former active firmware image. Fabric OS 5.x command reference guide - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 780
entire field replaceable unit (FRU) history log. httpCfgShow Displays the Java plug-in version. i Displays a task summary. ifModeSet Sets the FSPF interface information. interopMode Enables or disables HP switch interoperability with switches from other manufacturers. iodReset Turns off the - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 781
the Management Server (MS) platform service database control block. msPlClearDB Clears the Management Server (MS) platform database on all switches in the fabric. msPlMgmtActivate Activates cache. nsShow Displays local Name Server (NS) information. Fabric OS 5.x command reference guide 781 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 782
port group or for all port groups in the switch. portCamShow Displays port-based filter CAM utilization. portCfg port. portCfgLongDistance Configures a port to support long-distance links. portCfgLPort Locks a port to be enabled or disabled for HP ISL Trunking license. portDebug Sets debug - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 783
port status. portStats64Show Displays the 64-bit hardware statistics for a port. portStatsClear Clears the hardware statistics of a specified switch port. portStatsShow Displays port hardware the portswap feature. psShow Displays power supply status. Fabric OS 5.x command reference guide 783 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 784
either one control processor (CP) or the entire system. routeHelp Displays a list of FSPF-related commands. saveCore Saves or removes core files created by daemons. secHelp Displays information about security commands. sensorShow Displays sensor readings. setDbg Sets debug level of the - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 785
all syslog daemon IP addresses. systemVerification Runs a suite of diagnostic tests on all switches in a fabric. tempShow Displays temperature readings. timeout Sets or displays the idle timeout FTPsa trace dump file to the customer FTP server. Fabric OS 5.x command reference guide 785 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 786
Displays unicast routing information. userConfig Manages user accounts. version Displays firmware version information. voltShow Displays current level of the voltage sensors on a system. wwn Displays a switch world wide name (WWN). zoneHelp Displays help information for zone commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 787
CP and standby CP in an HP StorageWorks Core Switch 2/64, HP StorageWorks SAN Director 2/128, or HP StorageWorks 4/256 SAN Director. Commands supported on the active CP When logged in to the active CP on a Core Switch 2/64, you must specify the logical switch number to which you are connecting - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 788
Table 29 Commands supported on the standby CP (continued) Command Description itemList Lists parameter or remove core files generated by daemons. switchName Print this switch's name. tsTimeZone Display time zone. upTime Print how long switch has been up. version Print firmware version. - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 789
executed by that group. NOTE: Many of the commands executed by supportShow are intended for support use only. These commands are not intended for end users. Table 30 supportShow command groups bin/cat /etc/mtab printing proc entries. errdump -a/-p Fabric OS 5.x command reference guide 789 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 790
portsemshow bloomsemshow semashow 1 fabric fabricShow islShow trunkShow topologyShow fashow qlshow cfgShow fabStatsShow fablogdump services nsShow nsAllShow nscamShow security network portlog secModeShow secPolicyDump secStatsShow secFabricShow ipAddrShow ifshow ipstatshow udpstatshow - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 791
portCfgShow sfpShow portErrShow fwSamShow agtCfgShow slotShow chassisShow switchStatusPolicyShow fwAlarmsFilterShow timeout historyShow configShow ptbufshow ptcreditshow ptDataShow ptPhantomShow ptPropShow ptStatsShow filterportshow ps_dump -a -n port# Fabric OS 5.x command reference guide 791 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 792
: 200MHz revision : 1.69 (pvr 4011 0145) bogomips : 199.47 machine : Brocade Silkworm plb bus clock : 100MHz pci bus clock : 33MHz /proc/devices /proc/ cua 7 vcs 10 misc 89 i2c 90 mtd 128 ptm 136 pts 162 raw 245 swd 246 ham 247 fc 248 fc-switch 249 fabsys 250 fss_kt 251 fss_data 252 fss_mgmt 253 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 793
"log data (1)" mtd6: 00400000 00040000 "log data (2)" /proc/partitions /proc/partitions major minor #blocks name 3 0 250880 hda 3 1 124912 hda1 3 2 124928 hda2 Fabric OS 5.x command reference guide 793 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 794
0 1 tcp_tw_bucket 2 40 96 1 1 1 tcp_bind_bucket 5 113 32 1 1 1 tcp_open_request 0 59 64 0 1 1 inet_peer_cache 1 59 64 1 1 1 ip_fib_hash 11 113 32 1 1 1 ip_dst_cache 65 168 160 7 7 1 arp_cache 2 30 128 1 1 1 blkdev_requests 128 160 96 4 4 1 xfs_chashlist 193 404 16 2 2 1 xfs_ili 2004 5668 152 135 218 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 795
/version /proc/version Linux version 2.4.19 (swrel@sierra) (gcc version 2.95.3 20010112 (prerelease)) #1 Wed Mar 26 00:04:35 PST 2003 Fabric OS 5.x command reference guide 795 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 796
796 supportShow reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 797
each 8-bit byte into 10 bits. Used to balance 1s and 0s in high-speed transports. A 24-bit or 8-bit value used support up to 126 devices and one fabric attachment. See also topology. A method of gaining orderly access to a shared-loop topology. In HP Fabric OS v4.0 and above, ports on a switch - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 798
new firmware to SANs by allowing the networking of multiple FC routers, which connect to the backbone fabric via EB_Port interfaces. backup FCS switch Relates to the HP bit error rate. Bloom The code name given to the third-generation HP Fabric ASIC. This ASIC is used in StorageWorks 2 GB switches - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 799
cascade Two or more interconnected Fibre Channel switches. HP StorageWorks 1 GB/s switches and later switches can be cascaded up to 239 switches, with a recommended maximum of seven interswitch links (no path longer than eight switches). See also fabric, ISL. CDR Clock and data recovery circuitry - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 800
of a switch. Use the configShow command to view the current configuration of your switch. 2) In HP Zoning, a of the peripheral device. COS Class of service. CP Control processor. CRC Cyclic redundancy check to nanoseconds divided by 10. The firmware automatically sets the minimum deskew value - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 801
Usually automatically assigned by the principal switch but can be assigned manually. The domain ID for an HP StorageWorks switch can be any integer between 1 parameters. Extended link service. ELSs are sent to the destination N_Port to perform the requested function or service. ELS is a Fibre - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 802
as hosts and storage. Also referred to as a switched fabric. See also cascade, SAN, topology. A device that enables fabric-based storage applications such as mirroring, data migration, snapshots, and virtual tape. The HP StorageWorks Fabric Application Platform can run in a central location, process - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 803
when a loop reinitializes, if the switch supports FAN. The ratio of hosts to storage devices; the view of the SAN from the storage port's perspective. The usage. Layer of Fibre Channel transport that contains common services used by multiple N_Ports in a node. Layer of 5.x command reference guide 803 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 804
other tasks. The HP Multiprotocol SAN Routing Service that enables SANs to span longer distances than could be supported with native Fibre Channel and algorithms for the interconnection and initialization of Fibre Channel switches to create a multiswitch Fibre Channel fabric. Fibre Distributed Data - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 805
between Fibre Channel service providers. See also FSP. A protocol used on IBM mainframes. HP StorageWorks switch FICON support enables an HP StorageWorks fabric to transmit FICON format data between FICON-capable servers and storage. Fabric ID. Unique identifier of a fabric in a meta-SAN. An IDLE or - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 806
and gigabit Ethernet. Gb/s Gigabits per second (1,062,500,000 bits/second). GB/sec Gigabytes per second (1,062,500,000 bytes/ such as HP Advanced Web Tools arbitrated-loop topology and HP Fabric Manager. HA High availability. A set of features in HP StorageWorks switches that is designed - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 807
. host A computer system that provides end users with services like computation and storage access. hot swappable A hot support FICON® traffic. integrated fabric The fabric created by an HP StorageWorks SAN Switch Integrated/64, consisting of six HP StorageWorks 1 GB switches guide 807 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 808
and transporting them over the network via IP. iSCSI Gateway Service The HP multiprotocol SAN routing service that maps the FCP protocol to the IP transport. This service projects iSCSI hosts onto the backbone fabric of a gateway switch. ISL Interswitch link. A Fibre Channel link from the E_Port - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 809
or node resetting. Loop-initialization previously assigned. The device marks a bit in the bitmap if it did not log in with the fabric name given to the second-generation HP Fabric ASIC. This is the ASIC used in the StorageWorks 1 GB switches. A temporary bidirectional communication path guide 809 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 810
cabling that is based on 1300-mm lasers and supports link speeds of 1.0625 Gb/sec. Can also HP Fibre Channel Routing Service or FC-to-FC routing (for instance, the StorageWorks SAN) management application to retrieve information and administer the fabric and interconnected elements, such as switches - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 811
OFC OLS ON OPN Multiprotocol SAN Routing Services. An optionally licensed software bundle available on certain HP platforms, such as the HP StorageWorks MP Router, that includes the Fibre Channel Routing Service, the iSCSI Gateway Service, and the FCIP Tunneling Service. Mean time between failures - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 812
simultaneously support Array Logic. A relatively small FPD. parallel The simultaneous transmission of data bits An HP StorageWorks switch switch instead of to RAM. These messages are saved over reboots and power cycles, constituting the persistent error log. Note that each CP on a StorageWorks 2/64 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 813
In an HP StorageWorks switch environment, an SFP or GBIC receptacle on a switch to which supports arbitrated-loop protocol and can interpret 8-bit addresses but cannot log in to the fabric. private key The secret half of a key pair. See also key, key pair. Fabric OS 5.x command reference guide - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 814
PSU Power supply unit. public device A device that supports arbitrated-loop protocol, can interpret 8-bit addresses, and can log in to the fabric. public sending them to the loop. QuickLoop An HP software product that allows multiple ports on a switch to create a logical loop. Devices - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 815
rate The rate at which requests arrive at a servicing entity. resilience A fabric's ability to adapt to or tolerate a failure of a component within the fabric. resilient core/edge Two or more switches acting as a core to interconnect multiple edge switches. Nodes attach to topology the edge - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 816
SAN. scalability One of the properties of a SAN: the size to which a SAN topology can grow port and switch can be customized through HP Secure Fabric OS or HP Fabric Manager. SEQ_ID service rate The rate at which an entity can service requests. See also request rate. SES SCSI Enclosure Services - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 817
service or name server. Single CP Mode The -s option of the firmwareDownload command. Using firmwareDownload -s enables Single CP Mode. In the StorageWorks 2/64 . SLP Service Location Protocol. SMDS Switched Multimegabit Data Service. A good storage area network (SAN) resources. SNA/SDLC - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 818
SPOF Single point of failure. Any component in a SAN whose malfunction could bring down the entire SAN. SSH Secure shell. Used starting in HP Fabric OS v4.1 to support encrypted telnet sessions to the switch. SSH encrypts all messages, including the client sending the password at login. - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 819
server resources. track changes An HP Fabric OS feature that can be the fabric. transmission character A 10-bit character encoded according to the rules of different type of network. TX Transmit. U_Port Universal port. A switch port that can operate as a G_Port, E_Port, F_Port, or guide 819 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 820
Channel standards as assigned to a specific function and stored on the switch. workstation A computer used to access and manage the fabric. Also "management station" or "host." WTV Write timeout value. Refers to an ELS field that appears in portLogDump command output. WWN world wide name. An - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 821
A AAA services 22 aaaConfig AAA services RADIUS access agtCfgDefault 25 SNMP agtCfgSet 29 SNMP agtCfgShow 32 SNMP aliAdd 35 Advanced Zoning license exclusive 13 authentication configuration 52, 777 authorized reseller, HP 15 authUtil 52 B backplaneTest 54 backport 56 5.x command reference guide 821 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 822
SNMP configuration arbitrated loop parameters 127 authentication 52, 777 fabric parameters 128 822 Index NS operation parameters 127 portlog events enable 128 RSCN transmission mode 127 system services 128 virtual channel settings 126 zoning operation parameters 126 configure 123 SNMP conventions - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 823
209 Fabric OS Command Line Interface 18 fabric parameters configuration 128 Fabric Watch 99 Fabric Watch license 700 Fabric Watch commands FCS commands Fabric Assist fcpLogClear 210, 213 fcpLogDisable 214 fcpLogEnable 215 fcpLogShow 216 fcpProbeShow 218 Fibre Channel Protocol fcpRlsShow 220 Fibre - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 824
292 help 293 standby CP commands help, obtaining 15 historyLastShow 294 historyMode 295 historyShow 296 HP authorized reseller 15 storage web site 15 Subscriber's choice web site 15 technical support 15 httpCfgShow 299 I i 300 ifModeSet 302 standby CP commands ifModeShow 304 standby CP commands - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 825
Monitor license Performance Monitor license perfAddEEMonitor 395 perfAddIPMonitor 397 perfAddReadMonitor 399 perfAddRWMonitor 401 perfAddSCSIMonitor 403 perfAddUserMonitor 405 perfAddWriteMonitor 407 perfCfgClear 409 Fabric OS 5.x command reference guide 825 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 826
468 portDisable 469 SNMP portEnable 470 SNMP portErrShow 471 portFlagsShow 473 SNMP portLedTest 475 portlog events enable configuration 128 portLogClear 476 portLogConfigShow 477 portLogDump 478 portLogDumpPort 480 portLogEventShow 482 826 Index portLoginShow 484 portLogPdisc 486 portLogReset 489 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 827
609 secTempPasswdSet 611 secTransAbort 613 Secure Fabric OS commands 771 secVersionReset 614 secVersionReset 614 exclusive primary FCS commands Secure Fabric OS Fabric OS 5.x command reference guide 827 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 828
agtCfgDefault 777 agtCfgSet 777 agtCfgShow 32, 777 configDefault 113 configUpload 121 configure 128 portDisable 469 portEnable 470 680 supportShowCfgShow 681 switch enclosure 167 switchBeacon 706 system services configuration 128 systemVerification 707 T technical support, HP 15 tempShow - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 829
746 standby CP commands virtual channel settings configuration 126 voltShow 747 W web sites HP storage 15 HP Subscriber's choice 15 wwn 749 exclusive primary FCS commands Z zoneAdd 750 Advanced Zoning 764 zoning operation parameters configuration 126 Fabric OS 5.x command reference guide 829 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 830
830 Index
HP StorageWorks
Fabric OS 5.x
command reference guide
Part number: AA–RVHVB–TE
Second edition: September 2005