HP StorageWorks 2000fc manual content summary:
- HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 1
HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide Part number: 500910-001 First edition: January 2009 - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 2
to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 3
attach configurations 28 Two servers/two switches 28 Connecting remote management hosts 28 5 Basic operation 29 Powering on/powering off 29 Updating firmware 29 Selecting an appropriate time to perform the online upgrade 29 HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide 3 - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 4
LEDs 34 MSA2312fc and MSA2324fc 34 MSA2000 3.5 12-drive enclosure 36 system date and time 40 To use manual date and time settings 40 To of SMU 42 8 Troubleshooting 43 Fault isolation methodology 43 LED off 47 Is the drive enclosure Fault/Service Required LED amber 47 Controller failure in - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 5
Taiwan battery recycling notice 71 Power cords 71 Japanese power cord notice 71 Electrostatic discharge 71 Preventing electrostatic damage 71 Grounding methods 72 Index 73 HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide 5 - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 6
6 - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 7
. 23 3 Cabling connections between a dual-controller enclosure and up to three MSA2000 3.5 12-drive enclosures 23 4 MSA2312fc exploded view 54 5 MSA2324fc exploded view 56 6 MSA2000 3.5 12-drive enclosure exploded view 58 HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide 7 - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 8
8 - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 9
52 11 MSA2312fc parts list 54 12 MSA2324fc parts list 56 13 MSA2000 3.5 12-drive enclosure parts list 58 14 Rackmount enclosure dimensions 63 15 Rackmount enclosure weights 63 16 Operating environmental specifications 63 HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide 9 - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 10
10 - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 11
for this product: • HP StorageWorks MSA2000 Family SMU online help • HP StorageWorks MSA2000 Family CLI online help • HP StorageWorks MSA2000 Family CLI reference guide These and other HP documents can be found on the HP documents web site: http://www.hp.com/support/. Document conventions and - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 12
: Provides clarifying information or specific instructions. NOTE: Provides additional information. TIP StorageWorks product. If a CSR part needs replacing, HP ships the part directly to you so that you can install it at your convenience. Some parts do not qualify for CSR. Your HP-authorized service - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 13
com/support/ • http://www.docs.hp.com Documentation feedback HP welcomes your feedback. To make comments and suggestions about product documentation, please send a message to [email protected]. All submissions become the property of HP. HP StorageWorks 2312fc and 2324fc Modular Smart Array - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 14
14 - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 15
list of supported operating systems and drives. QuickSpecs can be found from your HP MSA products page at http://www.hp.com/go/msa. Select MSA SAN Arrays, and then select your product. The link for QuickSpecs will be on the right. HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide 15 - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 16
16 Overview - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 17
/Activity LED 3 Hard drive Fault/UID LED 4 5 6 4 Unit Identification (UID) LED 5 Fault ID LED 6 Heartbeat LED 4 5 6 4 Unit Identification (UID) LED 5 Fault ID LED 6 Heartbeat LED HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide 17 - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 18
MSA2312fc and MSA2324fc 1 2 3 45 6 7 12 1 Power supplies - AC 2 Power switches - AC 3 Host ports 4 CLI port 5 Ethernet port 18 Components 9 - 8 6 Service port (used by service personnel only) 7 Expansion port 8 Optional FC controller 9 DC Power supply (2) - (DC model only) 10 Power switches - DC - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 19
MSA70 that is running firmware version 2.18 or later. For information about the MSA70, see the HP StorageWorks 70 Modular Smart Array Enclosure user guide located on the MSA2000 Software Support/Documentation CD shipped with your product or at http://hp.com/support/manuals. Cache To enable faster - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 20
must transport the CompactfFash from the failed controller to the replacement controller using a procedure outlined in the HP StorageWorks 2312fc/2324fc controller replacement instructions, shipped with the replacement controller. Failure to use this procedure will result in the loss of data stored - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 21
and optional See the racking instructions drive enclosures in the enclosures See Updating firmware. have the latest firmware. • Set the MSA2000 product, also see the MSA2000 Software Support/Documentation CD shipped with your product. HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 22
for QuickSpecs will be on the right. IMPORTANT: The MSA2324fc can also be attached to an MSA70 that is running firmware version 2.18 or later. For information about the MSA70, see the HP StorageWorks 70 Modular Smart Array Enclosure user guide located on the MSA2000 Software Support/Documentation - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 23
one MSA2000 3.5 12-drive enclosure 1A 1B In Out 2A In Out 2B 3A In Out In Out 3B 4A In Out In Out 4B Figure 3 Cabling connections between a dual-controller enclosure and up to three MSA2000 3.5 12-drive enclosures HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 24
MSA2000 Software Support/Documentation CD shipped with your product. Setting management port IP addresses using DHCP 1. Look in the DHCP server's pool of leased addresses for two IP addresses assigned to "HP StorageWorks MSA Storage." 2. Use a network management utility to discover "HP StorageWorks - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 25
Parameter Terminal emulation mode Font Value VT-100 or ANSI (for color support) Terminal Translations None Columns 80 4. In the terminal emulator, connect to control None 5. Press Enter to display the CLI prompt (#). HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide 25 - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 26
6. At the prompt, type the following command to set the values you obtained in Step 1 for each Ethernet management port, first for controller A and then for controller B: set network-parameters ip address netmask netmask gateway gateway controller a|b where: • address is the IP address of the - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 27
support/manuals for the latest MSA2000 supported cable configurations guide. This document is updated whenever newly supported configurations are added. Loop/Point-to-Point Topology 2312fc Modular Smart Array and 2324fc Modular Smart Array use Fibre Channel Arbitrated Loop (loop) topology by default - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 28
Two servers/one dual-ported HBA per server/dual path Server 1 Server 2 Connecting switch attach configurations Two servers/two switches Server 1 Server 2 Connecting remote management hosts The management host directly manages systems out-of-band over an Ethernet network. 1. Connect an Ethernet - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 29
msa. Select MSA SAN Arrays, select your product, and go to Support. For detailed steps on updating the firmware, see the reference guide or the CLI reference guide. For information on logging into SMU, see Configuring a system for the first time. HP StorageWorks 2312fc and 2324fc Modular Smart Array - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 30
30 Basic operation - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 31
acknowledged but the problem needs attention. Off - No fault condition exists. Green - The enclosure is powered on with at least one power supply operating normally. Off - Both power supplies are off; the system is powered off. HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide 31 - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 32
Hard drive LEDs 12 21 LED Description 1 Fault/UID (amber/blue) 2 Online/Activity (green) Table 5 Hard drive LED combinations Online/Activity (green) On Fault/UID (amber/blue) Off Blinking irregularly Off Off Amber; blinking regularly (1 Hz) On Blinking irregularly Off Off On or blinking - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 33
current operation and cause data loss. The drive is rebuilding. Either there is no power, the drive is offline, or the drive is not configured. HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide 33 - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 34
Description Definition 1 Power supply LEDs See Power supply LEDs. 2 Host Link Status/Activity FC port 1 Blinking green (1 Hz) - No link is detected. 2G LED illuminates is not OK. 7 Fault/Service Required Amber - A fault has been detected or a service action is required. Blinking amber - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 35
in each controller's cache and one in each controller's CompactFlash. Blinking green - At least one host port has I/O activity. Off - Host ports have no activity. HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide 35 - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 36
MSA2000 3.5 12-drive enclosure 12 LED Description 1 Power supply LEDs 2 Unit Locator 3 SAS In Port Status 4 OK to Remove 5 Fault/Service Required 6 OK 7 SAS Out Port Status 3 4 56 7 Definition See Power supply LEDs. Off - Normal operation Blinking white- Physically identifies the - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 37
1 2 2 AC model LED Description 1 Input Source Power good 2 DC Voltage/Fan Fault/Service Required DC model Definition Green - Power is on and input voltage is normal. Off - Power RPM. Off- DC output voltage is normal. HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide 37 - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 38
38 LED descriptions - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 39
need to refresh it and if you click Back, you may exit the application. • If an option name has an asterisk (*), the option is required. HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide 39 - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 40
email messages have correct time stamps. You can set the date and time manually or configure the system to use Network Time Protocol (NTP) to obtain them to use that time server, with no further time adjustment. To use manual date and time settings 1. In the Configuration View panel, right-click the - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 41
, including system name, contact, location, and description. • Up to four email addresses and three SNMP trap hosts to receive notifications of system events. • Parameters for FC and iSCSI controller host ports. HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide 41 - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 42
using it, other manage users cannot log in to the same controller module and your IP address stays logged in for 30 minutes (the default auto-logout timeout setting). 1. Click Sign Out in the upper right-hand corner. The Logout Request dialog is displayed. 2. Click Logout. 42 Configuring a system - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 43
8 Troubleshooting Fault isolation methodology The MSA2000 Family storage In addition, the type of fault can help you isolate the problem to hardware or software. Isolate the fault Occasionally it might become event log for errors. HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide 43 - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 44
for specific information regarding the failure. Is the controller back panel Fault/Service Required LED amber? Answer No Yes (blinking) Possible Reasons System functioning and reinsert it. • Contact an authorized service provider for assistance. • Replace the controller. 44 Troubleshooting - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 45
specific information regarding the fault. • Isolate the fault. • Contact an authorized service provider for assistance. • Check the event log for specific information regarding the of a specific fault in a host data path component. HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide 45 - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 46
functioning properly. The link is down. Actions No action required. Use standard networking troubleshooting procedures to isolate faults on the network. Is the power supply's AC Power the fault. • Isolate the fault. • Contact an authorized service provider for assistance. 46 Troubleshooting - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 47
fault. • Isolate the fault. • Contact an authorized service provider for assistance. • Replace if necessary. • If installing an I/O module FRU, try removing and reinstalling the new I/O module, and check the event log for errors. HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide 47 - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 48
disks. If the problem persists, replace the controller. See Transporting Cache. The system is flushing data to disks. If the problem persists, replace using a procedure outlined in the HP StorageWorks 2312fc/2324fc controller replacement instructions, shipped with the replacement controller. - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 49
hosts are having trouble accessing the storage time can complicate the troubleshooting process. 1. Halt system. 3. Reseat the SFP and FC cable. Is the host link status problem, which can occur with SFPs, damaged cables, and HBAs. HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide 49 - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 50
one variable at a time can complicate the troubleshooting process. 1. Halt all I/O to the with a known good link status. This step isolates the problem to the expansion cable or to the controller module's expansion power supply's DC Voltage/Fan Fault/Service Required LED is off or by using SMU - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 51
points within each enclosure to alert you to problems. Power, cooling fan, temperature, and status of these sensors to perform SCSI enclosure services (SES) functions. The following sections describe each 100°C None 0°C 100°C HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide 51 - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 52
Event/Fault LED condition Power supply 1 voltage, 12V Power supply 1 voltage, 5V Power supply 1 voltage, 3.3V < 11.00V > 13.00V < 4.00V > 6.00V < 3.00V > 3.80V 52 Troubleshooting - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 53
product warranty. • No CSR - The part is not available for customer self repair. For assistance, contact an HP-authorized service provider. NOTE: For an updated list of customer self repair parts, go to http://www.hp.com/support/. HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide 53 - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 54
F 7 6 5 3 4 1 2 Figure 4 MSA2312fc exploded view Table 11 MSA2312fc parts list Item Description Spares part number 1 SPS-BLANK,HDD 481344-001 2 Hard drives - a) SPS-DRV, HD 146GB MSA2 3.5" 15K DP SAS 480937-001 b) SPS-DRV, HD 300GB MSA2 3.5" 15K DP SAS 480938-001 c) SPS-DRV, HD 450GB - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 55
SPS-CA KIT, DB9 shown DB9-M to DB9-F (CLI cable) Spares part number 457637-001 481322-001 508297-001 CSR Mandatory Optional Mandatory Mandatory Mandatory HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide 55 - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 56
7 6 5 3 4 1 2 Figure 5 MSA2324fc exploded view Table 12 MSA2324fc parts list Item Description Spares part number 1 SPS-BLANK,HDD 2 Hard drives a) 36-GB SAS, 10K rpm b) 36-GB SAS, 15K rpm c) 72-GB SAS, 10K rpm d) 72-GB SAS, 15K rpm e) 146-GB SAS, 10K rpm f) 60-GB SATA, 5.4 rpm g) 80-GB - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 57
, DB9 shown (DB9-M to DB9-F CLI cable) - 481320-001 545764-001 457637-001 481322-001 508297-001 CSR Mandatory Optional - Mandatory Mandatory Mandatory Mandatory Mandatory HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide 57 - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 58
3.5 12-drive enclosure exploded view Table 13 MSA2000 3.5 12-drive enclosure parts list Item Description Spares part number 1 SPS-BLANK,HDD 2 Hard drives a) SPS-DRV, HD 146GB MSA2 3.5" 15K DP SAS b) SPS-DRV, - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 59
this product, see the warranty information website at http://www.hp.com/go/storagewarranty. • To order a replacement part, contact an HP-authorized service provider or see the HP Parts Store online at http://www.hp.com/buy/parts. HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide 59 - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 60
60 Parts catalog - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 61
codes and regulations at the facility site. Follow all cautions and instructions marked on the equipment. Site requirements and guidelines The following sections circuit breakers must provide sufficient power and overload protection. HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide 61 - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 62
which you might move the rack can support the weight. To prevent accidents when moving computer systems. Ventilation requirements Refer to Environmental requirements for detailed an enclosure to allow access to enclosure components for servicing. Removing a component requires a clearance of at least - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 63
strong enough to support the combined weight for installation, operation, and servicing the enclosures, and also Modular Smart Array • SAS drives • SATA drives 2324fc Modular Smart Array • SAS drives • SATA drives MSA2000 -sine HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide 63 - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 64
Electrical requirements Site wiring and power requirements Each enclosure has two power and cooling modules for redundancy. If full redundancy is required, use a separate power source for each module. The AC power supply unit in each power and cooling module is auto-ranging and is automatically - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 65
on conductive floors or dissipating floor mats. • Use conductive field service tools. • Use a portable field service kit with a folding static-dissipating work mat. If you do with product installation, contact an authorized reseller. HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide 65 - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 66
66 Electrostatic discharge - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 67
instructions for device is determined, refer to the following hp.com. For questions regarding this FCC declaration, contact us by mail or telephone: • Hewlett-Packard Company P.O. Box 692000, Mailstop 510101 Houston, Texas 77269-2000 HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 68
When requesting compliance information for this product, always refer to this RMN. The Regulatory Model Number should array is located behind the left ear on the side of the chassis. Laser device All HP those specified herein. • Allow only HP authorized service technicians to repair the laser device. - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 69
issued by Hewlett-Packard for this product or product family. This compliance is indicated by the following conformity marking hp.com/go/certificates. Hewlett-Packard GmbH, HQ-TRE, Herrenberger Strasse 140, 71034 Boeblingen, Germany HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 70
is a danger of explosion and risk of personal injury if the battery is incorrectly replaced or mistreated. Replacement is to be done by an HP authorized service provider using the HP spare part designated for this product. For more information about battery replacement or proper disposal, contact an - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 71
(12 ft). If you have questions about the type of power cord to use, contact an HP authorized service provider. Route power cords so that they will not be walked on and cannot be pinched by storing products in static-safe containers. HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide 71 - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 72
tools. • Use a portable field service kit with a folding static-dissipating work mat. If you do not have any of the suggested equipment for proper grounding, have an HP authorized reseller install the part. NOTE: For more information on static electricity, or assistance with product installation - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 73
troubleshooting 43 ESD (electrostatic discharge) prevention measures 71 storing products 71 transporting products 71 Ethernet cables requirements 28 European Union, regulatory compliance notice 69 expansion port LED troubleshooting 50 HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 74
Federal Communications Commission See FCC firmware checking versions 29 when to HP address for FCC questions 67 series number 68 storage web site 13 Subscriber's choice web site 13 technical support 27 MSA2000 3.5 12-drive enclosure LEDs 36 ports 19 MSA2000 Family SCSI Enclosure Services (SES - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 75
MSA2000 number, regulatory compliance 68 service port 18, 19, support, HP 12 telephone numbers FCC questions 67 temperature operating range 63 toe straps, using 72 tools, conductive type 72 transportable CompactFlash 19 troubleshooting HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide 75 - HP StorageWorks 2000fc | HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 76
W warnings lasers, radiation 68 rack stability 12 voltage and temperature 50 web sites HP documentation 11 HP storage 13 HP Subscriber's choice 13 web-browser configuration 39 work mat, static-dissipating 72 wrist straps specifications 72 using 72 76
HP StorageWorks