- HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 1
Fabric OS Command Reference Manual Supporting Fabric OS v5.2.0 Publication Number: 53-1000240-01 Publication Date: 09/29/2006 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 2
http://www.brocade.com/support/oscd. Export of technical data contained in this document may require an export license from the United States government. Brocade Communications Systems, Incorporated Corporate Headquarters Brocade Communications Systems, Inc. 1745 Technology Drive San Jose, CA - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 3
. A Manual September 1999 May 2000 December 2000 July 2001 December 2001 March 2002 September 2002 April 2003 April 2003 May 2003 July 2003 August 2003 October 2003 Excluding edits and commands updated to support the SilkWorm 3250, 3850, and 24000 switches, added 3 commands, changed 20 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 4
Manual Fabric OS Command Reference 53-0000519-10 Manual Fabric OS Command Reference 53-0000519-12 Manual Fabric OS Command Reference 53-1000240-01 Manual Add 14, modify 128 "Fabric OS Commands," content to Structured FrameMaker format to support XML delivery of command content (due to this process - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 5
Fabric OS Commands aaaConfig 2-2 ad 2-4 agshow 2-14 agtCfgDefault 2-16 agtCfgSet 2-19 agtCfgShow 2-22 aliAdd 2-25 aliCreate 2-26 32 authUtil 2-33 backplaneTest 2-35 backport 2-37 bannerSet 2-39 bannerShow 2-40 bcastShow 2-41 bladeBeacon 2-42 Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 6
59 cfgDelete 2-60 cfgDisable 2-61 cfgEnable 2-62 cfgRemove 2-63 cfgSave 2-64 cfgShow 2-65 cfgSize 2-68 cfgTransAbort 2-70 cfgTransShow 2-71 chassisConfig 2-72 configDownload 2-86 configShow 2-90 configUpload 2-93 vi Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 7
2-119 diagEnablePost 2-120 diagEnv 2-121 diagFailLimit 2-123 diagHelp 2-124 diagLoopId 2-125 diagModeShow 2-126 diagPost 2-127 diagRetry 2-128 diagSetBurnin 2-129 diagSetCycle 2-130 diagShow 2-131 diagShowTime 2-132 diagSkipTests 2-133 diagStatus 2-134 diagStopBurnin 2-135 distribute - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 8
fastboot 2-170 fazoneAdd 2-171 fazoneCreate 2-172 fazoneDelete 2-174 fazoneRemove 2-175 fazoneShow 2-176 fcipChipTest 2-177 fcipPathTest 2-179 fcLunQuery 2-181 fcPing 2-182 viii Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 9
211 fdmiCacheShow 2-213 fdmiShow 2-214 ficonClear 2-215 ficoncupset 2-216 ficoncupshow 2-217 ficonHelp 2-218 ficonShow 2-219 filterTest 2-225 firmwareCommit 2-227 firmwareDownload 2-228 firmwareDownloadStatus 2-232 Fabric OS Command Reference Manual ix Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 10
h 2-264 haDisable 2-265 haDump 2-266 haEnable 2-268 haFailover 2-269 haShow 2-270 haSyncStart 2-272 haSyncStop 2-273 help 2-274 historyLastShow 2-275 historyMode 2-276 x Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 11
2-317 itemList 2-319 killTelnet 2-321 licenseAdd 2-323 licenseHelp 2-324 licenseIdShow 2-325 licenseRemove 2-326 licenseShow 2-327 linkCost 2-328 login 2-330 logout 2-331 Fabric OS Command Reference Manual xi Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 12
nsAllShow 2-368 nscamShow 2-369 nsShow 2-371 nsZoneMember 2-375 passwd 2-378 passwdCfg 2-381 pathInfo 2-385 pdShow 2-389 perfAddEEMonitor 2-390 perfAddIPMonitor 2-392 xii Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 13
2-421 pkiCreate 2-423 pkiRemove 2-424 pkiShow 2-425 policy 2-426 portAlpaShow 2-429 portBufferShow 2-430 portCamShow 2-433 portCfg 2-436 portCfgDefault 2-442 portCfgEPort 2-443 Fabric OS Command Reference Manual xiii Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 14
portLogDisable 2-480 portLogDump 2-481 portLogDumpPort 2-483 portLogEnable 2-484 portLogEventShow 2-485 portLoginShow 2-488 portLogPdisc 2-489 portLogReset 2-490 portLogResize 2-491 portLogShow 2-492 xiv Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 15
2-538 powerOffListShow 2-540 psShow 2-541 quietMode 2-542 reboot 2-543 routeHelp 2-544 saveCore 2-545 secActiveSize 2-549 secAuthSecret 2-550 secCertUtil 2-552 secDefineSize 2-556 Fabric OS Command Reference Manual xv Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 16
secTempPasswdSet 2-595 secTransAbort 2-596 secVersionReset 2-597 sensorShow 2-598 setDbg 2-599 setEsdMode 2-600 setGbicMode 2-601 setMediaMode 2-602 setModem 2-603 setSfpMode 2-605 xvi Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 17
2-650 supportSave 2-652 supportShow 2-655 supportShowCfgDisable 2-661 supportShowCfgEnable 2-662 supportShowCfgShow 2-663 switchBeacon 2-664 switchCfgPersistentDisable 2-665 switchCfgPersistentEnable 2-666 Fabric OS Command Reference Manual xvii Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 18
topologyShow 2-698 traceDump 2-700 traceFtp 2-701 trackChangesHelp 2-703 trackChangesSet 2-704 trackChangesShow 2-705 trunkDebug 2-706 trunkShow 2-707 tsClockServer 2-709 tsTimeZone 2-711 xviii Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 19
3-3 ISL Trunking Commands 3-4 Advanced Performance Monitoring Commands 3-4 Secure Fabric OS Commands 3-6 Exclusive Primary FCS Commands Commands Exclusive to the Primary FCS 4-1 Fabric OS Command Reference Manual xix Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 20
Commands Commands Supported on the Standby CP 5-1 Chapter 6 supportShow Reference supportShow Control Commands 6-1 supportShow Command Groups 6-2 Proc Entry Information Displayed 6-4 Appendix A RBAC Command Availability Index xx Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 21
manual written to help system administrators and technicians operate, maintain, and troubleshoot SAN products. "About This Document" contains the following sections: • "How This Document Is Organized," next • "Supported interface to manage a Brocade SAN and Brocade SilkWorm switches. • Chapter 2 , - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 22
4900 switch • Brocade SilkWorm 7500 switch • Brocade SilkWorm 24000 director • Brocade SilkWorm 48000 director In those instances in which procedures or parts of procedures documented here apply to some switches but not to others, this guide identifies exactly which switches are supported and - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 23
- iscsiCfg - iscsiChipTest - iscsiHelp - iscsiPathTest - iscsiPortCfg - iscsiSessionCfg - iscsiTargetName - isnscCfg - lsanZoneShow - passwdCfg - policy - portCfg - portCfgEXPort - portCfgNPIVPort - portCfgVEXPort Fabric OS Command Reference Manual xxiii Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 24
- Chapter 3, "MUA-Based Roles." The relevant content was moved to Chapter 1. For further information, please refer to the Release Notes. xxiv Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 25
narrative portions of this guide are presented in mixed you to potential damage to hardware, firmware, software, or data. Warning A SAN-specific terms, visit the Storage Networking Industry Association online dictionary at http://www.snia.org/education/dictionary. Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 26
and on the Brocade Web site, through Brocade Connect. Note Go to http://www.brocade.com and click Brocade Connect to register at no cost for a user ID and password. Fabric OS • Fabric OS Administrator's Guide • Fabric OS Command Reference Manual • Fabric OS MIB Reference Manual • Fabric OS Message - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 27
Mount Kit Installation Procedure • Mid-Mount Rack Kit Installation Procedure SilkWorm 7500 • SilkWorm 7500 Hardware Reference Manual • SilkWorm 7500 QuickStart Guide • SilkWorm 7500 Fan Assembly Replacement Procedure • SilkWorm Mid Sized Power Supply Replacement Procedure SilkWorm 4900 • SilkWorm - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 28
200E Hardware Reference Manual (for v5.x software) For practical discussions about SAN design, implementation, and maintenance, you can obtain Building SANs with Brocade Fabric Switches through: http://www.amazon.com For additional Brocade documentation, visit the Brocade SAN Info Center and - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 29
leave the tunnel. Fabric OS supports eight FCIP interswitch links between two SilkWorm switches (SilkWorm 7500 or SilkWorm 48000 with a FR4-18i blade) or routes. All 16 links can be used as FCIP http://www.fibrechannel.org Fabric OS Command Reference Manual xxix Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 30
Information • Technical Support contract number, if applicable • Switch model • Switch operating system version • Error numbers and messages received • supportSave command output • Detailed description of the problem and specific questions • Description of any troubleshooting steps already performed - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 31
Feedback Because quality is our first concern at Brocade, we have made every effort to ensure the topic needs further development, we want to hear from you. Forward your feedback to: [email protected] Provide the title and version number and as much detail as possible about your issue, - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 32
xxxii Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 33
SAN and Brocade SilkWorm switches and directors using the Fabric OS command line interface (CLI). The following information is discussed: • "Understanding Role-Based Access Control" on page 1-1 • "Using the Command Line Interface" on page 1-2 Refer to Fabric OS Administrator's Guide for information - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 34
. Access is controlled by a switch-level password for each access level. The commands available through the CLI are based on the user's login role and the license keys used to unlock certain features. Fabric OS CLI is the complete fabric management tool for Brocade SANs, providing: • Access to the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 35
Fabric OS Commands Chapter 2 Fabric OS Command Reference Manual 2-1 Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 36
all switch instances in a platform supporting multiple switch domains. Customers can use centralized RADIUS servers to manage AAA services for a switch, as RADIUS configuration list, with port as the RADIUS server port number, secret as the shared secret between the switch and the RADIUS server, - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 37
AAA service. service and the switch-local database as the secondary AAA service. When enabled, if RADIUS authentication fails, the switch-local database will be accessed for AAA services Service: Switch database Secondary AAA Service: None To change the configuration for server 192.168.233.48: switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 38
, the changes in the transaction buffer are sent to all other switches and saved to the Defined configuration (in persistent storage). For set the default zone mode to "No Access": switch:admin> ad --select AD0 switch:admin> defzone --noaccess switch:admin> cfgsave All switches, switch ports and - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 39
: D,PI Uses existing zone D,PI member types. Benefits include: • Grants port control and zoning on the switch port and the devices attached to that port. • PI can be specified as a range; for example, D,[0-34]. The port index range is expanded and stored internally. • Same D,PI members can be - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 40
Supports node or port switches in an Admin Domain, in quotation marks. Separate each entry in the switch list with a semicolon (;). Specify the switch in one of the following formats: • Switch WWN • Domain ID Note Any switch switch implicitly provides port control capability on all its ports default, - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 41
the defined configuration and enforces the defined configuration on all switches in the fabric. ad --apply prompts for confirmation. -- on AD0. ad --deactivate does not result in any port disables. All existing user sessions to a deactivated Admin Domain Manual 2-7 Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 42
defined configuration in all the switches in the fabric. The Domain members are from a non-Admin Domain aware switch or if the members do not exist in the members that are from non-Admin Domain aware switches and members that are not online are phantom switch WWNs specified in AD's switch memberlist - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 43
pre-v3.2 Fabric OS. This is because pre-v3.2 Fabric OS does not support Exchange Service Support (ESS), and therefore the Name Server cannot get the correct port range of such switches. --transabort --transshow Aborts the transaction buffer. ad --transabort prompts for confirmation before aborting - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 44
for readability. ad To create an Admin Domain with both device and switch list: switch:admin> ad --create "AD1", -d "100,5; 1,3; 21:20:00:00:e0:8b:05:4d:05" -s "100; 10:00:00:60:69:80:59:13" To deactivate Admin Domain 5: switch:admin> ad --deactivate 5 You are about to deactivate an AD. This - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 45
Switch port members: Switch WWN members: Effective configuration AD: 1 : AD1 Active Device WWN members: Switch port members: Switch :00:02:53; To display the AD1 configuration information in the transaction buffer: switch:admin> ad --show 1 -m 0 Current AD: 255 : AD255 Transaction buffer - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 46
Device WWN members: Switch port members: Switch WWN members: 21:00:00:80:e5:12:8b:37; 21:00:00:80:e5:12:8b:55; 1,0; 1,1; 1,2; 1,3; 1,4; 1,5; 1,6; 1,7; 1,8; 1,9; 1,10; 1,11; 1,12; 1,13; 1,14; 1,15; 10:00:00:60:69:00:02:53; 2-12 Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 47
AD1 Active Switch port members: AD: 2 : AD2 Active 1,0; 1,1; 1,2; 1,3; 1,4; 1,5; 2,0**; 2,1**; 2,2**; 2,3**; 2,4**; 2,5**; Switch port members: current Admin Domain transaction: switch:admin> ad --transshow Current transaction token is 26816 It is abortable switch:admin> ad --transshow There - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 48
the Access Gateway. Ports The number of ports in the Access Gateway. Enet IP Addr The IP address of the Access Gateway. Firmware The version of the Access Gateway firmware running on Access registered Access Gateways. 2-14 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 49
:00:00:00:c9:3f:7c:b9 To display the locally registered Access Gateways: switch:admin> agshow --local Name Ports Enet IP Addr Firmware Local/Remote WT_Stealth 16 10.202.90.231 v1.0.0 local See Also portCfgNPIVPort Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-15 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 50
switch. This command resets the following values: sysDescr The system (switch) description. The default value is "Fibre Channel Switch" on most platforms; however, the default Domain restrictions that may be in place. 2-16 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 51
IP octets. For example, an ACL of 192.168.64.0 enables access by any hosts that start with the specified reset the SNMP agent to default values: switch:admin> agtcfgdefault ***** This command will reset the agent's configuration back to factory default Manual Publication Number: 53-1000240-01 2-17 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 52
0: Access host subnet area 192.168.64.0 (rw)] Entry 1: No access host reset to factory default Current SNMP Agent Configuration Customizable MIB-II system variables: sysDescr = Fibre Channel Switch. sysLocation = End User Premise sysContact = Field Support Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 53
this command to modify the configuration of the SNMP agent in the switch. All values successfully configured by this command take effect immediately. These for the system. The default value is "Field Support". Refer to the Fabric OS MIB Reference Manual for detailed sysDescr, sysLocation, - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 54
octets. For example, an ACL of 192.168.64.0 enables access by any hosts that start with off when all six entries contain 0.0.0.0. The default values of all six entries are 0.0.0.0. Note When switch only and will propagate across the fabric. Operands none 2-20 Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 55
SNMP configuration values: switch:admin> agtcfgset Customizing Switch] sysLocation: [End User Premise] sysContact: [Field Support dot notation: [0.0.0.0] 192.168.64.88 Trap recipient Severity level in dot notation: [0.0.0.0] 192.168.64.0 Read/Write? (true, t, Switch Management Information & Switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 56
The system (switch) description. The default value is "Fibre Channel Switch". sysLocation The location of the system. The default value is "End User Premise". sysContact The contact information for the system. The default value is "Field Support". Refer to the Fabric OS MIB Reference Manual for - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 57
nonzero IP octets. For example, an ACL of 192.168.64.0 enables access by any hosts that start with the specified is turned off when all six entries contain 0.0.0.0. The default values of all six entries are 0.0.0.0. Note When secure FCS switch only and will propagate changes across the fabric - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 58
subnet area 192.168.64.0 (rw)] Entry 1: Switch Management Information & Switch Enterprise Specific Trap", RFC1157, "A Simple Network Management Protocol (SNMPv1)", RFC1213, "Management information Base for Network Management of TCP/IP-based Internets: MIBII" 2-24 Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 59
pair. View the area numbers for ports using the switchShow command. • WWN • QuickLoop AL_PAs To add members to zone aliases array1, array2, and loop1: switch:admin> aliadd "array1", "1,2" switch:admin> aliadd "array2", "21:00:00:20:37:0c:72:51" switch:admin> aliadd "loop1", "4,5[0x02]; 6,7[0xEF - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 60
pair. View the area numbers for ports using the switchShow command. • WWN • QuickLoop AL_PAs To create a zone alias: switch:admin> alicreate "array1", "2,32; 2,33; 2,34" switch:admin> alicreate "array2", "21:00:00:20:37:0c:66:23" switch:admin> alicreate "loop1", "4,5[0x02]; 6,7[0xEF]; 5,4" See - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 61
a Brocade Advanced Zoning license. When secure mode is enabled, this command can be issued only from the primary FCS switch. Operands the zone alias array2: switch:admin> alidelete "array2" See Also aliAdd, aliCreate, aliRemove, aliShow Fabric OS Command Reference Manual Publication Number: 53- - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 62
a World Wide Name from "array1": switch:admin> aliremove "array1", "3,5" switch:admin> aliremove "array1", "21:00:00:20:37:0c:76:8c" switch:admin> aliremove "array1", "0xEF" See Also aliAdd, aliCreate, aliDelete, aliShow 2-28 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 63
can be issued only from the primary FCS switch. Operands Examples This command has the following the contents of the nonvolatile memory. The default value is 0. If no parameters are specified arr": switch:admin> alishow "arr*" alias: array1 21:00:00:20:37:0c:76:8c alias: array2 21:00:00:20:37:0c - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 64
manual. The default parameters are optimal for most SAN applications; typical customers do not need to use this command. When used with no arguments, this command displays a list of APT policies supported on this switch paths. All frames received on a ingress port with the same (SID, DID, OXID) - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 65
1 Policy updated successfully. switch:admin> switchenable switch:admin> aptpolicy Current Policy: 1 3: Default Policy 1: Port Based Routing Policy 3: Exchange Based Routing Policy See Also dlsReset, dlsSet, dlsShow, switchDisable Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 66
CONFIGURATION, 4-FIRMWARE and 5FABRIC switch:admin> auditcfg --class 2,3 Audit filter is configured. switch:admin> auditcfg --disable Audit filter is disabled. switch:admin> auditcfg --show Audit filter is disabled. 2-SECURITY 3-CONFIGURATION See Also none 2-32 Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 67
switch default setting of "fcap, dhchap" is used. When no group is set, the default switch. Use portShow to display the authentication type and associated parameters, if applicable, used on the port at port DH-CHAP (default). When CHAP on the local switch; however a responder switch: switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 68
--set -g 3 DH Group was set to 3. To set all DH groups to be specified in auth negotiate in order of 0, 1, 2, 3, and 4: switch:admin> authutil --set -g "*" DH Group is set to 0,1,2,3,4 See Also portShow, secAuthSecret 2-34 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 69
nonzero value, this mode displays the test progress in detail. The default value is to disable the mode. To test backplane connections on a SilkWorm director: switch:admin> backplanetest -ports 1/16, 18, 20 -payload 2048 -verbose 1 Running backplanetest Test frame info for Backplane Connection - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 70
the following error messages: • DATA • TIMEOUT • XMIT Refer to the Fabric OS Message Reference for more information. See Also itemList 2-36 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 71
is not tested if -extonly is set to 1. This command is supported only on SilkWorm 3250, 3850, 3900,4100, and 24000 platforms. Note -ports itemlist Specifies a list of user ports. The default value is all user ports. Refer to itemList for more information. Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 72
for the test. By default, backport uses internal loopback. Mode Description 1 Port loopback (loopback plugs) link. To test for backend ASIC pair links: switch:admin> backport -ports 1/1-1/3 -nframes 840 One moment please ... backport running Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 73
"My banner" switch:admin> bannerSet Please input context of security banner (press "." RETURN at the beginning of a newline to finish input): Do not log into this switch if you are not an authorized administrator. . See Also bannerShow Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 74
of this command is subject to Admin Domain restrictions that may be in place. Operands Examples none To display the banner for a switch: switch:admin> bannershow Banner: Do not log into this switch if you are not an authorized administrator. See Also bannerSet 2-40 Fabric OS Command Reference - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 75
this example, from a switch with 128 ports, the member ports consist of ports 7, 13, 42, 84, 85, and 86. The final Member Ports bit set represents the embedded port (frames sent to be handled by firmware) and is typically set. portRouteShow Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 76
can be used to locate a physical unit. Beaconing mode only takes over the port LEDs; it does not change the switch's functional behavior. The normal flashing LED pattern (associated with an active, faulty, or disabled port, for example) is suppressed and only the beaconing pattern is displayed. If - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 77
change to slow flashing yellow as each port of the blade disables. Note A blade cannot be disabled or enabled when the switch is disabled or when the blade itself See Also bladeEnable, portDisable, portEnable, switchShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-43 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 78
they might come online if connected to a device or remain offline if disconnected. If the switch is connected to a fabric through previously disabled ports, it rejoins the fabric. If this switch remains the principal switch at the end of the fabric countdown, then it assigns itself a domain ID. If - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 79
2 Examples To display the slot status, enable the user ports in slot 4, and verify the setting: switch:admin> slotshow Slot Blade Type ID Status 1 SW BLADE See Also bladeDisable, portDisable, portEnable, switchShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-45 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 80
operand is a follows: slotnumber A nonzero value that specifies the slot number from which to clear burn-in errors. To clear burn-in errors from slot 2. switch:admin> burninerrclear 2 See Also burninErrShow 2-46 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 81
as follows: slotnumber A nonzero value that specifies the slot number from which to display burn-in errors. Examples To display burn-in errors from slot 2: switch:admin> burninerrshow 2 See Also burninErrClear Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-47 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 82
power-on self-test (POST) phase II each time a switch blade is powered on. The mode becomes active as soon preserves the errors prior to returning a board for service. For multibladed products, this is the independent set the diagnostic burn-in level: switch:admin> burninlevel -show Burnin level - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 83
all slots are displayed. Examples To display the burn-in status for all slots: switch:admin> burninstatus Slot State Status Run 1 ABORT PASS 3 2 ABORT PASS 3 3 burnin burnin burnin To display the burn-in status for slot 3: switch:admin> burninstatus --slot 3 Slot State Status Run Cmd 3 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 84
an enabled switch. You must first disable the switch using the switchDisable command. This command is supported only on ports to test. By default, all the blade ports in the specified slot (--slot) will be used. Refer to itemList for more information. To verify CAM is functioning correctly: switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 85
Refer to the Fabric OS Message Reference for more information. See Also centralMemoryTest, cmemRetentionTest, cmiTest, crossPortTest, itemList, portLoopbackTest, portRegTest, spinSilk, sramRetentionTest Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-51 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 86
BIST is executed again. The firmware sets up the hardware for the default pattern used (by POST also) is a QUAD_RAMP with a seed value of 0. ASIC-to-ASIC Connection Subtest Note This subtest is not available on 2 Gbit/sec-capable switches. The ASIC-to-ASIC connection subtest verifies that any port - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 87
of data includes a bad buffer. 3. For each of the 11 possible offsets for each ASIC X in the switch: a. Write a 64-byte pattern in the central memory. b. Read X from all ASIC Y in the switch. c. For ASIC X, ensure: Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 88
before the test is run. By default, all the blade ports in the specified slot (--slot) are tested. Refer to itemList for more information. -seed value Specify the data pattern seed to be used. The default seed value is 0. 2-54 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 89
. centralMemoryTest 2 Examples To test the ASIC central memory: switch:admin> centralmemorytest -ports 1/0-1/15 Running centralmemorytest Test Complete: centralmemorytest Pass 1 of , spinSilk, sramRetentionTest Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-55 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 90
configuration is built when a specified zone configuration is enabled. Note This command requires a Brocade Advanced Zoning license. When security is enabled, this command can be issued on any switch in the fabric. Operands Examples none To display the effective zone configuration information - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 91
. For the change to be preserved across switch reboots, it must be saved to nonvolatile Brocade Advanced Zoning license. When security is enabled, this command can be issued only from the primary FCS switch new zones to the configuration "Test_cfg": switch:admin> cfgadd "Test_cfg", "redzone; - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 92
the default zoning objects. Note This command requires a Brocade Advanced Zoning license. When security is enabled, this command can be issued only from the primary FCS switch. n See Also cfgDisable, cfgEnable, cfgSave 2-58 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 93
. For the change to be preserved across switch reboots, it must be saved to nonvolatile Brocade Advanced Zoning license. When security is enabled, this command can be issued only from the primary FCS switch create a configuration containing three zones: switch:admin> cfgcreate "USA_cfg", "Red_zone; - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 94
For the change to be preserved across switch reboots, it must be saved to nonvolatile Brocade Advanced Zoning license. When security is enabled, this command can be issued only from the primary FCS switch required. To delete a zone configuration: switch:admin> cfgdelete "USA_cfg" See Also cfgAdd - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 95
aborted. A message is displayed on the other switches to indicate the aborting of the transaction. If the default zone access mode is "No Access", then this command becomes cfgEnable "d_efault_Cfg". See defZone. Note This command requires a Brocade Advanced Zoning license. When security is enabled - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 96
command requires a Brocade Advanced Zoning license. When security is enabled, this command can be issued only from the primary FCS switch. Operands Examples This flash ... See Also cfgClear, cfgDisable, cfgSave, cfgShow 2-62 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 97
. For the change to be preserved across switch reboots, it must be saved to nonvolatile Brocade Advanced Zoning license. When security is enabled, this command can be issued only from the primary FCS switch To remove a zone from a configuration: switch:admin> cfgremove "Test_cfg", "redzone" See - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 98
switch is automatically aborted. A message is displayed on the other switches to indicate the aborting of the transaction. Note This command requires a Brocade , cfgEnable, cfgRemove, cfgShow, cfgTransAbort, cfgTransShow 2-64 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 99
and all error checking has been completed successfully. When default zoning is enabled with "No Access" mode, " requires a Brocade Advanced Zoning license. When security is enabled, this command can be issued on any FCS switch in the OS Command Reference Manual Publication Number: 53-1000240-01 2-65 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 100
2 Note: Enter commands in lowercase only; mixed case is for readability. cfgShow must be enclosed in brackets: for example, [0-9] or [a-f]. 2-66 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 101
20:37:0c:71:df To display only configuration names: switch:admin> cfgshow "*" cfg: USA1 Blue_zone cfg: USA_cfg Red_zone; Blue_zone See Also cfgAdd, cfgClear, cfgCreate, cfgDelete, cfgDisable, cfgEnable, cfgRemove, cfgSave, cfgTransAbort, cfgTransShow Fabric OS Command Reference Manual Publication - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 102
propagated with the zone configuration to all switches in the fabric. Committed size is the Brocade Advanced Zoning license. When security is enabled, this command can be issued only from the primary FCS switch information in non-AD255 context: switch:admin> cfgsize Zone DB max size - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 103
Domain and zone database information in AD255 context: switch:admin> cfgsize Maximum AD and Zone DB max 0 bytes Zone CFG Info for AD Number: 1 (AD Name: ad1): committed - 16 bytes transaction - 0 bytes Zone CFG Info for AD Number: 2 (AD Name: Reference Manual Publication Number: 53-1000240-01 2-69 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 104
switch in the fabric when this command is run, the transaction on the other switch remains open and unaffected. Note This command requires a Brocade Advanced ID of a transaction. To abort the current transaction: switch:admin> cfgtransabort See Also cfgAdd, cfgClear, cfgCreate, cfgDelete, - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 105
internal zoning transaction. Note This command requires a Brocade Advanced Zoning license. When security is enabled, this command can be issued only from the primary FCS switch. Operands Examples none To display the current transaction: switch:admin> cfgtransshow There is no outstanding zone - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 106
and SilkWorm 48000 directors support options 1 and 5: 1 One 128-port switch (blade ID 4, 17 on slots 1 - 4 and 7 - 10; blade ID 5, 16 on slots 5 - 6) 2 Two 64-port switches (blade ID 4 on slots 1 - 4 and 7 - 10; blade ID 5 on slots 5 - 6) 5 One 384-port switch (Blade ID 17, 18, 24, 31, 36 in - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 107
created using the userConfig command are deleted and user accounts are reset to the factory default user accounts and passwords. Note The execution of this command is subject to Admin Domain and a list of all valid options. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-73 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 108
chassisconfig Current Option: 5 All Supported Options (With Blade ID 5 on slots 5-6 Option 1: One 128-port switch (Blade ID 4, 17 on slots 1-4, 7-10, Blade ID 5, 16 on slots 5-6) Option 5: One 384-port switches (Blade ID's 17, 18, 24, 31, 36 in slots 1-4, 7-1, Blade ID 16 in slots 5-6) Please use - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 109
, the current chassis name displays. Examples To change the chassis name to "dilbert": switch:admin> chassisname dilbert Please wait while committing configuration... switch:admin> chassisname dilbert See Also switchName Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-75 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 110
hexadecimal. 2 Object type: CHASSIS, FAN, POWER SUPPLY, SW BLADE (switch), CP BLADE (control processor), WWN (World Wide Name), or UNKNOWN. up to 20 characters): Part Num: xxxxxxxxxxxxxxxxxxxx 13 Externally supplied serial number (up to 20 characters): Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 111
display all FRUs for a switch: switch:user> chassisshow Chassis Backplane 16 days 555-374757 238-298-12360 1234567 1 -50 20-123456-12 B014934500 Day: 6 Month: 7 Year: 2001 Day: 15 Month: 7 Year: 2001 88 days 16 days 456-777888 230-290-12370 (output truncated) Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 112
2 Note: Enter commands in lowercase only; mixed case is for readability. chassisShow See Also slotShow 2-78 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 113
support use only. The command is supported only default is set to 0 and designed to operate on fixed-port-count products. filter Specifies a filter string. To display the port registers of a chip: switch:admin> chipregshow 1/1 ffffffff See Also minisPropShow Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 114
00000001 00000002 00000003 RANDOM 11 55 16 fc d7 17 65 a9 87 5f 44 be 5a d0 de bc a5 -ports itemlist Specify a list of blade ports to test. The ports list is translated into a matching quad list before the test is run. By default, all the blade ports in the specified slot (--slot) are - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 115
run the data-retention test on the central memory SRAMS: switch:admin> cmemretentiontest --slot 7 Running cmemretentiontest Test Complete: 0 hr, 1 min & 33 sec (0:1:33:16). passed. Diagnostics The following are possible error messages OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 116
default, all the ports in the specified slot (--slot) are used. Refer to itemList for more information. -skip mask Specifies tests to skip using a bit map as follows: 1 CMI data test (ignore checksum) 2 CMI checksum test 3 Enable all tests To run a CMI test between two ASIC pairs: switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 117
-INTNIL Refer to the Fabric OS Message Reference for more information. See Also camTest, centralMemoryTest, cmemRetentionTest, crossPortTest, itemList, portLoopbackTest, spinSilk, sramRetentionTest Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-83 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 118
• System name • Chassis name • World Wide Name • Brocade Advanced Zoning configuration (includes aliases, zones and configurations) • Security parameters and policies • User account passwords (includes all user config and all built-in accounts) • Switch PID format • Ethernet Link Mode Note Refer to - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 119
commands in lowercase only; mixed case is for readability. configDefault 2 Examples To restore the system configuration to default values: switch:admin> configdefault Committing Configuration ...done. See Also agtCfgDefault, configure, switchDisable, switchEnable Fabric OS Command Reference - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 120
password if necessary. The SSH service is also available on Unix and Windows hosts. For Admin Domain users, please refer to the Fabric OS Administrator's Guide to disable the switch before proceeding). • The host name is not known to the switch. • The host Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 121
Note [License] is only accepted if the boot.mac parameter matches the licenseid (WWN) of the switch performing the download; otherwise, it is ignored. Note The download process is additive. The lines read may be in place. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-87 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 122
If a protocol is not specified, FTP is the default. "host" Specifies a host name or IP address password for the FTP login. To download a configuration file interactively, on an AD-aware switch running Fabric OS v5.2.0: switch Password: ******** Activating configDownload without disabling switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 123
Password: *** CAUTION *** This command is used to download a backed-up configuration for a specific switch. If using a file from a different switch, switch:admin> switchenable switch:admin> See Also configDefault, configShow, configUpload, configure Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 124
of wildcards and other common regular expression operators is not supported. Some configuration settings will not display selectively in this manner configuration settings for "passwdcfg": switch:admin> configshow "passwdcfg" passwdcfg Fabric OS Command Reference Manual Publication Number: 53- - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 125
:2 fabric.ididmode:0 fabric.ops.BBCredit:16 fabric.ops.E_D_TOV:2000 fabric.ops.R_A_TOV:10000 fabric.ops.dataFieldSize:2112 fabric.ops.max_hops:7 fabric.ops.mode.fcpProbeDisable:0 fabric.ops.mode.isolate:0 (continued on next page) Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 126
fc4.fcp.productId:FC Switch fc4.fcp.vendorId:BROCADE fcAL.alwaysSendRSCN:0 fcAL.fanFrameDisable:0 port:80 http.ssl.enabled:0 http.ssl.port:443 http.ssllog.enabled:0 http.switchexplorer.isMainRightFrameEnabled:1 lcdContrast:128 92 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 127
will prompt for the password if necessary. The SSH service is also available on Unix and Windows hosts. This command can be invoked without any operands, creating an interactive session. The upload might fail for the following reasons: • The host name is not known to the switch. • The host IP - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 128
general switch configuration to the Fabric OS Administrator's Guide for details regarding configUpload and If a protocol is not specified, FTP is the default. "host" Specifies a host name or IP address on Windows hosts. "passwd" Specifies the password for the FTP login. Note No spaces - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 129
is for readability. configUpload 2 Examples To upload a configuration file interactively: switch:admin> configupload Protocol (scp or ftp) [ftp]: ftp Server Name [user]: jdoe File Name [config.txt]: config.txt Password: ******** configUpload complete: All config parameters except AD Headers,SFOS - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 130
"System Services Settings" • "Portlog Events Enable/Disable Settings" • "Application Attributes" Note If executed on an enabled switch, only a series of hierarchical menus. Each top-level menu and its associated submenus consist of a text prompt, a list of acceptable values, and a default value - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 131
Switch Fabric Settings are as follows: Table 2-3 Configure Command Fabric Parameters Field Type Default Domain number 1 R_A_TOV number 10000 E_D_TOV number 2000 out clock resets and waits port from any source port across the fabric. Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 132
each parameter. To reduce problems, the configuration utility default, the switch can send Class F frames. When this option is turned on, Class F traffic is converted to Class 2 traffic before being transmitted. Switch PID Format The formats are as follows: 0 Native PID Format (16 based, 16 port - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 133
will be segmented. Note A Brocade Extended Fabrics license is required to ports in the switch. Table 2-5 F_Port Login Parameters Field Type Default Range Maximum logins per switch Number 15*ports 1 to 126*ports Maximum logins per port Number 126 1 to 255 Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 134
Modes Field End-device RSCN Transmission Mode Domain RSCN to End-device for switch IP address or name change Type number number Default 1 0 Range 0 to 2 0 to 1 End-device RSCN Transmission Mode set to 0, frames are not sent. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 135
is supported by a number of operating systems that support RPC. On most UNIX-based systems (HP-UX, switch, you can disable the telnet interface for greater security. The default value is on (telnet enabled). Portlog Events Enable/Disable Settings Port events can be disabled from logging. The default - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 136
HTTP, SNMP, and RPCd attributes are configurable; by default, all three attributes are enabled. Refer to the table File string not set varies Length of crypto key number 128 40, 56, 128 http HTTP Enabled boolean Yes Yes/No Secure HTTP Enabled Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 137
2000] 5000 WAN_TOV: (0..30000) [0] 0 MAX_HOPS: (7..19) [7] Data field size: (256..2112) [2112] Sequence Level Switching: (0..1) [0] 1 Disable Device Probing: (0..1) [0] Switch PID Format: (1..2) [1] Per-frame Route Priority: (0..1) [0] BB credit: (1..16) [16 ?: (0..1) [0] System services(yes, y, no, - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 138
switch start or re-start event ) (on, off): [on] disable(a port is disabled ) (on, off): [on] enable(a port is enabled ) (on, off): [on] ioctl(a port ) switch(switch driver log ) ficonq(ficon queue and ELS measurements ) routing(switch/blade drivers Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 139
switch by sending frames from port M's transmitter and looping them back through an external fiber cable into port N's receiver, thus exercising all the switch received at any one time. The port LEDs flicker green while the test is running. Note The command is supported only on SilkWorm 200E,3250, - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 140
that are cable loopbacked to ports in the same switch are tested. Ports connected outside of the switch are ignored. To run the crossPortTest command successfully the test must find at least one port (-lb_mode = 1, this is the default) or two ports (-lb_mode = 0) cable loopbacked to each other. If - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 141
normally be left at the default value of 0. Specify a list of user ports to test. By default, all the user ports in the current switch will be used. Refer itemList, portLoopbackTest, portRegTest, spinSilk, sramRetentionTest Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-107 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 142
sample data streams you can use with diagnostics: switch:admin> datatypeshow Pattern BYTE_FILL WORD_FILL QUAD_FILL BYTE_NOT WORD_NOT type 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 example 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 143
port log. To enable secure mode the fabric must be synchronized. Every switch in the fabric must receive a fabric timestamp from the primary FCS switch. Use this command with no operands to display the local switch zone support. If the switch is operating are taken to indicate 2000-2069. Note The - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 144
only; mixed case is for readability. date Examples To display the current date and time and then modify it: switch:admin> date Fri Jan 29 17:01:48 UTC 2000 switch:admin> date "0227123003" Thu Feb 27 12:30:00 UTC 2003 See Also errShow, ficoncupset, ficoncupshow, portLogShow, tsClockServer - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 145
to view the debug and verbosity levels. Module names are case sensitive. This operand is optional. Examples To display information about a specific module named NS: switch:admin> dbgshow NS Module NS, debug level = 1, verbose level = 1 See Also setDbg Fabric OS Command Reference - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 146
command from a remote switch that does not support default zoning, zoning rejects the cfgDisable command in the second phase of RCS because the remote switch does not convert the cfgDisable command to a cfgEnable d_efault_Cfg command. 2-112 Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 147
Effective configuration: no configuration in effect switch:admin> defzone --noaccess switch:admin> cfgsave switch:admin> defzone --show Default Zone Access Mode committed - All Access transaction - No Transaction See Also none Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 148
:01" • aliCreate "d_efault_Zone_Alias", "1,0" Note This command requires a Brocade Advanced Zoning license. When security is enabled, this command can be issued only from the primary FCS switch. Names with the "d_efault" prefix are reserved for default zoning use. cfgShow shows the names of the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 149
Note: Enter commands in lowercase only; mixed case is for readability. defZoneCreate 2 See Also defZoneDelete Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-115 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 150
. Operands Examples None To delete a default zone configuration: switch:admin> cfgactvshow Effective configuration: no configuration in effect switch:admin> defzonedelete switch:admin> cfgactvshow See Also defZoneCreate 2-116 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 151
If no operand is specified, the default is to clear all bad port flags. To clear the diag software flag: switch:admin> diagclearerror 8 ERROR: DIAG CLEARERR Diagnostics Errors Cleared, port: 8/31 Err# 0120041 081F See Also none Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 152
chassis; however, the command is not supported by the SilkWorm platform and does not effect mini-switch ASIC property minisregshow display contents of mini-switch registers. ptbufshow dump port buffer contents (output truncated) See Also diagHelp 2-118 Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 153
command to disable POST. A reboot is not required for this command to take effect. Operands none Examples To disable the POST during future power ons: switch:admin> diagdisablepost Config update Succeeded Diagnostic POST is now disabled. See Also diagEnablePost Fabric OS Command Reference - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 154
of this command is subject to Admin Domain restrictions that may be in place. Operands Examples none To enable the POST during future power ons: switch:admin> diagenablepost Config update Succeeded Diagnostic POST is now enabled. See Also diagDisablePost 2-120 Fabric OS Command Reference - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 155
on the FR4-18i blade in a SilkWorm chassis; however, the command is not supported by the SilkWorm platform and does not effect any other feature operations. This availability is relevant diagnostic environment variable. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-121 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 156
only; mixed case is for readability. diagEnv Examples To display the values of the diagnostic parameters: switch:admin> diagshowusr Name Environment USR_DILATION DIAG_USR_DLY_DILATION USR_MEMDLY DIAG_USR_MEMDLY USR_SEED DIAG_USR_SEED USR_SPECIAL DIAG_USR_SPECIAL (output truncated) See - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 157
fail limit setting. If no operand is specified, the current value is displayed. Examples To change the fail limit from 1 to 5: switch:admin> diagfaillimit -show Fail Limit is 1. switch:admin> diagfaillimit 5 Fail Limit is now 5. Config update Succeeded See Also none Fabric OS Command Reference - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 158
default operands when running diagnostics commands. Nondefault settings require detailed knowledge of the underlying hardware and are intended for support personnel only. Contact support registers. dump port buffer contents See Also none 2-124 Fabric OS Command Reference Manual Publication Number: - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 159
loop ID to the corresponding AL_PA and used as the port address for any diagnostics that operate in FL_Port mode. The SilkWorm chassis; however, the command is not supported by the SilkWorm platform and does not effect any ID: switch:admin> diagloopid -show FL mode Loop ID is 125. - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 160
command is not supported by the SilkWorm diagnostic mode: switch:admin> diagmodeshow gbic diag.mode.splb diag.mode.lab diag.mode.mfg diag.mode.bplb diag.ports Burnin passnum Burnin nExec Silkworm Mode Disable Modes Print = 0 = 0 = Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 161
POST mode modifies the behavior of the diagnostics daemon program to inhibit testing of switch blades when the system is first powered on or a new blade is added then disable the POST test: switch:admin> diagpost Diagnostic POST is currently disabled. switch:admin> diagpost 1 Config update - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 162
display the current mode setting. If no operand is specified, the current value is displayed. To view the current retry mode value: switch:admin> diagretry -show Diagnostic Retry Mode is currently enabled. See Also none 2-128 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 163
of burn-in script to current burn-in script. To set the burn-in script and mode: switch:admin> diagsetburnin --slot 1 -current existing script is: /fabos/share/switchess.sh Burnin mode is burninErrShow, diagSetCycle Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-129 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 164
be specified manually in this case. To update diagnostic command parameters: switch:admin> diagsetcycle switchburnin.sh -show CURRENT - KEYWORD : DEFAULT 1 - 100 50 - txd_nframes : 50 200 - xpt_nframes : 200 20 - bpt_nframes : 20 50 - slk_nmegs : 50 30 - bpt_all_nframes: 30 50 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 165
ports specified in -uports displays. The default value is 0. Examples To display diagnostic status on a switch blade: switch:admin> diagshow Diagnostics Status: Fri Feb 08 15:25:24 2002 Slot: 1 UPORTS Port Also itemList Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-131 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 166
18i blade in a SilkWorm chassis; however, the command is not supported by the SilkWorm platform and does not effect any other feature is displayed. To enable show-time mode: switch:admin> diagshowtime Show Time mode is 0 (Disabled). switch:admin> diagshowtime 1 Config update Succeeded Show - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 167
given, the current skip test flags displays. If no operand is specified, the current value is displayed. Examples To display the current skip test flags: switch:admin> diagskiptests -show Skip tests is 1. See Also none Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-133 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 168
in a SilkWorm chassis; however, the command is not supported by the SilkWorm platform and does not effect any other are assumed. To display currently running diagnostic tests: switch:admin> diagstatus Diagnostic status for slot: 1. Diag OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 169
:18 Switch: 0, Error DIAG-MANUAL1, 1, " 1 Starting switchess ... Err# 0140042 0100:101:000:001:24:37: 0xc84 (fabos): Dec 20 08:57:27 Switch: 0, Switch: 0, Error DIAG-MANUAL1, 1, " 1 switchess: ABORT ... Err# 0140042 0100:101:000:002:26:41:1N See Also diagSetBurnin Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 170
To distribute the Switch Connection Control policy and Password database to all domains in the fabric that support the distribute feature: switch:admin> distribute -p "SCC;PWD" -d "*" Wildcard domains are: 1 3 5 See Also fddCfg 2-136 Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 171
the fabric cannot handle occasional routing changes correctly. DLS is not supported in certain routing policies. Refer to aptPolicy for more information on To disable the dynamic load sharing option: switch:admin> dlsreset Committing configuration...done. switch:admin> dlsshow DLS is not set See - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 172
port and the destination domain. This means that all the traffic coming in from a port setting of the DLS option, when ports come up, new routes are always option is on by default. Note DLS is not supported in certain routing policies sharing option: switch:admin> dlsset switch:admin> dlsshow DLS - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 173
to dlsSet for a description of load sharing. Note DLS is not supported in certain routing policies. Refer to aptPolicy for more information on routing DLS option setting: switch:admin> dlsshow DLS is set See Also dlsSet, dlsReset Fabric OS Command Reference Manual Publication Number: 53-1000240- - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 174
remove the domain name service parameters. The domain name service parameters are the domain parameters for the system: switch:admin> dnsconfig Enter option 1 Display Domain Name Service (DNS) configuration 2 Enter option 1 Display Domain Name Service (DNS) configuration 2 Set DNS configuration - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 175
attribute Description Use this command to display attributes of the switch enclosure. Currently, supported attributes are the vendor-specific enclosure identifier and the identifier of the enclosure interface to which the switch is attached. This command is only meaningful for the products - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 176
enclosure manager. connfuse Displays whether or not the switch has a fuse. To display the identifier of the enclosure interface to which the switch is attached: switch:admin> enclosureShow slotid Bay 4 See Also chassisShow 2-142 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 177
this command to clear all internal and external error log messages for all switch instances on this CP. Note The execution of this command is subject the error log messages: switch:admin> errclear See Also errDump, errShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-143 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 178
operand is optional. To display the start and end delimiter: switch:admin> errdelimiterset delimiter start string: delimiter end request from device 10:02:32:A3:78:23:23:End See Also errDump, errFilterSet, errShow 2-144 Fabric OS Command Reference Manual Publication Number: 53-1000240- - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 179
logs from Fabric OS versions prior to v4.2. Examples To display the error log, without pagination: switch:user> errdump Version: 4.4.0 2004/07/14-22:24:08, [HAMK-1003], 1,, INFO, switch1, Heartbeat up 2004/07/14-22:24:47, [FSSM-1002], 2,, INFO, switchChassis, HA State is in sync 2004/07/14-22:25 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 180
minimum severity level of the message to pass through the filter. Valid values are "INFO", "WARNING", "ERROR", or "CRITICAL". To display the current filter settings: switch:admin> errfilterset console: filter severity = WARNING To set the filter severity level for the console - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 181
may be in place. Operands Examples none To display a list of all defined error log modules: switch:user> errmoduleshow KT UT TRCE KTRC LOG CDR BLPU PISP PIXE EGR BL PIC PS RTE AS AUTH truncated) See Also errDump, errShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-147 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 182
display external error log messages for all switch instances and the chassis, one at include INFO, WARNING, ERROR, and CRITICAL. Switch name Switch name for the generator of this message, or is optional; if omitted, messages from all switch instances are displayed. -r Displays messages in reversed - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 183
pagination: switch:user> errshow Version: 4.4.0 2004/07/14-22:24:08, [HAMK-1003], 1,, INFO, switch1, Heartbeat up Type to continue, Q to stop: 2004/07/14-22:24:47, See Also errDelimiterSet, errDump, errFilterSet Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-149 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 184
. Telnet and rlogin connections are closed; the serial port returns to the login: prompt. The exit command is an accepted synonym for logout, as is typing Ctrl-D at the beginning of a line. Operands none Examples To exit from a shell session: switch:admin> exit Connection to host lost. See Also - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 185
to the fabric, as well as a list of pending commands. The following information displays: Port The port number. State The state of the port: P0 Port Offline P1 Port Online P2 ELP ACC Received P3 Link Reset Done I0 Trunk Initiator: EMT Sent I1 Trunk Initiator: ETP ACC Received I2 Trunk - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 186
RJT rcv 0x00200000 Received a DIA on this port 0x00400000 Port is the EMT Initiator 0x00800000 Security violation 0x01000000 Security incompatibility 0x02000000 Rcv a DIA ACC 0x040000000 Port is security authenticating 0x080000000 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 187
nbrPort lr_tid red_ports ECP RJT or retires exceeded 0x100000000 Segmented due to duplicated WWN 0x200000000 Segmented due to E_Port isolation Neighboring switch's WWN Neighboring switch's port Link reset timer identifier and current state. All E_Ports that are connected to the same neighboring - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 188
the fabric commands. The SW_ISL (ISL ports) information displays the retry count for the GRE Get Route Entry ECP Exchange Credit Parameters FWN Firmware Notification ???not in man page??? Note The of Fabric OS commands: switch:user> fabretryshow SW_ILS E_Port ELP EFP HA_EFP DIA RDI BF FWD - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 189
This command has the following operands: -s | --show Displays fabric log. -c | --clear Clears fabric log. -d | --disable Disables fabric log. By default, the fabric log is enabled. -e | --enable Enables fabric log. -r size | --resize size Changes the maximum number of log entries. The given - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 190
:08:52.977 *Cancel 24 * F_S_TOV Timer F2,NA 64 Warning: This command will clear the logs. Are your sure you want to do the resize [y/n]? y switch:admin> fabriclog -s Time Stamp Input and *Action S, P Sn,Pn Port Xid See Also fabPortShow, fabStatsShow 2-156 Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 191
> fabricprincipal 1 Principal Selection Mode enabled To enable the mode setting and force fabric rebuild: switch:admin> fabricprincipal -f 1 Principal Selection Mode enabled (Forcing fabric rebuild) See Also fabricShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-157 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 192
192.168.65.180 >"sw180" 66: fffc42 10:00:00:60:69:00:05:91 192.168.64.60 192.168.65.60 "sw60" 67: fffc43 10:00:00:60:69:10:60:1f 192.168.64.187 0.0.0.0 "sw187" The Fabric has 4 switches 2-158 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 193
FC Router IP Addr Name 1: fffc01 fcr_sprint_01 10.33.59.224 160: fffca0 fcr_fd_160 0.0.0.0 10.33.59.25 fcr_meteor2 190: fffcbe fcr_mojo_6 10.33.59.32 The Fabric has 3 switches See Also switchShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-159 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 194
ACC F2,P1 F2,P2 21 0x279 11957:87 ELP ACC Receive F2,P2 F2,P2 21 0x277 switch:admin> fabstateclear switch:admin> fabstateshow Time Stamp Input and *Action S, P Sn,Pn Port Xid See Also fabStateShow, fabricLog 2-160 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 195
0x277 switch:admin> fabstateresize 64 Warning: This command will clear the logs. Are your sure you want to do the resize [y/n]? y switch:admin> fabstateshow Time Stamp Input and *Action S, P Sn,Pn Port Xid See Also fabricLog, fabStateClear, fabStateShow Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 196
Examples none To display the fabric state information: switch:admin> fabstateshow Time Stamp Input and *Action S, P Sn,Pn Port Xid 11955:655 SCN Switch Online F2,NA F2,NA NA NA 11955:657 , fabricLog 2-162 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 197
the statistics for the fabric. The information displays as follows: • Number of times a switch domain ID has been forcibly changed • Number of E_Port offline transitions • Number of that may be in place. Operands none Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-163 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 198
readability. fabStatsShow Examples To display the fabric statistics: switch:admin> fabstatsshow Description Count Domain ID forcibly changed: : 0 Duplicate WWN: 0 Eport Isolated: 0 See Also fabRetryShow 2-164 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 199
Fabric Switch State Structure Information State: D0 Stage: warm done Rdi Receive Timer: 0x10069400, IDLE STATE Unconfirmed Sw Timer: 0x10069508, IDLE STATE NTP Timer: 0x100695b8, IDLE STATE ME Timer: 0x10069610, IDLE STATE Principal Domain: 2 Upstream Port: 64 Principal - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 200
2 Note: Enter commands in lowercase only; mixed case is for readability. fabSwitchShow See Also supportShow 2-166 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 201
that may be in place. Operands Examples This command has the following operand: unit Specifies the fan unit number to disable. To disable a fan unit: switch:admin> fandisable 1 Fan unit 1 has been disabled See Also fanEnable, fanShow Fabric OS Command Reference - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 202
Use this command to set a previously disabled fan unit back to the default RPM speed. Note This command is not available on nonbladed systems except for fan unit number to enable. To enable a fan unit: switch:admin> fanenable 1 Fan unit 1 has been enabled See Also fanDisable, fanShow - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 203
speed is displayed. Note The output from this command varies depending on switch type and number of fans present. Note The execution of this in place. Operands Examples none To display information on the fans in the system: switch:admin> fanshow Fan #1 is OK, speed is 2721 RPM Fan #2 is OK - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 204
to Admin Domain restrictions that may be in place. Operands Examples none To reboot the Control Processor, without executing POST on startup: switch:admin> fastboot See Also diagDisablePost, diagEnablePost, reboot 2-170 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 205
to "Blue_fazone": switch:admin> fazoneadd "Blue_fazone", "H{5,6}" To add another target member to "Blue_fazone": switch:admin> fazoneadd "Blue_fazone", "10:49:00:00:00:20:3f:2e" See Also fazoneCreate, fazoneDelete, fazoneRemove, fazoneShow Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 206
contain devices connected to switch 2, ports 12 and 14, and the device with a switch reboots, it must be saved to nonvolatile memory using the cfgSave command. Note When security is enabled, this command can be issued only from the primary FCS switch. 2-172 Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 207
, "10:49:00:00:00:20:3f:2e"). • Fabric Assist zone alias names. • Exactly one Fabric Assist host member (for example, "H{1,2}"). This operand is required. To create three Fabric Assist zones using a mixture of port numbers and Fabric Assist zone aliases: switch:admin> fazoneCreate "Red_fazone - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 208
cfgEnable command. For the change to be preserved across switch reboots, it must be saved to nonvolatile memory using can be issued only from the primary FCS switch. Operands Examples This command has the following To delete a Fabric Assist zone: switch:admin> fazonedelete "Blue_fazone" See Also - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 209
, "1,2"). View the area numbers for ports using the switchShow command. • WWNs (for example, "10:49:00:00:00:20:3f:2e"). Refer to fazoneCreate for more switch:admin> fazoneremove "Blue_fazone", "array2" See Also fazoneAdd, fazoneCreate, fazoneDelete, fazoneShow Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 210
the value defaults to 0. To display all Fabric Assist zones beginning with the letters A through C: switch:admin> fazoneshow "[A-C]*" fazone: Blue_fazone 1,1; array1; 1,2; array2 See Also fazoneAdd, fazoneCreate, fazoneDelete, fazoneRemove 2-176 Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 211
and LBIST -unit number Specifies the GbE port to test. By default, all GbE ports in the specified slotnumber are used. Valid number values include: 0 GbE port 0 1 GbE port 1 2 All GbE port To run all tests on slot 7 and GbE port 1: switch:admin> fcipchiptest --slot 7 -unit 1 -testtype - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 212
the test might report one or more of the following error messages: • CHIP_TEST_ERR • CHIP_TEST_CHIP_INIT_ERR • CHIP_TEST_IMAGE_VER_ERR • CHIP_TEST_TIMEOUT_ERR • CHIP_TEST_HEARBEAT_ERR • CHIP_TEST_INVALID_RESULT fcipPathTest 2-178 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 213
. Note This command is supported only on SilkWorm FR4-18i blades and SilkWorm 7500 platforms. Operands This command has the following operands: --slot slotnumber Specifies the slot number on which the diagnostic operates. The default is 0 and operates on fixed-port-count products. -unit number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 214
is for readability. fcipPathTest Examples To run the test on slot 2 with PHY loopback sending 10 frames: switch:admin> fcippathtest --slot 2 -path 2 -nframes 10 Running fcippathtest Test Complete: fcippathtest Pass 10 of 2-180 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 215
by query: 1 LUN ID: 0x00 To display the LUN information of a list of port WWNs: switch:admin> fclunquery -w 20:00:00:04:cf:5d:cf:0e Target Index: 1 Target Node WWN: 20:00:00:04:cf:5d:cf:0e Target Port WWN: 21:00:00:04:cf:5d:cf:0e Target Pid: 207ef Number of - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 216
the destination identifier is either source or destination. The echo ELS might not be supported on all devices. In such cases, the response could be either an ELS reject or a request timeout. By default, fcPing sends five ELS Echo requests to each port. Note When a device does not respond to the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 217
port ID, port WWN, or node WWN. To display one device that accepts the request and another device that rejects the request: switch:admin> fcping 10:00:00:00:c9:29:0e:c4 21:00:00:20 = 0/0/0 usec See Also gettimeofday, ping Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-183 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 218
of this command is subject to Admin Domain restrictions that may be in place. Operands Examples none To clear the FCPD debug information log: switch:admin> fcplogclear See Also fcpLogDisable, fcpLogEnable, fcpLogShow 2-184 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 219
of this command is subject to Admin Domain restrictions that may be in place. Operands Examples none To disable the FCPD debug information log: switch:admin> fcplogdisable See Also fcpLogClear, fcpLogEnable, fcpLogShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-185 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 220
information logged for FCPD. Debug information logging is enabled by default. Note The execution of this command is subject to Admin Domain information log: switch:admin> fcplogenable See Also fcpLogClear, fcpLogDisable, fcpLogShow 2-186 Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 221
switch:admin> fcplogshow Time Stamp Event Port :0 :0 :0 :0 22:34:14.232 FlshOrProbe 26 1 459 80 :0 :0 :0 :0 22:34:14.232 PrbMsg 26 1 494 0 :0 :0 14.236 ElsRsp 26 1 1606 11ace :2000000 :20 :0 :980000 22:34:14.238 SndPRLI 26 1 Manual Publication Number: 53-1000240-01 2-187 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 222
systems. Use switchShow to list valid ports. This operand is required. To display the FCP probe information: switch:admin> fcpprobeshow 4/4 port 52 is L-Port and it is online. nodes See Also portLoginShow, portLogShow 2-188 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 223
list valid ports. This operand is required. To display the FCP RLS information: switch:admin> fcprlsshow 2/5 0xda 0xdc link fail 0 0 loss sync 5 3 loss sig 0 0 prtc err 0 0 bad word 525 330 crc err 0 0 See Also portLoginShow, portLogShow Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 224
reached (0x80000000 for a 32-bit register). For supported only on SilkWorm FR4-18i blades and SilkWorm 7500 platforms. Operands This command has the following operands: --slot slotnumber Specifies the slot number on which the diagnostic operates. The default is 0 and operates on fixed-port - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 225
fcrChipTest 2 Examples To run all tests on slot 7 and FC Router FPGA 1: switch:admin> fcrchiptest --slot 7 -unit 1 -testtype 0 Running fcrchiptest Test Complete: fcrchiptest fcrPathTest, miniCycle, portLoopbackTest Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-191 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 226
the fabric attached to the U_Ports-for example, E/F_Ports- of this switch. The backbone fabric ID must be unique across all FC Routerconnected fabric ID: (1-128)[100] See Also fcrDisable, fcrEnable, switchDisable, switchEnable 2-192 Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 227
switch. This command can be run while the switch state is "online". Instead of disabling the switch, issue this command to disable the FC Routing service OS switch is in Routing service is service Operands none Examples To disable the FC Routing service: fcr:admin> fcrdisable FC Routing service - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 228
fcrenable Description Use this command to enable the Fibre Channel (FC) Routing service on a switch. In Fabric OS v5.1 the FC Routing service is enabled by default. In Fabric OS v5.2 the FC Routing service is disabled by default, and this commmand must be executed to enable it. Use fosConfig - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 229
about these EX_Ports. This information includes: EX_Port The port number for the EX_Port. FID The fabric ID of the EX_Port. Neighbor Switch Info (WWN, enet IP, name) The WWN, Ethernet IP address, and switch name of the switch attached to the EX_Port. Operands none Examples To display - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 230
ASIC by sending frames from the FC Router FPGA port N's transmitter, and looping the frames back into the same port N's receiver. The loopback is accomplished at the , 0x78, 0x78, 0x78, ... 0xbc, 0xbc, 0x23, 0x47, ... 2-196 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 231
send. The test progresses until the specified number of frames are transmitted on each port. The default value is 10. To test slot 2 with FC Router FPGA Serdes loopback sending 10 frames: switch:admin> fcrpathtest --slot 2 -path 2 -nmegs 10 Running fcrpathtest Test Complete: fcrpathtest Pass 10 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 232
same backbone fabric as this FC Router. The default output displays only physical device information relevant to this and -w operands allow searching for physical devices based on fabric ID or port World Wide Name. "No device found" is displayed if there is Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 233
:0e 0100ef 3 50:05:07:65:05:84:0b:83 0100e8 Total devices displayed: 3 See Also fcrFabricShow, fcrProxyDevShow, fcrRouteShow, lsanZoneShow, switchShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-199 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 234
The imported fabric ID of the proxy device. devWWN The port World Wide Name of the device. Slot The slot used the port_ID [01H through 7FH]) for the edge fabric specified (1 through 128). "WWN does not exist in any proxy device slot" is displayed Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 235
XX:XX) from its slot for the edge fabric specified by importedFID (1 through 128). "WWN does not exist in any proxy device slot." is displayed if the 07:65:05:84:0a:7b 22:00:00:20:37:c3:11:71 22:00:00:20:37:c3:1a:8a 10:00:00:00:c9 OS Command Reference Manual Publication Number: 53-1000240-01 2-201 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 236
by FC Routers on the same backbone fabric as this FC Router. The default output displays only proxy device information relevant to this FC Router. Relevant proxy wwn Displays proxy devices with the specified port WWN. 2-202 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 237
2 Examples To display the proxy devices relevant to this FC Router: switch:admin> fcrproxydevshow Proxy WWN Proxy Device Physical State Created PID Exists PID in fcrRouteShow, lsanZoneShow, switchShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-203 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 238
switch could still be accessible through other switches. Across a switch reboot, the allocation starts from the next usable WWN from the pool and not from the beginning. Phantom Port physical port for routing decision purposes. Operands none 2-204 Fabric OS Command Reference Manual Publication - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 239
10000 20 Phantom Node WWN: Phantom Port WWN: WWN Pool Size Allocated 8192 5413 32768 16121 Port Limits: Max proxy devices: 2000 Max | 6 34 13 | 6 34 14 | 6 34 15 | 6 34 16 | 8 34 17 | 8 34 18 | 8 34 19 | 8 34 20 | 8 34 21 | 8 34 22 | 8 34 23 | 8 34 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 240
: fcr:admin> fcrrouterportcost Port Cost 7/3 1000 7/4 1000 7/9 1000 7/10 1000 7/16 10000 10/0 10000 To display the cost of one EX_Port: fcr:admin> switch:admin> fcrrouterportcost 7/10 Port Cost 7/10 1000 2-206 Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 241
: Enter commands in lowercase only; mixed case is for readability. fcrRouterPortCost 2 To set the cost of an EX_Port: fcr:admin> switch:admin> fcrrouterportcost 7/10 10000 See Also switchShow, fcrRouteShow, portCfgEXPort Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-207 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 242
SAN. There are FC Router ports that reside on the backbone fabric. These ports port IDs relevant to the backbone fabric. Because cascaded backbone/intermediate fabrics are currently not supported Fabric Id PID Switch in the 20:ed 5 640300 1000 10:00:00:60:69:c0:20:ed See Also fcrFabricShow - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 243
active and is persistently saved. The principal switch attempts to provide the translate domain with the 128) of the remote fabric represented by this translate domain. preferredDomainID Specifies the preferred domain ID (1 through 239) of the translate phantom. Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 244
created in fabric 2 that represents remote fabric 3: fcr:admin> fcrxlateconfig -r 2 3 xlate domain deleted See Also portCfgEXPort, portCfgVEXPort, portDisable, portEnable, portShow 2-210 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 245
Supported policies are Switch Connection Control (SCC), Device Connection Control (DCC) and Password (includes account database and password policies To set the FabricWide Consistency Policy to NULL (default), meaning none, specify policy_set as "". Supported policies are SCC and DCC. Examples To - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 246
--localreject "SCC;DCC" Local Switch Configured to reject policies. To set the Fabric-Wide Consistency Policy to "strict" for SCC and "tolerant" for DCC: switch:admin> fddcfg --fabwideset "SCC:S;DCC" See Also distribute 2-212 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 247
3 state: known version: v310 wwn: 10:00:00:60:69:90:03:c7 HBAs: 10:00:00:00:c9:25:9b:96 Ports: 1 10:00:00:00:c9:25:9b:96 Total count of devices on the switch is 1 See Also fdmiShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-213 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 248
: Emulex LightPulse LP9000 1 Gigabit PCI Fibre Channel Adapter Hardware Version: 00000001 Driver Version: SLI-2 SW_DATE:May 3 2002, v5-2.11a2 **CT_TEST 1** Firmware Version: 03814101 OS Name and Version: Window 2000 Max CT Payload Length: 0x00061300 Local Port database contains: 10:00:00:00:c9:25 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 249
that "current" entries are not removed from the RNID database. To clear the RLIR database: switch:user> ficonclear RLIR successfully clear local RLIR Database. To clear RNID database: switch:user> ficonclear RNID successfully clear not current entries from local RNID Database. See Also ficonHelp - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 250
| disable ficoncupset modereg bitname 0 | 1 Description Use this command to set FICON-CUP (Control Unit Port) parameters for a switch. All the parameters described below can be set while the switch is online. Changes to parameters are effective immediately. A reboot is not required for the changes - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 251
Control Unit Port) parameters for a switch. Note switch: switch:user> ficoncupshow modereg POSC UAM ASM DCAM ACP HCP 1 0 1 1 1 0 To display ASM bit in the mode register for the switch: switch:user> ficoncupshow modereg ASM ASM --1 See Also ficoncupset Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 252
a list of FICON support commands, with descriptions. Operands none Examples To display a list of FICON commands: switch:admin> ficonhelp ficonclear Sets FICON-CUP parameters for a switch ficoncupshow Displays FICON-CUP parameters for a switch ficonhelp N/A ficonshow Displays contents of - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 253
of the storage port for RNID switch for SwitchRNID is valid. 0x10 Indicates node ID of the channel port is valid. 0x20 Indicates the node ID of the storage port is not current. each incident within the individual switch. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-219 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 254
node type for the switch in three bytes, 0xAABBCC: Byte AA 0x20 FC-SB-2 and updates. Byte BB 0x0a Switch. Byte CC 0x00 Port number. It is dynamically including FCP and updates. 0x80 FC-4 support not specified. 0xa0 Reserved. 0xc0 Reserved. 0xe0 Vendor specific. Fabric OS Command Reference - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 255
CC 0x00 If storage CU port has registered with the switch. 0xID CHIPID if channel port has registered with the switch. 0xPN If switch has registered with the channel, PN represents the FL port number. Part Number Displays the switch chassis part number. PID Displays the 24-bit Fibre Channel - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 256
switch serial number. Switch node WWN Displays the switch node World Wide Name. Switch Port WWN Displays the switch port World Wide Name. Switch WWN Displays the switch the switch on which the command is issued displays. 2-222 Fabric OS Command Reference Manual Publication Number: 53-1000240- - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 257
LIRR database: switch:admin> ficonshow LIRR fabric {Fmt Type PID Listener Port WWN Switch Port WWN Listener Type 0x18 N 502b00 50:05:07:64:01:00:15:8d 20:2b:00:60 } } The Local switch RNID database has 1 entries. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-223 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 258
WWN Registered Node WWN 50:05:07:64:01:40:0f:ca 50:05:07:64:00:c1:69:ca Type Number: 002064 Model Number: 101 Manufacturer: IBM Plant of Manufacture: 02 Sequence Number: 0000000169CA tag: 2e00 Flag 0x50 Node Parameters 0x200105 Switch Port WWN Switch Node WWN 20:2e:00:60:69:80:1e - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 259
port and send the frame in internal loopback mode. The filter test requires two different ports in the same quadrant because the filter logic in the transmitter port Zone A|B match and AL_PA match Discard Note This command is supported only on SilkWorm 3250, 3850, 3900,12000, and 24000 platforms - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 260
the diagnostic operates. The port specified are relative to this slot number. The default is 0 and designed to is larger than the limit. To run a frame filter test: switch:admin> filtertest -txports 3/1-3/3 Running filtertest Test Complete: filtertest Pass Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 261
switches the primary partition (with the old firmware) to the secondary, and the secondary partition (with the new firmware) to the primary. The default partition (with new firmware) to the secondary and commits the new firmware to both partitions version of the firmware: switch:admin> firmwarecommit - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 262
switch are ignored. Save your configuration if you are downgrading to Fabric OS v4.2.2. You might lose some of the enabled features available in the current firmware; for example, Fabric OS v5.x supports a zone DB of 256 Kb but v4.2.2 supports only 128 Kb. 2-228 Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 263
Note: Enter commands in lowercase only; mixed case is for readability. firmwareDownload 2 Note The execution of this command is subject to Admin Domain restrictions that may be in place. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-229 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 264
default, after running this command and after the reboot, the switch file name for the firmware package list, excluding password is required by the FTP server. If no operand is specified, the operation becomes interactive and you are prompted for input. 2-230 Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 265
switch • host cannot be reached by the switch • user does not have permission on host • The pfile does not exist on host • The pfile is not in the right format • Package specified in the pfile does not exist • The FTP server is not running on host • Platform is not supported by the firmware - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 266
[1]: Fri Feb 15 22:17:03 2008 Firmware is being downloaded to the switch. This step may take up to 30 minutes. [2]: Fri Feb 15 22:20:54 2008 Firmware has been downloaded to the secondary partition of the switch. [3]: Fri Feb 15 22:22:19 2008 The firmware commit operation has started. This may take - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 267
active CP. [16]: Mon Dec 19 19:01:39 2005 Slot 5 (CP0, active): Firmwaredownload command has completed successfully. Use firmwareshow to verify the firmware versions. See Also firmwareCommit, firmwareDownload, firmwareRestore, firmwareShow Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 268
that may be in place. Operands Examples none To restore the former active firmware image: switch:admin> firmwarerestore Restore old image to be active ... Restore both primary and See Also firmwareCommit, firmwareDownload 2-234 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 269
Admin Domain restrictions that may be in place. Operands Examples none To display the firmware version of a SilkWorm switch: switch:admin> firmwareshow Primary partition: v5.1.0 Secondary Partition: v5.1.0 To display the firmware version of a SilkWorm director with FR4-18i blades installed - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 270
. Synopsis fporttest [-nframes count][-ports itemlist][-seed payload_pattern][-width pattern_width] [-size pattern_size] Description Use this command to verify the functional operation of the switch by sending ELS Echo frames from the switch F_Port transmitter and receiving ELS Echo ACC from the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 271
(default) 1 BYTE_LFST 2 CHALF_SQ 3 QUAD_NOT 4 CQRT_SQ 5 CRPAT 6 RANDOM All other values are modularized into is omitted, the default value is 512. This operand is optional. To run fportTest on a switch: switch:admin> fporttest -ports 1/0-1/15 Running fPortTest Manual Publication - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 272
STATS_FTX TIMEOUT XMIT Refer to the Fabric OS Message Reference for more information. See Also crossPortTest, itemList, loopPortTest, portTest, spinFab 2-238 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 273
on the switch. Valid values for feature are: • fcr The FC Routing service will be enabled on this switch. The FC Routing service is by default disabled on a new switch with Fabric command was issued. Take these ports offline Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-239 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 274
stating "Command not supported on this platform" is displayed. Examples To display the status of the features: switch:admin> fosconfig --show FC Routing service: iSCSI service: iSNS Client service: enabled enabled disabled To disable the FC Routing service: switch:admin> fosconfig --disable - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 275
guide supported value, specifying the replacement of the WWN card. To replace the World Wide Name card: switch Switch WWN Card Removal and Replacement document. Do you wish to continue [y/n]? y Backing up WWN card data, please wait about 25 seconds for further instruction the instructions to 20 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 276
correspond to the default areas of the ports. Bit 0 refers to default area of the switch, bit 1 refers to default area 1, and so forth. trunk_ports Bit map of all the trunk slave ports. f_ports Bit map be in place. 2-242 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 277
fspfShow 2 Operands Examples none To display FSPF protocol information: switch:admin> fspfshow version = 2 domainID = 131 switchOnline = TRUE fabP: event_sch = 0x0 See Also bcastShow, topologyShow, uRouteShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-243 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 278
is specified, the default value is 0 (alarms deactivated). This operand is optional. To enable alarms in Fabric Watch: switch:admin> fwalarmsfilterset Committing configuration...done. FW: Alarms are disabled switch:admin> fwalarmsfilterset - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 279
. Operands Examples none To display the status of alarm filtering in Fabric Watch: switch:user> fwalarmsfiltershow FW: Alarms are enabled switch:user> fwalarmsfiltershow FW: Alarms are disabled See Also fwAlarmsFilterSet Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-245 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 280
is subject to Admin Domain restrictions that may be in place. Operands Examples none To initialize all classes under Fabric Watch: switch:admin> fwclassinit fwClassInit: Fabric Watch is updating... fwClassInit: Fabric Watch has been updated. See Also fwConfigReload, fwConfigure, fwShow 2-246 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 281
to Admin Domain restrictions that may be in place. Operands Examples none To reload the saved Fabric Watch configuration: switch:admin> fwconfigreload fwConfigReload: Fabric Watch configuration reloaded See Also configDownload, configUpload, fwClassInit, fwConfigure, fwShow Fabric OS Command - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 282
enable all thresholds associated with a given port. Note This command requires a Fabric Watch license. Not all platforms support fans or power supplies. If you attempt E_Port Same as Port class F/FL_Port (Optical) Same as Port class 2-248 Fabric OS Command Reference Manual Publication Number: - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 283
This command has the following optional operands: --enable --port portNumber Enables all thresholds associated with a certain port. --disable --port portNumber Disables all thresholds associated with a certain port. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-249 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 284
only; mixed case is for readability. fwConfigure Examples To configure thresholds: switch:admin> fwconfigure 1 : Environment class 2 : SFP class 3 : Port class 4 : Fabric class 5 : E-Port class 6 : F/FL Port (Optical) class 7 : Alpa performance Monitor class 8 : EE performance Monitor class - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 285
displays. To change FRU state alert configuration: switch:admin> fwfrucfg The current FRU configuration: Alarm -1, Inserted-2, On-4, Off-8, Faulty-16 Configurable Alarm Actions are: Errlog-1, E-mail-16 Slot Alarm State: (0..31) OS Command Reference Manual Publication Number: 53-1000240-01 2-251 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 286
level to default Show thresholds monitored or port persistence time Show sensor readings Set switch status policy parameters Show switch status policy parameters Show overall switch status Show switch temp readings See Also none 2-252 Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 287
F/FL Port (Optical) class 7 : Alpa Performance Monitor class 8 : End-to-End Performance Monitor class 9 : Filter Performance Monitor class 10 : Security class 11 : Resource class 12 : FRU Class 13 : Quit Select an item => : (0..13) [11] 1 (continued on next page) Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 288
Mail Config Menu 1 : Environment class 2 : SFP class 3 : Port class 4 : Fabric class 5 : E-Port class 6 : F/FL Port (Optical) class 7 : Alpa Performance Monitor class 8 : End-to , fwConfigure, ipAddrSet, ipAddrShow 2-254 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 289
is healthy Marginal One or more contributors are in this status Faulty Faulty hardware Offline Port has no connectivity or is disabled If the overall status is not healthy, the restrictions that may be in place. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-255 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 290
ports f Report based on all faulty ports o Report based on all offline ports If no option is specified, all ports are displayed. To retrieve a port detail report: switch:user> fwportdetailshow --s h Port Detail Report Switch Name: switch Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 291
on an eight port switch: switch:user> fwsamshow Total Total Down Total Port# Type Up Time Down Time Occurrence Offline Time (Percent) (Percent) (Times) (Percent) 0 U_PORT 0 0 0 100 1 U_PORT 0 0 0 100 2 U_PORT 0 0 0 100 3 E_PORT 21 0 0 78 4 E_PORT 20 0 0 80 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 292
is the time period in which a port must be persistently in a state before being actually being recognized as such. To set message levels and port persistence time: switch:user> fwset --port --persistence 18 See Also fwShow 2-258 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 293
this command is subject to Admin Domain restrictions that may be in place. Operands Examples none To set alarm levels to custom values: switch:admin> fwsettocustom Committing configuration...done. See Also fwSetToDefault Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-259 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 294
levels to the default values. Synopsis fwsettodefault Description Use this command to return boundary and alarm levels to defaults for all classes Operands Examples none To return alarm levels to default values: switch:admin> fwsettodefault Committing configuration...done. See Also fwSetToCustom - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 295
The operands are as follows: --port --persistence Displays the time that a port must be persistently in a state before being marked as such. --disable --port Displays the ports that have all associated thresholds disabled. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 296
To display thresholds and port persistence time: switch:user> fwshow 1 : Show class thresholds 2 : Detail threshold information 3 : Show console message level 4 : Show port persistence time 5 : (continued on next page) 2-262 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 297
:02 on 12/09/2011 * Event 5 occurred 1 time, last at 16:30:23 on 12/09/2011 Callbacks: No callbacks are registered. switch:user> fwshow --port --persistence FW: current port persistence time = 18s switch:user> fwShow --disable --port Port Threshold Status 1 disabled See Also fwClassInit - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 298
commands to be edited. The h command displays the 20 most recent commands typed into the shell; the oldest mode and then use vi commands. The ESC key switches the shell to edit mode. The ENTER key gives none Examples To display previous shell commands: switch:admin> h 1 version 2 switchshow 3 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 299
The execution of this command is subject to Admin Domain restrictions that may be in place. Operands Examples none To disable the High Availability feature: switch:admin> hadisable HA is disabled See Also haEnable Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-265 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 300
feature in the switch. Synopsis hadump Description the High Availability feature in the switch. This command displays the following information health diagnostic has discovered a problem with the blade. The Fibre Channel addresses configured for the switch. • Additional internal HA state - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 301
6, CP1): Active, Cold Recovered Remote CP (Slot 5, CP0): Non-Redundant ipaddrshow: SWITCH Ethernet IP Address: 10.33.54.251 Ethernet Subnetmask: 255.255.240.0 Fibre Channel output truncated> --- See Also haFailover, haShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-267 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 302
the High Availability feature in the switch. Synopsis haenable Description Use this command to enable the High Availability feature in the switch. If the HA feature is High Availability feature in the switch: switch:admin> haenable HA is enabled See Also haDisable 2-268 Fabric OS Command - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 303
Availability (HA) synchronization is enabled and the CPs are in sync, the port traffic light does not flash during the failover, even while traffic is continuing will cause the active CP to reset. This will cause disruption to devices attached to all the switches supported by the CP and will require - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 304
CP is running, but the background health diagnostic has discovered a problem with the blade. The logs should be checked to determine the CP reboots, and the failover is disruptive. Note This command might not be supported on non-bladed systems. Note The execution of this command is subject to - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 305
Non-Redundant switch:admin> hashow Local CP (Slot 6, CP1): Active, Warm Recovered Remote CP (Slot 5, CP0): Standby, Failed Backplane PCI fail, severity: CRITICAL HA enabled, Heartbeat Up, HA State not in sync See Also haDisable, haEnable, haFailover Fabric OS Command Reference Manual Publication - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 306
. Note The execution of this command is subject to Admin Domain restrictions that may be in place. Examples To enable the HA state synchronization: switch:admin> hasyncstart HA State synchronization has started See Also haFailover, haShow, haSyncStop 2-272 Fabric OS Command Reference - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 307
of this command is subject to Admin Domain restrictions that may be in place. Operands Examples none To disable the HA state synchronizing process: switch:admin> hasyncstop See Also haFailover, haShow, haSyncStart Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-273 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 308
this can vary, according to: • Login user role • License key • Switch model To access help information for a specific command, enter the command name as optional. Examples To display help information for the help command: switch:admin> help help See Also diagHelp, fwHelp, licenseHelp, perfHelp, - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 309
following data sets: Object type CHASSIS, FAN, POWER SUPPLY, SW BLADE (port blade), CP BLADE (control processor), WWN (World Wide Name card), Operands Examples none To display the late FRU insertion or removal event: switch:admin> historylastshow POWER SUPPLY Unit 2 Inserted at Tue Aug 14 15: - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 310
operands: rot Rotating mode. fi Log is filled once, then new entries are discarded. Examples To change the history mode to first-in from rotating: switch:admin> historymode History Mode is: Rotating. See Also historyLastShow, historyShow 2-276 Fabric OS Command Reference - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 311
contains the following: Object type CHASSIS, FAN, POWER SUPPLY, SW BLADE (port blade), CP BLADE (control processor), WWN (WWN card), or UNKNOWN Object xxxxxxxxxxxx or Unknown SilkWorm directors support 100 history log entries; all other platforms, which contain FRUs, support 28 entries. Note The - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 312
history log of FRUs and removal events: switch:admin> historyshow FAN Unit 3 Removed at Tue Aug 14 10:05:37 1970 Factory Part Number: 20-123456-12 Factory Serial Number: 1013456800 POWER See Also historyLastShow 2-278 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 313
Description Use this command to display the version of the Java plug-in supported by Web Tools. This command also displays the URL from which the Operands Examples none To display the Java plug-in version: switch:admin> httpcfgshow Current HTTP configuration javaplugin.version = 1,3,1 javaplugin. - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 314
priority computation ADDR Memory address of the process SZ The total size of the process in virtual memory, in pages 2-280 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 315
has the following operand: processID Specifies the process name or process ID for the process to display. To display information about process ID 433: switch:admin> i 433 F S UID PID PPID C PRI NI ADDR SZ WCHAN TTY TIME CMD 000 S 0 433 1 0 69 0 - 1283 5c64 ? 00:00:02 fabricd See Also - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 316
is not prompted when the command is used through the serial console port. For dual-CP systems, the ifModeSet command affects the CP that PHY transceiver. This command is not supported on SilkWorm 3016 switches. The internal Ethernet in the IBM Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 317
port, follow this scenario for the ifModeSet command: switch:admin> ifmodeset eth0 Exercise care when using this command. Forcing the link to an operating mode not supported configuration...done. See Also ifModeShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-283 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 318
0 is the physical unit. To display the link operating mode for the "eth0" Ethernet interface: switch:admin> ifmodeshow eth0 Link mode: negotiated 100baseTx-HD, link ok MAC Address: 00:60:69:D0:24:40 See Also ifModeSet 2-284 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 319
masterPort Port number of the trunk master port, if present, of the trunk group of which this port is a part. defaultCost Default cost switch. idbNo IDB number. Should be equal to port_number. remPort Port number on the remote switch connected to this port. Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 320
milliseconds. When this timeout expires, a Hello frame is sent to the neighbor switch through this port. Retransmission timeout value, in milliseconds. It is used to transmit topology information to the neighbor switch. If no acknowledgement is received within this value, the frame is retransmitted - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 321
interface information: switch:user> interfaceshow 1/4 idbP = 0x1008b3d0 Interface 4 data structure: nghbP ifNo masterPort defaultCost cost delay lastScn lastScnTime upCount lastUpTime downCount lastDownTime downReason iState = 0x1008c668 = 4 = 4 (self) = 500 = 500 = 1 = 16 = Apr 02 20:01:44 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 322
nCmdAcc = 7 nInvCmd = 0 nHloIn = 2 nInvHlo = 0 nLsuIn = 2 nLsaIn = 3 attHloOut = 2 nHloOut = 2 attLsuOut = 3 nLsuOut = 3 attLsaOut = 2 nLsaOut = 2 See Also nbrStateShow, portShow, switchShow 2-288 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 323
disabled, configuration parameters are returned to their default states and can be changed using configure. Note Only Port World Wide Name zoning is supported in interoperability mode. Note FC Routing services are not available in interop mode. Switches connected to edge fabrics are not available - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 324
(yes, y, no, n): [no] y Interopmode is disabled. Note: You MUST reboot this switch for the new change to take effect. To see connections on a switch that is operating in interop mode (ports 8/0, 8/1 show the connections to 2-290 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 325
readability. interopMode 2 the Brocade fabric; ports 8/2, 8/3 show the 20 04d400 -- -- Offline Disabled (Persistent) [output truncated] 223 8 31 04df00 -- -- Offline Disabled (Persistent) 8 ge0 id 1G Online FCIP 8 ge1 id 1G Online FCIP See Also configure Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 326
Use this command to turn off the IOD option. The IOD option is turned off by default; however, if the IOD option was turned on using iodSet, this command can be none To turn off the IOD option: switch:admin> iodreset switch:admin> iodshow IOD is not set See Also iodSet, iodShow 2-292 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 327
are not delivered out-of-order, even during fabric topology changes. The default behavior is for the IOD option to be off. This command should be IOD option: switch:admin> iodset switch:admin> iodshow IOD is set See Also iodReset, iodShow Fabric OS Command Reference Manual Publication Number: - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 328
Use this command to display whether the IOD option is enabled or disabled. Operands none Examples To display the current setting of the IOD option: switch:admin> iodshow IOD is not set See Also iodReset, iodSet 2-294 Fabric OS Command Reference - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 329
switch or CP. The command's usage varies depending on whether it is being used on a chassis-based system or nonchassis-based switch set the switch IP address use -sw. When setting the switch, the command switch and CP numbers depend nonchassis-based switch, the of logical switch 0. 1 Sets - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 330
case is for readability. ipAddrSet Examples To set the IP address details for switch number 1 on a chassis-based system: switch:admin> ipaddrset -sw 1 Ethernet IP Address [192.168.166.148]: .1]: DHCP [Off]: on ipAddrShow 2-296 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 331
the IP address for logical switch 0: switch:admin> ipaddrshow -sw 0 Ethernet IP Address: 192.168.166.147 Ethernet Subnetmask: 255.255.255.0 Fibre Channel IP Address: 0.0.0.0 Fibre Channel Subnetmask: 0.0.0.0 See Also ipAddrSet Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 332
--clear initiator [-h ] iscsicfg --show initiator [-i initiator_name] [-h ] iscsicfg --abort transaction -x transaction_id [-h ] iscsicfg --show transaction [-h ] iscsicfg --clear all [-h ] iscsicfg --commit all [-f ] [-h ] 2-298 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 333
the target prefix followed by the port WWN. • --easycreate tgt -s [-h ] Shows the Node and Port WWNs which will be used for any easycrate operation from this switch. • --create tgt -t • --delete tgt -t target_name [-h ] Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-299 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 334
[-h ] Adds the LUN map to target_name. port_wwn specifies the port WWN of the physical FC target whose LUNs are to be mapped IQN format is supported. Multiple entities may be specified as a commaseparated list. The IQN may be a maximum of 64 characters. • Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 335
auth -u user1 -s abcdefg123 The operation completed successfully. To modify a CHAP entry associated with an existing user: switch:admin> iscsicfg --modify auth -u user1 -s newsecret The operation completed successfully. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-301 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 336
Status 1 21:00:00:20:37:df:8e:e3 iqn.2002 12.com.brocade:21:00:00:20:37:df:8e:e3 Operation Succeeded 2 21:00:00:20:37:df:83:fc iqn.2002-12.com.brocade:21:00:00:20:37:df:83:fc Operation Succeeded 2-302 Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 337
switch:admin> iscsicfg --add lun -t iqn.2005-10.com.brocade.tgt1 -w 22:00:00:04:cf:20:5d:33 -l 0:0 The operation completed successfully. switch:admin> iscsicfg --add lun -t iqn.2005-12.com.brocade specified name and members: switch:admin> iscsicfg --create dd the DD database: switch:admin> iscsicfg - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 338
> iscsicfg --show fabric Switch ID Switch WWN * 1 10:00:00:60:69:e4:20:1e Switch State iSNSC -- Disabled Aggregated iSCSI database state for fabric: In Sync Displays switches that are capable of propagating iSCSI data base. 2-304 Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 339
found: 1 Name iqn.1991-05.com.brocade:initiator1 IP Address 172.16.14.101 switch:admin> iscsicfg --show initiator -i iqn.1991-05.com.brocade:initiator1 Initiator details are: Name IP Address iqn.1991-05.com.brocade:isi154116.englab.brocade.com 172.16.14.101 No. of targets currently accessible - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 340
. By default all the GE ports in the specified slot slotnumber will be used. This number will be between 0 and 7. 8 will mean all ports. Examples To run iscsichiptest: switch:admin> iscsichiptest --slot 7 -unit 1 -testtype 0 Running iscsichiptest Test Complete: iscsichiptest Pass 1 of 1 Duration - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 341
descriptions. Operands none Examples To display the list of iSCSI support commands: switch:admin> iscsihelp fclunquery Display a list of LUNs of FC target(s). fosconfig Enable/disable FabOS services iscsicfg Manage/display all iscsi configuration including authentication/virtual targets - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 342
to send. The test will progress until the specified number of frames has been transmitted on each port. The default value is 100. Examples To run iscsipathtest: switch:admin> iscsipathtest --slot 2 -path 2 -nframes 10 Running iscsipathtest Test Complete: iscsipathtest Pass 10 of 10 Duration 0 hr - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 343
, 2048, 4096, 8192, 16384, and 32768. --clearstats Clears port-level iSCSI statistics on the specified port. --default Resets the port to the default values. See the "Description" section for the list of default values. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-309 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 344
. NOTE: This parameter only supports FC4-16IP blades in SilkWorm 48000 directors. • geport Specifies the port number of a GbE port to be configured in the specified slot. Use -h on any option to display the help text for it. To modify the port parameters: switch:admin> iscsiportcfg --modify 7/ge2 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 345
port information in verbose mode: switch:admin> iscsiportcfg --show 7/ge0 The configured port parameters for slot 7 and port Set: iSCSI Clear ACA: iSCSI Clear Task Set: iSCSI LUN Reset: iSCSI Target Reset: iSCSI Task Reassign: Non FCP in PDU: Non FCP Manual Publication Number: 53-1000240-01 2-311 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 346
. • -i initiator_iqn Selects only sessions that match the given initiator IQN. • -t target_iqn Selects only sessions that match the given target IQN. 2-312 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 347
brocade:2f:df:00:06:2b:0d:10:b9 Session type Init. Session ID Tgt. Session ID Initiator IP Num. Conns . Normal 0x400001370000 1025 30.50.1.115 1 TCP Connection Details Index TCP Port Leading Connection Switch Port outstanding R2T 1 16 Default time to retain 20s 60s Default time to - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 348
Abort Task: iSCSI Abort Task Set: iSCSI Clear ACA: iSCSI Clear Task Set: iSCSI LUN Reset: iSCSI Target Reset: iSCSI Task Reassign: Non FCP in PDU: Non FCP in Octet: Non FCP out PDU: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2-314 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 349
target names. The default prefix is iqn.2002-12.com.brocade. Note The brocade To change the target name prefix: switch:admin> iscsitargetname --modify -u iqn.2002-10.com.brocade The operation completed successfully See Also fosConfig, iscsiCfg, iscsiPortCfg Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 350
of the ISL of each port on this switch. The node WWN, domain ID, and switch name to which the ISL 05:1e:01:0b:4a 6:162->160 10:00:00:60:69:e2:09:fa 7:208-> 16 10:00:00:05:1e:37:02:73 3 Termonator8 4 Dazzler_1 15 Stealth_05 5 fcr_meteor2 39 sprint170 Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 351
the port number of a GbE port in an iSCSI blade. NOTE: This parameter only supports FC4- port To display the current configuration of the iSNS client daemon switch:admin> isnsccfg --show iSNS client is peering with iSNS server 192.168.131.124 on slot 7, port ge0 Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 352
Enter commands in lowercase only; mixed case is for readability. isnscCfg To trigger a re-registration of iSNS ojects: switch:admin> isnsccfg --reregister Initiated re-register of iSNS objects with iSNS server See Also none 2-318 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 353
For instance, "0, 16, 32" and "1/0, 2/0, 3/0" specify the same ports on a 16-port/blade system. On that same system, "1/0, 16, 32" is not a valid list: even though it is legal syntax, the ports do not exist. • If no slot number is specified, all lists except user port lists will use the default slot - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 354
ports, internal and external ports UPORTS Switch User ports, ports with external connections QUADS Blade Quadrants, group of (normally four) ports CHIPS Blade Chips, ASICs within a blade MINIS Blade Mini-switches 2-320 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 355
all the current telnet and serial port login sessions. It lists information such open telnet connection: switch:admin> killtelnet Collecting login " since " 6:29pm" and has been inactive for "16.00s ", the current command executed being: "-rbash ". Manual Publication Number: 53-1000240-01 2-321 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 356
2 Note: Enter commands in lowercase only; mixed case is for readability. killTelnet See Also none 2-322 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 357
. Some features of the switch and the fabric to which it is connected are optional, licensed products. Without a license installed for such products, their services are not available. A license key is a string of approximately 16 upper- and lowercase letters and numbers. Case is significant. The - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 358
licenseAdd licenseIdShow licenseRemove licenseShow Add a license to this switch Show system license ID Remove a license from this switch Show current licenses See Also licenseAdd, licenseIdShow, licenseRemove, licenseShow 2-324 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 359
switch and the fabric are optional, licensed products. Without a license installed for such products, the services provided by these features are not available. For dual-domain systems, a single license enables both logical switches display the license ID: switch:admin> licenseidshow a4:f8: - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 360
to remove an existing license key from a switch. The existing license key must be entered exactly product uninstalled. After removing a license key, the switch must be rebooted. With no license key, licenseShow a license key from the switch: switch:admin> licenseremove "bQebzbRdScRfc0iK" removing - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 361
licensed products enabled by these keys. The message "No license installed on this switch" is displayed when no licenses are installed. Note The execution of this command is To display the installed license keys on a switch: switch:admin> licenseshow bQebzbRdScRfc0iK: Web license Zoning license - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 362
500 This command can be used to set a non-default, "static" cost for any port except EX/VEX ports. (Use fcrRouterPortCost to configure EX/VEX ports). When executed without arguments, this command displays the current cost of each port on the switch, even those are not ISL's. Active ISLs have an - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 363
connected to the specified port number. If cost is 0, this port will then revert to its default link cost. This operand is optional. If omitted, this command displays the cost of the specified port. If no operands are specified, the current link costs for all ports on the switch. To display the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 364
you to access commands that you cannot access at your current user level. Operands none Examples To log in as admin from the login user: switch:user> login login: admin Password:xxxxxx See Also logout 2-330 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 365
command is accepted as a synonym for logout, as is Ctrl-D at the beginning of a line. Operands none Examples To log out from an rlogin session: switch:admin> logout See Also login Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-331 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 366
, meaning that a short wavelength SFPed (switch) port is connected to another short wavelength SFPed (device) port through a short wavelength cable; and a long wavelength port is connected to a long wavelength port; and a copper port is connected to a copper port. Only one frame is transmitted and - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 367
Specify the width of the test pattern. Valid values include: 1 byte (default) 2 word 4 quad This operand is optional. To perform a loopback port test: switch:admin> loopporttest -ports 1/0-1/15 Running Loop Port Test ....... Test Complete: "loopporttest" Pass 10 of 10 Duration 0 hr, 0 min - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 368
lsanZoneShow Displays logical SAN zone information. is provided for each LSAN zone. The default output displays only WWNs of the zone members zone members or devices. The default output displays the WWN of the wwn Displays LSAN zones containing the specified port WWN. The WWN format is xx:xx - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 369
lsanZoneShow 2 Examples To display the LSAN zones: switch:admin> lsanzoneshow Fabric ID: 4 Zone Name: 20:37:18:22:55 50:05:07:65:05:84:0b:83 50:05:07:65:05:84:09:0e switch# See Also fcrFabricShow, fcrPhyDevShow, fcrProxyDevShow, fcrRouteShow, switchShow Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 370
• The link state record (LSR), which is allocated when a switch is connected to the fabric. The LSR describes the links between connected fields described in the table display. Table 2-16 lsDbShow Display Fields Field Description Domain Domain number Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 371
2-16 Field options lsId advertiser incarn length chksum linkCnt flags LinkId out port rem port switch on the other side of the link. Port number on the local switch. Port number of the port on the other side of the link. Cost of this link. The default Manual Publication Number: 53-1000240-01 2-337 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 372
2, out port = 16, rem port = LinkId = 2, out port = 17, rem port = LinkId = 2, out port = 18, rem port = LinkId = 2, out port = 19, rem port = LinkId = 2, out port = 24, rem port = LinkId = 2, out port = 25, rem port = LinkId = 2, out port = 26, rem port = LinkId = 2, out port = 27, rem port - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 373
Mem: 129740800 112562176 Swap: 0 0 switch:admin> memshow -m total used Mem: 123 107 Swap: 0 0 free 17178624 0 free 16 0 shared 0 buffers cached 139264 30396416 shared 0 buffers 0 cached 28 See Also saveCore Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 374
hardware so that frames received by port M are retransmitted by way of port N. Likewise, frames received by port N are retransmitted by way of port M. Each port M sends two frames to its partner, port N. This test is run as a series of eight path tests. Each port on the ASIC pair is exchanging - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 375
selected ports. • All ports are and routes are reset for the next switch are faulty. The following operands are optional: --slot slotnumber Specifies the slot number on which the diagnostic operate. The ports specified are relative to this slot number. The default each port. The default value - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 376
not specified, only paths between selected ports are tested. ASIC-pair 0: -ports 0-15 ASIC-pair 1: -ports 16-31 ASIC-pair 2: -ports 32-47 ASIC-pair 3: -ports 48-63 To run a functional test on slot 1 using external (SERDES) loopback: switch:admin> minicycle --slot 1 -lb_mode 2 Running minicycle - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 377
2 To run a functional test on ports 0, 1, 2, and 8 using port loopback: switch:admin> minicycle -ports 0,1,2,8 -lb_mode 1 Back Plane Loop Back mode is ON. Running mini Cycle One moment please ... Path 0 TIMEOUT XMIT Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2- - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 378
to the Fabric OS Message Reference for more information. backport, camTest, centralMemoryTest, cmemRetentionTest, cmiTest, crossPortTest, itemList, portLoopbackTest, portRegTest, spinSilk, sramRetentionTest 2-344 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 379
to operate. The default is 0 and designed to operate on fixed-port-count products. To display all index 1 ASIC pair properties: switch:user> minispropshow 1 -all slot: 1, miniS: 0 [2/16] (be,5) (be,4) (be,3) (be,2) (be,1) (be,0) (bi,55) (bi,54) (bi,25) (bi,24) (bi,41) (bi - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 380
the supported MS capabilities for each switch in the fabric: Switch WWN 10:00:00:60:69:20:15:71 10:00:00:60:69:00:30:05 Capability Name 0x0000008f "switch1"* 0x0000008f "switch2" Capability Bit Definitions: Bit 0: Basic Config Service Supported. Bit 1: Platform Management Service Supported. Bit - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 381
SAN management application to retrieve and administer the fabric and interconnect elements, such as switches. This application is located at the Fibre Channel well-known address, 0xFFFFFA. If the MS ACL is empty (default based on its port/node WWN • 3 Delete member based on its port/node WWN If - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 382
Examples To display the MS ACL: switch:admin> msconfigure 0 Done 1 Display the access list 2 Add member based on its Port/Node WWN 3 Delete member based on its Port/Node WWN select : (0..3) [1] 1 MS Access List consists of (5): { 20:01:00:60:69:00:60:10 20:02:00:60:69:00:60:10 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 383
none To display the MS platform database for a fabric: switch:admin> msplatshow Platform Name: [9] "first obj" Platform Node Names: 1 Associated Node Names: 10:00:00:60:69:20:15:71 Platform Name: [10] "second obj" Platform Type: 10:00:00:60:69:20:15:79 10:00:00:60:69:20:15:75 See Also - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 384
place. Operands Examples none To display the MS platform service database control block: switch:admin> msplatshowdbcb Domain Worldwide Name Retry Count Exchange Status msPlClearDB, msPlMgmtActivate, msPlMgmtDeactivate 2-350 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 385
platform database: switch:admin> msplcleardb MS Platform Service is currently enabled. This will erase MS Platform Service Database in the Service Database!! See Also msCapabilityShow, msConfigure, msPlatShow, msPlatShowDBCB, msPlMgmtActivate, msPlMgmtDeactivate Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 386
in the fabric boot with the MS platform service enabled. By default, the MS platform service is disabled. Before issuing, run the msCapabilityShow command to verify all switches in the fabric support MS platform service; otherwise, the command fails. Note When security is enabled, this command - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 387
entire fabric. This command deactivates the MS platform service for each switch in the fabric and commits the change to nonvolatile storage. Note When security is enabled, this command can be issued only from the primary FCS switch. This command is supported only in AD0 and AD255 contexts. Note The - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 388
Limitations Operands Examples Topology Discovery Management requires the attached devices which include attached switches to support RNID ELS. The optional operand is as follows: "ALL" Disables the MS topology discovery service throughout the entire fabric. To disable the MS topology discovery - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 389
Operands Examples Topology Discovery Management requires the attached devices which include attached switches to support RNID ELS. This command has the following operand: "ALL" Enables the MS topology discovery service throughout the entire fabric. This operand is optional. To enable the MS - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 390
msTdReadConfig Displays the status of Management Server (MS) topology discovery service. Synopsis mstdreadconfig Description Use this command to check whether or none To display the status of the topology discovery service: switch:admin> mstdreadconfig *MS Topology Discovery is enabled. See - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 391
. The login session gives details of the following: • CP/switch (or console/serial port) used to log in • The IP address of the current login switch:admin> myid Current Switch: switch Session Detail: switch (123.123.123.123) Active Redundant See Also version Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 392
To display information about switches directly connected to the local switch: switch:user> nbrstateshow 2/0 Local Domain ID: 1 Local Port Domain Remote Port State 16 2 48 NB_ST_FULL See Also interfaceShow 2-358 Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 393
slot for bladed systems. Use switchShow to list valid ports. This operand is optional; if omitted, FSPF statistics are reset. When this command is specified with no operand, the statistics are cleared for all interfaces. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-359 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 394
case is for readability. nbrStatsClear Examples To reset the counters on a port: switch:admin> interfaceshow 1/0 idbP = 0x10050a38 Interface attLsaOut = 0 nLsaOut = 0 See Also interfaceShow, portShow, switchShow 2-360 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 395
Use this command to display the NS information for all the devices in the fabric that have either a port World Wide Name (WWN) or a node WWN matching with the given WWN; or have a device PID interpreted as an alias. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-361 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 396
:00:04:cf:9f:26:7e Device type: Physical Target Port Index: 20 Share Area: No Device Shared in Other AD: No Aliases: a320 To display all the device information matching the WWN "20:00:00:e0:8b:01:ce:d3": switch:user> nodefind 20:00:00:e0:8b:01:ce:d3 Remote: Type Pid - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 397
the device information matching the PID "0x020eef": switch:user> nodefind 0x020eef Remote: Type Pid COS PortName NodeName NL 020eef; 3;20:00:00:e0:8b:01:ce:d3;20:00:00:e0:8b:01:ce:d3; Fabric Port Name: 20:0e:00:60:69:51:0b:ba Permanent Port Name: 20:00:00:e0:8b:01:ce:d3 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 398
Physical Device connected to the Nx_Port, using FLOGI to login to the switch Virtual Contrived device by the switch NPV Device connected to the Nx_Port, using FDISC to log in to the switch iSCSI Device connected to the iSCSI port The second part indicates the role of the device. Currently, four - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 399
switch:admin> nsaliasshow { Type Pid COS PortName NodeName TTL(sec) N 021200; 2,3;10:00:00:60:69:00:03:19;30:00:00:60:69:00:03:19; na FC4s: FCIP Fabric Port Name: 20 :02:00:60:69:01:44:22 Permanent Port Name: 10:00:00:60:69:00:03:19 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 400
switch:admin> nsaliasshow -r { Type Pid COS PortName NodeName SCR N 021200; 2,3;10:00:00:60:69:00:03:19;30:00:00:60:69:00:03:19; 3 FC4s: FCIP Fabric Port Name: 20:02:00:60:69:01:44:22 Permanent Port d6;20:00:00:60:69:00:02:d6; 1 Fabric Port Name: 20:03:00:60:69:01:44:22 Permanent Port Name - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 401
with aliases with the -r and -t options: switch:admin> nsaliasshow -r -t { Type Pid COS PortName NodeName SCR N 021200; 2,3;10:00:00:60:69:00:03:19;30:00:00:60:69:00:03:19; 3 FC4s: FCIP Fabric Port Name: 20:02:00:60:69:01:44:22 Permanent Port Name: 10:00:00:60:69:00 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 402
format "x ports supporting FC4 code," where x is the number of ports of a switch:admin> nsAllShow 8 { 0118e2 0118e4 0118e8 0118ef 0214e2 0214e4 0214e8 0214ef 8 FCP Ports } switch:admin> nsAllShow 5 { 011200 021200 2 FC-IP Ports } See Also nsShow, switchShow 2-368 Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 403
manager does not discover new switches or new devices in the fabric. For each remote switch found, the output of 24-bit Fibre Channel address COS A list of classes of service supported by the device PortName The device's port World Wide Name (WWN) NodeName The device's node WWN Permanent Port - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 404
Name: 20:02:00:60:69:00:68:19 Permanent Port Name: 10:00:00:60:69:00:ab:ba Device type: Physical Initiator Switch entry for 4 state rev owner known v320 0xfffc01 Device list: count 0 No entry is found! See Also nsAllShow, nsShow, switchShow 2-370 Fabric OS Command Reference Manual Publication - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 405
The nsAllShow command displays information from all switches. Each line of output displays: Type U for unknown, N for N_Port, NL for NL_Port. PID 24-bit Fibre Channel address. COS List of classes of service supported by device. PortName Device port World Wide Name (WWN). NodeName Device - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 406
login to the switch Virtual Contrived device by the switch NPV Device connected to the Nx_Port, using FDISC to log in to the switch iSCSI Device connected to the iSCSI port The second Unknown(initiator/target)". 2-372 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 407
00:60:69:00:03:19; na FC4s: FCIP Fabric Port Name: 20:02:00:60:69:01:44:22 Permanent Port Name: 10:00:00:60:69:00:03:19 N Port Name: 20:04:00:60:69:01:44:22 Permanent Port Name: 21:00:00:ad:bc:04:6f:70 The Local Name Server has 6 entries } To display local NS information with -r: switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 408
display local NS information with -r and -t: switch:admin> nsshow -r -t { Type Pid COS PortName NodeName SCR N 021200; 2,3;10:00:00:60:69:00:03:19;30:00:00:60:69:00:03:19; 3 FC4s: FCIP Fabric Port Name: 20:02:00:60:69:01:44:22 Permanent Port Name: 10:00:00:60:69:00 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 409
for unknown, N for N_Port, NL for NL_Port Pid The 24-bit Fibre Channel address COS A list of classes of service supported by the device PortName The device's port World Wide Name (WWN) NodeName The device's node WWN Permanent Port Name Physical N_Port or NL_Port WWN DeviceType The device - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 410
:ac;20:00:00:20:37:d9:61:ac; 0 FC4s: FCP [SEAGATE ST318304FC 0005] Fabric Port Name: 20:06:00:60:69:50:06:78 Permanent Port Name: 22:00:00:20:37:d9:61:ac Device type: Physical Target No remote zoned members To display information about all the online devices zoned with the given WWN: switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 411
2 To display each local device's online zoned device data: switch:admin> nszonemember -a Port: 4 Pid: 0xb00400 Aliases: ix360_131_201_6a Zoned Members: 2 devices in the fabric. See Also cfgShow, nscamShow, nsShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-377 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 412
on all switches except the primary FCS. Refer to the Secure Fabric OS Administrator's Guide for more information. A new password must follow these rules: • Have 8 to 40 characters • Must satisfy password policies configured by passwdCfg 2-378 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 413
with no preceding input, accepts the default value (if applicable) and moves to password. To change the password for the admin user: switch:admin> passwd "admin" Changing password for admin Enter new password: Re-type new password: Password changed. Saving password to stable storage. Password - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 414
the minimum ageing period expires. Password contains invalid charactersYou have entered a password that contains invalid characters. Refer to the Fabric OS Message Reference for more information. login, logout, passwdCfg 2-380 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 415
not supported. Use --set to configure the following password policies: • Password strength policy • Password history policy • Password expiration policy • Account lockout policy The password strength automatically unlocked Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-381 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 416
be less than or equal to -minlength value. -history value Specifies the number of past password values that are disallowed when setting a new password. A value of 1 to 24 can be specified. The default value is 1. -minpasswordage value Specifies the minimum number of days that must elapse before - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 417
an administrative action to unlock the account. The default value is 30. Resets all password policies to default values. Displays all the password configuration parameters. To display the current password configuration parameters: switch:admin> passwdcfg --showall passwdcfg.minlength: 8 passwdcfg - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 418
messages displays: Command not supported passwdCfg is not supported when secure mode is -history value must be between 1 and 24. minpasswordage value out of range The - between 0 and 999. invalid password expiration specification The -minpasswordage Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 419
port to the destination port, including all intermediate switches. The command does not make any retry attempts if there is a timeout or failure. It might fail if a switch along the path is busy: for instance, if a switch is performing a warm recovery or if a switch along the path does not support - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 420
ports is requested. The default value for the the port has port A on switch X to port B on switch Y might be different from the path from port B to port specify a sequence of switches, ports, or areas that switches, a sequence of output ports or port path from the input port or area on the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 421
, skipping possible intermediate switches. When using this option, the source route hops must be specified using domain rather than output port. Timeout The maximum time allowed to wait for the response; default is 10 seconds. Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 422
64s) 0 0 0 0 Words 240434036 2294316 2119951 2121767 Frames 20025929 54999 162338 56710 Errors - 4 - 0 Hop In Port Domain ID (Name) Out Port BW Cost 2 14 8 (web228) E - - (output truncated) See Also portStatsShow, switchShow 2-388 Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 423
output from the latest panic dump file available on the switch. If a panic dump file is specified as an SECTION:PD_MISC * WatchDogRegister=0x0 Section=Startup time: Tue Dec 3 16:06:11 UTC 2002 Kernel= 2.4.19 Fabric OS= v4.1.0_j_dist_1103 Made Manual Publication Number: 53-1000240-01 2-389 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 424
for manipulation of these performance monitors. Note This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. Note The execution of this command is subject to Admin Domain - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 425
using commas. To add an end-to-end monitor to blade 1 port 2: switch:admin> perfaddeemonitor 1/2 "0x050200" "0x1182ef" End-to-End monitor number perfAddWriteMonitor, perfClearEEMonitor, perfDelEEMonitor, perfShowEEMonitor Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-391 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 426
Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. operand is optional. The default alias is "IP Frame". Examples To add an IP monitor to a port: switch:admin> perfaddipmonitor 1/4 "IP_MONITOR - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 427
a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. Note operand is optional. The default alias is "SCSI Read". . To add an SCSI read monitor to a port: switch:admin> perfaddreadmonitor 2/4 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 428
filters, SCSI frame monitor, and IP frame monitor. Note This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. Note The execution of this command is subject to Admin Domain - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 429
filters, SCSI frame monitor, and IP frame monitor. Note This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. Note The execution of this command is subject to Admin Domain - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 430
command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. Bloom-based applied (AND-ed) to frame contents. 2-396 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 431
in order to include spaces. This operand is optional. By default, the alias is an empty string. . To add a filter-based monitor for all Extended Link Service requests (R_CTL=0x22 and TYPE=0x01) to a port: switch:admin> perfaddusermonitor 1/4 "4, 0xff, 0x22; 12, 0xff, 0x01" User monitor #0 added - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 432
Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. is optional. The default alias is "SCSI_Write". Examples To add an SCSI Write command monitor to a port: switch:admin> perfaddwritemonitor 2/4 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 433
of performance monitoring from nonvolatile memory. Note This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. Note The execution of this command is subject to Admin Domain - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 434
saved are lost using the perfCfgRestore command. Note This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. Note The execution of this command is subject to Admin Domain - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 435
is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. Note The execution of this command is subject to Admin Domain restrictions that may be in place. Operands Examples none To save the current performance monitoring configuration to firmware: switch:admin - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 436
error counter associated with a specific port and AL_PA, or all such counters on a port. Note This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. Note The execution of this - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 437
monitors clearing. Note This command requires a Brocade Advanced Performance Monitoring license. This command is deprecated; use perfMonitorClear instead. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. Note The execution of this command - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 438
in all filter-based monitors clearing. Note This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. This command is deprecated; use perfMonitorClear instead. Note The - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 439
end-to-end performance monitor from a port, or all such monitors associated with a port. Note This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. Note The execution of this - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 440
-based performance monitor from a port, or all such monitors associated with a port. Note This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. Note The execution of this - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 441
switch: to a port Add monitor on a port Clear filter-based monitors' counters on a port Clear ALPA device's CRC count Delete an end-to-end monitor on port Delete filter Set overall mask for E-to-E monitors Get ALPA CRC count by port and ALPA Show user-defined end-to-end monitors Show filter-based - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 442
monitors (but not ISL monitors) for all the ports in the same quad. Note This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. Note The execution of this command is subject - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 443
mixed case is for readability. perfMonitorClear 2 To clear statistics counters for an ISL monitor: switch:admin> perfmonitorclear --class ISL 1 This will clear ISL monitor on port 1, continue? (yes, y, no, n): [no] y See Also perfAddEEMonitor, perfAddIPMonitor, perfAddReadMonitor, perfAddRWMonitor - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 444
whole ISL Num_ports Number of ports in this ISL (one for a standalone ISL, more for trunks) Num_domains Total number of domains being monitored Domain_count 64-bit cumulative transmit counter for each individual domain 2-410 Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 445
Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports monitor on a port at an interval of every 6 seconds: switch:admin> perfmonitorshow -- Reference Manual Publication Number: 53-1000240-01 2-411 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 446
To display EE monitors on a port: switch:admin> perfmonitorshow --class EE 4/5 There are 7 end-to-end monitor(s) defined on port 53. KEY SID DID OWNER_APP OWNER_IP_ADDR WEB_TOOLS 192.168.169.40 0x000000000000033a 2-412 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 447
monitor information on a port: switch:admin> perfmonitorshow --class ISL 1/1 Total transmit count for this ISL: 1462326 Number of destination domains monitored: 3 Number of ports in this ISL: , perfAddWriteMonitor Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 448
and the AL_PA ID address field must be masked together, to support the FC4-48 blade. On this blade, one bit of the AL_PA ID address field is used with the Area ID address field to identify the upper 32 ports. For example, ports 128 and 256 may be addressed on Domain ID "dd" with - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 449
on a port: switch:admin> perfsetporteemask 1/6 "00:00:00" port will cause ALL EE monitors on this port to be deleted. continue? (yes, y, no, n): [no] y The EE mask on port 6 is set and EE Monitors on this port are deleted See Also perfAddEEMonitor, perfShowEEMonitor Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 450
for all the AL_PA devices on a specified port are displayed. CRC count is a 64-bit counter. The CRC count value is displayed in hexadecimal. Note This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on the SilkWorm 200E, 4100, and 48000 platforms - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 451
Brocade Advanced Performance Monitoring license. This command is deprecated; use perfMonitorShow instead. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports traffic on a port at an interval of every 6 seconds: switch:admin> perfshoweemonitor - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 452
from EE monitors on a port: switch:admin> perfshoweemonitor 4/5 There are 7 end-to-end monitor(s) defined on port 53. KEY SID DID 40 0x00000004d0baed41 0x0000000067229e98 0x0000000000000000 See Also Some platforms do not support counting CRC errors and therefore the CRC error counts will - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 453
command's output. Note This command requires a Brocade Advanced Performance Monitoring license. This command is deprecated; use perfMonitorShow instead. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. Note The execution of this command is - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 454
filter monitor information on a port: switch:admin> perfshowfiltermonitor 2/5 There are 7 filter-based monitors defined on port 21. KEY ALIAS OWNER_APP perfAddSCSIMonitor, perfAddUserMonitor, perfAddWriteMonitor 2-420 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 455
default value of the EE mask is all fields set to "on." Note This command requires a Brocade Advanced Performance Monitoring license. This command is deprecated; use perfMonitorShow instead. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 456
perfShowPortEEMask Examples To display the end-to-end mask on a port: switch:admin> perfshowporteemask 2/4 The EE mask onport 20 is set by application NONE TxSID Domain: on TxSID Area: perfSetPortEEMask, perfShowEEMonitor 2-422 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 457
Root Certificate... If run in secure mode, the following error message is displayed: switch:admin> pkicreate Warning !! Switch is in secure mode. Cannot create new Pki Objects. Exiting... See Also pkiRemove, pkiShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-423 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 458
switch private key, private key pass-phrase, CSR, root certificate, and switch switch:admin> pkiremove WARNING!!! Removing switch. If you want secure mode enabled, you will need to get the switch following error message is displayed: switch:admin> pkiremove This Switch is in secure mode. - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 459
existence of PKI objects, such as switch private key, private key passphrase, CSR, root certificate, and switch certificate. Note The execution of this may be in place. Operands Examples none To view PKI objects: switch:admin> pkishow Passphrase : Exist Private Key : Exist CSR : Exist - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 460
32, and ALL with the --show option. Optional --enc method Operands --auth algorithm --pfs value --dh group --seclife seconds Specifies the encryption algorithm. The default is AES-128 250000000 or 0. The default is 28800. 2-426 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 461
settings: switch:admin> policy --show ike all IKE Policy 1 Authentication Algorithm: SHA-1 Encryption: AES-128 Perfect 128 SA Life (seconds): 28800 IPSec Policy 29 Authentication Algorithm: SHA-1 Encryption: AES-128 SA Life (seconds): 28800 Operation Succeeded Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 462
) a policy: switch:admin> policy ike --delete 10 This policy has been successfully deleted. switch:admin> policy ike --create 10 -enc aes-128 -auth sha-1 SHA-1 Encryption: AES-128 Perfect Forward Secrecy: 0 Diffie-Hellman Group: 1 SA Life (seconds): 28800 To delete a policy: switch:admin> policy ike - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 463
to its slot for bladed systems. Use switchShow to list valid ports. To display the AL_PAs of a port: switch:user> portalpashow 4/14 AL_PA type AL_PA type 0xe2 public 0xe4 public AL_PA type See Also switchShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-429 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 464
of a MARK primitive that is sent and then echoed back to the switch. The supported distance measurement is up to 500 Km. Distance measurement on a link longer than 500 Km might not be accurate. If the connecting port does not support LD mode, is shows "N/A". Remaining Buffers Displays the remaining - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 465
Note: Enter commands in lowercase only; mixed case is for readability. portBufferShow 2 Note The execution of this command is subject to Admin Domain restrictions that may be in place. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-431 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 466
in readability. To display the long distance information a port: switch:user> portbuffershow 17 User Port Lx Max/Resv Buffer Needed Link Remaining Port Type Mode Buffers Usage Buffers Distance Buffers 16 - - 0 - - 17 E L1 - 54 54 50km 18 - - 0 - - 19 - - 0 - - 54 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 467
bladed systems. Use switchShow to list valid ports. This operand is optional; if omitted, information for all ports is displayed. Note Ports that support shared areas are divided into two ports: primary and secondary ports. Primary and secondary ports share the same area. Portcam entries displayed - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 468
CAM utilization for all ports on a switch: switch:user> portcamshow Ports of Slot 9 Port SID used DID used SID free DID free 0 0 0 64 512 1 0 0 64 512 2 0 0 64 512 3 0 0 64 512 4 0 0 64 512 5 0 0 64 512 6 0 0 64 512 7 0 0 64 512 8 0 0 63 511 9 0 0 63 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 469
Note: Enter commands in lowercase only; mixed case is for readability. portCamShow 2 To display the filter CAM utilization for a single port on a switch: switch:user> portcamshow 3/2 Area SID used DID used SID entries DID entries 34 3 1 350400 2b2200 2b1200 220400 SID Free, DID - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 470
the following entities: arp ARP entries. Usage: portcfg arp [slot/][ge]port args. Valid args for arp are: • add ipaddr macaddr Adds static ARP to 7,200; default is 10. If tape pipelining is enabled, minimum value supported is 80. 2-436 Fabric OS Command Reference Manual Publication Number: 53- - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 471
the minimum retransmit time, in milliseconds. time values are 20 to 5,000; default is 100. -n remote_wwn Specifies the remote-side FC port. No other tunnels (IPSec or otherwise) can be configured on the same port. Jumbo frames will not be supported on secure tunnels. Only a single route is supported - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 472
tunnel. retransmissions values are 1 to 16; default is 8. If tape pipelining is enabled, default value is calculated based on the this one. By default, RSCN suppression is disabled to all ports. • --enable Enables the configuration. When enabled, any device change on the port does not generate RSCN - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 473
systems only, specify the slot number of the port to be configured, followed by a slash (/). port Specify the number of the port to be configured, relative to its slot for bladed systems. Use switchShow for a list of valid ports. To add an ARP entry: switch:admin> portcfg arp ge0 add 192.168.255 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 474
16.123.231. 255.255.0.0 192.168.255.25 1 Operation Succeeded To create an FCIP tunnel: switch:admin> portcfg fciptunnel ge0 create 2 192.168.255.2 192.168.255.20 100000 Operation Succeeded To create a mirror portl: switch:admin> portcfg mirrorport 2/4 --enable Please confirm enable of Mirror Port - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 475
To configure a range of ports as RSCN supressed: switch:admin> portcfg rscnsupr 2/4-7 --enable switch:admin> portcfgshow [output from other slots suppressed] Ports of Slot 2 0 1 ON ON ON ON ON EX Port Mirror Port where AN:AutoNegotiate, ..:OFF, ??:INVALID. LM:L0.5 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 476
To reset a GbE port to factory defaults: switch:admin> portcfgdefault 8/ge1 See Also portCfgEPort, portCfgGPort, portCfgLongDistance, portCfgLPort, portCfgPersistentDisable, portCfgPersistentEnable, portCfgShow, portCfgSpeed, portCfgTrunkPort 2-442 Fabric OS Command Reference Manual Publication - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 477
is the default port state. Specify 0 to disable the port from becoming an E_Port. To disable a port from becoming an E_Port: switch:admin> portcfgeport 1/3, 0 To enable a port to become an E_Port: switch:admin> portcfgeport 1/3, 1 See Also portShow, switchShow Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 478
portCfgDefault can also be used to disable EX_Ports. -f fabricid Specify the fabric ID. Valid values are 1-128. -r ratov Specify the R_A_TOV used for port negotiation. Valid values are 2000 - 120000. This operand is only applicable if the "Fabric Parameter" attribute value is not "Auto Negotiate - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 479
2/0: switch:admin> portcfgexport 2/0 Port 2/0 info Admin: enabled State: OK Pid format: core(N) Operate mode: Brocade Native Edge Fabric ID: 16 Front Domain ID: 160 Front WWN: 50:06:06:9e:20:9f:ce:10 Principal Switch: 7 principal WWN: 10:00:00:60:69:c0:05:8a Fabric Parameters - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 480
the slot number of the port to be configured, followed by a slash (/). portnumber Specify the number of the port to be configured, relative from the port. A value of 0 is the default port state. This operand is required. To configure a port as a locked G_Port: switch:admin> portcfggport - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 481
port. If enabling ISL R_RDY mode on a port 02. If a port is ISL R_RDY ports. Before using this mode, the fabric administrator must ensure all fabric-wide parameters are consistent for every switch Switch PID Format fabric.ops.mode.pidFormat Sequence Level Switching R_RDY mode ports are not the port - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 482
Mode is enabled for port 3. Please make sure the PID formats are consistent across the entire fabric. To disable ISL R_RDY mode on a port: switch:admin> portcfgislmode 1/3, 0 See Also configure, portCfgLongDistance, portCfgShow 2-448 Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 483
is shown in parentheses): L0 (0) Specify L0 to configure the port to be a regular switch port. A total of 20 full-size frame buffers are reserved for data traffic, regardless of the port's operating speed; therefore, the maximum supported link distance is 10 Km, 5 Km, or 2.5 Km for the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 484
firmware versions that do not support it. Note If a port is configured as a long distance port, the remaining ports of that port switches and SilkWorm 48000 directors using FC4-16 and FC4-32 port blades, buffer credits are used by all ports on the chip. Buffer-limited port technology allows all ports - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 485
switch port 63 to support a 100 Km link and be initialized using long-distance link initialization protocol: switch:admin> portcfglongdistance 4/15 LS 1 100 switch , portCfgTrunkPort, portCfgShow, portShow, switchShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-451 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 486
; if omitted; the default value of 0 is used. Private devices are supported only on SilkWorm 3250, 3850, and 3900 and directors with FC2-16 and FC2-16 blades. For other switches and blade types, option 1 is blocked. duplex_mode Specify 2 to configure the specified port as a full-duplex L_Port - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 487
in lowercase only; mixed case is for readability. portCfgLPort 2 Examples To configure a port as a locked L_Port: switch:admin> portcfglport 4/15, 1 switch:admin> portcfgshow [output from other slots suppressed] Ports of Slot 4 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Speed AN AN AN - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 488
single CP systems. Up to a maximum of 255 virtual port IDs are allocated per NPIV port. The maximum number of virtual IDs can be configured from 0 to 255 per port. The default value is 126 per port. The number of virtual port IDs per switch also can be configured. See configure for more information - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 489
NPIV capability .. .. .. ON EX Port where AN:AutoNegotiate, ..:OFF, ??:INVALID. LM:L0.5 To disable NPIV functionality on a port: switch:admin> portcfgnpivport 1/3 0 See Also configure, portCfgDefault, portCfgShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-455 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 490
disable or enable configuration does not alter the persistent disable or enable configurations of the ports within the switch. Because the default state of the port is persistently enabled, the persistent disable state is cleared by the portCfgDefault command. This command is not allowed if the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 491
enable a port. Persistently enabled ports remain enabled across power cycles, switch reboots, and switch enables. By default, a port is enabled , portEnable, portCfgPersistentDisable, portCfgShow, portShow, switchShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-457 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 492
switch model and port Port Displays as ON when port is set for trunking or blank (..) when trunking is disabled on the port ON when port is locked as ON when port is locked to port is not allowed to be an E_Port or blank (..) when the port port has ISL R_RDY mode enabled or blank (..) when the port - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 493
has the NPIV capability disabled. This value is set by the portCfgNPIVPort command. It is enabled by default for Condor-based ports and disabled by default for Bloom-based ports. Note The execution of this command is subject to Admin Domain restrictions that may be in place. Operands This command - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 494
a switch: switch:user> portcfgshow Ports of Slot 2 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Speed AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN Trunk Port ON ON ON ON ON ON ON ON ON ON ON Mirror Port Ports of Slot 2 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Speed AN AN AN - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 495
settings for a port: switch:user> portcfgshow 2/16 Area Number: 144 Speed Level: AUTO Trunk Port ON Long Distance Port OFF See Also portCfg, portCfgEPort, portCfgGPort, portCfgLongDistance, portCfgLPort, portCfgNPIVPort, portCfgSpeed, portCfgTrunkPort Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 496
is at fixed speed of 2 Gbit/sec. 4 4-Gbit/sec mode. The port is at fixed speed of 4 Gbit/sec. To set the speed of a port to 2 Gbit/sec: switch:admin> portcfgspeed 2/3, 2 See Also portCfgShow, portShow, switchCfgSpeed 2-462 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 497
for trunking. Specify 0 to disable the port from being trunked. This operand is required. To enable a port for trunking: switch:admin> portcfgtrunkport 1/3, 1 See Also portCfgShow, portShow, switchCfgTrunk, switchShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-463 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 498
values are what the edge switch specifies in the ELP request. If the state is "Not OK", the R_A_TOV and E_D_TOV display "Not Applicable". By default, all EX_Ports are auto-ELP enabled. The port ID format is applicable only when port_mode is "Brocade Native". If the Fabric Parameter attribute - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 499
2/16 Port 2/16 info Admin: enabled State: OK Pid format: core(N) Edge Fabric ID: 16 Front Domain ID: 160 Front WWN: 50:06:06:9e:20:9f:ce:10 Principal Switch: 7 principal WWN: 10:00:00:60:69:c0:05:8a Fabric Parameters: Auto Negotiate R_A_TOV: 9000(N) E_D_TOV: 2000 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 500
ports. Synopsis portcmd --ipperf [slot/]geport -s src_ip -d dst_ip -S | -R [-i interval] [-p port port. Currently we do not support end port number of the GbE port on the blade. --ipperf [slot/]geport -s src_ip -d dst_ip -S | -R [-i interval] [-p port port Specifies the TCP port number for - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 501
the --ipperf command with -i option or the default (30s). BW This is the bandwidth measured and payload. Note: There is limited support for black hole PMTU detection. If the Jumbo PMTU interfaces on the GbE port. Valid arguments include: Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 502
IP interfaces on the GbE port. Valid arguments include: -s type of service in the ping request. The default is 0 default is 64 bytes. The total size, including ICMP/IP headers (28 bytes without IP options) cannot be greater than the IP MTU configured on the Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 503
192.168.100.40: bytes=40 rtt=0ms ttl=64 Ping Statistics for 192.168.100.40: Packets: Sent = 4, Received = 4, Loss = 0 (0 loss) Min RTT = 0ms, Max RTT = 0ms Average = 0ms To set the path characteristic to source mode on the remote host: switch:admin> portcmd ipperf 4/ge0 -s 192.168.100.50 -d 192 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 504
command to set the debug level and verbose level of port modules. Note The execution of this command is subject to port modules; valid values are 1 to 5. To set debug level and verbose level of port modules: switch:admin> portdebug 3 4 See Also dbgShow 2-470 Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 505
its slot for bladed systems. Use switchShow to display a list of valid ports. To disable a port: switch:admin> portdisable 2/4 See Also portCfgPersistentDisable, portCfgPersistentEnable, portEnable, portShow, switchShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-471 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 506
its slot for bladed systems. Use switchShow to display a list of valid ports. To enable a port: switch:admin> portenable 2/4 See Also portCfgPersistentDisable, portCfgPersistentEnable, portDisable, portShow, switchShow 2-472 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 507
Description Use this command to display an error summary for all ports. The display contains one output line per port and shows error counters in ones, thousands (k), or millions (m). may be in place. Operands none Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-473 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 508
ports on a switch: switch 16: 0 0 - 0 0 0 0 - 0 - - - - 17: 0 0 - 0 0 0 0 - 0 - - - - 18: 0 0 - 0 0 0 0 - 0 - - - - 19: 0 0 - 0 0 0 0 - 0 - - - - 20: 0 0 - 0 0 0 0 - 0 - - - - 21: 0 0 - 0 0 0 0 - 0 - - - - 22: 0 0 - 0 0 0 0 - 0 - - - - 23: 0 0 - 0 0 0 0 - 0 - - - - 24 Reference Manual Publication - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 509
in place. Operands none Examples To display the port status for all ports in the switch: switch:user> portflagsshow Slot Port SNMP Physical Flags 1 0 Online In_Sync PRESENT E_PORT G_PORT LOGIN LED ACCEPT Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-475 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 510
2 Note: Enter commands in lowercase only; mixed case is for readability. portFlagsShow See Also portShow, switchShow 2-476 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 511
the following operands: -npass count Specify the number of times to perform this test. The default value is 10. -ports itemlist Specify a list of user ports to run the test. If omitted, all the active ports in the switch are assumed. For more information, refer to the itemList command. To test - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 512
command is subject to Admin Domain restrictions that may be in place. Operands Examples none To clear the port log: switch:admin> portlogclear switch:admin> portlogshow port log is empty See Also portLogDump, portLogShow 2-478 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 513
is subject to Admin Domain restrictions that may be in place. Operands Examples none To display the current port log configuration: switch:admin> portlogconfigshow max portlog entries = 8192 See Also portLogResize Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-479 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 514
log facility. Note The execution of this command is subject to Admin Domain restrictions that may be in place. Operands Examples None. To display the port log facility: switch:admin> portlogdisable See Also portLogEnable 2-480 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 515
be displayed. This operand is optional. To display the port log for a port: switch:user> portlogdump 20 time task event port cmd args 08:35:27.899 tShell pstate 14 OL1 08:35:27.899 tReceive pstate 14 LR2 08:35:27.916 tReceive pstate 14 AC 08:35:28.416 interrupt scn 14 1 08:35 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 516
2 Note: Enter commands in lowercase only; mixed case is for readability. portLogDump See Also portLogClear, portLogShow, upTime 2-482 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 517
page. Port logs are circular log files in the switch firmware, which can save up to 8,192 entries. Refer to portLogConfigShow to display the current port log :28.466 tReceive pstate 14 LR3 08:35:28.466 tReceive pstate 14 AC 08:35:28.483 tFabric Tx 14 96 02fffffd,00fffffd,0006ffff,11100060 08:35 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 518
log facility. Note The execution of this command is subject to Admin Domain restrictions that may be in place. Operands Examples None. To enable the port log facility. switch:admin> portlogenable See Also portLogDisable 2-484 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 519
log events. Synopsis portlogeventshow Description Use this command to display information about the ID associated with the various port log events. The Disabled field indicates if the port log for that event ID is disabled (1) or enabled (0). Note The execution of this command is subject to Admin - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 520
Display information about port log events: switch:admin> portlogeventshow ID 16 reject 0 17 busy 0 18 ctin 0 19 ctout 0 20 errlog 0 21 loopscn 0 22 create 0 23 debug 1 24 switch 0 52 ficonq 0 53 routing 0 2-486 Fabric OS Command Reference Manual Publication Number: - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 521
Note: Enter commands in lowercase only; mixed case is for readability. portLogEventShow 2 See Also portLogTypeDisable, portLogTypeEnable Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-487 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 522
24-bit Port ID of the attached device. WorldWideName The port's World Wide Name. credit The credit for this login as appropriate. This is BB (buffer-to-buffer) credit for FLOGIs and EE (end-to-end) credit for PLOGIs. df_sz The default frame size for this login. cos Class of Services supported - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 523
place. Operands Examples This command has the following operand: lvl Specify either 0 to clear or 1 to set the debug_pdisc_flag. To set the pdisc_flag: switch:admin> portlogpdisc 1 PDISC log setting = 1 See Also none Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-489 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 524
that might disable the port log facility. Note The execution of this command is subject to Admin Domain restrictions that may be in place. Operands Examples none To enable the port log: switch:admin> portlogreset See Also none 2-490 Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 525
The valid range of values is 32,768 to 65,536 for Silkworm 48000 Director and Silkworm 7500 Switch, and 8,192 to 16,384 for all others. To resize the portlog: switch:admin> portlogresize 12288 See Also portLogConfigShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-491 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 526
as portLogDump, but it enables you to press Enter after each page of output. Port logs are circular log files in the switch firmware, which can save up to 32,768 entries. Refer to portLogConfigShow to display the current port log size. Once the log is full, the newest log entries delete the oldest - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 527
an exchange xerr Exchange error xstate Exchange state payload Frame payload Port Displays the port number that logged the event. Cmd Defined by the event. loop master BMP Loop init completed, FL_Port in MONITORING state OLD Port transited to the OLD_PORT state TMO Loop init times out Args - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 528
busy FC-PH busy reason ctin Argument 0 is divided into two 16-bit fields: [A] a bit map indicating whether subsequent args are 0003 means arguments 1 and 2 are valid). [B] the CT-based service command code. Argument 1 is the first word of the CT payload Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 529
OLS State Retry loop init Start loop after gaining sync Restart loop after port reset LIP when a loop hangs Restart loop if LIP received when sending out AC state Restart loop if loop not empty but E_Port loopback LIP as requested by the LINIT ELS received LIP as requested by the LPC ELS received - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 530
displayed by this command, refer to the Fabric OS Administrator's Guide. Note The execution of this command is subject to Admin port log for a port: switch:user> portlogshow 24 time task event port cmd args 17:05:30.384 PORT Rx 0 40 02fffffd,00fffffd,08fbffff,14000000 17:05:30.384 PORT - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 531
of the port to display. To display a port log for port 14: switch:user> portlogshowport 14 time task event port cmd args 08:35:28.483 tFabric scn 14 0 08:35:27.899 tShell pstate 14 OL1 08:35:27.899 tReceive pstate 14 LR2 08:35:27.916 tReceive pstate 14 AC 08:35:28 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 532
the following operand: id Specify a nonzero value that corresponds to the port log type to be disabled. The values corresponding to different log port log: switch:admin> portlogtypedisable 2 See Also portLogDisable, portLogEventShow, portLogTypeEnable 2-498 Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 533
The values corresponding to different log types can be obtained by running portLogEventShow. To enable event 2 to report to the port log: switch:admin> portlogtypeenable 2 See Also portLogEventShow, portLogTypeDisable Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-499 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 534
external loopback cable) can be used to determine which components of the switch are faulty. Note The execution of this command is subject to Admin ports specified will be relative to this slot number. The default is set to 0 and designed to operate 2-500 Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 535
By default, all of the blade ports in the specified slot (--slot) are used. See itemList for more information. To run a functional test of a connection: switch:admin> portloopbacktest -ports 1/10-1/20 -nframes 1 -lb_mode 1 Running Port Loopback Test .... passed. Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 536
to the Fabric OS Message Reference for more information. See Also camTest, centralMemoryTest, cmemRetentionTest, cmiTest, crossPortTest, itemList, portRegTest, spinSilk, sramRetentionTest 2-502 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 537
To display all configured mirror ports on a switch use the portCfgShow command. Note The port mirroring feature is only supported on the following platforms: SilkWorm 4100, SilkWorm 4900, SilkWorm 7500, and SilkWorm 48000 Option 5. Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 538
between two local switch ports: switch:admin> portmirror --delete 0x011400 0x012400 To delete a port mirror connection between a local switch port and a remote switch port: switch:admin> portmirror --delete 0x011400 0x240400 2-504 Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 539
2 To display port mirror connections: switch:admin> portmirror --show Number of mirror connection(s) configured: 2 Mirror_Port SID DID State 10/12 0x791800 0x791900 Defined 10/15 0x791a00 0x799300 Enabled See Also portCfgShow Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 540
port name. Like all other configurable port attributes, port ports. name Specify a port name. The port name is a character string up to 32 the current port name is port names of all ports present are displayed. To name to a port Tape drive 8: switch:admin> portname 1/3, "Tape drive 8" switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 541
ports on the switch. Data displays in 8 or 16 columns, one column per port plus one column that displays the total for these ports Default output on the device port. Examples To display port throughput for a switch: switch:user> portperfshow 20 0 1 2 3 Manual Publication Number: 53-1000240-01 2-507 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 542
for a 32-bit register command is supported only on ports specified are relative to this slot number. The default is 0. -ports itemlist Specify a list of blade ports to test. By default, all the blade ports default value is to disable this mode. 2-508 Fabric OS Command Reference Manual Publication Number: - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 543
run a bit write/read test of the ASIC SRAMs and registers: switch:admin> portregtest -ports 1/0-1/15 Running Port Register Test .... Test Complete: "portregtest" Pass 1 of 1 Duration , spinSilk, sramRetentionTest Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-509 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 544
contains the port number on switch. The format of ports_bitmap is the same as the external unicast routing table.. Broadcast routing table Displays how the specified port 16 set (value 0x10000), indicating this port always routes broadcast frames to the embedded port, for handling by the firmware - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 545
Enter commands in lowercase only; mixed case is for readability. portRouteShow 2 Examples To display the routing tables for a port: switch:user> portrouteshow 4/15 port address ID: 0x02bf00 external unicast routing table: 1: 0x4 (vc=3) 2: 0x10000 (vc=0) internal unicast routing table: 60: 0x8000 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 546
port Description Use this command to display general or switch- and port-specific status information for the specified port the switch model and port type. port by the command of the same name. portHealth Current health of the port port at port Port type and revision numbers. portState Port port - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 547
to the reference signal. portScn Last State Change Notification for port. port generation number Port generation number for the last offline state change. portId 24-bit port ID. portIfId User port's interface ID. portWwn Port WWN. portWwn of devices(s) connected WWNs of connected devices - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 548
passwords are configured both on the router and the edge switch, the security type is displayed as "DH_CHAP". DH-CHAP is the only supported database in the fabric and all switches must be the same, or else the port is disabled. After the general information Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 549
only, specify the slot number of the port to be configured, followed by a slash (/). [ge]port Specify the port number to be displayed, relative to its slot for bladed systems. See switchShow for a list of valid ports. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-515 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 550
Frjt: 0 Fbsy: 0 To display IP interfaces on a GbE port: switch:admin> portshow ipif ge0 GE Port 0/ge0 Interface IP Address NetMask MTU 0 192.168.255.20 255.255.255.0 1500 1 192.168.255.21 255.255 255.0 1500 2-516 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 551
switch:admin> portshow fciptunnel ge1 0 -params Port: ge1 Tunnel ID 0 Remote IP Addr 192.168.255.200 Local IP Addr 192.168.255.100 Remote WWN Not Configured Local WWN 10:00:00:05:1e:35:16 lifetime total) [Output Truncated] Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-517 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 552
switch:admin> portshow fciptunnel ge1 0 -perf Port: ge1 Tunnel ID 0 Remote IP Addr 192.168.255.200 Local IP Addr 192.168.255.100 Remote WWN Not Configured Local WWN 10:00:00:05:1e:35:16 output Bytes 56 Bps 30s avg, 128 Bps lifetime avg 0 packets lost ( Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 553
on a GbE port: switch:admin> portshow iproute ge0 GE Port 0/ge0 IP Address Mask Gateway Metric Flags 192.168.255.0 255.255.255.0 192.168.255.20 0 Interface, , 172.16.123.231 255.255.0.0 192.168.255.25 1 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-519 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 554
2 Note: Enter commands in lowercase only; mixed case is for readability. portShow To display iSCSI Port WWN and Sessions: switch:admin> portshow isci 2/ge0 GE Port 2/ge0 Port WWN Sessions 50:06:06:9e:40:09:a2:00 0 See Also authUtil, portCfg, portCfgLongDistance, portLoginShow, portName, - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 555
64-bit hardware statistics for a port. Synopsis portstats64show [slotnumber/]portnumber Description Use this command to display the following hardware statistics for a port. Byte rate (Bytes/sec). stat64_rateRxPeakByte Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-521 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 556
. Operands This command has the following operands: slotnumber For bladed systems only, specify the slot number of the port to be displayed, followed by a slash (/). portnumber Specify a port number to be displayed, relative to its slot for bladed systems. Use switchShow to display a list of - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 557
readability. portStats64Show 2 Examples To display the 64-bit hardware statistics for a port: switch:user> portstats64show 4/15 stat64_wtx 0 top_int : 4-byte words transmitted See Also portStatsClear, portStatsShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-523 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 558
to be cleared, relative to its slot for bladed systems. Use switchShow to display a list of valid ports. To clear the statistics for a port: switch:admin> portstatsclear 4/15 See Also portStats64Show, portStatsShow 2-524 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 559
geportnumber [ipaddress | tunnelnumber] Description Use this command to display port hardware statistics counters. Some counters are platform and port specific and display only with those platforms and ports. All statistics have a maximum 32-bit value of 4,294,967,295. stat_wtx stat_wrx stat_ftx - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 560
Class 3 frames discarded due to zone mismatch. CRC error with good EOF (platform and port specific). Invalid ARB. Number of times the FL_Port entered OPEN state. Number of times statistics for the specified FCIP tunnel. 2-526 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 561
portStatsShow 2 Examples To display the basic set of statistics for a port: switch:admin> portstatsshow 13 stat_wtx 0 stat_wrx 0 stat_ftx 0 stat_frx 0 stat_c2_frx abort frames 0 GE overruns 0 GE Fifo overflow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-527 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 562
fcip_entity pkts 0 ve to fcip_entity bytes To display port statistics for all IP addresses, slot 8, and GbE port 1: switch:admin> portstatsshow ip 8/ge1 ip_err_crc ip_err_hdr_cksum ip_err_tcp_data_chksum 0 , portShow 2-528 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 563
ports. Both ports must be disabled prior to executing this command and the port previous port swap, execute portSwap again on the same two ports. valid ports. slotnumber2 For bladed systems only, specify the slot number of the second port whose between a pair of ports: switch:admin> portswap 1/3 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 564
of this command is subject to Admin Domain restrictions that may be in place. Operands Examples none To disable the portswap feature: switch:admin> portswapdisable See Also portSwap, portDisable, portEnable, portShow, portSwapEnable, portSwapShow, switchShow 2-530 Fabric OS Command Reference - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 565
execution of this command is subject to Admin Domain restrictions that may be in place. Operands Examples none To enable the portswap feature: switch:admin> portswapenable See Also portSwap, portDisable, portEnable, portShow, portSwapDisable, portSwapShow, switchShow Fabric OS Command Reference - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 566
to display the enabled state of the portswap feature, as well as port and area information for those ports whose area number id different from the default area number. The default area number of a port is same as its switch port number. Note The execution of this command is subject to Admin Domain - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 567
to Admin Domain restrictions that may be in place. Operands This command has the following operands: -ports itemlist Specify a list of user ports to test. By default, all the user ports in the switch are tested. Refer to itemList help pages for further details. Fabric OS Command Reference - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 568
port) to execute this test. Default value is 20 are supported ports. To run a functional test on an active switch: switch:admin> porttest -ports 1/1-1/3 See Also crossPortTest, fportTest, loopPortTest, portLoopbackTest, portTestShow, spinFab, stopPortTest 2-534 Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 569
ports to test. By default, all the user ports in the current slot will be assumed. Refer to itemList help pages for further details. To display information from portTest: switch:admin> porttestshow 1 Port : 0 ErrorCode: 0 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-535 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 570
2 Note: Enter commands in lowercase only; mixed case is for readability. portTestShow See Also crossPortTest, fportTest, loopPortTest, portLoopbackTest, portTest, spinFab, stopPortTest 2-536 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 571
requires a Brocade Advanced Zoning license. Note The execution of this command is subject to Admin Domain restrictions that may be in place. Operands Examples none To display the zone membership information of ports: switch:user> portzoneshow [OUTPUT TRUNCATED] PORT: 160 (160) Offline PORT: 161 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 572
order. Whenever a power supply goes out of service or a field-replaceable unit (FRU) is inserted CP boards' processors to cease execution of the firmware. In this situation, all operation of the system format of the display varies, depending on the switch model and the number of slots present. Note - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 573
is for readability. powerOffListSet 2 Examples To modify the power-off list order: switch:admin> powerofflistset Slot Current POL 10 1st 9 2nd 8 3rd 7 4th , psShow, slotPowerOff, slotPowerOn, slotShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-539 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 574
power causes the CP boards' processors to cease executing the firmware. In this situation, all operation of the system terminates Examples none To display the slot power off list order: switch:admin> powerofflistshow Slot 10 will be powered off 1st Slot Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 575
that may be in place. Operands Examples none To view the status of the power supplies: switch:admin> psshow Power Supply #1 is OK DELTA DPS-1001AB-1E 23000000601 S1 Power Supply #2 is See Also chassisShow, fanShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-541 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 576
displayed on the switch's console. Only telnet session will be suppressed. By default, quiet mode is disabled, and all switch tasks may send and then enable it: switch:admin> quietmode quietMode: On Usage: quietMode 0|1 0: to turn it off 1: to turn it on switch:admin> quietmode 0 Committing - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 577
ports become inactive until the new active CP reinitializes these ports. If this switch is part of a fabric, reboot the switch so that the remaining switches reboot the CP: switch:admin> reboot Rebooting... See Also fastboot, switchReboot Fabric OS Command Reference Manual Publication Number: 53- - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 578
To display a list of routing-related commands: switch:admin> routehelp bcastShow dlsShow fspfShow interfaceShow iodShow LSDbShow nbrStateShow neighbor's summary information Print paths to domain(s) Print port's unicast routing info See Also bcastShow, interfaceShow, uRouteShow 2-544 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 579
-F][-h ipaddress][-u user_name | -a][-p password] [-d remote_directory] To remove core name for the host name; default is anonymous. -p password Specify a password for the user name. -a Examples To list all core files in a CP: switch:admin> savecore -l /core_files/panic/core.873 /core_files - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 580
core.873: 1.12 kB 381.90 B/s Files transferred successfully! To FTP selected core file directories: switch:admin> savecore -h 192.168.204.188 -u jsmith -d core_files_here -p password -f /core_files/zoned/,/mnt/core_files/nsd/ /core_files/zoned//core.1234: 1.12 kB 382.60 B/s /core_files/zoned - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 581
using the savecore management utility: switch:admin> savecore following 1 /panic Done! switch:admin> switch:admin> savecore No core using the savecore management utility: switch:admin> savecore following 1 directories Directory [.]? brcd Password core_files/zoned/core.8323: Files - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 582
only; mixed case is for readability. saveCore To remove core files from a selected directory: switch:admin> savecore following 2 directories contains core files: [ ]0: /core_files/nsd [ ]1: / /zoned Done! See Also none 2-548 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 583
staff. The information displayed might not be supported between releases and is subject to change arbitrarily. Operands none Examples To display the size of the active security database: switch:admin> secactivesize Size of security active data: 35 bytes (Max 262144 bytes) See Also secDefineSize - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 584
next authentication request. The configuration applies to a switch instance only. Note A Brocade Security license is required to run this command WWN: switch:admin> secauthsecret --show WWN DId Name 10:00:00:60:69:80:5b:e8 1 switch 2-550 Fabric OS Command Reference Manual Publication - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 585
. If switch is configured to do DH-CHAP, it is performed whenever a port or a switch is enabled switch to segment from the fabric. Do want to remove secret key database? (yes, y, no, n): [no] y Deleting secret key database... Done. switch:admin> See Also none Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 586
Generate a certificate signing request (CSR). • Delete a CSR. • List the certificates present in the switch. • Display the contents of a certificate/CSR. • Delete a specific certificate. • Configure SSL CSR and all other 2-552 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 587
switch. This is second step for setting up third-party certificates in the switch. To generate a CSR, the admin must answer a series switch. delcsr Deletes the CSR in the switch. showcsr Displays the contents of the CSR in the switch on to the switch. Use this for switch switch 3. Reset the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 588
suffix): filename Enter Login Name: login Enter Password: password Success: imported certificate [certificate file name]. Certificate switch:admin> seccertutil showcsr To display contents of a certificate: switch:admin> seccertutil show certificate file name 2-554 Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 589
Note: Enter commands in lowercase only; mixed case is for readability. secCertUtil 2 See Also none Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-555 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 590
. The information displayed might not be supported between releases and is subject to change arbitrarily. Operands none Examples To display the size of the defined security database: switch:admin> secdefinesize Size of security defined data: 35 bytes (Max 262144 bytes) See Also secActiveSize - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 591
.148 "nonfcs" Backup 10:00:00:60:69:00:12:53 2 Ready 192.168.100.147 "backup" Primary 10:00:00:60:69:22:32:83 3 Ready 192.168.100.135 "switch" Secured switches in the fabric: 3 See Also secPolicyDump, secPolicyShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-557 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 592
switch. Operands Examples none To enable a backup FCS switch to take over as the primary FCS switch: switch:admin> secfcsfailover This switch is about to become the Primary FCS switch. All transactions of the current Primary FCS switch OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 593
• The active and defined sizes of the security database This command is intended strictly for debugging purposes by technical support staff only. The information displayed might not be supported between releases and is subject to change arbitrarily. Operands none Fabric OS Command Reference - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 594
Examples To view the current security state: switch:admin> secglobalshow 15:22:01 1024 Recv sysmod SCN state 0x20 : Enf IP change ret 0 15:24:49 1024 RecvQ msgt 0x1, arg 0x0 See Also secActiveSize, secDefineSize 2-560 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 595
to all switches Shows members of one or more policies Displays all members of existing policies Resets security statistics Displays security statistics Sets temporary password Resets temporary password Aborts current transaction Resets version stamp See Also none Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 596
This command can be issued only in secure mode and only from the primary FCS switch. Operands Examples none To disable secure mode: primaryfcs:admin> secmodedisable Please enter current admin account password: Warning!!! About to disable security. ARE YOU SURE (yes, y, no, n): [no] y See Also - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 597
FCS_POLICY. • Distributing the security database to all switches in the fabric. • Resetting the root, factory, admin, and user account passwords on all FCS switches in the fabric. • Resetting the admin and user account passwords on all non-FCS switches in the fabric. • Disabling the root and factory - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 598
cannot be used when secure mode is enabled. Passwords of such user accounts can be changed only switches present in the fabric when the command is executed. DCC policies are populated with the devices present in the fabric when the command is executed, locking down devices on a per port basis. Ports - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 599
command, security is enabled in the fabric with all switches being FCS, all switches having passwords identical to that of the primary FCS and SCC, becomes interactive and the user is prompted to enter FCS switch members and passwords. If the --currentpwd option is not used, the session becomes interactive and - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 600
be required for proper support of the switch. Please ensure the Root and Factory passwords are documented in a secure location. Recovery of a lost Root or Factory password will result in fabric downtime. Changing password for root New FCS switch root password: Re-type new password: (output truncated - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 601
fabric. PLEASE NOTE: On successful completion of this command, login sessions may be closed and some switches may go through a reboot to form a secure fabric. Non-FCS admin password will be set the same as FCS admin password. ARE YOU SURE (yes, y, no, n): [no] y Please enter current admin account - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 602
a fabric. Operands none Examples To display the current secure mode of a fabric: switch:admin> secmodeshow Secure Mode: ENABLED. Version Stamp: 9182, Wed Mar 17 16:37:01 2004. POS Primary WWN DId swName. 1 Yes 10:00:00:60:69:00:00:5a 21 switch47. 2 No 12:00:00:60:60: - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 603
FCS switch admin password: Re-type new password: Login sessions with password changed will be terminated. Password for non-FCS admin account has been changed successfully. See Also passwd, secModeDisable, secModeEnable, secModeShow, secTempPasswdSet Fabric OS Command Reference Manual Publication - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 604
When secure mode is enabled, this command can be issued only from the primary FCS switch. Operands Examples none To abort all changes that have not been saved to flash memory , secPolicyRemove, secPolicySave, secStatsShow 2-570 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 605
command activates the security policy set on all switches in the fabric and can be issued only from the primary FCS switch. In non-secure mode, if there are secPolicyDump, secPolicyRemove, secPolicySave, secPolicyShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-571 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 606
Router. Note When secure mode is enabled, this command can be issued only from the primary FCS switch. Operands This command has the following operands: "name" Specify the name of an existing policy to not have to be 2-572 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 607
does not stop access to the switch. The device is specified with a WWN string. The switch and port combination must be in the following format: can be specified using WWN, domain, or switch name. can be specified by port numbers separated by commas and enclosed - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 608
ports. [*] Selects all ports on the switch and devices currently attached to those ports. OPTIONS_POLICY members "NoNodeWWNZoning" is the only option. To add a member to the MS_POLICY using the device WWN: primaryfcs:admin> secpolicyadd "MS_POLICY", "12:24 Reference Manual Publication Number: - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 609
When secure mode is enabled, this command can be issued only from the primary FCS switch. Operands This command has the following operands: "name" Specify the name of a The specified policy name must be capitalized. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-575 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 610
associated with a specific switch and port combination. An empty DCC_POLICY does not stop access to the switch. The device is specified with a WWN string. The switch and port combination must be in the following format: 2-576 Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 611
to specify the port values: (1-6) Selects ports 1 through 6. (*) Selects all ports on the switch. [3, 9] Selects ports 3 and 9 and all devices attached to those ports. [1-3, 5] Selects ports 1 through 3 and 5 and all devices attached to those ports. [*] Selects all ports on the switch and devices - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 612
", "192.168.5.0" TELNET_POLICY has been created. primaryfcs:admin> See Also fddCfg, distribute, secPolicyAbort, secPolicyActivate, secPolicyAdd, secPolicyDelete, secPolicyDump, secPolicyRemove, secPolicySave, secStatsShow 2-578 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 613
. Note When secure mode is enabled, this command can be issued only from the primary FCS switch. Operands This command has the following operands: "name" Specify the name of a security policy managed with this command. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-579 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 614
deleted, fabric-wide switch access through that method is unrestricted. Examples To delete an existing security policy: switch:admin> secpolicydelete "MS_POLICY secPolicyDump, secPolicyRemove, secPolicySave, secPolicyShow 2-580 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 615
databases. Note When secure mode is enabled, this command can be issued from all the FCS switches in the fabric. Operands This command has the following operands: "listtype" Specify which database SCC and DCC policies. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-581 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 616
.52.11 ACTIVE POLICY SET TELNET_POLICY IpAddr 192.155.52.0 See Also , secPolicyAbort, secPolicyActivate, secPolicyAdd, secPolicyCreate, secPolicyDelete, secPolicyRemove, secPolicySave, secPolicyShow 2-582 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 617
in the FCS list. Only one FCS can be moved at a time. The first FCS switch in the list that is also present in the fabric is the primary FCS. If no , secPolicyDump, secPolicyRemove, secPolicySave, secPolicyShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-583 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 618
When secure mode is enabled, this command can be issued only from the primary FCS switch. Operands This command has the following operands: "name" Specify the name of an using IP address, WWN, domain, or switch name. 2-584 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 619
all ports on the switch. [3, 9] Selects ports 3 and 9 and all devices attached to those ports. [1-3, 5] Selects ports 1 through 3 and 5 and all devices attached to those ports. [*] Selects all ports on the switch and devices currently attached to those ports. Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 620
policy: switch:admin> secpolicyremove "MS_POLICY", "12:24:45:10:0a:67:00:40" Member(s) have been removed from MS_POLICY. See Also secPolicyAbort, secPolicyActivate, secPolicyAdd, secPolicyCreate, secPolicyDelete, secPolicyDump, secPolicySave, secStatsShow 2-586 Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 621
all switches in the fabric: switch:admin> secpolicysave secpolicysave command was completed successfully. See Also fddCfg, secPolicyAbort, secPolicyActivate, secPolicyAdd, secPolicyCreate, secPolicyDelete, secPolicyDump, secPolicyRemove, secStatsShow Fabric OS Command Reference Manual Publication - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 622
command displays the security policy database in effect on all the FCS switches in the fabric and can be issued from all FCS switches. In non-secure mode, this command displays the security policy SCC and DSS policies. 2-588 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 623
IpAddr 192.155.52.0 To display all security policies from defined databases: switch:admin> secpolicyshow "defined DEFINED POLICY SET FCS_POLICY Pos Primary WWN DId swName secPolicyRemove, secPolicySave Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-589 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 624
0. This command can be issued to any switch. If issued on the primary FCS switch, this command can reset security statistics for any or all switches in the fabric. Operands This command has the are grouped together. 2-590 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 625
fabric or specify a list of domains, separated by semicolons. This operand is optional and the default value is the local switch. To reset all statistics on the local switch: switch:admin> secstatsreset About to reset all security counters. ARE YOU SURE (yes, y, no, n):[no] y Security statistics - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 626
be issued to any switch. If issued on the primary FCS switch, this command can retrieve and display the security statistics for any or all switches in the fabric. Note • SLAP FAIL • SLAP_BAD_PKT • TS_OUT_SYNC • NO_FCS 2-592 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 627
. This operand is optional and the default value is the local switch. To display the MS_POLICY statistics on the local switch: switch:admin> secstatsshow "MS_POLICY" Name Value MS 20 To display statistic information for TELNET_POLICY for all switches in the fabric (example from an - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 628
account on domain 2 ARE YOU SURE (yes, y, no, n): [no] y Login sessions with password changed will be terminated. Temporary password of each account on domain 2 has been successfully reset. (if switch is non fcs switch it will further display) Root and factory accounts on domain 2 have been disabled - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 629
same level account on the primary FCS switch. The password setup on the target is not persistent and will be reset to the secure fabric-wide setting when this target switch is rebooted or when secTempPasswdReset is run on primary FCS switch. Each switch has four accounts: root, factory, admin, and - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 630
management application problems. This command switch:admin> sectransabort Transaction has been aborted. See Also secPolicyAbort, secPolicyActivate, secPolicyAdd, secPolicyCreate, secPolicyDelete, secPolicyDump, secPolicyRemove, secPolicySave, secStatsShow 2-596 Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 631
to 0: switch:admin> secversionreset About to reset version stamp to 0. Are you sure (yes, y, no, n):[no] y done. Security Policy Version Stamp has been set to 0. See Also secFabricShow, secModeDisable, secModeEnable, secModeShow, secTransAbort Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 632
power supply status and readings from sensors located on the switch. The actual location of the sensors varies, depending on the switch type. Note The execution of this command is subject Absent See Also fanShow, tempShow 2-598 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 633
messages to the serial console. By default, no debug messages are displayed. Note response time. The set of supported modules and their current debug levels (0 to 9). A 0 value (default) specifies that no messages are to NS to value 3: switch:admin> setdbg NS 3 switch:admin> dbgshow NS Module - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 634
varies but most commonly consists of disabling the ports defined with diagEsdPorts when spinSilk or other functional SilkWorm chassis; however, the command is not supported by the SilkWorm platform and does not effect the ESD mode: switch:admin> setesdmode -show Esd Mode is 0 (Disabled - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 635
ports without media installed are not tested. Normally, tests such as crossPortTest or spinSilk fail if any port is not operating properly, but with media mode enabled, the functional tests are skipped on ports is optional. To enable the media mode: switch:admin> setgbicmode 1 GBIC mode is now - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 636
ports without media installed are not tested. Normally, tests such as crossPortTest or spinSilk fail if any port is not operating properly, but with media mode enabled, the functional tests are skipped on ports optional. To display the media mode: switch:admin> setmediamode -show Media mode is - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 637
to enable or disable modem dial-in to a CP on those systems that support modem dialin. When modem dial-in is enabled, you can log in to each modem port of CP0 and CP1. These modems connect to the telephone outlet through a RJ-11 Y-adapter and standard Manual Publication Number: 53-1000240-01 2-603 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 638
Adapter Optional Handset DB-25M to DB-9F Modem Cable (one per CP Card) Modem Port on CP Card (one per CP Card; RS-232 port d 14 c 13 b 12 a 11 d 10 c 9 b 8 a 7 d 6 c 5 b 4 a 3 d 2 c 1 b 0 a ! ! RS - 232 RS - 232 IOIOI IOIOI Link 10/100 Mb/s Active CP Link 10/100 Mb/s Active CP ! 15 switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 639
ports without media installed are not tested. Normally, tests such as crossPortTest or spinSilk fail if any port is not operating properly, but with media mode enabled, the functional tests are skipped on ports disable, and then display the media mode: switch:admin> setsfpmode 0 SFP mode is now - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 640
single port loopback port loopback for M->M connected ports. This might be useful to isolate internal switch problems from SFP problems connections between pairs of M->M ports are chosen to exercise the of M->M ports. Any ports that are is not supported by the port loopback: switch:admin - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 641
filter the display of the debug message to the serial console. By default, no debug messages are displayed. Note The execution of this command is To set the verbose level of module named NS to value 3: switch:admin> setverbose NS 3 switch:admin> dbgshow NS Module NS, debug level = 0, verbose level - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 642
information for all available SFPs. For Finisar "smart" SFPs, five additional fields display: module temperature, voltage, received optical power, transmitted optical power (longwave only), and laser diode drive current. If the SFP of a disabled port is removed, the information displayed by this - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 643
10: -Area 11: -Area 12: -Area 13: -Area 14: -Area 15: -Area 16: id (sw) Vendor: AGILENT (output truncated) Serial No: H1149T2 Serial No: H112TUD Serial No: detailed SFP information for a Finisar "smart" SFP: switch:user> sfpshow 1/3 Identifier: 3 Manual Publication Number: 53-1000240-01 2-609 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 644
case is for readability. sfpShow To display detailed information for GbE port 0 on a Silkworm 7500: switch:admin> sfpshow ge0 Identifier: 3 SFP Connector: 7 LC Transceiver: Serial No: A00143427 Date Code: 020511 2-610 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 645
case is for readability. sfpShow 2 To display all SFP information: switch:user> sfpshow -all Port 0: Identifier: 3 SFP Connector: 7 LC Transceiver: 050c402000000000 100, output truncated) See Also switchShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-611 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 646
ports. Synopsis shellflowcontroldisable Description Use this command to disable XON/XOFF flow control on the console serial ports. Flow control is disabled by default . Because this command changes the flow control on the console serial port : switch:admin - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 647
console serial port. Synopsis shellflowcontrolenable default. Because this command changes the flow control on the console serial port from the console serial port. This command cannot an extended period of time, the switch might reboot. It is recommended to flow control: switch:admin> - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 648
. This command is not supported on this platform as of FOS 5.1 - use slotPowerOff. Note The execution of this command is subject to Admin Domain restrictions that may be in place. See Also slotShow, slotPowerOff, bladeDisable 2-614 Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 649
. This command is not supported on this platform as of FOS 5.1 - use slotPowerOn. Note The execution of this command is subject to Admin Domain restrictions that may be in place. See Also slotShow, slotPowerOn, bladeEnable Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 650
operand: slotnumber Specify the slot number of the blade to be powered down. This operand is required. To power off blade unit 3: switch:admin> slotpoweroff 3 Slot 3 is being powered off See Also powerOffListSet, powerOffListShow, slotPowerOn, slotShow 2-616 Fabric OS Command Reference - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 651
following operand: slotnumber Specify the slot number of the blade to be powered on. This operand is required. To power on blade unit 3: switch:admin> slotpoweron 3 Powering on slot 3. See Also slotPowerOff slotShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-617 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 652
type 1 CP1 control processor blade 2 FC-16 port blade 4 FC2-16 port blade 5 CP2 control processor blade 16 CP4 control processor blade 17 FC4-16 port blade 18 FC4-32 port blade 24 FR4-18i port blade 31 FR4-16IP port blade 36 FR4-48 port blade Status Displays the status of the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 653
all slots in the system: switch:user> slotshow Slot Blade Type ID Status 1 SW BLADE 2 FAULTY 2 SW BLADE 2 DISABLED 3 SW BLADE 2 ENABLED 4 SW BLADE 2 DIAG RUNNING POST2 5 CP BLADE 1 ENABLED (User Ports Disabled) 6 CP BLADE 1 ENABLED 7 AP BLADE 24 LOADING 8 SW BLADE 2 DIAG - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 654
the switch by sending SERDES BIST patterns from port N's transmitter, and looping the patterns back into the same port N's port speeds to 2 GBit/sec 3 Sets and locks all port speeds to 3 GBit/sec 4 Sets and locks all port speeds to 4 GBit/sec (default) 2-620 Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 655
Specifies the number of test repetitions. By default, the test runs once. Refer to itemList for further details. To test the serial link of the following port path: switch:admin> sltest -ports 0/5-0/31 -speed 4 -lb_mode 1 passcnt 1 Running Port sltest .... passed. Diagnostic See Also When it - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 656
default switch. The configuration includes SNMPv1 and SNMPv3 configuration, access control list (ACL), MIB capability, and system group. It supports set, reset to default current switch. Note level supported by to 16 characters. The default values trap recipients. By default, this value is set - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 657
of three entries of role snmpadmin and three entries of role snmpuser are supported. Separate default passwords are provided for creation of authKey and privKey for each entry. Default set of passwords are published and default algorithm (MD5/SHA) is used to create initial set of auth keys. You - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 658
64 switch. The default value is 'yes'. Users can also turn on or off individual FICON Traps. The individual FICON Traps are linkRNIDDeviceRegistration, linkRNIDDeviceDeRegistration, linkLIRRListenerAdded, linkLIRRListenerRemoved and linkRLIRFailureIncident. 2-624 Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 659
receive HA traps from the switch. The default value is 'yes'. Users default value is set as Fibre Channel Switch. The location of the system (switch). The default value is set as End User Premise. The contact information for this system (switch). The default value is set as Field Support and password, - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 660
IP address in dot notation: [0.0.0.0] 10.32.225.1 Trap recipient Severity level : (0..5) default ***** sysDescr = Fibre Channel Switch sysLocation = End User Premise sysContact = Field Support authTraps = 0 (OFF) ***** Are you sure? (yes, y, no, n): [no] y 2-626 Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 661
mixed case is for readability. snmpConfig 2 To change the SNMPv3 configuration: switch:admin> snmpconfig --set snmpv3 SNMPv3 user configuration: User (rw): [snmpadmin1] notation: [0.0.0.0] Committing configuration...done. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-627 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 662
f): [true] Access host subnet area in dot notation: [0.0.0.0] 10.32.148.0 Read/Write? (true, t, false, f): [true] f ] Committing configuration...done. To display the mibCapability configuration: switch:admin> snmpconfig --show mibCapability FE-MIB: YES SW- Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 663
manager. The default value is yes. SW-TRAP Specifying yes means the SNMP management application can receive SWTRAPS from the switch. The default value is yes on the desired traps individually. See the Fabric OS MIB Reference Manual for more information. Note The execution of this command is - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 664
for configuring SNMP MIB traps: switch:admin> snmpmibcapset The SNMP Mib/Trap Capability has been set to support FE-MIB SW-MIB FA-MIB yes] fruHistoryTrap (yes, y, no, n): [no] See Also agtCfgDefault, agtCfgSet, agtCfgShow 2-630 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 665
default value is yes. FICON-MIB Specifying yes means the user can access FICON-MIB variables with an SNMP manager. The default default value is yes. SW-TRAP Specifying yes means the SNMP management application can receive SWTRAPS from the switch. The default switch. The default switch. The default - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 666
snmpMibCapShow Note agtCfgDefault also resets the SNMP MIB and trap capability to default along with other SNMP Examples none To display the options for configuring the SNMP MIB capability: switch:admin> snmpmibcapshow FE-MIB: YES SW-MIB: YES FA-MIB: YES Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 667
itemlist Specify a list of user ports to test. By default, all of the ISL ports in the current switch will be tested. Refer to itemList help pages for further details. -setfail mode Instruct spinFab how to mark failed ports. If set to 1, it will mark failing ports as FAILED. If set to 0, it will - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 668
default. To test cascading ISL links: switch:admin> spinfab -ports 1/0 - 1/2 spinfab running... spinfab: Completed 11 megs, status: passed. port 0 test status: 0x00000000 -- passed. port 1 test status: 0x00000000 -- passed. port Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 669
to spinSilk. Note The command is supported only on SilkWorm 200E, 3250, default). For -lb_mode set to 0 or 1, the following speed modes are available to test the speed negotiation. 3 Set all even ports' speed for autonegotiate. Set all odd ports' speed for 1 Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 670
ports' speed for 2 Gbit/ sec. Specifies a list of user ports to test. By default, all the user ports in the specified slot (--slot) will be used. Refer to itemList for further details. To measure line-speed jitter: switch:admin> spinjitter -ports OS Command Reference Manual Publication Number: 53- - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 671
the Fabric OS Message Reference for more information. See Also backport, camTest, centralMemoryTest, cmemRetentionTest, cmiTest, crossPortTest, itemList, portLoopbackTest, portRegTest, spinSilk, sramRetentionTest Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-637 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 672
loopback modes 0 (cable) or 1 (loopback plug, default) are selected, you must have the appropriate termination on all tested ports. If not, the ports without the correct termination do not achieve synchronization and the test fails. The command is supported only on SilkWorm 200E, 3250, 3850, 3900 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 673
of the switch are faulty. port. The test result might display that more frames have been transmitted on some ports, but not less. The default Port loopback (loopback plugs) 2 External (SERDES) loopback 3 Silkscreen loopback 5 Internal (parallel) loopback Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 674
, where it controls the speed at which each port is operated. For 1 Gbit/sec-only products, ports' speed to 2 Gbit/sec; set all odd ports' speed to 1 Gbit/ sec. 8,6 Set all even ports' speed to 1 Gbit/sec; set all odd ports user ports to test. By default, all of the user ports in the current switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 675
functional test on selected ports: switch:admin> spinsilk -ports 1/0 - 1/2 Running Spin Silk One moment please ...Ports Segmented (0) switchName: switch switchType: 10.1 switchState PORT_WRONG RXQ_FRAME_ERR Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-641 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 676
Fabric OS Message Reference for more information. See Also backport, camTest, centralMemoryTest, cmemRetentionTest, cmiTest, crossPortTest, itemList, portLoopbackTest, portRegTest, spinJitter, sramRetentionTest 2-642 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 677
on an operational switch. You must first disable the switch using the switchDisable command. The command is supported only on SilkWorm 200E execute this test. The default value is 1. -ports itemlist Specify a list of blade ports to test. By default, all the blade ports in the specified slot - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 678
case is for readability. sramRetentionTest Examples To run a data retention test: switch:admin> sramretentiontest 2 Running SRAM Retention Test ... passed. Diagnostics Following are , itemList, portLoopbackTest, spinSilk 2-644 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 679
in bports clears; otherwise, the user ports specified in -uports clears. The default value is 0. To clear port and diagnostic statistics: switch:admin> statsclear -bports 1/10-1/62 -use_bports 1 See Also itemList Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-645 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 680
: -passcnt count Specify the number of times to perform this test. The default value is 1. This operand is optional. -ports itemlist Specify a list of user ports to run the test. If omitted, all the user ports in the switch are assumed. Refer to itemList for more information about selecting - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 681
-STSRCV DIAG-STSFRMCNT DIAG-STSWRDCNT DIAG-STSALPACNT Refer to the Fabric OS Message Reference for more information. See Also camTest, itemList Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-647 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 682
Admin Domain restrictions that may be in place. Operands Examples This command has the following operand: -ports itemlist Specify a list of user ports to test. By default, all the user ports in the switch are tested. Refer to itemList help pages for further details. To stop the portTest command - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 683
even when a message with FFDC attributes is logged. FFDC is enabled by default. Note The execution of this command is subject to Admin Domain restrictions that the command syntax is displayed. To display the FFDC configuration: switch:admin> supportffdc --show First Failure Data Capture (FFDC) is - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 684
password][-d remotedirectory] supportftp -t hours supportftp -R Description Use this command to set, clear, or display support FTP parameters, or a time interval to check the FTP server. Note If there is no parameter specified, this command defaults Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 685
-s -h 192.168.67.126 -u anonymous -d tracedump supportftp: ftp parameters changed. To display a time interval to check the FTP server: switch:admin> supportftp -t 24 supportftp: ftp check period changed. See Also supportSave, supportShow, traceDump, traceFtp, traceTrig Fabric OS Command Reference - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 686
is issued. If there are BP blades installed on the switch, it also retrieves a support file (as a .tar.gz file) from each slot. is optional; if omitted, anonymous FTP is used. Specifies the password for the FTP server. This operand is optional; if omitted, Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 687
/routing1-S6-200508280208-CHKRPM.ss: 10.04 kB 694.31 B/s Saving support information for switch:routing1, module:DIAGLOG... ...rtSave_files/routing1-S6-200508280207-DIAGLOG.ss: 195.34 kB (output truncated) 64.62 kB/s Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-653 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 688
Password: ***** Remote Directory: tmp Saving support information for switch: support information for switch:swd76, module:Zone_Log... /tmp/supportSave_files/swd76-S6-200508280207-Zone_Log.ss: 48.16 kB 16.02 kB/s Saving support information for switch Saving support information for switch:routing1 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 689
diagShow (per-slot) • portShow (per-port) • portLoginShow (per-port) • portRegTest (per-port) • portRouteShow (per-port) • portCamShow (per-port) • portLogDump (per-port) • fabric (ENABLED by default) • fabricShow • islShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-655 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 690
uRouteShow • services (ENABLED by default) • fdmiCacheShow • fdmiShow • nsShow • nsAllShow • nscamShow • nscamShow -t • ns portshow • security (ENABLED by default) • authUtil • authUtil -dump -a • secFabricShow • secGlobalShow • secModeShow 2-656 Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 691
ENABLED by default) • bootenv • sin • df • ifconfig • route • hostname • portlog (ENABLED by default) • portLogDump • system (ENABLED by default) • -d576 • emtraceshow • emtraceshow2 • emhsmtraceshow • systraceshow -d Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-657 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 692
• timeout • historyShow • portSwapShow • configShow • extend (DISABLED by default) • buffers (per-port) • credits (per-port) • data (per-port) • phantom (per-port) • properties (per-port) • statistics (per-port) • filter (DISABLED by default; this group has lengthy output) • filterportshow (per - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 693
Note: Enter commands in lowercase only; mixed case is for readability. supportShow 2 • fcrResourceShow • FCIP (DISABLED by default) • portShow fciptunnel ge$k all • portShow fciptunnel $1/ge$k all Note The execution of this command is subject to Admin Domain restrictions that may be in place. - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 694
Examples This command has the following operands: slotnumber/portnumber1-portnumber2 Specify the range of ports to display. If the slotnumber/portnumber parameter is omitted, all ports in the switch display in the per-port outputs. The slotnumber must be provided when specifying a range of - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 695
Synopsis supportshowcfgdisable [os | exception | port | fabric | services | security | network | portlog port Disables the port group commands fabric Disables the fabric group commands services Disables the service under the supportShow command: switch:admin> supportshowcfgdisable os Config - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 696
Synopsis supportshowcfgenable [os | exception | port | fabric | services | security | network | portlog port Enables the port group commands fabric Enables the fabric group commands services Enables the service under the supportShow command: switch:admin> supportshowcfgenable os Config - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 697
To display which groups of commands are enabled in the supportShow command: switch:admin> supportshowcfgshow os enabled exception enabled port enabled fabric enabled services enabled security enabled network enabled portlog enabled system enabled extend disabled filter disabled - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 698
switchbeacon [mode] Description Use this command to enable or disable switch beaconing mode. When beaconing mode is turned on, the port LEDs flash amber, left to right and right to left, from port 0 to the highest port number and back to port 0. The beaconing mode continues until you turn it off - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 699
. Synopsis switchcfgpersistentdisable Description Use this command to persistently disable the switch. All Fibre Channel ports are taken offline. If the switch was part of a fabric, the remaining switches reconfigure. The switch remains disabled even after a reboot. The disable process can be - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 700
only; mixed case is for readability. switchCfgPersistentEnable switchCfgPersistentEnable Enables a switch persistently. Synopsis switchcfgpersistentenable Description Use this command to persistently enable the switch. All Fibre Channel ports which did not fail power-on self-test (POST) are - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 701
fixed at 2 Gbit/sec. 4 4-Gbit/sec mode. The port is fixed at 4 Gbit/sec. To set the speed level for all ports on a switch: switch:admin> switchcfgspeed 0 Committing configuration...done. See Also portCfgSpeed, portShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-667 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 702
. Synopsis switchcfgtrunk mode Description Use this command to enable or disable trunking on all the ports of a switch. Note This command requires the Brocade ISL Trunking license. You can disable or enable trunking using the portCfgTrunkPort or switchCfgTrunk commands. When the command is executed - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 703
running many of the diagnostic tests. All commands that require the switch to be disabled send an error if invoked while the switch is enabled. The switch does not need to be disabled before rebooting or powering off. As each port is disabled, the front panel LED changes to a slow flashing yellow - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 704
Enables the switch. Synopsis switchenable Description Use this command to enable the switch. All Fibre Channel ports that passed switch: switch:admin> switchenable See Also switchCfgPersistentDisable, switchCfgPersistentEnable, switchDisable, switchShow 2-670 Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 705
switch name. All switches have a symbolic name that is primarily used for switch management. This name is shown in the Fabric OS CLI prompt, under each switch switch name. Enter this command with no operand to display the current switch name. Changing the switch name for the switch. name can include - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 706
switch without disrupting the other switch in a dual-switch chassis. This command is equal to running switchShutdown and switchStart. Note This command is not supported modules...Done. Initializing kernel modules...Done. Starting all switch daemons...Done. Powering on slot 1...Done. Powering on - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 707
off) FC Router BB Fabric ID The backbone fabric ID for FC routing. The switch summary is followed by one-line description for non-EX_Ports and one or two lines for EX_Ports: Area Part of the 24-bit port ID, which consists of domain, area number, and optional AL_PA. Area column is only - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 708
receiving light but out of sync. In_Sync Module receiving light and in sync. Laser_Flt Module signaling a laser fault. Port_Flt Port marked faulty. Diag_Flt Port failed diagnostics. Lock_Ref Locking to the reference signal. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 709
Protocol support by GbE port. ISCSI Ports support ISCSI. FCIP Ports support FCIP. The comment field is blank, or displays: Disabled Port is disabled. Bypassed Port is bypassed (loop only). Loopback Port is in loopback mode. E_Port Fabric port; displays WWN and name of attached switch. If the port is - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 710
with GbE ports in a switch. To display the port count: switch:admin> switchshow -portcount ports= 64 To display the port status for :1c"san130" (output truncated) E-Port E-Port E-Port E-Port E-Port E-Port E-Port E-Port 2-676 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 711
in lowercase only; mixed case is for readability. switchShow 2 To display GE ports with iSCSI sessions: san116:user> switchshow -iscsi Ports of Slot 1 ge0 ge1 ge2 ge3 ge4 ge5 ge6 ge7 Sessions 0 0 0 0 0 0 0 0 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-677 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 712
is for readability. switchShow To display switch information: top_4a3_a10:root> switchshow switchName: top_4a3_a10 Port 10:00:00:00:00:04:00:00 95 8 15 035f00 id N2 Online F-Port 10:00:00:00:00:02:00:00 208 8 16 03d000 -- -- Offline [output truncated] 216 8 24 03d800 -- -- Online VE-Port - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 713
Note: Enter commands in lowercase only; mixed case is for readability. switchShutdown 2 switchShutdown Not supported on this platform. Synopsis switchshutdown Description This command is not supported on this platform as of FOS 5.1. Note The execution of this command is subject to Admin Domain - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 714
2 Note: Enter commands in lowercase only; mixed case is for readability. switchStart switchStart Not supported on this platform as of Fabric OS 5.1. 2-680 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 715
example, assuming that the switch contributor values are set to the default values, if there is one faulty port in a switch, then this contributor would set the overall switch status to MARGINAL. If two ports were faulty, then this contributor would set the overall switch status to DOWN. Note The - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 716
is (0..0), the policy parameter is NOT applicable ** to the switch. Simply hit the Return key. The minimum number of Bad 64) [2] MarginalPorts contributing to MARGINAL status: (0..64) [1] (output truncated) See Also switchStatusPolicyShow, switchStatusShow 2-682 Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 717
DOWN parameter is set to 3, and three ports fail in the switch, then the status of the switch changes to DOWN. Note The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-683 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 718
switch status policy parameters: Down Marginal PowerSupplies 2 1 Temperatures 2 1 Fans 2 1 WWN 0 1 CP 0 1 Blade 0 1 Flash 0 1 MarginalPorts 2 1 FaultyPorts 2 1 MissingSFPs 0 0 See Also switchStatusPolicySet, switchStatusShow 2-684 Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 719
Watch license are able to view the list of unhealthy ports. This command displays the overall switch status, along with the status of each of the following switchStatusPolicyShow for details on the calculation of contributors and overall switch status. Note The execution of this command is subject - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 720
report: switch:user> switchstatusshow Switch Health Report Switch Name: switch IP address: 10.10.255.255 SwitchState: MARGINAL Duration: 00:06 Power supplies monitor Temperatures monitor Fans monitor WWN servers monitor Standby CP monitor Blades monitor Flash monitor Marginal ports monitor - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 721
is subject to Admin Domain restrictions that may be in place. Operands Examples none To view the uptime for the switch: switch:user> switchuptime 9:50pm up for 20 mins See Also switchReboot, switchShutdown, switchStart Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-687 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 722
forwarding messages to the servers added through the command syslogdIpAdd. The default facility is LOG_LOCAL7. Note The execution of this command is facility is displayed. To set the syslog facility to LOG_LOCAL1: switch:admin> syslogdfacility -l 1 Syslog facility changed to LOG_LOCAL1 See Also - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 723
are configured, the switch forwards all error log entries to the syslogd on the specified server(s). Up to six servers are supported. Note The execution of machines to which system messages are sent: switch:admin> syslogdipadd 192.168.1.60 See Also errShow, syslogdFacility, syslogdIpRemove, - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 724
server running syslogd. This operand is required. To remove the address 192.168.1.60 from the list of machines to which system messages are sent: switch:admin> syslogdipremove 192.168.1.60 See Also errShow, syslogdFacility, syslogdIpAdd, syslogdIpShow 2-690 Fabric OS Command Reference - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 725
of this command is subject to Admin Domain restrictions that may be in place. Operands Examples none To display all syslog daemon IP addresses: switch:admin> syslogdipshow syslog.IP.address.1: 192.168.1.60 syslog.IP.address.2: 192.168.1.88 syslog.IP.address.3: 192.168.2.77 See Also errShow - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 726
the active CP, standby CP, and any AP blades. After doing this, you need to manually power off the system. If you want to reboot the system, manually turn the power switch on. Note This command is not supported on the standby CP. Note The execution of this command is subject to Admin Domain - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 727
switch:admin> sysshutdown This command will shutdown the operating systems on your switch. You are required to power-cycle the switch : Switching to 16 05:47:20 2005... The system is going down for system halt NOW !! INIT: Switching switch:admin> sysshutdown Shut down the whole system is not support - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 728
. The burninErrShow displays the stored burn-in errlogs; the logs by blade are saved in /var/log/verify.slot files. On fixed-port-count products, the slot defaults to 0. The command monitors the testing and terminates the burn-in activity if all the elements fail. Each failing slot only outputs the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 729
in the fabric: switch:admin> systemverification -short systemverification: Setting parameters for short run. systemverification: burnin parameters. CURRENT - KEYWORD : DEFAULT 1 - number_of_runs : 1 2 - vib : 2 10 - thermal : 10 SYSTEMVERIFICATION - label : BURNIN 2 - min_lb_mode - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 730
), the sensor state, and the temperature. The temperature readings are given in both Centigrade and Fahrenheit. Refer to the hardware reference manual for your switch to determine the normal temperature range. Note The execution of this command is subject to Admin Domain restrictions that may be in - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 731
to disable login timeouts. This operand is optional; if omitted, the command displays the current timeout value. To set the idle timeout to 10 minutes: switch:admin> timeout 10 IDLE Timeout Changed to 10 minutes The modified IDLE Timeout will be in effect after NEXT login See Also none Fabric OS - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 732
local switch. • For each path cost, the associated output port on the local switch, the path cost, the number of hops from the local switch to the destination switch and a summary of all ports are domains in the fabric. 2-698 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 733
2 domains in the fabric; Local Domain ID: 1 Local Translate Domain 4 owned by port: 5 Local Translate Domain 8 owned by port: 4 Domain: 6 Metric: 500 Name: switch Path Count: 4 Hops: Out Port: In Ports: Total Bandwidth: Bandwidth Demand: Flags: 1 60 None 2.000 Gbps 0 % D Hops: Out - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 734
the switch. Note If there is no parameter specified, this command defaults to traceDump -S. The default remote file will be generated, one with .dmp for the main switch and one with .tar.gz for the embedded BP slot 5: switch:admin> tracedump -n -s 5 To remove a trace dump: switch:admin> tracedump - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 735
hostip][-u username][-p password][-d remotedirectory][-f remotefile] Description Use this command to display, enable, or disable trace auto-FTP or to retrieve a trace dump file from the switch to the FTP site immediately. Note If there is no parameter specified, this command defaults to traceFtp - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 736
mixed case is for readability. traceFtp Examples To retrieve a trace dump file: switch:admin> traceftp -n -h 192.168.67.126 -u anonymous -d tracedump -f dumpfile the auto-FTP feature: switch:admin> traceftp -e trace auto-FTP enabled To disable the auto-FTP feature: switch:admin> traceftp -d trace - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 737
is subject to Admin Domain restrictions that may be in place. Examples To display information on the track-changes commands: switch:admin> trackchangeshelp trackChangesSet Configure alert for login/logout/config update trackChangesShow Displays status of track changes See Also trackChangesSet - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 738
feature or 0 to disable the feature. The default (if no operand is specified) is to disable switch:admin> trackchangesshow Track changes status: ON Track changes generate SNMP-TRAP: YES See Also agtCfgSet, agtCfgShow, trackChangesHelp, trackChangesShow 2-704 Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 739
output from the track-changes feature is dumped to the error log for the switch. Use the errDump command or errShow command to view the error log. Note The none To display the status of the track-changes feature: switch:admin> trackchangesshow Track changes status: ON Track changes generate SNMP - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 740
. To debug a trunk connection: switch:admin> trunkdebug 43 44 Switch does not support trunking switch:admin> trunkdebug 62 63 port 62 and 63 are trunked together See Also portCfgTrunkPort, switchCfgTrunk, trunkShow 2-706 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 741
00:60:69:51:43:04 deskew 16 deskew 15 deskew 17 deskew 16 MASTER 3:24 -> 14 10:00:00:60:69:51:42:dd deskew 15 MASTER To display trunking information for a switch that is part of an FC Router backbone fabric interlinking Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-707 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 742
:1e:37:12:13 64-> 16 10:00:00:05:1e:37:12:13 65-> 19 10:00:00:05:1e:37:12:13 4 deskew 17 MASTER 4 deskew 16 4 deskew 16 4 deskew 16 4 deskew 17 4 deskew 17 4 deskew 15 4 deskew 16 switch:admin> switchshow 48 4 0 013000 id N4 Online EX-Port (Trunk port, master is Slot 4 Port 1 ) 49 4 1 013100 id - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 743
switch switch (when the security feature is enabled) connect to the NTP server and broadcast time service updates. All switches in the fabric maintain the current clock server IP address in flash memory. By default default. The NTP server used must support supports a full the switch. When - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 744
at the specified IP address and then verify that the new IP address was saved: switch:admin> tsclockserver LOCL switch:admin> tsclockserver "123.123.123.123" Updating Clock Server configuration...done. switch:admin> tsclockserver 123.123.123.123 See Also date 2-710 Fabric OS Command Reference - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 745
default. Time zone is used only in computing local time, which is used for error reporting and logging. An incorrect time zone setup does not affect the switch operation in any way. System services started during the switch individual switch. switches are housed in one chassis, the time zone of switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 746
mode: switch:admin> El Salvador 36) Peru 3) Argentina 20) French Guiana 37) Puerto Rico 4) Aruba 21) Greenland 38) St Kitts & Nevis 5) Bahamas 22) Grenada 39) St Lucia 6) Barbados 23) Guadeloupe 40) St Pierre 7) Belize 24 32) Netherlands Antilles 49) Virgin Islands (US) 16 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 747
Time - south Idaho & east Oregon 16) Mountain Time - Navajo 17) Mountain Standard Time - Arizona 18) Pacific Time 19) Alaska Time 20) Alaska Time - Alaska panhandle 21) Alaska Time - Alaska panhandle neck 22) Alaska Time - west Alaska 23) Aleutian Islands 24) Hawaii Enter number or control-D to - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 748
ports to test. By default, all the blade ports in the specified slot are tested. Refer to the itemList command help page for more information. To execute this test: switch:admin> turboramtest -passcnt 2 -ports 2-714 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 749
mini-switch. This is done by configuring all of the ports on the mini-switch in internal loopback and sending a frame from each quadrant to each other port on the same mini-switch seven frames use unique data type. Note This command is supported only on SilkWorm 200E,3250, 3850, 3900,4100, 24000, - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 750
number of frames has been transmitted on each port. The default value is 10, so the number of ports' speed for 2 Gbit/sec, set all odd ports' speed for 1 Gbit/ sec. 6,8 Set all even ports' speed for 1 Gbit/sec, set all odd ports' speed for 2 Gbit/ sec. 2-716 Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 751
default value is 0. Specify a list of user ports to test. By default, all of the user ports in the current switch are tested. This option can be used to restrict testing to the specified ports. To run the txdPath test: switch Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 752
is subject to Admin Domain restrictions that may be in place. Operands Examples none To display the length of time the system has been operational: switch:admin> uptime 12:03am up 4:56, 3 users, load average: 1.17, 1.08, 1.08 See Also date, fastboot, reboot 2-718 Fabric OS Command Reference - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 753
addressed to domain 2 to go through port 5: switch:admin> urouteconfig 1 2 5 done. switch:admin> urouteshow 1/1 2 Local Domain ID: 1 In Port Domain Out Port Metric Hops Flags Next (Dom, Port) 1 2 5 500 1 S 2,5 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-719 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 754
2 Note: Enter commands in lowercase only; mixed case is for readability. uRouteConfig See Also configShow, interfaceShow, uRouteRemove, uRouteShow 2-720 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 755
domain of the static route to remove. To remove a static route for all traffic coming in from port 1 and addressed to domain 2: switch:admin> urouteremove 1 2 done. See Also configShow, dlsShow, uRouteConfig, uRouteShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-721 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 756
is received. Except for the cases in which you perform a port swap or enable extended-edge PID (PID Format 2) on a switch, the value is equal to the Area field displayed by the switchShow command. Refer to Fabric OS Administrator's Guide for more information regarding the extended-edge PID format - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 757
11 to domain 4 only: switch:admin> urouteshow 1/11, 4 Local Domain ID: 3 In Port Domain Out Port Metric Hops Flags Next (Dom, Port) 11 4 16 500 1 D 4,16 See Also portRouteShow, topologyShow, uRouteConfig, uRouteRemove Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 758
default Admin, SwitchAdmin or User account. When the userConfig command completes, account information is saved persistently. In a platform supporting multiple switch domains, account information is saved only to the switch 2-724 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 759
This command also prompts for an initial password. There can be a maximum of 256 an existing account named username from the switch. This action does not take any account deletion: You cannot delete any default account. You cannot delete your own Manual Publication Number: 53-1000240-01 2-725 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 760
named username, on the switch. The -r option changes the option expires the current password, forcing a password change the next time Admin Domain of any default account. You cannot certain operations cause a switch to delete some switch-local user database only, regardless of whether the switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 761
Date: Not Applicable Locked: No AD membership: 0 Home AD: 0 To change account attributes: switch:admin> userconfig --change joe -e no Broadcast message from root Sat Apr 2 03:03:32 2005... Security Policy, Password or Account Attribute Change: joe will be logged out Attribute for account joe has - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 762
the admin-level login name to the Brocade-specific default of admin and the user-level login name to the Brocade-specific default of user before enabling security; otherwise, the switch is not allowed in the secure fabric. Note This command is not supported on all platforms. Note The execution of - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 763
firmware version information in a switch: switch: admin> version Kernel: 2.4.19 Fabric OS: v5.2.0v5.2.0_pit_060911_0600 Made on: Mon Sep 11 18:55:09 2006 Flash: Mon Sep 11 19:26:15 2006 BootProm: 4.5.3 See Also firmwareDownload, reboot Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 764
10:00:ff:ff:ff:80:02:3c The switch must be rebooted for the new WWN to take effect. Reboot now? (yes, y, no, n): [yes] y Rebooting switch 0 ... [system reboots] switch:root> wwn 10:00:ff:ff:ff:80:02:3c See Also switchShow 2-730 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 765
of the current zone enforcement table. The reason for not being in the current enforcement table could be one of the Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-731 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 766
This is the assumed default mode flag value if switch:admin> zone --copy AD0.backup_zn To copy backup_zn zone from the root zone database (AD0) to the current Admin Domain, with Admin Domain member list filtering: switch:admin> zone --copy -f AD0.backup_zn 2-732 Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 767
database in the persistent storage: switch:admin> zone --validate -m 1 To validate the zone object zone_test in the zone database in the current transaction buffer: switch:admin> zone --validate -m 0 zone_test See Also zoneHelp Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 768
marks are required. Valid values can be one or more of the following: • A switch domain and port area number pair; for example, "2, 20". View the area numbers for ports using the switchShow command. • Node or port WWN. • QuickLoop AL_PA. • Zone alias name. To add aliases for three disk - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 769
numbers "s,p" where "s" is the switch number (domain ID) and "p" is the port area number. For example, "2, 20" specifies port area number 20 on switch domain 2. When a zone member is specified by port area number, all devices connected to that port are in the zone. If this port is an arbitrated loop - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 770
. Zone names are limited to 64 characters. "member" List of members to be included in zone, in quotation marks, separated by semicolons. Quotation marks are required. Can be one or more of the following: • A switch domain and port area number pair: for example, "2, 20". View the area numbers for - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 771
a Brocade Advanced Zoning license. When secure mode is enabled, this command can be issued only from the primary FCS switch. zone "Blue_zone": switch:admin> zonedelete "Blue_zone" See Also zoneAdd, zoneCreate, zoneRemove, zoneShow Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 772
that may be in place. Operands Examples none To display zone command help information: switch:admin> zonehelp aliAdd aliCreate aliDelete aliRemove aliShow Add a member to a zone alias Create transaction See Also none 2-738 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 773
for more information on name and member specifications. Note This command requires a Brocade Advanced Zoning license. When secure mode is enabled, this command can be issued only from the primary FCS switch. Operands Examples This command has the following operands: "objectName" The name of - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 774
configuration must be enabled using the cfgEnable command. Note This command requires a Brocade Advanced Zoning license. When secure mode is enabled, this command can be issued only from the primary FCS switch. Operands Examples This command has the following operand: "objectName" The name of - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 775
for more information on name and member specifications. Note This command requires a Brocade Advanced Zoning license. When secure mode is enabled, this command can be issued only from the primary FCS switch. Operands Examples This command has the following operands: "objectName" The name of - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 776
a Brocade Advanced Zoning license. When secure mode is enabled, this command can be issued only from the primary FCS switch. more of the following: • A switch domain and port area number pair: for example, enter "2,20" to view the area numbers for ports using the switchShow command. • World - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 777
This command requires a Brocade Advanced Zoning license. When secure mode is enabled, this command can be issued on any FCS switch in the fabric. memory. The default value is 0. This operand is optional. To display all zones beginning with the letters "A" through "C": switch:admin> zoneshow - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 778
2 Note: Enter commands in lowercase only; mixed case is for readability. zoneShow 2-744 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 779
to the Fabric OS Administrator's Guide. Advanced Zoning Commands The following commands are available with the purchase of a Brocade Advanced Zoning license key. Deletes a zone. zoneRemove Removes a member from a zone. Fabric OS Command Reference Manual 3-1 Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 780
transaction. defZone Activates or deactivates a default zone configuration, or displays the current commands are available with the purchase of a Brocade Advanced Zoning license. Table 3-2 QuickLoop Fabric Assist . 3-2 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 781
Command The following command is available with the purchase of a Brocade Extended Fabrics license key. Table 3-3 Extended Fabrics Commands Command Description portCfgLongDistance Configures a port to support long-distance links. Fabric Watch Commands The following commands are available - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 782
information about trunking refer to the Fabric OS Administrator's Guide. Table 3-5 Brocade Trunking Commands Command Description portCfgTrunkPort Configures a port for trunking. switchCfgTrunk Configures a switch for trunking. trunkDebug Debugs a trunk link failure. Advanced Performance - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 783
for end-to-end (EE) monitors. Displays the AL_PA CRC count by port or by AL_PA. Displays user-defined end-to-end monitors on a port. Displays filter-based monitors for a port. Displays the current end-to-end mask of a port. Fabric OS Command Reference Manual 3-5 Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 784
Guide. Table 3-7 Brocade in the switch. Displays the size switch to take over as primary FCS switch Sets the admin password for non-FCS switches. Aborts all defined policy set to all switches in the fabric. Adds all switches in the fabric. Displays an existing security policy. Resets security - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 785
3 Table 3-7 Brocade Secure Fabric OS Commands (Continued) Command Description secTempPasswdReset Resets a password on a remote switch. secTempPasswdSet secTransAbort secVersionReset Sets a temporary password on a remote switch. Aborts current security transaction. Resets the version stamp to - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 786
3 3-8 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 787
run from the primary FCS switch. cfgSave Must be run from the primary FCS switch. cfgShow Can be run on all FCS switches. cfgSize Must be run from the primary FCS switch. cfgTransAbort Must be run from the primary FCS switch. Fabric OS Command Reference Manual 4-1 Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 788
secPolicyRemove Must be run from the primary FCS switch. secPolicySave Must be run from the primary FCS switch. secPolicyShow Can be run on all FCS switches. secTempPasswdReset Must be run from the primary FCS switch. 4-2 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 789
Must be run from the primary FCS switch. zoneObjectExpunge Must be run from the primary FCS switch. zoneObjectRename Must be run from the primary FCS switch. zoneRemove Must be run from the primary FCS switch. Fabric OS Command Reference Manual 4-3 Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 790
4 4-4 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 791
to nonvolatile memory. firmwareDownload Downloads firmware onto switch. firmwareDownloadStatus Displays the progress and status of a firmware download. firmwareRestore Restores the old firmware in the switch. firmwareShow Displays firmware versions in the switch. h Displays shell history - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 792
supportSave Saves support information for RASLOG, TRACE, and supportShow. switchName Displays this switch's name. tsClockServer Displays time zone. upTime Displays how long switch has been up. version Displays firmware version. 5-2 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 793
on page 6-4 supportShow Control Commands The supportShow command is used to display support information by executing groups of preselected Fabric OS and Linux commands. The commands from displaying under supportShow. Fabric OS Command Reference Manual 6-1 Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 794
proc entries. exception faultshow traceshow errDump errDump -a/-p port portShow diagShow portregshow portShow portstructshow portloginshow bloomdatashow portregshow cfgShow rcssmshow rcsinfoshow rcsregistryshow 6-2 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 795
) Command Group Fabric OS v3.2.0 Fabric OS v4.x/v5.x services nsShow nsAllShow nscamShow fdmiCacheShow ficonDbg dump rnid ficonDbg log ficonShow ilir portlog portLogDump (no parameters) portLogDump portLogDump 0, 1 Fabric OS Command Reference Manual 6-3 Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 796
ptbufshow ptcreditshow ptDataShow ptPhantomShow ptPropShow ptStatsShow filter filtershow filterportshow perfmon ps_dump ps_dump -a -n port# Note Many of the commands executed by supportShow are intended for support use only. These commands are not intended for end-users. Proc Entry - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 797
: 1.69 (pvr 4011 0145) bogomips : 199.47 machine : Brocade Silkworm plb bus clock : 100MHz pci bus clock : 33MHz /proc/devices vcs 10 misc 89 i2c 90 mtd 128 ptm 136 pts 162 raw 245 swd 246 ham 247 fc 248 fc-switch 249 fabsys 250 fss_kt 251 fss_data 252 Manual Publication Number: 53-1000240-01 6 6-5 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 798
proc rw 0 0 none /dev/pts devpts rw 0 0 none /tmp ramfs rw 0 0 /dev/hda2 /mnt xfs rw,noatime 0 0 /diag /diag dfs rw 0 0 6-6 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 799
32 1 1 1 ip_dst_cache 65 168 160 7 7 1 arp_cache 2 30 128 1 1 1 blkdev_requests 128 160 96 4 4 1 xfs_chashlist 193 404 16 2 2 1 xfs_ili 2004 5668 152 135 218 1 xfs_ifork 0 0 56 0 0 1 xfs_efi_item 0 12 328 0 1 1 xfs_efd_item 0 12 328 0 1 1 ---- Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 800
/proc/tty/drivers serial /dev/cua 5 64-65 serial:callout serial /dev/ttyS 4 64-65 serial pty_slave /dev/pts 136 0-255 pty:slave pty_master /dev/ptm 128 0-255 pty:master pty_slave /dev/ttyp 3 #1 Wed Mar 26 00:04:35 PST 2003 6-8 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 801
-specific: checks such as whether the command is supported on the platform for which it is targeted, = none/not available) Command Name User Oper Switch Zone Fabric Basic Admin ator Admin Admin Admin Switch Admin authUtil NN N N N N OM aaaConfig Manual A-1 Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 802
= observe-modify, N = none/not available) Command Name User Oper Switch Zone Fabric Basic Admin ator Admin Admin Admin Switch Admin aptPolicy NN N N N N N auditCfg OO O O O O OM chassisName O OM OM N OM O OM Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 803
-modify, N = none/not available) Command Name User Oper Switch Zone Fabric Basic Admin ator Admin Admin Admin Switch Admin chassisShow O OM OM N OM O OM chipRegShow O OM N OM O OM distribute NN N N OM N OM Fabric OS Command Reference Manual A-3 Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 804
OM = observe-modify, N = none/not available) Command Name User Oper Switch Zone Fabric Basic Admin ator Admin Admin Admin Switch Admin dlsReset OO O N OM O OM dlsSet OO O N OM O OM fazoneShow OO O OM OM O OM Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 805
modify, N = none/not available) Command Name User Oper Switch Zone Fabric Basic Admin ator Admin Admin Admin Switch Admin fcipChipTest O OM OM N OM O OM fciphelp OO OM OM N OM O OM ficonHelp OO O O O O O Fabric OS Command Reference Manual A-5 Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 806
observe-modify, N = none/not available) Command Name User Oper Switch Zone Fabric Basic Admin ator Admin Admin Admin Switch Admin ficonShow O OM OM N OM O OM filterTest O OM OM OM O OM haEnable O O OM N OM O OM Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 807
observe-modify, N = none/not available) Command Name User Oper Switch Zone Fabric Basic Admin ator Admin Admin Admin Switch Admin haFailover O O OM N OM O OM haShow O O O O O licenseIdShow O OM OM O OM O OM Fabric OS Command Reference Manual A-7 Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 808
, N = none/not available) Command Name User Oper Switch Zone Fabric Basic Admin ator Admin Admin Admin Switch Admin licenseport O OM OM N OM OM OM licenseRemove O OM O OM O OM nsZoneMember O O OM O OM O OM Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 809
N = none/not available) Command Name User Oper Switch Zone Fabric Basic Admin ator Admin Admin Admin Switch Admin openSource O OM OM O OM O OM passwd OM pkiCreate OO O N O O OM pkiRemove OO O N O O OM Fabric OS Command Reference Manual A-9 Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 810
observe-modify, N = none/not available) Command Name User Oper Switch Zone Fabric Basic Admin ator Admin Admin Admin Switch Admin pkiShow OO O N O O OM policy O OM OM OM O OM portLogDumpPort O OM OM O OM O OM Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 811
-modify, N = none/not available) Command Name User Oper Switch Zone Fabric Basic Admin ator Admin Admin Admin Switch Admin portLogEnable O OM OM O OM O OM portLogEventShow O OM OM psShow O OM OM N OM O OM Fabric OS Command Reference Manual Publication Number: 53-1000240-01 A-11 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 812
-modify, N = none/not available) Command Name User Oper Switch Zone Fabric Basic Admin ator Admin Admin Admin Switch Admin quietMode O OM OM N OM OM OM reboot O OM N OM O OM secTempPasswdReset ON O N OM O OM Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 813
, N = none/not available) Command Name User Oper Switch Zone Fabric Basic Admin ator Admin Admin Admin Switch Admin secTempPasswdSet ON O N OM O OM secTransAbort ON OM O OM supportShow O OM OM O OM O OM Fabric OS Command Reference Manual Publication Number: 53-1000240-01 A-13 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 814
N = none/not available) Command Name User Oper Switch Zone Fabric Basic Admin ator Admin Admin Admin Switch Admin supportShowCfgDisable O OM OM O OM O OM O OM O OM trunkDebug O OM OM N OM OM OM Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 815
= observe-modify, N = none/not available) Command Name User Oper Switch Zone Fabric Basic Admin ator Admin Admin Admin Switch Admin trunkShow O OM OM N OM OM OM tsClockServer O OM OM zoneShow OO O OM OM O OM Fabric OS Command Reference Manual Publication Number: 53-1000240-01 A-15 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 816
A A-16 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 817
services 2-16, 2-19, 2-22, 2-30, 2-32, 2-33, 2-35, 2-37, 2-39, 2-40, 2-41, 2-42, 2-43, 2-44, 2-46, 2-50, 2-52, 2-73, 2-76, 2-79, 2-80, 2-82, 2-84, 2-87, 2-90, 2-94, 2-96, 2-109, 2-117, 2-120, 2-121, 2-124, 2-125, 2126, 2-127, 2-128 215, 2-216, 2-217, 2-222, 2-225, 2-227, 2-229, 2-232 63, 2-64, 2-65, - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 818
716 Broadcom PHY transceiver 2-282 Brocade Security 2-550 buffer usage 2-430 burn-in 2-38, 2-46, 2-47, 2-48, 2-49, 2-126, 2-128, 2-129, 2-132, 2- 2-190 domain name service 2-140 dual-domain systems 2-16, 2-19, 2-75, 2-228, 2-297, Index-2 Fabric OS Command Reference Manual Publication Number: 53- - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 819
673 FC2-16 port blade 2-450, 2-452, 2-618 FC4-16 port blade 2-450, 2-618 FC4-32 port blade 2-450 Service 2-182, 2-236, 2- 495, 2-533 Fibre Channel Protocol 2-188, 2-189 FICON 2-109, 2-215 2408, 2-412 firmware download 2-227, 2-228, 2-232, 2-233 firmware Manual Publication Number: 53-1000240-01 Index-3 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 820
, 2-698, 2-722 FTP 2-86, 2-88, 2-93, 2-94, 2-228, 2-230, 2-231, 2545, 2-546, 2-547, 2-548, 2-554, 2-650, 2-651, 2-317, 2-364, 2-369, 2-372 ISL Inter-Switch Link 2-410 ISL Trunking 2-463, 2-668 ISL 64, 2-65, 2-68, 2-70, 2-71, 2-84, 2-112, 2-114, Index-4 Fabric OS Command Reference Manual Publication Number: - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 821
16, 2-17, 2-18, 2-19, 2-20, 2-21, 2-22, 2-23, 2-24, port type 2-220, 2-221, 2-222, 2-224, 2-430, 2-475, 2-512, 2-533, 2-535 portswap feature 2-530, 2-531, 2-532 POST 2-44, 2-48, 2-52, 2-107, 2-119, 2-120, 2-127, 2-128, 2-129, 2-133, 2-170, 2-600, 2-618, 2666, 2-670 Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 822
20, 2-23, 2-25, 2-26, 2-27, 2-28, 2-29, 2-57, 2-58, 2-59, 2-60, 2-61, 2-62, 2-63, 2-64 2- 123, 2-125, 2-127, 2-128, 2-129, 2-130, 2-132, secure mode 2-17, 2-20, 2-23, 2-25, 2- 20, 2-23, 2-33, 2-39, 2-56, 2-57, 258, 2-59, 2-60, 2-61, 2-62, 2-63, 2-64 2-635, 2-639, 2-716 serial port 2-150, 2-321, 2-331, - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 823
638, 2-643, 2-676, 2-715 SilkWorm 4900 switch 2-167, 2-168, 2-450, 2-620 SilkWorm 7500 switch 2-177, 2-179, 2-190, 2-197 SilkWorm Multiprotocol Router Model AP7420 2-208 single-domain systems 2-74, 2-672 SNMP 2-16, 2-17, 2-18, 2-19, 2-20, 2-21, 2-22, 223, 2-24, 2-72, 2-74, 2-84, 2-102, 2-471, 2-472 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 824
2-25, 2-26, 2-27, 2-28, 2-56, 2-57, 2-58, 259, 2-60, 2-61, 2-62, 2-63, 2-64, 2-65, 2-68, 270, 2-71, 2-72, 2-74, 2-84, 2-87, 2-100, 2-112, 2-113, 2-114, 739, 2-740, 2-741, 2-742, 2-743, 3-1, 32 Advanced Zoning commands 3-1 Index-8 Fabric OS Command Reference Manual Publication Number: 53-1000240-01
Publication Number: 53-1000240-01
Publication Date:
09/29/2006
Fabric OS
Command Reference Manual
Supporting Fabric OS v5.2.0