53-1000599-01 19 Oct 2007 Fabric OS Command Reference Manual Supporting Fabric OS v6.0.0 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 2
SAN Health, and Tapestry are trademarks of Brocade Communications Systems, Inc., in the United States and/or in other countries. FICON is a registered trademark of IBM Corporation in the U.S. and other countries. All other brands, products, or service names are or may be trademarks or service Brocade - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 3
Communications Systems, Incorporated Corporate Headquarters Brocade Communications Systems, Inc. 1745 Technology Drive San Jose, CA 95110 Tel: 1-408-333-8000 Fax: 1-408-333-8101 Email: [email protected] European and Latin American Headquarters Brocade Communications Switzerland Sàrl Centre Swissair - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 4
Fabric OS Command Reference Manual Fabric OS Command Reference Manual 53-0000519-12 53-1000240-01 53-1000436-01 53-1000599-01 Summary of Changes Publication Date July 2005 September 2006 15 Jun 2007 Added 13 new commands, Updated 23 commands with new options in support of v6.0. Removed 46 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 5
Is Organized xvii Supported Hardware and Software xvii What's New in This Document xviii Document Conventions xxi Additional Information xxiii Getting Technical Help xxiv Document Feedback xxv Chapter 1 Using Fabric OS Commands Understanding Role-Based Access Control 1 Understanding - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 6
bladeEnable 46 burninErrClear 48 burninErrShow 49 burninLevel 50 burninStatus 51 cfgActvShow 52 cfgAdd 53 configDefault 74 configDownload 75 configList 79 configRemove 80 configShow 81 configUpload 83 configure 86 dataTypeShow 93 date 94 dbgShow 96 defZone 97 diagClearError 99 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 7
Fabric OS Command Reference 53-1000599-01 diagEnablePost 101 diagEnv 102 diagFailLimit 104 diagHelp 105 diagPost 106 diagRetry 107 diagSetBurnin 108 diagSetCycle 109 diagShow 110 diagSkipTests 111 diagStatus 112 diagStopBurnin 113 dbgShow 114 distribute 115 dlsReset 117 dlsSet 118 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 8
fanEnable 145 fanShow 146 fastboot 147 fastwritecfg 148 fazoneAdd 150 fazoneCreate 151 fazoneDelete 153 fazoneRemove 154 fazoneShow 155 fcipChipTest 156 fcipPathTest 158 fcLunQuery 160 fcPing 161 fcpLogClear 163 fcpLogDisable 164 fcpLogEnable 165 fcpLogShow 166 fcpProbeShow 167 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 9
233 fwFruCfg 238 fwHelp 239 fwMailCfg 240 fwPortDetailShow 242 fwSamShow 245 fwSet 246 fwSetToCustom 247 fwSetToDefault 248 fwShow 249 h 252 haDisable 253 haDump 254 haEnable 256 haFailover 257 haShow 258 haSyncStart 260 haSyncStop 261 ix - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 10
help 262 historyLastShow 263 historyMode 264 historyShow 265 httpCfgShow 267 i 268 ifModeSet 270 ifModeShow 272 interfaceShow 273 interopMode 277 iodReset 280 iodSet 281 iodShow 282 ipAddrSet 283 ipAddrShow 286 ipfilter 287 iscsiCfg 290 iscsiChipTest 298 iscsiHelp 299 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 11
Fabric OS Command Reference 53-1000599-01 lsDbShow 327 memShow 330 miniCycle 331 minisPropShow 336 msCapabilityShow 337 msConfigure 338 msPlatShow 340 msPlatShowDBCB 341 msPlClearDB 342 msPlMgmtActivate 343 msPlMgmtDeactivate 344 msTdDisable 345 msTdEnable 346 msTdReadConfig 347 myId - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 12
perfClearAlpaCrc 392 perfClearFilterMonitor 393 perfDelEEMonitor 394 perfDelFilterMonitor 395 perfHelp 396 perfMonitorClear 397 perfMonitorShow 399 perfSetPortEEMask 403 perfShowAlpaCrc 405 perfShowEEMonitor 406 PerfTTmon 408 pkiCreate 411 pkiRemove 412 pkiShow 413 policy 414 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 13
Fabric OS Command Reference 53-1000599-01 portDebug 471 portDisable 472 portEnable 473 portErrShow 474 portFlagsShow 475 portLedTest 476 portLogClear 477 portLogConfigShow 478 portLogDisable 479 portLogDump 480 portLogDumpPort 481 portLogEnable 482 portLogEventShow 483 portLoginShow - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 14
powerOffListSet 535 powerOffListShow 537 psShow 538 reboot 539 routeHelp 540 secActiveSize 541 secAuthSecret 542 secCertUtil 544 secDefineSize 547 secGlobalShow 548 secHelp 550 secPolicyAbort 551 secPolicyActivate 552 secPolicyAdd 553 secPolicyCreate 555 secPolicyDelete 558 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 15
Fabric OS Command Reference 53-1000599-01 snmpConfig 591 spinFab 598 statsClear 601 stopPortTest 602 supportFfdc 603 supportFtp 604 supportSave 606 supportShow 610 supportShowCfgDisable 615 supportShowCfgEnable 616 supportShowCfgShow 617 switchBeacon 618 switchCfgPersistentDisable 619 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 16
690 zoneObjectExpunge 691 zoneObjectRename 692 zoneRemove 693 zoneShow 694 Primary FCS Commands Primary FCS Commands 695 Control Processor Commands Commands Supported on the Standby CP 697 Command Availability Command Validation Checks 699 Command RBAC Permissions and AD Types 700 xvi - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 17
Brocade 48000 directors. • Appendix A, "Command Availability,"explains the Role-Based Access Control checks used to validate commands, and provides the availability of every command, for every user role. • The Index points you to the exact pages on which specific information is located. Supported - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 18
switch • Brocade 5000 switch • Brocade 7500 switch • Brocade AP 7600 switch • Brocade 24000 director • Brocade 48000 director • Brocade DCX Data Center Backbone director Procedures or parts of procedures documented here may apply to some hardware platforms, but not to others. For hardware specific - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 19
support new features in Fabric OS 6.0.0 since this document was last released: • aaaConfig • ag • configDownload • configShow • configUpload • configure routing tables, interfaces, masquerade connections, or multicast memberships. By default, netstat lists open sockets. For a list of all netstat - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 20
and each has different behavior when invoked. The pages have been removed from this manual. Note that some of the corresponding manpages have not been updated to reflect the unsupported status of these commands. PLATFORM-BASED COMMANDS These commands will be blocked from running on the new 4G, 8G - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 21
CHASSIS-BASED COMMANDS These commands are still allowed to run on Brocade 48000 and DCX platforms in order to maintain consistency across mixed blade environments lettercase is all lowercase. If there are exceptions, this manual specifically notes those cases in which a command is case sensitive. - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 22
, and warnings The following notices and statements are used in this manual. They are listed below in order of increasing severity of potential hazards these conditions or situations. Key terms For definitions of SAN-specific terms, visit the Storage Networking Industry Association online dictionary - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 23
register at no cost for a user ID and password. For practical discussions about SAN design, implementation, and maintenance, you can obtain Building SANs with Brocade Fabric Switches through: http://www.amazon.com For additional Brocade documentation, visit the Brocade SAN Info Center and click the - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 24
Brocade Web Tools-Administration, configuration, and maintenance of fabric switches and SANs • Brocade Advanced Zoning-Division of a fabric into virtual private SANs IPSec - IP Security (for the Brocade 7500 and FR4-18i blade in the Brocade 48000) NPIV - N-port ID Virtualization, allowing up to 256 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 25
or fabric behavior immediately • following the problem, and specific questions • Description of any troubleshooting steps already performed and the results • Serial console and Telnet session logs • syslog message logs 2. Switch Serial Number The switch serial number and corresponding bar code are - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 26
Provide the title and version number and as much detail as possible about your issue, including the topic heading and page number and your suggestions for improvement. xxvi Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 27
Fabric OS Commands Chapter 1 This chapter explains how to manage a Brocade SAN and Brocade switches and directors using the Fabric OS command line interface (CLI). The following topics discussed: • "Understanding Role-Based Access Control" on page 1 • "Understanding Admin Domain Restrictions" on - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 28
in this manual. Using the Command Line Interface The Fabric OS command line interface (accessed via telnet, SSH, or serial console) provides full management capability on a Brocade switch. The Fabric OS CLI enables an administrator to monitor and manage individual switches, ports, and entire - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 29
of its syntax, a description of command use, and a set of examples. The same information can be accessed by issuing help command.on a Brocade switch or director. This command displays the help page (also called man page) for the specified command. For example, to display the help or man page for - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 30
1 Using the Command Line Interface 4 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 31
manual for specific details. Configuration changes are persistently saved and take effect with the next AAA request. The configuration applies to all switch instances in a platform supporting multiple switch domains. Customers can use centralized RADIUS servers to manage AAA services for a switch - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 32
conf radius|ldap Specifies the server configuration as either RADIUS or LDAP. This operand is required. -p port Specifies the RADIUS or LDAP server port number. Supported range is 1 to 65535. The default port is 1812 for RADIUS authentication. The default port is 389 for LDAP authentication. This - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 33
a semi-colon separated list of AAA services. Services must be enclosed in quotation marks. The following AAA services and service pairs are valid: "local" Default setting. Authenticates the user against the local database only. If the password does not match or the user is not defined, the login - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 34
if none of the primary AAA services is available. Displays command usage. Examples To display the current RADIUS configuration: switch:admin> aaaconfig --show RADIUS CONFIGURATIONS Position Server Port Secret Timeout(s) Auth-Protocol 1 192.168.233.48 1812 sharedsecret 3 2 192.168.233.44 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 35
buffer. The transaction buffer contains only the required changes for the Defined configuration. For --save, the changes in the transaction buffer are sent to all other switches and saved to the Defined configuration (in persistent storage). For --apply, it performs a save operation, sends a request - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 36
Domain and create relevant zone configuration and zones (zone --copy could be used for this). Enable the new zone configuration under the Admin Domain; port control and zoning on the switch port and the devices attached to that port. • PI can be specified as a range; for example, D,[0-34]. The port - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 37
a switch WWN based on the current fabric information. Operations with switch list will fail if the domain ID to switch WWN lookup fails. switch_list Grants switch administrative operations such as switchDisable, switchEnable, reboot, ad, and so forth. Ownership of a switch implicitly provides port - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 38
switch_list" Creates a new administrative domain with the specified device and switch list. Newly created Admin Domains are in an activated state. configuration exists under the Admin Domain. This operation is not allowed on AD0. ad --deactivate does not result in any port disables. All existing user - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 39
Saves the outstanding Admin Domain transaction to the defined configuration in all the switches in the fabric. The saved Admin Domain definition enforces configuration and effective configuration is displayed. A mode flag can be used to display information from a specific configuration alone - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 40
support Exchange Service Support (ESS), and therefore the Name Server cannot get the correct port range of such switches clear all Admin Domain definitions: switch:admin> ad --clear You are about to delete all ADs definitions. This operation will fail if zone configurations exists in AD1-AD254 Do you - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 41
ad --deactivate 5 You are about to deactivate an AD. This operation will fail if an effective zone configuration exists in the AD Do you want to deactivate '5' admin domain (yes, y, no, n): [no] y To delete AD13: switch:admin> ad --delete 13 You are about to delete an AD. This operation will fail if - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 42
16 To select a new Admin Domain context by specifying the AD number: switch:admin> ad --select 12 To display all ADs: switch:admin> ad --show Current AD: 255 : AD255 Transaction buffer configuration no configuration Defined configuration AD: 1 : AD1 Active Device WWN members: Switch port - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 43
15; 10:00:00:60:69:00:02:53; To display the Admin Domain effective configuration information: switch:admin> ad --show -m 2 Current AD: 255 : AD255 Effective configuration AD: 1 : AD1 Active Device WWN members: Switch port members: Switch WWN members: 21:00:00:80:e5:12:8b:37; 21:00:00:80:e5 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 44
the AD transaction (yes, y, no, n): [no] y See Also To display the current Admin Domain transaction: switch:admin> ad --transshow Current transaction token is 26816 It is abortable switch:admin> ad --transshow There is no outstanding zoning transaction cfgSave, cfgTransShow, defZone, logout 18 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 45
manages failover of an F_Port to a set of related N_Ports in a port group. Auto Port Configuration is disabled by default. When this policy is enabled, the AG enabled switch will automatically detect available ports and map F_ports to N_ports. --policyenable policy name Enables the specified - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 46
more specified F_Ports from the "primary" N_Port mapping. --pgshow [Port Group ID] Displays Port Group configuration. The port grouping feature supports specifying a set of N_Ports to be included in the Port Group (PG) Policy. The factory default PG is "pg0", which includes all N_Ports. It can not - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 47
ag 2 --pgremove pgid Deletes the specified. the port group. --failoverenable N_Port Enables the failover policy for a given N_Port Enables the failback policy for a specified N_Port. When failback policy is enabled, ports behave as follows: • If only primary F_Port to N_Port mapping is in place, - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 48
secondary N_Port can be configured. The list of F_Ports to be mapped must be enclosed in quotation marks. Port numbers must be and 12: switch:admin> ag --show Name : switch_ST1 NodeName : 10:00:00:05:1e:35:9b:e7 Number of Ports : 16 IP Address(es) : 10.115.74.53 Firmware Version : v6 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 49
> ag --policyeanble auto All Port related configurations will be lost. Please save the current configuration using configupload. Do you want to continue? (yes, y, no, n): [no] y 5. To disable auto policy when switch is disabled: switch:admin> ag --policydisable auto Default factory settings will be - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 50
to this N_Port by user (saved in config). - Failover and Failback indicate whether or not N_Port policy is enabled (1) or disabled (0). - PG_ID is the Port Group ID and PG_Name is the Port Group Name. 2. To clear all F_Ports mapped to the configured primary N_Port 0: switch:admin> ag --mapset - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 51
2 1 3 0 2. To set and display failover and failback policies on a single port: switch:admin> ag --failoverenable 1 Failover policy is enabled for port 1 switch:admin> ag --failoverdisable 0 Failover policy is disabled for port 0 switch:admin> ag --failovershow 0 Failover on N_Port 17 is not - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 52
PG_ID N_Ports PG_Name 0 None pg0 2 0;2 MyEvenFabric 3 1;3 FirstFabric 4. To remove port group with pgid 2: switch:admin> ag --pgremove 2 Port Group 2 has been removed successfully switch:admin> ag --pgshow PG_ID N_Ports PG_Name 0 0;2 pg0 3 1;3 FirstFabric AG - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 53
:admin> ag --prefdel "7;8;9" 3 Preferred N_Port is deleted successfully for the F_Port[s] See Also 3. To set secondary port mapping for F_Ports 7, 8 and 9: switch:admin> ag --prefset "7;8;9" 3 Preferred N_Port is set successfully for the F_Port[s] portCfgNPort, portCfgNPIVPort Fabric OS Command - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 54
10:00:00:00:c9:3f:7c:b9 To display the locally registered Access Gateways: switch:admin> agshow --local Worldwide Name Ports Enet IP Addr Firmware Local/Remote Name 10:00:00:05:1e:04:06:ae 24 10.32.173.64 v6.0.0 local L5D2_B14_4024_1 28 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 55
display all Access Gateways attached to the fabric: switch:admin> agshow Worldwide Name Ports Enet IP Addr Firmware Local/Remote Name 10:00:00:05:1e:02:b7:2c 16 10.32.173.62 v6.0.0 remote L5D2_B10_4016_1 10:00:00:05:1e:04:06:ae 24 10.32.173.64 v6.0.0 local L5D2_B14_4024_1 10:00:00:05 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 56
configuration must be enabled using the cfgEnable command. Notes This command requires a Brocade Advanced Zoning license. When FCS policy is enabled, this command can be issued only from the primary FCS switch methods: • A switch domain and port area number pair. For ports using the switchShow - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 57
to represent a specific port and slot combination. Area numbers are automatically assigned to a port by the Fabric OS. You can view the Area numbers using the switchShow command. This command changes the defined configuration (see cfgShow). For the change to be preserved across switch reboots, it - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 58
to become effective, an appropriate zone configuration must be enabled using the cfgEnable command. Notes This command requires a Brocade Advanced Zoning license. When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands This command has the following - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 59
configuration must be enabled using the cfgEnable command. Notes This command requires a Brocade Advanced Zoning license. When FCS policy is enabled, this command can be issued only from the primary FCS switch methods: • A switch domain and port area number pair. For ports using the switchShow - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 60
those that match in the defined configuration are displayed. This command can be issued only from the primary FCS switch. Operands This command has the of the nonvolatile memory. The default value is 0. If no parameters are specified, all zone configuration information (both defined and effective - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 61
little or no oversubscription of the ISLs. Note that static routes are supported only with this policy. 3 Exchange-based routing policy (default). With this policy, the path chosen for an ingress frame is based on: • Ingress port on which the frame was received • FC address of the source fabric - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 62
change the current APT policy: switch:admin> switchdisable switch:admin> aptpolicy -ap 1 Policy updated successfully. switch:admin> switchenable switch:admin> aptpolicy Current Policy: 3 1(ap) 3 0(ap): Default Policy 1: Port Based Routing Policy 3: Exchange Based Routing Policy 0: AP Shared Link - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 63
audit log configuration. This command allows user to set filters by configuring certain classes using the --class option. To add or remove any of the classes in the filter list, re-issue --class option. All filters can be disabled by the --disable option. Based on the configuration, certain classes - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 64
. Refer to the Fabric OS Administrator's Guide for details on FIPS configuration. --policy Sets the Switch authentication policy or Device authentication policy. The following sub-operands are supported: -sw on|off|active|passive set switch authentication policy. Specify one of the following - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 65
number if applicable. portnumber Specify the port number. On chassis-based systems, use the slot/port format for specifying the port number. allE Specify all E_ports in the switch. Examples To display authentication configuration on the switch: switch:admin> authutil --show AUTH TYPE HASH - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 66
> authutil --policy -dev passive Warning: Activating the authentication policy requires DH-CHAP secrets on both switch and device. Otherwise, the F-port will be disabled during next F-port bring-up. ARE YOU SURE (yes, y, no, n): [no] y Device authentication is set to PASSIVE To start authentication - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 67
. Synopsis bannerset [banner] Description Use this command to set the banner on the local switch. The banner is a string of alphanumeric characters. It is displayed whenever a user tries to log in to a switch. The banner can be created using the banner operand or by entering the bannerSet command - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 68
is subject to Admin Domain restrictions that may be in place. Operands none Examples To display the banner for a switch: switch:admin> bannershow Banner: Do not log into this switch if you are not an authorized administrator. See Also bannerSet 42 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 69
as a set of hexadecimal bit maps. Each bit in a bit map represents a port, with the least significant bit in each row representing port 0, 32, 64, and so on. The output from this command varies, depending on switch type. The execution of this command is subject to Admin Domain restrictions that - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 70
from left to right and right to left. The pattern continues until the user turns it off. This can be used to locate a physical unit. Beaconing mode only takes over the port LEDs; it does not change the switch's functional behavior. The normal flashing LED pattern (associated with an active, faulty - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 71
Use this command to disable all user ports on a blade. All ports on the blade are taken offline. If the switch was connected to a fabric through this blade, the remaining switches reconfigure, and this switch will configure based on the other blade ports. The blade must be disabled before making - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 72
this command to enable all user ports on a blade. All ports within the blade that did not fail the power-on self-test (POST) are enabled (except for persistently disabled ports); they might come online if connected to a device or remain offline if disconnected. If the switch is connected to a fabric - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 73
See Also 4 SW BLADE 2 ENABLED 5 CP BLADE 1 ENABLED 6 CP BLADE 1 ENABLED 7 SW BLADE 2 ENABLED 8 UNKNOWN VACANT 9 UNKNOWN VACANT 10 UNKNOWN VACANT bladeDisable, portDisable, portEnable, switchShow bladeEnable 2 Fabric OS Command Reference 47 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 74
is a follows: slotnumber A nonzero value that specifies the slot number from which to clear burn-in errors. Examples To clear burn-in errors from slot 2. switch:admin> burninerrclear 2 See Also burninErrShow 48 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 75
as follows: slotnumber A nonzero value that specifies the slot number from which to display burn-in errors. Examples To display burn-in errors from slot 2: switch:admin> burninerrshow 2 See Also burninErrClear Fabric OS Command Reference 49 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 76
(POST) phase II each time a switch blade is powered on. The mode becomes active as soon as this command is executed so that it does not require a reboot to take effect. When a burn-in level other than 0 is selected, actual behavior is determined by the configuration of the diagnostics daemon and the - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 77
Use this command to display the burn-in status of each blade in the system. The output contains the slot, state, current , all slots are displayed. Examples To display the burn-in status for all slots: switch:admin> burninstatus Slot State Status Run 1 ABORT PASS 3 2 ABORT PASS 3 3 ABORT - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 78
initiator sees are based on this configuration. The effective configuration is built when a specified zone configuration is enabled. This command requires a Brocade Advanced Zoning license. Operands none Examples To display the effective zone configuration information: switch:admin> cfgactvshow - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 79
to become in effect, an appropriate zone configuration must be enabled using the cfgEnable command. Notes This command requires a Brocade Advanced Zoning license. When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands This command has the following - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 80
in nonvolatile memory for all the switches in the fabric. If no current zoning configuration exists, use the cfgSave command. If the default zone access mode is "No Access", then this command re-creates the default zoning objects. Notes This command requires a Brocade Advanced Zoning license. When - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 81
and member specifications. Notes This command requires a Brocade Advanced Zoning license. When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands This command has the following operands: "cfgName" Specify a name for the zone configuration, in quotation - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 82
to become in effect, an appropriate zone configuration must be enabled using the cfgEnable command. Notes This command requires a Brocade Advanced Zoning license. When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands This command has the following - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 83
d_efault_Cfg". See defZone. Notes This command requires a Brocade Advanced Zoning license. When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands none Examples To disable the current zone configuration: switch:admin> cfgdisable You are about to disable - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 84
to the cfgShow command for a description of defined and effective configurations. Notes This command requires a Brocade Advanced Zoning license. When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands This command has the following operand: "cfgName - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 85
or disabling safezoning or default zoning on one switch in the fabric will enable or disable the specific feature fabric wide, meaning that the feature will be disabled or disabled on all switches in the fabric. This command cannot be executed unless the Brocade switch/director is in McDATA fabric - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 86
to become in effect, an appropriate zone configuration must be enabled using the cfgEnable command. Notes This command requires a Brocade Advanced Zoning license. When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands This command has the following - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 87
to save the current zone configuration. The defined configuration and the name of the enabled configuration are written to nonvolatile memory in all switches in the fabric. The saved configuration is automatically reloaded by the switch on power on and, if a configuration was in effect at the - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 88
command cannot be executed unless the Brocade switch/director is in McDATA fabric mode. Operands The cfgSaveActiveToDefined command has no operands. Examples Execute the cfgShow command to view defined and effective zoning configurations. switch:admin> cfgShow Default Zone: OFF Safe Zone: OFF - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 89
enabled. The devices that an initiator sees in the fabric are based on this configuration. The effective configuration is built when a specific zone configuration is enabled and all error checking has been completed successfully. When default zoning is enabled with "No Access" mode, "No Effective - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 90
default value is 0. This operand is optional. Examples To display all zone configurations that start with "Test": switch configuration information: switch:admin> cfgshow Defined configuration :71:df Effective configuration: cfg: USA_cfg zone To display only configuration names: switch:admin> cfgshow - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 91
to ad for a description of defined and effective Admin Domain configurations. Notes This command requires a Brocade Advanced Zoning license. When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands This command has the following operand: integer If - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 92
the zone configuration database restored to the state before the transaction was started. If a transaction is open on a different switch in the fabric when this command is run, the transaction on the other switch remains open and unaffected. Notes This command requires a Brocade Advanced Zoning - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 93
transaction. Notes This command requires a Brocade Advanced Zoning license. When FCS policy is enabled, this switch:admin> cfgtransshow There is no outstanding zone transactions switch:admin> cfgclear Do you really want to clear all configurations? Clearing All zoning configurations... switch - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 94
chassis configuration options on the Brocade DCX Data Center Director. By default the switch will support 384 ports in a single Fiber Channel domain. The chassisconfig command is no longer available on this platform. Brocade 48000 directors support only options 1 and 5. 1 One 128-port switch (blade - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 95
To display the current configuration option on a Brocade 48000 director and to change the option: switch:admin> chassisconfig Current Option: 5 All Supported Options (With Blade ID 5 on slots 5-6 Option 1: One 128-port switch (Blade ID 4, 17 on slots 1-4, 7-10, Blade ID 5, 16 on slots 5-6) Option - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 96
Use this command to display or change the name associated with the chassis. In dual-domain systems, there are up to two logical switches associated with a single chassis. Operands This command has the following operand: name Specify a new name for the chassis, optionally in quotation marks - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 97
POWER SUPPLY, SW BLADE (switch), CP BLADE (control processor), WWN (World Wide Name), or UNKNOWN. Object number: Slot nn (for blades supplied serial number (up to 20 characters): Serial Num: a switch: switch:user> chassisshow Chassis Backplane Revision: 1C SW BLADE Slot: 3 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 98
Num: 1 -180 60-0001532-03 1013456800 Day: 12 Month: 6 Year: 2001 Day: 15 Month: 7 Year: 2001 28 days 16 days 555-374757 234-294-12345 2734658 A.00 CP BLADE Slot: 6 Header Version: Power Consume Factor: Factory Part Num: Factory Serial Num: Manufacture: Update: Time Alive: Time Awake: ID: Part Num - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 99
the goes in panic mode. The maximum number of saved entries for this command is 512. Operands None Examples To display the command history on a switch: switch:admin> clihistory Command History: 09:14:17.6924 1 admin, 192.168.163.233, version 10:25:36.8875 1 admin, 192.168.100.19, clihistory 12 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 100
, zones, and configurations) • Security parameters and policies • User account passwords (includes all user config and all built-in accounts) • Switch PID format • Ethernet Link Mode Refer to the configure command for more information on default values for configuration parameters. Notes This - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 101
user to download only specific changes. Refer to configUpload for a description of the configuration file format. The configDownload command supports password if necessary. The SSH service is available on Unix and Windows hosts. The third form of the configDownload command retrieves the configuration - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 102
to the current switch configuration. It is therefore possible to change a single configuration variable by downloading a file with a single line. All other variables remain unchanged. The configuration parameters R_A_TOV, E_D_TOV, WAN_TOV, and MAX_HOPS are interrelated. Assigning a specific value to - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 103
interactive mode, prompting the user for input. Note that "host" is not required when -local or -USB is specified. NOTE Once a configuration file has been uploaded to an external system, it must NOT be manually edited before being downloaded, either to the same or another switch. Such an operation - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 104
2 configDownload configDownload complete: All config parameters are downloaded See Also configDefault, configList, configShow, configUpload, configure, configRemove, configRemoveAll 78 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 105
.) Examples To display a list of configuration files stored on the local chassis: switch:admin> configlist -local config.txt config2.txt next_cfg.txt 25679 25679 20977 2007 Jan 02 15:16 2007 Jan 06 15:16 2007 Jan 18 15:16 See Also configDownload, configUpload, configShow, configRemove - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 106
file option is omitted, the command will prompt the user to specify a file name. Examples To remove a configuration file from the local chassis: switch:admin> configremove -local first_config.txt switch:admin> To remove a configuration file from an attached USB device without specifying a filename - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 107
common regular expression operators is not supported. Some configuration settings will not display when filtered. file is omitted, the command will prompt the user to specify a file name. The output format content of the local configuration file: 1. List the file: switch:admin> configlist -local - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 108
] [Licenses] [Chassis Configuration] [Configuration] acl.clear:0 ag.port.nfportfailback:0x0 ag.port.nfportfailover:0x0 ag.port.nfporttopo.0:0x0 ag.port.nfporttopo.1:0x0 ag.port.nfporttopo.10:0x0 [output truncated] 3. Filter the configuration file display output: switch:admin> configshow -local - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 109
of the following reasons: • The host name is not known to the switch. • The host IP address cannot be contacted. • The user does not have permission on the host. • The FTP server is not running on the host. The configuration file contains three types of lines: licenses, section headers, and name - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 110
The [fcRouting] section contains the Fibre Channel Router configuration. • The [iSCSI] section contains the iSCSI configuration. • The [Banner] section contains the banner header information. For Admin Domain users, refer to the Fabric OS Administrator's Guide for details regarding configUpload and - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 111
that any existing file can be overwritten. Without this option, the user will be prompted to confirm such overwrites. When invoked without operands or manually edited before being downloaded, either to the same or another switch. Such an operation will bypass sanity checks for some configuration - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 112
the following system configuration settings for the switch: • Switch fabric settings • Virtual channel parameters • F_Port login parameters • Zoning operation parameters • Remote State Change Notifications (RSCN) transmission mode • Arbitrated Loop Parameters • System Services Settings • Portlog - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 113
to suit specific applications or operating environments but must be in agreement among all switches to allow formation of the fabric. The following Switch Fabric Settings can be modified: TABLE 2 Configure Command Fabric Parameters (* = multiplication symbol) Field Type Default Range Domain - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 114
By default, the switch can send Class F frames. When this option is turned on, Class F traffic is converted to Class 2 traffic before being transmitted. Per-frame Route Priority In addition to the eight virtual channels used in frame routing priority, support is also available for per-frame-based - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 115
. Virtual Channel Settings The switch enables fine-tuning for a specific application by configuring the parameters for eight virtual channels. The first two virtual channels are reserved for switch internal functions and are not available for modification. The default virtual channel settings have - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 116
RSCN is sent to the end-device for the switch IP address or name change. Arbitrated Loop Parameters The Arbitrated Loop Setting fields are described in the table. TABLE 7 Configure Command Arbitrated Loop Settings Field Default Send FAN frames? 1 Enable CLOSE on OPEN received? 4 Always - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 117
. TABLE 9 Configurable Application Attributes Application File Type Default Range ssl rpcd cfgload Webtools Certificate File CA Certificate File Length of crypto key Secure RPCd Callback secret Enforce secure Config Upload/Download Enforce signature validation for firmware Basic User Enabled - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 118
parity error will cause the problem blade to be powered off. Examples To enable signed firmware download on a disabled switch: switch:admin> configure Configure... Fabric parameters (yes, y, no, n): [no] Virtual Channel parameters (yes, y, no, n): [no] F-Port login parameters (yes, y, no, n): [no - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 119
. Examples To display sample data streams you can use with diagnostics: switch:admin> datatypeshow Pattern type example BYTE_FILL WORD_FILL QUAD_FILL BYTE_NOT WORD_NOT QUAD_NOT BYTE_RAMP 01 02 05 0b 17 2f 5e bd 7b f6 ec d8 b0 60 c0 11 55 16 fc d7 17 65 a9 87 5f 44 be 5a d0 de bc a5 12 bc - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 120
switch is forwarded to the principal switch and distributed to the fabric. It may take up to 64 seconds for the switches support. If the switch is operating in FICON Management Server mode (fmsmode), setting the date is subject to the director switch:admin> date Fri Jan 29 17:01:48 UTC 2007 switch: - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 121
date 2 See Also errShow, ficonCupSet, ficonCupShow, portLogShow, tsClockServer, tsTimeZone, upTime Fabric OS Command Reference 95 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 122
view the debug and verbosity levels. Module names are case sensitive. This operand is optional. Examples To display information about a specific module named NS: switch:admin> dbgshow NS Module NS, debug level = 1, verbose level = 1 See Also setDbg 96 Fabric OS Command Reference 53-1000599 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 123
If the current effective zone configuration is disabled with the cfgDisable command, the local switch converts this command to the equivalent of cfgEnable d_efault_Cfg. • If zoning receives a cfgDisable command from a remote switch that does not support default zoning, zoning rejects the cfgDisable - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 124
the default zone access mode. Notes This command requires a Brocade Advanced Zoning license. This command must be run from the primary FCS switch. Zone configuration. Examples To create a default zone configuration: primaryfcs:admin> cfgactvshow Effective configuration: No Effective configuration - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 125
is set to 0 and designed to operate on fixed-port-count products. -all If specified, all blades clear. If no operand is specified, the default is to clear all bad port flags. Examples To clear the diag software flag: switch:admin> diagclearerror 8 ERROR: DIAG CLEARERR Diagnostics Errors Cleared - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 126
POST. A reboot is not required for this command to take effect. Operands none Examples To disable the POST during future power ons: switch:admin> diagdisablepost Config update Succeeded Diagnostic POST is now disabled. See Also diagEnablePost 100 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 127
command is subject to Admin Domain restrictions that may be in place. Operands none Examples To enable the POST during future power ons: switch:admin> diagenablepost Config update Succeeded Diagnostic POST is now enabled. See Also diagDisablePost Fabric OS Command Reference 101 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 128
technicians but users. Diagnostic parameters are used primarily for debugging purposes and users should not Brocade 7500, 4900, and AP 7600. The command is allowed to run on these platforms to maintain consistency across mixed blade environments, but it does not affect the operations of the switch - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 129
See Also USR_SEED DIAG_USR_SEED USR_SPECIAL DIAG_USR_SPECIAL (output truncated) none diagEnv 2 0x0 0x0 Fabric OS Command Reference 103 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 130
of failures before certain diagnostic test methods aborts. The exact use of this configuration setting depends on the test method. The fail limit is saved in To change the fail limit from 1 to 5: switch:admin> diagfaillimit -show Fail Limit is 1. switch:admin> diagfaillimit 5 Fail Limit is now 5. - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 131
execution. This process takes a few seconds to complete. Use default operands when running diagnostics commands. Non-default settings require detailed knowledge of the underlying hardware and are intended for support personnel only. Contact support if you want to use these operands. The execution of - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 132
Sets or displays diagnostic POST configuration. Synopsis diagpost [mode | -show] Description Use this command to enable or disable Power-On-Self-Test) POST daemon program to inhibit testing of switch blades when the system is first powered on or a new blade is added. To enable or disable - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 133
to take effect. Retry mode modifies the behavior of the diagnostic test methods, power-on self-test (POST), and burn-in scripts. The exact behavior depends on is displayed. Examples To view the current retry mode value: switch:admin> diagretry -show Diagnostic Retry Mode is currently enabled. See - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 134
available from the burninErrShow command on a per-blade basis. When power cycles occur, the burn-in activity is restarted at the test to current burn-in script. Examples To set the burn-in script and mode: switch:admin> diagsetburnin --slot 1 -current existing script is: /fabos/share/switchess.sh Burnin - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 135
script is specified, the command displays all configuration variables used by the specified script and enter an interactive session. Using the full parameters, variables can be updated noninteractively. In interactive mode, the current value, default value, and description of purpose of the variable - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 136
this value is not 0 the diagnostics status for the blade ports specified in -use_bports displays; otherwise, the user ports specified in -uports displays. The default value is 0. Examples To display diagnostic status on a switch blade: switch:admin> diagshow Diagnostics Status: Fri Feb 08 15:25 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 137
test flags are used to skip the execution of certain POSTs that might prove hazardous to normal switch operation. The exact use of this flag is determined by the POST scripts and the specific test methods used. Operands This command has the following operands: value Specify a bit mask for tests - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 138
such as the FR4-18i, FA4-18, FC10-6, Brocade 7500, 4900, and AP 7600. The command is allowed to run on these platforms to maintain consistency across mixed blade environments, but it does not affect the operations of the switch. Operands The follow is optional: slotnumber Specifies the slot - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 139
command to determine which PID is running burn-in on a blade and terminate that activity. The burn-in script handles the logging executes on all slots in the logical switch. This operand is optional. Examples To stop burn-in mode on a switch: switch:admin> diagstopburnin --slot 1 No burn-in - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 140
view the debug and verbosity levels. Module names are case sensitive. This operand is optional. Examples To display information about a specific module name NS: switch:admin> dbgshow NS Module NS, debug level = 1, verbose level = 1 See Also setDbg 114 Fabric OS Command Reference 53-1000599 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 141
DCC Device Connection Control Policy PWD Password Database and Password Configuration Policy AUTH E_port and F_port Authentication Policy FCS Fabric Configuration Server Policy IPFILTER IP-Filter Policy Each supported database has a switch-local configuration parameter that controls whether the - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 142
" -d "*" Wildcard domains are: 1 3 5 To distribute the FCS policy, and the Password database to all domains in the fabric that support the distribute feature: switch:admin> distribute -p "FCS;PWD" -d "*" To distribute the AUTH and FCS policies to all switches in the fabric that run v5.3.0 or later - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 143
change occurs. Refer to dlsSet for a full description of load sharing. This command should occasional routing changes correctly. DLS is not supported in certain routing policies. Refer to load sharing option: switch:admin> dlsreset Committing configuration...done. switch:admin> dlsshow DLS is - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 144
Routing is generally based on the incoming port and the destination domain. This means that all the traffic coming in from a port (either an E_Port achieved with this setting. The DLS option is on by default. DLS is not supported in certain routing policies. Refer to aptPolicy for more information - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 145
. Refer to dlsSet for a description of load sharing. DLS is not supported in certain routing policies. Refer to aptPolicy for more information on routing policies Examples To display the current DLS option setting: switch:admin> dlsshow DLS is set See Also dlsSet, dlsReset Fabric OS Command - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 146
place. Operands none Examples To set the DNS parameters for the system: switch:admin> dnsconfig Enter option 1 Display Domain Name Service (DNS) configuration 2 Set DNS configuration 3 Remove DNS configuration 4 Quit Select an item: (1..4) [4] 2 Enter Domain Name: [] domain.com Enter Name Server - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 147
attributes of the switch enclosure. Currently, supported attributes are the vendor-specific enclosure identifier and the identifier of the enclosure interface to which the switch is attached. This command is only meaningful for the products that are embedded in a blade server or storage chassis - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 148
instances on this control processor (CP). Synopsis errclear Description Use this command to clear all internal and external error log messages for all switch instances on this CP. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 149
instead displays the existing errDelimiterSet configuration. These delimiters are stored persistently display the start and end delimiter: switch:admin> errdelimiterset delimiter start string: errdelimiterset -s "Start" -e "End" - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 150
OS versions prior to v4.2. Examples To display the error log, without pagination: switch:user> errdump Version: 4.4.0 2004/07/14-22:24:08, [HAMK-1003], 1,, violation: Login failure attempt via SERIAL. See Also errDelimiterSet, errFilterSet, errShow 124 Fabric OS Command Reference 53-1000599- - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 151
set a filter for an error log destination. A filter is set based on the severity level of the messages. If no parameters are specified, "ERROR", or "CRITICAL". Examples To display the current filter settings: switch:admin> errfilterset console: filter severity = WARNING See Also To set the - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 152
be in place. Operands none Examples To display a list of all defined error log modules: switch:user> errmoduleshow Module IDs: 1 KT 2 UT 5 LOG 6 CDR 9 PIXE 10 EGR 13 CHPS 4 KTRC 8 PISP 12 PIC 16 AUTH 20 CER 24 CONF See Also errDump, errShow 126 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 153
OS versions prior to v4.2. Examples To display the error log, with pagination: switch:user> errshow Version: 4.4.0 2004/07/14-22:24:08, [HAMK-1003], 1,, SEC-1192], 3,, INFO, switch2, Security violation: Login failure attempt via SERIAL. Type to continue, Q to stop: See Also errDelimiterSet, errDump - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 154
. Telnet and rlogin connections are closed; the serial port returns to the login: prompt. The exit command is an accepted synonym for logout, as is typing Ctrl-D at the beginning of a line. Operands none Examples To exit from a shell session: switch:admin> exit Connection to host lost. See - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 155
the fabric, as well as a list of pending commands. The following information displays: Port The port number. State The state of the port: P0 Port Offline P1 Port Online P2 ELP ACC Received P3 Link Reset Done I0 Trunk Initiator: EMT Sent I1 Trunk Initiator: ETP ACC Received I2 Trunk - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 156
Neighboring switch's WWN nbrPort Neighboring switch's port lr_tid Link reset timer port number to display, relative to its slot for bladed systems. Use switchShow to list valid ports. Examples To display fabric port information: switch:admin> fabportshow 4/14 Fabric Port Information Port - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 157
See Also Flags: nbrWWN: nbrPort: lr_tid: red_ports: 10 11 62 63 0x280120 10:00:00:60:69:80:06:cf 5 0x1005dbd8, IDLE STATE Open commands pending No commands pending portShow fabPortShow 2 Fabric OS Command Reference 131 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 158
display the retry count of the fabric commands. The SW_ISL (ISL ports) information displays the retry count for the following fabric commands: ELP To display the retry count of Fabric OS commands: switch:user> fabretryshow SW_ILS E_Port ELP EFP HA_EFP DIA RDI BF FWD EMT ETP RAID GAID ELP_TMR - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 159
clear Clears fabric log. -d | --disable Disables fabric log. By default, the fabric log is enabled. -e | --enable Enables fabric log power of 2; otherwise, the command fails. Examples To change the number of entries: switch:admin> fabriclog -s Time Stamp Input and *Action S, P Sn,Pn Port - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 160
2 fabricLog See Also Are your sure you want to do the resize [y/n]? y switch:admin> fabriclog -s Time Stamp Input and *Action S, P Sn,Pn Port Xid fabPortShow, fabStatsShow 134 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 161
this command to set principal switch selection mode for the switch. The implementation of the fabricPrincipal command is based solely on mechanisms specified in the Fibre Channel standards. These mechanisms provide a preference for a switch requesting to be the principal switch in a fabric, but they - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 162
. Examples The following example illustrates a fabric of four switches. "sw180" is the Principal switch. Three of the switches are configured to run IP over Fibre Channel. switch:admin> fabricshow Switch ID Worldwide Name Enet IP Addr FC IP Addr Name 64: fffc40 10:00:00:60:69:00:06:56 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 163
show a mixed fabric with an IPv4 and IPV6 configured switches: sw5:admin> fabricShow Switch ID Worldwide Name Enet IP Addr FC IP Addr Name 1: fffc41 10:00:00:60:69:00:02:0b 192.168.64.180 192.168.65.180 >"sw180" 1080::8:800:200C:1234/64 2: fffc42 10:00:00:60:69:00:05 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 164
to Admin Domain restrictions that may be in place. Operands none Examples To clear the fabric state information: switch:admin> fabstateshow Time Stamp Input and *Action S, P Sn,Pn Port Xid 11955:655 SCN Switch Online F2,NA F2,NA NA NA 11955:657 *Start 2 * F_S_TOV Timer F2,NA F2,NA NA - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 165
New number of entries. It has to be at least 2 and a power of 2; otherwise, the command fails. Examples To change the number of entries: switch:admin> fabstateshow Time Stamp Input and *Action S, P Sn,Pn Port Xid 11955:655 SCN Switch Online F2,NA F2,NA NA NA 11955:657 *Start 2 * F_S_TOV - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 166
to Admin Domain restrictions that may be in place. Operands none Examples To display the fabric state information: switch:admin> fabstateshow Time Stamp Input and *Action S, P Sn,Pn Port Xid 11955:655 SCN Switch Online F2,NA F2,NA NA NA 11955:657 *Start 2 * F_S_TOV Timer F2,NA F2,NA NA - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 167
fabstatsshow Description Use this command to display the statistics for the fabric. The information displays as follows: • Number of times a switch domain ID has been forcibly changed • Number of E_Port offline transitions • Number of fabric reconfigurations • Number of fabric segmentations due - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 168
2 fabStatsShow Eport Isolated: 0 See Also fabRetryShow 142 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 169
Fabric Switch State Structure Information State: D0 Stage: warm done Rdi Receive Timer: 0x10069400, IDLE STATE Unconfirmed Sw Timer: 0x10069508, IDLE STATE NTP Timer: 0x100695b8, IDLE STATE ME Timer: 0x10069610, IDLE STATE Principal Domain: 2 Upstream Port: 64 Principal - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 170
speed to 0. This command is not available on nonbladed systems except for the Brocade 4100 and 4900. The execution of this command is subject to Admin Domain fan unit number to disable. Examples To disable a fan unit: switch:admin> fandisable 1 Fan unit 1 has been disabled See Also fanEnable - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 171
. Synopsis fanenable unit Description Use this command to set a previously disabled fan unit back to the default RPM speed. This command is not available on nonbladed systems except for the Brocade 4100 and 4900. The execution of this command is subject to Admin Domain restrictions that may be - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 172
fan speed is displayed. The output from this command varies depending on switch type and number of fans present. The execution of this command is in place. Operands none Examples To display information on the fans in the system: switch:admin> fanshow Fan #1 is OK, speed is 2721 RPM Fan #2 is OK - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 173
2 fastboot Reboots the Control Processor (CP), bypassing Power-On Self-Tests (POST). Synopsis fastboot Description Use To reboot the Control Processor, without executing POST on startup: switch:admin> fastboot See Also diagDisablePost, diagEnablePost, reboot Fabric OS Command Reference 147 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 174
on the Brocade FC-IP/FC Router blade (FR4-18i) on a 7500, 48000 or DCX platform. When FC fastwrite is enabled, GE Ports are not allowed to be enabled on the blade. The blade will come up with GE ports internally disabled. A maximum of four user ports per port group (0-7 or 8-15) may be configured as - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 175
WARNING !!!! Disabling this feature requires power-cycling of the affected blade to take effect and may take up to 5 minutes to complete. Non-bladed switches will be rebooted. In all cases, data traffic on all the ports (FC and GbE) of the blade will be disrupted. Continue (Y,y,N,n): [ n] portcfg - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 176
This command does not change the defined configuration (which you can view using the . For the change to be preserved across switch reboots, it must be saved to nonvolatile number pair (for example, "1,2"). View the area numbers for ports using the switchShow command. • WWNs (for example, "10 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 177
:00:8a" would contain devices connected to switch 2, ports 12 and 14, and the device with a WWN of "10:00:00:60:69:00:00:8a" (either node name or port name: whichever port in the fabric it is connected to.) This command does not change the defined configuration (which you can view using the - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 178
number pair (for example, "1,2"). View the area numbers for ports using the switchShow command. WWNs (for example, "10:49: port numbers and Fabric Assist zone aliases: switch:admin> fazoneCreate "Red_fazone", "H{1,0};loop1" switch:admin> fazoneCreate "Blue_fazone", "H{1,1};array1; 1,2;array2" switch - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 179
mode zone on a fabric. This command does not change the defined configuration (which you can view using the cfgShow command). For the change be enabled using the cfgEnable command. For the change to be preserved across switch reboots, it must be saved to nonvolatile memory using the cfgSave command. - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 180
This command does not change the defined configuration (which you can view using the cfgShow . For the change to be preserved across switch reboots, it must be saved to nonvolatile pair (for example, "1,2"). View the area numbers for ports using the switchShow command. WWNs (for example, "10:49 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 181
match in the defined configuration are displayed. When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands This command , the value defaults to 0. Examples To display all Fabric Assist zones beginning with the letters A through C: switch:admin> fazoneshow - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 182
only on Brocade FR4-18i blades and Brocade 7500 platforms. Operands This command has the following operands: --slot slotnumber Specifies the slot number on which the diagnostic operates. The default is 0 and operates on fixed-port-count products. -testtype type Specifies the test type to - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 183
See Also fcipPathTest fcipChipTest 2 Fabric OS Command Reference 157 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 184
Channel frames or data packets transmitted from and received by the network processor due to the designated loopback. This command is supported only on Brocade FR4-18i blades and Brocade port. The default value is 100. -length data compression for the test. By default, data compression is used. This - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 185
fcipPathTest 2 Running fcippathtest Test Complete: fcippathtest Pass 10 of 10 Duration 0 hr, 1 min & 50 sec (0:1:50:942). passed. Diagnostics See Also When a failure is detected, the test might report one or more of the following: PATH_TEST_ERR PATH_TEST_CHIP_INIT_ERR PATH_TEST_IMAGE_ERR - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 186
in the name sever is displayed. Uses commas to separate a list of WWNs. -s Displays the port and node WWNs which will be used for any LUN query from this switch. Examples To display the LUN information: switch:user> fclunquery Target Index: 1 Target Node WWN: 50:05:07:65:05:03:f9:39 Target - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 187
Fibre Channel Extended Link Service (ELS) Echo request to a pair of ports. ELS Echo requests. The default is 0 seconds. -p pattern Specifies up to 16 "pad" bytes, which are used to fill out the request frame payload sent. This is useful for diagnosing data-dependent problems - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 188
the destination port ID, port WWN, or node WWN. Examples To display one device that accepts the request and another device that rejects the request: switch:admin> the request and another device that does not respond to the request: switch:admin> fcping 0x020800 22:00:00:04:cf:75:63:85 Source: - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 189
execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To clear the FCPD debug information log: switch:admin> fcplogclear See Also fcpLogDisable, fcpLogEnable, fcpLogShow Fabric OS Command Reference 163 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 190
execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To disable the FCPD debug information log: switch:admin> fcplogdisable See Also fcpLogClear, fcpLogEnable, fcpLogShow 164 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 191
(debug command). Synopsis fcplogenable Description Use this command to enable the debug information logged for FCPD. Debug information logging is enabled by default. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To enable the - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 192
at various stages of FCP device probing. Operands none Examples To display the FCPD debug information log: See Also Time Stamp Event Port file&lineno arg0 arg1 arg2 arg3 arg4 08:20:12.274 FlshOrProbe 0 1 536 2 :0 :0 :0 :0 08:20:12.275 ProbeFlsh 0 1 3031 0 :0 :0 :0 :0 08:20:12 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 193
fcpProbeShow 2 fcpProbeShow Displays the Fibre Channel Protocol (FCP) probe information. Synopsis fcpprobeshow for bladed systems. Use switchShow to list valid ports. This operand is required. Examples To display the FCP probe information: switch:admin> fcpprobeshow 4/4 port 52 is L-Port and - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 194
2 fcpRlsShow fcpRlsShow Displays the Fibre Channel Protocol (FCP) Read Link Status (RLS) information. the port number to display, relative to its slot for bladed systems. Use switchShow to list valid ports. This operand is required. Examples To display the FCP RLS information: switch:admin> - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 195
. Valid values are 1-128. --help Displays the list of actions possible. EXAMPLES To display the current configuration of the switch. switch:admin> frcbcastconfig --show Broadcast configuration is disabled for: fid 2 fid 128 fid 33 SEE ALSO bcastshow, portRouteShow Fabric OS Command Reference - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 196
register N is reached (0x80000000 for a 32-bit register). For example, a 6- Brocade FR4-18i blades and Brocade 7500 platforms. Operands This command has the following operands: --slot slotnumber Specifies the slot number on which the diagnostic operates. The default is 0 and operates on fixed-port - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 197
fcrChipTest 2 Diagnostics When a failure is detected, the test might report one or more of the following: DMA_ALLOC_FAIL DMA_READ_ABORT DMA_READ_TIMEOUT CHIP_INIT_TIMEOUT BIST_TIMEOUT BIST_FAIL See Also fcrPathTest, miniCycle, portLoopbackTest Fabric OS Command Reference 171 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 198
the following parameter: Backbone Fabric ID A fabric ID uniquely identifies a fabric in FC Router configurations. The backbone fabric is the fabric attached to the U_Ports-for example, E/F_Ports-of this switch. The backbone fabric ID must be unique across all FC Router-connected fabrics. The current - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 199
. The existing invocation syntax is maintained for IPv6 support. When IPv6 addresses are not configured, the output of fabricshow is the same as Dom ID: 2, Info: 10.32.66.220, 220::10:32:66:220 "sw220n" EX_Port FID Neighbor Switch Info (enet IP, WWN, name) 16 80 10.32.66.180 10:00:00: - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 200
2 fcrFabricShow See Also fcrPhyDevShow, fcrProxyDevShow, fcrRouteShow, lsanZoneShow, switchShow 174 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 201
be configured on the router. By default, supported as valid count. Operands If no operands are specified, this command displays the current LSAN zone limit. This command has the following operands: max-lsan-count Specifies the new LSAN count. Examples To display the current LSAN limit: switch - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 202
information for all the FCR switches in the backbone that supports this command. Using the command options, the user can do the following: • the persistent memory (CLI command with no option). • Display the static and default/dynamic binding of the backbone to show which edge fabrics have two-way - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 203
Fabric ID 2 4 5 4 7 10 19 To view the LSAN Zone static and default/dynamic binding in the backbone: For example, in the backbone where online fabrics are: 1, 2, 4, 5, 7, 8, 10 switch:admin > fcrlsanmatrix --fabricview LSAN MATRIX is activated Fabric ID 1 Fabric ID 2 4 5 4 7 10 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 204
:06:2b:0e:4d:e5 52 10:32:16:90:28:dd:d0:03 52 10:32:16:91:24:dd:d0:07 52 10:32:16:91:25:dd:d0:06 78 10: To apply the changes persistently: switch:admin > fcrlsanmatrix --apply View all the static and the default/dynamic fabric binding in the backbone. switch:admin > fcrlsanmatrix --fabricview LSAN - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 205
path. The path exercised in this test does not include the media nor the fiber cable. Only one frame is transmitted and received at any one time. External cable is not required to run this test. The port LEDs flicker green rapidly while the test is running. The test method is as - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 206
2 fcrPathTest This command is supported only on Brocade FR4-18i blades and Brocade 7500 platforms. Operands This command has the following operands: --slot slotnumber Specifies the slot number on which the diagnostic operates. The default is 0 and operates on fixed-port-count products. -unit - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 207
physical devices include physical devices that are configured to be exported from fabrics attached to this FC Router's EX_Ports. The physical devices are listed by fabric. The -f and -w operands allow searching for physical devices based on fabric ID or port World Wide Name. "No device found" is - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 208
2 fcrPhyDevShow in Fabric 2 10:00:00:00:c9:2b:6a:68 c70000 3 50:05:07:65:05:84:09:0e 0100ef 3 50:05:07:65:05:84:0b:83 0100e8 Total devices displayed: 3 See Also fcrFabricShow, fcrProxyDevShow, fcrRouteShow, lsanZoneShow, switchShow 182 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 209
. If the configuration is altered, then care must be taken to ensure consistency across all FC Routers attached to the same edge fabric. The following information is displayed if no optional operand is given: importedFID The imported fabric ID of the proxy device. devWWN The port World Wide - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 210
device slot." is displayed if the WWN does not exist in any slot for the specified edge fabric. Examples To display the persistent proxy device configuration: switch:admin> fcrproxyconfig Imported FID 002 002 002 002 003 Device WWN 50:05:07:65:05:84:08:d7 50:05:07:65:05:84 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 211
in a fabric, the real Fibre Channel device is considered to be imported in port ID. Proxy device information is available only for proxy devices that are presented by FC Routers on the same backbone fabric as this FC Router. The default for proxy devices based on fabric ID or port WWN. "No - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 212
2 fcrProxyDevShow -w wwn Displays proxy devices with the specified port WWN. Examples To display the physical devices relevant to this FC Router: switch:admin> fcrphydevshow Device WWN Physical Exists PID in Fabric 2 10:00:00:00:c9:2b:6a:68 c70000 3 50:05:07:65:05:84:09: - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 213
is persistently stored. If the switch is disabled, phantom port WWNs are not returned to the pool until the system reboots, because the phantom switch might still be accessible through other switches. Across the switch reboot, the allocation starts from the next usable WWN base from the pool and not - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 214
WWN: WWN Pool Size Allocated 8192 3790 32768 6446 Port Limits: Max proxy devices: 2000 Max NR_Ports: 1000 Currently Used(column 1: proxy, column 2: NR_Ports): 48 | 0 0 49 | 0 0 50 | 0 0 52 | 0 0 53 | 0 0 54 | 0 0 60 | 0 0 63 | 1 4 176 | 1 4 177 | 1 4 183 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 215
load sharing over these paths. Every IFL has a default cost. For an EX-Port IFL, the default cost is 1000. For a VEX port, the default cost is 10000. If the cost is set to 0, the default cost will be used for that IFL. To set the cost, user needs to make sure that admin is enabled for - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 216
2 fcrRouterPortCost To set the cost of an EX_Port: switch:admin> fcrrouterportcost 7/10 10000 See Also switchShow, fcrRouteShow, portCfgEXPort 190 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 217
SAN. There are FC Router ports that reside on the backbone fabric. These ports configured at this FC Router. The output includes: Destination Fabric ID The destination fabric. NR_Port PID The port ID of the NR_Port. The port Switch in the Dest. Fabric The World Wide Name of the principal switch - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 218
Synopsis Description Operands Displays or persistently configures a translate (xlate) domain ID for domain ID when the translate domain is not active and is persistently saved. The principal switch attempts to provide the translate domain with the requested domain ID, but might not provide it - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 219
preferred domain ID of the translate domain created in fabric 2 that represents remote fabric 3 to a value of 8: switch:admin> fcrxlateconfig 2 3 8 xlate domain already configured, overwrite?(n) y To clear the preferred domain ID of the translate domain created in fabric 2 that represents remote - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 220
Switches can be locally configured to allow or reject a security policy. Supported policies are Switch Connection Control (SCC), Device Connection Control (DCC) Password (PWD), Fabric Configuration " that include switches running firmware versions older than v6.0. If a v5.3/5.2 switch joins a fabric - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 221
Connection Control (DCC), and Fabric Configuration Server (FCS) policies. All members specified in a given policy set s are automatically distributed to all participating switches in the fabric that support the policy. Refer to the DESCRIPTION section for specific exceptions. In the presence of - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 222
by the World Wide Name of the switch. For HBAs, only the HBA identifiers and registered port lists are displayed. No detailed HBA attributes are displayed. For registered ports, only port identifier and corresponding HBA are shown; no detailed port attributes are displayed. The execution of this - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 223
: Emulex LightPulse LP9000 1 Gigabit PCI Fibre Channel Adapter Hardware Version: 00000001 Driver Version: SLI-2 SW_DATE:May 3 2002, v5-2.11a2 **CT_TEST 1** Firmware Version: 03814101 OS Name and Version: Window 2000 Max CT Payload Length: 0x00061300 Local Port database contains: 10:00:00:00:c9 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 224
" entries are not removed from the RNID database. Examples To clear the RLIR database: switch:user> ficonclear RLIR successfully clear local RLIR Database. To clear RNID database: switch:user> ficonclear RNID successfully clear not current entries from local RNID Database. See Also ficonHelp - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 225
set FICON-CUP (Control Unit Port) parameters for a switch. All the parameters described below can be set while the switch is online. Changes to 1: POSC Programmed offline state control UAM User alert mode ASM Active=saved mode DCAM Director clock alert mode ACP Alternate control prohibited - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 226
Control Unit Port) parameters for a switch. The execution switch. modereg Display the FICON-CUP mode register. When parameter is modereg, one of the following arguments can be specified as bitname: POSC Programmed offline state control UAM User alert mode ASM Active=saved mode DCAM Director - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 227
commands. Synopsis ficonhelp Description Use this command to display a list of FICON support commands, with descriptions. Operands none Examples To display a list of FICON commands: switch:admin> ficonhelp ficonclear Clears contents of the specified FICON management database ficoncupset - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 228
port for RNID switch for RLIR is not valid. 0x50 Indicates the node ID of the channel port is not valid. Fmt Displays the record-registration format. FRU Failure Description Indicates the FRU failure type as one of the following: WWN card [unit number] Displays the WWN card number Power - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 229
Serial Number Displays the FRU serial number. Incident Count Displays the incident count. This number increases by 1 for each incident within the individual switch port state Listener PID Same as PID. Listener Port Type Same as Port Type. Listener Port WWN Displays the channel HBA port World - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 230
field for a channel port. 0x07 Terminal - Full screen if it is an storage port; otherwise, a reserved field for a channel port. 0x08 Terminal - Line mode if it is an storage port; otherwise, an emulated control unit support only. 0x09 Reserved. 0x10 Switch, if it is a switch device; otherwise - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 231
the device's channel or storage CU port World Wide Name associated with the device HBA. Sequence Number Displays the sequence number of the self describing node. Serial Number Displays the switch serial number. Switch node WWN Displays the switch node World Wide Name. Switch Port WWN Displays - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 232
remote LIRR database: switch:admin> ficonshow LIRR fabric {Fmt Type PID Listener Port WWN Switch Port WWN Listener Type 0x18 N 502b00 50:05:07:64:01:00:15: Local switch RNID database has 1 entries. To display the local RLIR database: switch:user> ficonshow RLIR { {Fmt Type PID Port Incident - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 233
: switch:user> ficonshow ILIR { {FRU Failure [2]: Power Supply[2] failure occurred on Mon Jan 13 12:11:38 2003 Fmt Protocol Domain Fabric WWN Switch WWN 0x18 FICON 80 10:00:00:60:69:33:33:33 10:00:00:60:69:80:1e:4e FRU part number: FRU serial number: 23000000602 FL2L0001071 {Listener Port - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 234
2 compliance, passwords, shared secrets and the private keys used in SSL/TLS, system login, etc. need to be zeroized. Power-up self tests will be executed when the switch is powered on to check for the consistency of the algorithms implemented in the switch. Notes Certain services and functions - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 235
Print command usage. Examples Show current FIPS configuration: switch:admin> fipscfg --show FIPS mode is : Disabled FIPS Selftests mode/status is : Disabled/None Verify FIPS prerequisites: switch:admin>fipscfg --verify fips Standby firmware supports FIPS SELF tests check has passed Root - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 236
firmwareDownload completes successfully and the CP is rebooted, the system switches the primary partition (with the old firmware) to the secondary, and the secondary partition (with the new firmware) to the primary. The default behavior of the firmwareDownload command is to automatically run the - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 237
versions. In dual-domain systems, this command by default downloads the firmware image to both CPs in rollover mode to prevent disruption to application services. This operation depends on HA support. If HA is not available, you can still upgrade the CPs one at a time, using the -s option. All - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 238
single CP mode. This mode supports selectively enabling or disabling a full install, autoreboot, and autocommit on bladed and non-bladed systems. On bladed systems, this mode supports upgrading a single CP. When downloading the main Fabric OS firmware, this option disables autoreboot, unless - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 239
CP to reset and will require that existing telnet, secure telnet or SSH sessions be restarted. Do you want to continue [Y]: y The firmware is being downloaded to the Standby CP. It may take up to 10 minutes. To download the firmware to both CPs on a Brocade DCX using a USB device: switch:admin - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 240
or IP Address: 192.168.32.10 Network Protocol (1-auto-select, 2-FTP, 3-SCP) [1]: User Name: userfoo File Name: /home/userfoo/dist/release.plist Password: To download SAS firmware without version compatibility checking: switch:admin> firmwaredownload -c Type of Firmware (FOS, SAS, or any application - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 241
reached by the switch. • user does not have permission on host. • The password for the user is not specified correctly. • Indicated firmware does not exist on the host, or is not in the right format, or is corrupted. • The FTP or SSH service is not running on host. • Platform is not supported by the - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 242
The following example shows the status of the firmwaredownload for an SAS image to the blades in slot 2 and 7. switch:admin> firmwaredownloadstatus [1]: Thu Jul 28 00:30:49 2005 Slot 2 (SAS): Firmware is being downloaded to the blade. It may take up to 30 minutes. [2]: Thu Jul 28 00:30:49 2005 Slot - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 243
has completed successfully. Use firmwareshow to verify the firmware versions. To display the status of a firmware download on a Brocade director: switch:admin> firmwaredownloadstatus [1]: Mon Dec 19 18:40:19 2005 Slot 6 (CP1, active): Firmware is being downloaded to standby CP. This step may take up - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 244
Slot 8 (FR4-18i): Firmware commit has started on the blade. This may take up to 10 minutes. [10]: Mon Dec 19 18:50:51 2005 Slot 8 (FR4-18i): The commit operation has completed successfully. [11]: Mon Dec 19 18:55:39 2005 Slot 5 (CP0, active): Firmware has been downloaded successfully on Standby CP - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 245
validation fails, signed firmware download will fail Refer to the Fabric OS Administrator's Guide for complete details on upgrading or downgrading firmware. Operands .none Examples To display the public key used for signed firmware validation: See Also switch:admin> firmwarekeyshow -----BEGIN - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 246
), the downloaded firmware becomes active. If you then do not want to commit the firmware and want to restore the former firmware, run be in place. Operands none Examples To restore the former active firmware image: switch:admin> firmwarerestore Restore old image to be active ... Restore both - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 247
of the storage device. Operands none Examples To display the firmware versions in a Brocade director with FA4-18 blades installed in slot 2 and 7. switch:admin> firmwareshow Slot Name Appl Primary/Secondary Versions Status 2 FA4-16 FOS v5.3.0 v5.3.0 SAS v3.0.0 v3.0.0 DMM v3.0.0 v3 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 248
the switch supports this option, from an attached USB device. A default firmware key is released as part of the firmware image and is downloaded to the switch during the firmware download process. The default key is used to download a new firmware. However, the firmware key may be changed by Brocade - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 249
34 User Name: johndoe File Name: /pub/dist/pubkey.pem Network Protocol(1-auto-select, 2-FTP, 3-SCP) [1]: Password: Updating the public key, please wait... Public key successfully updated. To update the public key from an external USB device: switch:admin>Firmwarekeyupdate -U /usb/usbstorage/brocade - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 250
This command has the following operands: -e |--enable feature Enables a feature on the switch. Valid values for feature are: fcr The FC Routing service will be enabled on this switch. The FC Routing service is by default disabled. Use fosConfig --show to determine the state of the FC Routing - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 251
can be run while the switch state is "online". The iSNSC service will be disabled on this switch. This command can be run while the switch state is "online". Displays the current operating status of features on the switch. Notes The features shown here may not be supported on all platforms. If you - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 252
to guide the user in supported value, specifying the replacement of the WWN card. Examples To replace the World Wide Name card: switch a power cycle, or CP failover, please follow the recovery procedure in Core Switch WWN frureplace command and follow the instructions to complete the operation. - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 253
if the domain of the local switch is currently confirmed. Bit map of all the ISL. Bit positions correspond to the default areas of the ports. Bit 0 refers to default area of the switch, bit 1 refers to default area 1, and so forth. Bit map of all the trunk slave ports. Bit map of all the Fx_Ports - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 254
2 fspfShow version = 2 domainID = 131 switchOnline = TRUE domainValid = TRUE isl_ports[0] = 0x00000000 isl_ports[1] = 0x74000000 trunk_ports[0] = 0x00000000 trunk_ports[1] = 0x02000000 f_ports[0] = 0x00400000 f_ports[1] = 0x00000000 seg_ports[0] = 0x00000000 seg_ports[1] = - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 255
fwalarmsfilterset [mode] Description Use this command to configure alarm filtering for Fabric Watch. By turning off default value is 0 (alarms deactivated). This operand is optional. Examples To enable alarms in Fabric Watch: switch:admin> fwalarmsfilterset FW: Alarms are already disabled switch - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 256
that may be in place. Operands none Examples To display the status of alarm filtering in Fabric Watch: switch:user> fwalarmsfiltershow FW: Alarms are enabled switch:user> fwalarmsfiltershow FW: Alarms are disabled See Also fwAlarmsFilterSet 230 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 257
subject to Admin Domain restrictions that may be in place. Operands none Examples To initialize all classes under Fabric Watch: switch:admin> fwclassinit fwClassInit: Fabric Watch is updating... fwClassInit: Fabric Watch has been updated. See Also fwConfigReload, fwConfigure, fwShow Fabric OS - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 258
used after downloading a new Fabric Watch configuration file from a host. This command requires a Fabric Watch license. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To reload the saved Fabric Watch configuration: switch:admin - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 259
command can be used to disable or enable all thresholds associated with a given port. This command requires a Fabric Watch license. Not all platforms support fans or power supplies. If you attempt to configure values for these items, an "ERROR: No threshold available" error message is displayed - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 260
class Same as Port class Invalid CRCS Invalid CRCS RX Performance TX Performance Filter Performance Monitor Customer Defined Security Resource Telnet Violations HTTP Violations API Violations RSNMP Violations WSNMP Violations SES Violations MS Violations Serial Violations Front Panel Violations - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 261
Customer Defined Flash Not all platforms support fans or power supplies. If you attempt to configure values for these items the following displays port. --disable --port portNumber Disables all thresholds associated with a certain port. Examples To configure thresholds in Fabric OS mode: switch: - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 262
1: switch:admin> fwConfigure --disable --port 1 To configure thresholds in Access Gateway mode: switch:admin> fwconfigure 1 : Environment class 2 : SFP class 3 : Port class 4 : F/FL Port (Optical) class 5 : Resource class 6 : quit Select a class => : (1..6) [6] 1 1 : Temperature 2 : Fan 3 : Power - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 263
1 : refresh 2 : disable a threshold 3 : enable a threshold 4 : advanced configuration 5 : return to previous page Select choice => : (1..5) [5] 5 See Also fwClassInit, fwConfigReload, fwShow fwConfigure 2 Fabric OS Command Reference 237 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 264
switch:admin> fwfrucfg The current FRU configuration: Alarm State Alarm Action Slot 0 1 Power Supply 0 0 Fan 0 0 WWN 0 0 Note that the value 0 for a parameter means that it is NOT used in the calculation Configurable Alarm States are: Absent-1, Inserted-2, On-4, Off-8, Faulty-16 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 265
Fabric Watch configuration Configure FRU state and notification Configure Fabric Watch Email Alert Create a report with detailed port information Show availability monitor information Set port persistence time Set boundary & alarm level to custom Set boundary & alarm level to default Show thresholds - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 266
Use this command to display or modify the configuration and status of the Fabric Watch email alert in the switch. Switch elements monitored by Fabric Watch are divided into classes, and email alerts are based on the classes. Each class can configure one email address as the alert message's receiver - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 267
5 : E-Port class 6 : F/FL Port (Optical) class 7 : Alpa Performance Monitor class 8 : End-to-End Performance Monitor class 9 : Filter Performance Monitor class 10 : Security class 12 : FRU Class 13 : Quit Select an item => : (0..13) [11] 1 Mail To: [NONE] [email protected] Email Alert configuration - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 268
user specified ports. The output of this command is different for IPv4 and IPv6 addresses. The overall status is calculated based on the following contributors: Port : --p portNumber Yields a port detail report for a specific user port. --s portState Yields a port detail report for the specified - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 269
based on all healthy ports m Report based on all marginal ports f Report based on all faulty ports o Report based on all offline ports If no option is specified, all ports are displayed. Examples To retrieve a port detailed report for a switch configured with an IPv6 address: switch:user - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 270
2 fwPortDetailShow See Also 001 F HEALTHY 409:09 014 F HEALTHY 409:09 015 E HEALTHY 409:09 switchStatusShow 244 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 271
to Admin Domain restrictions that may be in place. Operands none Examples To display port summary information on an eight port switch: switch:user> fwsamshow Total Total Down Total Port# Type Up Time Down Time Occurrence Offline Time (Percent) (Percent) (Times) (Percent) 0 U_PORT - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 272
time can be set with this option. Port persistence time is the time period in which a port must be persistently in a state before being actually being recognized as such. Examples To set message levels and port persistence time: switch:user> fwset --port --persistence 18 See Also fwShow 246 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 273
execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To set alarm levels to custom values: switch:admin> fwsettocustom Committing configuration...done. See Also fwSetToDefault Fabric OS Command Reference 247 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 274
. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To return alarm levels to default values: switch:admin> fwsettodefault Committing configuration...done. See Also fwSetToCustom 248 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 275
's Guide. In Access Gateway mode, only the following class thresholds are supported. F/FL Port (Copper) class threshold is supported only for a fan in the SFP class: switch:user> fwshow 1 : Show class thresholds 2 : Detail threshold information 3 : Show port persistence time 4 : Quit Select an item - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 276
3 : Power Supply 4 : return to previous page Select an area => : (1..4) [4] 2 Name Label Last value envFan001 Env Fan 1 2576 RPM envFan002 Env Fan 2 2518 RPM envFan003 Env Fan 3 2481 RPM switch:user> fwshow 1 : Show class thresholds 2 : Detail threshold information 3 : Show port - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 277
5 occurred 1 time, last at 16:30:23 on 12/09/2011 Callbacks: No callbacks are registered. To show port persistence time: switch:admin> fwshow --port --persistence FW: current port persistence time = 18s switch:user> fwShow --disable --port Port Threshold Status 1 disabled To display - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 278
commands typed into the shell; the oldest commands are replaced as new ones are entered. Operands none Examples To display previous shell commands: switch:admin> h 1 version 2 switchshow 3 portdisable 2 4 portenable 2 5 switchshow See Also none 252 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 279
Use this command to disable the High Availability feature in the switch. If the HA feature is already disabled, this command does Operands none Examples To disable the High Availability feature: switch:admin> hadisable HA is disabled See Also haEnable Fabric OS Command Reference 253 53- - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 280
running, but the background health diagnostic has discovered a problem with the blade. The logs should be checked to determine the appropriate the failover would be disruptive. IP and Fibre Channel addresses configured for the switch. Additional internal HA state information, subject to change - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 281
SWITCH Ethernet IP Address: 10.32.227.64 Ethernet Subnetmask: 255.255.240.0 Fibre Channel IP Address: 220.220.220.64 Fibre Channel Subnetmask: 255.255.240.0 CP0 Ethernet IP Address: 10.32.227.66 Ethernet Subnetmask: 255.255.240.0 Host Name: cp0 Gateway IP Address: 10.32.224.1 CP1 Ethernet IP Address - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 282
Use this command to enable the High Availability feature in the switch. If the HA feature is already enabled, this command does nothing To enable the High Availability feature in the switch: switch:admin> haenable HA is enabled See Also haDisable 256 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 283
: switch:admin> hafailover Local CP (Slot 7, CP1): Active, Warm Recovered Remote CP (Slot 6, CP0): Standby, Healthy HA enabled, Heartbeat Up, HA State synchronized Warning: This command is being run on a redundant control processor(CP) system, and this operation will cause the active CP to reset - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 284
down, or Health Monitor detects a configuration file error. • HA synchronization status Notes This command may not be supported on non-bladed systems. The execution of this command switch:admin> hashow Local CP (Slot 6, CP1): Active, Cold Recovered Remote CP (Slot 5, CP0): Non-Redundant switch: - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 285
See Also haDisable, haEnable, haFailover haShow 2 Fabric OS Command Reference 259 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 286
. The execution of this command is subject to Admin Domain restrictions that may be in place. Examples To enable the HA state synchronization: switch:admin> hasyncstart HA State synchronization has started See Also haFailover, haShow, haSyncStop 260 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 287
execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To disable the HA state synchronizing process: switch:admin> hasyncstop See Also haFailover, haShow, haSyncStart Fabric OS Command Reference 261 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 288
commands. The list displays only commands that are available to the current user; command availability may vary depending on: • Login user role • License key • Hardware platform To access help information for a specific command, enter the command name as an operand. Operands This command has - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 289
line of each record contains the following: Object type On standalone platforms: FAN, POWER SUPPLY, WWN (WWN card), or UNKNOWN. On chassis-based platforms: CHASSIS, FAN, POWER SUPPLY, SW BLADE (port blade), CP BLADE (control processor), WWN (WWN card), or UNKNOWN. Object number Slot number for - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 290
on the HW platform: The Brocade 48000 Director supports 100 history log entries. The DCX Data Center Backbone Director supports a maximum log size of 50 history mode, the user will be prompted to clear the log. Examples To display the mode of the history log: switch:admin> historymode History - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 291
line of each record contains the following: Object type On standalone platforms: FAN, POWER SUPPLY, WWN (WWN card), or UNKNOWN. On chassis-based platforms: CHASSIS, FAN, POWER SUPPLY, SW BLADE (port blade), CP BLADE (control processor), WWN (WWN card), or UNKNOWN. Object number Slot number for - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 292
Tue Aug 14 13:53:40 2001 Factory Part Number: 60-0001532-03 Factory Serial Number: 1013456800 CP BLADE Slot 6 Inserted at Tue Aug 14 13:59:50 2001 Factory Part Number: 60-0001604-02 Factory Serial Number: FP00X600128 POWER SUPPLY Unit 2 Inserted at Tue Aug 14 15:52:10 2001 Factory Part Number - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 293
which the plug-in can be downloaded. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To display the Java plug-in version: switch:admin> httpcfgshow Current HTTP configuration javaplugin.version = 1,3,1 javaplugin.homeURL = http - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 294
this command to display information about all of the processes or about a specific process if a process ID is supplied. One line is displayed per calls FORKNOEXEC 040 forked but did not exec SUPERPRIV 100 used super-user privileges DUMPCORE 200 dumped core SIGNALED 400 killed by a signal S - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 295
the following operand: processID Specifies the process name or process ID for the process to display. Examples To display information about process ID 433: switch:admin> i 433 F S UID PID PPID C PRI NI ADDR SZ WCHAN TTY TIME CMD 000 S 0 433 1 0 69 0 - 1283 5c64 ? 00:00:02 fabricd See Also - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 296
negotiation, you can choose the specific link operating modes that are serial console port. When used through an interface other than the serial console port, the command displays a warning message and prompts the user the serial console port, follow this scenario for the ifModeSet command: switch: - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 297
] y Committing configuration...done. To force the link for the eth0 interface from auto-negotiation to 10 Mbit/sec half-duplex operation, when entering this command through the serial console port: switch:admin> ifmodeset eth0 Auto-negotiate (yes, y, no, n): [yes] n Force 100 Mbps / Full Duplex (yes - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 298
eth0, where eth is the network interface and 0 is the physical unit. Examples To display the link operating mode for the "eth0" Ethernet interface: switch:admin> ifmodeshow eth0 Link mode: negotiated 100baseTx-HD, link ok MAC Address: 00:60:69:D0:24:40 See Also ifModeSet 272 Fabric OS Command - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 299
number. masterPort Port number of the trunk master port, if present, of the trunk group of which this port is a part. defaultCost Default cost of route traffic to other switches. state Current state of this interface. This E_Port is used to route traffic to other switches only if the state - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 300
. When this timeout expires, a Hello frame is sent to the neighbor switch through this port. rXmitTo Retransmission timeout value, in milliseconds. It is used to transmit topology information to the neighbor switch. If no acknowledgement is received within this value, the frame is retransmitted - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 301
for all ports on the switch (including non-E_Ports). Examples To display FSPF interface information: switch:user> interfaceshow 1/4 nbstFull = Apr 02 20:01:44.512 delay = 1 lastScn = 16 &dbRetransList = 0x1008c6a0 &lsrRetransList = 0x1008c6c4 &lsrAckList = 0x1008c6e8 inactTID = - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 302
2 interfaceShow lsrRtxTID = 0x1008c848 inactTo = 80000 helloTo = 20000 (continued on next page) rXmitTo = 5000 nCmdAcc = 7 nInvCmd = 0 nHloIn = 2 nInvHlo = 0 nLsuIn = 2 nLsaIn = 3 attHloOut = 2 nHloOut = 2 attLsuOut = 3 nLsuOut = 3 attLsaOut = 2 nLsaOut = 2 See Also - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 303
Brocade switch interoperability with McDATA switches within a Brocade fabric. Fabric OS v6.0 introduces a new M-EOS compatible McDATA Open Fabric Mode (interopMode 3) on all platforms that support McDATA Fabric Mode (interopmode 2). Open Fabric Mode is intended specifically for adding FOS-based - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 304
a McDATA OUI. The Brocade OUI will be used. However, upgrading from FOS 5.2.1_NI to FOS 6.0.0 will be non-disruptive, preserving the McDATA OUI and the given interopMode. Unless the switch is taken offline, and the interopMode is changed, or the OUI is changed with the configure command, the McDATA - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 305
effect. Do you want to continue? (yes, y, no, n): [no] y To enable McDATA Open Fabric mode on a disabled switch: switch:admin> interopmode 3 McDATA Open Fabric mode is enabled The switch effective configuration will be lost. The system will reboot to allow the change to take effect. Do you want to - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 306
this command to turn off the IOD option. The IOD option is turned off by default; however, if the IOD option was turned on using iodSet, this command can be Operands none Examples To turn off the IOD option: switch:admin> iodreset switch:admin> iodshow IOD is not set See Also iodSet, iodShow 280 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 307
, frames are always delivered in order, even when the traffic between switches is shared among multiple paths. However, when topology changes occur in are not delivered out-of-order, even during fabric topology changes. The default behavior is for the IOD option to be off. This command should be - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 308
Use this command to display whether the IOD option is enabled or disabled. Operands none Examples To display the current setting of the IOD option: switch:admin> iodshow IOD is not set See Also iodReset, iodSet 282 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 309
on all platforms that support IPv6 addresses. The --add option configures a single static IPv6 address and prefix for the specified managed entity (switch, CP, BP, or AP). The --delete option deletes a static IPv6 address and prefix for the specified managed entity. On a chassis-based platform, the - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 310
Guide. This command has the following operands: When used interactively to configure IPv4 addresses on a chassis-based based system, specify CP or logical switch. Valid values for number are 0 or 1. On platforms with blade processors, the following additional command line options are supported - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 311
and prefix on a chassis-based system: switch:admin> ipaddrset -cp 0 -ipv6 --add 1080::8:800:200C:417A/64 To delete any existing IPv6 address and prefix on CP 0 of a chassis-based platform: switch:admin> ipaddrset cp 0 -ipv6 --delete To configure a local IPv4 Ethernet address on a Brocade FC4-16E in - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 312
IP address, Ethernet subnetmask, Fibre Channel IP address, and Fibre Channel subnetmask. For CPs, the command displays the Ethernet IP address, Ethernet subnetmask, host name, and gateway IP address. For chassis based systems with intelligent blades the addresses configured for each slot can be - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 313
--addrule policyname -rule rule_number -sip source IP -dp dest port -proto protocol -act permit | deny --delrule policyname -rule in the defined configuration or active configuration. Excluding the default policies, there can be maximum six policies in the defined configuration and one policy per - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 314
its default state. An IP filter policy without any rule cannot be activated. This operand prompts for a user confirmation before filter policy is not saved to persistent configuration until a save or activate is run. The following arguments are supported with the --addrule option: -sip Specifies - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 315
port number, a range of port numbers, or a service name IP filter policy is not saved to persistent configuration until a save or activate is run. -- new rule to the specific policy and specify the source IP address, destination port number, and to permit the rule: switch:admin> ipfilter -- - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 316
2 iscsiCfg iscsiCfg Configures or displays iSCSI entities. Synopsis iscsicfg create auth -u username -s CHAP_secret [-h] iscsicfg --modify auth -u username -s CHAP_secret [-h] iscsicfg --delete auth -u username [-h] iscsicfg --clear auth [-h] iscsicfg --show auth [-u - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 317
enabled switches and blades in the fabric. Changes will not take effect until a --commit all command is issued. Make all necessary configuration changes Displays the username and status for the specified user. If username is not specified, all users in the database are displayed. tgt iSCSI virtual - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 318
-way or mutual CHAP is enforced, based on the login frame from the host. --addusername tgt -t target_name -u user_list [-h] Binds user names defined in AUTH database to the specific target. --deleteusername tgt -t target_name -u user_list [-h] Unbinds user names defined in AUTH database from the - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 319
. Actions on initiator are: --clear initiator [-h] Clears the iSCSI initiator database. --show initiator [-i initiator_name][-h] Displays all iSCSI initiators that the switch is aware of. If an initiator has attempted discovery or logon to a target, it will be displayed here. If initiator_name is - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 320
/Defined Name: State/Status: iqn.2222-23.com.brocade:21:00:00:20:37:df:83:fc Online/Committed To delete a target entry: switch:admin> iscsicfg --delete tgt -t iqn.2005-10.com.brocade.tgt1 The operation completed successfully. To bind user CHAP to a target: 294 Fabric OS Command Reference - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 321
admin> iscsicfg --addusername tgt-t iqn.2005-10.com.brocade.tgt1 -u user1 The operation completed successfully. To unbind user CHAP from a target: switch:admin> iscsicfg --deleteusername tgt -t iqn.2005-10.com.brocade.tgt1 -u user1 The operation completed successfully. To clear the target database - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 322
myddset -d mynewdd The operation completed successfully. To display the iSCSI-aware switches and their operational states (Displays switches that are capable of propagating iSCSI data base): switch:admin> iscsicfg --show fabric Switch ID Switch WWN Switch State iSNSC * 1 10:00:00:60:69:e4:20:1e - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 323
found: 1 Name iqn.1991-05.com.brocade:initiator1 IP Address 172.16.14.101 switch:admin> iscsicfg --show initiator -i iqn.1991-05.com.brocade:initiator1 Initiator details are: Name IP Address iqn.1991-05.com.brocade:isi154116.englab.brocade.com 172.16.14.101 No. of targets currently accessible - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 324
to test. By default, all the GE ports in the specified slot slotnumber will be used. This number will be between 0 and 7. 8 will mean all ports. Examples To run iscsichiptest: switch:admin> iscsichiptest --slot 7 -unit 1 -testtype 0 Running iscsichiptest Test Complete: iscsichiptest Pass 1 of - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 325
and operands: -fclunquery [-w wwn | -s] -iscsiportcfg -h -iscsiportcfg --clearstats slot/geport Clears the statistics on the port and closes the session. -iscsiportcfg --default slot/geport -iscsiportcfg --show slot/geport [-v] -iscsiportcfg --modify slot/geport options Following are the - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 326
2 iscsiHelp switch:admin> iscsihelp fclunquery Display a list of LUNs of FC target(s). fosconfig Enable/disable FabOS services iscsicfg Manage/display all iscsi configuration including authentication/virtual targets/discovery domains. iscsiportcfg Manage/display iscsi protocol related port - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 327
ASIC FC Serdes loopback. 5 FC frames from network processor to serial loopback at iFlipper FC serdes. 6 FC frames from network processor number of frames has been transmitted on each port. The default value is 100. Examples To run iscsipathtest: switch:admin> iscsipathtest --slot 2 -path 2 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 328
, 8192, 16384, and 32768. --clearstats Clears port-level iSCSI statistics on the specified port. --default Resets the port to the default values. See the "Description" section for the list of default values. --show Displays port-level protocol parameters, statistics, and session information on - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 329
supports FC4-16IP blades in Brocade 48000 directors. geport -h Specifies the port number of a GbE port to be configured in the specified slot. Use -h on any option to display the help text for it. Examples To modify the port parameters: switch Set: iSCSI LUN Reset: iSCSI Target Reset: 211 32592 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 330
2 iscsiPortCfg See Also iSCSI Task Reassign: Non FCP in PDU: Non FCP in Octet: Non FCP out PDU: Non FCP out Octet: Session details: Session Number: iSCSI Session Type: Initiator Name: Target Name: ISID: fosConfig, iscsiCfg, iscsiSessionCfg 0 17 2576 17 1352 1 Normal iqn.1991-05.com.microsoft:win- - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 331
brocade:2f:df:00:06:2b:0d:10:b9 Session type Init. Session ID Tgt. Session ID Initiator IP Num. Conns . Normal 0x400001370000 1025 30.50.1.115 1 TCP Connection Details Index TCP Port Leading Connection Switch Port outstanding R2T 1 16 Fabric OS Command Reference 305 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 332
time to retain Default time to wait Error recovery level Initial R2T 20s 2s 0 Abort Task: 0 iSCSI Abort Task Set: 0 iSCSI Clear ACA: 0 iSCSI Clear Task Set: 0 iSCSI LUN Reset: 0 iSCSI Target Reset: 0 iSCSI Task Reassign: 0 Non FCP in PDU: 0 Non FCP in Octet: 0 Non FCP out PDU: - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 333
the connection redirection for iSCSI blades on the switch: switch:admin> iscsiswcfg --showconn -s all Number of records found: 1 Slot ICR Status 3 Disabled To display a target name prefix: switch:admin> iscsiswcfg --showgw Target name is: iqn.2002-12.com.brocade To change a target name prefix - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 334
switch link (ISL) of each port on this switch. The node WWN, domain ID, and switch Examples To display the ISL connections for the switch: switch:user> islshow 1: 33-> 29 10:00:00:60 TRUNK 6:162->160 10:00:00:60:69:e2:09:fa 7:208-> 16 10:00:00:05:1e:37:02:73 3 Termonator8 4 Dazzler_1 15 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 335
only supports Brocade FC4-16IP blades in Brocade 48000 directors. -s server_ip Specifies the IP address in dotted-decimal form. Examples To set the IP address of an external iSNS server with an attached GbE port: switch:admin> isnsccfg --set 7/ge0 -s 192.168.131.124 iSNS client configuration - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 336
2 isnscCfg See Also To register the iSNS objects: switch:admin> isnsccfg --reregister Initiated re-register of iSNS objects with iSNS server To clear the IP address of iSNS server: switch:admin> isnsccfg --clear Cleared iSNS server configuration. none 310 Fabric OS Command Reference 53-1000599- - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 337
the same ports on a 16-port/blade system. On that same system, "1/0, 16, 32" is not a valid list: even though it is legal syntax, the ports do not exist. • If no slot number is specified, all lists except user port lists will use the default slot 0. • No list type except for user port lists might - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 338
is one of those shown in the table. TABLE 16 Object Descriptions Type Grouping Description BPORTS UPORTS QUADS CHIPS MINIS SLOTS INDEX Blade Switch Blade Blade Blade Chassis n.a. Blade ports, internal and external ports User ports, ports with external connections Quadrants, group of (normally - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 339
it lists all the current telnet and serial port login sessions. It lists information such as switch:admin> killtelnet Collecting login information....Done List of telnet sessions (3 found) Session No USER TTY IDLE FROM LOGIN@ ~ 0 root0 ttyS0 1:17m - 5:13pm 1 admin0 pts/0 16 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 340
. Some features of the switch and the fabric to which it is connected are optional, licensed products. Without a license installed for such products, their services are not available. A license key is a string of approximately 16 upper- and lowercase letters and numbers. Case is significant. The - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 341
Domain restrictions that may be in place. Operands none Examples To display license commands: switch:admin> licensehelp licenseadd licensehelp licenseidshow licenseremove licenseshow Adds license keys to switch Print license help info Displays the system license ID Removes a license key from - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 342
the switch and the fabric are optional, licensed products. Without a license installed for such products, the services provided by switches to use these products. The chassis is assigned a license ID from which a license is generated. Such licenses are locked and are only functional on the specific - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 343
1 POD license is installed Dynamic POD method is in use 15 port assignments are provisioned for use in this switch: 10 port assignments are provisioned by the base switch license 5 port assignments are provisioned by the first POD license * 5 more assignments are added if the second POD license - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 344
are assigned to the first POD license Ports assigned to the base switch license: 0, 1, 2, 3, 4, 5, 6, 7, 15, 16 Ports assigned to the first POD license: 8, 9, 17, 18, 19 Ports assigned to the second POD license: 10, 11, 12, 13, 14 [Note: these ports cannot be activated due to an insufficient number - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 345
licenseRemove Removes the license key from the system. Synopsis licenseremove "license" Description Use this command to remove an existing license key from a switch. The existing license key must be entered exactly as shown by licenseShow, including case. When the key has been entered, use the - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 346
command to display current license keys, along with a list of licensed products enabled by these keys. The message "No license installed on this switch" is displayed when no licenses are installed. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 347
bandwidths. Table 16 lists the link cost defaults. TABLE 17 Link Cost Defaults Link type default, "static" cost for any port except EX/VEX ports. (Use fcrRouterPortCost to configure EX/VEX ports). When executed without arguments, this command displays the current cost of each port on the switch - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 348
to the specified port number. If cost is 0, this port will then revert to its default link cost. This operand is optional. If omitted, this command displays the cost of the specified port. If no operands are specified, the current link costs for all ports on the switch. Examples To display - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 349
that session is left open. This command allows you to access commands that you cannot access at your current user level. Operands none Examples To log in as admin from the login user: switch:user> login login: admin Password:xxxxxx See Also logout Fabric OS Command Reference 323 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 350
out from a shell session. Synopsis logout Description Use this command to log out from a shell session. Remote login connections are closed and the local serial connections return to the login prompt. The exit command is accepted as a synonym for logout, as is Ctrl-D at the beginning of a line - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 351
LSAN zone. The default output displays only WWNs of the zone members. Search parameters -f, -w, and -z allow searching for LSAN zones based on fabric ID, WWN zones in the specified fabric. -w wwn Displays LSAN zones containing the specified port WWN. The WWN format is xx:xx:xx:xx:xx:xx:xx:xx. - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 352
:68 21:00:00:20:37:18:22:55 50:05:07:65:05:84:0b:83 50:05:07:65:05:84:09:0e switch# fcrFabricShow, fcrPhyDevShow, fcrProxyDevShow, fcrRouteShow, switchShow 326 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 353
are two types of database entries: 1. The link state database entry, which is permanently allocated. 2. The link state record (LSR), which is allocated when a switch is connected to the fabric. The LSR describes the links between connected domains in a fabric. For a link to be reported in the LSR - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 354
of the switch on the other side of the link. Port number on the local switch. Port number of the port on the other side of the link. Cost of this link. The default cost for State Record: Link State Record pointer = 0x10053d18 lsAge = 16 reserved = 0 type = 1 328 Fabric OS Command Reference - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 355
port = 32, rem port = LinkId = 2, out port = 33, rem port = LinkId = 2, out port = 34, rem port = LinkId = 2, out port = 35, rem port = LinkId = 2, out port = 44, rem port = LinkId = 2, out port = 45, rem port = LinkId = 2, out port = 46, rem port = LinkId = 2, out port = 47, rem port = 48 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 356
in kilobytes. -m Specify to display memory usage in megabytes. By default, memory usage is displayed in bytes. Examples To view the memory usage: switch:admin> memshow total used Mem: 129740800 112562176 Swap: 0 0 switch:admin> memshow -m total used Mem: 123 107 Swap: 0 0 free - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 357
full speed. Synopsis minicycle [--slot slotnumber][-nmegs count][-lb_mode mode][-spd_mode mode][-splb_mode 0 | 1] [-ports itemlist steps: 1. Clear port statistics and error counters. 2. Enable ports for specified self-loopback mode. 3. Configure the routing table so that when port M receives frames - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 358
ports. b. All ports are eventually marked bad. c. The user are reset for the fiber cable switch are faulty. Operands The following operands are optional: --slot slotnumber Specifies the slot number the diagnostic will operate on. The ports specified are relative to this slot number. The default - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 359
the blade ports in the specified slot (--slot) are used. Refer to itemlist for further details. If all ports in the ASIC pair are not specified, only paths between selected ports are tested. ASIC-pair 0: -ports 0-15 ASIC-pair 1: -ports 16-31 ASIC-pair 2: -ports 32-47 ASIC-pair 3: -ports 48-63 To - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 360
Complete: minicycle Pass 1 of 1 Duration 0 hr, 1 min & 4 sec (0:1:4:409). passed. To run a functional test on ports 0, 1, 2, and 8 using port loopback: switch:admin> minicycle -ports 0,1,2,8 -lb_mode 1 Back Plane Loop Back mode is ON. Running mini Cycle One moment please ... Path 0 ... Spinning - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 361
LESSN_STATUS_ERR MBUF_STATE_ERR MBUF_STATUS_ERR NO_SEGMENT PORT_ABSENT PORT_DIED PORT_ENABLE PORT_M2M PORT_STOPPED PORT_WRONG RXQ_FRAME_ERR RXQ_RAM_PERR STATS STATS_C3FRX STATS_FRX STATS_FTX TIMEOUT XMIT Refer to the Fabric OS Message Reference for more information. See Also itemList, - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 362
slotnumber -all Specifies the slot on which to operate. The default is 0 and designed to operate on fixed-port-count products. Examples To display all index 1 ASIC pair properties: switch:user> minispropshow 1 -all slot: 1, miniS: 0 [2/16] (be,5) (be,4) (be,3) (be,2) (be - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 363
switch in the fabric: switch:admin> mscapabilityshow Switch WWN Capability Switch Name 10:00:00:60:69:20:15:71 0x0000008f "switch1"* 10:00:00:60:69:00:30:05 0x0000008f "switch2" Capability Bit Definitions: Bit 0: Basic Config Service Supported. Bit 1: Platform Management Service Supported - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 364
Use this command to configure the MS ACL. MS allows a SAN management application to retrieve and administer the fabric and interconnect elements, such as switches. This application is located at the Fibre Channel well-known address, 0xFFFFFA. If the MS ACL is empty (default), MS is available to - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 365
msConfigure 2 done ... See Also msCapabilityShow, msPlatShow, msPlClearDB, msPlMgmtActivate, msPlMgmtDeactivate, msTdDisable, msTdEnable, msTdReadConfig, secPolicyShow Fabric OS Command Reference 339 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 366
to Admin Domain restrictions that may be in place. Operands none Examples To display the MS platform database for a fabric: switch:admin> msplatshow Platform Name: [9] "first obj" Platform Type: 5 : GATEWAY Number of Associated M.A.: 1 Associated Management Addresses: [35] "http://java.sun.com - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 367
command is subject to Admin Domain restrictions that may be in place. Operands none Examples To display the MS platform service database control block: switch:admin> msplatshowdbcb Domain Worldwide Name Retry Count Exchange Status 3: 10:00:00:60:69:51:10:e6 0 0x2 msPlDBCB.peerWwn - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 368
restrictions that may be in place. Operands none Examples To clear the MS platform database: switch:admin> msplcleardb MS Platform Service is currently enabled. This will erase MS Platform Service Database in the entire fabric. Would you like to continue this operation? (yes, y, no, n): [no - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 369
in the fabric boot with the MS platform service enabled. Notes By default, the MS platform service is disabled. Before issuing, run the msCapabilityShow command to verify all switches in the fabric support MS platform service; otherwise, the command fails. When FCS policy is enabled, this command - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 370
be in place. Operands none Examples To deactivate the MS platform service on all switches in the fabric: switch:admin> msplmgmtdeactivate MS Platform Service is currently enabled. This will erase MS Platform Service configuration information as well as database in the entire fabric. Would you - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 371
Use this command to disable the management server topology discovery service of a local switch or an entire fabric. This change takes effect immediately and commits to the configuration database for all switches; therefore, persistent across power cycles and reboots. If the "ALL" operand is used - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 372
Use this command to enable the MS topology discovery service on a local switch or on the entire fabric. This command enables the MS Topology Discovery Service. This change takes effect immediately and commits to the configuration database for all affected switches. If the operand "ALL" is used, this - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 373
restrictions that may be in place. Operands none Examples To display the status of the topology discovery service: switch:admin> mstdreadconfig *MS Topology Discovery is enabled. See Also msCapabilityShow, msConfigure, msPlMgmtActivate, msPlMgmtDeactivate, msTdDisable, msTdEnable Fabric OS - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 374
IPv4 or IPv6 addresses associated with the status of the system and the login session details. The login session gives details of the following: • CP/switch (or console/serial port) used to log in • The IP address of the current login session for telnet or the name of the current console - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 375
display information about neighbors to the local switch, or information about a specific neighbor if a port number is supplied. FSPF defines a switches directly connected to the local switch: switch:user> nbrstateshow 2/0 Local Domain ID: 1 Local Port Domain Remote Port State 16 2 48 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 376
to its slot for bladed systems. Use switchShow to list valid ports. This operand is optional; if omitted, FSPF statistics are reset. When this command is executed without operand, the statistics are cleared for all interfaces. Examples To reset the counters on a port: switch:admin> interfaceshow - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 377
Interface 0 data structure: nghbP ifNo masterPort defaultCost cost = 0x1004ce68 = 0 = 0 (self) = 500 = 500 (output truncated) nCmdAcc = 0 nInvCmd = 0 nHloIn = 0 nInvHlo = 0 nLsuIn = 0 nLsaIn = 0 attHloOut = 0 nHloOut = 0 attLsuOut = 0 nLsuOut = 0 attLsaOut = 0 nLsaOut = 0 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 378
port World Wide Name (WWN) or a node WWN matching with the given WWN; or have a device PID matching with the given PID; or have a defined configuration To display all the device information matching the alias "a320": switch:user> nodefind a320 Local: Local: Type Pid COS PortName NodeName SCR - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 379
Name: 20:00:00:e0:8b:01:ce:d3 Device type: Physical Target Port Index: 14 Share Area: No Device Shared in Other AD: No Aliases: To display all the device information matching the PID "0x020eef": switch:user> nodefind 0x020eef Remote: Type Pid COS PortName NodeName NL 020eef; 3;20:00:00 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 380
defined configuration aliases to which the device belongs. The following message is displayed if there is no information in this switch: switch Virtual Contrived device by the switch NPV Device connected to the Nx_Port, using FDISC to log in to the switch iSCSIDevice connected to the iSCSI port - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 381
has 6 entries } To display local NS information with aliases with the -r option: switch:admin> nsaliasshow -r { Type Pid COS PortName NodeName SCR N 021200; 2,3;10:00:00:60:69:00:03:19;30:00:00:60:69:00:03:19; 3 FC4s: FCIP Fabric Port Name: 20:02:00:60:69:01:44:22 Permanent - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 382
Name: 20:04:00:60:69:01:44:22 Permanent Port Name: 21:00:00:ad:bc:04:6f:70 Aliases: The Local Name Server has 6 entries } To display local NS information with aliases with the -r and -t options: switch:admin> nsaliasshow -r -t { Type Pid COS PortName NodeName SCR N 021200; 2,3;10:00:00 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 383
command to display the 24-bit Fibre Channel addresses of all devices in all switches in the fabric. If the type specific FC-PH device type codes: 8 = FCP type device 4, 5 = FC-IP type device Other FC-PH types are displayed in the format "x ports supporting FC4 code," where x is the number of ports - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 384
cache manager does not discover new switches or new devices in the fabric. For each remote switch found, the output of this Channel address COS A list of classes of service supported by the device PortName The device's port World Wide Name (WWN) NodeName The device's node WWN Permanent Port - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 385
:00:00:60:69:00:ab:ba; FC4s: FCIP PortSymb: [28] "SEAGATE ST318452FC 0001" Fabric Port Name: 20:02:00:60:69:00:68:19 Permanent Port Name: 10:00:00:60:69:00:ab:ba Switch entry for 4 state rev owner known v320 0xfffc01 Device list: count 0 No entry is found! To - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 386
The nsAllShow command displays information from all switches. Each line of output displays: Type U for unknown, N for N_Port, NL for NL_Port. PID 24-bit Fibre Channel address. COS List of classes of service supported by device. PortName Device port World Wide Name (WWN). NodeName Device - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 387
switch Virtual Contrived device by the switch NPV Device connected to the Nx_Port, using FDISC to log in to the switch iSCSI Device connected to the iSCSI port does not include device type information. After a nondisruptive upgrade from those Fabric OS versions, the device type displays - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 388
21:00:00:e0:8b:12:8a:be Port Index: 14 Share Area: No Device Shared in Other AD: No Redirect: No The Local Name Server has 2 entries } See Also To display local name server information with "-r" and "-t" options. switch:admin> nsshow -r -t { Type Pid COS PortName NodeName SCR N 010100 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 389
, N for N_Port, NL for NL_Port Pid The 24-bit Fibre Channel address COS A list of classes of service supported by the device PortName The device's port World Wide Name (WWN) NodeName The device's node WWN Permanent Port Name Physical N_Port or NL_Port WWN DeviceType The device's type - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 390
:d9:61:ac Device type: Physical Target No remote zoned members To display each local device's online zoned device data: switch:admin> nszonemember -a Port: 4 Pid: 0xb00400 Aliases: ix360_131_201_6a Zoned Members: 2 devices Pid: 0xb00400 Aliases: ix360_131_201_6a Pid: 0xba1ee8 Aliases: trimm101b_3 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 391
Pid: 0xb00e00 Aliases: dl360_130251a dl360_130251a Pid: 0xba1ae4 Aliases: trimm100a_2 To display all the unzoned devices in the fabric: switch:admin> nszonemember -u Pid: 0xb01ea9; Aliases: trimm32b_1 Pid: 0xb01eaa; Aliases: trimm32b_2 Pid: 0xb01eab; Aliases: trimm32b_3 Pid: 0xb01eac; Aliases - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 392
can be changed locally on any switch. For the password database to be distributed to other switches in the fabric, the switches must be configured to accept the password database with the fddCfg command. The password database is distributed manually with the distribute command. The execution - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 393
Changing the password of any user level causes the login session of that account (if logged in) to terminate. Examples To change the password for the admin account while logged in as admin: switch:admin> passwd Changing password for admin Enter new password: Re-type new password: Password changed - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 394
matches one of the previous passwords The password you entered matches one of the previous passwords. You must wait longer to change your password. You cannot change the password before the minimum ageing period expires. Password contains invalid characters. The password you entered contains invalid - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 395
. When a user's password expires, the user must change the password to complete the authentication process. A warning that password expiration is approaching is displayed when the user logs in. The number of days prior to password expiration during which warnings commence is a configurable parameter - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 396
--showall Displays all the password configuration parameters. --set Configures a specified password policy. The following arguments are supported: -lowercase value Specifies the minimum number of lowercase alphabetic characters that must occur in the password. The default value is 0. The maximum - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 397
0 to 999. The default value to 0. -lockoutthreshold value Specifies the number of times a user can specify an incorrect password during login before the account passwdcfg.lockoutduration" duration. The particular account is unlocked manually using userconfig --change account name-u (requires root/ - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 398
"passwdcfg.adminlockout" to 0. By default, admin lockout policy is disabled. --setdefault Resets all password policies to their default values. --help Displays command usage. Examples To display the current password configuration parameters: switch:admin> passwdcfg --showall passwdcfg - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 399
value must be between 0 and 999. warning value out of range The -warning value must be between 0 and 999. invalid password expiration specification The -minpasswordage value or -warning value must be less than or equal to -maxpasswordage value when -maxpasswordage value is nonzero. lockoutthreshold - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 400
path, or on a user selected path (source route). For each hop, the routing information output includes the following: Hop The hop number. The local switch is hop 0. In Port The port or area from which the switch receives frames. For hop 0, this is src_portnumber. For bladed systems, this is - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 401
the tracing of the reverse path is requested. The default value for the maximum hop count is 25. Basic . Words Total number of 4-byte Fibre Channel words. Frames Total number of frames. The source route option allows the user to specify a sequence of switches, ports, or areas that the pathInfo - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 402
the part described by output ports or areas. Switches running pre 5.2 firmware cannot use ports > 256 as a destination port on a remote switch. The execution of this . src_portnumber Port or area whose path to the destination domain is sought. The default is embedded port (-1). For bladed systems, - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 403
to wait for the response; default is 10 seconds. Examples To display basic path information to a specific domain, using the command line (non-interactive mode): switch:admin> pathinfo 91 Target port is Embedded Hop In Port Domain ID (Name) Out Port BW Cost 0 E 9 (web226) 2 1G 1000 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 404
2 pathInfo Hop In Port Domain ID (Name) Out Port BW Cost 2 14 8 (web228) E - - (output truncated) See Also portStatsShow, switchShow 378 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 405
switch. If a panic dump file is specified as an argument, the contents of that specific file are displayed. Operands This command has the following optional operands: panic_dump_file Specify the full WatchDogRegister=0x0 Section=Startup time: Tue Dec 3 16:06:11 UTC 2002 Kernel= 2.4.19 Fabric OS - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 406
Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports has the following operands: slotnumber For bladed systems only, this operand specifies the slot number of the port on which the monitor is to be - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 407
is required to separate the operands even when using commas. Examples To add an end-to-end monitor to blade 1 port 2: switch:admin> perfaddeemonitor 1/2 "0x050200" "0x1182ef" End-to-End monitor number 0 added. See Also perfAddIPMonitor, perfAddReadMonitor, perfAddRWMonitor, perfAddSCSIMonitor - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 408
monitor numbers and user-defined aliases can be displayed with the perfMonitorShow command. Notes This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. The execution of - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 409
be surrounded by quotation marks, in order to include spaces. This operand is optional. The default alias is "SCSI Read". . Examples To add an SCSI read monitor to a port: switch:admin> perfaddreadmonitor 2/4 "SCSI_R" SCSI Read filter monitor #2 added See Also perfAddEEMonitor, perfAddIPMonitor - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 410
of these filter-based performance monitors. The optional user-defined alias is also displayed, if one was specified. All valid monitor numbers and user-defined aliases can be retrieved with the perfMonitorShow command. The maximum number of filters is eight per port, including user-defined filters - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 411
of these filter-based performance monitors. The optional user-defined alias is also displayed, if one was specified. All valid monitor numbers and user-defined aliases can be retrieved with the perfMonitorShow command. The maximum number of filters is eight per port, including user-defined filters - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 412
Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. Bloom-based platforms provide two unique unused offsets per port for user bladed systems only, this operand specifies the slot number of the port - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 413
. This operand is optional. By default, the alias is an empty string. Examples To add a filter-based monitor for all Extended Link Service requests (R_CTL=0x22 and TYPE=0x01) to a port: switch:admin> perfaddusermonitor 1/4 "4, 0xff, 0x22; 12, 0xff, 0x01" User monitor #0 added As a special case - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 414
by quotation marks, in order to include spaces. This operand is optional. The default alias is "SCSI_Write". Examples To add an SCSI Write command monitor to a port: switch:admin> perfaddwritemonitor 2/4 "SCSI_W" SCSI Write filter monitor #0 added See Also perfAddEEMonitor, perfAddIPMonitor - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 415
to-end and filter configuration settings of performance monitoring from nonvolatile memory. Notes This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. The execution of this - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 416
memory. Any configuration changes that were not saved are lost using the perfCfgRestore command. Notes This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. The execution - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 417
on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To save the current performance monitoring configuration to firmware: switch:admin> perfcfgsave This - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 418
error counter associated with a specific port and AL_PA, or all such counters on a port. Notes This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. The execution of this - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 419
based performance monitors on a port or a filter-based monitor associated with a specific monitorId. Issuing portStatsClear on a port also results in all filter-based monitors clearing. Notes This command requires a Brocade bladed systems only, this operand specifies the slot number of the port on - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 420
to Admin Domain restrictions that may be in place. Operands This command has the following operands: slotnumber For bladed systems only, this operand specifies the slot number of the port on which the monitor is to be added, followed by a slash (/). portnumber Specifies the number of the - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 421
delete a filter-based performance monitor from a port, or all such monitors associated with a port. Notes This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. The execution - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 422
monitor for SCSI frame count Add filter-based monitor Add filter-based monitor - SCSI Write Clear Performance settings from FLASH Restore Performance configuration from FLASH Save Performance configuration to FLASH Clear filter-based monitors' counters on a port Clear ALPA device's CRC count Delete - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 423
to-end and filter-based monitors (but not ISL monitors) for all the ports in the same quad. Notes This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. The execution of this - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 424
2 perfMonitorClear To clear statistics counters for an ISL monitor: switch:admin> perfmonitorclear --class ISL 1 This will clear ISL monitor on port 1, continue? (yes, y, no, n): [no] y See Also perfAddEEMonitor, perfAddIPMonitor, perfAddReadMonitor, perfAddRWMonitor, perfAddSCSIMonitor, - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 425
monitors on a port. Monitor classes include end-to-end monitors (EE), filter-based monitors (FLT), and Inter-Switch Link monitors (ISL monitor is added using performance monitor CLIs, this field displays N/A. Frame_count Cumulative 64-bit frame count If you do not specify a value for the interval - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 426
FLT (filter-based), or ISL (interswitch link). These values are case-sensitive. slotnumber For bladed systems only, this operand specifies the slot number of the port on which 1080::8:800:200C:417A To display EE monitors configured on the switch port number using an application that passes an IPV6 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 427
52m 0 52m 0 52m 0 52m 0 To display cumulative filter monitor information on a port: switch:admin> perfmonitorshow --class FLT 2/5 There are 7 filter-based monitors defined on port 21. KEY ALIAS OWNER_APP FRAME_COUNT OWNER_IP_ADDR 0 SCSI_Frame TELNET 0x00000000002c2229 N/A 1 SCSI_WR TELNET - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 428
count for this ISL: 1462326 Number of destination domains monitored: 3 Number of ports in this ISL: 2 Domain 97: 110379 Domain 98: 13965 Domain 99: 1337982 To display EE moniors configured on port number 0: switch:admin> perfmonitorshow --class EE 0 There is 1 end-to-end monitor defined on - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 429
and the AL_PA ID address field must be masked together, to support the FC4-48 blade. On this blade, one bit of the AL_PA ID address field is used with the Area ID address field to identify the upper 32 ports. For example, ports 128 and 256 may be addressed on Domain ID "dd" with Area ID "aa - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 430
RxSIDMsk RxDIDMsk Specify the following values to turn on or off a specific field: Specifies that the field does not trigger EE monitors. Specifies that set the overall mask for end-to-end monitors on a port: switch:admin> perfsetporteemask 1/6 "00:00:00" "ff:ff:ff" "00:ff:ff" "ff - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 431
port are displayed. CRC count is a 64-bit counter. The CRC count value is displayed in hexadecimal. Notes This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on the Brocade bladed systems only, this operand specifies the slot number of the port on - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 432
This command has the following operands: slotnumber For bladed systems only, this operand specifies the slot number of the port on which the monitor is to be displayed monitors configured on the switch port 0: switch:admin> perfshoweemonitor 0 There is 1 end-to-end monitor(s) defined on port 0. - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 433
0x00000000000 RX_COUNT CRC_COUNT OWNER_IP_ADDR 0x0000000000000000 0x0000000000000000 N/A To display end-to-end monitor frame traffic on a port at an interval of every 6 seconds: switch:admin> perfshoweemonitor 4/5 6 perfshoweemonitor 53, 6: Tx/Rx are # of bytes and crc is # of crc errors - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 434
switch. Top Talker installs only on E_Ports and measures the data rate of all the possible flows in the fabric. Flow is a pair of communicating FC addresses (SID and DID). Notes The Top Talker Monitor feature requires a Brocade Advanced Performance Monitor license. All platforms supported under - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 435
flows. Valid values are between 1 and 32. If a value >32 is entered, Top Talker will display counters for only 32 flows and a warning message.This operand is to blade 1 port 2 (which should be an F_port): Switch:admin> perfttmon --add ingress 1/2 To display the F_port Top Talker output: Switch: - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 436
2 PerfTTmon 0xa905ef 0xa909d5 0xa05200 0xa05200 6.830 6.772 To delete the Fabric Mode Top Talker: Switch:admin> perfttmon --del fabricmode See Also None 410 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 437
is subject to Admin Domain restrictions that may be in place. Operands none Examples To create PKI objects: switch:admin> pkicreate Installing Private Key and Csr... Switch key pair and CSR generated... Installing Root Certificate... See Also If PKI objects already exist, the following message - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 438
:admin> pkiremove WARNING!!! Removing Pki objects will impair the security functionality of this fibre channel switch. If you want secure mode enabled, you will need to get the switch certificate again. About to remove Pki objects. ARE YOU SURE (yes, y, no, n): [no] y All PKI objects removed - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 439
of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To view PKI objects: switch:admin> pkishow Passphrase : Exist Private Key : Exist CSR : Exist Certificate : Empty Root Certificate: Exist See Also pkiCreate, pkiRemove Fabric OS - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 440
ID of the policy. Valid values are 1 to 32, and ALL with the --show option. Optional Operands -enc method 3DES AES-128 AES-256 -auth algorithm SHA-1 MD5 AES-XCBC -pfs value -dh group Specifies the encryption algorithm. The default is AES-128. Methods include: Triple data encryption standard - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 441
lifetime in seconds. A new key is renegotiated before seconds expires. seconds must be between 28800 to 250000000 or 0. The default is 28800. Examples To create a new policy: switch:admin> policy --create ike 10 -enc 3des -auth md5 The following policy has been set: IKE policy 10 Authentication - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 442
10 Authentication Algorithm: SHA-1 Encryption: AES-128 Perfect Forward Secrecy: 0 Diffie-Hellman Group: 1 SA Life (seconds): 28800 To delete a policy: switch:admin> policy ike --delete 10 The policy has been successfully deleted. See Also portCfg, portCfgShow, portShow 416 Fabric OS Command - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 443
to display, followed by a slash (/). portnumber Specify the port number to display, relative to its slot for bladed systems. Use switchShow to list valid ports. Examples To display the AL_PAs of a port: switch:user> portalpashow 4/14 AL_PA type AL_PA 0xe2 public 0xe4 type public AL_PA - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 444
user input Max/Resv Buffers The maximum or reserved number of buffers that are allocated to the port based on the estimated distance (as defined by the desired_distance operand of the portCfgLongDistance command). If the port is not configured the switch. LD mode supports distances up to 500 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 445
its slot for bladed systems. Use switchShow for a list of valid ports. Examples To display the port buffer information for a port: switch:admin> portbuffershow 17 User Port Lx Max/Resv Buffer Needed Link Remaining Port Type Mode Buffers Usage Buffers Distance Buffers 16 - - 0 - - 17 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 446
acts as a proxy for the CAM entries of the secondary port in this case using redirect filters. Examples For example port 7/31 and 7/39 are shared ports and 7/31 is primary. In this case portcamshow entries will look like below: switch:user> portcamshow 7/39 Area SID used DID used SID entries - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 447
CAM utilization for all ports on a switch: switch:user> portcamshow Ports of Slot 9 Port SID used DID used SID free DID free 0 0 0 64 512 1 0 0 64 512 2 0 0 64 512 3 0 0 64 512 4 0 0 64 512 5 0 0 64 512 6 0 0 64 512 7 0 0 64 512 8 0 0 63 511 9 0 0 63 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 448
table. • Create, modify, and delete Fibre Channel over IP (FCIP) tunnels. - Delete, reset, and modify QoS mappings on an existing tunnel. - Create or modify a tunnel with VLAN tagging and Class of Service (CoS). • Configure IP interfaces on the GbE port. • Configure static routes on the IP interface - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 449
entries can be flushed, static entries will not be cleared. fciptunnel Creates Fibre Channel over IP (FCIP) tunnels. You can configure up to a maximum of 8 FCIP tunnels per GbE port. This feature requires a Brocade FCIP license. The syntax for portcfg fciptunnel is as follows: portcfg fciptunnel - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 450
tunnels (IPSec or otherwise) can be configured on the same port. Jumbo frames will not be supported on secure tunnels. Only a single route is supported on an interface with a secure tunnel. -v vlan_id Creates an FCIP tunnel with VLAN Tagging and Class of Service (CoS). Specify a vlan_id in the - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 451
to 16; default is 8. If tape pipelining is enabled, the default value is calculated based on Service/Priority, as defined by IEEE 802.1p, for the FCIP data connection. Range is 0-7. Default is 0. delete tunnel_id Deletes specified FCIP tunnel. qosmap tunnel_id args Modifies (or resets to default - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 452
qosmap: tunnel_id Specifies the tunnel_id. Range is 0-7. -default Resets/sets VC QoS map to default values. -delete Deletes associated QoS map configuration file. Delete QoS mappings before downgrading to pre-v6.0.0 firmware versions that do not support QoS mapping. It removes the file from - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 453
IPv4 address of the virtual port. iproute Defines static IP routes on a GbE port. After defining the IP interface of the remote switch, you can define destination routes on an interface. A maximum of 32 routes per GbE port are supported. IPv6 addresses are supported on platforms running v6.0.0 or - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 454
Configures the FC port for FC Fastwrite. Enables ordisables FC Fastwrite between two Brocade 7500 routersor two Brocade 48000 directors with FR4-18i bladesconnected by Fibre Channel ISLs. FastrWrite mitigateslatency effects on SCSI writes, and improve throughputover a high-latency link. The blade - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 455
. L2 CoS Specifies L2 Class of Service/Priority, as defined by IEEE 802. Default is 0.0.0.0. ficon tunnelId Use this command to enable or disable FICON emulationin an FCIP tunnel and modify associated parameters onan FCIP tunnel on a 'virtual' E Port. This command is supported only on a Brocade - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 456
specific arguments are supported with the config and delete options. -a |--wrtMaxPipe value ' Defines the maximum number of tape write channel The value should be chosen based upon the typical tape channel program that requires optimum performance. The default value is 32. The range is 1-100 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 457
bytes) The Range is 1 Mb-5 Mb. -o |--oxidBase value Defines the base value of an entry pool of 256 OXIDs supplied to emulation generated exchanges. It should fall outside the range used by FICO channels and devices to avoid conflicts. The default value is 0x1000. The range is 0x0000 to 0xF000 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 458
> portcfg fciptunnel ge1 qosmap 1 4 -P 2 To return the VC QoS map settings to default values: switch:admin> portcfg fciptunnel ge1 qosmap 1 -default To create an FCIP tunnel with VLAN tagging: switch:admin> portcfg fciptunnel8/ge0 create 1 192.168.10.1 192.168.20.1 0 -m 20 -v 100 -p 3 -P 7 Operation - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 459
FICON Tape Write Pipelining Emulation features enabled using all default parameter arguments: switch:admin> portcfg ficon ge0 1 -x 1 -w 1 To configure FTRACE with ACo disabled and FTRACE enabled on port ge0/tunnel 3: switch:admin> portcfg ftrace ge0 3 cfg -a 0 -e 1 -p 5 -s 00000003 -t ffffffff To - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 460
2 portCfg 434 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 461
its slot for bladed systems. Use the switchShow command for a list of valid ports. mode Specify a value of 1 to set the AL_PA to 0x13. A value of 0 sets the default AL_PA of 0x0. This operand is required. Examples To configure a port with AL_PA 0x0 (default): switch:admin> portcfgalpa 1/3 0 See - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 462
the number of the port to be returned to default values, relative to its slot for bladed systems. Use switchShow to list valid ports. Examples To reset a port to factory defaults: switch:admin> portcfgdefault 1/3 To reset a GbE port to factory defaults: switch:admin> portcfgdefault 8/ge1 See - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 463
persistent across switch reboots or power cycles. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands This command has the following operands: slotnumber For bladed systems only, specifies the slot number of the port to be configured,followed by - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 464
front phantom domain to request a domain ID from the principal switch. The domain ID received becomes the subsequent preferred domain ID, which is persistent and is displayed. When the port is not active, the preferred domain ID is configurable. The preferred domain ID is used by the EX_Port's front - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 465
switch specifies in the ELP request. If the state is "Not OK", the R_A_TOV and E_D_TOV display "Not Applicable". By default, all EX_Ports are auto-ELP enabled. If the Fabric Parameter attribute value is "User configured", the port the preferred domain ID. For Brocade native mode (-m 0) or McDATA - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 466
2 portCfgEXPort Examples To display the EX_Port configuration of port 2/0: switch:admin> portcfgexport 2/0 Port 2/0 info Admin: enabled State: OK Pid format: core(N) Operate mode: Brocade Native Edge Fabric ID: 16 Front Domain ID: 160 Front WWN: 50:06:06:9e:20:9f:ce:10 Principal - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 467
persistent across switch reboots or power cycles. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands This command has the following operands: slotnumber For bladed systems only, specify the slot number of the port to be configured, followed by - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 468
This feature is not backward compatible with firmware versions that do not support it. Notes The long distance modes L0.5, L1, and L2 are no longer supported in v5.3.0 and above. Changes made by portCfgISLMode are persistent across switch reboots and power cycles. The execution of this command is - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 469
portcfgislmode 1/3, 1 ISL R_RDY Mode is enabled for port 3. Please make sure the PID formats are consistent across the entire fabric. To disable ISL R_RDY mode on a port: switch:admin> portcfgislmode 1/3, 0 See Also configure, portCfgLongDistance, portCfgShow Fabric OS Command Reference 443 53 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 470
Use this command to allocate enough full size frame buffers on a particular port to support a long distance link up to 500 Km. The port can only be used as an E_Port. Changes made by this command are persistent across switch reboots and power cycles. This configuration can be cleared but not set - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 471
is used to allocate the buffers required for the port. Notes This command requires a Brocade Extended Fabrics license. The execution of this command is with firmware versions that do not support it. Ctrl-D will cancel the configuration update. Examples To configure a switch port 63 to support a - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 472
: 0 CMI_bus_err: 0 Loss_of_sig: 9 Protocol_err: 0 Invalid_word: 0 Invalid_crc: 0 Delim_err: 0 Address_err: 0 Lr_in: 0 Lr_out: 0 Ols_in: 0 Ols_out: 0 configure, portCfgISLMode, portCfgTrunkPort, portCfgShow, portShow, switchShow 446 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 473
; if omitted; the default value of 0 is used. Private devices are supported only on Brocade 3250, 3850, and 3900 and directors with FC2-16 and FC2-16 blades. For other switches and blade types, option 1 is blocked. duplex_mode Specify 2 to configure the specified port as a full-duplex L_Port with - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 474
. To display the L_Port conditions: switch:admin> portcfglport [output from other slots suppressed] Ports of Slot 4 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Locked L_Port ON Private L_Port Locked Loop HD Loop Fairness See Also configure, portShow, switchShow 448 Fabric OS - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 475
The default value for mode is 0 (disabled) and if the value 1 (enabled). Examples To enable N_Port functionality for a port: switch:admin> portcfgnport 2 1 To enable N_Port functionality for a set of ports in a specific range: switch:admin> portcfgnport 2-3 1 To display the N_Port configuration - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 476
from 0 to 255 per port. The default value is 126 per port. The number of virtual port IDs per switch also can be configured. See configure for more information on configuring these values. Notes Changes made by this command are persistent across switch reboots and power cycles. Use the portCfgShow - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 477
Suppressed Persistent Disable NPIV capability .. .. .. ON EX Port where AN:AutoNegotiate, ..:OFF, ??:INVALID. LM:L0.5 See Also To disable NPIV functionality on a port: switch:admin> portcfgnpivport 1/3 0 configure, portCfgDefault, portCfgShow Fabric OS Command Reference 451 53 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 478
does not enable the persistently disabled ports of that blade. Notes The persistent switch disable or enable configuration does not alter the persistent disable or enable configurations of the ports within the switch. Because the default state of the port is persistently enabled, the persistent - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 479
enabled ports remain enabled across power cycles, switch reboots, and switch enables. By default, a port is enabled persistently, unless the port is capable of routing. The change in configuration is effective immediately. A persistent port enable re-enables all previously set port configurations of - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 480
to form an inter-switch link (ISL). Qos configuration is persistent across system reboots. Operands This command has the following operands: --default Applies the default Qos configuration to the specified port. QoS will be enabled by best effort based on availability of buffers. --disable - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 481
3/15 To set the ingress rate limit on a port to 2 Gbps: switch:admin> portcfgqos --setratelimit 3/15 2000 To set the default Qos configuration on a port: switch:admin> portcfgqos --default 3/15 portCfg, portCmd, portShow, switchShow, configure : PortCfgQos 2 Fabric OS Command Reference 455 53 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 482
port configuration settings for all ports on a switch, except gigabit Ethernet (GbE) ports. Additionally, use this command with optional arguments to display specific FCIP parameters configured for a gigabit Ethernet port statically be user input This value is set by the portCfgLongDistance command. - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 483
is disabled. This value is set by the portCfgNPIVPort command. It is enabled by default for Condor-based ports and disabled by default for Bloom-based ports. QOS E_Port Displays ON when Adaptive Networking/Quality of Service (AN/QoS) is enabled on an E_port. Displays (..)/OFF when QoS is disabled - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 484
qosmap Displays the VC to QoS mapping. Examples To display the port configuration settings on a chassis-based system: switch:admin> portcfgshow Ports of Slot 2 0 1 2 3 4 5 6 7 8 ON ON ON ON ON ON ON ON Mirror Port FC Fastwrite .. .. .. ON Ports of Slot 2 16 17 18 19 20 21 22 23 24 25 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 485
ON ON ON ON where AN:AutoNegotiate, ..:OFF, ??:INVALID, To display the configuration settings for a single port: switch:admin> portcfgshow 2/16 Area Number: 144 Speed Level: AUTO AL_PA Offset 13: OFF Trunk Port ON Long Distance OFF VC Link Init OFF Locked L_Port OFF Locked G_Port - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 486
Retransmissions 8 VC QoS Mapping off DSCP (Control): 10, DSCP (Data): 40 VLAN Tagging Not Configured VC QoS Map: VC DSCP L2CoS VC DSCP L2CoS VC DSCP L2CoS 0 46 7 1 07 168.60.181 Local IP Addr 192.168.60.101 Remote WWN Not Configured Local WWN 10:00:00:05:1e:39:80:65 Compression on Fastwrite - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 487
VC DSCP L2CoS 3 15 3 7 31 0 11 47 4 15 63 0 Vlantag configuration Display of VLAN tagging on a GbE port. Refer to the portCfg help page for an explanation of the displayed parameters. switch: admin> portcfgshow vlantag 8/ge0 Port: 8/ge0 IpIfAddress VlanId L2 CoS Dest IP Address Flags 192 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 488
is saved in nonvolatile memory and is persistent across switch reboots or power cycles. Notes This configuration cannot be set on VE/VEX_Ports. Use portShow to display actual port speed levels. Use portCfgShow to display user-specified speed settings. The execution of this command is subject - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 489
a port number to be configured, relative to its slot for bladed systems. Use switchShow to display a list of valid ports. mode Specify 1 to enable this port for trunking. Specify 0 to disable the port from being trunked. This operand is required. Examples To enable a port for trunking: switch - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 490
negotiated values are what the edge switch specifies in the ELP request. If the state is "Not OK", the R_A_TOV and E_D_TOV display "Not Applicable". By default, all VEX_Ports are auto-ELP enabled. If the Fabric Parameter attribute value is "User configured", the port ID format R_A_TOV and E_D_TOV - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 491
0 Brocade Native mode. 1 McDATA Open Fabric mode. 2 McDATA Fabric mode. Note that this mapping between mode values and modes is NOT the same as the mapping used when setting interoperability modes with the interopMode, command. Examples To display the VEX_Port configuration of port 2/16: switch - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 492
fabric's version stamp: N/A To set the fabric ID of port 2/21 to 5 and the port ID format to core: switch:admin> portcfgvexport 2/21 -f 5 -p 1 To configure port 2/20 to be an VEX_Port and set the fabric ID to 4: switch:admin> portcfgvexport 2/20 -a 1 -f 4 To disable fabric parameter negotiation on - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 493
from an intelligent GbE port. Notes Virtual LAN (VLAN) tagging is supported on the Brocade FR4-18i and all port options: slot For bladed systems only, specify the slot number of the port to be configured, followed by a slash (/). ge port Specifies the port number of the GbE port on the blade - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 494
end IP path performance based on the data rate configured for a tunnel between Service Specifies Class of Service/Priority, as defined by IEEE 802.1p. Values must be in the range between 0 and 7. The default header and payload. Note: There is limited support for black hole PMTU detection. If the - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 495
a fixed size in bytes. The default is 64 bytes. In an IPv4 environment, the ICMP/IP header occupies 28 bytes. In an IPv6 environment. it occupies 48 bytes.The total size, including ICMP/IP headers (28 or 48 bytes without IP options) cannot be greater than the IP MTU configured on the interface. This - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 496
route packet to use. The default is 64 bytes. In an IPv4 environment, the ICMP/IP header occupies 28 bytes. In an IPv6 environment. it occupies 48 bytes.The total size, including ICMP/IP headers (28 or 48 bytes without IP options) cannot be greater than the IP MTU configured on the interface. This - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 497
Specify the debug level to be set for port modules; valid values are 1 to 5. vbs_lvl Specify the verbose level to be set for port modules; valid values are 1 to 5. Examples To set debug level and verbose level of port modules: switch:admin> portdebug 3 4 See Also dbgShow Fabric OS Command - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 498
only, specify the slot number of the port to be configured, followed by a slash (/). portnumber Specify a port number to be disabled, relative to its slot for bladed systems. Use switchShow to display a list of valid ports. Examples To disable a port: switch:admin> portdisable 2/4 See Also - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 499
indicate a state transition: RSCN, SNMP trap, Web pop-up window. This command is rejected if the port's switch is disabled, the port's blade is not fully enabled (faulted, powered off, or disabled), or if the port itself is persistently disabled. Notes The front panel LED of an enabled and online - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 500
F_BSY The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To display error counters for ports on a switch: switch:admin> porterrshow frames enc crc too too bad enc disc link loss loss frjt fbsy tx rx in err shrt long eof out c3 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 501
to Admin Domain restrictions that may be in place. Operands none Examples To display the port status for all ports in the switch: switch:user> portflagsshow Slot Port SNMP Physical Flags 1 0 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT 1 1 Online In_Sync PRESENT - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 502
operands: -npass count Specify the number of times to perform this test. The default value is 10. -ports itemlist Specify a list of user ports to run the test. If omitted, all the active ports in the switch are assumed. For more information, refer to the itemList command. Examples To test - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 503
. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To clear the port log: switch:admin> portlogclear switch:admin> portlogshow port log is empty See Also portLogDump, portLogShow Fabric OS Command Reference 477 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 504
. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To display the current port log configuration: switch:admin> portlogconfigshow max portlog entries = 8192 See Also portLogResize 478 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 505
portlogdisable Description Use this command to disable the port log facility. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands None. Examples To display the port log facility: switch:admin> portlogdisable See Also portLogEnable Fabric OS - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 506
the saved log. This operand is optional. portid Specify the port to display. All other ports will not be displayed. This operand is optional. Examples To display the port log for a port: switch:user> portlogdump 20 time task event port cmd args 08:35:27.899 tShell pstate 14 OL1 08 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 507
in the log without any page breaks. It is identical to portLogShowPort, except that portLogShowPort prompts the user to press Enter between each page. Port logs are circular log files in the switch firmware, which can save up to 8,192 entries. Refer to portLogConfigShow to display the current - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 508
portLogEnable Description Use this command to enable the port log facility. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands None. Examples To enable the port log facility. switch:admin> portlogenable See Also portLogDisable 482 Fabric OS - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 509
14 scn 0 15 pstate 0 16 reject 0 17 busy 0 18 ctin 0 19 ctout 0 20 errlog 0 21 loopscn 0 22 create 0 23 debug 1 24 nbrfsm 0 25 timer 0 26 sn 0 27 fcin 0 28 fcout 0 29 read 0 30 write 0 48 cmd 0 49 event 0 50 msg 0 51 switch 0 52 ficonq - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 510
Flogs and EE (end-to-end) credit for PLOGIs. df_sz The default frame size for this login. cos Class of Services supported. This can be a combination of the following bits: 4 Class 2 is supported. 8 Class 3 is supported. Further information about each login is displayed after these columns - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 511
that may be in place. Operands This command has the following operand: 0|1 Specify 0 to clear or 1 to set the debug_pdisc_flag. Examples To set the debug_pdisc_flag: switch:admin> portlogpdisc 1 PDISC log setting = 1 See Also none Fabric OS Command Reference 485 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 512
. Refer to portLogClear for events that might disable the port log facility. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To enable the port log: switch:admin> portlogreset See Also none 486 Fabric OS Command Reference - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 513
this command to resize the port log to specified number of entries. If num_entries is less than the already configured port log size, no change is is 32,768 to 65,536 for Brocade 48000 Director and Brocade 7500 Switch, and 8,192 to 16,384 for all others. Examples To resize the portlog: switch:admin - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 514
log files in the switch firmware, which can save up to 32,768 entries. Refer to portLogConfigShow to display the current port log size. Once the log is full, the newest log entries delete the oldest log entries. Port logs capture switch-to-device, device-to-switch, switch-to-switch, some device-to - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 515
frame nsRemQ rscn xalloc xfree xerr xstate payload Port Cmd ioctl Tx & Rx scn pstate ctin fc f8 ctout errlog loopscn OLP LIP LIM BMP OLD TMO Args start disable Speed negotiation states Incoming fibre channel information unit Outgoing fibre channel information unit Information unit header log from - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 516
-PH reject reason FC-PH busy reason Argument 0 is divided into two 16-bit fields: [A] a bit map indicating whether subsequent args are valid (0001 means argument 1 is valid, 0003 means arguments 1 and 2 are valid). [B] the CT-based service command code. Argument 1 is the first word of the CT payload - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 517
: OLS Receive State OL3 Offline: Wait for OLS State LIP reason 8001 Retry loop init 8002 Start loop after gaining sync 8003 Restart loop after port reset 8004 LIP when a loop hangs 8005 Restart loop if LIP received when sending out ARB(F0) 8006 LIP when an OPN returns 8007 Restart - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 518
For a full explanation of the information displayed by this command, refer to the Fabric OS Administrator's Guide. The execution port log for a port: switch:user> portlogshow 24 time task event port cmd args 17:05:30.384 PORT Rx 0 40 02fffffd,00fffffd,08fbffff,14000000 17:05:30.384 PORT - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 519
that may be in place. Operands This command has the following operands: portid Specify the port number of the port to display. Examples To display a port log for port 14: switch:user> portlogshowport 14 time task event port cmd args 08:35:28.483 tFabric scn 14 0 08:35:27.899 tShell - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 520
values corresponding to different log types can be obtained by running portLogEventShow. Examples To disable event 2 from reporting to the port log: switch:admin> portlogtypedisable 2 See Also portLogDisable, portLogEventShow, portLogTypeEnable 494 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 521
type to be enabled. The values corresponding to different log types can be obtained by running portLogEventShow. Examples To enable event 2 to report to the port log: switch:admin> portlogtypeenable 2 See Also portLogEventShow, portLogTypeDisable Fabric OS Command Reference 495 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 522
to verify the functional operation of the switch by sending frames from the port N transmitter and looping them back into the same port N receiver. The loopback is done at the parallel loopback path. The path exercised in this test does not include the media or the fiber cable. Only one frame is - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 523
all odd ports' speed for 2 Gbit/sec. -ports itemlist Specify a list of blade ports to test. By default, all of the blade ports in the specified slot (--slot) are used. See itemList for more information. Examples To run a functional test of a connection: switch:admin> portloopbacktest -ports 1/10 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 524
2 portLoopbackTest ERRSTAT INIT PORTDIED STATS TIMEOUT XMIT Refer to the Fabric OS Message Reference for more information. See Also itemList 498 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 525
" or "Enabled" port mirror connection. To display all configured mirror ports on a switch use the portCfgShow command. The port mirroring feature is only supported on the following platforms: Brocade 4100, Brocade 4900, Brocade 7500, and Brocade 48000 Option 5. The mirror port location can impact - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 526
cannot both be 0x000000. Examples To configure a port as a mirror port: switch:admin> portcfg portmirror 2/1 --enable Please confirm enable of Mirror Port: 17 (Y,y,N,n): [n] y To add a port mirror connection between two local switch ports: switch:admin> portmirror --add 2/1 0x011400 0x012400 To - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 527
To display port mirror connections: switch:admin> portmirror --show Number of mirror connection(s) configured: 2 Mirror_Port SID DID State 10/12 0x791800 0x791900 Defined 10/15 0x791a00 0x799300 Enabled See Also portCfgShow portMirror 2 Fabric OS Command Reference 501 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 528
port name. Like all other configurable port attributes, port name persists across reboots and power cycles port number to be configured, relative to its slot for bladed systems. Use switchShow to display a list of valid ports. name Specify a port name. The port name is a character string up to 32 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 529
ports on the switch. Data displays in 8 or 16 columns, one column per port plus one column that displays the total for these ports each sample. Default is one link may not match the output on the device port. Examples To display port throughput for a switch: switch:user> portperfshow 20 0 1 2 3 4 5 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 530
by a slash (/). portnumber Specifies the number of the port to display, relative to its slot for bladed systems. Use switchShow to display a list of valid ports. Examples To display the routing tables for a port: switch:user> portrouteshow 4/15 port address ID: 0x02bf00 504 Fabric OS Command - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 531
portRouteShow 2 external unicast routing table: 1: 0x4 (vc=3) 2: 0x10000 (vc=0) internal unicast routing table: 60: 0x8000 (vc=2) 63: 0x1000 (vc=5) broadcast routing table: 0x10000 See Also bcastShow, fabricShow, switchShow, topologyShow, uRouteShow Fabric OS Command Reference 505 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 532
), the command displays specific FCIP related port configuration parameters, such as the following: • Address resolution protocol (ARP) entries • IP interfaces on the GbE port • Static routes on the IP interfaces • Fibre Channel over IP (FCIP) tunnel configuration settings • Port Mode information - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 533
. portId The port's 24-bit port ID. portIfId The user port's interface ID. portWwn The port's World Wide Name. portWwn of devices(s) connected The World Wide Port Names of connected devices. Distance The port's long-distance level. In case of LD mode, the user configured distance and actual - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 534
ID and WWN of the principal switch. BB XLate Information on the xlate (translate) phantom domain presented at this port. Includes the preferred (if not of the xlate phantom domain. The xlate phantom domain connected at this port is in the same fabric as the router and represents the edge fabric - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 535
its slot for bladed systems. For GigE ports, the ports are numbered ge0 - ge1. See switchShow for a list of valid ports. Use portShow with one of the following options and optional arguments, to display specific FCIP related parameters configured for a gigabit Ethernet port. all | tunnel_id For - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 536
vlantag ftrace Displays emulated FDCBs. Displays active FDCBs. Displays Emulation Control Block (port specific). Displays FICON Host Path Block. Displays FICON Device Path Block. Displays FICON Channel Control Block. Displays FICON Control Unit Control Block. Displays FICON Device Control Block - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 537
0 2_parity_err: 0 CMI_bus_err: 0 Lr_out: 7 Ols_in: 2 Ols_out: 3 Port part of other ADs: No To view xlate domains, you must be running a Brocade 7500 or 48000 with a FC4-18i blade. Note that the Front Domain ID is what is shown: switch:admin> portshow 8/4 portName: portHealth: No Fabric - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 538
.168.255.26 0 Interface, 192.168.255.0 255.255.255.0 192.168.255.27 0 Interface, 172.16.123.231 255.255.0.0 192.168.255.25 1 To display ISCSI Port WWN and Sessions: switch:admin> portshow iscsi 2/ge0 GE Port 2/ge0 Port WWN Sessions 50:06:06:9e:40:09:a2:00 0 To display the connection - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 539
portShow 2 switch:admin> portshow fciptunnel 9/ge0 0 -params Slot: 9 Port: ge0 Tunnel ID 0 Remote IP Addr 10.62.0.100 Local IP Addr 10.10.9.100 Remote WWN Not Configured Local WWN 10:00:00:05:1e:39:d4:5a Compression on Fastwrite on Tape Pipelining on Uncommitted bandwidth, minimum of 1000 Kbps - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 540
switch:admin> portshow fciptunnel 9/ge0 0 -perf Slot: 9 Port: ge0 Tunnel ID 0 Remote IP Addr 10.62.0.100 Local IP Addr 10.10.9.100 Remote WWN Not Configured 29286242 compressed Bytes 2065 Bps 30s avg, 3695 Bps lifetime avg 1.64 compression ratio FC control traffic TCP connection: Local 10.10.9.100: - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 541
To display the connection IPSec information on an FCIP tunnel on a GbE port: switch:admin> portshow fciptunnel 9/ge0 -ipsec Slot: 9 Port: ge0 Tunnel ID 0 Remote IP Addr 10.62.0.100 Local IP Addr 10.10.9.100 Remote WWN Not Configured Local WWN 10:00:00:05:1e:39:d4:5a Compression on Fastwrite - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 542
data: switch:admin> portshow fciptunnel 9/ge0 0 -credits Slot: 9 Port: ge0 Tunnel ID 0 Remote IP Addr 10.62.0.100 Local IP Addr 10.10.9.100 Remote WWN Not Configured Local WWN Credit processing: ip_api_data_credit_target = 32 ip_api_data_credit_ratio = 80 ip_api_credit_time = - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 543
Policy 1 IPSec Policy 1 Pre-Shared Key testingFIPSandIPSec To display QoS Mappings: switch:admin> portshow fciptunnel 9/ge0 0 -qosmap Slot: 9 Port: ge0 Tunnel ID 0 Remote IP Addr 10.62.0.100 Local IP Addr 10.10.9.100 Remote WWN Not Configured Local WWN 10:00:00:05:1e:39:d4:5a Compression - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 544
2 portShow See Also authUtil, portCfg, portCfgLongDistance, portLoginShow, portName, switchShow 518 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 545
portStats64Show 2 portStats64Show Displays the 64-bit hardware statistics for a port. Synopsis portstats64show [slotnumber/]portnumber Description Use this command to display the following hardware statistics for a port. Two integers are reported for most values. In such cases, the top word is - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 546
number to be displayed, relative to its slot for bladed systems. Use switchShow to display a list of valid ports. Examples To display the 64-bit hardware statistics for a port: switch:user> portstats64show 4/15 stat64_wtx 0 top_int : 4-byte words transmitted 316 bottom_int : 4-byte words - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 547
portStats64Show 2 er64_enc_out 0 top_int : Encoding error outside of frames 9131157 bottom_int : Encoding error outside of frames er64_disc_c3 0 top_int : Class 3 frames discarded 0 bottom_int : Class 3 frames discarded stat64_rateTxFrame 17 Tx frame rate (fr/sec) stat64_rateRxFrame 17 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 548
.This command also clears the hardware statistics for the associated three ports in the target port's quad, including ALPA-based CRC monitor, End-to-End monitor, and Filter-based performance monitor statistics. Inter-Switch Link (ISL) monitor statistics are not cleared by this command. For platforms - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 549
port hardware statistics counters. Some counters are platform and port specific and display only with those platforms and ports. All statistics have a maximum 32 to diminishing credit reserves in the transmitter at the other end of the fiber. This is sampled once every 348 106.25 MHz clocks, and the - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 550
platform and port specific). er_inv_arb bladed systems only, specifies the slot number of the port to be displayed, followed by a slash (/). [ge]portnumber Specifies a port number to be configured, relative to its slot for bladed of statistics for a port: switch:admin> portstatsshow 13 stat_wtx - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 551
ip_err_crc ip_err_hdr_cksum ip_err_tcp_data_chksum 0 IP CRC Errors 0 IP Checksum Errors 0 IP TCP Data Checksum Errors To display port statistics for IP address 192.168.255.10, slot 8, and GbE port 1: switch:admin> portstatsshow ip 8/ge1 192.168.255.10 ipaddr 192.168.255.10 IP address Fabric OS - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 552
2 portStatsShow ip_out_octets ip_out_octets ip_out_pkts ip_out_ucast_pkts ip_out_bcast_pkts ip_out_mcast_pkts ip_in_octets ip_in_octets ip_in_pkts ip_in_ucast_pkts ip_in_bcast_pkts ip_in_mcast_pkts ip_err_crc ip_err_hdr_cksum ip_err_tcp_data_chksum See Also portErrShow, portShow 159896 IP - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 553
power cycles. To undo a previous port swap, execute portSwap again on the same two ports. portSwap information is kept in its own database; it cannot be manipulated by editing the configuration slot for bladed systems. Examples To swap area numbers between a pair of ports: switch:admin> portswap - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 554
enabled state of the portswap feature is persistent across reboots and power cycles. Enabling or disabling the portswap feature does not effect previously . Operands none Examples To disable the portswap feature: switch:admin> portswapdisable See Also portSwap, portDisable, portEnable, portShow - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 555
enabled state of the portswap feature is persistent across reboots and power cycles. Enabling or disabling the portswap feature does not effect previously . Operands none Examples To enable the portswap feature: switch:admin> portswapenable See Also portSwap, portDisable, portEnable, portShow - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 556
to display the enabled state of the portswap feature, as well as port and area information for those ports whose area number id different from the default area number. The default area number of a port is same as its switch port number. The execution of this command is subject to Admin Domain - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 557
fiber cable into port M's receiver, thus exercising all the switch components from the main board, to the fiber cable, to the media (of the devices and the switch following operands: -ports itemlist Specify a list of user ports to test. By default, all the user ports in the switch are tested. Refer - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 558
values are predefined for porttype: -1 All ports (default). -2 All L_Ports. -3 All F_Ports. -4 All E_Ports. -5 All N->N loopback ports. Examples To run a functional test on an active switch: switch:admin> porttest -ports 1/1-1/3 See Also portLoopbackTest, portTestShow, spinFab, stopPortTest - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 559
itemlist Specify a list of user ports to test. By default, all the user ports in the current slot will be assumed. Refer to itemList help pages for further details. Examples To display information from portTest: switch:admin> porttestshow 1 Port 1 : PASS PortType: OTHER PortInternalState - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 560
Effective configuration: (No Access)" is displayed. Notes This command requires a Brocade Advanced Zoning license. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To display the zone membership information of ports: switch:user - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 561
done. This is because the lack of power causes the CP boards' processors to cease execution of the firmware. In this situation, all operation of the system terminates immediately: for instance, if two power supplies already have been removed from a Brocade director, and than a third one is removed - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 562
off: (7..10) [7] 10 6th slot to be powered off: (7..9) [8] 9 7th slot to be powered off: (7..8) [8] 8 8th slot to be powered off: (7..7) [7] 7 Old POL New POL Power Off Order 10 1 1st 9 2 2nd 8 3 3rd 7 4 4th 4 10 5th 3 9 6th 2 8 7th 1 7 8th Proceed to change the POL - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 563
Operands none Examples To display the slot power off list order: switch:admin> powerofflistshow Slot 10 will be powered off 1st Slot 9 will be powered off 2nd Slot 8 will be powered off 3rd Slot 7 will be powered off 4th Slot 6 will be powered off 5th Slot 5 will be powered off 6th Slot 4 will be - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 564
is present but predicting failure. faulty Power supply present but faulty (no power cable, power switch turned off, fuse blown, or other internal error). For certain switch models, the OEM serial ID data displays after each power supply status line. The execution of this command is subject - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 565
Reboots the control processor (CP) in a switch or a director. Synopsis reboot -f Description When this command is issued on a switch, if the switch is part of a fabric, all traffic to and from that switch stops. All Fibre Channel ports on that switch including E_Ports become inactive until the - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 566
To display a list of routing-related commands: switch:admin> routehelp aptpolicy bcastshow dlsreset dlsset dlsshow fspfshow database Display FSPF (TM) neighbors' states Reset the FSPF (TM) interface counters Display the unicast fabric topology Configure a static route Remove a static route - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 567
. For switches running earlier versions of Fabric OS (up to v5.3.0), the maximum is 256 Kb. Notes The effective security DB size is the lowest supported by the CP that runs Fabric OS v6.0.0. The Brocade 200E is unable to handle the maximum DB size supported in v6.0.0 and will issue a compact flash - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 568
up secret keys does not initiate DH-CHAP authentication. If switch is configured to do DH-CHAP, it is performed whenever a port or a switch is enabled. Warning: Please use a secure channel for setting secrets. Using an insecure channel is not safe and may compromise secrets. Following inputs should - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 569
secret: Enter local secret: Re-enter local secret: Enter WWN, Domain, or switch name (Leave blank when done): Are you done? (yes, y, no, n): [ to key store... Done. To delete the entire secret key database: switch:admin> secAuthSecret --remove --all This command deletes database of DH-CHAP - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 570
• Delete a CSR. • List the certificates present in the switch. • Display the contents of a certificate/CSR. • Delete a specific certificate. • Configure SSL certificate file name. • Enable secure protocols. Operands The following operands are supported: delcsr Delete CSR delete file name Delete - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 571
all existing certificates. 3. Reset the certificate filename to switch:admin> seccertutil gencsr Country Name (2 letter code, eg, US): State or Province Name (full Password: password Success: imported certificate [certificate file name]. To import a certificate with configure and enable option: switch - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 572
or ".pem" suffix): filename Enter Login Name: login Enter Password: password Success: imported certificate [certificate file name]. Certificate file in configuration has been updated. Secure http has been enabled. To display contents of a CSR: switch:admin> seccertutil showcsr To display contents of - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 573
running Fabric OS v6.0.0 and later, the maximum security database size is 1 Mb. For switches running earlier versions of Fabric OS (up to v5.3.0), the maximum is 256 Kb. The effective security DB size is the lowest supported by the fabric. The presence of a Standby CP that runs an earlier version of - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 574
display security server (secd) specific information as a snapshot of supported between releases and is subject to change without notice. Operands Examples none To view the current security state: switch 215b Zone Size (include enabled configuration) 312 bytes Zone sum e04b215b sec_db: free - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 575
secGlobalShow 2 primaryDLPhase 0 ----wwnDL State----- pid tid key sec usec --------- LOG CACHE --------14:08:50 813905136 secipadm_ipchange receives notification 14:08:50 850588912 secProcessIPChange starts processing 14:08:50 850588912 secProcessIPChange acks completion [Output truncated] - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 576
secpolicysave secpolicyshow secstatsreset secstatsshow Configure FIPS mode operation Creates public an existing policy Saves defined policy set and sends to all switches Shows members of one or more policies Resets security statistics Displays security statistics See Also none 550 Fabric OS - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 577
policy is not set for the particular policy. Notes When FCS Policy is enabled, this command can be issued only from the Primary FCS switch. Only the user who made the changes to the defined database may use this command to abort them. Operands none Examples To abort all changes that have - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 578
is the same for tolerant and strict fabric-wide consistency. When FCS Policy is enabled, this command can be issued only from the Primary FCS switch. Any modifications to SCC, DCC, and FCC DB are saved and activated. When secPolicyActivate is issued after the secPolicySave command, it might fail - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 579
this command can be issued only from the Primary FCS switch. The secpolicyadd command can be issued on all switches for SCC and DCC policies as long as fabric- name has the common prefix DCC_POLICY_ followed by a string of user-defined characters. These characters do not have to be capitalized like - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 580
is a list of devices associated with a specific switch and port combination. An empty DCC_POLICY does not stop access to the switch. The device is specified with a WWN string. The switch and port combination must be in the following format: switch port switch can be specified using WWN, domain, or - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 581
Switch Connection Control (SCC), Device Connection Control (DCC), and Fabric Configuration Server (FCS) policies on the local switch values for DCC_POLICY_nnn are user defined alphanumeric or underscore This will create a unique policy for each port in the fabric locking it down to the device - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 582
is a list of devices associated with a specific switch and port combination. An empty DCC_POLICY does not stop access to the switch. The device is specified with a WWN string. The switch and port combination must be in the following format: switch port switch can be specified using WWN, domain, or - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 583
secPolicyCreate 2 See Also fddCfg, distribute, secPolicyAbort, secPolicyActivate, secPolicyAdd, secPolicyDelete, secPolicyDump, secPolicyRemove, secPolicySave, secStatsShow Fabric OS Command Reference 557 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 584
FCS policy is enabled, this command can be issued only from the Primary FCS switch. Operands This command has the following operands: "name" Specify the name of name has the common prefix DCC_POLICY_ followed by a string of user defined characters. These characters do not have to be capitalized - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 585
name has the common prefix DCC_POLICY_ followed by a string of user defined characters. These characters do not have to be capitalized like :69:30:15:5c 1 primaryfcs 2 No 10:00:00:60:69:30:1e:62 4 switch ACTIVE POLICY SET FCS_POLICY Pos Primary WWN DId swName 1 Yes 10:00:00:60:69:30 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 586
Only one FCS can be moved at a time. The first FCS switch in the list that is also present in the fabric is the Primary FCS. FCS Policy must be enabled on the switch to execute this command. If no parameters are specified, the command becomes interactive, - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 587
followed by a string of user defined characters. These characters do specific switch and port combination. The device is specified with a WWN string. The switch and port combination must be specified in the following format: switch port switch can be specified using WWN, domain, or switch - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 588
to specify the port values: (1-6) Selects ports 1 through 6. (*) Selects all ports on the switch. [3, 9] Selects ports 3 and 9 and all devices attached to those ports. [1-3, 5] Selects ports 1 through 3 and 5 and all devices attached to those ports. [*] Selects all ports on the switch and devices - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 589
saves the modified SCC, DCC, and FCS policies to the Defined Security Policy Set on the local switch. This command is always a local switch operation. A fabric-wide consistency configuration does not affect the behavior of this command. Operands none Example To save defined policy set to - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 590
or Defined security policy set. The command can be issued from all FCS switches. This command displays the policy database one page at a time. Use secPolicyDump name has the common prefix DCC_POLICY_ followed by a string of user defined characters. These characters do not have to be capitalized - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 591
secPolicyShow 2 See Also fddCfg, secPolicyAbort, secPolicyActivate, secPolicyAdd, secPolicyCreate, secPolicyDelete, secPolicyDump, secPolicyRemove, secPolicySave Fabric OS Command Reference 565 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 592
This command can be issued on any switch to reset the security statistics on the local switch or chassis. If FCS policy is enabled and secStatsReset is issued on the primary FCS switch, this command can reset security statistics for any or all switches in the fabric. Operands When invoked without - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 593
policy is enabled and when the command is issued from the primary FCS switch. When domain is specified, the name operand is required. Examples To reset all statistics on the local switch: switch:admin> secstatsreset About to reset all security counters. ARE YOU SURE (yes, y, no, n):[no] y Security - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 594
security statistics. Synopsis secstatsshow [name[, "domain[;domain]"]] Description Use this command to display one or all security statistics. This command can be issued on any switch to display local security statistics. If FCS policy is enabled and secStatsShow is issued on the primary FCS - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 595
are grouped together. Specify a list of domains, for which to display the security statistics. Specify an asterisk (*) in quotation marks to represent all switches in the fabric or specify a list of domains separated by semicolons. This option can only be executed when FCS policy is enabled and the - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 596
sensorshow Description Use this command to display the current temperature, fan, and power supply status and readings from sensors located on the switch. The actual location of the sensors varies, depending on the switch type. The execution of this command is subject to Admin Domain restrictions - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 597
debug messages to the serial console. By default, no debug messages are displayed. High debug level values can generate a large volume of messages, degrading the system response time. The set of supported NS to value 3: switch:admin> setdbg NS 3 switch:admin> dbgshow NS - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 598
of the diagnostic test methods so that ports without media installed are not tested. Diagnostic tests may fail if any port is not operating properly, but with setting. This operand is optional. Examples To enable the media mode: switch:admin> setgbicmode 1 GBIC mode is now 1 (Enabled). See Also - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 599
the diagnostic test methods so that ports without media installed are not tested. Diagnostic tests may fail if any port is not operating properly, but with setting. This operand is optional. Examples To display the media mode: switch:admin> setmediamode -show Media mode is now 0 (disabled). See - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 600
-240 VAC 12A 50-60 Hz 200-240 VAC 12A 50-60 Hz POWER SUPPLY 1 2.015 Modem dial-in must be through a Hayes-compatible modem attached to a CP modem serial port. If the CP is active, the modem is configured to answer an incoming call on the first ring, unless modem dial-in has - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 601
setModem 2 In the recommended configuration, a separate modem is connected to each modem port of CP0 and CP1. These modems that modem dial-in be disabled. Examples To disable modem dial-in to a CP: switch:admin> setmodem -d disabling modem, please wait, this can take a couple of minutes... - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 602
of the diagnostic test methods so that ports without media installed are not tested. Diagnostic tests fail if any port is not operating properly, but with media optional. Examples To enable, disable, and then display the media mode: switch:admin> setsfpmode 0 SFP mode is now 0 (disabled). See Also - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 603
These levels filter the display of the debug message to the serial console. By default, no debug messages are displayed. The execution of this command To set the verbose level of module named NS to value 3: switch:admin> setverbose NS 3 switch:admin> dbgshow NS Module NS, debug level = 0, verbose - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 604
display, relative to its slot for bladed systems. Use switchShow to list valid ports. This operand is optional; if omitted, this command displays a summary of all SFPs in the switch. -all Displays detailed data for all available SFPs on the switch. This operand is not compatible with slotnumber - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 605
BR Max: 0 BR Min: 0 Serial No: H11QET9 Date Code: 020429 Temperature: 50 Centigrade Current: 10634 mAmps Voltage: 3164.8 mVolts RX Power: 199.6 uWatts TX Power: 235.2 uWatts To display detailed information for GbE port 0 on a Brocade 7500: switch:admin> sfpshow ge0 Identifier: 3 SFP - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 606
: 0 (units nm) Options: 001a Loss_of_Sig,Tx_Fault,Tx_Disable BR Max: 0 BR Min: 0 Serial No: A00143427 Date Code: 020511 To display all SFP information: switch:user> sfpshow -all Port 0: Identifier: 3 SFP Connector: 7 LC Transceiver: 050c402000000000 100,200_MB/s M5,M6 sw - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 607
Vendor OUI: 08:00:5a Vendor PN: IBM42P21SNY Vendor Rev: AA10 Wavelength: 0 (units nm) Options: 001a Loss_of_Sig,Tx_Fault,Tx_Disable BR Max: 5 BR Min: 5 Serial No: 21P70530005BW Date Code: 01062301 (output truncated) switchShow sfpShow 2 Fabric OS Command Reference 581 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 608
serial ports. Flow control is disabled by default. Because this command changes the flow control on the console serial port, it must be executed from a session that is logged in from the console serial port. This command cannot run from a telnet session. This setting saves in the configuration switch - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 609
is disabled by default. Because this command changes the flow control on the console serial port, it must be executed from a session that is logged in from the console serial port. This command cannot run from a telnet session. This setting saves in the configuration database; therefore, persistent - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 610
has the following operand: slotnumber Specify the slot number of the blade to be powered down. This operand is required. Examples To power off blade unit 3: switch:admin> slotpoweroff 3 Slot 3 is being powered off See Also powerOffListSet, powerOffListShow, slotPowerOn, slotShow 584 Fabric OS - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 611
This command has the following operand: slotnumber Specify the slot number of the blade to be powered on. This operand is required. Examples To power on blade unit 3: switch:admin> slotpoweron 3 Powering on slot 3. See Also slotPowerOff, slotShow Fabric OS Command Reference 585 53-1000599 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 612
port blade 36 FC4-48 port blade 39 FC10-6 port blade 50 CP8 control processor blade 52 Core8 switch blade 37 FC8-16 port blade 55 FC8-32 port blade 51 FC8-48 port blade Status Displays the status of the blade as one of the following: VACANT The slot is empty. INSERTED, NOT POWERED - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 613
, as% of total and BTU. • Power efficiency: watts/port and watts/Gb. -m In addition to the basic slot status view, displays the Brocade model name for each blade. Examples To display a basic view of all slots and their status: switch:user> slotshow Slot Blade Type ID Status 1 SW - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 614
BTU) Power Efficiency: 9.91 watts per port, 2.48 watts per Gb To display Brocade model names for each blade in the chassis: switch:user> slotshow -m Slot Blade Type ID Model Name Status 1 AP BLADE 33 FA4-18 ENABLED 2 SW BLADE 55 FC8-32 ENABLED 3 SW BLADE 37 FC8-16 ENABLED - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 615
speeds to 3 GBit/sec 4 Sets and locks all port speeds to 4 GBit/sec (default) -ports itemlist Specifies a list of blade ports to test. Specify the slot number followed by a slash (\) on bladed systems. By default, all the blade ports in the specified slot is used. Fabric OS Command Reference - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 616
the number of test repetitions. By default, the test runs once. Refer to itemList for further details. Examples To test the serial link of the following port path: switch:admin> sltest -ports 0/5-0/31 -speed 4 -lb_mode 1 passcnt 1 Running Port sltest .... passed. Diagnostic When it detects - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 617
this command to manage the configuration of the SNMP agent in the switch. The configuration includes SNMPv1 and SNMPv3 configuration, access control list (ACL), MIB capability, system group, and security level settings. The command supports set, reset to default, and display operations. All values - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 618
Two user roles, snmpadmin and snmpuser are supported. snmpadmin provides read-write access and snmpuser provides read-only access. Entries are added to USM table corresponding to each role. Total of three entries for snmpadmin and snmpuser respectively are supported. Separate default passwords are - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 619
user names are: User 1: snmpadmin1 User 2: snmpadmin2 User 3: snmpadmin3 User 4: snmpuser1 User 5: snmpuser2 User 6: snmpuser3 The --default option sets user name and password to default. If FCS policy is enabled, the above configuration has to be updated on both primary and nonprimary switches - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 620
cp Status Changed, and fruHistoryTrap. System Group Configuration Parameters sysDescr The system description. The default value is set as Fibre Channel Switch. sysLocation The location of the system (switch). The default value is set as End User Premise. sysContact The contact information for - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 621
2 Authentication and Privacy. 3 OFF Examples To display the SNMPv1 configuration: switch:admin> snmpConfig --show snmpv1 SNMPv1 community and trap recipient configuration: Community 1: Secret C0de (rw) Trap recipient: 10.32.147.113 Trap recipient Severity Level: 0 Community 2: OrigEquipMfr (rw - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 622
the systemGroup configuration to default values: switch:admin> snmpconfig --default systemGroup ***** This command will reset the agent's system group configuration back to factory default ***** sysDescr = Fibre Channel Switch sysLocation = End User Premise sysContact = Field Support authTraps - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 623
[1] See Also None SW_v5_x.mib, "Switch Management Information & Switch Enterprise Specific Trap" RFC1157, "A Simple Network Management Protocol (SNMPv1)" RFC1213, "Management information Base for Network Management of TCP/IP-based internets: MIB-II" RFC2574, "User-based Security Model (USM) for - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 624
the actual number of frames sent will be slightly larger, particularly at 2 Gbit/sec link speeds. -ports itemlist Specify a list of user ports to test. By default, all of the ISL ports in the current switch will be tested. Refer to itemList help pages for further details. 598 Fabric OS Command - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 625
This mode is disabled by default. Examples To test cascading ISL links: switch:admin> spinfab -ports 1/0 - 1/2 spinfab running... spinfab: Completed 11 megs, status: passed. port 0 test status: 0x00000000 -- passed. port 1 test status: 0x00000000 -- passed. port 2 test status: 0x00000000 -- passed - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 626
2 spinFab See Also itemList, portLoopbackTest 600 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 627
If value is nonzero, then the diagnostics statistics for the blade ports specified in -bports clears; otherwise, the user ports specified in -uports clears. The default value is 0. Examples To clear port and diagnostic statistics: switch:admin> statsclear -bports 1/10-1/62 -use_bports 1 See Also - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 628
to Admin Domain restrictions that may be in place. Operands This command has the following operand: -ports itemlist Specify a list of user ports to test. By default, all the user ports in the switch are tested. Refer to itemList help pages for further details. Examples To stop the portTest - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 629
current configuration. If disabled, the daemon does not capture any data even when a message with FFDC attributes is logged. FFDC is enabled by default. The FFDC configuration: switch:admin> supportffdc --show First Failure Data Capture (FFDC) is disabled. To enable the FFDC events: switch:admin> - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 630
should be less than 48 characters. -u username Specifies FTP user name. username should be less than 48 characters. -p password Specifies FTP user password. If the user name is anonymous, the password is not needed. password should be less than 48 characters. -d remotedirectory Specifies remote - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 631
:admin> supportftp -s Host IP Addr[1080::8:800:200C:417A]: User Name[njoe]: Password[********]: Remote Dir[support]: Auto file transfer parameters changed To display a time interval to check the FTP server: switch:admin> supportftp -t 24 supportftp: ftp check period changed. To enable auto file - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 632
.The FFDC data will be removed after the command. If there are BP blades installed in the switch, it will also retrieve support file (as a.tar.gz file) from each slot. This command accepts IPv4 and IPv6 addresses. If the configured IP address is in IPv6 format, the RAS auto file transfer and event - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 633
-Zone_Log.ss: 27.71 kB kB/s 9.23 Saving support information for switch:swd76, module:Zone_Log... /tmp/supportSave_files/swd76-S6-200508280207-Zone_Log.ss: 48.16 kB kB/s 16.02 Saving support information for switch:routing1, module:RCS_Log... ...portSave_files/routing1-S6-200508280207-RCS_Log - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 634
-S6-200508280208-CHKCONFIG.ss: 1.04 kB 694.31 B/s Saving support information for switch:routing1, module:CONSOLE... ...e_files/routing1-S6-200508280208-CONSOLE: 64 kB 694.31 B/s Saving support information for switch:routing1, module:CHKRPM... ...e_files/routing1-S6-200508280208-CHKRPM.ss: 10 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 635
-Zone_Log.ss: 27.71 kB kB/s 9.23 Saving support information for switch:swd76, module:Zone_Log... /tmp/supportSave_files/swd76-S6-200508280207-Zone_Log.ss: 48.16 kB kB/s 16.02 Saving support information for switch:routing1, module:RCS_Log... ...portSave_files/routing1-S6-200508280207-RCS_Log - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 636
find core files exception (ENABLED by default) errDump pdShow port (ENABLED by default) diagShow (per-slot) portShow (per-port) portLoginShow (per-port) portRouteShow (per-port) portCamShow (per-port) portLogDump (per-port) fabric (ENABLED by default) fabricShow islShow trunkShow 610 Fabric OS - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 637
fabSwitchShow fabPortShow fspfShow nbrStateShow fcpLogShow zone stateshow portZoneShow cfgShow cfgSize rcssmshow rcsInfoShow rcsregistryshow zone mergeshow zone stateshow services (ENABLED by default) fdmiCacheShow fdmiShow nsShow nsAllShow nscamShow nscamShow -t ns portshow security (ENABLED by - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 638
2 supportShow sin df ifconfig route hostname portlog (ENABLED by default) portLogDump system (ENABLED by default) myId version firmwareShow upTime switchStatusShow switchShow haDump (includes haShow and ipAddrShow) tempShow sensorShow psShow licenseShow portFlagsShow portCfgShow portErrShow - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 639
2 extend (DISABLED by default) buffers (per-port) credits (per-port) data (per-port) phantom (per-port) properties (per-port) statistics (per-port) filter (DISABLED by default; this group has lengthy output) filterportshow (per-port) perfmon (DISABLED by default) ps_dump (per-port; this group has - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 640
to display. If the slotnumber/portnumber parameter is omitted, all ports in the switch display in the per-port outputs. The slotnumber must be provided when specifying a range of ports on multi-bladed products. lines Specifies the number of lines of portLogDump output to display. If this parameter - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 641
group commands port Disables the port group commands fabric Disables the fabric group commands services Disables the service group commands security the OS group of commands under the supportShow command: switch:admin> supportshowcfgdisable os Config update Succeeded See Also supportShow - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 642
exception group commands port Enables the port group commands fabric Enables the fabric group commands services Enables the service group commands security a group of commands under the supportShow command: switch:admin> supportshowcfgenable os Config update Succeeded See Also supportShow - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 643
Examples To display which groups of commands are enabled in thesupportShow command: switch:admin> supportshowcfgshow os enabled exception enabled port enabled fabric enabled services enabled security enabled network enabled portlog enabled system enabled extend disabled filter - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 644
switch beaconing mode. When beaconing mode is turned on, the port LEDs flash amber, left to right and right to left, from port 0 to the highest port number and back to port or disabled port for example) is suppressed and only the beaconing pattern is shown. However, if diagnostic frame-based tests ( - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 645
. Synopsis switchcfgpersistentdisable Description Use this command to persistently disable the switch. All Fibre Channel ports are taken offline. If the switch was part of a fabric, the remaining switches reconfigure. The switch remains disabled even after a reboot. The disable process can be - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 646
to persistently enable the switch. All Fibre Channel ports which did not fail power-on self-test (POST) are enabled, and can come online if connected to a device, or remain offline if disconnected. The switch might need to be enabled if it was previously disabled to make configuration changes or to - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 647
The configuration is saved in flash memory and persists across switch reboots or power cycles. If any port on the switch is not capable of the specified speed setting, an error message displays for that port. The output of portShow displays the achieved speed level and portCfgSpeed displays the user - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 648
on all the ports of a switch. This command requires the Brocade ISL Trunking license. You can disable or enable trunking using the portCfgTrunkPort or switchCfgTrunk commands. When the command is executed to update the trunking configuration, the ports for which the configuration applies are - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 649
Description Use this command to disable the switch. All Fibre Channel ports are taken offline; if the switch was part of a fabric, the remaining switches reconfigure. The switch must be disabled before making configuration changes (using configure or configDefault) or before running many of - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 650
Description Use this command to enable the switch. All Fibre Channel ports that passed POST are enabled. They can come online if connected to a device, or will remain offline if disconnected. Use switchEnable if you disable the switch to make configuration changes or to run diagnostics. If the - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 651
is subject to Admin Domain restrictions that may be in place. Operands This command has the following operand: name Specify a new name for the switch. name can include up to 15 characters, must begin with a letter, can consist of letters, digits, hyphens, and underscore characters, and no spaces - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 652
. This command is not supported on single-domain systems. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To reboot an operational switch: switch:admin> switchreboot Stopping all switch daemons...Done. Powering off slot 1...Done - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 653
Area up to 255. Then it will continue to the maximum port of the platform. Index is to identify the port number relative to the switch. Index column is only displayed for slot based platforms. Slot Slot number; 1-4 and 7-10. Port Port number; 0-15, 0-31 or 0-47. Address The 24-bit Address - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 654
Offline Online Proto ISCSI shortwave laser longwave laser copper serial ID The speed of the port: 125 Mbit/sec 250 Mbit/sec 500 Mbit/sec sec fixed transfer speed 4 Gbit/sec negotiated transfer speed Auto negotiating Unknown Port state information: No interface card present. No module (GBIC or other) - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 655
; displays WWN of the attached edge switch. Mirror Port The port is a mirror port. (Trunk master) Port is the master port in a group of trunking ports. (Trunk port, master is port #x) Port is configured as a trunking port; the master port is port #x. (upstream) E_Port is an upstream path toward - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 656
command to display the number of ports on the iSCSI sessions associated with GE ports in a switch. Examples To display the port count: switch:admin> switchshow -portcount ports= 64 To display GE ports with iSCSI sessions: switch:admin> switchshow -iscsi Ports of Slot 1 ge0 ge1 ge2 ge3 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 657
00:04:00:00 95 8 15 035f00 id N2 Online 10:00:00:00:00:02:00:00 208 8 16 03d000 -- -- Offline [output truncated] 216 8 24 03d800 -- -- Online 10:00:00:60:69:e2: F-Port F-Port VE-Port VE-Port VE-Port VE-Port VE-Port VE-Port VE-Port VE-Port To display a switch in Access Gateway mode: switch: - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 658
Blade 0 1 Flash 0 1 MarginalPorts 2 1 FaultyPorts 2 1 MissingSFPs 0 0 Any single contributor can force the overall status of the switch to MARGINAL or DOWN. For example, assuming that the switch contributor values are set to the default values, if there is one faulty port in a switch - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 659
the prompt is (0..0), ** the policy parameter is NOT applicable to the switch. ** Simply hit the Return key. The minimum number of Bad PowerSupplies to MARGINAL status: (0..2) [1] Down Blade contributing to DOWN status: (0..8) [0] Down Blade contributing to MARGINAL status: (0..8) [1] - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 660
Default Contributor, Values, and Status Contributor DOWN Default MARGINAL Default PowerSupplies 2 1 Temperatures 2 1 Fans 2 1 WWN 0 1 CP 0 1 Blade switch. For example, if the FaultyPorts DOWN parameter is set to 3, and three ports fail in the switch, then the status of the switch - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 661
MissingSFPs 0 0 See Also switchStatusPolicySet, switchStatusShow switchStatusPolicyShow 2 Fabric OS Command Reference 635 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 662
the overall status for a switch that is configured with IPv4 and IPv6 addresses. In addition, users with a Fabric Watch license are able to view the list of unhealthy ports. This command displays the overall switch status, and the status of the following contributors: • Power supplies • Temperatures - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 663
is configured with an IPv4 address: switch:user> switchstatusshow Switch Health Report Switch Name: switch IP address: 10.32.89.26 SwitchState: MARGINAL Duration: 80:12 Report time: 09/11/2006 05:39:28 PM Power supplies monitor Temperatures monitor Fans monitor Flash monitor Marginal ports - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 664
. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To view the uptime for the switch: switch:user> switchuptime 9:50pm up for 20 mins See Also switchReboot 638 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 665
DCC. Notes This command can be executed on both active and standby CP. This command does not support HA. Examples To display DCC violations on a switch: switch:admin> switchviolation --dump -dcc Device WWN Port 22:00:00:04:cf:75:59:87 10 See Also None Fabric OS Command Reference 639 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 666
users, depending on the system configuration. The specified facility is used when forwarding messages to the servers added through the command syslogdIpAdd. The default . Examples To set the syslog facility to LOG_LOCAL1: switch:admin> syslogdfacility -l 1 Syslog facility changed to LOG_LOCAL1 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 667
appropriate log files or users, depending on the system configuration. When one or more IP addresses are configured, the switch forwards all error log entries to the syslogd on the specified server(s). Up to six servers are supported. The - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 668
syslog daemon. These can be IPv6 or IPv4 syslogd address configurations. Synopsis syslogdipremove ip_address Description Use this command to remove the IP the list of machines to which system messages are sent: switch:admin> syslogdipremove 1080::8:800:200C:417A See Also errShow, syslogdFacility - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 669
Use this command to display all syslog daemon IP addresses in the configuration database. The execution of this command is subject to Admin Domain Operands none Examples To display all syslog daemon IP addresses: switch:admin> syslogdipshow syslog.IP.address.1 1080::8:800:200C:417A See - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 670
system. For Brocade directors, when sysShutDown is called in the active control processor (CP), the command shuts down the active CP, standby CP, and any AP blades. After doing this, you need to manually power off the system. If you want to reboot the system, manually turn the power switch on. This - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 671
: device is busy The system is halted flushing ide devices: hda Power down. ppc440gx System Halted For the FR4-18i AP blade, to perform a system shutdown from the standby CP: switch:admin> sysshutdown Shut down the whole system is not support from the standby CP For shut down the whole system please - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 672
-in errlogs; the logs by blade are saved in /var/log/verify.slot files. On fixed-port-count products, the slot defaults to 0. The command monitors the run. This allows users to modify the burn-in parameters prior to the run. These diagSetCycle parameters are copied to all switches in the system and - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 673
in the fabric: switch:admin> systemverification -short systemverification: Setting parameters for short run. systemverification: burnin parameters. CURRENT - KEYWORD : DEFAULT 1 - number_of_runs : 1 2 - vib : 2 10 - thermal : 10 SYSTEMVERIFICATION - label : BURNIN 2 - min_lb_mode - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 674
and Fahrenheit. Notes Refer to the hardware reference manual for your switch to determine the normal temperature range. The in place. Operands none Examples To display temperature and status sensors: switch:user> tempshow Index Slot State Centigrade Fahrenheit 1 1 Ok 41 105 2 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 675
login timeouts. This operand is optional; if omitted, the command displays the current timeout value. Examples To set the idle timeout to 10 minutes: switch:admin> timeout 10 IDLE Timeout Changed to 10 minutes The modified IDLE Timeout will be in effect after NEXT login See Also none Fabric OS - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 676
switch. For each path cost, the associated output port on the local switch, the path cost, the number of hops from the local switch to the destination switch and a summary of all ports of the out port. A bandwidth that is less than 0.512 Gbit/sec is adjusted to the nearest power of 2 value, - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 677
2 domains in the fabric; Local Domain ID: 1 Local Translate Domain 4 owned by port: 5 Local Translate Domain 8 owned by port: 4 Domain: 6 Metric: 500 Name: switch Path Count: 4 Hops: Out Port: In Ports: Total Bandwidth: Bandwidth Demand: Flags: 1 60 None 2.000 Gbps 0 % D Hops: Out - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 678
the dump status on the switch. If there is no parameter specified, this command defaults to traceDump -S. The default remote file name format is chassisname dump time. If non-blade system has an embedded BP, two trace dumps will be generated, one with .dmp for the main switch and one with .tar - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 679
Admin Domain restrictions that may be in place. Examples To display information on the track-changes commands: switch:admin> trackchangeshelp trackChangesSet Configure alert for login/logout/config update trackChangesShow Displays status of track changes See Also trackChangesSet, trackChangesShow - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 680
disable the SNMP-TRAP messages. The default (if no operand is specified) is to disable SNMP-TRAP messages. This operand is optional. Examples To enable the track-changes feature: switch:admin> trackchangesset 1, 1 Committing configuration...done. switch:admin> trackchangesshow Track changes status - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 681
output from the track-changes feature is dumped to the error log for the switch. Use the errDump command or errShow command to view the error log. The Examples To display the status of the track-changes feature: switch:admin> trackchangesshow Track changes status: ON Track changes generate SNMP - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 682
one of the following messages, based on the trunking properties of the two specified ports: • Switch does not support trunking • Trunking license required • Trunking not supported in switch interop mode • port port_id is not E_Port • port port_id trunking disabled • port port_id speed is not 2G or - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 683
output for additional information on the port types of the local switch and WWNs of the remote switches. See EXAMPLES, below. deskew The firmware automatically sets the minimum deskew value of the shortest ISL to 15. Master Displays whether this trunking port connection is the master port - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 684
:1e:37:12:13 64-> 16 10:00:00:05:1e:37:12:13 65-> 19 10:00:00:05:1e:37:12:13 4 deskew 17 MASTER 4 deskew 16 4 deskew 16 4 deskew 16 4 deskew 17 4 deskew 17 4 deskew 15 4 deskew 16 switch:admin> switchshow 48 4 0 013000 id N4 Online EX-Port (Trunk port, master is Slot 4 Port 1 ) 49 4 1 013100 id N4 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 685
be specified as operand to set the clock server back to default. The NTP server used must support a full NTP client. Fabric OS v3.1.0 and v2.6.1 have an saved: switch:admin> tsclockserver LOCL switch:admin> tsclockserver "123.123.123.123" Updating Clock Server configuration...done. switch:admin> - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 686
2 tsClockServer See Also date 660 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 687
to leave the time zone setup at the default. Time zone is used only in computing local time, which is used for error reporting and logging. An incorrect time zone setup does not affect the switch operation in any way. System services started during the switch boot reflect time-zone change only at - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 688
which will then default to zero. These switch:admin> tstimezone Time Zone Hour Offset: 0 Time Zone Minute Offset: 0 switch:admin> tstimezone -3, -30 Updating Time Zone configuration Montserrat 48) Virgin Islands (UK) 15) Cuba 32) Netherlands Antilles 49) Virgin Islands (US) 16) Dominica - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 689
- south Idaho & east Oregon 16) Mountain Time - Navajo 17) Mountain 32:45 UTC 2006. Is the above information OK? 1) Yes 2) No Enter number or control-D to quit ?1 System Time Zone change will take effect at next reboot To revert back to the old format: switch admin> tstimezone --old 2 switch - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 690
value is 1. -ports itemlist Specifies a list of blade ports to test. By default, all the blade ports in the specified slot are tested. Refer to the itemList command help page for more information. Examples To execute this test: switch:admin> turboramtest -passcnt 2 -ports 2/0-2/63 Running Turbo - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 691
been running, how many users are currently logged on, and the system load averages for the past 1, 5, and 15 minutes. For up and powered-on times less than the length of time the system has been operational: switch:admin> uptime 12:03am up 4:56, 3 users, load average: 1.17, 1.08, 1.08 See Also - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 692
route configuration is not supported on Brocade directors set to chassis configuration option port 1 and addressed to domain 2 to go through port 5: switch:admin> urouteconfig 1 2 5 done. switch:admin> urouteshow 1/1 2 Local Domain ID: 1 In Port Domain Out Port Metric Hops Flags Next (Dom, Port - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 693
remove a previously configured static route. After this command is issued, the route to domain for in_area might change to use a different output port, only if a static route for all traffic coming in from port 1 and addressed to domain 2: switch:admin> urouteremove 1 2 done. See Also configShow, - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 694
the number of the input port whose routes are to be displayed, relative to its slot for bladed systems. Use switchShow to display a list of valid ports. This operand is optional; if omitted, the command displays routing information for all input ports in the switch. 668 Fabric OS Command Reference - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 695
1 27 1000 1 D 1,1 27 2 16 1500 2 D 4,16 To display the routing information of port 11 to domain 4 only: switch:admin> urouteshow 1/11, 4 Local Domain ID: 3 In Port Domain Out Port Metric Hops Flags Next (Dom, Port) 11 4 16 500 1 D 4,16 See Also portRouteShow, topologyShow - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 696
the man page for these commands for specific information on how the USB device is space. Valid applications are: firmware, support, config, firmwarekey. A specified contents of the attached USB device: switch:admin> usbstorage -l firmwarekey\ 0B support\ 106MB support1034\ 105MB config\ 0B - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 697
15 15:13 Available space on usbstorage 74% To remove an application area: switch:admin> usbstorage -r firmware FW_v6.0.0 To disable an attached USB device: switch:admin> usbstorage -d USB storage disabled supportSave, firmwareDownload, configUpload, configDownload, firmwareKeyupdate Fabric OS - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 698
management functions. Notes The userConfig command operates on the switch-local user database only, regardless of whether the switch is configured to use RADIUS authentication or not. The account database supports a maximum of 256 customer created accounts. 672 Fabric OS Command Reference 53 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 699
user account or modifies an existing user account. The following rules apply: • You cannot change the role, AD permissions or home AD of any default of the account that creates or modifies a user account. The following operands are supported with the --add and --change options: username - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 700
AD permissions of the account that runs the userConfig --delete command. --addad |--deletead Adds AD(s) to a user account or delete AD(s) from a user account. The following operands are supported: username Specifies the account login name. -h AD_ID This operand is optional. • If home AD is - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 701
Date: Not Applicable Locked: No AD membership: 0 Home AD: 0 To change account attributes: switch:admin> userconfig --change joe -e no Broadcast message from root Sat Apr 2 03:03:32 2005... Security Policy, Password or Account Attribute Change: joe will be logged out Attribute for account joe has - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 702
is a default login name, it must indicate the same role as old_username. This command is not supported on all platforms. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands The following operands are required: old_username The current user login - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 703
in the boot PROM Usually the Made on and Flash dates are the same, because the switch starts running flash firmware at power-on. However, in the time period between firmwareDownload and the next reboot, the dates can differ. The execution of this command is subject to Admin - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 704
switch. All switches have a numeric address that is the unique Fibre Channel address used for communicating with the switch. switch components. However, the restart of the switch must happen before any firmwareDownload or (for bladed systems) CP failover occurs; otherwise, the behavior of the switch - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 705
a specific set of source ports. The provision (a.k.a TI Zone) is part of the defined zone configuration and will not appear in the effective zone configuration. A Maximum of 255 TI Zones can be created in one fabric. Notes TI zones are not supported in fabrics involving switches running firmware - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 706
configuration, a zone alias, or several zones. If a source zone object is not specified, the all zone configurations happen on transaction and defined buffer. User can not specify a mode option or zone. mode Specifies the zone database location. Supported mode flag values are: 0 Uses the zone - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 707
, by default, with failover enabled and the zone will be activated. This operand is supported only with ONLINE again, the route will be setup again and the switch will generate another SCN/RSCN. f Enables failover mode. Users will be prompted to confirm the deletion. Fabric OS Command - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 708
configuration. Displays command usage. Examples 1. Specific Zone Operation commands: The following example shows a scenario of an invalid configuration Domain. To copy cur_cfg1 zone configuration from the root zone database (AD0) to the current Admin Domain: switch:admin> zone --copy AD0.cur_cfg1 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 709
-f You are about to prune the zone configurations, based on zone --validate output. Do you want to prune the zone configurations (yes, y, no, n): [no] y 2. Traffic Isolation Zone Commands: To create a Traffic Isolation Zone with failover enabled (default). switch:admin>zone --create -t ti red_zone - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 710
8,3; 8,5; Failover: Disabled Status: Deactivated To display the status of "blue_zone" in the defined configuration: switch:admin>zone --show blue_zone Zone Name: blue_zone: List of port: 1,2; 1,3; 3,3; 4,5 Failover: Enabled Status: Activated See Also ad, zoneHelp 684 Fabric OS Command Reference - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 711
to become effective, an appropriate zone configuration must be enabled using the cfgEnable command. Notes This command requires a Brocade Advanced Zoning license. When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands The following operands are required - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 712
. Zone names are limited to 64 characters. The zone member list port name), at the port in the fabric to which it is connected. This command changes the defined configuration. For the change to be preserved across switch switch controls data transfer to a port. Notes This command requires a Brocade - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 713
other zone object. Zone names are limited to 64 characters. "member" List of members to be included in zone, in quotation marks, separated by semicolons. Quotation marks are required. Can be one or more of the following: A switch domain and port area number pair: for example, "2, 20". View the - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 714
to become effective, an appropriate zone configuration must be enabled using the cfgEnable command. Notes This command requires a Brocade Advanced Zoning license. When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands This command has the following - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 715
help information: switch:admin> zonehelp configuration to the defined configuration Print zone configuration information Print size details of zone database Abort zone configuration transaction Print zone configurations in transaction buffer Activates or deactivates a default zone configuration - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 716
For the change to become effective, an appropriate zone configuration must be enabled using the cfgEnable command. Notes Refer to the zoneCreate command for more information on name and member specifications. This command requires a Brocade Advanced Zoning license. When FCS policy is enabled, this - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 717
to become effective, an appropriate zone configuration must be enabled using the cfgEnable command. Notes This command requires a Brocade Advanced Zoning license. When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands This command has the following - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 718
For the change to become effective, an appropriate zone configuration must be enabled using the cfgEnable command. Notes Refer to the zoneCreate command for more information on name and member specifications. This command requires a Brocade Advanced Zoning license. When FCS policy is enabled, this - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 719
to become effective, an appropriate zone configuration must be enabled using the cfgEnable command. Notes This command requires a Brocade Advanced Zoning license. When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands This command has the following - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 720
FCS switch in the fabric. Operands This command has the following operands: "pattern" A POSIX-style regular expression used to match zone configuration names The default value is 0. This operand is optional. Examples To display all zones beginning with the letters "A" through "C": switch:admin - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 721
secure FOS are fully integrated into the base FOS. This chapter summarizes the commands that switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Can be run on all FCS switches. Must be run from the primary FCS switch - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 722
Description Must be run from the primary FCS switch. Must be run from the primary FCS switch. Can be run on all switches. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. msTdDisable "ALL" must be run from the primary - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 723
when logged in to the standby CP on a Brocade 48000 or DCX Data Center Backbone director. The full set of commands for your user role are available to the active CP. Commands Supported on the Standby CP The following commands are supported when logged into the standby CP. TABLE 22 Commands - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 724
Saves support information for RASLOG, TRACE, and supportShow. switchName Displays this switch's name . switchViolation Display policy violations recorded in RAS log tsClockServer Displays time zone. upTime Displays how long switch has been up. version Displays firmware - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 725
the local switch is part of the current AD. View access allowed if the device attached to the port is part of current AD. • AD0Disallowed = Allowed to execute only in AD255 and AD0 (if no ADs are configured). • AD0Only = Allowed to execute only in AD0 when ADs are not configured. 4. Command-specific - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 726
and Admin Domain availability of all Fabric OS commands. TABLE 1 RBAC Availability and Admin Domain Type Command Name User Admin Operator Switch Admin aaaConfig ad ag agShow aliAdd aliCreate aliDelete aliRemove aliShow aptPolicy auditCfg authUtil bannerSet bannerShow bcastInfoShow bcastShow - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 727
TABLE 1 RBAC Availability and Admin Domain Type Command Name User Admin Operator Switch Admin cfgDisable O cfgEnable O cfgMcdtMode 0 cfgRemove O N configList N configRemove N configShow N configUpload N configure N dataTypeShow O date O dbgShow O defZone O - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 728
A Command RBAC Permissions and AD Types TABLE 1 RBAC Availability and Admin Domain Type Command Name User Admin Operator Switch Admin diagSetBurnin diagSetCycle diagShow diagSkipTest diagStatus diagStopBurnin distribute dlsReset dlsSet dlsShow dnsConfig enclosureShow errClear errDelimiterSet - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 729
RBAC Permissions and AD Types A TABLE 1 RBAC Availability and Admin Domain Type Command Name User Admin Operator Switch Admin fazoneAdd fazoneCreate fazoneDelete fazoneRemove fazoneShow fcipChipTest fcipHelp fcipPathTest fclUnQuery fcPing fcpLogClear fcpLogDisable fcpLogEnable fcpLogShow - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 730
Permissions and AD Types TABLE 1 RBAC Availability and Admin Domain Type Command Name User Admin Operator Switch Admin ficonCupSet O ficonCupShow O ficonHelp O ficonShow O fipsCfg N firmwareCommit O firmwareDownload O firmwareDownloadStatus O firmwareKeyShow O firmwareRestore - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 731
Command RBAC Permissions and AD Types A TABLE 1 RBAC Availability and Admin Domain Type Command Name User Admin Operator Switch Admin haFailover haReboot haShow haSyncStart haSyncStop help historyLastShow historyMode historyShow httpcfgShow i ifModeSet ifModeShow interfaceShow interOpMode O - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 732
TABLE 1 RBAC Availability and Admin Domain Type Command Name User Admin Operator Switch Admin licensePort O OM OM OM licenseRemove O OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM N OM N Basic Switch Admin OM O O O OM OM O O O O O O O O O O O O O O O OM O O O O O - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 733
Availability and Admin Domain Type Command Name User Admin Operator Switch Admin pathInfo O pdShow O perfAddEEMonitor O OM OM OM OM OM OM OM O OM OM OM OM OM OM O O O OM OM OM OM OM OM OM OM OM Basic Switch Admin O O O O O O O O O O O O O O O O O O O O O O O O O O OM O OM OM OM OM OM - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 734
RBAC Availability and Admin Domain Type Command Name User Admin Operator Switch Admin portCfgGport O portCfgISLMode O portCfgLongDistance O OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM Basic Switch Admin OM OM OM OM OM OM OM OM OM OM OM OM OM O OM OM OM OM O O O - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 735
and Admin Domain Type Command Name User Admin Operator Switch Admin portLogTypeEnable portLoopbackTest portMirror portName OM OM OM OM OM OM OM OM OM O OM N O OM OM OM OM OM OM OM OM OM OM Basic Switch Admin O O N OM O O OM O O O OM OM OM OM O O OM O O O O O O N O O O OM O O O O O O O - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 736
RBAC Permissions and AD Types TABLE 1 RBAC Availability and Admin Domain Type Command Name User Admin Operator Switch Admin secPolicyRemove secPolicySave secPolicyShow O OM N O O OM N O O OM N O secStatsReset O secStatsShow O sensorShow O setDbg O setModem O setVerbose - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 737
Command RBAC Permissions and AD Types A TABLE 1 RBAC Availability and Admin Domain Type Command Name User Admin Operator Switch Admin switchEnable switchName O OM OM OM O OM OM OM switchReboot O switchShow O switchStatusPolicySet O switchStatusPolicyShow O switchStatusShow O - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 738
A Command RBAC Permissions and AD Types TABLE 1 RBAC Availability and Admin Domain Type Command Name User Admin Operator Switch Admin userConfig (for other N OM N N options) userConfig (for the --help OM OM OM OM and --show options) userRename N OM N N version O OM OM OM - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 739
522 Bloom-based platform, 333, 386, 450, 497, 627 Brocade 200E switch, 405, 589, 629 Brocade 24000 director, 69, 629 Brocade 3250 switch, 447 Brocade 3850 switch, 447 Brocade 3900 switch, 447 Brocade 4100 switch, 144, 145, 405, 589, 629 Brocade 48000 director, 405, 589, 629 Brocade 4900 switch, 144 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 740
supported on the standby CP, 697 Condor-based platform, 333, 386, 450, 497, 627 configDefault, 74 configure, 87 Control Processor, 699 and RBAC, 699 CSR certificates, 545 deleting certificates, 545 D default load sharing DMA test, 170 domain name service, 120 dual CP system active CP and supportFTP - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 741
Channel Extended Link Service, 161, 491, 531 Fibre Channel Protocol, 167, 168 FICON, 94, 198, 199, 200, 201, 202, 204, 207, 452, 593, 594, 613, 615, 616, 617, 629 FICON-MIB, 593, 594 FICON-TRAP, 594 field replaceable unit, see FRU filter-based monitor, 387, 393, 395, 396, 397, 401 firmware download - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 742
309, 354, 358, 361 ISL Inter-Switch Link, 399 ISL Trunking, 463, , 68 Advanced Zoning, 30, 31, 32, 33, 52, 53, 54, 55 logical SAN, 325 login, 323 long distance settings, , 87, 88 memory usage, 330 MIB, 68, 69, 74, 91, password and login, 323 and SNMPv3, 593 and supportFTP, 604 and supportSave, 606 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 743
, 686 port type, 203, 204, 205, 207, 418, 475, 531, 533 portAlpaShow, 417 portCamShow, 420 portCfgEXPort, 439, 465 portLogShow, 491 portswap feature, 528, 529, 530 POST, 46, 50, 100, 101, 106, 107, 108, 111, 147, 587, 620, 624 disabling, 100 power-on self-test, see POST primary FCS, 30, 31, 32, 33 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 744
, 504, 505, 668 uRouteConfig, 666 user accounts, 69, 369, 672 user port, 311, 418, 476, 507 V VC_RDY, 445 VEX_Port, 464, 465, 466 virtual channel settings, 88, 89 W WAN_TOV, 76, 87, 88 Web Tools, 267, 399, 625 Z zone, 679 zone alias, 31 adding, 30 zone configuration and cfgActvShow, 52 and zone, 679 - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 745
, 694 zoning Advanced Zoning commands, xxiv and aliCreate, 31 and cfgSize, 65 and configDefault, 74 and configDownload, 76 and lsanZoneShow, 325 cfgSave, 61 clearing zoning configurations, 54 creating, 55 disabling, 57 display in fabStatShow, 141 displayed in fcPing, 161 enabling zone - HP StorageWorks 4/8 | Brocade OS Command Reference Manual Supporting Fabric OS v - Page 746
720 Fabric OS Command Reference 53-1000599-01
53-1000599-01
19 Oct 2007
Fabric OS
Command Reference Manual