- HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 1
HP StorageWorks Fabric OS 5.x MIB reference guide Part number: AA-RVHXB-TE Second edition: September 2005 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 2
and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. Fabric OS 5.x MIB reference guide - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 3
Contents About this guide 25 Intended audience 25 Related documentation 25 HP StorageWorks Fabric OS 5.x master glossary 25 Document conventions and symbols 26 HP technical support 26 HP-authorized reseller 27 Helpful web sites 27 1 Understanding HP SNMP 29 Understanding SNMP basics 29 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 4
ifInDiscards 45 ifInErrors 45 ifInUnknownProtos 45 ifOutOctets 45 ifOutUcastPkts 45 ifOutNUcastPkts 45 ifOutDiscards 46 ifOutErrors 46 ifOutQLen 46 ifSpecific 46 Address translation group 46 Address translation table 46 atTable 46 atEntry 47 atIfIndex 47 atPhysAddress 47 atNetAddress - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 5
58 tcpRetransSegs 58 TCP connection table 59 tcpConnTable 59 tcpConnEntry 59 tcpConnState 59 tcpConnLocalAddress 59 tcpConnLocalPort 60 tcpConnRemAddress 60 tcpConnRemPort 60 Fabric OS 5.x MIB reference guide 5 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 6
63 snmpInTotalSetVars 63 snmpInGetRequests 63 snmpInGetNexts 64 snmpInSetRequests 64 snmpInGetResponses 64 snmpInTraps 64 snmpOutTooBigs 64 snmpOutNoSuchNames 64 snmpOutBadValues 64 snmpOutGenErrs 64 snmpOutGetRequests 65 snmpOutGetNexts 65 snmpOutSetRequests 65 snmpOutGetResponses - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 7
76 fcFxPortEntry 76 fcFxPortIndex 76 fcFxPortName 76 Fx_Port common service parameters 76 fcFxPortFcphVersionHigh 76 fcFxPortFcphVersionLow 76 fcFxPortBbCredit 77 fcFxPortRxBufSize Fx_Port error table 83 fcFxPortErrorTable 83 fcFxPortErrorEntry 83 Fabric OS 5.x MIB reference guide 7 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 8
fcFxPortLinkFailures 83 fcFxPortSyncLosses 83 fcFxPortSigLosses 83 fcFxPortPrimSeqProtoErrors 83 fcFxPortInvalidTxWords 83 fcFxPortInvalidCrcs 83 fcFxPortDelimiterErrors 84 fcFxPortAddressIdErrors 84 fcFxPortLinkResetIns 84 fcFxPortLinkResetOuts 84 fcFxPortOlsIns 84 fcFxPortOlsOuts 84 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 9
fcFxPortBbCreditAvailable 102 fcFxPortOperMode 102 fcFxPortAdminMode 102 Fx_Port physical level table 102 fcFxPortPhysTable 102 fcFxPortPhysEntry 102 fcFxPortPhysModuleIndex 103 fcFxPortPhysFxPortIndex 103 fcFxPortPhysAdminStatus 103 Fabric OS 5.x MIB reference guide 9 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 10
fcFxPortPhysOperStatus 103 fcFxPortPhysLastChange 103 fcFxPortPhysRttov 104 Fx_Port fabric login table 104 fcFxlogiTable 104 fcFxlogiEntry 104 fcFxlogiModuleIndex 104 fcFxlogiFxPortIndex 104 fcFxlogiNxPortIndex 104 fcFxPortFcphVersionAgreed 104 fcFxPortNxPortBbCredit 105 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 11
126 entAliasMappingIdentifier 127 entPhysicalContainsTable 127 entPhysicalContainsEntry 127 entPhysicalChildIndex 128 General group 128 entLastChangeTime 128 Entity MIB trap 128 entConfigChange 128 Entity MIB conformance information 129 entityCompliance 129 entity2Compliance - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 12
entityPhysicalGroup 130 entityLogicalGroup 130 entityMappingGroup 130 entityGeneralGroup 131 entityNotificationsGroup 131 entityPhysical2Group 131 entityLogical2Group 131 5 SW MIB objects 133 SW MIB overview 133 SW-MIB system organization of MIB objects 133 Text conventions for SW-MIB 139 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 13
162 swFCPortNoTxCredits 162 swFCPortRxEncInFrs 162 swFCPortRxCrcs 162 swFCPortRxTruncs 163 swFCPortRxTooLongs 163 swFCPortRxBadEofs 163 swFCPortRxEncOutFrs 163 swFCPortRxBadOs 163 swFCPortC3Discards 163 swFCPortMcastTimedOuts 163 Fabric OS 5.x MIB reference guide 13 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 14
swFCPortTxMcasts 163 swFCPortLipIns 163 swFCPortLipOuts 164 swFCPortLipLastAlpa 164 swFCPortWwn 164 swFCPortSpeed 164 swFCPortName 164 swFCPortSpecifier 164 Name server database group 165 swNsLocalNumEntry 165 swNsLocalTable 165 swNsLocalEntry 165 swNsEntryIndex 165 swNsPortID 165 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 15
178 swEndDeviceProtoErr 178 swEndDeviceInvalidWord 178 swEndDeviceInvalidCRC 178 Switch group 178 swGroupTable 178 swGroupEntry 178 swGroupIndex swBlmPerfEERefKey 181 swBlmPerfEECRC 181 swBlmPerfEEFCWRx 181 swBlmPerfEEFCWTx 181 swBlmPerfEESid 181 Fabric OS 5.x MIB reference guide 15 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 16
cpIpAddress 190 cpIpMask 190 cpIpGateway 191 cpLastEvent 191 HA-MIB traps 191 fruStatusChanged 191 cpStatusChanged 192 fruHistoryTrap 192 HA-MIB traps and sample triggers 193 16 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 17
205 rLIRTableNumEntries 205 rLIRTable 205 rLIREntry 205 rLIRIndex 206 rLIRIncidentPortWwn 206 rLIRIncidentNodeWwn 206 rLIRIncidentPortType 206 rLIRIncidentPID 206 rLIRIncidentPortNumber 206 rLIRConnectedPortWwn 206 Fabric OS 5.x MIB reference guide 17 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 18
FibreAlliance MIB objects 209 FA MIB overview 209 FCMGMT-MIB system organization of MIB objects 209 Definitions for FCMGMT-MIB 215 ConnSet group 216 uNumber 216 systemURL 216 Connectivity unit table 217 connUnitTable 217 connUnitEntry 217 connUnitId 217 connUnitGlobalId 218 connUnitType - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 19
connUnitPortRevision 231 connUnitPortVendor 231 connUnitPortSpeed 232 connUnitPortControl 232 connUnitPortName 233 connUnitPortPhysicalNumber 233 239 connUnitLinkPortWwnX 239 connUnitLinkNodeIdY 240 connUnitLinkPortNumberY 240 connUnitLinkPortWwnY 240 Fabric OS 5.x MIB reference guide 19 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 20
249 connUnitPortStatCountInvalidOrderedSets 249 connUnitPortStatCountFramesTooLong 249 connUnitPortStatCountFramesTruncated 249 connUnitPortStatCountAddressErrors 249 connUnitPortStatCountDelimiterErrors 250 connUnitPortStatCountEncodingDisparityErrors 250 20 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 21
Connectivity unit service scalars group 250 connUnitSnsMaxEntry 250 Connectivity unit service tables 256 connUnitPortStatusChange 256 A MIB object groupings 257 Switch variables 257 Sensor variables 257 Port variables 257 structure 29 2 SNMP query 29 Fabric OS 5.x MIB reference guide 21 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 22
3 SNMP trap 29 4 HP MIB tree location 30 5 HP SNMP MIB dependencies and advised hierarchy 40 16 fcFeMIB hierarchy 68 17 fcFeConfig hierarchy 68 18 fcFeStatus Hierarchy 69 19 fcFeError hierarchy 69 20 fcFeAccounting hierarchy 31 entityMapping hierarchy 112 32 entityGeneral hierarchy 112 33 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 23
15 Objects imported into the HA-MIB 186 16 Valid FRU counts for HP StorageWorks Switches 187 17 HA-MIB traps and examples of triggers 193 18 Objects and imported into the FICON MIB 198 19 FICON MIB text conventions 198 20 NodeRNIDEntry objects and object types 200 21 SwitchRNIDEntry objects - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 24
24 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 25
not supported on HP B-Series Fibre Channel switches. The FICON information in this document is included for reference only. Intended audience This guide is intended for: • System administrators responsible for setting up HP StorageWorks Fibre Channel Storage Area Network (SAN) switches • Technicians - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 26
clarifying information or specific instructions. NOTE: Provides additional information. TIP: Provides helpful hints and shortcuts. HP technical support Telephone numbers for worldwide technical support are listed on the HP support web site: http://www.hp.com/support/. Collect the following - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 27
sign up online using the Subscriber's choice web site: http://www.hp.com/go/e-updates. • Subscribing to this service provides you with e-mail updates on the latest product enhancements, newest versions of drivers, and firmware documentation updates as well as instant access to numerous other product - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 28
28 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 29
Every HP StorageWorks switch or director supports SNMP. This chapter discusses the following: • Understanding SNMP basics next • Loading HP MIBs, page 32 Understanding SNMP basics Every HP StorageWorks switch carries send traps to up to six management stations. Fabric OS 5.x MIB reference guide 29 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 30
HP StorageWorks switch are referenced in the remainder of this manual. iso (1) org (3) dod (6) internet (1) HP HP supports version 3.0. • Fabric Element (FE) MIB: accepted by the Internet Engineering Task Force (IETF). HP supports HP MIBs" on page 32 for more information. 30 Understanding - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 31
an HP StorageWorks director in your environment: • fruStatusChanged: This trap is generated by a FRU status change, such as a switch reboot or adding or removing a FRU component. • cpStatusChanged: This trap is generated by a change in the status of a CP, including a reboot, or firmware download - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 32
See the HP StorageWorks Fabric OS 5.x command reference guide for more 32 • "MIB loading order" on page 33 Before loading MIBs Before loading HP MIB files, ensure that you have the correct version of SNMP for your Fabric OS version (see Table 2). Table 2 Fabric OS supported SNMP versions Firmware - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 33
SNMPv1. Fabric 2.6.x and 3.2.x partially support SNMPv2. Fabric OS 4.4.0 and 5.x support SNMPv3-USM (snmpUsmMIB) MIB. HP MIB files The following HP MIBs can be found in a mibs subdirectory after uncompressing the 5.x firmware file. • BRCD_v5_0.mib • SW_v5_2.mib Fabric OS 5.x MIB reference guide 33 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 34
the HP StorageWorks Fabric OS 5.x administrator guide for procedures on configuring SNMP on the HP StorageWorks switches. is retained for legacy reasons but is replaced functionally by the snmpMibCapShow command. Firmware upgrades and enabled traps Prior to Fabric OS 4.4, traps were turned on and - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 35
the MIB-II itself. The notes that follow the descriptions refer to HP-specific information. MIB-II object hierarchy Figure 6 through Figure 15 depicts the - sysUpTime (3) - sysContact (4) - sysName (5) - sysLocation (6) - sysServices (7) Figure 7 System hierarchy Fabric OS 5.x MIB reference guide 35 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 36
ifInUnknownProtos (15) - ifOutOctets (16) - ifOutUcastPkts (17) - ifOutNUcastPkts (18) - ifOutDiscards (19) - ifOutErrors (20) - ifOutQLen (21) - ifOutUcastPkts (17) - ifOutNUcastPkts (18) - ifOutDiscards (19) - ifOutErrors (20) - ifOutQLen (21) - ifSpecific (22) Figure 8 Interfaces hierarchy - - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 37
14) - ipReasmOKs (15) - ipReasmFails (16) - ipFragOKs (17) - ipFragFails (18) - ipFragCreates (19) - ipAddrTable (20) - ipAddrEntry (1) - ipAdEntAddr (1) - (9) - ipRouteAge (10) - ipRouteMask (11) - ipRouteMetric5 (12) - ipRouteInfo (13) Figure 10 IP hierarchy Fabric OS 5.x MIB reference guide 37 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 38
(15) - icmpOutDestUnreachs (16) - icmpOutTimeExcds (17) - icmpOutParmProbs (18) - icmpOutSrcQuenchs (19) - icmpOutRedirects (20) - icmpOutEchos (21) (25) - icmpOutAddrMaskReps (26) - icmpOutSrcQuenchs (19) - icmpOutRedirects (20) - icmpOutEchos (21) - icmpOutEchoReps (22) - icmpOutTimestamps (23 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 39
- egpNeighOutErrs (7) - egpNeighInErrMsgs (8) - egpNeighOutErrMsgs (9) - egpNeighStateUps (10) - egpNeighStateDowns (11) - egpNeighIntervalHello (12) - egpNeighIntervalPoll (13) - egpNeighMode (14) - egpNeighEventTrigger (15) - egpAs (6) Figure 14 EGP hierarchy Fabric OS 5.x MIB reference guide 39 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 40
(12) - snmpInTotalReqVars (13) - snmpInTotalSetVars (14) - snmpInGetRequests (15) - snmpInGetNexts (16) - snmpInSetRequests (17) - snmpInGetResponses (18) - snmpInTraps (19) - snmpOutTooBigs (20) - snmpOutNoSuchNames (21) - snmpOutBadValues (22) - snmpOutGenErrs (24) - snmpOutGetRequests (25 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 41
. Default Value = Fibre Channel Switch. Set this value using the to contact this person. Default value = Field Support. Set this value using the agtCfgSet command. domain name. Default value = preassigned name of the switch. sysLocation OID Description Note 1.3.6.1.2.1.1.6 The physical location of - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 42
of 4 (23-1). In contrast, a node that is a host and offers application services has a value of 72 (24-1 + 27-1). Note that in the context of the value is 5 for the SAN Director 2/128 and 4/256 SAN Director (single domain), 7 for the Core Switch 2/64 or the SAN Director 2/128 (dual-domain). All non- - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 43
system to the next reinitialization. For example, the number of entries inside the Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director is 1, 2, or 3 for FCIP; otherwise, the value is 1 or OS 4.x). fei0 returns 1500. lo0 returns 3904. fc0 returns 2024. Fabric OS 5.x MIB reference guide 43 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 44
Note ifAdminStatus OID Description Note ifOperStatus OID Description Note ifLastChange OID Description ifInOctets OID Description 1.3.6.1.2.1.2.2.1.5 An estimate (in bits per second) of the interface's current bandwidth. For interfaces that do not vary in bandwidth or interfaces for which - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 45
were discarded because of an unknown or unsupported protocol. ifOutOctets OID Description 1.3.6.1.2.1.2.2.1.16 The total number of octets transmitted out of the interface, including framing subnetwork-multicast), including those that were discarded or not sent. Fabric OS 5.x MIB reference guide 45 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 46
their being transmitted. One possible reason for discarding such a packet could be to free buffer space. ifOutErrors OID Description 1.3.6.1.2.1.2.2.1.20 The number of outbound packets that could not be transmitted because of errors. ifOutQLen OID Description 1.3.6.1.2.1.2.2.1.21 The length of - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 47
checksums, version number mismatch, other format errors, time-to-live exceeded, errors discovered in processing their IP options, and so forth. Fabric OS 5.x MIB reference guide 47 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 48
does not include any datagrams counted in ipForwDatagrams. ipOutDiscards OID Description 1.3.6.1.2.1.4.11 The number of output IP datagrams for which no problem was encountered to prevent their transmission to their destination, but which were discarded (for example, for lack of buffer space). 48 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 49
needed to be reassembled at this entity. 1.3.6.1.2.1.4.15 The number of IP datagrams successfully reassembled. 1.3.6.1.2.1.4.16 The number of failures detected by the IP reassembly algorithm (for whatever reason: timed out, their Don't Fragment flag was set). Fabric OS 5.x MIB reference guide 49 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 50
entry. The value of the mask is an IP address with all the network bits set to 1 and all the host bits set to 0. ipAdEntBcastAddr OID Description 1.3.6.1.2.1.4.20.1.4 The value of the least-significant bit in the IP broadcast address used for sending datagrams on the (logical) interface associated - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 51
value. If this metric is not used, its value should be set to -1. 1.3.6.1.2.1.4.21.1.5 An alternate routing metric for this route. Fabric OS 5.x MIB reference guide 51 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 52
mechanism via which this route was learned. Inclusion of values for gateway routing protocols is not intended to imply that hosts should support those protocols. 1.3.6.1.2.1.4.21.1.10 The number of seconds since this route was last updated or otherwise determined to be correct. Older semantics - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 53
being compared to the value in the ipRouteDest field. For those systems that do not support arbitrary subnet masks, an agent constructs the value of the ipRouteMask by determining whether physical address equivalence. ipNetToMediaIfIndex, ipNetToMediaNetAddress Fabric OS 5.x MIB reference guide 53 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 54
ipNetToMediaIfIndex OID 1.3.6.1.2.1.4.22.1.1 Description The interface on which this entry's equivalence is effective. Note The interface identified by a particular value of this index is the same interface identified by the same value of ifIndex. ipNetToMediaPhysAddress OID 1.3.6.1.2.1.4.22 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 55
messages received. icmpInParmProbs OID Description 1.3.6.1.2.1.5.5 The number of ICMP Parameter Problem messages received. icmpInSrcQuenchs OID Description 1.3.6.1.2.1.5.6 The number of ICMP Source The number of ICMP Address Mask Reply messages received. Fabric OS 5.x MIB reference guide 55 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 56
messages that this entity did not send due to problems discovered within ICMP, such as a lack of counter's value. icmpOutDestUnreachs OID 1.3.6.1.2.1.5.16 Description The number of ICMP messages sent. icmpOutRedirects OID Description 1.3.6.1.2.1.5.20 The number of ICMP Redirect messages - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 57
time-out algorithm is 3 (rsre), an object of this type has the semantics of the UBOUND quantity described in RFC 793. Fabric OS 5.x MIB reference guide 57 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 58
tcpMaxConn OID Description 1.3.6.1.2.1.6.4 The limit on the total number of TCP connections the entity can support. In entities where the maximum number of connections is dynamic, this object should contain the value -1. tcpActiveOpens OID Description 1.3.6.1.2.1.6.5 The number of times TCP - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 59
the listen state that is willing to accept connections for any IP interface associated with the node, the value 0.0.0.0 is used. Fabric OS 5.x MIB reference guide 59 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 60
tcpConnLocalPort OID Description 1.3.6.1.2.1.6.13.1.3 The local port number for this TCP connection. tcpConnRemAddress OID 1.3.6.1.2.1.6.13.1.4 Description The remote IP address for this TCP connection. tcpConnRemPort OID Description 1.3.6.1.2.1.6.13.1.5 The remote port number for this TCP - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 61
group Implementation of the EGP group is mandatory for all systems that implement the EGP. NOTE: HP does not support the EGP Group; this section is not applicable. See the RFC1213 for complete information regarding integer value corresponding to the symbol. Fabric OS 5.x MIB reference guide 61 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 62
next are zero-valued in those SNMP implementations that are optimized to support only those functions specific to either a management agent or a management were passed from the SNMP protocol entity to the transport service. snmpInBadVersions OID Description 1.3.6.1.2.1.11.3 The total number of - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 63
.15 Mandatory The total number of SNMP Get-Request PDUs that have been accepted and processed by the SNMP protocol entity. Fabric OS 5.x MIB reference guide 63 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 64
snmpInGetNexts OID Description 1.3.6.1.2.1.11.16 The total number of been accepted and processed by the SNMP protocol entity. snmpOutTooBigs OID Description 1.3.6.1.2.1.11.20 The total number of SNMP PDUs that were generated by the SNMP protocol entity field is genErr. 64 MIB-II (RFC1213-MIB) - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 65
be disabled. Possible values are enabled (1) or disabled (2). Note This object is stored in nonvolatile memory so that it remains constant between reinitializations of the switch. This value can be changed with the agtCfgSet command. Fabric OS 5.x MIB reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 66
66 MIB-II (RFC1213-MIB) - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 67
: • FE MIB overview next • FIBRE-CHANNEL-FE-MIB (MIB-II branch), page 67 • FCFABRIC-ELEMENT-MIB (experimental branch), page 90 FE MIB overview HP supports two versions of the FE MIB: • FIBRE-CHANNEL-FE-MIB (RFC2837) in the MIB-II branch. • FCFABRIC-ELEMENT-MIB in the experimental branch. The - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 68
(1) - fcFeStatus (2) - fcFeError (3) - fcFeAccounting (4) - fcFeCapabilities (5) - fcFeMIBConformance (2) - fcFeMIBCompliances (1) - fcFeMIBGroups (2) Figure 16 fcFeMIB hierarchy - fcFeConfig (1.3.6.1.2.1.75.1.1) - fcFeFabricName (1) - fcFeElementName (2) - fcFeModuleCapacity (3) - fcFeModuleTable - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 69
(4) - fcFxPortInvalidTxWords (5) - fcFxPortInvalidCrcs (6) - fcFxPortDelimiterErrors (7) - fcFxPortAddressIdErrors (8) - fcFxPortLinkResetIns (9) - fcFxPortLinkResetOuts (10) - fcFxPortOlsIns (11) - fcFxPortOlsOuts (12) Figure 19 fcFeError hierarchy Fabric OS 5.x MIB reference guide 69 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 70
(1) - fcFxPortC3InFrames (1) - fcFxPortC3OutFrames (2) - fcFxPortC3InOctets (3) - fcFxPortC3OutOctets (4) - fcFxPortC3Discards (5) Figure 20 fcFeAccounting hierarchy - fcFeCapabilities (1.3.6.1.2.1.75.1.5) - fcFxPortCapTable (1) - fcFxPortCapEntry (1) - fcFxPortCapFcphVersionHigh - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 71
extended) 3 (locally assigned) 4 (32-bit IP address) The name identifier of a fabric. Each fabric provides a unique fabric name. Valid formats include: IEEE 48 Local The name identifier associated with a port. Valid formats include: IEEE 48 IEEE extended Local Fabric OS 5.x MIB reference guide 71 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 72
8 (half) 532 Mbaud (50.0 MB/s) 16 (full)1 Gbaud (100 MB/s) 32 (double) 2 Gbaud (200 MB/s) 64 (quadruple) 4 Gbaud (400 MB/s) Integer from 0 to 127 bit 0 (other) bit 1 (one-eighth) bit 2 (quarter) bit 3 (half) bit 4 (full) bit 5 (double) bit 6 (quadruple) bit 7 (Reserved for future) Integer from - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 73
the Brocade 4Gb SAN Switch for HP p-Class BladeSystem, the value is 12. For the 4/8 SAN Switch, 4/16 SAN Switch, SAN Switch 2/16, and SAN Switch 2/16V, the value is 16. For the SAN Switch 2/32 and SAN Switch 4/32, the value is 32. For the Core Switch 2/64, the value is 64. For the SAN Director 2/128 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 74
and service parameters of the FE and the Fx_Ports. The group represents a set of parameters associated with the FE or an Fx_Port to support its FE, regardless of their current state. Note The valid value for all HP StorageWorks switches is 1. fc FE module table This table contains one entry for - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 75
the SAN Switch 2/8-EL and SAN Switch 2/8V • 12 for the Brocade 4Gb SAN Switch for HP p-Class BladeSystem • 16 for the 4/8 SAN Switch, 4/16 SAN Switch, SAN Switch 2/16, and SAN Switch 2/16V • 32 for the SAN Switch 2/32 and SAN Switch 4/32 • 64 for the Core Switch 2/64 • 128 for the SAN Director 2/128 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 76
value is the WWN of the switch. Fx_Port table This table contains is the WWN of the port. Fx_Port common service parameters fcFxPortFcphVersionHigh OID 1.3.6.1.2.1.75.1.1.5.1.3 Description The highest or the Fx_Port is configured to support. fcFxPortFcphVersionLow OID 1.3.6.1.2.1.75.1.1.5.1.4 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 77
class service parameters fcFxPortCosSupported OID 1.3.6.1.2.1.75.1.1.5.1.9 Description A value indicating the set of Classes of Service supported by A value indicating the mode of Stacked Connect supported by the Fx_Port. fcFxPortClass2SeqDeliv OID 1.3.6.1.2.1.75.1.1.5.1.12 Description - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 78
it is unable to deliver the frame. The value 0 means that the Fx_Port does not support this parameter. fcFeStatus group This group consists of tables that contain operational status and established service parameters for the FE and the attached Nx_Ports. Fx_Port status table This table contains the - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 79
accessible by the FE, fcFxPortPhysAdminStatus is then changed to either the online (1) or testing (3) states or remains in the offline state (2). Fabric OS 5.x MIB reference guide 79 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 80
-write (which is incorrect). Fx_Port fabric login table This table contains one entry for each Fx_Port in the FE and the service parameters that have been established from the most recent fabric login, whether implicit or explicit. fcFxloginTable OID 1.3.6.1.2.1.75.1.2.3 Description A table - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 81
is a number of bytes in the range 128 to 2112, inclusive. fcFxPortCosSuppAgreed OID 1.3.6.1.2.1.75.1.2.3.1.5 Description Indicates that the attached Nx_Port has requested the Fx_Port for the support of classes of services and the Fx_Port has granted the request. fcFxPortIntermixSuppAgreed - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 82
fcFxPortClass2SeqDelivAgreed OID 1.3.6.1.2.1.75.1.2.3.1.8 Description Indicates whether the Fx_Port has agreed to support Class 2 sequential delivery from the fabric login. This is meaningful only if Class 2 service has been agreed to. Possible values are: • yes (1): The Fx_Port has agreed to - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 83
errors detected by the Fx_Port. fcFxPortInvalidCrcs OID Description 1.3.6.1.2.1.75.1.3.1.1.6 The number of invalid cyclic redundancy checks (CRCs) detected by this Fx_Port. Fabric OS 5.x MIB reference guide 83 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 84
OID Description 1.3.6.1.2.1.75.1.3.1.1.12 The number of Offline Sequence issued by this Fx_Port. feFcAccounting group The Accounting group is supported only in Fabric OS 4.x. The Accounting group consists of the following tables: • Class 1 accounting table • Class 2 accounting table • Class - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 85
1.3.6.1.2.1.75.1.4.1.1.8 Description The number of Class 1 connections successfully established in which the attached Nx_Port is the source of the connect-request. Fabric OS 5.x MIB reference guide 85 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 86
fcFxPortC1OutConnections OID 1.3.6.1.2.1.75.1.4.1.1.9 Description The number of Class 1 connections successfully established in which the attached Nx_Port is the destination of the connect-request. fcFxPortC1ConnTime OID 1.3.6.1.2.1.75.1.4.1.1.10 Description The cumulative time that this - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 87
OID 1.3.6.1.2.1.75.1.4.3.1.4 Description The number of Class 3 frame octets, including the frame delimiters, delivered through this Fx_Port to its attached Nx_Port. Fabric OS 5.x MIB reference guide 87 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 88
by this Fx_Port. fcFeCapability group This group consists of a table describing information about what each Fx_Port is inherently capable of operating or supporting. A capability might be used as expressed in its respective object value in the Configuration group. Implementation of this group is - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 89
Classes of Service that the Fx_Port is capable of supporting. fcFxPortCapIntermix valid only if the port is capable of supporting Class 1 service. Possible values are yes (1) and no Fx_Port is capable of supporting Class 2 Sequential the Fx_Port is capable of supporting Class 3 Sequential Delivery. - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 90
• fcFeConfig group, page 96 • fcFeOp group, page 101 • fcFeError group, page 106 • fcFeAcct group, page 108 • fcFeCap group, page 108 NOTE: HP does not support the settable Write function for any of the Fibre Channel FE MIB objects except fcFxPortPhysAdminStatus. The descriptions of each of the MIB - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 91
(10) - fcFxPortIntermixSupported (11) - fcFxPortStackedConnMode (12) - fcFxPortClass2SeqDeliv (13) - fcFxPortClass3SeqDeliv (14) - fcFxPortHoldTime (15) - fcFxPortBaudRate (16) - fcFxPortMedium (17) - fcFxPortTxType (18) - fcFxPortDistance (19) Figure 23 fcFeConfig hierarchy Fabric OS 5.x MIB - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 92
- fcFeOp (1.3.6.1.3.42.2.1.2) - fcFxPortOperTable (1) - fcFxPortOperEntry (1) - fcFxPortOperModuleIndex (1) - fcFxPortOperFxPortIndex (2) - fcFxPortID (3) - fcFPortAttachedPortName (4) - fcFPortConnectedPort (5) - fcFxPortBbCreditAvailable (6) - fcFxPortOperMode (7) - fcFxPortAdminMode (8) - - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 93
- fcFeAcct (1.3.6.1.3.42.2.1.4) (-- Not Supported --) Figure 26 fcFeAcct hierarchy - fcFeCap (1.3.6.1.3.42.2.1.5) - fcFxPortCapTable 13) - fcFxPortCapHoldTimeMax (14) - fcFxPortCapHoldTimeMin (15) - fcFxPortCapBaudRates (16) - fcFxPortCapMedia (17) Figure 27 fcFeCap hierarchy Definitions for FCFABRIC - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 94
of character codes 0-127 (decimal). • The graphic characters (32-126) are interpreted as U.S. ASCII. • NUL, LF, CR value up to 60 bits wide, occupying the remaining -bit address) 2 (IEEE extended) 3 (Locally assigned) 4 (32-bit -bit value unique within the address space of a fabric Integer from 128 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 95
bit 8 (long video (lv)) bits 9-15 (reserved for future use) 1 (unknown) 2 (sm) 4 (m5) 8 (m6) 16 (tv) 32 (mi) 64 (stp) 128 (tw) 256 (lv) 1 (unknown) 2 (longWaveLaser (LL)) 3 (shortWaveLaser (SL)) 4 (longWaveLED (LE)) 5 (electrical (EL)) 6 (shortWaveLaser-noOFC (SN)) Fabric OS 5.x MIB reference guide - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 96
It contains the configuration and service parameters of the FE and switch. fcFeModuleCapacity OID 1.3.6.1.3.42.2.1.1.3 Description The maximum number of modules in the FE, regardless of their current state. Note The Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director do not support - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 97
subtree 1.3.6.1.4.1.99649, and had assigned the identifier 1.3.6.1.4.1.99649.3.9 to its FeFiFo-16 PlugInCard. Note See "sysObjectID" on page 41. fcFeModuleOperStatus OID 1.3.6.1.3.42 under testing. • faulty (4): The module is defective in some way. Fabric OS 5.x MIB reference guide 97 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 98
of the module. The return value is the WWN of the switch. Fx_Port configuration table This table contains the configuration parameters of the fcFxConfTable OID Description 1.3.6.1.3.42.2.1.1.5 A table that contains configuration and service parameters of the Fx_Ports, one entry for each Fx_Port in - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 99
recent version of FC-PH that the Fx_Port is configured to support. fcFxPortFcphVersionLow OID 1.3.6.1.3.42.2.1.1.5.1.5 Description The lowest or earliest version of 10 Description A value indicating the set of Classes of Service supported by the Fx_Port. Fabric OS 5.x MIB reference guide 99 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 100
The value 0 means that the Fx_Port does not support this parameter. fcFxPortBaudRate OID Description Note 1.3.6.1.3.42.2.1.1.5.1.16 The FC-0 baud rate of the Fx_Port. The Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director do not support this MIB variable. fcFxPortMedium OID Description - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 101
Fx_Port transmitter. fcFeOp group This group consists of tables that contain operational status and established service parameters for the FE and the attached Nx_Ports. NOTE: Implementation of this group is to its attached Nx_Ports during fabric login. Fabric OS 5.x MIB reference guide 101 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 102
fcFPortAttachedPortName OID 1.3.6.1.3.42.2.1.2.1.1.4 Description The port name of the attached N_Port, if applicable. If the value of this object is '0000000000000000'H, this Fx_Port has no Nx_Port attached to it. This variable has been deprecated and might be implemented for backward - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 103
entered its current operational status. A value of 0 indicates that the Fx_Port's operational status has not changed since the agent last restarted. Fabric OS 5.x MIB reference guide 103 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 104
login table This table contains one entry for each Fx_Port in the FE, and the Service Parameters that have been established from the most recent fabric login, whether implicit or Description The version of FC-PH that the Fx_Port has agreed to support from the fabric login. 104 FE MIB objects - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 105
128 to 2112, inclusive. fcFxPortCosSuppAgreed OID 1.3.6.1.3.42.2.1.2.4.1.7 Description Indicates that the attached Nx_Port has requested the Fx_Port for the support of classes of services to support Class 3 sequential delivery from the fabric login. This is meaningful only if Class 3 service has - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 106
fcFxPortNxPortName OID 1.3.6.1.3.42.2.1.2.4.1.12 Description The port name of the attached Nx_Port, if applicable. If the value of this object is '0000000000000000'H, this Fx_Port has no Nx_Port attached to it. fcFxPortConnectedNxPort OID 1.3.6.1.3.42.2.1.2.4.1.13 Description The address - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 107
Delimiter errors detected by this Fx_Port. fcFxPortAddressIdErrors OID 1.3.6.1.3.42.2.1.3.1.1.10 Description The number of address identifier errors detected by this Fx_Port. Fabric OS 5.x MIB reference guide 107 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 108
Fx_Port. fcFxPortOlsOuts OID Description 1.3.6.1.3.42.2.1.3.1.1.14 The number of Offline Sequence errors issued by this Fx_Port. fcFeAcct group HP does not support Accounting tables; this section is not applicable. fcFeCap group This group consists of a table describing information about what - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 109
version of FC-PH that the Fx_Port is capable of supporting. fcFxPortCapFcphVersionLow OID 1.3.6.1.3.42.2.1.5.1.1.4 Description The lowest or earliest 42.2.1.5.1.1.9 A value indicating the set of Classes of Service that the Fx_Port is capable of supporting. Fabric OS 5.x MIB reference guide 109 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 110
This flag is valid only if the port is capable of supporting Class 1 service. Possible values are yes (1) or no (2). fcFxPortCapStackedConnMode OID 1.3.6.1.3.42 that the Fx_Port is capable of supporting. fcFxPortCapBaudRates OID 1.3.6.1.3.42.2.1.5.1.1.16 Description A value indicating the - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 111
• Entity MIB objects, page 115 • Entity MIB trap, page 128 • Entity MIB conformance information, page 129 Entity MIB overview Entity MIB is the module for representing multiple logical entities supported by a single SNMP agent. This MIB is supported only in Fabric OS 4.x. The descriptions of each of - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 112
(13) - entPhysicalAlias (14) - entPhysicalAssetID (15) - entPhysicalIsFRU (16) Figure 29 entityPhysical hierarchy - entityLogical (1.3.6.1.2.1.47.1.2) - entLogicalTable (1) hierarchy - entityGeneral (1.3.6.1.2.1.47.1.4) - entLastChangeTime (1) Figure 32 entityGeneral hierarchy 112 Entity MIB objects - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 113
-CONVENTION AutonomousType RowPointer TimeStamp TruthValue MODULE-COMPLIANCE OBJECT-GROUP NOTIFICATION-GROUP SnmpAdminString SNMPv2-SMI SNMPv2-TC SNMPv2-CONF SNMP-FRAMEWORK-MIB Fabric OS 5.x MIB reference guide 113 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 114
The physical entity class that is known but does not match any of the supported values. The physical entity class that is unknown to the agent. The physical and forwarding networking traffic, such as a shared backplane in a modular Ethernet switch. Note that an agent might model a backplane as a - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 115
entity (that is, SNMPv3 not supported). Syntax OCTET STRING (SIZE(0..32)) Empty string or SnmpEngineID Entity MIB HP is the chassis; in Fabric OS 4.4 and later it is marked as a FRU. Table 10 shows the entPhysical table entries for HP StorageWorks switches. Fabric OS 5.x MIB reference guide - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 116
1 PS not a FRU 2 PS not a FRU 2 PS SAN Switch 4/32 1 3 FRUs 2 PS Core Switch 2/64 10 blades 3 fans 4 PS SAN Director 2/128 10 blades 3 fans 4 PS 4/256 SAN Director 10 blades 3 fans 4 PS Brocade 4Gb SAN Switch for HP p-Class BladeSystem N/A N/A N/A WWN card 1 WWN unit not a FRU - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 117
physical entity or if the value is unknown by this agent, the value { 0, 0 } is returned. Note Currently, NULL OID { 0, 0 } is returned. Fabric OS 5.x MIB reference guide 117 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 118
then the value unknown(2) is returned. The Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director can have the following hierarchy of physical objects , four entries for power supplies, and three entries for fans SAN Switch 2/32 can have the following hierarchy of physical objects: • Chassis: - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 119
same in the event that the console interface does not distinguish between them (for example, slot-1 and the card in slot-1). Fabric OS 5.x MIB reference guide 119 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 120
(for example, binary) format, then the agent must convert such information to a printable format, in an implementation-specific manner. If no specific firmware programs are associated with the physical component, or if this information is unknown to the agent, then this object will contain a zero - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 121
to the agent, then this object contains a zero-length string. Note Set to serial number and part number (if available) respectively. Fabric OS 5.x MIB reference guide 121 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 122
physical component, then this object contains a zero-length string. Set to empty string. entPhysicalIsFRU OID Status Description Note 1.3.6.1.2.1.47.1.1.1.1.16 Current The entPhysicalIsFRU object indicates whether this physical entity is considered a FRU by the vendor. If this object contains the - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 123
the node in the SMI's naming hierarchy that represents the major MIB module, or the majority of the MIB modules, supported by the logical entity. For example: • A logical entity of a regular host/router -> mib-2 • A identified, the value mib-2 should be used. Fabric OS 5.x MIB reference guide 123 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 124
this object or might continue to return a community string (for example, tri-lingual agent support). entLogicalTAddress OID Description 1.3.6.1.2.1.47.1.2.1.1.5 The transport service address by which the logical entity receives network management traffic, formatted according to the corresponding - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 125
appropriate. Also, in the case of a single backplane repeater, a mapping for the backplane to the single repeater entity is not necessary. Fabric OS 5.x MIB reference guide 125 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 126
entLPMappingEntry OID Description Index 1.3.6.1.2.1.47.1.3.1.1 Information about an association of a logical entity to physical equipment. Note that the nature of the association is not specifically identified in this entry. It is expected that sufficient information exists in the MIBs used to - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 127
, which cannot be represented in the entPhysicalTable virtual containment tree. entPhysicalContainsEntry OID 1.3.6.1.2.1.47.1.3.3.1 Description A single container/containee relationship. Index entPhysicalIndex entPhysicalChildIndex Fabric OS 5.x MIB reference guide 127 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 128
away. An NMS should periodically check the value of entLastChangeTime to detect any missed entConfigChange notification events: for example, due to throttling or transmission loss. 128 Entity MIB objects - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 129
for all agents; however, implementation of the entityLogicalGroup or entityLogical2Group is required to support this table. entPhysicalSerialNum Not-accessible Read and write access is not required for agents of the entPhysicalIsFRU object is equal to false(2). Fabric OS 5.x MIB reference guide 129 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 130
Object Access Description entPhysicalAlias Read-only Write access is required only if the associated entPhysicalClass value is equal to chassis(3). Object Access Description entPhysicalAssetID Not-accessible Read and write access is not required for agents that cannot provide nonvolatile storage - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 131
Description The collection of objects used to represent the list of logical entities, for which a single SNMP entity provides management information. Fabric OS 5.x MIB reference guide 131 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 132
132 Entity MIB objects - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 133
and other information specific to FC Switch MIB (SW-MIB) object types. watch group, page 168 • End device group, page 177 • Switch group, page 178 • ASIC performance monitoring group, page 180 • the FC Switch MIB. The notes that follow the descriptions typically pertain to HP-specific information. - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 134
- iso (1) - org (3) - dod (6) - internet (1) - private (4) - enterprises (1) - bsci (1588) - commDev (2) - fibreChannel (1) - fcSwitch (1) - sw (1) - swTrapsV2 (0) - swSystem (1) - swFabric (2) - swModule (3) - swAgtCfg (4) - swFCport (6) - swNs (7) - swEvent (8) - swFwSystem (10) - swEndDevice (21) - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 135
14) - swFlashDLFile (15) - swFlashDLPassword (16) - swBeaconOperStatus (18) - swBeaconAdmStatus (19) - swDiagResult (20) - swNumSensors (21) - swSensorTable ( (6) - swFabricMemType (7) - swFabricMemShortVersion (8) - swIDIDMode (11) Figure 39 swFabric hierarchy Fabric OS 5.x MIB reference guide 135 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 136
(12) - swFCPortTxFrames (13) - swFCPortRxFrames (14) - swFCPortRxC2Frames (15) - swFCPortRxC3Frames (16) - swFCPortRxLCs (17) - swFCPortRxMcasts (18) - swFCPortTooManyRdys (19) - swFCPortNoTxCredits (20) - swFCPortRxEncInFrs (21) - swFCPortRxCrcs (22) - swFCPortRxTruncs (23) - swFCPortRxTooLongs (24 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 137
- swEvent (1.3.6.1.4.1.1588.2.1.1.1.8) - swEventTrapLevel (1) - swEventNumEntries (4) - swEventTable (5) - swEventEntry (1) - swEventIndex (1) - swEventTimeInfo (2) - swEventLevel (3) - swEventRepeatCount (4) - swEventDescr (5) Figure 44 swEvent hierarchy Fabric OS 5.x MIB reference guide 137 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 138
(12) - swFwThLevel (13) - swFwWriteActVals (14) - swFwDefaultChangedActs (15) - swFwDefaultExceededActs (16) - swFwDefaultBelowActs (17) - swFwDefaultAboveActs (18) - swFwDefaultInBetweenActs (19) - swFwCustChangedActs (20) - swFwCustExceededActs (21) - swFwCustBelowActs (22) - swFwCustAboveActs (23 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 139
(2) - swTrunkGrpTx (3) - swTrunkGrpRx (4) Figure 49 swTrunk hierarchy Text conventions for SW-MIB The conventions in Table 11 are used for SW-MIB. Fabric OS 5.x MIB reference guide 139 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 140
port, starting from 1 up to the maximum number of ports on the HP StorageWorks switch. Integer32 Index of the trunk master, starting from 1 up to the maximum number of trunk groups on the HP StorageWorks switch. Integer Valid action matrix: 0swFwNoAction - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 141
canceling values or action matrix changes: 1swFwCancelWrite 2swFwApplyWrite Timebase for thresholds: 1swFwTbNone 2swFwTbSec 3swFwTbMin 4swFwTbHour 5swFwTbDay Status for thresholds: 1disabled 2enabled Fabric OS 5.x MIB reference guide 141 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 142
During boot, if diagnostics fail How to configure N.A. Obsolete Port changes state Switch event Threshold reached Login/logout N.A. Always on See the HP StorageWorks Fabric OS 5.x command reference guide and the snmpConfig command help page for more information. Fabric OS Command: fwConfigure - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 143
diagnostics detect a fault with the switch. Sample Diagnostics: #TYPE #SUMMARY #ARGUMENTS #SEVERITY #TIMEINDEX #STATE Switch is faulty. Faulty reason: %d 1 Operational 3 1.3.6.1.4.1.1588.2.1.1.1.0.3 sw swFCPortOpStatus, swFCPortIndex, swFCPortName, swSsn Fabric OS 5.x MIB reference guide 143 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 144
generated when an event occurs with a level that is at or below swEventTrapLevel. #TYPE #SUMMARY #ARGUMENTS #SEVERITY #TIMEINDEX #STATE A firmware event has been logged. Event %d: %s (severity level %d) - %s SSN is #%s. 0, 1, 2, 4, 5 Informational 1 Operational Note 144 SW MIB objects Each Trap - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 145
generated event %d with %d on %s. This event is %d and SSN is #%s. 2, 0, 1, 6, 4, 5, 7, 8 Warning 1 Operational See the HP StorageWorks Fabric OS 5.x Fabric Watch administrator guide for information on setting thresholds in Fabric Watch. Sample trap output for Fabric OS 4.4.0: swFwClassAreaIndex - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 146
trap: • Logout • Unsuccessful login • Successful login • Switch configuration changes • Track changes on and off Sample trap = minute ss = seconds yyyy = year Example: Thu Aug 17 15:16:09 2000 swBootDate OID Description Note 1.3.6.1.4.1.1588.2.1.1.1.1.2 The date and time when the system last - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 147
= seconds yyyy = year Example: Thu Aug 17 15:16:09 2000 1.3.6.1.4.1.1588.2.1.1.1.1.3 The date and time when the firmware was last loaded to the switch. The return string is displayed with the following format: ddd yyyy = year Example: Thu Aug 17 15:16:09 2000 Fabric OS 5.x MIB reference guide 147 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 148
17 15:16:09 2000 swFirmwareVersion OID Description Note 1.3.6.1.4.1.1588.2.1.1.1.1.6 The current version of the firmware. The switch. Possible values are: • online (1): The switch is accessible by an external Fibre Channel port. • offline (2): The switch is not accessible. • testing (3): The switch - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 149
are not applicable. For the SAN Switch 4/32, the testing (3), faulty (4), and switchReboot (7) values are not applicable. The switchReboot (7) value applies only to the Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director. swTelnetShellAdmStatus Note Applicable to HP Fabric OS 2.x and - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 150
(5): The firmware in the flash is corrupted. This value is for informational purposes only; however, setting swFlashDLAdmStatus to this value is not allowed. Note For more information about the configDownload and configUpload commands, see the HP StorageWorks Fabric OS 5.x command reference guide - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 151
20 Description The result of the POST diagnostics. Possible values are: • sw-ok (1): The switch is okay. • sw-faulty (2): The switch switch. Note For example, the SAN Switch 2/16 value is between 1 and 13 (temperature = 6, fan = 3, power supply = 4). The value might vary depending on the switch - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 152
Switch 2/8V SAN Switch 2/16 4 sensors 3 sensors 2 absent 3 fans 4 fans 2 absent SAN Switch 2/16V 4 sensors SAN Switch 2/32 5 sensors SAN Switch 4/32 5 sensors Core Switch 2/64 10 sensors SAN Director 2/128 10 sensors 4/256 SAN Director 10 sensors Brocade 4Gb SAN Switch for 2 temp HP - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 153
for example, Temp 3 or Fan 6. Return values for the Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director depend upon the configuration of your system. swTrackChangesInfo OID 1.3.6.1.4.1.1588 task [name of task] • Track-changes on • Track-changes off Fabric OS 5.x MIB reference guide 153 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 154
The IP address of the FC interface of this logical switch. swFCIPMask Not supported in Fabric OS 3.2.0. OID 1.3.6.1.4.1.1588.2.1.1.1.1.28 Description The IP mask of the FC interface of this logical switch. swFabric group swDomainID OID 1.3.6.1.4.1.1588.2.1.1.1.2.1 Description The current - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 155
immediate neighborhood of the switch. swNbEntry OID Description the local switch +1. The valid values for the Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director are 1 of the remote switch, plus 1. The valid values for the Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director are 0 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 156
(8): 532 Mbaud • full (16): 1 Gbaud • double (32): 2 Gbaud • quadruple (64): 4 Gbaud The valid values for the Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director switch are 16 (full) and 32 (double). The valid value for the SAN Switch 4/32 is 64 (quadruple). swNbIslState OID Description - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 157
OID 1.3.6.1.4.1.1588.2.1.1.1.2.10.1.8 Description This object identifies the Fabric OS version of the member switch. Note Provides the short version of the Fabric OS version number. For example, ID (IDID) mode. Status indicating whether IDID mode is enabled. Fabric OS 5.x MIB reference guide 157 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 158
community strings can be modified only on the primary switch. swAgtCmtyEntry OID Description Index 1.3.6.1.4.1.1588.2.1.1.1.4.11.1 An swAgtCmtyStr OID Description Note 1.3.6.1.4.1.1588.2.1.1.1.4.11.1.2 This is a community string supported by the agent. If a new value is set successfully, it - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 159
for the SAN Switch 2/8-EL and SAN Switch 2/8V • 12 for Brocade 4Gb SAN Switch for HP p-Class BladeSystem • 16 for the 4/8 SAN Switch, 4/16 SAN Switch, SAN Switch 2/16, and SAN Switch 2/16V • 32 for the SAN Switch 2/32 and SAN Switch 4/32 • 64 for the Core Switch 2/64 • 128 for the SAN Director 2/128 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 160
(3): HP StorageWorks 1 GB switches • bloom (4): SAN Switch 2/8V, SAN Switch 2/16V, SAN Switch 2/32, Core Switch 2/64, and SAN Director 2/128 • rdbloom (5) • wormhole (6) • unknown (7): 4/8 SAN Switch, 4/16 SAN Switch, SAN Switch 4/32, 4/256 SAN Director, and Brocade 4Gb SAN Switch for HP p-Class - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 161
either explicit management action or per configuration information accessible by the switch, swFCPortAdmStatus is then changed to either the 1 (online) OS 4.x: The 3 (testing) state is not supported. swFCPortLinkState OID Description Note swFCPortTxType OID Description 1.3.6.1.4.1.1588 guide 161 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 162
frames that the port has received. swFCPortRxC3Frames OID 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.16 Description Counts the number of Class 3 frames that the RDYs exceed the frames received. swFCPortNoTxCredits OID 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.20 Description Counts the number of times that the - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 163
OID Description 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.31 Counts the number of loop initializations that have been initiated by the loop devices that are attached. Fabric OS 5.x MIB reference guide 163 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 164
/sec. 4 Gbit/sec is applicable only to the SAN Switch 4/32. swFCPortName Supported in Fabric OS 4.1.x and later. OID 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.36 for directors, such as 4/256 SAN Director: swFCPortSpecifier.64 = 4/15 Example for non-bladed systems, such as SAN Switch 4/32: swFCPortSpecifier - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 165
1588.2.1.1.1.7.2.1.5 The contents of a symbolic name of the port entry. In FC-GS-2, a symbolic name consists of a byte array of 1 through 256 bytes, where the first byte of the array specifies the length of its contents. This object variable corresponds to the contents of the symbolic name, with the - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 166
In FC-GS-2, a Symbolic Name consists of a byte array of 1 through 256 bytes, where the first byte of the array specifies the length of its contents. This object variable class of services supported by the port. swNsFc4 OID Description 1.3.6.1.4.1.1588.2.1.1.1.7.2.1.11 The FC-4s supported by the - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 167
the event table. (3.0 only) The value ranges from 0 to 64. (4.0 only) The value ranges from 0 to 255. (4.2 supported. Fabric OS 4.4.0 does not have Panic or Debug level messages. All messages are documented in the HP StorageWorks Fabric OS 5.x diagnostics and system error messages reference guide - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 168
Example: (HP Fabric OS 3.0 only) Aug 17 15:16:09 HP StorageWorks Fabric OS 5.x diagnostics and system error messages reference guide. Fabric watch group The Fabric Watch group contains one license scalar and two tables. • The scalar, swFwFabricWatchLicense, is used to tell is whether the switch - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 169
1.3.6.1.4.1.1588.2.1.1.1.10.1 Description If the license key is installed on the switch for Fabric Watch, the return value is swFwLicensed; otherwise, the value example: • C = environment (class), temperature (area). • RPM = environment (class), fan (area). Fabric OS 5.x MIB reference guide 169 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 170
swFwDefaultTimebase OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.4 Description A default polling period for the Fabric Watch classArea combination. For example: • swFwTbMin = port (class), link loss (area). • swFwTbNone = environment (class), temperature (area). swFwDefaultLow OID Description - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 171
can be removed by setting this variable to swFwCancelWrite. swFwDefaultChangedActs OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.15 Description Default action matrix for changed event. Fabric OS 5.x MIB reference guide 171 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 172
swFwDefaultExceededActs OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.16 Description Default action matrix for an exceeded event. The exceeded for an in-between event. swFwCustChangedActs OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.20 Description Custom action matrix for a changed event. swFwCustExceededActs - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 173
.2.1.1.1.10.3 Description The table of individual thresholds. swFwThresholdEntry OID Description Index 1.3.6.1.4.1.1588.2.1.1.1.10.3.1 An entry of an individual threshold. swFwClassAreaIndex, swFwThresholdIndex Fabric OS 5.x MIB reference guide 173 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 174
of 12 • eportLink012: index of 13 • eportLink013: index of 14 • eportLink014: index of 15 • eportLink015: index of 16 swFwStatus OID Description 1.3.6.1.4.1.1588.2.1.1.1.10.3.1.2 Indicates whether a threshold is enabled or disabled. swFwName OID 1.3.6.1.4.1.1588.2.1.1.1.10.3.1.3 Description - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 175
CRCs 0 Port Link Failures 0 Port Protocol Errors 0 Port RX Performance 0 Port Loss of Signal 0 Port State Changes 0 Port Loss of Sync 0 Fabric OS 5.x MIB reference guide 175 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 176
Table 14 swFwName objects and object types (continued) swFwName objects (swFwName) Object types (threshold names) (continued) portTXPerf000 portWords000 fopportCRCs013 fopportLink013 fopportProtoErr0 fopportRXPerf013 fopportSignal013 fopportState013 fopportSync013 fopportTXPerf013 fopportWords013 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 177
Description An entry of an individual end device's RLS. Index swEndDevicePort, swEndDeviceAlpa Note Since HP StorageWorks switches start with port # 0, the SNMP port # should be the physical port # For example, SNMP AL_PA number 0xf0 translates to 0xef. Fabric OS 5.x MIB reference guide 177 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 178
count for the end device. swEndDeviceInvalidCRC OID 1.3.6.1.4.1.1588.2.1.1.1.21.1.1.9 Description Invalid CRC count for the end device. Switch group Not supported. swGroupTable OID 1.3.6.1.4.1.1588.2.1.1.1.22.1 Description The table of groups. This might not be available on all versions - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 179
identifies the Group ID of the member switch. swGroupMemWwn OID Description 1.3.6.1.4.1.1588.2.1.1.1.22.2.1.2 This switch. swGroupMemPos OID Description 1.3.6.1.4.1.1588.2.1.1.1.22.2.1.3 This object identifies the position of the member switch in the group, based on the order that the switches - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 180
occurred on the frames destined to each possible AL_PA attached to a specific port. Note For the SAN Switch 4/32, this value is always 0. CRC counters are not supported on this platform. swBlmPerfEEMntTable OID 1.3.6.1.4.1.1588.2.1.1.1.23.2 Description End-to-end monitoring counter table. 180 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 181
1588.2.1.1.1.23.2.1.1 This object identifies the port number of the switch. swBlmPerfEERefKey OID Description 1.3.6.1.4.1.1588.2.1.1.1.23.2.1.2 This object identifies the OID 1.3.6.1.4.1.1588.2.1.1.1.23.3 Description Filter-based monitoring counter. Fabric OS 5.x MIB reference guide 181 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 182
.2.1.1.1.24.2 Displays trunking information for the switch. For the SAN Switch 4/32, 8 ports per trunk are supported. The SAN Switch 4/32 supports masterless trunking, or dynamic swapping of master port. See the HP StorageWorks Fabric OS 5.x administrator guide for more information on these features - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 183
trunking table. swTrunkPortIndex swTrunkPortIndex OID Description Note 1.3.6.1.4.1.1588.2.1.1.1.24.2.1.1 This object identifies the switch port index. The value of a port index is 1 higher than the port that specifies the group number to which port belongs. Fabric OS 5.x MIB reference guide 183 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 184
swTrunkGrpMaster OID Description 1.3.6.1.4.1.1588.2.1.1.1.24.3.1.2 This object gives the master port ID for the trunk group. swTrunkGrpTx OID Description Note 1.3.6.1.4.1.1588.2.1.1.1.24.3.1.3 Gives the aggregate value of the transmitted words from this trunk group. The syntax for this MIB - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 185
HA features of Fabric OS 4.x. This MIB is supported only in Fabric OS 4.1.0 and later (and is not supported in Fabric OS 3.x or Fabric OS 2.6.x). The - fibreChannel (1) - haMIB (2) - highAvailability (1) - haMIBTraps (2) Figure 50 HA-MIB overall tree structure Fabric OS 5.x MIB reference guide 185 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 186
- haMIB (1.3.6.1.4.1.1588.2.1.2) - highAvailability (1) - haStatus (1) - fruTable (5) - fruEntry (1) - fruClass (1) - fruStatus (2) - fruObjectNum (3) - fruSupplierId (4) - fruSupplierPartNum (5) - fruSupplierSerialNum (6) - fruSupplierRevCode (7) - fruHistoryTable (6) - fruHistoryEntry (1) - - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 187
HP StorageWorks Switches HP StorageWorks platform Blades Fans Power supplies WWN card SAN Switch 2/16 NA SAN Switch 2/32 NA SAN Switch 4/32 NA Core Switch 2/64 8 port blades 2 CP blades SAN Director 2/128 8 port blades 2 CP blades Brocade 4Gb SAN Switch for N/A HP reference guide 187 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 188
fruClass OID Description 1.3.6.1.4.1.1588.2.1.2.1.5.1.1 The type of the FRU object that this slot can hold. Possible values are: • other (1) • unknown (2) • chassis (3) • cp (4) • other-CP (5) • switchblade (6) • wwn (7) • powerSupply (8) • fan (9) fruStatus OID Description 1.3.6.1.4.1.1588 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 189
blade and the unit number for everything else. fruHistoryEvent OID Description 1.3.6.1.4.1.1588.2.1.2.1.6.1.4 The type of the FRU event: • added (1) • removed (2) • invalid (3) Fabric OS 5.x MIB reference guide 189 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 190
The time at which this event happened. fruHistoryPartNum OID Description 1.3.6.1.4.1.1588.2.1.2.1.6.1.6 The HP part number of the FRU object. fruHistorySerialNum OID Description 1.3.6.1.4.1.1588.2.1.2.1.6.1.7 The HP serial number of the FRU object. Control processor (CP) table cpTable OID - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 191
Current Description This trap is sent when the status of any FRU object changes. Note Some of the triggers that will generate this trap are: • switch reboot • Add or remove a FRU component Sample trap output for Fabric OS 4.4.0; The following trap is generated when - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 192
cpStatusChanged OID Objects Status Description Note fruHistoryTrap OID Objects Status Description Note 1.3.6.1.4.1.1588.2.1.2.2.0.2 cpStatus cpLastEvent swID swSsn Current This trap is sent when the status of any CP object changes. The cpLastEvent variable provides the information about the event - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 193
-MIB traps and examples of triggers HA-MIB traps fruStatusChanged cpStatusChanged Trigger Examples of events that will trigger this trap: • Switch reboot • Add or remove a FRU component Examples of events that will trigger this trap: • Reboot • firmwareDownload fruHistoryTrap Examples of events - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 194
194 High-availability MIB objects - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 195
(LINK-INCIDENT-MIB) defines support for FICON in Fabric OS 4.1.2 and later. This MIB addresses link incident and link failure data for FICON hosts and devices connected to an HP StorageWorks switch. The descriptions of each structure of the FICON MIB file system. Fabric OS 5.x MIB reference guide 195 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 196
- iso (1) - org (3) - dod (6) - internet (1) - private (4) - enterprises (1) - bsci (1588) - commDev (2) - fibreChannel (1) - fcSwitch (1) - linkIncidentMIB (50) - ficonRNID (2) - ficonLIRR(3) - ficonRLIR (4) - linkIncidentMIBTraps (21) Figure 52 Overall tree structure for FICON MIB (linkIncidentMIB - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 197
- linkIncidentMIBTraps (21) - linkIncidentMIBTrapPrefix (0) - linkRNIDDeviceRegistration (1) - linkRNIDDeviceDeRegistration (2) - linkLIRRListenerAdded (3) - linkLIRRListenerRemoved (4) - linkRLIRFailureIncident (5) Figure 54 linkIncidentMIBTraps hierarchy Fabric OS 5.x MIB reference guide 197 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 198
NOTIFICATION-TYPE TEXTUAL-CONVENTION DisplayString fcSwitch SNMPv2-SMI SNMPv2-TC HP-REG-MIB Textual conventions Table 19 lists the text conventions { fcp (1), sb2 (2) } Represents Fibre Channel Address ID, a 24-bit value unique within the address space of a fabric. OCTET STRING (SIZE (3)) - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 199
page for additional information on FICON MIB tables. nodeRNIDTable OID Description 1.3.6.1.4.1.1588.2.1.1.50.2.2 A table that contains one entry for each FICON RNID node attached to a switch. Fabric OS 5.x MIB reference guide 199 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 200
FICON node (see Table 20). Index nodeRNIDIndex nodeRNIDIndex Table 20 NodeRNIDEntry objects and object types 1.3.6.1.4.1.1588.2.1.1.50.2.2.1.4 RNID flags for an Incident port. Bits 0-2 of the flag describe the validity of bits 3-7 of the flag. Bit 3 of the flag specifies whether the node is - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 201
Node identification data format of the connected port. nodeRNIDTag OID Description 1.3.6.1.4.1.1588.2.1.1.50.2.2.1.13 Node identification tag of the connected port. Fabric OS 5.x MIB reference guide 201 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 202
port. switchRNIDTableNumEntries OID 1.3.6.1.4.1.1588.2.1.1.50.2.3 Description The number of entries in an RNID table that corresponds to the switch. Note See the ficonShow command help page for additional information on FICON MIB tables. switchRNIDTable OID Description 1.3.6.1.4.1.1588 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 203
The sequence number of the switch. switchRNIDTag OID Description 1.3.6.1.4.1.1588.2.1.1.50.2.4.1.9 The tag of the switch. switchRNIDParams OID Description 1.3.6.1.4.1.1588.2.1.1.50 command help page for additional information on FICON MIB tables. Fabric OS 5.x MIB reference guide 203 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 204
Description 1.3.6.1.4.1.1588.2.1.1.50.3.2.1.3 PID for the Listener port. LIRRRegType OID Description 1.3.6.1.4.1.1588.2.1.1.50.3.2.1.4 Registration type: conditional or unconditional. LIRRProtocol OID Description 1.3.6.1.4.1.1588.2.1.1.50.3.2.1.5 Protocol type supported. 204 FICON MIB objects - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 205
FICON. rLIRTableNumEntries OID 1.3.6.1.4.1.1588.2.1.1.50.4.1 Description The number of entries in a switch RLIR table. Note See the ficonShow command help page for additional information on FcPortID lIRRRegType RegType lIRRProtocol LIRRProtocol Fabric OS 5.x MIB reference guide 205 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 206
rLIRIndex OID Description 1.3.6.1.4.1.1588.2.1.1.50.4.2.1.1 Index into the RLIR table. rLIRIncidentPortWwn OID 1.3.6.1.4.1.1588.2.1.1.50.4.2.1.2 Description Port WWN for RLIR Incident port. rLIRIncidentNodeWwn OID 1.3.6.1.4.1.1588.2.1.1.50.4.2.1.3 Description Incident node WWN. - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 207
nodeRNIDConnectedPortWWN Description A device registered with the switch. linkRNIDDeviceDeRegistration Trap# 2 OID 1.3.6.1.4.1.1588.2.1.1.50. , nodeRNIDConnectedPortWWN Description A device deregistered from the switch. linkLIRRListenerAdded Trap# 3 OID 1.3.6.1.4.1.1588.2.1.1.50.21 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 208
linkLIRRListenerRemoved Trap# 4 OID 1.3.6.1.4.1.1588.2.1.1.50.21.0.4 Enterprise sw Variables LIRRListenerPortWWN, LIRRListenerPID, LIRRIndex Description A listener for link failure incident has been removed. linkRLIRFailureIncident Trap# 5 OID 1.3.6.1.4.1.1588.2.1.1.50.21.0.5 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 209
ConnSet group, page 216 • Statistics group, page 241 • Service group, page 250 • SNMP trap registration group, page 252 notes that follow the descriptions are typically HP-specific information. The object types in • Revision Number • Statistic Set • Service Set FCMGMT-MIB system organization of MIB - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 210
) - connUnitPrincipal (13) - connUnitNumSensors (14) - connUnitStatusChangeTime (15) - connUnitConfigurationChangeTime (16) - connUnitNumRevs (17) - connUnitNumZones (18) - connUnitModuleId (19) - connUnitName (20) - connUnitInfo (21) - connUnitControl (22) - connUnitContact (23) - connUnitLocation - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 211
- connUnitRevsTable (7) - connUnitRevsEntry (1) - connUnitRevsUnitId (1) - connUnitRevsIndex (2) - connUnitRevsRevId (3) - connUnitRevsDescription (4) Figure 57 ConnUnitRevs table hierarchy Fabric OS 5.x MIB reference guide 211 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 212
(13) - connUnitPortVendor (14) - connUnitPortSpeed (15) - connUnitPortControl (16) - connUnitPortName (17) - connUnitPortPhysicalNumber (18) - connUnitPortStatObject (19) - connUnitPortProtocolCap (20) - connUnitPortProtocolOp (21) - connUnitPortNodeWwn (22) - connUnitPortHWState (23 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 213
(11) - connUnitLinkUnitTypeY (12) - (13) - connUnitLinkCurrIndex (14) Figure 61 ConnUnitLinkTable hierarchy - trapRegTable (8) - trapRegEntry (1) - trapRegIpAddress (1) - trapRegPort (2) - trapRegFilter (3) - trapRegRowState (4) Figure 62 TrapRegTable hierarchy Fabric OS 5.x MIB reference guide 213 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 214
connUnitPortStatCountClass1FBSYFrames (16) - connUnitPortStatCountClass1PBSYFrames connUnitPortStatCountClass2RxFrames (20) - connUnitPortStatCountTxBroadcastObjects (32) - connUnitPortStatCountRxLinkResets - connUnitSnsMaxEntry (1) Figure 64 ConnUnitServiceScalars hierarchy 214 FibreAlliance - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 215
SNS table. Octet string of size 16 An optional global scope identifier for this connectivity unit. It must be a WWN for this connectivity unit or 16 octets of value zero. Octet ) Informational status • 9 (debug) Debug status • 10 (mark) All messages logged. Fabric OS 5.x MIB reference guide 215 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 216
Value Description FcUnitType Integer • 1 (unknown) • 2 (other) None of 3-14. • 3 (hub) Passive connectivity unit supporting loop protocol • 4 (switch) Active connectivity unit supporting multiple protocols • 5 (gateway) Unit that not only converts the interface but also encapsulates the frame - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 217
HP implementation maps the switch 16-octet value. Example: connUnitType.10.0.0.60.69.4.11.19.0.0.0.0.0.0.0.0 where the object instance identifier consists of 16 octets, each representing the byte value from high-byte order to low-byte order of this 128-bit integer. Fabric OS 5.x MIB reference guide - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 218
or 16 octets of value 0. The following characteristics are required: • WWN formats requiring fewer than 16 octets must be extended to 16 octets The HP implementation maps the switch WWN to the top 8 octets of this variable and sets the remaining lower 8 octets to 0. Example: If the HP switch WWN - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 219
the SAN Switch 2/8-EL and SAN Switch 2/8V • 12 for the Brocade 4Gb SAN Switch for HP p-Class BladeSystem • 16 for the 4/8 SAN Switch, 4/16 SAN Switch, SAN Switch 2/16, and SAN Switch 2/16V • 32 for the SAN Switch 2/32 and SAN Switch 4/32 • 64 for the Core Switch 2/64 • 128 for the SAN Director 2/128 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 220
has the same definition as systemURL for keywords. Same as systemURL. The expected value for connUnitURL.0 is: "http://{a.b.c.d}" where {a.b.c.d} is the IP address of the switch if Web Tools license is available and "" (null) is the IP address of the - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 221
with leading 0s if required. If this value is not applicable, return all bits to 1. Set to the switch domain ID (as per FC-SW). connUnitProxyMaster OID 1.3.6.1.3.94.1.6.1.12 Description A connUnitStatus or connUnitPortStatus changed. Note Not supported. Fabric OS 5.x MIB reference guide 221 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 222
1.3.6.1.3.94.1.6.1.16 Description The Number of zones defined in connUnitZoneTable. Not supported. connUnitModuleId OID Description Note 1.3.6.1.3.94.1.6.1.19 A module. Set to the WWN of the switch. connUnitName OID Description Note 1.3.6.1.3.94.1.6.1.20 A display string containing a name for - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 223
in an offline state, it cannot be used to perform meaningful Fibre Channel work. • onlineConnUnit (6): Enable switch. The addressed unit puts itself into an implementation-dependant online state. In general, if a unit is in . Always returns the value 9 (debug). Fabric OS 5.x MIB reference guide 223 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 224
. For Fabric OS 3.0 this value is 64. For Fabric OS 4.0 this value is 255 SAN Switch 4/32, this value is 23.1) and another entry for the Fabric OS version (for this release the value is 4.4). connUnitRevsEntry OID Description Index 1.3.6.1.3.94.1.7.1 Table of the revisions supported - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 225
table connUnitSensorTable OID 1.3.6.1.3.94.1.8 Description Table of the sensors supported by each connectivity unit managed by this agent. Note See for specific sensor counts on the various switches. connUnitSensorEntry OID 1.3.6.1.3.94.1.8.1 Description Each OS 5.x MIB reference guide 225 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 226
connUnitSensorName OID 1.3.6.1.3.94.1.8.1.3 Description A textual identification of the sensor, intended primarily for operator use. Note Each identification contains the name of sensor in textual format: for example, Temp #1, Fan #2, and so forth. connUnitSensorStatus OID 1.3.6.1.3.94 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 227
current is a keyword.) • airflow (7) • frequency (8) • power (9) • door (10) Not supported in Fabric OS 2.6.1. Note The following mapping is for each individual sensor, where applicable: swSensorType 1 a specific port. connUnitPortUnitId connUnitPortIndex Fabric OS 5.x MIB reference guide 227 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 228
the SAN Switch 2/8-EL and SAN Switch 2/8V • 12 for the Brocade 4Gb SAN Switch for HP p-Class BladeSystem • 16 for the 4/8 SAN Switch, 4/16 SAN Switch, SAN Switch 2/16, and SAN Switch 2/16V • 32 for the SAN Switch 2/32 and SAN Switch 4/32 • 64 for the Core Switch 2/64 • 128 for the SAN Director 2/128 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 229
Bit mask that specifies the Classes of Service capability of this port. If this is not applicable, return all bits set to 0. The bits Bit mask that specifies the Classes of Service that are currently operational. If this is not applicable, returns all bits your testing. (Not supported in Fabric OS - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 230
is not participating and does not have a loop address. • initializing (7): Protocol is proceeding. • bypass (8): Do not use. • ols (9): FCP offline status. (Not supported in Fabric OS 2.6.1.) For an E, F, or FL_Port, the value is 3 (ok). For a U_Port, the value is 2 (unused) if not faulty with GBIC - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 231
switch has WWN 10:00:00:60:69:10:02:18, then port numbers 0 and 6 have WWN 20:00:00:60:69:10:02:18 and 20 switch. connUnitPortFCId OID Description Note 1.3.6.1.3.94.1.10.1.11 The assigned Fibre Channel ID of this port. This value is expected to be a Big Endian value of 24 bits reference guide 231 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 232
for the Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director: 125,000 KBps, 250,000 KBps, or 500,000 KBps, depending on the configuration. connUnitPortControl OID Description 1.3.6.1.3.94.1.10.1.16 232 FibreAlliance MIB objects - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 233
8 for SAN Switch 2/8-EL and SAN Switch 2/8V • 12 for the Brocade 4Gb SAN Switch for HP p-Class BladeSystem • 16 for the 4/8 SAN Switch, 4/16 SAN Switch, SAN Switch 2/16, and SAN Switch 2/16V • 32 for SAN Switch 2/32 and SAN Switch 4/32 • 64 for the Core Switch 2/64 • 128 for SAN Director 2/128 • 256 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 234
. connUnitPortProtocolCap Not supported in Fabric OS 2.6.1. OID 1.3.6.1.3.94.1.10.1.20 Description The bit mask that specifies = TCP/IP • 16 = VI • 32 = FICON connUnitPortProtocolOp Not supported in Fabric OS 2.6.1. OID 1.3.6.1.3.94.1.10.1.21 Description The bit mask that specifies the - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 235
switch has WWN 10:00:00:60:69:10:02:18, then port number 0 and 6 have WWN 20:00:00:60:69:10:02:18 and 20 64 supported. Fabric OS 4.4.0 does not have Panic or Debug level messages. All messages are documented in the HP StorageWorks Fabric OS 5.x diagnostics and system error messages reference guide - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 236
write over previous events. This object is an index into the buffer. HP recommends that this table be read using getNext commands to retrieve the initial index is that internal event ID might represent a smaller number than a 32-bit integer (for example, maximum 100 entries) and would have a value - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 237
error (5) warning (6) info (8) debug (9) Note See FcEventSeverity in Table 24 on page 215 for more information about severity. connUnitEventType OID Description Note 1.3.6.1.3.94.1.11.1.7 The type of this connUnitPortStatus[...]. Note Always set to null. Fabric OS 5.x MIB reference guide 237 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 238
on error messages, see the HP StorageWorks Fabric OS diagnostics and system error messages reference guide. Connectivity unit link table of the methods for filling in the table would be to use the RNID ELS command (ANSI document 99-422v0). This command queries a port for the information - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 239
to WWN of the local switch. connUnitLinkIndex OID Description Note the highest value represented by the number of bits. This value is reset to 0 when Note WWN of the local switch. connUnitLinkPortNumberX OID 1.3.6.1.3.94.1.12 connUnitLinkNodeIdX, if known; otherwise, 16 octets of binary 0. Note - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 240
object must be equal to its connUnitID. Note ISL: WWN of the remote switch. Device: Node name of the device. connUnitLinkPortNumberY OID 1.3.6.1.3.94.1.12.1.7 Description for the node identified by connUnitLinkNodeIdY, if known; otherwise, 16 octets of binary 0. Note ISL: IP address (IPv4). - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 241
objects start at a value of 0 at hardware initialization and continue incrementing until end of 63 bits and then wrap to 0. The case for all Class 1 Frames; HP does not support them. connUnitPortStatTable OID 1.3.6.1.3.94.4.5 Description A list of statistics for the fabric port types. Fabric - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 242
connUnitPortStatEntry OID 1.3.6.1.3.94.4.5.1 Description An entry describing port statistics. Index connUnitPortStatUnitId connUnitPortStatIndex connUnitPortStatUnitId OID 1.3.6.1.3.94.4.5.1.1 Description The connUnitId of the connectivity unit that contains this port statistics table. - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 243
connUnitPortStatCountInputBuffersFull Not supported. OID 0 0 0 0 (Not Supported) Note This is a Fibre sum counters. connUnitPortStatCountPBSYFrames Not supported. OID 1.3.6.1.3.94.4.5.1.11 Description 80 0 0 0 0 0 0 0 (not supported) Note This is a Fibre Channel only statistic; the - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 244
The number of Class 1 Frames transmitted out this port. Note This is a Fibre Channel statistic only. HP does not support Class 1 Frames. connUnitPortStatCountClass1FBSYFrames OID 1.3.6.1.3.94.4.5.1.16 Description The number of times that FBSY was returned to this port as a result of a Class - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 245
Note This is a Fibre Channel statistic only. HP does not support Class 1 Frames. connUnitPortStatCountClass2RxFrames OID 1.3.6.1.3.94.4.5.1.20 Description The number of Class 2 Frames received at 0 0 0 0 0 0 Note This is a Fibre Channel statistic only. Fabric OS 5.x MIB reference guide 245 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 246
this port as a result of a Class 2 Frame that was rejected at the destination N_Port. Return value: 80 0 0 0 0 0 0 0 (not supported) Note This is a Fibre Channel statistic only. connUnitPortStatCountClass3RxFrames OID 1.3.6.1.3.94.4.5.1.26 Description The number of Class 3 Frames received at - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 247
Return value: 80 0 0 0 0 0 0 0 (not supported) connUnitPortStatCountTxBroadcastObjects OID 1.3.6.1.3.94.4.5.1.32 Description The number of broadcast frames or packets transmitted out from this port . Note This is a Fibre Channel statistic only. Fabric OS 5.x MIB reference guide 247 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 248
94.4.5.1.38 Description The number of offline primitive sequence received at this port. Return Value: 80 0 0 0 0 0 0 0 (not supported) Note This is a Fibre Channel statistic only. connUnitPortStatCountLinkFailures OID 1.3.6.1.3.94.4.5.1.39 Description The number of link failures. This count - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 249
. For example, when the SID or DID is not known to the routing algorithm. Note This is a Fibre Channel statistic only. Fabric OS 5.x MIB reference guide 249 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 250
a Fibre Channel statistic only. Service group Not supported in Fabric OS 2.6.1. Implementation of the Service group is mandatory for all systems. The Service group contains the following subgroups: • Connectivity Unit Service Scalers Group • Connectivity Unit Service Tables Group Connectivity unit - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 251
. connUnitSnsClassOfSvc OID 1.3.6.1.3.94.5.2.1.1.6 Description The Classes of Service offered by this entry in the SNS table. table. connUnitSnsFC4Type OID 1.3.6.1.3.94.5.2.1.1.9 Description The FC-4 types supported by this entry in the SNS table. connUnitSnsPortType OID 1.3.6.1.3. - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 252
registration group This section discusses the trapMaxClients MIBs. trapMaxClients OID 1.3.6.1.3.94.2.1 Description The maximum number of SNMP trap recipients supported by the connectivity unit. Note Set to 6. trapClientCount OID Description 1.3.6.1.3.94.2.2 The current number of rows in the - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 253
unknown (1) critical (4) error (5) warning (6) info (8) debug (9) This severity applies to all entries. See FcEventSeverity in Table 24 on page 215. The values 1, 3, 7, and 10 are not valid for SET operations. trapRegRowState OID Description 1.3.6.1.3.94.2.3.1.4 Specifies the state of the row - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 254
of 03.00. Note Set to 0300. Unsupported tables The Connectivity Unit Port Statistics Fabric Table is supported only in Fabric OS 2.6.1. HP does not support the following tables: • Connectivity Unit Port Statistics Hub Table • Connectivity Unit Port Statistics SCSI Table • Connectivity Unit - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 255
96.105.144.109.136.0.0.0.0.0.0.0.0.1 = warning(4) connUnitState.16.0.0.96.105.144.109.136.0.0.0.0.0.0.0.0.1 = offline(3) See the HP StorageWorks Fabric OS 5.x Fabric Watch administrator guide to see how the switch status is determined. connUnitDeletedTrap Enterprise fcmgmt Variables connUnitId - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 256
unit changes. Sample trap output for Fabric OS 4.4.0: connUnitSensorStatus.16.0.0.96.105.144.109.136.0.0.0.0.0.0.0.0.7 = failed(5) See the HP StorageWorks Fabric OS 5.x Fabric Watch administrator guide for information on configuring thresholds that generate these traps. connUnitPortStatusChange - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 257
function-based listing of MIB objects. To see the correlation of various switch objects to MIB objects, including the following: • Switch variables next • Sensor variables, page 257 • Port variables, page accounting table, page 86 • fcFeCapability group, page 88 Fabric OS 5.x MIB reference guide 257 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 258
Event variables MIB variables that assist in monitoring or modifying events are found in the following tables or groups: • Connectivity unit event table, page 235 • Event group, page 167 ISL and end device variables MIB variables that assist in monitoring or modifying ISL and end-devices are found - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 259
75.1.1.5.1 76 1.3.6.1.2.1.75.1.1.5.1.1 76 1.3.6.1.2.1.75.1.1.5.1.2 76 1.3.6.1.2.1.75.1.1.5.1.3 76 1.3.6.1.2.1.75.1.1.5.1.4 76 1.3.6.1.2.1.75.1.1.5.1.5 77 1.3.6.1.2.1.75.1.1.5.1.6 77 1.3.6.1.2.1.75.1.1.5.1.7 77 1.3.6.1.2.1.75.1.1.5.1.8 77 Fabric OS 5.x MIB reference guide 259 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 260
Table 27 MIB object name and OID matrix (continued) MIB Object Name OID fcFxPortCosSupported fcFxPortIntermixSupported fcFxPortStackedConnMode fcFxPortClass2SeqDeliv fcFxPortClass3SeqDeliv fcFxPortHoldTime fcFeStatus fcFxPortStatusTable fcFxPortStatusEntry fcFxPortID fcFxPortBbCreditAvailable - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 261
85 85 86 86 86 86 86 86 86 86 87 87 87 87 87 87 87 87 87 88 70 Fabric OS 5.x MIB reference guide 261 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 262
Table 27 MIB object name and OID matrix (continued) MIB Object Name OID fcFxPortCapTable fcFxPortCapEntry fcFxPortCapFcphVersionHigh fcFxPortCapFcphVersionLow fcFxPortCapBbCreditMax fcFxPortCapBbCreditMin fcFxPortCapRxDataFieldSizeMax fcFxPortCapRxDataFieldSizeMin fcFxPortCapCos - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 263
12 1.3.6.1.3.42.2.1.1.5.1.13 1.3.6.1.3.42.2.1.1.5.1.14 1.3.6.1.3.42.2.1.1.5.1.15 1.3.6.1.3.42.2.1.1.5.1.16 1.3.6.1.3.42.2.1.1.5.1.17 1.3.6.1.3.42.2.1.1.5.1.18 1.3.6.1.3.42.2.1.1.5.1.19 1.3.6.1.3.42.2.1.2 92 101 101 101 101 101 102 102 102 102 102 102 102 Fabric OS 5.x MIB reference guide 263 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 264
Table 27 MIB object name and OID matrix (continued) MIB Object Name OID fcFxPortPhysModuleIndex fcFxPortPhysFxPortIndex fcFxPortPhysAdminStatus fcFxPortPhysOperStatus fcFxPortPhysLastChange fcFxPortPhysRttov fcFxlogiTable fcFxlogiEntry fcFxlogiModuleIndex fcFxlogiFxPortIndex fcFxlogiNxPortIndex - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 265
42.2.1.5.1.1.12 1.3.6.1.3.42.2.1.5.1.1.13 1.3.6.1.3.42.2.1.5.1.1.14 1.3.6.1.3.42.2.1.5.1.1.15 1.3.6.1.3.42.2.1.5.1.1.16 1.3.6.1.3.42.2.1.5.1.1.17 1.3.6.1.3.94 1.3.6.1.3.94.1 1.3.6.1.3.94.1.1 1.3.6.1.3.94.1.2 217 217 218 219 219 219 220 220 220 220 220 221 221 Fabric OS 5.x MIB reference guide 265 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 266
connUnitPortFCClassOp 1.3.6.1.3.94.1.6.1.13 1.3.6.1.3.94.1.6.1.14 1.3.6.1.3.94.1.6.1.15 1.3.6.1.3.94.1.6.1.16 1.3.6.1.3.94.1.6.1.17 1.3.6.1.3.94.1.6.1.18 1.3.6.1.3.94.1.6.1.19 1.3.6.1.3.94.1.6.1.20 1.3.6.1.3.94.1.6.1.21 1.3.6.1.3.94.1.6.1.22 1.3.6.1.3.94.1.6.1.23 1.3.6.1.3.94.1.6.1.24 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 267
15 1.3.6.1.3.94.1.10.1.16 1.3.6.1.3.94.1.10.1.17 1.3.6.1.3.94.1.10.1.18 1.3.6.1.3.94.1.10.1.19 1.3.6.1.3.94.1.10.1.20 1.3.6.1.3.94.1.10.1.21 1.3.6.1.3.94.1.12.1.7 1.3.6.1.3.94.1.12.1.8 Page 229 230 230 230 231 231 231 231 231 232 232 233 233 234 234 234 235 235 235 236 236 236 236 237 237 237 237 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 268
94.4.5.1.10 1.3.6.1.3.94.4.5.1.11 1.3.6.1.3.94.4.5.1.12 1.3.6.1.3.94.4.5.1.13 1.3.6.1.3.94.4.5.1.14 1.3.6.1.3.94.4.5.1.15 1.3.6.1.3.94.4.5.1.16 1.3.6.1.3.94.4.5.1.17 1.3.6.1.3.94.4.5.1.18 1.3.6.1.3.94.4.5.1.19 1.3.6.1.3.94.4.5.1.20 268 MIB OIDs and their matching object names Page 240 240 240 241 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 269
94.4.5.1.28 1.3.6.1.3.94.4.5.1.29 1.3.6.1.3.94.4.5.1.30 1.3.6.1.3.94.4.5.1.31 1.3.6.1.3.94.4.5.1.32 1.3.6.1.3.94.4.5.1.33 1.3.6.1.3.94.4.5.1.34 1.3.6.1.3.94.4.5.1.35 1.3.6.1.3.94.4.5.1.36 248 248 249 249 249 249 249 249 250 250 214 214 250 215 250 250 250 251 251 Fabric OS 5.x MIB reference - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 270
11 1.3.6.1.4.1.1588.2.1.1.1.1.12 1.3.6.1.4.1.1588.2.1.1.1.1.13 1.3.6.1.4.1.1588.2.1.1.1.1.14 1.3.6.1.4.1.1588.2.1.1.1.1.15 1.3.6.1.4.1.1588.2.1.1.1.1.16 1.3.6.1.4.1.1588.2.1.1.1.1.18 1.3.6.1.4.1.1588.2.1.1.1.1.19 1.3.6.1.4.1.1588.2.1.1.1.1.20 270 MIB OIDs and their matching object names Page 251 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 271
155 156 156 156 156 136 136 158 158 158 158 158 136 159 159 159 160 160 160 160 161 Fabric OS 5.x MIB reference guide 271 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 272
16 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.17 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.18 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.19 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.20 .2.1.1.1.6.2.1.30 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.31 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.32 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.33 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.34 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 273
.2.1.13 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.14 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.15 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.16 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.17 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.18 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.19 170 170 170 171 171 171 171 172 172 172 172 Fabric OS 5.x MIB reference guide 273 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 274
swEndDeviceInvalidCRC swBlmPerfMnt swBlmPerfALPAMntTable swBlmPerfALPAMntEntry swBlmPerfAlpaPort swBlmPerfAlpaIndx swBlmPerfAlpa swBlmPerfAlpaCRCCnt 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.20 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.21 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.22 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.23 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 275
154 154 156 156 156 157 157 157 157 157 157 157 157 164 139 178 178 179 179 179 179 Fabric OS 5.x MIB reference guide 275 - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 276
Table 27 MIB object name and OID matrix (continued) MIB Object Name OID swGroupMemEntry swGroupID swGroupMemWwn swGroupMemPos swTrunk swSwitchTrunkable swTrunkTable swTrunkEntry swTrunkPortIndex swTrunkGroupNumber swTrunkMaster swPortTrunked swTrunkGrpTable swTrunkGrpEntry swTrunkGrpNumber - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 277
service parameters 76 FX_Port fabric login table 80, 104 G general group 128 H ha MIB overview 185 ha-MIB traps 191 ha-MIB traps and sample triggers 193 help, obtaining 26, 27 high-availability group 187 HP authorized reseller 27 storage web site 27 Subscriber's choice web site 27 technical support - HP StorageWorks 2/64 | HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVH - Page 278
brocade MIBs 32 sensor variables 257 Series 3000 Variables 258 service group 250 SNMP configuration variables 258 switch group 178 switch variables 257 sw-MIB system organization of MIB objects 133 symbols in text 26 system group 41, 146 T TCP connection table 59 TCP group 57 technical support, HP
HP StorageWorks
Fabric OS 5.x MIB reference guide
Part number: AA–RVHXB–TE
Second edition: September 2005