HP StorageWorks 2/8-EL SAN switch 2/8 version 3.0.x installation guide
HP StorageWorks 2/8-EL - SAN Switch Manual
View all HP StorageWorks 2/8-EL manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks 2/8-EL manual content summary:
- HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 1
installation guide hp StorageWorks SAN switch 2/8 Product Version: Version 3.0.x Second Edition (February 2003) Part Number: AA-RSB6B-TE This installation guide provides basic procedures for setting up, configuring, and managing the SAN switch 2/8 EL and SAN switch 2/8 Power Pak models. - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 2
the Brocade B weave logo, Brocade: the Intelligent Platform for Networking Storage, SilkWorm, and SilkWorm Express, are trademarks or registered trademarks of additional warranty. Printed in the U.S.A. hp StorageWorks SAN Switch 2/8 Installation Guide Second Edition (February 2003) Part Number: - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 3
10 Conventions 11 Document Conventions 11 Text Symbols 11 Equipment Symbols 12 Rack Stability 14 Getting Help 15 HP Technical Support 15 HP Storage Website 15 HP Authorized Reseller 16 1 Overview 17 SAN Switch 2/8 Features 18 Firmware 18 Hardware 18 SFP Media Side 19 Optical Ports 20 - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 4
Core PID Format 52 Modifying Domain IDs 53 Specifying Custom Status Policies 54 Connecting a Cable to an SFP Module 55 Verifying Operation 56 Installing Multiple Switches into an Existing SAN 57 Cascading Switches 58 4 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 5
the SAN Switch 2/8 67 Changing the Admin Password and User ID 67 Configuring the IP and Fibre Channel Address 68 Displaying Devices within the Fabric 69 Checking the Firmware Version 69 Setting the Switch Date and Time 69 Displaying Switch Configuration Settings 70 SAN Switch 2/8 Diagnostic - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 6
a cable into an SFP 56 Tables 1 Document Conventions 11 2 SAN Switch 2/8 Orderable Hardware 21 3 Shipping Carton Contents 29 4 Front Panel LED Patterns During Normal Operation 61 5 Rear Panel LED Patterns During Normal Operation 64 6 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 7
Contents 6 Physical Specifications 86 7 Power Supply Specifications 86 8 Environmental Requirements 87 9 Cabling Pinouts if Pin 7 is Used 88 hp StorageWorks SAN Switch 2/8 Installation Guide 7 - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 8
Contents 8 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 9
porouvitdetshinisforGmautioindtoehelp you set up and configure the hp StorageWorks SAN Switch 2/8. About this Guide About this Guide topics include: ■ Overview, page 10 ■ Conventions, page 11 ■ Rack Stability, page 14 ■ Getting Help, page 15 hp StorageWorks SAN Switch 2/8 Installation Guide 9 - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 10
documentation and firmware releases, please visit the following hp StorageWorks website: http://www.q.c.com/storage/productindexdisk.html For information about Fibre Channel standards, visit the Fibre Channel Industry Association website: http://www.fibrechannel.org. 10 hp StorageWorks SAN Switch - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 11
www.hp.com Text Symbols The following symbols may be found in the text of this guide. They have the following meanings. WARNING: Text set off in this manner indicates that failure to follow directions in the warning could result in bodily harm or death. hp StorageWorks SAN Switch 2/8 Installation - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 12
symbols indicates the presence of electrical shock hazards. Enclosed area contains no operator serviceable parts. WARNING: To reduce the risk of personal safety from electrical shock hazards component, allow the surface to cool before touching. 12 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 13
About this Guide Power supplies or systems marked with these symbols indicate the presence of multiple sources of or damage to the equipment, observe local occupational health and safety requirements and guidelines for manually handling material. hp StorageWorks SAN Switch 2/8 Installation Guide 13 - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 14
About this Guide Rack Stability Rack stability protects personal and equipment. WARNING: To reduce the risk of personal safety or damage to the at any time. A rack may become unstable if more than one rack component is extended for any reason. 14 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 15
, specific questions HP Storage Website The HP website has the latest information on this product. Access storage at: http://thenew.hp.com/country/us/eng/prodserv/storage.html From this website, select the appropriate product or solution. hp StorageWorks SAN Switch 2/8 Installation Guide 15 - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 16
this Guide HP Authorized Reseller For the name of your nearest HP authorized reseller: ■ In the United States, call 1-800-345-1518 ■ In Canada, call 1-800-263-5868 ■ Elsewhere, see the HP website for locations and telephone numbers: http://www.hp.com. 16 hp StorageWorks SAN Switch 2/8 Installation - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 17
HP StorageWorks SAN Switch 2/8 is a high-performance 8-port, 2 gigabit (Gb) Fibre Channel (FC) switch used to interconnect storage devices, hosts, and servers in a SAN. The hp StorageWorks SAN switch 2/8 is offered in two configurations; the 2/8 EL and 2/8 Power Pak. Refer to the hp StorageWorks SAN - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 18
: ■ A 1 Unit (U) chassis, designed for mounting in a 19-inch rack, with forced-air cooling that flows from the back of the switch to the front ■ 8 optical ports, compatible with Small Form Factor Pluggable media (SFPs), supplied by the customer 18 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 19
switch LED. 1 2 3 4 5 6 9 8 1 Serial port 2 Optical ports (8) 3 Port status LEDs (8) 4 Port speed LEDs (8) 5 Ethernet speed LED Figure 1: SFP media side 7 SHR-2493B 6 Ethernet activity LED 7 Ethernet port 8 Switch power LED 9 Power connector hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 20
For specific information about ISL trunking, refer to the hp StorageWorks ISL Trunking V3.0.x/V4.0.x User Guide. SFPs The ports connect to SFP media. SFPs are universal and self-configuring. Fan Side Figure 2 shows the fan side of the SAN Switch 2/8. The rear panel houses the five fans, and port - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 21
Overview Optional Hardware Kits HP provides the following optional hardware kits in support of the SAN Switch 2/8, see Table 2. Table 2: SAN Switch 2/8 Orderable Hardware Accessory Short wavelength SFP Long wavelength SFP, 10 km 2m LC-to-LC Fibre Channel (fc) cable 2m LC-to-LC multi-mode fc - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 22
Overview 22 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 23
Configuring SAN Switch 2/8 Network Addressing, page 47 ■ Connecting the SAN Switch 2/8 to the LAN, page 50 ■ Connecting a Cable to an SFP Module, page 55 ■ Installing Multiple Switches into an Existing SAN, page 57 ■ Cascading Switches, page 58 hp StorageWorks SAN Switch 2/8 Installation Guide 23 - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 24
2/8 EL to Full Fabric. To upgrade, you must install the optional Full Fabric license on each SAN Switch 2/8 EL. See the "Four Switch Limitation Workarounds" section on page page 27 for instructions on how to purchase the Full Fabric license. 24 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 25
every 75 seconds (not configurable). Figure 3 shows a typical Web Tools Warning Message. Figure 3: Four switch limitation Web Tools error message Note: The SAN Switch 2/8 EL displays a separate error condition warning message in the dialog box. hp StorageWorks SAN Switch 2/8 Installation Guide 25 - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 26
a SAN Switch 2/8 EL with a IV_FABRIC license installed, the four switch limitation warning messages display. If the IV_FABRIC license is not installed, Quiet Mode works as described in the hp StorageWorks Fabric OS V3.0.x/V4.0.x Reference Guide. 26 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 27
authorized HP Sales representative, or go to the HP website: http://www.hp.com ■ In fabrics which contain five or more switches and that have at least one switch with the IV_FABRIC license installed, reduce the number of switches to four or less. hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 28
Rack Mount Kit shown in Figure 5 may not represent the kit that shipped with your switch. HP reserves the right to substitute Rack Mount Kits, providing applicable instructions with each switch. 3 4 5 1 2 6 Figure 5: Carton contents SHR-2495B 28 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 29
a flat surface * Depending on time of purchase, the Fixed Rack Mount Kit items listed in Table 3 may not represent the kit that shipped with your switch. hp StorageWorks SAN Switch 2/8 Installation Guide 29 - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 30
by the fans mounted on the rear of the chassis. The air is expelled through vents in the front of the chassis. HP recommends installing the switch so that air intake and exhaust for all components in the rack is flowing in the same direction. 30 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 31
Power capability of 75 watts, maximum The switch uses a universal power supply capable of functioning worldwide without voltage jumpers or switches. The power supply is auto ranging in terms of accommodating input voltages and line frequencies. hp StorageWorks SAN Switch 2/8 Installation Guide 31 - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 32
runs a Power On Self-Test (POST). Note: Do not connect the switch to the network until the IP address is correctly set. For instructions on how to set the IP address, see the "Configuring SAN Switch 2/8 Network Addressing" section on page 47. 32 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 33
of the pairs of vertically aligned holes in both the bracket and in the switch. c. Insert one 8-32 x 5/16 inch screw (Item 7) into one of the single holes in both the bracket and in the switch. d. Tighten screws to a torque of 15-inch pounds. hp StorageWorks SAN Switch 2/8 Installation Guide 33 - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 34
the Fixed Rack Mount Kit rails to the switch 3. Position the switch in the rack as shown in Figure 6, providing temporary support under the switch (use clamps if necessary). 4. To secure rail. 6. Tighten all screws and torque to 25-inch pounds. 34 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 35
rear bracket (Item 2) to the left rear rack rail. 11. Tighten all screws to a torque of 25-inch pounds. 12. Connect the SAN Switch 2/8 power cord to the power connector on the switch. See Figure 7. Figure 7: Connecting the power cord hp StorageWorks SAN Switch 2/8 Installation Guide SHR-2496B 35 - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 36
SAN Switch 2/8 Optional HP System/e Rack This section lists instructions for installing the SAN Switch 2/8 in the optional HP System/e Rack. Items Required for the HP System/e Rack The HP System/e Rack Kit consists of the following items: ■ HP 36 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 37
5/8 Phillips pan-head screw with attached lock washer (Use if installing in HP 9000 Series rack/ EIA rack)) (6) Spacer (Use if installing in HP 9000 Series rack/ EIA rack) (4) M5 flat washer ((Use if installing in HP 9000 Series rack/ EIA rack) hp StorageWorks SAN Switch 2/8 Installation Guide 37 - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 38
1. Select a mounting location in the rack for the switch. 2. Attach the rear rail-tray brackets to the rear rack uprights by installing each of the two mounting brackets with one M5 Torx head screw with captive lock washer as shown in Figure 8. 38 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 39
Installing the SAN Switch 2/8 2 1 1 Rear rail tray bracket 2 M5 Torx head screw with captive lock washer Figure 8: Installing the rear rail tray brackets SHR-2557 hp StorageWorks SAN Switch 2/8 Installation Guide 39 - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 40
Installing the SAN Switch 2/8 3. Install two M5 U-type Tinnerman clips for each of the front columns of the rack in the top and bottom portion of the outer rail flush against the rear rail-tray brackets. Install them as shown in Figure 10. 40 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 41
required. [8] Adjust the size of the outer graphic frame as required. Delete this set of instructions 1 Rubber washer (1 of 2) 2 Rear rail tray bracket (1 of 2) Figure 10: Installing install the upper left and lower right screws until later. hp StorageWorks SAN Switch 2/8 Installation Guide 41 - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 42
of any longer lengths can cause damage to internal components of the switch. Be sure to install the flat washers along with the pan-head screws. Before tightening screws, make sure that the rails are centered to the overall height of the switch. 42 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 43
. 1 4 3 2 1 Plenum 2 8-32 x 5/16 phillips pan head screws 3 Flat washers 4 Inner rails (1 of 2) Figure 12: Assembling the inner rails SHR-2561A 6. Insert the switch with the attached inner rails into the outer rails as shown in Figure 13. hp StorageWorks SAN Switch 2/8 Installation Guide 43 - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 44
Installing the SAN Switch 2/8 SHR-2562A Figure 13: Installing the switch into an HP Rack 7. Install the two remaining M5 Torx screws into the upper left and lower right holes to complete the installation. See Figure 14. 44 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 45
by default each time it is turned on. Note: Do not connect the switch to the network until the IP address is correctly set. For instructions on how to set the IP address, see "Configuring SAN Switch 2/8 Network Addressing," later in this chapter. hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 46
run during POST via LED activity, the error log, or the CLI using the errShow command. For more information about error messages, refer to the hp StorageWorks Fabric OS V3.0.x/V4.0.x Reference Guide. 46 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 47
time setup, you must replace the factory IP, subnetmask and gateway addresses with addresses provided by your Network Administrator. 1. Remove the shipping plug from the SAN Switch 2/8 Serial port. hp StorageWorks SAN Switch 2/8 Installation Guide 47 - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 48
and establish a connection to the switch using a terminal emulator application (such as Hyperterminal). Note: Step 6 shows instructions specific to HyperTerminal. If using : 9600 ■ Databits: 8 ■ Parity: None ■ Stop bits: 1 ■ Flow control: None 48 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 49
the initial setting of the IP address and for service purposes. Using the Serial port during normal switch operation or for regular maintenance is not recommended. 8. Record the IP address on the label affixed to the SAN Switch 2/8 front panel. hp StorageWorks SAN Switch 2/8 Installation Guide 49 - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 50
. Verify that the switch is not accessed from any other connections during the remaining steps. 4. Log on to the switch with administrative privileges by telnet. The default administrative logon is admin and the default password is password. 50 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 51
the edge switch (for example, SAN Switch 2/8) PID format matches the Core switch's PID format, before connecting to the SAN. For example, switches with firmware V3.0.2f or later have the PID set to 1. For a SAN to work correctly, all HP StorageWorks SAN switches or HP Surestore FC switches must have - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 52
The following displays: Configure... 4. Type y at the Fabric parameters prompt, Fabric parameters (yes, y, no, n): [no] y 5. Locate the line, "Core Switch PID Format: (0..1) [0] 1," and type 1. 6. Press Enter until the following prompt appears. 52 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 53
chapter, for instructions on connecting Fibre Channel cables. 9. If necessary, type cfgEnable to re-establish zoning. Note: Once the switch PID format is set, it is stored in the flash memory of the switch and it is NOT necessary to set it again during subsequent firmware upgrades. Modifying Domain - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 54
at the prompt. switchStatusPolicySet 2. Specify the desired status policies. To completely deactivate the alarm for a particular condition, enter 0 at the prompt for that condition. 54 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 55
steps to connect the SFPs and cables to SAN Switch 2/8 ports as required. Note: The ports and cables used in trunking groups must meet specific requirements. For a list of these requirements, refer to the hp StorageWorks ISL Trunking V3.0.x/V4.0.x User Guide. 1. Remove the shipping plugs from the - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 56
is running properly. 1. Access your browser. 2. At the URL address window type, http://your switch IP address. 3. Press Enter. 4. If connected properly, the name of your switch appears (in green) in the Web browser window, indicating Healthy/OK. 56 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 57
SAN. The default domain setting is 1. Note: If a switch boot failure occurs, the switch must be taken offline for repair or replacement. Contact your HP Technical Support for assistance. 5. Power off the new switch and connect one Fibre Channel cable from the SAN to the new switch. hp StorageWorks - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 58
may change when disabling and enabling one of the switches, or rebooting one of the switches if the domain is not set using the configure command. Switch parameters for all switches in a SAN must be the same, or the switch may not join the SAN. 58 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 59
Managing the SAN Switch 2/8 3 This chapter covers the following topics: ■ Interpreting LED Activity, page 60 ■ Management Overview, page 65 ■ Running Basic Switch Operations Using Telnet, page 67 ■ SAN Switch 2/8 Diagnostic Tests, page 70 hp StorageWorks SAN Switch 2/8 Installation Guide 59 - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 60
is normal and does not indicate a problem. Note: Any errors related to LED activity are listed in the error log. For information about the error log, refer to the hp StorageWorks Fabric OS V3.0.x/V4.0.x Procedures Guide. Front Panel LEDs The SAN Switch 2/8 front panel includes the following LEDs - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 61
. 2. Clear error log. 3. Rerun diagnostics to verify error condition is fixed. Check media and cable. No action required. Verify correct device is connected to port. hp StorageWorks SAN Switch 2/8 Installation Guide 61 - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 62
the PortEnable command; refer to the hp StorageWorks Fabric OS Reference. 1. Check port status LEDs, error log, and cable or loopback plug. 2. Clear error log. Check configuration of Fibre Channel loop. No action required. No action required. 62 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 63
Managing the SAN Switch 2/8 Table 4: Front Panel LED Patterns During Normal Operation (Continued) . Recommended Action No action required. No action required. Verify switch is powered on, and Ethernet cable is firmly seated. No action required. hp StorageWorks SAN Switch 2/8 Installation Guide 63 - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 64
. 1. Check error log, Port Status LEDs, port media, and cables or loopback plugs. 2. Clear error log. 3. Rerun diagnostics to verify error condition is fixed. 64 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 65
the SAN Switch 2/8 Management Overview The SAN Switch 2/8 can be managed using TCP/IP protocol, in-band over Fibre Channel, switch, or port. For more information refer to the hp StorageWorks Web Tools V3.0.x/V4.0.x User Guide. Note: The HP StorageWorks SAN Switch 2/8 EL and HP StorageWorks SAN Switch - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 66
Features Licensed features such as QuickLoop and Fabric Watch are already loaded onto the switch firmware, but must be enabled with a license key. Once you have purchased these features feature to activate. License keys are case sensitive. 66 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 67
: For security reasons, the first time you log into the Fabric OS you are requested to change the admin user ID and system password. 1. Log in to the switch as the admin user. 2. At the command line enter the following command: Password admin hp StorageWorks SAN Switch 2/8 Installation Guide 67 - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 68
to 40 characters in length. 6. At the New Password prompt, enter the new password exactly as entered to the previous prompt. 7. Press Enter to commit the configuration to the firmware. Configuring the IP and Fibre Channel Address The SAN Switch 2/8 is shipped with a default IP address of 10.77.77.77 - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 69
command: date MMDDhhmmYY where: - MM is the month, valid values are 01-12 - DD is the date, valid values are 01-31 - hh is the hour, valid values are 00-23 - mm is minutes, valid values are 00-59 - YY is the year, valid values are 00-99 hp StorageWorks SAN Switch 2/8 Installation Guide 69 - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 70
switch supplier for repair. Any errors detected during POST are written to the system log, accessible through the errShow command. For more information about error messages, refer to the hp StorageWorks Fabric OS V3.0.x/V4.0.x Procedures User Guide. 70 hp StorageWorks SAN Switch 2/8 Installation - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 71
specific diagnostic tests and how to run them, refer to the hp StorageWorks Fabric OS V3.0.x/V4.0.x Procedures User Guide. Note: The transmit and receive speed of the links may be temporarily locked to a specific speed during diagnostic testing. hp StorageWorks SAN Switch 2/8 Installation Guide 71 - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 72
Managing the SAN Switch 2/8 72 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 73
Settings and Upgrading Firmware 4 This chapter provides the following information: ■ Backing Up System Configuration Settings, page 74 ■ Upgrading or Restoring the Switch Firmware, page 76 ■ Downloading Firmware from the HP Website, page 76 hp StorageWorks SAN Switch 2/8 Installation Guide 73 - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 74
prompts you for each parameter, as follows: Example: switch:admin> configupload Server Name or IP Address [host]: 123.45.678.901 User Name [user]: kelev File Name [config.txt]: switch1 Protocol (RSHD or FTP) [rshd]: ftp Password: upload complete 74 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 75
location and filename of the system configuration file, and password is the password for the user ID specified. Note: The password operand is only required if you are using FTP. 5. Reboot the switch by entering the following command: fastBoot hp StorageWorks SAN Switch 2/8 Installation Guide 75 - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 76
command: fastBoot Downloading Firmware from the HP Website To download the firmware from the HP website, go to http://www.hp.com/support. The website contains the required loaders and instructions for downloading the firmware to a switch. 76 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 77
radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in FCC could void the user's authority to operate the equipment. hp StorageWorks SAN Switch 2/8 Installation Guide 77 - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 78
Noise Declaration Schalldruckpegel Lp = 46.1 dB(A)Am Arbeitsplatz (operator position) Normaler Betrieb (normal operation)Nach ISO 7779:1999 (Typprüfung) VCCI EMC Statement (Japan) 78 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 79
Harmonics Conformance (Japan) BSMI EMC Statement (Taiwan) Regulatory Compliance Notices RRL EMC Statement (Korea) hp StorageWorks SAN Switch 2/8 Installation Guide 79 - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 80
in incorrect operation of the system and points of access may emit laser radiation above the Class 1 limits established by the IEC and U.S. DHHS. 80 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 81
or proper disposal, contact your HP authorized reseller or your authorized service provider. WARNING: Your switch contains an internal lithium manganese dioxide system or return them to HP, your authorized HP partners, or their agents. hp StorageWorks SAN Switch 2/8 Installation Guide 81 - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 82
Regulatory Compliance Notices 82 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 83
removing them from their containers. ■ Avoid touching pins, leads, or circuitry. ■ Always make sure you are properly grounded when touching a static-sensitive component or assembly. hp StorageWorks SAN Switch 2/8 Installation Guide 83 - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 84
mats. ■ Use conductive field service tools. ■ Use a portable field service kit with a folding static-dissipating work mat. If you do not have any of the suggested equipment for proper grounding, have an HP authorized reseller install the part. 84 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 85
Technical Specifications This appendix covers the following topics: ■ Dimensions ■ Power supply specifications ■ Environmental specifications ■ Memory specifications ■ Serial port specifications C hp StorageWorks SAN Switch 2/8 Installation Guide 85 - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 86
Technical Specifications Dimensions Table 6 lists SAN Switch 2/8 dimensions. Table 6: Physical Specifications Dimension Height Depth Width Weight (with both power supplies) Value start at 25 degrees Celsius Fused in both hot & neutral lines 86 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 87
MB per switch ■ Flash Memory: Dual 8 MB ■ Boot Flash: 512K bytes of 8-bit for system boot The centralized memory maximizes the overall switch throughput by guaranteeing full transmit and receive bandwidth to all Fibre Channel ports at all times. hp StorageWorks SAN Switch 2/8 Installation Guide 87 - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 88
port requires a straight serial cable with a female 9-pin subminiature-D connector. Only pins 2, 3, and 5 are supported; if pin 7 is used, the signal must always be driven high, using the pinouts listed in Table 9. the serial port is not in use. 88 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 89
to interface with a set of services. Arbitrated Loop A shared 100 MBps or 200 MBps Fibre Channel transport structured as a loop. Can support up to 126 devices and one fabric any-to-any connectivity, and allows nodes to transmit simultaneously. hp StorageWorks SAN Switch 2/8 Installation Guide 89 - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 90
can connect a Fibre Channel link to an ATM switch and switch components are mounted. Circuit An established communication path between two ports. Consists of two virtual circuits capable of transmitting in opposite directions. See also Link. 90 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 91
be manually assigned. E_D_TOV Error Detect Time-out Value; the minimum amount of time a target waits for a sequence to complete before initiating recovery. Can also be defined as the maximum time allowed for a round-trip transmission before an error condition is declared. hp StorageWorks SAN Switch - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 92
referred to as a switched fabric. See also Topology, SAN, Cascade. FC-AL-3 The Fibre Channel Arbitrated Loop standard defined by ANSI. Defined on top of the FC-PH standards. FC-FLA The Fibre Channel Fabric Loop Attach standard defined by ANSI. 92 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 93
Fibre Channel switches. Full Fabric The licensing that allows multiple E_Ports on a switch, making it possible to create multiple ISL links. Full-duplex A mode of communication that allows the same port to simultaneously transmit and receive frames. hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 94
and maintain bit, byte, and word synchronization. ISL Interswitch Link; a Fibre Channel link from the E_Port of one switch to the E_Port of another. See also E_Port, Cascade. Isolated E_Port An protocol definition or upper-level protocol mapping. 94 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 95
Link Services A protocol for link-related actions. Link As applies to Fibre Channel, Fibre Channel port or to another N_Port in a point-to-point connection. NAA Network Address Authority. An identifier that indicates the format of a network address. hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 96
. Point-to-point A Fibre Channel topology that employs direct links between each pair of communicating entities. See also Topology. Port Cage The metal casing extending out of the optical port on the switch, and in which the SFP can be inserted. 96 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 97
Fibre Channel port. Communicated during login and port discovery. POST Power On Self-Test; a series of tests run by a switch after it is turned on. Private Device A device that supports a frame can be delayed in the fabric and still be delivered. hp StorageWorks SAN Switch 2/8 Installation Guide 97 - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 98
over other protocols, such as UDP/IP, because it does not rely on the underlying communication protocols. Switch Name The arbitrary name assigned to a switch. Switch Port A port on a switch. Switch ports can be E_Ports, F_Ports, or FL_Ports. 98 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 99
Glossary Switch Hardware that routes frames according to Fibre Channel protocol and is controlled by software. Target A storage device on a Fibre Channel network. Tenancy The time from when a port are connected by a different type of network. hp StorageWorks SAN Switch 2/8 Installation Guide 99 - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 100
Well-known Address As pertaining to Fibre Channel, a logical address defined by the Fibre Channel standards as assigned to a specific function, and stored on the switch. Workstation A computer used to access accessed by devices in the same zone. 100 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 101
user ID 67 changing the switch password 67 changing the user id 67 chassis 18 checking license 24 checking POST results 46 checking results 46 checking the firmware version 69 cli 65 hp StorageWorks SAN Switch 2/8 Installation Guide Index Index cli errors for four switch limitation 25 command line - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 102
64 Port Speed LEDs 60 Port Status LEDs 60 location of switch 30 logging into a switch 67 M malfunctions during POST 57 management interface 67 modifying domain IDs 53 mounting methods surface 33 multiple switches 57 N network addressing 47 102 hp StorageWorks SAN Switch 2/8 Installation Guide - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 103
by 65 specifications power supply 86 status policies, configuring 54 Storage Area Network 17 installing multiple switches 57 subnetmask 68 switch cascading 58 switch location requirements 30 symbols in text 11 symbols on equipment 12 Index hp StorageWorks SAN Switch 2/8 Installation Guide 103 - HP StorageWorks 2/8-EL | SAN switch 2/8 version 3.0.x installation guide - Page 104
47 violation timer errors 26 voltage capability 31 W warning rack stability 14 symbols on equipment 12 web tools 25 web tools summary 65 websites HP storage 15 weight 86 workarounds for the four switch limitation 27 Z zoning summary 18 104 hp StorageWorks SAN Switch 2/8 Installation Guide
installation
guide
hp
StorageWorks
SAN switch 2/8
Product Version:
Version 3.0.x
Second Edition (February 2003)
Part Number:
AA-RSB6B-TE
This installation guide provides basic procedures for setting up, configuring, and managing the
SAN switch 2/8 EL and SAN switch 2/8 Power Pak models.