HP StorageWorks 4/8 Brocade Fabric OS Message Reference guide v6.2.0 (53-10011
HP StorageWorks 4/8 - SAN Switch Manual
View all HP StorageWorks 4/8 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks 4/8 manual content summary:
- HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 1
53-1001157-01 24 November 2008 Fabric OS Message Reference Supporting Fabric OS v6.2.0 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 2
applicable to the open source software, and obtain a copy of the programming source code, please visit http://www.brocade.com/support/oscd. Brocade Communications Systems, Incorporated Corporate Headquarters Brocade Communications Systems, Inc. 1745 Technology Drive San Jose, CA 95110 Tel: 1-408 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 3
ZONE January 2006 Reference Manual messages Fabric OS System Error Message 53-1000046-02 Minor updates to a few messages. Reference Manual June 2006 Fabric OS chapters. -Update throughout: rebranding, supported hardware, CLI changes. June 2007 Fabric OS Message Reference iii 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 4
added new messages to AG -Added new chapters: CNM, CTAP, CVLC, CVLM, KAC, RKD, SPC, SPM -Added new Audit chapters: AG, FCIP, FICU, IPAD, PORT, SWCH, UCST -Updated Introductory chapters. Aug 2008 53-1001157-01 Updated for Fabric OS v6.2.0: -Revised and added new messages to FSS, KSWD, CTAP, CNM - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 5
chapter xlvii How this document is organized xlvii Supported hardware and software xlvii What's new in this document xlviii Document 1 Event Auditing 2 System Logging Daemon (syslogd 3 System Console 4 Port Logs 4 Viewing and Configuring System Message Logs 4 Viewing System Messages from - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 6
Responding to a System Message 11 Looking Up a System Message 11 Gathering Information About the Problem 12 Support 12 Panic Dump and Core Dump Files 12 Trace Dumps 13 supportSave Command 13 System Module Descriptions 13 Section I RASLog Messages Chapter 2 AG System Messages - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 7
Chapter 3 AG-1026 31 AG-1027 32 AG-1028 32 AG-1029 32 AUTH System Messages AUTH-1001 33 AUTH-1002 33 AUTH-1003 33 AUTH-1004 34 AUTH-1005 34 AUTH-1006 34 AUTH-1007 34 AUTH- - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 8
Chapter 4 Chapter 5 AUTH-1037 43 AUTH-1038 43 AUTH-1039 43 AUTH-1040 44 AUTH-1041 44 AUTH-1042 44 AUTH-1043 45 AUTH-1044 45 BKSW System Messages BKSW-1003 47 BL System Messages BL-1000 49 BL-1001 49 BL-1002 49 BL-1003 50 BL-1004 50 BL-1006 50 BL-1007 51 BL-1008 51 BL-1009 51 BL- - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 9
Chapter 6 Chapter 7 Chapter 8 BL-1025 57 BL-1026 57 BL-1027 58 BL-1028 58 BL-1029 58 BL-1030 59 BL-1031 59 BL-1032 59 BL-1033 59 BL-1034 60 BL-1035 60 BL-1036 60 BL-1037 61 BLL System Messages BLL-1000 63 BM System Messages BM-1001 65 BM-1002 65 BM-1003 65 BM-1004 66 BM-1005 66 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 10
C2-1005 72 Chapter 9 CDR System Messages CDR-1001 73 CDR-1002 73 CDR-1003 73 CDR-1004 74 Chapter 10 CER System Messages CER-1001 75 Chapter 11 CHASSIS System Messages CHASSIS-1002 77 CHASSIS-1003 77 CHASSIS-1004 77 CHASSIS-1005 78 Chapter 12 CNM System Messages CNM-1001 79 CNM- - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 11
CNM-1021 84 CNM-1022 84 CNM-1023 84 CNM-1024 84 CNM-1025 85 CNM-1026 85 CNM-1027 85 CNM-1028 85 CNM-1029 86 CNM-1030 86 CNM-1031 86 CNM-1032 86 CNM-1033 87 CNM-1034 87 CNM-1035 87 CNM-1036 87 CNM-1037 88 CNM-1038 88 CNM-1039 88 CNM-1040 88 CNM-1041 89 CNM-1042 89 CNM-1043 89 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 12
CVLC-1015 98 CVLC-1016 99 CVLC-1017 99 CVLC-1018 99 CVLC-1019 99 CVLC-1020 100 CVLC-1021 100 CVLC-1022 100 Chapter 16 CVLMSystem Messages CVLM-1001 101 CVLM-1002 101 CVLM-1003 101 CVLM-1004 101 CVLM-1005 102 CVLM-1006 102 CVLM-1007 102 CVLM-1008 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 13
Fabric OS Message Reference 53-1001157-01 EM-1002 105 EM-1003 105 EM-1004 106 EM-1005 106 EM-1006 107 EM-1007 107 EM-1008 107 EM-1009 108 EM-1010 108 EM-1011 108 EM-1012 108 EM-1013 109 EM-1014 109 EM-1015 109 EM-1016 110 EM-1017 110 EM-1018 110 EM-1019 110 EM-1028 111 EM-1029 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 14
EM-1055 117 EM-1056 117 EM-1057 117 EM-1058 118 EM-1059 118 EM-1060 118 EM-1061 119 EM-1062 119 EM-1063 119 EM-1064 119 EM-1065 120 EM-1066 120 EM-1067 120 EM-1068 121 EM-1069 121 EM-1070 121 EM-2003 121 Chapter 18 ESS System Messages ESS-1001 123 ESS-1002 123 ESS-1003 123 ESS- - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 15
FABR-1010 130 FABR-1011 130 FABR-1012 130 FABR-1013 131 FABR-1014 131 FABR-1015 131 FABR-1016 132 FABR-1017 132 FABR-1018 132 FABR-1019 132 FABR-1020 133 FABR-1021 133 FABR-1022 133 FABR-1023 134 FABR-1024 134 FABR-1029 134 FABR-1030 135 FABR-1031 135 FABR-1032 135 FABR-1034 136 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 16
FABS-1006 142 FABS-1007 142 FABS-1008 143 FABS-1009 143 FABS-1010 143 FABS-1011 143 FABS-1012 144 FABS-1013 144 FABS-1014 144 FABS-1015 145 Chapter 22 FBC System Messages FBC-1001 147 Chapter 23 FCIP System Messages FCIP-1000 149 FCIP-1001 149 FCIP-1002 149 FCIP-1003 149 FCIP-1004 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 17
Fabric OS Message Reference 53-1001157-01 FCR-1005 158 FCR-1006 158 FCR-1007 158 FCR-1008 158 FCR-1009 159 FCR-1010 159 FCR-1011 159 FCR-1012 160 FCR-1013 160 FCR-1015 160 FCR-1016 160 FCR-1018 161 FCR-1019 161 FCR-1020 161 FCR-1021 162 FCR-1022 162 FCR-1023 162 FCR-1024 163 FCR- - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 18
FCR-1048 168 FCR-1049 168 FCR-1053 169 FCR-1054 169 FCR-1055 169 FCR-1056 170 FCR-1057 170 FCR-1058 170 FCR-1059 171 FCR-1060 171 FCR-1061 171 FCR-1062 171 FCR-1063 172 FCR-1064 172 FCR-1065 172 FCR-1066 173 FCR-1067 173 FCR-1068 173 FCR-1069 173 FCR-1070 174 FCR-1071 174 FCR- - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 19
FCR-1088 179 FCR-1089 179 Chapter 28 FICON System Messages FICN-1003 181 FICN-1004 181 FICN-1005 182 FICN-1006 182 FICN-1007 182 FICN-1008 183 FICN-1009 183 FICN-1010 183 FICN-1011 183 FICN-1012 184 FICN-1013 184 FICN-1014 184 FICN-1015 185 FICN-1016 185 FICN-1017 185 FICN-1018 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 20
FICN-1036 190 FICN-1037 190 FICN-1038 191 FICN-1039 191 FICN-1040 191 FICN-1041 192 FICN-1042 192 FICN-1043 192 FICN-1044 192 FICN-1045 193 FICN-1046 193 FICN-1047 193 FICN-1048 194 FICN-1049 194 FICN-1050 194 FICN-1051 194 FICN-1052 195 FICN-1053 195 FICN-1054 195 FICN-1055 195 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 21
FICN-1073 200 FICN-1074 201 FICN-1075 201 FICN-1076 201 FICN-1077 202 FICN-1078 202 FICN-1079 202 FICN-1080 203 FICN-1081 203 FICN-1082 203 FICN-1083 204 FICN-1084 204 FICN-1085 204 FICN-1086 204 Chapter 29 FICU System Messages FICU-1001 205 FICU-1002 205 FICU-1003 205 FICU-1004 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 22
Chapter 32 FSPF System Messages FSPF-1001 213 FSPF-1002 213 FSPF-1003 213 FSPF-1005 214 FSPF-1006 214 Chapter 33 FSS System Messages FSS-1001 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 23
Fabric OS Message Reference 53-1001157-01 FW-1033 224 FW-1034 224 FW-1035 225 FW-1036 225 FW-1037 225 FW-1038 226 FW-1039 226 FW-1040 226 FW-1041 227 FW-1042 227 FW-1043 227 FW-1044 228 FW-1045 228 FW-1046 228 FW-1047 228 FW-1048 229 FW-1049 229 FW-1050 229 FW-1051 230 FW-1052 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 24
FW-1130 236 FW-1131 236 FW-1132 237 FW-1133 237 FW-1134 237 FW-1135 238 FW-1136 238 FW-1137 238 FW-1138 238 FW-1139 239 FW-1140 239 FW-1160 239 FW-1161 240 FW-1162 240 FW-1163 240 FW-1164 241 FW-1165 241 FW-1166 241 FW-1167 242 FW-1168 242 FW-1169 242 FW-1170 243 FW-1171 243 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 25
-1240 253 FW-1241 254 FW-1242 254 FW-1243 254 FW-1244 255 FW-1245 255 FW-1246 255 FW-1247 256 FW-1248 256 FW-1249 256 FW-1250 256 FW-1251 257 FW-1272 257 FW-1273 257 FW-1274 258 FW-1275 258 FW-1296 258 FW-1297 259 FW - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 26
FW-1299 259 FW-1300 260 FW-1301 260 FW-1302 260 FW-1303 261 FW-1304 261 FW-1305 261 FW-1306 262 FW-1307 262 FW-1308 262 FW-1309 263 FW-1310 263 FW-1311 263 FW-1312 264 FW-1313 264 FW-1314 264 FW-1315 265 FW-1316 265 FW-1317 265 FW-1318 266 FW-1319 266 FW-1320 266 FW-1321 267 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 27
Fabric OS Message Reference 53-1001157-01 FW-1336 272 FW-1337 272 FW-1338 272 FW-1339 273 FW-1340 273 FW-1341 273 FW-1342 274 FW-1343 274 FW-1344 274 FW-1345 275 FW-1346 275 FW-1347 275 FW-1348 276 FW-1349 276 FW-1350 276 FW-1351 277 FW-1352 277 FW-1353 278 FW-1354 278 FW-1355 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 28
FW-1373 284 FW-1374 285 FW-1375 285 FW-1376 285 FW-1377 286 FW-1378 286 FW-1379 286 FW-1400 287 FW-1401 287 FW-1402 287 FW-1403 288 FW-1424 288 FW-1425 288 FW-1426 288 FW-1427 289 FW-1428 289 FW-1429 289 FW-1430 290 FW-1431 290 FW-1432 290 FW-1433 290 FW-1434 291 FW-1435 291 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 29
Chapter 36 HAM System Messages HAM-1001 297 HAM-1002 297 HAM-1004 297 HAM-1005 298 HAM-1006 298 HAM-1007 299 HAM-1008 299 HAM-1009 299 Chapter 37 HAMK System Messages HAMK-1001 301 HAMK-1002 301 HAMK-1003 301 HAMK-1004 302 Chapter 38 HIL System Messages HIL-1101 303 HIL-1102 303 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 30
HIL-1306 309 HIL-1307 309 HIL-1308 309 HIL-1309 310 HIL-1310 310 HIL-1311 310 HIL-1401 310 HIL-1402 311 HIL-1403 311 HIL-1404 311 HIL-1501 311 HIL-1502 312 HIL-1503 312 HIL-1504 312 HIL-1505 313 HIL-1506 313 HIL-1507 313 HIL-1508 314 HIL-1509 314 HIL-1510 314 HIL-1601 315 HIL- - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 31
333 IPS-1002 333 IPS-1003 333 IPS-1004 333 IPS-1005 334 IPS-1006 334 Chapter 47 ISCS System Messages ISCS-1000 335 Chapter 48 ISNS System Messages ISNS-1001 337 ISNS-1002 337 ISNS-1003 337 ISNS-1004 338 Fabric OS Message Reference xxxi 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 32
ISNS-1005 338 ISNS-1006 338 ISNS-1008 338 ISNS-1009 339 ISNS-1010 339 ISNS-1011 339 ISNS-1013 339 ISNS-1014 340 Chapter 49 KAC System Messages KAC-1002 341 KAC-1004 341 KAC-1006 341 KAC-1007 341 KAC-1008 342 Chapter 50 KSWD System Messages KSWD-1001 343 KSWD-1002 343 KSWD-1003 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 33
LOG-1001 349 LOG-1002 349 LOG-1003 350 Chapter 54 LSDB System Messages LSDB-1001 351 LSDB-1002 351 LSDB-1003 351 LSDB-1004 352 Chapter 55 MFIC System Messages MFIC-1001 353 MFIC-1002 353 MFIC-1003 353 Chapter 56 MPTH System Messages MPTH-1001 355 MPTH-1002 355 MPTH-1003 355 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 34
Chapter 59 NBFS System Messages NBFS-1001 365 NBFS-1002 365 NBFS-1003 366 Chapter 60 NS System Messages NS-1001 367 NS-1002 367 NS-1003 367 NS-1004 368 NS-1005 368 NS-1006 368 Chapter 61 PDM System Messages PDM-1001 369 PDM-1002 369 PDM-1003 369 PDM-1004 370 PDM-1005 370 PDM-1006 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 35
1000 379 PLAT-1001 379 PLAT-1002 379 PLAT-1003 380 Chapter 64 PMGR System Messages PMGR-1001 381 PMGR-1002 381 PMGR-1003 PMGR-1008 382 PMGR-1009 383 PMGR-1010 383 Chapter 65 PORT System Messages PORT-1003 385 PORT-1004 385 PORT-1005 385 Chapter 66 PS System Messages PS-1000 387 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 36
Chapter 68 RAS System Messages RAS-1001 391 RAS-1002 391 RAS-1004 391 RAS-1005 391 RAS-1006 392 RAS-2001 392 RAS-2002 392 RAS-2003 392 RAS-3001 393 RAS-3002 393 RAS-3003 393 RAS-3004 393 Chapter 69 RCS System Messages RCS-1001 395 RCS-1002 395 RCS-1003 395 RCS-1004 396 RCS-1005 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 37
Chapter 72 RTWR System Messages RTWR-1001 403 RTWR-1002 403 RTWR-1003 404 Chapter 73 SAS System Messages SAS-1001 405 Chapter 74 SCN System Messages SCN-1001 407 Chapter 75 SEC System Messages SEC-1001 409 SEC-1002 409 SEC-1003 410 SEC-1005 410 SEC-1006 410 SEC-1007 411 SEC-1008 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 38
xxxviii SEC-1042 417 SEC-1043 417 SEC-1044 417 SEC-1045 417 SEC-1046 418 SEC-1049 418 SEC-1050 418 SEC-1051 419 SEC-1052 419 SEC-1053 419 SEC-1054 420 SEC-1055 420 SEC-1056 420 SEC-1057 421 SEC-1059 421 SEC-1062 421 SEC-1063 421 SEC-1064 422 SEC-1065 422 SEC-1069 422 SEC-1071 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 39
Fabric OS Message Reference 53-1001157-01 SEC-1088 427 SEC-1089 427 SEC-1090 428 SEC-1091 428 SEC-1092 428 SEC-1093 428 SEC-1094 429 SEC-1095 429 SEC-1096 429 SEC-1097 430 SEC-1098 430 SEC-1099 430 SEC-1100 430 SEC-1101 431 SEC-1102 431 SEC-1104 431 SEC-1105 432 SEC-1106 432 SEC- - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 40
SEC-1136 437 SEC-1137 438 SEC-1138 438 SEC-1139 438 SEC-1142 439 SEC-1145 439 SEC-1146 439 SEC-1153 440 SEC-1154 440 SEC-1155 440 SEC-1156 441 SEC-1157 441 SEC-1158 441 SEC-1159 442 SEC-1160 442 SEC-1163 442 SEC-1164 442 SEC-1165 443 SEC-1166 443 SEC-1167 443 SEC-1168 443 SEC- - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 41
Fabric OS Message Reference 53-1001157-01 SEC-1189 448 SEC-1190 449 SEC-1191 449 SEC-1192 449 SEC-1193 449 SEC-1194 450 SEC-1195 450 SEC-1196 450 SEC-1197 451 SEC-1198 451 SEC-1199 451 SEC-1200 451 SEC-1201 452 SEC-1202 452 SEC-1203 452 SEC-1250 453 SEC-1251 453 SEC-1253 453 SEC- - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 42
SEC-1319 459 SEC-1320 459 SEC-1321 459 SEC-1322 460 SEC-1323 460 SEC-1324 460 SEC-1325 460 SEC-1326 461 SEC-1327 461 SEC-1328 461 SEC-1329 462 SEC-1330 462 SEC-1331 462 SEC-1332 462 SEC-1333 463 SEC-3035 463 SEC-3036 463 SEC-3037 464 SEC-3038 464 SEC-3039 464 SEC-3050 464 SEC- - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 43
SPC-2001 472 SPC-2002 472 SPC-2003 472 SPC-2004 472 SPC-2005 473 SPC-2006 473 SPC-2007 473 SPC-2008 473 SPC-2009 474 SPC-2010 474 SPC-2011 474 SPC-2012 474 SPC-3001 475 SPC-3002 475 SPC-3003 475 SPC-3004 475 SPC-3005 476 SPC-3006 476 SPC-3007 477 SPC-3008 477 SPC-3009 477 SPC- - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 44
SPM-1009 483 SPM-1010 483 Chapter 79 SS System Messages SS-1000 485 SS-1001 485 SS-1002 485 SS-1003 486 Chapter 80 SULB System Messages SULB-1001 487 SULB-1002 487 SULB-1003 487 SULB-1004 488 SULB-1005 488 SULB-1006 488 SULB-1007 488 SULB-1008 489 SULB-1009 489 SULB-1010 495 SULB - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 45
SULB-1037 500 Chapter 81 SWCH System Messages SWCH-1001 501 SWCH-1002 501 SWCH-1003 501 SWCH-1004 502 SWCH-1005 502 SWCH-1006 502 SWCH-1007 502 SWCH-1008 503 SWCH-1009 503 SWCH-1010 503 SWCH-1011 504 Chapter 82 SYSC System Messages SYSC-1001 505 SYSC-1002 505 SYSC-1003 505 SYSC- - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 46
TRCE-1004 512 TRCE-1005 512 TRCE-1006 512 TRCE-1007 513 TRCE-1008 513 TRCE-1009 513 TRCE-1010 513 TRCE-1011 514 TRCE-1012 514 Chapter 86 TRCK System Messages TRCK-1001 515 TRCK-1002 515 TRCK-1003 515 TRCK-1004 515 TRCK-1005 516 TRCK-1006 516 Chapter 87 TS System Messages TS-1001 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 47
WEBD-1002 525 WEBD-1004 525 WEBD-1005 525 WEBD-1006 526 WEBD-1007 526 WEBD-1008 526 Chapter 91 ZOLB System Messages ZOLB-1001 527 Chapter 92 ZONE System Messages ZONE-1002 529 ZONE-1003 529 ZONE-1004 529 ZONE-1005 530 ZONE-1006 530 ZONE-1007 531 ZONE-1008 531 ZONE-1010 531 ZONE- - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 48
ZONE-1034 537 ZONE-1035 537 ZONE-1036 537 ZONE-1037 538 ZONE-1038 538 ZONE-1039 538 ZONE-1040 538 ZONE-1041 539 ZONE-1042 539 ZONE-1043 539 ZONE-1044 539 ZONE-1045 540 ZONE-1046 540 ZONE-1047 540 ZONE-1048 540 ZONE-1049 541 ZONE-1050 541 ZONE-1051 541 ZONE-1052 541 ZONE-1053 542 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 49
HTTP System Messages HTTP-1002 559 HTTP-1003 559 Chapter 96 AUDIT IPAD System Messages IPAD-1002 561 Chapter 97 AUDIT PORT System Messages PORT-1006 563 PORT-1007 563 PORT-1008 563 PORT-1009 563 Chapter 98 AUDIT SEC System Messages SEC-3001 565 SEC-3002 565 SEC-3003 565 SEC-3004 566 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 50
SEC-3012 568 SEC-3013 568 SEC-3014 569 SEC-3015 569 SEC-3016 569 SEC-3017 570 SEC-3018 570 SEC-3019 570 SEC-3020 570 SEC-3021 571 SEC-3022 571 SEC-3023 571 SEC-3024 572 SEC-3025 572 SEC-3026 572 SEC-3027 572 SEC-3028 573 SEC-3029 573 SEC-3030 573 SEC-3031 574 SEC-3032 574 SEC- - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 51
SEC-3051 578 Chapter 99 AUDIT SNMP System Messages SNMP-1004 579 SNMP-1005 579 SNMP-1006 579 Chapter 100 AUDIT SULB System Messages SULB-1001 581 SULB-1002 581 SULB-1003 581 SULB-1004 582 SULB-1009 582 SULB-1010 588 SULB-1017 588 SULB-1018 588 SULB-1020 589 SULB-1021 589 SULB-1023 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 52
UCST-1024 596 UCST-1025 596 UCST-1026 596 UCST-1027 596 Chapter 103 AUDIT ZONE System Messages ZONE-3001 599 ZONE-3002 599 ZONE-3003 599 ZONE-3004 600 ZONE-3005 600 ZONE-3006 600 ZONE-3007 601 ZONE-3008 601 ZONE-3009 601 ZONE-3010 601 ZONE-3011 602 ZONE-3012 602 ZONE-3013 602 ZONE- - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 53
procedures documented here apply to some switches but not to others, this guide identifies exactly which switches are supported and which are not. Although many different software and hardware configurations are tested and supported by Brocade Communications Systems, Inc. for 5.3.0, documenting all - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 54
• Brocade 4018 switch • Brocade 4020 switch • Brocade 4024 switch • Brocade 4100 switch • Brocade 4900 switch • Brocade 5000 switch • Brocade 5100 switch • Brocade 5300 switch • Brocade 7500 Extension Switch • Brocade 7500E Extension Switch • Brocade 7600 switch • Brocade 48000 director • Brocade - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 55
For readability, command names in the narrative portions of this guide are presented in mixed lettercase: for example, switchShow. In a command is case sensitive. Command syntax conventions Command syntax in this manual follows these conventions: command --option, option -argument, arg [ ] - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 56
are used in this manual. They are listed or cause damage to hardware, firmware, software, or data. DANGER A SAN design, implementation, and maintenance, you can obtain Building SANs with Brocade Fabric Switches through: http://www.amazon.com For additional Brocade documentation, visit the Brocade - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 57
, visit the Fibre Channel Industry Association Web site: http://www.fibrechannel.org Getting technical help Contact your switch support supplier for hardware, firmware, and software support, including product repairs and part ordering. To expedite your call, have the following information available - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 58
the port side of the chassis, directly above the cable management comb. 3. World Wide Name (WWN) Use the wwn command to display the switch WWN. • If you cannot use the wwn command because the switch is inoperable, you can get the WWN from the same place as the serial number, except for the Brocade - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 59
guide supports Fabric OS v6.2.0 and documents system messages that can help you diagnose and fix problems with a switch or fabric. The messages are organized first by event type, reliability, availability, and serviceability number is persistent across power cycles and switch reboots. • By default - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 60
support post-event audits and problem determination based on high-frequency events of certain types such as security violations, zoning configuration changes, firmware downloads saved in the switch's error logs. Instead, the switch can be configured to stream Audit messages to the switch console and - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 61
that supports the standard syslogd functionality. Configuring for syslogd involves configuring the host, enabling syslogd on the Brocade model, and, optionally, setting the facility level. For the Brocade DCX, 24000 and 48000, each CP has a unique error log, depending on which CP was active when - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 62
log of all port activity. Each switch or logical switch maintains a log file for each port. Port logs are circular buffers that can save up to 8000 entries per logical switch. When the log is full, the newest log entries overwrite the oldest log entries. Port logs capture switch-to-device, device - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 63
(Power-On Self-Test) configuration. errClear Clears all error log messages for all switch port log. Port log events are described by the portLogEventShow command. setVerbose Sets the verbose level of a particular module within the Fabric OS. supportFtp Sets, clears, or displays support - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 64
(active CP only) information for the local CP and then transfers the files to an FTP server. The operation can take several minutes. supportShow Executes a list of diagnostic and error display commands. This output is used by your switch service provider to diagnose and correct problems with - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 65
, HA State out of sync Type to continue, Q to stop: 2004/07/28-17:04:51, [EM-1055], 3,, WARNING, switch, Media 27: Port media incompatible e. Reason: Configured port speed. Type to continue, Q to stop: Clearing the System Message Log To clear the system message log for a particular - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 66
switch:admin> auditcfg --show Audit filter is enabled. 1-ZONE 2-SECURITY 3-CONFIGURATION 4-FIRMWARE 5-FABRIC 3. Enable the audit feature: switch:admin when the message was generated on the switch. The RASLog subsystem supports an internationalized timestamp format base on the "LOCAL" setting. The - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 67
across power cycles and switch reboots. 16 characters in length. Run either the chassisName command to name the chassis or the switchName command to rename the logical switch. Error Description A text string explaining the error encountered and providing parameters supplied by the software - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 68
as an Audit message. Date and Time Stamp The system time (UTC) when the message was generated on the switch. The RASLog subsystem will support an internationalized timestamp format base on the "LOCAL" setting. Message Module and Message Number The message module and number. These values uniquely - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 69
including: •Looking Up a System Message 11 •Gathering Information About the Problem 12 •Support 12 •Panic Dump and Core Dump Files 12 •Trace Dumps 13 •supportSave Command 13 Looking Up a System Message Error messages in this manual are arranged alphabetically. To look up an error message, copy - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 70
port (console) logs available? 12. Which CP was master? (only applicable to the Brocade DCX, 12000, 24000, or 48000) 13. What and when were the last actions or changes made to the system? Support Fabric OS creates a number of files that can help support personnel troubleshoot and diagnose a problem - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 71
within the switch platform, for example: Brocade DCC contains FC8-48, FC9-32, and FC8-16 blades. Table 5 provides a summary of the system modules for which messages are documented in this reference guide; the system modules are listed alphabetically by name. TABLE 5 System Module Descriptions - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 72
the domain and alias lists to all switches in the fabric. Fabric OS system driver module. Firmware blade compatibility errors with control processor (CP). Fibre Channel over IP port configuration messages. Fibre Channel miscellaneous messages relate to problems with the physical layer used to send - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 73
messages indicate that something has occurred which affects the control unit port (CUP) for the switch/director. These messages can mean anything from configuration-related failures to internal software errors. The FICON-CUP daemon handles communication with fibre connectivity (FICON) on IBM FICON - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 74
not only switch wide, but tunneling, and port-related messages problems associated with Fabric OS and the external key vaults. The kernel software Blade Manager (bmd) • Common Access Layer (cald) • Diagnostics daemon (diagd) • Environment Monitor (emd) • EVM daemon (evmd) • Exchange Service Support - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 75
unit port (FICON-CUP) process or interrupt service routine (ISR active CP blade to the standby CP blade. These messages indicate panic dump trace files have been created. This message indicates hardware problems. A group of messages relating to logical switch creation, deletion and configuration. PORT - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 76
are any problems during the firmwareDownload procedure. Most messages are informational only and are generated even during successful firmware download. For additional information, refer to the Fabric OS Administrator's Guide. These messages are generated by the switch driver module that manages - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 77
OS Administrator's Guide. Time Service provides fabric time-synchronization by synchronizing all clocks in the fabric to the clock time on the principal switch. UCST is problems with the Web Tools module. Indicates problems with the zone library module. The zone module messages indicate any problems - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 78
1 System Module Descriptions 20 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 79
RASLog Messages Section I This section provides the RASLog messages, including: •AG System Messages 25 •AUTH System Messages 33 •BKSW System Messages 47 •BL System Messages 49 •BLL System Messages 63 •BM System Messages 65 •C2 System Messages 71 •CDR System Messages 73 •CER System Messages - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 80
Messages 365 •NS System Messages 367 •PDM System Messages 369 •PDTR System Messages 377 •PLAT System Messages 379 •PMGR System Messages 381 •PORT System Messages 385 •PS System Messages 387 •PSWP System Messages 389 •RAS System Messages 391 •RCS System Messages 395 •RKD System Messages - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 81
•RTWR System Messages 403 •SAS System Messages 405 •SCN System Messages 407 •SEC System Messages 409 •SNMP System Messages 467 •SPC System Messages 471 •SPM System Messages 481 •SS System Messages 485 •SULB System Messages 487 •SWCH System Messages 501 •SYSC System Messages 505 •SYSM - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 82
- HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 83
. • Some blades and ports in a switch may not support NPIV. NPIV functionality can not be enabled on such ports and they will not respond to NPIV requests. Refer to the Access Gateway Administrator Guide, Appendix B, for specific AG-compatibility requirements. • On non-Brocade switches, refer to - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 84
login (FLOGI) request from the fabric for N_Port . Probable Cause Indicates the fabric sent an invalid response to the FLOGI Extended Link Service (ELS) for the specified N_Port. Recommended Action Check the configuration of the fabric switch. If the message persists, run supportFtp (as - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 85
-name>, Invalid port login (PLOGI) response from the fabric on the N_Port . Probable Cause Indicates the fabric switch management server did FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING AG-1009 Message , [AG-1009 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 86
system-name>, Sending FDISC failed on N_Port . Probable Cause Indicates there was a failure sending discover F_Port service parameter request from the Access Gateway to the fabric switch. Recommended Action Check the configuration of the fabric switch connected to the Access Gateway. If the - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 87
; then run the supportsave command and contact your switch service provider. Severity WARNING AG-1016 Message , port> to other N_Ports. Probable Cause Indicates the specified N_Port has failed to come online. All F_Ports mapped to this N_Port are being failed over to other active - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 88
>, [AG-1019], ,, WARNING, , Unable to failover N_Port . No other N Port in port group: is online. Probable Cause Indicates that failover across port groups is not supported. Recommended Check whether or not an alternate N_Port is configured in this - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 89
while the Trunk Area assigned to the attached F_Ports on the edge switch is the same. Recommended Run the porttrunkarea --show command on the attached switch to display that the Trunk Area is Action assigned to all ports in the system and run porttrunkarea --enable to reconfigure the Trunk Area - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 90
your switch service provider. Severity WARNING AG-1027 Message , [AG-1027], ,, WARNING, , Unable to handle this login request on port because . Recommended No action is required. Action Severity INFO 32 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 91
Retry the secAuthSecret command. Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1003 Message , [AUTH-1003], ,, INFO, , type has been - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 92
run the supportSave command and contact your switch service provider. Severity WARNING AUTH-1007 Message Probable Cause , [AUTH-1007], ,, ERROR, , The proposed authentication protocols are not supported: port . Indicates that the proposed - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 93
sure the local switch supports the specified protocols: problem with the Secure Fabric OS. Recommended Action Reboot or power cycle the switch. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 94
supportSave command and contact your switch service provider. Severity WARNING AUTH-1014 Message , [AUTH-1014], , FFDC, ERROR, , Invalid port value to : port . Probable Cause Indicates an internal problem with the Secure Fabric OS - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 95
the supportSave command and contact your switch service provider. Severity ERROR AUTH-1018 Message , [AUTH-1018], ,, ERROR, , Invalid value to check protocol type: port . Probable Cause Indicates an internal problem with the Secure Fabric OS - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 96
run the supportSave command and contact your switch service provider. Severity INFO AUTH-1022 Message - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 97
port . Probable Cause Indicates that the authentication process failed to select an authentication value (that is, DH Group, hash value, or protocol type) from a receiving payload for the specified authentication phase. This indicates that the local switch does not support the - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 98
your switch service provider. port number>, retval . Probable Cause Indicates that the authentication process failed to get a particular authentication value at certain phase. Data type is the payload or structure that failed to get memory. Recommended Action Usually this problem - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 99
replay attacks. Recommended Action Usually this problem is transient. The authentication might fail. switch service provider. Severity ERROR AUTH-1033 Message , [AUTH-1033], ,, ERROR, , Disable port due to unauthorized switch - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 100
FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1035 Message , [AUTH-1035 port . Probable Cause Indicates that the switch received an unexpected authentication message. Recommended Action Usually this problem - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 101
service provider. Severity ERROR AUTH-1039 Message Probable Cause , [AUTH-1039], ,, ERROR, , Neighboring switch has conflicting authentication policy: Port disabled. Indicates that the neighboring switch has a conflicting authentication - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 102
FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1042 Message Probable Cause , [AUTH-1042], ,, ERROR, , Port has been disabled, because authentication failed with code ' - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 103
command and contact your switch service provider. Severity ERROR AUTH authentication policy manually using the port>. Disabling port . Probable Cause Indicates authentication has timed out after multiple retries. The specified port has been disabled as a result. This problem - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 104
3 AUTH-1044 46 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 105
is found, run supportFtp to send all core files to a secure server location. Copy the error message and any core file information, and contact your switch service provider. Severity WARNING Fabric OS Message Reference 47 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 106
4 BKSW-1003 48 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 107
correctly. If the blade is seated correctly, reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Note that any reference seen to slot 0 is a reference to the blade within the switch platform, e.g.,Brocade 7500 and AP7600 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 108
Recommended Action Make sure that the blade is seated correctly. If the blade is seated correctly, reboot or power cycle the blade. Run the systemVerification command to verify that blade does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 109
1007 5 Probable Cause Indicates that the errors (mostly synchronization errors) on this blade are harmless. Probably, the standby control processor (CP) blade connected to the active CP blade has experienced transitory problems. Recommended Use the haShow command to verify that the standby CP is - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 110
(SFP), or device attached to the specified port. Run the systemVerification command to verify that the blade or switch does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. On a bladed switch, run the slotPowerOff and slotPowerOn commands. On - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 111
factor pluggable (SFP), or device attached to the specified port. On a bladed switch, run the slotPowerOff and slotPowerOn commands. On a nonbladed switch, reboot or power cycle the switch. If the message persists, replace the blade. Severity ERROR BL-1014 Message Probable Cause , [BL - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 112
the diagPost command to ensure that Power-On Self-Test (POST) is enabled. If there is a hardware error, if the slotPowerOff or slotPowerOn fails on the bladed switch or if errors are encountered again: • On the Brocade DCX, 24000, and 48000, replace the blade field-replaceable unit (FRU). • On the - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 113
blade is seated correctly. If the blade is seated correctly, reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Run the diagPost command to ensure that Power slot has completed initializing the ports. Recommended No action is - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 114
one or more of the internal ports was not online. The switch is faulted. Recommended Action Reboot or power cycle the switch. Run the systemVerification command to verify that the switch does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 115
Action Reboot or power cycle the blade. If the message persists, replace the blade. Severity CRITICAL BL-1024 Message , [BL-1024], ,, INFO, , All ports on the blade in slot will be reset as part of the firmware upgrade. Probable Cause - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 116
Recommended Action Reboot or power cycle the switch. If the message persists, replace the switch. Severity CRITICAL BL-1029 Message , [BL-1029], ,, INFO, , All ports on the switch will be reset as part of the firmware upgrade. Probable Cause Indicates - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 117
Indicates that back-end (non-user) ports have not come ONLINE within time limit. Recommended Action Reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 118
waiting for disable messages from the user ports after disabling the ports. Recommended Action Reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 119
-number>,, CRITICAL, , Faulting chip in slot = , miniS = ,port = due to BE/BI port fault. Probable Cause Fault the chip and disable all the ports on that chip. Recommended No action is required. Action Severity CRITICAL Fabric OS Message - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 120
5 BL-1037 62 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 121
BLL-1000], , FFDC, CRITICAL, , ASIC driver detected Slot port as faulty (reason: ) Probable Cause Indicates a blade regulation problem was reported on the specified slot number. The blade is faulted. The possible reason codes are as - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 122
6 BLL-1000 If the message persists, replace the blade. Severity CRITICAL 64 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 123
to determine whether a non-disruptive firmware download is supported between the versions. As the AP and CP blades cannot communicate, it is not possible to load new firmware on the AP blade. If needed, send the AP blade back to the factory for a firmware update. Severity ERROR BM-1002 Message - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 124
On the Brocade Action 7500 or 7600, switch off and on all primary power to power-cycle the unit. Severity WARNING BM-1006 Message , [BM-1006], ,, INFO, , Blade is not configured. Persistently disabling all ports for blade in slot . Probable - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 125
. On the Brocade Action 7500 or 7600, switch off and on all primary power in order to power-cycle the unit. Severity WARNING BM-1010 Message Probable Cause , [BM-1010], ,, INFO, , Resetting port configuration and linkcost for all ports for blade in slot - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 126
On the Brocade 7500 or 7600, switch off and on all primary power to power-cycle the unit. Action Severity WARNING BM-1054 Message , [BM-1054], ,, INFO, , AP firmware is not consistent with system firmware . Auto-leveling - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 127
under a different mode. Recommended Configure the switch to persistently enable all ports. Action Severity INFO BM-1058 Message , [BM-1058], ,, WARNING, , Download of AP firmware failed for the switch. Reissue firmwaredownload to recover. Probable Cause - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 128
7 BM-1058 70 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 129
name>, Port port fault (the configured speed may not be supported by the ports on the blade/switch will be disrupted. Recommended For a bladed system, perform slotpoweroff and slotpoweron on the blade to recover the system. For Action a non-bladed system, perform fastboot on the switch - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 130
,, ERROR, , Rate limit configuration is not effective on S() user port because QoS license is not present. Probable Cause Indicates that the switch does not have the QoS license added. Rate Limit is a licensed feature and requires QoS license - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 131
, , Port chip faulted due to internal error. Probable Cause Internal error. Recommended For a bladed system, issue the slotPowerOff and slotPowerOn commands on the blade to recover Action the system. For a non-bladed system, perform fastBoot on the switch to recover the - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 132
specific integrated circuit (ASIC) hardware that may degrade data traffic. Recommended Whenever this error occurs, reboot the system at the next maintenance window. If the problem Action persists, replace the blade. Severity ERROR 74 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 133
Cause Indicates that the high-availability (HA) synchronization between the active and standby control processors (CPs) is broken, because there is downlevel firmware loaded on the standby CP. The standby CP does not support the Advanced Performance Tuning module when the fibre connectivity (FICON - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 134
10 CER-1001 76 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 135
command followed by the slotPowerOn Action command. On a Brocade 7500 or AP7600 switch, reboot or power cycle the switch. Severity ERROR CHASSIS-1004 Message , [CHASSIS-1004], ,, ERROR, , Blade attach failed during recovery, disabling slot = - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 136
blade attach has failed during failover or recovery. Recommended Action On a Brocade 24000 or 48000 switch, run the slotPowerOff command followed by the slotPowerOn command. On a Brocade 200E, 3250, 3850, 3900, 4012, 4016, 4018, 4020, 4024, 4100, 4900, 5000, 7500, or AP7600 switch, reboot or power - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 137
power cycle the Action switch. Severity ERROR CNM-1002 Message , [CNM-1002], ,, ERROR, , Failed to initialize rc = . Probable Cause Indicates that an initialization of a module within the CNM failed. Recommended Download a new firmware - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 138
12 CNM-1005 Probable Cause Indicates that the Crypto service is enabled or disabled on the switch. Recommended No action is required. Action Severity INFO CNM-1005 Message , [CNM-1005], ,, INFO, , Posting event CNM_EVT_GRP_LEADER_ELECTED Name [ - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 139
12 CNM-1009 Recommended No action is required. Action Severity INFO CNM-1009 Message , [CNM-1009], ,, INFO, , Posting event CNM_EVT_STANDALONE_MODE. Probable Cause Indicates that the node is in standalone mode. Recommended No action is required. Action - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 140
12 CNM-1013 Recommended No action is required. Action Severity INFO CNM-1013 Message , [CNM-1013], ,, INFO, ,Posting event GL Node Split condition, isolating peer GL node . Probable Cause Indicates that the encryption group (EG) is split. - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 141
12 CNM-1017 Recommended No action is required. Action Severity INFO CNM-1017 Message , [CNM-1017], ,, INFO, ,Got JOIN REQUEST from un-recognized GL node [], configured GL node is []. Probable Cause Indicates a join request was received - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 142
12 CNM-1021 Probable Cause Indicates Node Admission Control failed. Recommended No action is required. Action Severity INFO CNM-1021 Message , [CNM-1021], ,, INFO, , Failed to sign the node authentication message, admission control might fail. Probable - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 143
sequence-number>,, INFO, , Operation not allowed, as member is active with the Cluster. Eject member node and retry. Probable Cause Indicates an Received Hdr version Expected Hdr version Upgrade the firmware or delete the Node [] from the EG. Probable Cause - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 144
the certificate file failed. Recommended No action is required. Action Severity INFO CNM-1032 Message , [CNM-1032], ,, INFO, , Certfile size does not match cert file size sent by GL 86 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 145
CNM-1033 Probable Cause Indicates that there is a size mismatch between a node's certificate file and the Message , [CNM-1036], ,, INFO, , All the active nodes of the cluster are in ONLINE state. Posting converged event. Fabric OS Message Reference - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 146
12 CNM-1037 Probable Cause Indicates an event is being posted to indicate the cluster is in a converged state. Recommended No action is required. Action Severity INFO CNM-1037 Message , [CNM-1037], ,, INFO, , Split-Brain Arbitration lost!, minority GL - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 147
INFO CNM-1041 Message , [CNM-1041], ,, INFO, , Updating persistent Cluster DB, please avoid powering off the switch. Probable Cause Indicates the system is updating the persistent database. Recommended No action is required. Action Severity INFO CNM - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 148
12 CNM-1044 Recommended No action is required. Action Severity INFO 90 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 149
initiated and completed successfully. The statement that follows, message strings, is the description of the classes of configuration parameters that were downloaded. If Admin Domain (AD) is enabled, the AD number is specified in the description. Recommended No action is required. Action Severity - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 150
to be disabled. Recommended Disable the switch and try to download the configuration. Action Severity INFO CONF-1030 Message , [CONF-1030], ,, WARNING, , Configuration database full, data not committed (key:. Probable - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 151
Chapter CTAP System Messages 14 CTAP-1001 Message , [CTAP-1001], ,, INFO, , Key acquisition for . Probable Cause Indicates that a change in the tape pool database has triggered the key acquisition process for each - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 152
14 CTAP-1001 94 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 153
>. Probable Cause Indicates the First time encryption, Key expired or Manual re-key operation is performed. The operation has been started, Forceful LUN policy change to clear text while re-key session is still active.\nContainer: , Initiator: , LUN - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 154
>, Forceful encryption LUN removal while re-key session is still active.\nContainer: , Initiator: , LUN was forcefully removed while a re-key session was still active. Recommended No action is required. Action Severity INFO CVLC-1005 Message - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 155
Probable Cause , [CVLC-1012], ,, ERROR, , Disk metadata is in wrong format ().\nContainer: , Initiator: , LUN ID: . Indicates that the metadata found on - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 156
name>, Initiator: , LUN ID: . Probable Cause Indicates that the encryption engine is unable to retrieve the key record base on the key ID found in the metadata. Recommended No action is required. Action Severity ERROR CVLC-1014 Message , [CVLC-1014 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 157
15 CVLC-1016 CVLC-1016 Message , [CVLC-1016], ,, INFO, , LUN is out of read only mode. Reason: .\nContainer: , Initiator: , LUN ID: . Probable Cause Indicates - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 158
15 CVLC-1020 Severity ERROR CVLC-1020 Message , [CVLC-1020], ,, ERROR, , Metadata exists while LUN is clear text.\nContainer: , Initiator: , LUN ID: . Probable Cause Indicates that metadata exists on - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 159
or power cycle the switch. Severity ERROR CVLM-1002 Message , [CVLM-1002], ,, ERROR, , Failed to initialize rc = . Probable Cause Indicates that an initialization of a module within the CVLMD failed. Recommended Download a new firmware - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 160
the Fabric OS Command Reference Manual for more information on this command. Severity WARNING CVLM-1005 Message , [CVLM-1005], ,, INFO, , Crypto service is on the switch. Probable Cause Indicates that the Crypto service is enabled or disabled on - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 161
16 CVLM-1009 Probable Cause Indicates that the member of HAC is not in the fabric. Recommended Check the ISL port connected to the fabric. Action Severity WARNING CVLM-1009 Message , [CVLM-1009], ,, INFO, , The member ( - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 162
16 CVLM-1012 Recommended No action is required. Action Severity INFO 104 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 163
range of the switch. Refer to the hardware reference manual for the environmental temperature range of your switch. Run the fanShow is faulted. Recommended Action On Brocade 24000 and 48000, try reseating the specified FRU. Reboot or power cycle the switch. Fabric OS Message Reference - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 164
and an optional number to identify the unit, slot, or port. The Brocade 3250 has one power supply and three fans, and the Brocade 3850 has two power supplies and four fans. Values for the individual fans and power supplies for these switches might display, but these parts cannot be replaced: the - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 165
the faulty slot or the switch for nonbladed switches. Recommended Action There is most likely a voltage hardware problem on the blade or motherboard of the switch. For the Brocade DCX, 24000 and 48000, replace the blade field-replaceable unit (FRU). For the Brocade 3900 replace the motherboard FRU - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 166
. Refer to the Brocade 48000 Hardware Reference Manual for more information about chassisConfig modes and supported blades. Severity CRITICAL EM-1010 if it has powered down or not. Recommended Try reseating the blade. If this fails to correct the error, replace the blade. Action Severity CRITICAL - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 167
serious internal Fabric OS configuration or hardware problems on the switch. Recommended Action On Brocade DCX, 24000 and 48000, try reseating the indicated field-replaceable unit (FRU). If the message persists, reboot or power cycle the switch. Run the systemVerification command to verify that - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 168
problem was discovered when performing consistency checks during a cold boot. Recommended Action Monitor the switch contact your switch service provider. Severity executing a reboot, power cycle, or firmwareDownload control processor (CP) blade is operational and with standby firmware version (Pre - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 169
firmware on the standby to the version running on the active problems were encountered when the software problem. The FRU ID value is composed of a FRU type string and an optional number to identify the unit, slot, or port. Recommended Action If the message persists, reboot or power cycle the switch - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 170
, or completely screw in the upper thumbscrew for the FC4-48 port blade) if the field-replaceable unit (FRU) is intended for use. Refer to the appropriate hardware manual for instructions on inserting the switch blades. Severity ERROR EM-1033 Message , [EM-1033], - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 171
. Recommended Action Reseat the FRU card. If the message persists, reboot or power cycle the switch. Run the systemVerification command to verify that the switch does not have hardware problems. Refer to the Fabric OS Command Reference for more information on this command. If the message persists - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 172
Recommended If the message is isolated, monitor the error messages on the switch. If the message is associated Action with other messages, follow the sequence-number>,, WARNING, , Can't power on , its logical switch is shut down 114 Fabric OS Message Reference 53-1001157- - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 173
is indicating a predicted failure. If new_state is Down (not enough power), a newly inserted port blade was not powered on because there was not enough power available. Recommended The Brocade 24000 requires only a single power supply for a fully populated chassis; however, you Action should always - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 174
access to the field-replaceable unit (FRU) has become available again. Recommended The EM-1029 error can be a transitory error; if the problem resolves, the EM-1048 message is Action displayed. Severity INFO EM-1049 Message , [EM-1049], ,, INFO, , FRU - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 175
in the slot. Recommended Action Verify that the media can be run at the configured port speed. If the port media is extended long wavelength, move it to a port that can support the heat generated. Severity WARNING EM-1056 Message , [EM-1056], ,, WARNING, - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 176
your switch type. Action Severity CRITICAL EM-1060 Message , [EM-1060], ,, WARNING, , Stopping synchronization of the system due to blade incompatibility with software version on standby CP. Probable Cause Indicates a blade in the system is not supported - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 177
a blade in the system is not supported by the release on the standby control processor (CP). Recommended Action Remove all blades of blade. Action Severity CRITICAL EM-1064 Message , [EM-1064], ,, CRITICAL, , Blade: is being powered off (based - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 178
power off the problem blade when such a condition occurred. Recommended Contact support. Action Severity CRITICAL EM-1065 Message , [EM-1065], ,, CRITICAL, , SSAS Virtualization Services or Storage Application Services (SAS) firmware has been upgraded - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 179
problems on the switch. Recommended Reboot or power cycle the switch. If the message persists, collect switch information using the Action supportsave command, and contact your switch service > is being powered on. Probable Cause Indicates a blade is being intentionally powered on. Recommended No - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 180
FRU. On nonbladed switches, reboot or power cycle the switch. If the problem persists: • Run the systemverification command to verify that the switch does not have hardware problems. Refer to theFabric OS Reference Manual for more information on this command. • On bladed systems, replace the - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 181
Action Discontinue the firmware download, identify the downlevel switch or switches that do not support the Coordinated HotCode protocol, and upgrade the downlevel switches. Then, restart the firmware download on this switch. Note that upgrading a downlevel Brocade switch in a mixed interop - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 182
domain id>. Probable Cause Indicates that during the Coordinated HotCode protocol, a switch in the fabric has rejected the resume message which prevented the protocol from completing. Any data traffic disruption observed during the firmware download may have been due to the rejected resume message - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 183
EVMD System Messages 19 EVMD-1001 Message , [EVMD-1001], ,, WARNING, , Event could not be sent to remote proxy. = Probable Cause Indicates the event could not be sent to remote proxy. This could happen if the remote proxy - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 184
19 EVMD-1001 126 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 185
Cause Indicates that an internal link service (ILS) information unit of invalid size has been received. The neighbor switch has sent a payload with an invalid size. Recommended Action Investigate the neighbor switch for problems. Run the errShow command on the neighbor switch to view the error log - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 186
switch service provider. Severity WARNING FABR-1004 Message , [FABR-1004], ,, WARNING, , port: - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 187
automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING FABR-1007 Message , [FABR-1007], information unit. This message is rare and usually indicates a problem with the Fabric OS. Recommended Action In case of severe - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 188
message is rare and usually indicates a problem with the Fabric OS. Recommended If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity WARNING FABR-1011 Message - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 189
not enough memory in the switch for the fabric module to allocate. This message is rare and usually indicates a problem with the Fabric OS. switch service provider. Severity CRITICAL FABR-1014 Message , [FABR-1014], , FFDC, ERROR, , Port - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 190
is enabled. Probable Cause Indicates that FICON mode is enabled on the switch through a user interface command. Recommended No action is required. Action , , Critical fabric size () exceeds supported configuration (). 132 Fabric OS Message - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 191
licensed limit. Contact your switch provider to obtain a full fabric license. Severity CRITICAL FABR-1022 Message , [FABR-1022], , FFDC, CRITICAL, , Fabric size () exceeds supported configuration (). Fabric limit timer - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 192
changed to within the licensed limit. Contact your switch provider to obtain a full fabric license. Severity CRITICAL FABR-1023 Message , [FABR-1023], ,, INFO, , Fabric size is within supported configuration (). Fabric limit timer ( - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 193
modes, the buffer credits are fixed, based on the port configuration information. In this mode, the port exceeded. Probable Cause Indicates the fabric exhausted the maximum number of retries sending internal link service WARNING, , Remote switch with domain ID - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 194
Trunk Area. You must manually enable the port or the port remains disabled forever. Refer to the Admin Guide for more information. port. Persistently disabling port . Probable Cause Indicates the specified port is being disabled because when the port on a Switch - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 195
is being disabled because when the port attempts to go online, the Switch finds that Trunk Area enabled is incompatible with port configuration such as long distance, port mirror, fast write or EX_port. Recommended Check the port configuration to disable long distance, port mirror, fast write or - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 196
firmware to a VF-capable firmware. Severity ERROR FABR-1045 Message Probable Cause , [FABR-1045], , ERROR, , Detected Base Switch conflict with remote (not neighbor) switch (domain ), BS . No local E-ports - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 197
that the remote switch has a Base Switch attribute conflict with the local switch. All the E_ports directly connected to the conflicting switch are disabled. Recommended Make sure that all the switches in the fabric have the same Base Switch attribute or upgrade the Action switch firmware to a VF - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 198
20 FABR-1046 140 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 199
Indicates that an internal problem has been detected by the software. This is usually an internal Fabric OS problem or file corruption. Recommended Action Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware. Severity WARNING FABS - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 200
media state to blade driver Recommended Action If the message is isolated, monitor the error messages on the switch. If the error problem or file corruption. Recommended Action Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 201
unknown event type. This is usually an internal Fabric OS problem or file corruption. Recommended Action Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware. Severity WARNING FABS-1011 Message Probable Cause , [FABS-1011 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 202
to the requested state. This is usually an internal Fabric OS problem. Recommended Action Reboot or power-cycle the CP or system. If the message persists, run the firmwareDownload command to update the firmware. Severity ERROR FABS-1013 Message , [FABS-1013], - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 203
enabled. This is usually an internal Fabric OS problem. Recommended Action Try removing and reinserting the FRU. Reboot or power-cycle the CP or system. If the message persists, run the firmwareDownload command to update the firmware. Severity ERROR Fabric OS Message Reference 145 53-1001157 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 204
21 FABS-1015 146 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 205
Action The problem can be corrected by changing the version of firmware on the CP or AP blades. The firmware version on the CP blade can be changed using the firmwareDownload command. Refer to the release notes to determine whether a non-disruptive firmwareDownload is supported between the - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 206
22 FBC-1001 148 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 207
sequence-number>, FFDC, ERROR, , of GE failed. Please retry the command. Data: inst= st=< Indicates that a FIPS failure has occured and requires faulting the blade or switch. Recommended Retry the command again. Action Severity ERROR FCIP- - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 208
-1004 Message , [FCIP-1004], , INFO, CFG, , Tape Read Pipelining is being disabled slot () port () tunnel (). Probable Cause Indicates that the FOS version on the remote end of the tunnel does - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 209
allocate new memory for an information unit (IU). Recommended A nonbladed switch will automatically reboot. For a bladed switch, the active CP blade will Action automatically fail over and the standby CP will become the active CP. Severity CRITICAL Fabric OS Message Reference 151 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 210
24 FCMC-1001 152 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 211
firmware on the device controller on the specified port has a defect. Action Check with the device vendor for a firmware supported in this port type Probable Cause Indicates that private devices will not respond to the switch port login (PLOGI) during probing. Recommended Action The Brocade - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 212
25 FCPD-1003 154 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 213
". This function creates a Fibre Channel driver instance. The failed function call is "kmalloc_wrapper failed". This function call is for kernel memory allocation. Recommended A nonbladed switch will automatically reboot. For a bladed switch, the active CP blade will Action automatically fail over - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 214
26 FCPH-1002 156 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 215
action is required. Action Severity INFO FCR-1003 Message , [FCR-1003], ,, INFO, ,FC router physical devices newly exported at port . Probable Cause Indicates that one or more physical devices have been newly exported through the specified - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 216
. Action Severity INFO FCR-1006 Message , [FCR-1006], ,, INFO, , FC router LSAN zone device added at port . Probable Cause Indicates that a device is added to a logical storage area network (LSAN) zone in the edge fabric. Recommended No - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 217
required. Action Severity INFO FCR-1009 Message , [FCR-1009], ,, INFO, , FC router LSAN zone enabled at port : . Probable Cause Indicates that a logical storage area network (LSAN) zone was enabled in the edge fabric attached to - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 218
id () fabric ID . Probable Cause Indicates that a fabric is no longer accessible through the backbone fabric. This may be caused by a link or switch failure. Recommended No action is required. Action Severity INFO 160 Fabric OS Message Reference 53 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 219
. Use the fcrProxyDevShow command to view how many proxy devices are created in the fabric with the port resource problem. LSAN zones are removed using standard zoning commands such as zoneShow, zoneRemove, zoneDelete, cfgDelete, and cfgDisable in the edge fabric. Proxy devices can be removed - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 220
of translate domains). You can also limit the number of proxy devices for a translate domain (which limits the number of translate domain ports required) by limiting the devices specified in logical storage area network (LSAN) zones. Severity WARNING 162 Fabric OS Message Reference 53-1001157 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 221
It is unlikely that WWN conflicts will occur as a result of pool rollover unless the switch is deployed in a very large MetaSAN environment with large number of logical storage area >,, INFO, , In slot port WWN roll over. Fabric OS Message Reference 163 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 222
Cause Indicates that the port world wide name (WWN) pool has rolled over in the specified slot, and WWN entries detected to not be in use are reused as needed. Recommended Action It is unlikely that WWN conflicts will occur as a result of pool rollover unless the switch is deployed in a very - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 223
is required. Action Severity INFO FCR-1033 Message , [FCR-1033], ,, INFO, , Edge fabric disabled security on port in fabric . Probable Cause Indicates that Secure mode was turned off in the edge fabric. Recommended No action is - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 224
27 FCR-1034 FCR-1034 Message , [FCR-1034], ,, INFO, , LSAN zone added in backbone fabric. Probable Cause Indicates that a new logical storage area network (LSAN) zone was added to the backbone fabric. Recommended No action is required. Action Severity - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 225
: . Probable Cause Indicates that the number of cfg/zone/alias entries created in a local fabric is greater than the local switch's zone database limitations. Recommended Remove excess cfg/zone/alias entries so that the number of logical storage area network (LSAN) Action zones - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 226
type was not set. Recommended Action Setting port credits failed. Execute the portEnable command. If the problem persists try rebooting the switch. If the message persists, collect switch information using the supportShow command, and contact your switch service provider. Severity ERROR FCR-1049 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 227
and portDisable commands to enable and disable the port. If the problem persists contact your switch service provider. Severity ERROR FCR-1053 Message , [FCR-1053], ,, WARNING, , Port was disabled, . Probable Cause Indicates - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 228
-to-edge routing is not needed. Otherwise replace the switch with Action one that supports backbone to edge routing. Severity INFO FCR-1057 Message on the local switch. Run the appropriate configuration command to modify the switch or port parameters on the remote switch. Severity WARNING - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 229
fabric was built on the specified port. Recommended No action is required. Action Severity INFO FCR-1062 Message , [FCR-1062], ,, INFO, , Port disabled, system only supports EX/VEX_ports. Fabric OS Message Reference - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 230
of supported EX_ports or VEX_ports was exceeded. To enable the specified port, disable any other operational port then re-enable the port. Recommended name>, Fabric on port was assigned two different fabric IDs. Probable Cause Indicates that another port on the switch is connected to - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 231
port number> by entries; max entries: . Probable Cause Indicates that the total number of zone configurations created in the connected fabric exceeds the maximum number supported by the Fibre Channel. The limit includes both active the FC Routing service is disabled by - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 232
with the fcrState set to 1 (enabled). Note that the FC Routing service is disabled by the factory. Recommended No action is required. Action Severity INFO, , Port is changed from FCR port to non FCR port. Probable Cause Indicates that the port is no longer an EX_Port - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 233
than characters in the edge fabric connected to port . Probable Cause Indicates that the zone name configuration size created in the connected fabric exceeds the maximum supported by the FC Router. This size is equal to the total number of characters used by all the - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 234
Port rejected fabric binding request/check from the M-Model switch; . Probable Cause Indicates that an M-Model edge switch attempted to either activate or check the fabric binding. This port LSAN name exceeds the limit of 64 characters. Recommended Please change the name - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 235
the domain . Probable Cause During the Coordinated HotCode protocol, a switch in the fabric did not accept the pause message which prevented the protocol from completing. Any data traffic disruption observed during the firmware download may have been due to this issue. Recommended Action - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 236
,, ERROR, , HA sync lost as remote CP does not support Condor2 based EX_ports. Indicates that the remote control processor (CP) has older firmware, which does not support Condor-based EX_ port. This is causing the loss of the high-availability (HA) synchronization. 178 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 237
27 FCR-1087 Recommended Disable Condor2-based EX_ports or upgrade the remote CP. Action Severity ERROR FCR-1087 Message , [FCR-1087], ,, ERROR, , ExPort connects to fabric < - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 238
27 FCR-1089 180 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 239
: This is a 1 byte hexidecimal value that represents the domain of the switch that the FICON Channel is directly connected to. HP - Host Port number: This is a 1 byte hexidecimal value that represents the switch port of the switch that the FICON Channel is directly connected to. DD - Device Domain - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 240
Probable Cause Indicates the configuration was changed manually. Recommended No action is required. Action Severity , , FICON GEPort < 0 or 1 - GE port number> TID Feature Change failed Xrc - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 241
to read the sense data. Recommended If there was a job failure associated with this event, please contact your vendor's customer support Action for assistance. Severity INFO FICN-1010 Message , [FICN-1010], ,, INFO, , DevDiskEgr:Device level exception - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 242
an LBY frame. Recommended If there was a job or IO failure associated with this event, please contact your vendor's customer Action support for assistance. Severity INFO FICN-1014 Message , [FICN-1014], ,, INFO, , DevEgr:Device level exception flag found - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 243
with an invalid LRC. This indicates data corruption between the emulation processing components. Recommended Please contact your vendor's customer support for assistance. Action Severity ERROR FICN-1016 Message , [FICN-1016], ,, INFO, , DevIng:Received - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 244
LRJ frame for a sequence from the device. Recommended If there was a job failure associated with this event, contact your vendor's customer support for Action assistance. Severity ERROR FICN-1020 Message , [FICN-1020], ,, ERROR, , DevTapeEgr:FICON Cancel - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 245
Indicates the FICON channel issued a Selective Reset for a device that was active in emulation. Recommended If there was an unexpected job failure associated with this event, contact your vendor's customer Action support for assistance. Severity ERROR FICN-1023 Message , [FICN-1023 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 246
that included the Device Level Exception>. Probable Cause Indicates an active emulation device delivered a Device Level Exception frame to the emulation associated with this event, contact your vendor's Action customer support for assistance. Severity ERROR FICN-1029 Message Probable Cause - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 247
associated with this event, contact your vendor's Action customer support for assistance. Severity ERROR FICN-1030 Message , [FICN HostDiskIng:FICON Purge received:Path=. Probable Cause Indicates an active disk emulation device received a FICON Purge Path from the channel - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 248
peer. This indicates that the channel side noted corruption from the device/CU side processing. Recommended Contact your vendor's customer support for assistance. Action Severity ERROR FICN-1035 Message , [FICN-1035], ,, WARNING, , HostIng:FICON System - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 249
a FICON Control Unit. Recommended Contact your vendor's customer support for assistance. Action Severity ERROR FICN-1040 Message , 0x. Probable Cause Indicates an active disk emulation device received a FICON Purge Path from the channel. - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 250
the CU has lost the logical path to the LPAR. Recommended If this was an unexpected event, contact your vendor's customer support for assistance. Action Severity ERROR FICN-1042 Message , [FICN-1042], ,, WARNING, , HostTapeIng:FICON Cancel received Path - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 251
FICON channel. This is performed during the path recovery. Recommended If this was an unexpected event, contact your vendor's customer support for assistance. Action Severity WARNING FICN-1046 Message , [FICN-1046], ,, WARNING, , HostTapeIng:LRJ received - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 252
it no longer has an established path to its peer. Recommended This is an unexpected event; contact your vendor's customer support for assistance. Action Severity WARNING FICN-1050 Message , [FICN-1050], ,, WARNING, , ProcessEgrTirData:Lost Logical Path - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 253
to break an XRC session with the extended DASD device. Recommended If this was an unexpected event, contact your vendor's customer support for assistance. Action Severity INFO FICN-1053 Message , [FICN-1053], ,, INFO, , XRC Withdraw From Session: SessID - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 254
to break an XRC session with the extended DASD device. Recommended If this was an unexpected event, contact your vendor's customer support for assistance. Action Severity WARNING FICN-1056 Message , [FICN-1056], ,, ERROR, , FICON Emulation Error Error Code - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 255
=0x. Probable Cause Indicates an abort operation has been received from the local FC interface for an active emulation exchange. Recommended This is an unexpected event, contact your vendor's customer support for assistance. Action Fabric OS Message Reference 197 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 256
interface for an active emulation exchange. Recommended This is an unexpected event, contact your vendor's customer support for assistance. Action Number> VEPort= from SID=0x to DID=0x. Probable Cause Indicates an abort operation has - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 257
the maximum number of emulation devices are already in use Action or there is an internal memory leak, contact your vendor's customer support for assistance. Severity WARNING FICN-1067 Message , [FICN-1067], ,, ERROR, , Ingress Abort:Oxid=0x - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 258
device or error status (including Unit Check 0x02) is received from an active emulation device. Recommended The end of tape is a normal event during pipelining messages with this event, please contact your vendor's customer support for assistance. Severity INFO FICN-1071 Message , [ - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 259
28 FICN-1074 Recommended No action is required. Action Severity INFO FICN-1074 Message , [FICN-1074], ,, INFO, , HostTapeIngr:WriteReport:Path=:Emuls=0x:Cmds=0x - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 260
28 FICN-1077 Recommended No action is required. Action Severity INFO FICN-1077 Message , [FICN-1077], ,, INFO, , DevTapeEgr:Unloaded:Path=:states=0x:cmds=0x: - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 261
VEPortNumber> Domain=0x Port=0x. Probable Cause Indicates an attached port which had a FICON emulated path established has logged out from the switch. Recommended This may be an unexpected event, contact your vendor's customer support for assistance. Action Severity - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 262
= Domain=0x Port=0x. Probable Cause Indicates an attached port with the established FICON emulated path has logged out from the switch. Recommended This may be an unexpected event, contact your vendor's customer support for assistance. Action Severity - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 263
The error variable is an internal error number. Recommended Action If this is a bladed switch, execute the haFailover command. If the problem persists, or if this is a nonbladed switch, download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Command Reference for - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 264
the Fabric OS Administrator's Guide for information on core PID mode and the Fabric OS Command Reference Manual for information on these commands the fibre connectivity control unit port (FICON-CUP) daemon failed. Recommended Download a new firmware version using the firmwareDownload command. - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 265
problem. Recommended Action If the message persists, check the memory usage on the switch command and contact your switch service provider. Severity WARNING FICU ports. Recommended Use the perfDelFilterMonitor command to delete the filter-based performance monitors used on all Action ports - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 266
Server mode (fmsMode) was not enabled because the specified port which has an address conflict with the CUP management port is in use. Recommended Use the portDisable command to disable the specified port to avoid the port address conflict. Action Severity WARNING 208 Fabric OS Message - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 267
WARNING, , exchange overlapped, pid= Probable Cause Indicates that the FC kernel driver has timed out the exchange while the application is still active. When the FC kernel driver reuses the exchange, the application will overlap. This happens on a timed-out exchange; it - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 268
30 FKLB-1001 210 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 269
sequence-number>, FFDC, WARNING, , Unknown LSR type: port , type Probable Cause Indicates that the link Probable Cause Indicates that the LSU size exceeds what the system can support. Recommended Reduce the number of switches in the fabric or reduce the - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 270
31 FLOD-1006 Probable Cause Indicates that the received LSR contained an invalid domain number. Recommended No action is required; the LSR is discarded. Action Severity WARNING FLOD-1006 Message , [FLOD-1006], ,, WARNING, , Transmitting invalid domain ID: - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 271
Chapter FSPF System Messages 32 FSPF-1001 Message , [FSPF-1001], ,, ERROR, , Input Port out of range Probable Cause Indicates that the specified input port number is out of range; it does not exist on the switch. Recommended No action is - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 272
port. The section ID is used to identify a set of switches that share an identical topology database. The section ID is implemented inside the protocol. The error message itself will indicate the mismatched section ID. It should be set to 0 for a nonhierarchical fabric. Brocade switches support - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 273
persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING FSS-1002 Message , [FSS-1002], ,, WARNING, , Component () sending too - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 274
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR FSS-1005 Message , [FSS-1005], ,, WARNING, , FSS read failure Probable Cause - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 275
the active CP and standby CP (interface eth1) by issuing net commands such as ifconfig eth1 (as root) or run supportShow/supportSave to validate the network configuration; then try to restore the synchronization by issuing the haSyncStart command. If the problem persists, contact your switch service - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 276
33 FSS-1011 FSS-1011 Message , [FSS-1011], ,, INFO, , FSS Info: . Probable Cause Indicates that an error has occurred. Recommended No action is required. Action Severity INFO 218 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 277
problem. If the problem persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING FSSM-1004 Message , [FSSM-1004], ,, INFO, , Incompatible software - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 278
CP in a dual CP system are running firmware that are incompatible with each other. If the active CP fails, the failover will be disruptive. In a switch system, this message is logged when a firmware upgrade/downgrade was invoked. The new firmware version is not compatiable with the current running - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 279
Value> . Probable Cause Indicates that the internal temperature of the switch has changed. Recommended Action No action is required. Respond to this message range of the switch. Refer to the hardware reference manual for the environmental temperature range of your switch. Severity WARNING - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 280
> . Probable Cause Indicates that the internal temperature of the switch has changed from a value outside of the acceptable range to a that the speed of the fan has changed. Fan problems typically contribute to temperature problems. Recommended Action No action is required. Respond to this - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 281
it is seated correctly in the chassis. Run the psShow command to view the status of the power supply. If the power supply continues to be a problem, replace the faulty power supply. Severity INFO FW-1010 Message Probable Cause , [FW-1010], ,, WARNING, - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 282
supply correctly and that it is correctly seated in the Action chassis. If the problem persists, replace the faulty power supply. Severity WARNING FW-1011 Message , [FW-1011], ,, INFO, , , is above high boundary(High=, Low= - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 283
, , value has changed(High=, Low=). Current value is . Probable Cause Indicates that the receive power value of the small form-factor pluggable (SFP) has changed. The receive performance area measures the amount of incoming laser to help you - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 284
name>, , is below low boundary(High=, Low=). Current value is . Probable Cause Indicates that the receive power value of the small form-factor pluggable (SFP) has fallen below the low boundary. The receive performance area measures the amount of incoming - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 285
Label>, is below low boundary(High=, Low=). Current value is . Probable Cause Indicates that the transmit power value of the small form-factor pluggable (SFP) has fallen below the low boundary. The transmit performance area measures the amount of outgoing laser - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 286
is between high and low boundaries(High=, Low=). Current value is . Probable Cause Indicates that the transmit power value of the small form-factor pluggable (SFP) has changed from a value outside of the acceptable range to a value within the acceptable range - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 287
35 FW-1048 Probable Cause Indicates that the value of the small form-factor pluggable (SFP) voltage has risen above the high boundary. The supplied current of the SFP transceiver is outside of the normal range, indicating possible hardware failure. Recommended If the current rises above the high - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 288
35 FW-1051 FW-1051 Message , [FW-1051], ,, WARNING, , , is above high boundary(High=, Low=). Current value is . Probable Cause Indicates that the value of the small form-factor pluggable (SFP) voltage has risen - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 289
SFP failures also cause E_Ports to go down. E_Port downs might be caused by transient errors. A low number of E_Port failures means that the switch is functioning normally. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 290
fabric reconfiguration might be a transient error and might not require troubleshooting. Severity INFO FW-1118 Message , [FW-1118], < boundary. The following occurrences can cause a fabric reconfiguration: • Two switches with the same domain ID have connected to one another. • Two - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 291
changes has changed. Domain ID changes occur when there is a conflict of domain IDs in a single fabric and the principal switch has to assign another domain ID to the switch. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 292
occur due to: • Zone conflicts. • Domain conflicts. • Segmentation of the principal link between two switches. • Incompatible link parameters. During E_Port initialization, ports exchange link parameters. Rarely, incompatible parameters result in segmentation. Recommended No action is required - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 293
occur due to: • Zone conflicts. • Domain conflicts. • Segmentation of the principal link between two switches. • Incompatible link parameters. During E_Port initialization, ports exchange link parameters. Rarely, incompatible parameters result in segmentation. A low number of segmentation errors - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 294
35 FW-1129 • Zone conflicts. • Domain conflicts. • Segmentation of the principal link between two switches. • Incompatible link parameters. During E_Port initialization, ports exchange link parameters. Rarely, incompatible parameters result in segmentation. Recommended No action is required. - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 295
Current value is . Probable Cause Indicates that the number of fabric logins has fallen below the low boundary. Fabric logins occur when a port or device initializes with the fabric. The event is called a fabric login or FLOGI. A low number of fabric logins means that the fabric is - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 296
number of fabric logins has changed from a value outside of the acceptable range to a value within the acceptable range. Fabric logins occur when a port or device initializes with the fabric. The event is called a fabric login or FLOGI. Recommended No action is required. Respond to this message as - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 297
changes means that the switch is functioning normally. Recommended , , , , value problems can cause link loss errors. Link loss errors frequently occur due to a loss of synchronization. Check for concurrent loss of synchronization errors and, if applicable, troubleshoot - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 298
failures that the port experiences has fallen problems can cause link loss errors. Link loss errors frequently occur due to a loss of synchronization. Check for concurrent loss of synchronization errors and, if applicable, troubleshoot them. A low number of link loss errors means that the switch - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 299
. If you continue to experience synchronization loss errors, troubleshoot your host bus adaptor (HBA) and contact your switch service provider. Severity INFO FW-1165 Message , [FW-1165], ,, INFO, , , , is below low boundary(High= - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 300
troubleshoot your host bus adaptor (HBA) and contact your switch service provider. Severity WARNING FW-1167 Message , [FW-1167], ,, INFO, , - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 301
the switch is functioning normally. Severity INFO FW-1170 Message , [FW-1170], ,, WARNING, , , port experiences has changed. Occasional protocol errors occur due to software glitches. Persistent protocol errors occur due to hardware problems - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 302
number of protocol errors that the port experiences has fallen below the low boundary. Occasional protocol errors occur due to software glitches. Persistent protocol errors occur due to hardware problems. A low number of protocol errors means that the switch is functioning normally. Recommended No - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 303
that the number of invalid words that the port experiences has changed. Invalid words usually indicate a hardware problem with an small form-factor pluggable (SFP a hardware problem with an small form-factor pluggable (SFP) or cable. A low number of invalid words means that the switch is functioning - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 304
Probable Cause Indicates that the number of invalid words that the port experiences has changed from a value outside of the acceptable range to a value within the acceptable range. Invalid words usually indicate a hardware problem with an small form-factor pluggable (SFP) or cable. Recommended No - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 305
High=, Low=). Current value is . Probable Cause Indicates that the percentage of incoming traffic that the port experiences has changed. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 306
(High=, Low=). Current value is . Probable Cause Indicates that the percentage of incoming traffic that the port experiences has risen above the high boundary. Recommended No action is required. Respond to this message as is appropriate to the particular policy - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 307
has gone offline, has come online, is testing, is faulty, has become an E_Port, has become an F_Port, has segmented, or has become a trunk port. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 308
, is testing, is faulty, has become an E_Port, has become an F_Port, has segmented, or has become a trunk port. A low number of port state changes means that the switch is functioning normally. Recommended No action is required. Respond to this message as is appropriate to the particular policy of - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 309
Cause Indicates that the number of link resets that the port experiences has risen above the high boundary. Link resets occur due to link timeout errors that indicate no frame activity at all. Both physical and hardware problems can cause link resets to increase. Recommended Check both ends - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 310
number of link resets that the port experiences has changed from a value outside of the acceptable range to a value within the acceptable range. Link resets occur due to link timeout errors that indicate no frame activity at all. Both physical and hardware problems can cause link resets to increase - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 311
fluctuations, and aging equipment. You should set your high boundaries to five- or six-digit figures, as only large numbers of messages indicate a problem in this area. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 312
35 FW-1241 Severity INFO FW-1241 Message , [FW-1241], ,, INFO, , , is below low boundary(High=, Low=). Current value is . Probable Cause Indicates that the number of end-to-end (EE) cyclic redundancy check ( - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 313
=, Low=). Current value is . Probable Cause Indicates that the number of end-to-end (EE) word frames that the switch receives has changed. Receive performance messages appear due to the number of word frames that travel from the configured S_ID to the D_ID pair - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 314
Probable Cause Indicates that the number of end-to-end (EE) word frames that the switch transmits has changed. Transmit performance messages appear due to the number of word frames that value>, Low=). Current value is . 256 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 315
that the number of end-to-end (EE) word frames that the switch transmits has changed from a value outside of the acceptable range to a Indicates that the number of frame types or commands that the port receives has changed. The port has received small computer system interface (SCSI) Read, SCSI Write - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 316
the number of frame types or commands that the port receives has risen above the high boundary. The port has received a small computer system interface (SCSI) IP) addresses that are authorized to establish Telnet connections to switches in the fabric. Recommended Action Run the errShow command to - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 317
an unauthorized IP address. The TELNET_POLICY contains a list of internet protocol (IP) addresses that are authorized to establish Telnet connections to switches in the fabric. Recommended Action Run the errShow command to determine the IP address that sent the request. Responses to security-class - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 318
unauthorized IP address. The HTTP_POLICY contains a list of internet protocol (IP) addresses that are authorized to establish browser connections to the switches in the fabric. Recommended Action Run the errShow command to determine the IP address that sent the request. Responses to security-class - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 319
network management protocol policy (SNMP_POLICY) contains a list of internet protocol (IP) addresses that are authorized to establish API connections to switches in the fabric. Recommended Action Run the errShow command to determine the IP address that sent the request. Responses to security-class - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 320
network management protocol policy (SNMP_POLICY) contains a list of internet protocol (IP) addresses that are authorized to establish API connections to switches in the fabric. Recommended Action Run the errShow command to determine the IP address that sent the request. Responses to security-class - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 321
35 FW-1309 FW-1309 Message , [FW-1309], ,, INFO, , , is below low boundary(High=, Low=). Current value is . Probable Cause Indicates that the number of simple network management protocol read (RSNMP) violations - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 322
35 FW-1312 FW-1312 Message , [FW-1312], ,, INFO, , , value has changed(High=, Low=). Current value is . Probable Cause Indicates that the number of simple network management protocol write (WSNMP) violations - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 323
SES violations indicate that a small computer system interface (SCSI) Enclosure Services (SES) request has been received from an unauthorized world wide name (WWN). The SES_POLICY contains a list of WWNs of device ports that are allowed to access the SES Server functionality. Recommended No - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 324
violations indicate that a small computer system interface (SCSI) Enclosure Services (SES) request has been received from an unauthorized world wide name (WWN). The MS_POLICY contains a list of WWNs of device ports that are allowed to access the Management Server functionality. Recommended Action - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 325
that an MS access request has been received from an unauthorized world wide name (WWN). The MS_POLICY contains a list of WWNs of device ports that are allowed to access the Management Server functionality. Recommended Action Run the errShow command to determine the WWN of the device that sent the - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 326
has fallen below the low boundary. Serial violations indicate that an unauthorized serial port request has been received. The SERIAL_POLICY contains a list of switch world wide names (WWNs) for which serial port access is enabled. Recommended No action is required. Action Severity INFO FW-1326 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 327
a value within the acceptable range. Serial violations indicate that an unauthorized serial port request has been received. The SERIAL_POLICY contains a list of switch world wide names (WWNs) for which serial port access is enabled. Recommended No action is required. Action Severity INFO FW-1328 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 328
within the acceptable range. Front panel violations indicate that an unauthorized front panel request has been received. The FRONTPANEL_POLICY contains a list of switch world wide names (WWNs) for which front panel access is enabled. Recommended No action is required. Action Severity INFO FW-1332 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 329
between high and low boundaries(High=, Low=). Current value is . Probable Cause Indicates that the number of switch connection control policy (SCC) violations has changed from a value outside of the acceptable range to a value within the acceptable range. SCC - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 330
performing FLOGI is done through the name server. Recommended Action Run the errShow command to determine the device WWN, switch WWN, and switch port. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies and policies. Severity - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 331
device tried to join the fabric. The DCC_POLICY allows for the specification of rules for binding device ports (typically host bus adaptor (HBA) ports) to specific switch ports. DCC policies ensure that whenever a device performs a fabric login (FLOGI) request that the world wide name (WWN - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 332
has been received from the primary fabric configuration server (FCS). When the primary FCS downloads a new configuration to other switches in the fabric, the packet is tagged with a timestamp. The receiving switch compares this timestamp to its current time. If the difference is too great, it - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 333
from the primary world wide name (WWN). When the primary fabric configuration server (FCS) downloads a new configuration to other switches in the fabric, the packet is tagged with a timestamp. The receiving switch compares this timestamp to its current time. If the difference is too great, it - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 334
-signature violations indicate that a packet with an invalid signature has been received from the primary fabric configuration server (FCS). When the FCS downloads a new configuration to the other switches in the fabric, the packet is signed using the private key of the primary FCS. The receiving - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 335
violations indicate that a packet with an invalid signature has been received from the primary fabric configuration server (FCS). When the primary FCS downloads a new configuration to the other switches in the fabric, the packet is signed using the private key of the primary FCS. The receiving - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 336
in the fabric, it first sends its certificate to all the switches in the fabric. The receiving switch has to verify that the sender is the primary FCS switch and its certificate is signed by the Root CA recognized by the receiving switch. This counter keeps track of the number of packets received - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 337
the low boundary. Authentication failures can occur for many reasons. The switch on the other side might not support the protocol, have an invalid certificate, not be signed properly or send unexpected packets. The port where authentication fails is segmented. This counter keeps track of the number - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 338
the acceptable range. Authentication failures can occur for many reasons. The switch on the other side might not support the protocol, have an invalid certificate, not be signed properly or send unexpected packets. The port where authentication fails is segmented. This counter keeps track of the - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 339
value is . Probable Cause Indicates that the number of switch link authentication protocol (SLAP) faulty packets has risen above the high . Probable Cause Indicates that the number of time service (TS) out-of-sync violations has changed. Recommended Responses to - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 340
Current value is . Probable Cause Indicates that the number of time service (TS) out-of-sync violations has changed from a value outside of the acceptable fabric, but it still has the WWN of the last primary FCS switch, it increments this counter and resets the WWN of the primary FCS - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 341
finds that there are no FCSs in the fabric, but it still has the WWN of the last primary FCS switch, it increments this counter and resets the WWN of the primary FCS to all zeroes. Recommended Responses to security-class messages depend on user policies. - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 342
loses contact with the primary fabric configuration server (FCS) switch. When the primary FCS switch in the fabric sends its certificate to a switch, the receiving switch saves the world wide name (WWN) of that primary FCS switch. If a secure switch finds that there are no FCSs in the fabric, but - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 343
tracks how many times commands allowed only on the primary fabric configuration server (FCS) switch have been executed on a non-primary FCS switch. There are many commands that can be executed only on the primary FCS switch as well as one security command that can be executed only on a backup FCS - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 344
tracks how many times commands allowed only on the primary fabric configuration server (FCS) switch have been executed on a non-primary FCS switch. There are many commands that can be executed only on the primary FCS switch as well as one security command that can be executed only on a backup FCS - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 345
Indicates that the flash usage percentage has changed. Flash increases and decreases slightly with normal operation of the switch. Excessive permanent increases can lead to future problems. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 346
slightly with normal operation of the switch. Excessive permanent increases can lead to future problems. Recommended No action is required. , Switch status change contributing factor Power supply: bad, absent. Indicates that the switch status is not - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 347
Severity WARNING FW-1427 Message , [FW-1427], ,, WARNING, , Switch status change contributing factor Power supply: bad. Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of faulty - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 348
35 FW-1430 FW-1430 Message , [FW-1430], ,, WARNING, , Switch status change contributing factor . Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of faulty temperature sensors is greater - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 349
same level of firmware to both CPs. Replace any faulty CPs. If you reset the micro-switch (the latch on the CP blade) on the active CP before the heartbeat was up on a power cycle, and the CPs came up non-redundant, then you should reboot the CPs again to clear the problem. Severity WARNING FW - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 350
FW-1437 Message , [FW-1437], ,, WARNING, , Switch status change contributing factor faulty ports: . (Ports . Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 351
that the state of the specified field-replaceable unit (FRU) has changed to "inserted". This means that an FRU is inserted but not powered on. Recommended No action is required. Verify that the event was planned. Action Severity INFO FW-1442 Message , [FW-1442], - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 352
default values when an AP blade is or has been present are: 2 out of service indicates switch status is DOWN, 1 out of service indicates switch status is MARGINAL Recommended Action To maintain full (2X) redundancy and proper monitoring by Fabric Watch, 4 active power supplies should be supplied - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 353
: Port disabled. Probable Cause Link failures indicates that the specified port is now disabled because the link on this port had Occasionally, these errors occur due to software glitches. Persistent errors occur due to hardware problems. Recommended Check for concurrent loss of - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 354
35 FW-1510 296 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 355
"critical", "major", or "minor". The active CP will continue to function normally, but CP blade by ejecting the card and reseating it. If the problem persists action or an error. The switch reboot can be initiated by the this message are hardware errors, software errors, compact flash errors, or - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 356
:EM • Reboot:WebTool • Fastboot:WebTool • Software Fault:Software Watchdog • Software Fault:Kernel Panic • Software Fault:ASSERT • Reboot:SNMP • Fastboot:SNMP , ,EMAC controller for Active CP is BAD. Indicates that the local EMAC controller on the active control processor (CP) is BAD as - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 357
will take over and reset the active CP. The system will be non-redundant as the Action standby becomes the active CP. Severity CRITICAL HAM-1007 Message [HAM-1009], ,, CRITICAL, ,Need to MANUALLY REBOOT the system for recovery - auto-reboot is disabled. Probable Cause - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 358
36 HAM-1009 300 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 359
command and contact your switch service provider. Severity CRITICAL HAMK-1002 Message , [HAMK-1002], ,, INFO, , Heartbeat down. Probable Cause Indicates that the active control processor (CP) blade determined that the standby CP blade is down. This can - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 360
37 HAMK-1004 HAMK-1004 Message ,[HAMK-1004], ,, INFO, , Resetting standby CP (double reset may occur). Probable Cause Indicates that the standby control processor (CP) is being reset due to a loss of heartbeat. This message is typically seen when the - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 361
() is above threshold. Probable Cause Indicates that the blade voltage is above the threshold. Recommended Replace the faulty blade or switch (for nonbladed switches). Action Severity ERROR HIL-1102 Message , [HIL-1102], ,, ERROR - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 362
, and 4024, the entire switch must be replaced because these switches do not have field-replaceable units (FRUs). For the Brocade 3900, replace the motherboard FRU. For the Brocade 4100 , 4900, 7500, and AP7600, if the 12 volt level is faulty, replace one or both power supplies; if any other voltage - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 363
, and 4024, the entire switch must be replaced because these switches do not have field-replaceable units (FRUs). For the Brocade 3900, replace the motherboard FRU. For the Brocade 4100, 4900, 7500, and AP7600, if the 12 volt level is faulty, replace one or both power supplies; if any other voltage - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 364
of your switch. Refer to the hardware reference manual for your switch for the switches and is not applicable to the Brocade 24000 or 48000. Recommended Action For the Brocade 3900 replace the fan FRU. For the Brocade 3016, 3250 and 3850, the entire switch must be replaced because these switches - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 365
problem can quickly cause the switch to overheat. This message is specific to nonbladed switches and is not applicable to the Brocade 24000 or 48000. Recommended For the Brocade operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 366
-replaceable unit (FRU) has failed or has been removed. This message is often preceded by a low speed error message. This problem can cause the switch to overheat. Recommended Replace the affected fan FRU immediately. Action Severity WARNING HIL-1302 Message , [HIL-1302], - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 367
38 HIL-1305 Severity ERROR HIL-1305 Message , [HIL-1305], ,, ERROR, , One or two fans failed. Replace failed fan FRUs immediately. Probable Cause Indicates that multiple fan field-replaceable units (FRUs) have failed. This message is often preceded by a - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 368
have failed. This message is often preceded by a low fan speed message. Recommended Since the fans are not field replaceable, replace the switch if the temperature is high. Action Severity WARNING HIL-1311 Message , [HIL-1311], ,, INFO, , No fans are - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 369
-1501 Message Probable Cause , [HIL-1501], ,, WARNING, , Slot , high temperature (). Indicates that the temperature of this blade has risen above the warning threshold. Fabric OS Message Reference 311 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 370
and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. If the message persists, replace the blade. Severity CRITICAL HIL-1503 Message , [HIL-1503], , FFDC - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 371
. To help prevent future problems, make sure that all the fans are working properly. Make sure that the area is well-ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 372
. To help prevent future problems, make sure that all the fans are working properly. Make sure that the area is well-ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 373
not supplying power, fan speeds not available. Please ensure that the unit has power and the switch is on. Indicates that the power supply is not connected to a power source or it is not switched on or the unit is faulty. Applicable only to Brocade 5100. Fabric - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 374
cord is connected to the unit with a valid power source and then switch on the Action unit. If the problem persists, try reseating the unit. If the problem still persists replace the FRU. Severity WARNING HIL-1650 Message , [HIL-1650], , ERROR, , - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 375
HLO-1003], , FFDC, ERROR, , Invalid Hello received from port , Domain = , Remote Port =. Indicates that the HLO message received was invalid and the frame was dropped. The Brocade switch will not accept FSPF frames from the remote - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 376
an invalid HLO because either the domain or port number in the HLO message has an invalid value. This error can only occur when the Brocade switch is connected to a switch from another manufacturer. Recommended The HLO message of the remote switch must be compatible with the value specified in - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 377
Action Run the firmwareDownload command to reinstall the firmware to your switch. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity CRITICAL Fabric OS Message Reference 319 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 378
40 HMON-1001 320 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 379
>, [HTTP-1001], ,, INFO, , Switch PIDformat has changed to . Probable Cause Indicates that information on PID format, refer to the Fabric OS Administrator's Action Guide. Severity INFO HTTP-1002 Message , [HTTP-1002], - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 380
41 HTTP-1003 322 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 381
-name>, Slot , Port GE: Maximum attempts to restart failed. Disabling port. Probable Cause Indicates that the specified port has crashed unexpectedly and restarting attempts have failed. Recommended Power off and power on the blade using the slotPowerOff and slotPowerOn - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 382
42 IBD-1001 324 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 383
name>, iSCSI login sessions exceed the maximum limit at slot port ge Probable Cause Indicates that the iSCSI login sessions exceed the supported limit per port. Recommended Use another port to log in. Action Severity WARNING Fabric OS Message Reference 325 53-1001157 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 384
43 IBPD-1003 326 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 385
or power cycle the switch. Severity ERROR ICPD-1002 Message , [ICPD-1002], ,, ERROR, , Failed to initialize rc = . Probable Cause Indicates that an initialization of a module within the ICPD failed. Recommended Download a new firmware - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 386
ICPD-1006 Message , [ICPD-1006], ,, INFO, , iSCSI service is on the switch. Probable Cause Indicates the iSCSI service is enabled or disabled on the switch. Recommended No action is required. Action Severity INFO ICPD-1007 Message - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 387
Recommended No action is required. Action Severity INFO 44 ICPD-1008 Fabric OS Message Reference 329 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 388
44 ICPD-1008 330 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 389
> . Probable Cause Indicates that a change in the gateway IP address has occurred. If the source of the address change is manual, this means that the address change was initiated by a user. If the source of the address change is the dynamic host configuration protocol (DHCP - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 390
45 IPAD-1001 332 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 391
transfers; then run the supportSave command and contact your switch service provider. Severity WARNING IPS-1004 Message , [IPS-1004], ,, WARNING, , Port Config Mode Mismatch slot () port(ge): current mode is () Fabric OS Message - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 392
WARNING IPS-1005 Message , [IPS-1005], ,, WARNING, , Tunnel Authorization Failure for slot () port(ge) tunnel ID() reason () Probable Cause Indicates that tunnel setup failed because of an authorization failure from the - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 393
[ISCS-1000], ,, ERROR, , Slot Port GE crashed unexpectedly. Probable Cause Indicates the specified port has crashed. Recommended No action is required; the port will restart automatically. Action Severity ERROR Fabric OS Message Reference - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 394
47 ISCS-1000 336 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 395
name>, Start peering with external iSNS server slot/port /ge. Probable Cause Indicates that peering has started with the specified external internet storage name service (iSNS) server. Recommended No action is required. Action Severity INFO ISNS - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 396
Start re-register with external iSNS server slot/port /ge. Probable Cause Indicates that the re-register with the specified external internet storage name service (iSNS) server has started. Recommended No action is required. Action Severity INFO - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 397
48 ISNS-1009 Recommended No action is required. You may change the port. Refer to the appropriate hardware reference manual for valid slot and Action port ranges. Severity WARNING ISNS-1011 Message , [ISNS-1011], ,, INFO, , iSNS Client Service - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 398
48 ISNS-1014 Probable Cause Indicates that the internet storage name service (iSNS) client failed to establish a connection with the iSNS server. Recommended Verify the connection of the iSNS server to the slot/port. Use the isnscCfg command to display or Action correct the server IP address. - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 399
primary or backup key vault. Recommended Determine whether the configured key value is operational, and if it is not, change the switch key Action vault settings. Severity ERROR KAC-1004 Message , [KAC-1004], ,, ERROR, , KAC to - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 400
to the primary or backup key vault. Recommended Determine whether the configured key value is operational, and if it is not, change the switch key Action vault settings. Severity ERROR KAC-1008 Message , [KAC-1008], ,, ERROR, , Putting TEP failed check if - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 401
core file information, and contact your switch service Action provider. Severity WARNING KSWD-1002 Message , [KSWD-1002], , FFDC, WARNING, , Detected termination of process :. Probable Cause Indicates - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 402
found, run supportFtp to send all core files to a secure server location. Copy the warning message along with any core file information, and contact your switch service provider. Severity WARNING 344 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 403
name>, Dump memory size exceeds dump file size Probable Cause Indicates the dump memory size has exceeded the dump file size. Recommended No Cannot open ATA dump device Probable Cause Indicates the ATA dump driver is not initialized properly. Recommended No action is required. Action Severity - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 404
51 KTRC-1005 Recommended No action is required. Action Severity ERROR KTRC-1005 Message , [KTRC-1005], ,, ERROR, , Trace initialization failed. . . Probable Cause Indicates that a trace was unable to - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 405
Manager service is enabled. Probable Cause Indicates that the Logical Fabric Manager service is enabled. Note that the Logical Fabric Manager service is prior Logical Fabric Manager configurations. This operation is not supported, currently. Recommended No action is required. Action Severity - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 406
the support. Action Severity CRITICAL LFM-1005 Message , [LFM-1005], ,, WARNING, , Logical port - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 407
or the haFailover command on bladed switches. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING LOG-1002 Message , [LOG-1002], , FFDC - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 408
53 LOG-1003 LOG-1003 Message , [LOG-1003], ,, INFO, , The log has been cleared. Probable Cause Indicates the persistent error log has been cleared. Recommended No action is required. Action Severity INFO 350 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 409
valid link state ID is the same as the valid domain ID, whose range is from 1 through 239. The switch will discard the record because it is not supported. Recommended No action is required. Action Severity ERROR LSDB-1002 Message , [LSDB-1002], ,, INFO, - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 410
for domain Probable Cause Indicates there is no link state record for the specified local domain. Recommended No action is required. The other switch will pass the LSD once the fabric is stable. Action Severity WARNING 352 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 411
persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR MFIC-1002 Message , [MFIC-1002], ,, INFO, , Chassis FRU header not programmed for - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 412
. IDID mode can be set using the configure command in the CLI or checking the Advanced Web Tools Switch Admin > Configure Tab > Fabric Subtab > Insistent Domain ID Mode check box. The switch must be disabled to change the IDID mode. Severity WARNING 354 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 413
Chapter MPTH System Messages 56 MPTH-1001 Message , [MPTH-1001], , FFDC, ERROR, , Null parent, lsId = Probable Cause Indicates a null parent was reported. MPATH uses a tree structure in which the parent is used to connect to the root of the - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 414
56 MPTH-1003 356 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 415
• 7 - MSG_LINIT_IU • 8 - MSG_RSCN • 9 - MSG_IOCTL • 10 - MSG_ACCEPT • 11 - MSG_IU_FREE • 12 - MSG_US • 13 - MSG_EXT_RSCN • 14 - MSG_RDTS_START • 15 - MSG_RDTS_SENDEFP • 16 - MSG_RDTS_RESET Recommended No action is required. Action Severity ERROR Fabric OS Message Reference 357 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 416
57 MQ-1004 358 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 417
Cause Indicates the management server (MS) has segmented from another switch domain at the specified port number because of errors or inconsistencies defined in the MS platform service. Recommended Reboot or power cycle the switch. Action Severity WARNING MS-1002 Message , [MS-1002 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 418
by> Run the firmwareDownload command to upgrade the firmware level on the switch to a level that supports RCS. RCS is supported in Fabric OS v2.6, v3.1 and greater transfers; then run the supportSave command and contact your switch service provider. Severity INFO MS-1004 Message , [MS - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 419
received an information unit (IU) data of unexpected size. The IU payload and the IU size might be inconsistent with each other or with the automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR MS-1008 Message , [MS-1008], - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 420
RLIR event. Switch Port ID is (). Device Port Tag is . < the result of SAN hardware problems such as bad switch service provider. Severity ERROR MS-1022 Message , [MS-1022], ,, INFO, , Management Server Platform Service - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 421
Message , [MS-1023], ,, INFO, , Management Server Topology Discovery Service . Probable Cause Indicates Management Server Topology Discovery Service is being enabled or disabled. Recommended No action is required. Action Severity INFO - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 422
58 MS-1024 364 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 423
If this error occurs repeatedly, then there is a problem in the protocol implementation between two switches. Recommended Action Run the nbrStateShow command to check the neighbor state of the port listed in the message. If it is FULL, then this message can safely be ignored. Otherwise, run the - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 424
the specified port. Neighbor finite state machine (NBFSM) states are as follows: • 0 - Down • 1 - Init • 2 - Database Exchange • 3 - Database Acknowledge Wait • 4 - Database Wait • 5 - Full Recommended No action is required. The Fabric OS automatically recovers from this problem. Action Severity - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 425
is larger than the max frame size the remote switch can support! Probable Cause Indicates the response payload exceeds the maximum frame size the remote switch can handle. Recommended Action Run the firmwareDownload command to upgrade the remote switch with firmware v4.3 or higher, as appropriate - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 426
of the lowest version of firmware. Severity INFO NS-1005 Message , [NS-1005], ,, WARNING, , Zone size of has over the supporting limit of for the remote switch domain ID . Probable Cause - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 427
. Recommended Action Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING Fabric OS Message Reference 369 53 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 428
PDM) process ran out of memory. Recommended Action Reboot or power cycle the switch. If the message persists, run supportFtp (as needed) firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 429
. Recommended Action Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING Fabric OS Message Reference 371 53 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 430
. Recommended Action Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING PDM-1012 Message , [PDM - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 431
firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service PDM-1021], ,, WARNING, , Failed to download area port map. Fabric OS Message Reference 373 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 432
is not supported by older firmware. Recommended Action Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 433
61 PDM-1024 Fabric OS Message Reference 375 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 434
61 PDM-1024 376 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 435
Chapter PDTR System Messages 62 PDTR-1001 Message , [PDTR-1001], ,, INFO, , . Probable Cause Indicates information has been written to the panic dump files. The watchdog register codes are as follows: • 0x10000000 bit set means - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 436
62 PDTR-1002 378 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 437
run the supportSave command and contact your switch service provider. Severity CRITICAL PLAT-1001 Message < a CP that is in the process of becoming the active CP. Note that in certain circumstances a CP may experience problem. If Action the problem still persists, then replace the CP. Fabric - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 438
63 PLAT-1003 Severity CRITICAL PLAT-1003 Message , [PLAT-1003], , FFDC, CRITICAL, , Slot C/BE: ADBUS: misc_intr . Probable Cause - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 439
Chapter PMGR System Messages 64 PMGR-1001 Message , [PMGR-1001], , INFO, , Switch was successfully created. Probable Cause Indicates the switch with the specified FID was successfully created. Recommended No action is required. Action Severity - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 440
64 PMGR-1005 Recommended No action is required. Action Severity WARNING PMGR-1005 Message , [PMGR-1005], , INFO, , Ports on slot to switch were moved successfully. Probable Cause Indicates the successful attempt to move the ports to - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 441
64 PMGR-1009 Recommended No action is required. Action Severity WARNING PMGR-1009 Message , [PMGR-1009], , INFO, , The base switch was successfully changed to switch . Probable Cause Indicates the successful change of the base switch. Recommended - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 442
64 PMGR-1010 384 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 443
L_port. Issue portCfgLport to clear configuration. Indicates the specified port is configured to be an L_port, but the port does not support L_port. If an L_port is connected, then the port will be disabled because the port does not support L_port. If an E_port or F_port is connected, then - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 444
65 PORT-1005 Recommended Invoke the portCfgLport to clear the L_port configuration. Action Severity WARNING 386 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 445
software error has occurred in Advanced Performance Monitoring. The Performance Monitor has failed to initialize. Recommended The CP should reboot (or fail over) automatically. If it does not, reboot or power cycle the switch to Action reinitiate the firmware 's Guide for software activating - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 446
on at least one ISL port. Recommended No action is required. End-to-end monitoring is not supported on ISL ports when ISL monitoring is Action enabled this switch. Probable Cause Indicates that end-to-end monitors are configured on the switch. Recommended Delete end-to-end monitors on that switch - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 447
INFO PSWP-1002 Message , [PSWP-1002], ,, INFO, , Port Swap feature enabled. Probable Cause Indicates the portSwap feature has been enabled in the switch. Recommended No action is required. Action Severity INFO PSWP-1003 Message , [PSWP - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 448
67 PSWP-1003 390 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 449
that the maximum storage size for FFDC data capture is reached. Recommended Run the supportSave command and contact your switch service provider. Action Severity WARNING RAS-1004 Message , [RAS-1004], , FFDC, WARNING, , Software 'verify' error detected - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 450
68 RAS-1006 Probable Cause Indicates an internal software error. Recommended Run the supportSave command and contact your switch service provider. Action Severity WARNING RAS-1006 Message , [RAS-1006], , INFO, , Support data file () - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 451
68 RAS-3001 Probable Cause A user has changed the configured classes of the audit feature. Recommended No action is required. Action Severity INFO RAS-3001 Message , [RAS-3001], , INFO, , USB storage device plug-in detected. Probable Cause Indicates that - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 452
68 RAS-3004 Recommended No action is required. Action Severity INFO 394 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 453
.1 and greater. Run the firmwareDownload command to upgrade the firmware for any switches that do not support RCS. Severity INFO RCS-1002 Message , [RCS . Check memory usage on the switch using the memShow command. Reboot or power cycle the switch. Severity ERROR Fabric OS Message - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 454
in Fabric OS v2.6, v3.1 and greater, and v4.1 and greater. Run the firmwareDownload command to upgrade the firmware for any switches that do not support RCS. Severity ERROR RCS-1005 Message , [RCS-1005], ,, INFO, , Phase , - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 455
, [RCS-1007], ,, ERROR, , Zone DB size and propogation overhead exceeds domain 's maximum supported Zone DB size . Retry after reducing the Zone DB size. Probable Cause Indicates a domain cannot handle the zone database being - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 456
69 RCS-1008 398 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 457
Chapter RKD System Messages 70 RKD-1001 Message , [RKD-1001], ,, INFO, , operation .\nTarget: , Initiator: - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 458
70 RKD-1003 400 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 459
WARNING, , Permission denied accessing certificate file. Secure RPCd is disabled. Probable Cause Indicates the SSL certificate file configured on the switch could not be accessed because the root did not have read-level access. Recommended Change the file system access level for the - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 460
, , Permission denied accessing private key file. Secure RPCd is disabled. Probable Cause Indicates the private key file configured on the switch could not be accessed because the root did not have read-level access. Recommended Change the file system access level for the private key - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 461
Possible detail values include: • RTWRTransmit: Max retries exhausted • detail1: Port • detail2: Domain • detail3: Retry Count • detail4: Status fabricShow command to see if the specified domain ID is online. Enable the switch with the specified domain ID. If the message persists, run supportFtp (as - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 462
ID is reachable. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity INFO 404 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 463
73 SAS-1001 Message , [SAS-1001], ,, ERROR, , string description of command which failed> of GE failed. Please retry the command. Data inst= st= rsn= fn= oid - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 464
73 SAS-1001 406 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 465
is full. This the Introduction to this manual. • fabricd • asd software watchdog will cause the daemon to dump the core and reboot the switch . If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 466
74 SCN-1001 408 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 467
. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR SEC-1002 Message , [SEC-1002], ,, ERROR, , Security data fails: - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 468
switch encountered an error accepting the database download. The primary switch will segment the failed switch after 30 tries. Recommended Action Reset the version stamp on the switch then run the supportSave command and contact your switch service provider. Severity WARNING SEC-1005 Message < - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 469
was reported. The IP address of the unauthorized host is displayed in the message. Recommended Check for unauthorized access to the switch through the HTTP connection. Action Severity INFO SEC-1009 Message , [SEC-1009], ,, INFO, , Security violation - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 470
key infrastructure (PKI) objects exist on the switch. If the private key does not exist, , outlined in the Secure Fabric OS Administrator's Guide. If a certificate does not exist or is Cause Indicates the size of the security database is too large for the flash memory. The size of the security - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 471
75 SEC-1026 SEC-1026 Message , [SEC-1026], ,, ERROR, , Invalid format or character in switch member . Probable Cause Indicates a corruption occurred during the distribution of the security database. This can occur only when the primary - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 472
for that specific switch. Severity ERROR SEC-1031 Message , [SEC-1031], ,, WARNING, , Current security policy DB cannot be supported by standby. CPs will go out of sync. Probable Cause Indicates the security database size is not supported by the standby - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 473
command. Only the secPolicyCreate command supports use of the asterisk for adding switches to policies. Recommended Action Run the secPolicyAdd command using a valid switch identifier (WWN, domain ID, or switch name) to add specific switches to the switch connection control (SCC) policy. Refer - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 474
format. Recommended Run the command again using the standard WWN format, 16 hexadecimal digits grouped as eight Action colon separated pairs. For example: , Invalid port member in portlist (). . Probable Cause Indicates the port member is invalid for - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 475
-number>,, ERROR, , Invalid index/area member in portlist (). Out of range ( - - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 476
of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 477
list . Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 478
of the security database. This can only occur when the primary fabric configurations server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 479
configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in that either no domains or domains more than the maximum number supported are specified. Recommended Enter the correct number of domains. Action - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 480
run the supportSave command Action and contact your switch service provider. Severity ERROR SEC-1071 Message - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 481
. Recommended Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command Action and contact your switch service provider. Severity ERROR SEC-1074 Message , [SEC-1074], ,, ERROR, , Cannot execute the command on this - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 482
-number>,, ERROR, , Failed to activate new policy set on all switches. Probable Cause Indicates the policy could not be activated. Possible reasons that the policy could not be activated include not enough memory or a busy switch. Recommended Run the secFabricShow command to verify - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 483
. Probable Cause Indicates the policy name entered in the secPolicyCreate|Activate|Add|Delete command was invalid. Recommended Run the command again configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 484
of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 485
the security database has more data than can be distributed to some of the switches in the fabric. Recommended Reduce the number of entries in the security policies to decrease the security database size. Action Severity ERROR SEC-1088 Message , [SEC-1088], ,, ERROR - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 486
of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 487
of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 488
automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity ERROR SEC-1098 Message , [SEC-1098], ,, ERROR, , No FCS list. Probable Cause Indicates the specified policy could not - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 489
switches in switches should be in the ready state. If a switch switches in the fabric are in the ready state. When all switches download . Probable Cause Indicates the switch failed to download a certificate, security database, or policies. This can happen when the switch switch switch - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 490
for re-creating PKI objects outlined in the Secure Fabric OS Administrator's Guide. Severity ERROR SEC-1107 Message , [SEC-1107], - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 491
ERROR, , FCS list must be the first entry in the Active Security policies, and the same as the current active FCS list in the switch. Indicates that either a security policy download is attempted with an active policy that does not have the fabric configurations server (FCS) policy as - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 492
75 SEC-1113 Recommended Make sure that the new FCS policy is the same as the current FCS policy on the switch. Action Severity ERROR SEC-1113 Message , [SEC-1113], ,, WARNING, , [ license ] going to expire in days. Probable - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 493
When all switches are in the ready state, retry the operation. Severity INFO SEC-1118 Message , [SEC-1118], ,, INFO, , Fail to set SNMP string. Probable Cause Indicates the SNMP string could not be set. Recommended Usually this problem is transient - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 494
in fabric are in the ready state. When Action all switches are in the ready state, retry the operation. Severity INFO SEC-1123 Message , [SEC-1123], ,, INFO, , Security database downloaded by Primary FCS. Probable Cause Indicates the security database - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 495
INFO SEC-1130 Message , [SEC-1130], ,, INFO, , The Primary FCS has failed over to a new switch. Probable Cause Indicates an FCS failover operation was completed successfully. Recommended Action Verify the security event was planned. If the security - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 496
switch. This message usually indicates that the data package is corrupted, the time stamp on the package is out of range as a result of a replay attack or out-of-sync time service fabric configuration server (FCS) switch received a security database download. Recommended Action Verify that the - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 497
sent from the primary fabric configuration server (FCS) switch. This message usually indicates that the data package is corrupted, the time stamp on the package is out of range as a result of a replay attack or out-of-sync time service, or the signature verification failed. Signature verification - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 498
support RCS, obtain the latest firmware version from your switch supplier, and run the firmwareDownload command to upgrade the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 499
either defined, active, or both. A negative value means that a policy set was failed by the daemon. Recommended Reduce the size of the automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity INFO SEC-1158 Message , [SEC-1158 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 500
updated for that specific switch. Severity INFO SEC-1160 Message , [SEC-1160], ,, INFO, , Duplicate port in port list (). Probable Cause Indicates a duplicate port member exists in the specified port list. Recommended Verify that - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 501
of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 502
of the security database. This can only occur when the primary fabric configurations server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 503
-name>, Failed to set password. Probable Cause Indicates the FCS or non-FCS password could not be set. Recommended Verify all switches in the fabric are in time synchronization with the primary and that no external Action entity is trying to access the fabric. When verification is - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 504
75 SEC-1180 Recommended Verify all switches in the fabric are in time synchronization with the primary [SEC-1183], ,, ERROR, , Policy to binary conversion error: Port is out range. Indicates a security database conversion has failed because of an invalid - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 505
persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR SEC-1184 Message , [SEC-1184], ,, INFO, , configuration change, action - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 506
,, INFO, , Security violation: Unauthorized device tries to FLOGI to index/area of switch . Probable Cause Indicates a device connection control (DCC) security violation was reported. The specified device attempted to login - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 507
75 SEC-1190 SEC-1190 Message , [SEC-1190], ,, INFO, , Security violation: Unauthorized host with IP address tries to do SNMP read operation. Probable Cause Indicates an SNMP security violation was reported. The specified unauthorized host - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 508
of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 509
INFO SEC-1199 Message , [SEC-1199], ,, INFO, , Security violation: Unauthorized access to serial port of switch . Probable Cause Indicates a serial connection policy security violation was reported. An attempt was made to access the - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 510
command was forwarded from a non-primary fabric configuration server (FCS) switch. Recommended Action Check the MS policy and verify that the connection is from MS device node name , device port name . Probable Cause Indicates a management server (MS) security - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 511
FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR SEC-1300 Message , [SEC-1300], ,, INFO, , This switch is in VcEncode mode. Security is not supported. Fabric OS Message Reference 453 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 512
the currently installed software version does not support the Brocade Secure Fabric OS feature. Recommended Run the firmwareDownload command to update the firmware to the latest version for your specific Action switch. Verify the firmware you are installing supports the Brocade Secure Fabric OS - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 513
to validate PKI objects occurs, follow the steps for re-creating PKI objects outlined in the Secure Fabric OS Administrator's Guide. If PKI objects are valid, verify that an unauthorized switch is not trying to access the fabric. Severity INFO Fabric OS Message Reference 455 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 514
/LDAP server identity>. Probable Cause Indicates that after some servers timed out, the specified remote authentication dial-in user service (RADIUS/LDAP) server responded to a switch request. Recommended If the message appears frequently, move the responding server to the top of the RADIUS/LDAP - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 515
more of the password policies is not set to default value. Probable Cause Indicates the security enable failed on the fabric because one or more switches in the fabric have password policies that are not set to the default value. Recommended Action Verify the security event was planned. If the - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 516
to the EM module to retrieve the IP address failed. Recommended Reboot the system to fix this error. If the problem persists contact your switch service provider. Action Severity ERROR SEC-1315 Message , [SEC-1315], ,, ERROR, , command - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 517
join a fabric with strict fabric wide policy Probable Cause Indicates that a domain not supporting an access control list (ACL) policy tried to join a fabric with a strict the security enable failed on the fabric because the switch has a conflicting configuration such as fabric wide consistency - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 518
support a device connection control (DCC) policy with more than 256 ports. Recommended Reconfigure any policy that includes more than 256 ports Probable Cause Indicates the reliable commit service (RCS) transaction failed with the enforcement: Switch connecting to port - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 519
mode failed. Reason: . Probable Cause Indicates the secModeEnable command failed on the fabric because Authentication Policy is enabled on the switch. Recommended Verify the security event was planned. If the security event was planned, run the authUtil --policy Action passive command to - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 520
FTP transfers; then run the supportSave command Action and contact your switch service provider. Severity ERROR SEC-1330 Message , [SEC-1330], fabric because default IP Filter policies are not active on the switch, or an active transaction exists on IP Filter policies. Recommended - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 521
SEC-1333 Message , [SEC-1333], ,, ERROR, , command failed. There are VF enabled switches in fabric. db(s) distribution is blocked. Probable Cause Indicates there was an attempt to distribute PWD - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 522
Policy> ipfilter policy activated. Probable Cause Indicates that that the specified IP filter policy has been activated. Recommended Action Verify that the message. Recommended Check for unauthorized access to the switch through the specified protocol connection. Action Severity INFO SEC - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 523
75 SEC-3051 Recommended Action Verify the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy. Severity INFO SEC-3051 Message , [SEC-3051], - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 524
75 SEC-3051 466 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 525
. Probable Cause Indicates the initialization of the simple network management protocol (SNMP) service failed and you will not be able to query the switch through SNMP. Recommended Reboot or power cycle the switch. This will automatically initialize SNMP. Action Severity ERROR SNMP-1003 Message - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 526
name>, Incorrect SNMP configuration. Probable Cause Indicates the simple network management protocol (SNMP) configuration is incorrect and the SNMP service will not work correctly. Recommended Change the SNMP configuration back to the default. Action Severity ERROR SNMP-1005 Message - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 527
76 SNMP-1008 Severity INFO SNMP-1008 Message , [SNMP-1008], ,, INFO, , The last device change happened at: . Probable Cause Indicates the last device change time. Recommended Execute the nsshow to view the current device status. Action Severity - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 528
76 SNMP-1008 470 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 529
error. Cryptographic operations are affected. Recommended Action For a bladed system, perform slotpoweroff and slotpoweron commands on the blade to recover the system. For a non-bladed system, perform a fastboot command on the switch to recover the system. Severity INFO Fabric OS Message - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 530
>, [SPC-2004], ,, ERROR, , , : FPGA firmware download failed: 0x%x. Probable Cause Indicates the FPGA download failed. Recommended No action is required. Action Severity INFO 472 Fabric OS Message Reference 53 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 531
2005], ,, INFO, , , : FPGA firmware download success: 0x%x. Probable Cause Indicates the FPGA download was successful. Recommended No action is required. Action Severity INFO SPC-2006 Message , [SPC - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 532
77 SPC-2009 SPC-2009 Message , [SPC-2009], ,, CRITICAL, , , : Tamper event: User zeroization. Probable Cause Indicates the Tamper event triggered due to a user zeroize request. Recommended EE is - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 533
77 SPC-3001 SPC-3001 Message , [SPC-3001], ,, ERROR, , , : No input KEK for DEK inject, DEK: , KEK: - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 534
inject a DEK to an invalid FPGA table index • 14 - Invalid input DEK format • 32 - DEK could not be unwrapped • 33 - FGPA error upon inject • 73 - Invalid KEK format Recommended Contact technical support. Action Severity ERROR SPC-3006 Message , [SPC-3006], ,, ERROR - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 535
• 73 - Invalid KEK format • other - Internal error Recommended For status code 14, complete primary KEK generation; otherwise, contact technical support. Action Severity ERROR SPC-3008 Message , [SPC-3008], ,, INFO, , - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 536
77 SPC-3010 SPC-3010 Message , [SPC-3010], ,, WARNING, , , : SEK integrity failure during initialization. Probable Cause Indicates the Crypto Module internal Secret Encryption Key has been corrupted - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 537
compare failure: successive values match. Probable Cause Indicates the Crypto Module internal random number generator failed. Recommended Contact technical support. Action Severity ERROR SPC-3015 Message , [SPC-3015], ,, ERROR, , - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 538
77 SPC-3015 480 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 539
>,, ERROR, , Init fails: . Probable Cause Indicates SPM failed to initialize. Recommended Check system resources and reboot switch. Action Severity ERROR SPM-1002 Message , [SPM-1002], ,, WARNING, , Generic SPM Warning: - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 540
78 SPM-1005 Recommended No action is required. Action Severity INFO SPM-1005 Message , [SPM-1005], ,, INFO, , Set EE Control slot action . Probable Cause User configured. Recommended No action is required. Action Severity INFO SPM-1006 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 541
78 SPM-1009 Recommended No action is required. Action Severity INFO SPM-1009 Message , [SPM-1009], ,, ERROR, , Certificate is missing. Probable Cause User configured. Recommended Run cryptocfg --initnode. Action Severity ERROR SPM-1010 Message - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 542
78 SPM-1010 484 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 543
ip>. Probable Cause Indicates the supportSave command was used to transfer support information to a remote location. Recommended No action is required. command to set the FTP or SCP parameters. Action After the problem is corrected, rerun the supportSave command. Severity WARNING SS-1002 Message - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 544
possible errors in subcommands being executed by the supportSave command. Recommended Run the usbstorage command to check the USB storage device settings. After the USB problem is Action corrected, rerun the supportSave command. Severity WARNING 486 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 545
continue without disruption. Do not fail over or power down the system during firmware upgrade. No action is required. Run the firmwareDownloadStatus Cause Indicates the firmwareDownload command has completed successfully and switch firmware has been updated. Recommended Action No action is - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 546
,, INFO, , Forced failover succeeded. New Active CP is running new firmware. Probable Cause Indicates the previous standby CP has now become the active CP and is running the new firmware version. Recommended Action No action is required. The firmwareDownload command - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 547
failed because FABRIC OS is disabled on Active CP." "Sanity check failed because HAMD is disabled on Active CP." "Sanity check failed because failed." "firmwareDownload failed due to IPC error." "Unable to check the firmware version on Standby CP due to IPC error." "firmwareDownload failed due to - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 548
CP." "firmwareCommit has completed successfully on Standby CP." "Standby CP booted up with new firmware." "Standby CP failed to boot up with new firmware." "firmwareCommit has started on both Active and Standby CPs." "firmwareCommit has completed successfully on both CPs." "firmwareCommit failed on - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 549
be started to recover the 0xa2 blade." "Blade rebooted during firmwareCommit. The operation will be restarted." 0xa3 "Firmware has been downloaded successfully. Blade is rebooting with the new firmware." 0xa4 "Blade has rebooted successfully." 0xa5 "New firmware failed to boot up. Please retry - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 550
. Check whether the switch is supported by the requested firmware. Also check firmwareDownload help page for other possible failure reasons." 0x12 "The RPM package database is inconsistent. Contact your service provider for recovery." 0x13 "Out of memory." 0x14 "Failed to download RPM package - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 551
Cannot download 5.1 because Device Based Routing policy is not supported by 5.1. Use aptPolicy to change the routing policy before proceeding." 0x2d "Invalid RPM package. Please reload firmware packages on the file server." 0x2e "Cannot downgrade due to presence of blade type 17. Remove or power - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 552
blade type in the chassis. Remove or power off the unsupported blades firmware packages on the file server, then retry firmwareDownload. If the problem director-class switch, when firmwareDownload fails, the command will synchronize the firmware on the two partitions of each CP by starting a firmware - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 553
on the standby CP to the same version as the active CP. Then retry firmwareDownload to download the desired version of firmware onto the CPs. Refer to the Fabric OS Administrator's Guide for troubleshooting information. Severity INFO SULB-1010 Message , [SULB-1010], - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 554
and re-insert the blade to trigger another firmwareDownload. If the problem persists, contact your switch service provider. Severity ERROR SULB-1021 Message , [SULB-1021],, AUDIT, WARNING, , Firmware is being downloaded to the blade in slot - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 555
version is still inconsistent with the active CP firmware, firmwareDownload will automatically be restarted on the blade. Run the firmwareDownloadStatus command to monitor the progress. If the problem persists, contact your switch service provider. Severity WARNING SULB-1024 Message - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 556
in slot will reboot with the new firmware. Probable Cause Indicates new firmware has been downloaded to the specified AP blade and that the AP blade will reboot to activate it. Recommended Wait for the blade to reboot. Action Severity WARNING SULB-1026 Message , [SULB - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 557
>, Relocating an internal firmware image on the CP. Probable Cause Indicates the switch has started a firmware download to the co-CPU firmwareDownloadStatus command to monitor the progress. If the problem persists, contact your switch service provider. Severity ERROR SULB-1035 Message - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 558
be relocated again. If the problem persists, Action contact your switch service provider. Severity ERROR SULB-1036 Message , [SULB-1036], ,, INFO, , . Probable Cause Indicates the firmware version running in the - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 559
as inconsistent during failover or recovery. Recommended Action On a Brocade 24000 or 48000 switch, run the slotPowerOff command and then the slotPowerOn command. On a Brocade 7500 or AP7600 switch, reboot or power cycle the switch. Severity ERROR Fabric OS Message Reference 501 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 560
fabric. Recommended Load a firmware version on standby that supports NPIV functionality, using the firmwareDownload Action command. Severity WARNING SWCH-1007 Message Probable Cause , [SWCH-1007], ,, WARNING, , Switch port disabled due to - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 561
that already has area swapped. Recommended Action Replace the blade with ports that support port swap. Then port swap the ports back to ports default area. Refer to the Fabric OS Administrator's Guide for more information on port swapping. Severity WARNING SWCH-1009 Message , [SWCH - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 562
= , Trunk Area enabled on switch = ). Probable Cause Indicates the standby control processor (CP) does not support Trunk Area functionality, but the switch has some ports with Trunk Area enabled. Recommended Load a firmware version - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 563
more programs to register with system services or to fail over to active status. Recommended Action The switch is in an inconsistent state and can be corrected only by a reboot or power cycle. Before rebooting the chassis, record the firmware version on the switch or control processor (CP) and run - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 564
WWN) card). This message occurs only on the Brocade 24000 and 48000. Recommended Action As indicated in firmware. Note that the chassisConfig option 1 should be valid for all platforms running any valid firmware Use the supportSave command to gather troubleshooting data. Issue a reboot or - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 565
Action Run the memShow command to view the switch memory usage. Reboot or power cycle the switch. Run supportFtp as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity CRITICAL SYSM-1002 Message , [SYSM - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 566
CP) is properly seated in its slot. Severity ERROR SYSM-1005 Message , [SYSM-1005], , FFDC, CRITICAL, , CP blade in slot failed to retrieve current chassis type. Probable Cause Indicates there was a failure to read the chassis type from the - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 567
Chapter TAPE System Messages 84 TAPE-1001 Message , [TAPE-1001], , FFDC, INFO, , Key acquisition for . Probable Cause Indicates that the key acquisition for the pool or the container has begun or is complete. - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 568
84 TAPE-1001 510 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 569
WATCHDOG EXPIRED generated by hardware watchdog expiration • MANUAL generated by the tracedump -n command Recommended Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command Action and contact your switch service provider. Severity WARNING TRCE-1002 Message - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 570
persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity ERROR TRCE-1004 Message , [TRCE-1004], ,, WARNING, , Trace dump< optional slot indicating on - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 571
command to verify that the current CP is standby and the active CP is active. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR TRCE-1010 Message , [TRCE-1010 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 572
your switch service provider. Severity ERROR TRCE-1011 Message , [TRCE-1011], ,, INFO, , Trace dump manually blade is enabled and retry the command. If the AP blade is already enabled, run Action the supportSave command and contact your switch service - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 573
message indicates a typing error by an authorized user. If this message occurs repeatedly, it might indicate an unauthorized user trying to gain access to a switch. When Secure mode is enabled on the fabric, the IP address of a failed login is reported to the error log. Severity INFO TRCK-1003 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 574
86 TRCK-1005 Probable Cause Indicates the track change feature recorded a configuration change for the switch. The track change feature records any change to the configuration file in nonvolatile memory, including a configDownload. This message is not generated for a configUpload. All - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 575
the clock server IP configured correctly. Verify this clock server is accessible to the switch and functional. If the principal or primary FCS does not support the feature, either choose a different switch for the role or reset the clock server to LOCL. Severity INFO Fabric OS Message Reference - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 576
Init failed. Time Service exiting Probable Cause: Initialization configuration server (FCS) switch. If the message does role change of the primary FCS switch. If the message does not >. Probable Cause Indicates a switch is trying to set the configuration server (FCS) switch. Another clock server in - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 577
87 TS-1008 Fabric OS Message Reference 519 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 578
87 TS-1008 520 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 579
-1007 Message , [UCST-1007], , FFDC, CRITICAL, , Inconsistent route detected: Port = , should be Probable Cause Indicates the switch detected an inconsistency in the routing database between the routing protocol and the hardware - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 580
>, In-order delivery option has been enabled with Lossless-DLS option. Probable Cause Indicates the IOD option has been enabled for the switch. This option guarantees in-order delivery of frames during topology changes. Recommended No action is required. Action Severity INFO UCST-1026 Message - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 581
1001 Message , [UPTH-1001], ,, WARNING, , No minimum cost path in candidate list Probable Cause Indicates the specified switch is unreachable because no minimum cost path (FSPF UPATH) exists in the candidate list (domain ID list). Recommended No action is - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 582
89 UPTH-1001 524 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 583
Severity INFO WEBD-1005 Message Probable Cause , [WEBD-1005], ,, WARNING, , HTTP server will be restarted for logfile truncation. Indicates the size of the HTTP log file exceeded the maximum limit. Fabric OS Message Reference 525 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 584
logfile truncation. Probable Cause Indicates the size of the HTTP log file exceeded the Probable Cause Indicates the IP address of the switch changed and the HTTP server is restarted. Recommended process has failed to restore HTTP services. The problem often results from invalid configuration of - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 585
message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command to save these core files and contact your switch service provider. Severity ERROR Fabric OS Message Reference 527 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 586
91 ZOLB-1001 528 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 587
zone groups during port login (PLOGI) trap processing. This messages usually indicates problems when adding content- switch service provider. Severity WARNING ZONE-1003 Message , [ZONE-1003], ,, WARNING, , zone() contains (, - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 588
92 ZONE-1005 In session-based zoning, the zone enforcement is checked by the software. In hardware-enforced zoning, zone or the zoning database. If the devices on the port are defined by a mixture of port IDs and WWNs, the zone enforcement is session based. If the S_ID list of the hardware-enforced - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 589
. Recommended Action There are two ways to avoid this problem. • Avoid having too many hosts zoned with a set of target devices at a single port. • Avoid having too many zones directed at a single port group on the switch. Severity INFO ZONE-1008 Message , [ZONE-1008], - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 590
If the QuickLoop zoning configuration is enabled on the switch, it will not be supported. Recommended Edit the zone database to remove the Recommended Install the zoning license using the licenseAdd command. Refer to your switch supplier to obtain a Action Zoning license if you do not have one - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 591
port. This is a software error. A QuickLoop zone type (value = 4) or an uninitialized type (value = 0) are invalid. The valid zone type values are: • hard port zone (value = 1) • hard wwn zone (value = 2) • session based hard zoning (value = 3) • FA zone (value = 5) QuickLoop zones are not supported - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 592
operation. This usually occurs if the switch on the other side of the port is busy. Recommended If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity INFO ZONE-1024 Message - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 593
zone database to keep it within the allowable limit for the specific switches in your fabric. Refer to the Fabric OS Administrator's Guide for information on the zone database sizes supported for each switch. Severity WARNING ZONE-1029 Message Probable Cause Recommended Action , [ZONE - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 594
and contact your switch service provider. Severity WARNING switch, port) members not supported. Probable Cause Indicates the switch is set to interop mode using the interopMode command. Interop mode does not allow members in the active Zone DB size . Probable - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 595
Fabric OS cannot rename the zone configuration file. Typically the zone configuration is too large for the memory available on the switch. Recommended Reduce the size of the zone database and retry the operation. Action Severity ERROR ZONE-1036 Message , [ZONE-1036], - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 596
OS cannot read the zone configuration file. Typically the zone configuration is too large for the memory available on the switch. Recommended Reduce the size of the zone database and retry the operation. Action Severity ERROR ZONE-1040 Message , [ZONE-1040], ,, INFO - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 597
ZONE-1041 Severity INFO ZONE-1041 Message , [ZONE-1041], ,, WARNING, , Unstable link detected during merge at port (). Probable Cause Indicates a possible unstable link or faulty cable. Recommended Check the SFP and cable at the specified - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 598
, [ZONE-1047], ,, INFO, , Switch domain () does not support defined database. Probable Cause Indicates a remote Brocade switch is running a downlevel version of Fabric OS that does not support the defined database. Recommended It is recommended to - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 599
92 ZONE-1049 ZONE-1049 Message , [ZONE-1049], ,, ERROR, , ZONE AD-DefZone conflict detected while system initialization. Probable Cause Indicates that there is an AD-DefZone conflict. Recommended Check and resolve the default zone mismatch issue. Action - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 600
92 ZONE-1053 ZONE-1053 Message , [ZONE-1053], ,, INFO, , The Default Zone state is set to Disabled. Probable Cause Indicates the Interop Default Zone attribute state is disabled. Recommended Verify if the Interop Default Zone attribute state change was - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 601
553 •AUDIT FICU System Messages 555 •AUDIT FW System Messages 557 •AUDIT HTTP System Messages 559 •AUDIT IPAD System Messages 561 •AUDIT PORT System Messages 563 •AUDIT SEC System Messages 565 •AUDIT SNMP System Messages 579 •AUDIT SULB System Messages 581 •AUDIT SWCH System Messages 593 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 602
- HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 603
Chapter AUDIT AG System Messages 89 AG-1029 Message AUDIT, , [AG-1029], INFO, CFG, , , , F_Port to N_Port mapping has been updated for N_Port . Probable Cause Indicates that the F_Ports mapped to an N_Port have changed and the config - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 604
89 AG-1029 546 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 605
Chapter AUDIT AUTH System Messages 90 AUTH-3001 Message AUDIT, , [AUTH-3001], INFO, SECURITY, , , , Event: , Status: success, Info: type has been changed from [] to []. Probable Cause Indicates - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 606
that an invalid entity attempted to connect to the switch. Recommended Action Check the connection port for a possible security attack. Check the shared ; then run the supportSave command and contact your switch service provider. Severity INFO 548 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 607
automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity INFO AUTH-3008 Message AUDIT, , [AUTH- location>, , Event: , Status: failed, Info: Port has been disabled due to authentication failure with code '< - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 608
90 AUTH-3008 550 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 609
[CONF-1022], WARNING, CFG, , , , Downloading configuration without disabling the switch was unsuccessful. Probable Cause The system attempted to download a configuration without disabling the switch was unsuccessful because there are one or more parameters - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 610
91 CONF-1022 552 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 611
Chapter AUDIT FCIP System Messages 92 FCIP-1002 Message AUDIT, , [FCIP-1002], INFO, CFG, , , , An IPsec/IKE policy was added. Probable Cause Indicates that an IPsec/IKE policy was added and the config file was updated. Recommended No action - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 612
92 FCIP-1003 554 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 613
Chapter AUDIT FICU System Messages 93 FICU-1011 Message AUDIT, , [FICU-1011], INFO, CFG, , , , FMS mode has been enabled. Probable Cause Indicates the FICON Management server mode has been enabled. Recommended No action is required. Action - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 614
93 FICU-1012 556 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 615
INFO, , , , Event: , Status: success, Info: Probable Cause Indicates that Port Fencing was enabled/disabled successfully. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 557 53-1001157 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 616
94 FW-3001 558 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 617
Chapter AUDIT HTTP System Messages 95 HTTP-1002 Message AUDIT, , [HTTP-1002], INFO, ZONE, , , , Zoning transaction initiated by User: , Role: completed successfully. Probable Cause Indicates that the zoning database has - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 618
95 HTTP-1003 560 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 619
[IPAD-1002], INFO, CFG, , , , Switchname has been successfully changed to . Probable Cause Indicates that a change with the switch name has occured. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 561 53 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 620
96 IPAD-1002 562 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 621
No action is required. Action Severity INFO PORT-1007 Message AUDIT, , [PORT-1007], INFO, CFG, , , , Port (ID: ) has been renamed to . Probable Cause Indicates a port has been reconfigured with a different name - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 622
97 PORT-1009 Probable Cause Indicates a GigE port has been disabled. Recommended No action is required. Action Severity INFO 564 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 623
Event Name can be one of the following: • There has been an fabric configurations server (FCS) failover. • A security policy has been activated. • A security policy has been saved. • A security policy has been aborted. • A non-FCS password has changed. Recommended Action Verify the security event - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 624
98 SEC-3004 Recommended Action Verify the new policy creation was planned. If the new policy creation was planned, no action is required. If the new policy creation was not planned, take appropriate action as defined by your enterprise security policy. Severity INFO SEC-3004 Message AUDIT, < - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 625
98 SEC-3007 Recommended Action Verify the removal of members to the policy was planned. If the removal of members was planned, no action is required. If the removal of members was not planned, take appropriate action as defined by your enterprise security policy. Severity INFO SEC-3007 Message - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 626
98 SEC-3010 SEC-3010 Message AUDIT, , [SEC-3010], INFO, SECURITY, , , , Event: , Status: success, Info: Reset [] security stat(s). Probable Cause Indicates a user has reset all the security statistics - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 627
name> to position . Probable Cause Indicates a user has changed the position of the remote authentication dial-in user service (RADIUS) server. Recommended Action Verify the RADIUS server position was intentionally changed. If the RADIUS server position was intentionally changed - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 628
Status: success, Info: . Probable Cause Indicates a user has changed the remote authentication dial-in user service (RADIUS) configuration. Recommended Action Verify the RADIUS configuration was intentionally changed. If the RADIUS configuration was intentionally changed, no - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 629
exceeded. The account has been locked as a result. Recommended The account may automatically unlock after the lockout duration has expired or an administrator Action may manually unlock the account. Severity INFO Fabric OS Message Reference 571 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 630
98 SEC-3024 SEC-3024 Message AUDIT, , [SEC-3024], INFO, SECURITY, , , , Event: , Status: success, Info: User account [], password changed. Probable Cause Indicates the user's password was changed. Recommended Action - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 631
98 SEC-3028 Recommended Action Verify the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy. Severity INFO SEC-3028 Message AUDIT, , [SEC- - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 632
SEC-3032 Message AUDIT, , [SEC-3032], INFO, SECURITY, , , , Event: , Status: success, Info: Switch is configured to database. Probable Cause Indicates the specified event has occurred to accept or - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 633
initiator-details>, , , Event: ipfilter, Status: success, Info: ipfilter policy activated. Probable Cause Indicates the specified IP filter policy has been activated. Recommended Action Verify the security event was planned. If the security event was planned, no - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 634
Cause Indicates the specified IP filter policy failed to activate. Recommended Action Verify the security event was planned. If displayed in the message. Recommended Check for unauthorized access to the switch through the specified protocol connection. Take Action appropriate action as defined - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 635
98 SEC-3044 SEC-3044 Message AUDIT, , [SEC-3044], INFO, SECURITY, , , FIPS mode has been changed to . Probable Cause Indicates there was a change in the FIPS mode. Recommended Action Verify the security event was planned. If the - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 636
98 SEC-3048 SEC-3048 Message AUDIT, , [SEC-3048], INFO, SECURITY, , , FIPS mode has been enabled in the system using force option. Probable Cause Indicates the system has been forced to FIPS mode. Recommended Action Verify the security event - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 637
, Incorrect SNMP configuration. Probable Cause Indicates that the simple network management protocol (SNMP) configuration s incorrect and the SNMP service will not work correctly. Recommended Reset the SNMP configuration to default. Action Severity ERROR SNMP-1005 Message Probable Cause AUDIT - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 638
99 SNMP-1006 580 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 639
continue without disruption. Do not fail over or power down the system during firmware upgrade. Run the firmwareDownloadStatus command for more information. Cause Indicates the firmwareDownload command has completed successfully and switch firmware has been updated. Recommended Action No action is - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 640
failed because FABRIC OS is disabled on Active CP." "Sanity check failed because HAMD is disabled on Active CP." "Sanity check failed because failed." "firmwareDownload failed due to IPC error." "Unable to check the firmware version on Standby CP due to IPC error." "firmwareDownload failed due to - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 641
CP." "firmwareCommit has completed successfully on Standby CP." "Standby CP booted up with new firmware." "Standby CP failed to boot up with new firmware." "firmwareCommit has started on both Active and Standby CPs." "firmwareCommit has completed successfully on both CPs." "firmwareCommit failed on - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 642
be started to recover the 0xa2 blade." "Blade rebooted during firmwareCommit. The operation will be restarted." 0xa3 "Firmware has been downloaded successfully. Blade is rebooting with the new firmware." 0xa4 "Blade has rebooted successfully." 0xa5 "New firmware failed to boot up. Please retry - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 643
. Check whether the switch is supported by the requested firmware. Also check firmwareDownload help page for other possible failure reasons." 0x12 "The RPM package database is inconsistent. Contact your service provider for recovery." 0x13 "Out of memory." 0x14 "Failed to download RPM package - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 644
Cannot download 5.1 because Device Based Routing policy is not supported by 5.1. Use aptPolicy to change the routing policy before proceeding." 0x2d "Invalid RPM package. Please reload firmware packages on the file server." 0x2e "Cannot downgrade due to presence of blade type 17. Remove or power - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 645
blade type in the chassis. Remove or power off the unsupported blades firmware packages on the file server, then retry firmwareDownload. If the problem director-class switch, when firmwareDownload fails, the command will synchronize the firmware on the two partitions of each CP by starting a firmware - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 646
on the standby CP to the same version as the active CP. Then retry firmwareDownload to download the desired version of firmware onto the CPs. Refer to the Fabric OS Administrator's Guide for troubleshooting information. Severity INFO SULB-1010 Message AUDIT, , [SULB-1010], INFO - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 647
another firmwareDownload. If the problem persists, contact your switch service provider. Severity ERROR SULB-1021 Message AUDIT, , [SULB-1021], WARNING, FIRMWARE, , , , Firmware is being downloaded to the blade in slot . Probable - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 648
version is still inconsistent with the active CP firmware, firmwareDownload will automatically be restarted on the blade. Run the firmwareDownloadStatus command to monitor the progress. If the problem persists, contact your switch service provider. Severity WARNING SULB-1024 Message AUDIT - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 649
command to monitor progress. If the problem persists, contact your switch service provider. Severity WARNING SULB-1031 Message AUDIT, , [SULB-1032], WARNING, FIRMWARE, , , , Relocating an internal firmware image on the CP. Probable Cause - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 650
to be relocated again. If the problem persists, Action contact your switch service provider. Severity ERROR SULB-1037 Message AUDIT, , [SULB-1037], ERROR, FIRMWARE, , , , HCL failed. Reboot the switch manually using the reboot command. However - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 651
INFO, CFG, , , , Trunk Area has been disabled for one or more ports. Probable Cause Indicates Trunk Area assignment has been disabled for one or more ports and the config file has been updated. Recommended No action is required. Action Severity INFO SWCH - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 652
101 SWCH-1014 594 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 653
details>, , , In-order delivery option has been enabled. Probable Cause Indicates the IOD option has been enabled for the switch. This option guarantees in-order delivery of frames during topology changes. Recommended No action is required. Action Severity INFO UCST-1022 Message - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 654
>, , In-order delivery option has been enabled with Lossless-DLS option. Probable Cause Indicates the IOD option has been enabled for the switch. This option guarantees in-order delivery of frames during topology changes. Recommended No action is required. Action Severity INFO UCST-1026 Message - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 655
Severity INFO 102 UCST-1027 Fabric OS Message Reference 597 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 656
102 UCST-1027 598 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 657
AUDIT ZONE System Messages Chapter 103 ZONE-3001 Message AUDIT, , [ZONE-3001], INFO, ZONE, , , , Event: , Status: success, Info: \"\" added to \" - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 658
103 ZONE-3004 The zone object type can be "alias", "zone member", "zone" or "zone configuration". The string "..." appears at the end of the zone object member list if the list was truncated in the message. Recommended Verify the event was planned. If the event was planned, no action is required. - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 659
103 ZONE-3007 ZONE-3007 Message AUDIT, , [ZONE-3007], INFO, ZONE, , , , Event: , Status: success, Info: Zone configuration \"\" enabled. . Probable Cause Indicates the specified zone configuration has been - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 660
initiator-details>, , , Event: , Status: success, Info: has been activated. Probable Cause Indicates the specified admin domain (AD) has been activated. Recommended Verify the event was planned. If the event was planned, no action is required. If the - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 661
103 ZONE-3015 An AD object set type is "AD member". The string "..." appears at the end of the AD object member list if the list was truncated in the message. Recommended Verify the event was planned. If the event was planned, no action is required. If the event was not Action planned, take - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 662
103 ZONE-3018 ZONE-3018 Message AUDIT, , [ZONE-3018], INFO, FABRIC, , , , Event: , Status: success, Info: has been deactivated. Probable Cause Indicates the specified admin domain (AD) object has been deactivated. - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 663
103 ZONE-3022 Severity INFO ZONE-3022 Message AUDIT, , [ZONE-3022], INFO, FABRIC, , , , Event: , Status: success, Info: Current AD configuration saved to flash. Probable Cause Indicates the current admin domain (AD) configuration - HP StorageWorks 4/8 | Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 664
103 ZONE-3025 Severity INFO 606 Fabric OS Message Reference 53-1001157-01
53-1001157-01
24 November 2008
Fabric OS
Message Reference
Supporting Fabric OS v6.2.0