HP StorageWorks 8/20q HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev
HP StorageWorks 8/20q - Fibre Channel Switch Manual
View all HP StorageWorks 8/20q manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks 8/20q manual content summary:
- HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 1
HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Event Message Reference Guide Part Number: 5697-0264 Published February 2010 Edition: 1 - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 2
statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Event Message Reference Guide - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 3
guide 5 Intended audience 5 Related documentation 5 Document conventions and symbols 6 HP technical support 6 Product warranties 6 Subscription service 6 HP 7 Informative event messages and descriptions 49 HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Event Message Reference Guide 3 - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 4
4 - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 5
Installation Instructions • HP StorageWorks 8Gb Simple SAN Connection Kit Cabling Guide • HP StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide • HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide • HP StorageWorks SN6000 Fibre Channel Switch - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 6
, calls may be recorded or monitored. Product warranties For information about HP StorageWorks product warranties, see the warranty information website: http://www.hp.com/go/storagewarranty Subscription service HP strongly recommends that customers sign up online using the Subscriber's choice web - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 7
com/support/ • http://www.docs.hp.com Documentation feedback HP welcomes your feedback. To make comments and suggestions about product documentation, please send a message to [email protected]. All submissions become the property of HP. HP StorageWorks 8/20q and SN6000 Fibre Channel Switch - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 8
8 - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 9
the HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide. For more information about the Simple SAN Connection Manager event browser, see the HP StorageWorks Simple SAN Connection Manager User Guide. HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Event Message - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 10
Oct 24 12:30:29.965 UTC 2007][I][8400.0022][Switch][Successful login user (snmp@IB-session6) with admin privilege] For more information about the CLI commands, see the HP StorageWorks SN6000 Fibre Channel Switch Command Line Interface Guide. Configuring the event log You can customize what types of - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 11
errors • Decode errors • Inter-switch link (ISL) connections • Device logins • Device logouts • Loss-of-signal errors For more information, see the HP StorageWorks SN6000 Fibre Channel Switch Command Line Interface Guide. HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Event Message Reference - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 12
12 - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 13
the switch given by domain_ID. (A1003.000E) (Couldn't acquire lock from domain domain_ID) The fabric may be changing, Wait for the fabric to and therefore could not stabilize, then try again. acquire the lock. HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Event Message Reference Guide - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 14
(A1003.0016) (Releasing Lock held too long by domain_ID) A zone merge could not be completed in the acceptable time. Check the status of the switch given by domain_ID. (A1003.0017) (Activation of zoneset by management server failed due to port port_number out of range.) A zone member defined by - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 15
set.) There was a problem handling the activate direct switch indicates that the active zone sets could not be merged. Edit or delete the conflicting zone objects or deactivate the zone set on the remote switch. HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Event Message Reference Guide - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 16
remove the conflict, or deactivate one of the zone sets. (A1003.002F) (SW2 Zoning Not Supported by other switch, Isolating link) The Fabric inter-switch link (ISL) isolated because the local switch is configured for FC-SW-2-compliant zoning (interoperability mode set to Standard), but the remote - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 17
in zone sets exceeds the zoning database limit. Remove zones from either the local switch or the remote switch, so that the combined sum is less than zones in zone sets limit. number. Correct the member type. HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Event Message Reference Guide 17 - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 18
set from the zoning database. (A1003.004C) (Active ZoneSet containing Fibre Channel Address may cause fabric to segment due to switches that do not support this zone member type) Some switches in the fabric may not support Fibre Channel (FC) address zone members in the active zone set. Edit the - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 19
member type not supported) The remote switch's zoning configuration contains a zone member type that is not supported. Edit the switch given by domain_ID. Check the status of the switch at the given domain ID. HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Event Message Reference Guide - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 20
match. (A1003.0069) (Failing remote zoning configuration, invalid zone data received) Zoning activation failed because the switch detected invalid zoning data that is not supported in the local interop mode. Check your zoning configuration and remove incompatible zone members. (A1004.0001) (Port - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 21
time out value configured (R_A_TOV/E_D_TOV).) An E_Port isolated because the values for R_A_TOV or E_D_TOV are not the same on both switches. Modify the switches so that the time out values are the same. HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Event Message Reference Guide 21 - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 22
same throughout the fabric. (A1004.0034) (Failed to connect to a switch due to incompatibility contact technical support.) The two switches are incompatible. Possible causes include incompatible configurations, incompatible firmware versions, and incompatible licensing. Verify that configurations - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 23
.) The domain ID of the switch is changed due to an interoperability configuration change. The old domain ID does not conform to the range of allowed domain IDs for the new interoperability setting. None HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Event Message Reference Guide 23 - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 24
the remote switch failed to respond. Investigate the remote switch for connection problems. ( service entry will be set up to discard these frames. Investigate the source at the specified Fibre Channel (FC) address. (A1004.0054) (Eport Isolating due to Link to self) Two ports on the same switch - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 25
) from address FC_address failed authorization/authentic ation) Security authentication failed. Check the security configuration on both the device and the switch to ensure that they are configured properly. HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Event Message Reference Guide 25 - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 26
that licenses were updated on the switch while running older firmware. Check your license configuration for changes. (A1005.004E) (Attempts to login backend switch fail because backend switch does not support NPIV.) The backend fabric switch does not support N_Port ID Virtualization (NPIV), which - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 27
reset. be activated without disrupting I/O traffic. (A1005.006F) (Hotreset Vversion -> Vversion is not supported) The installed firmware cannot Perform a hard reset. be activated without disrupting I/O traffic. HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Event Message Reference Guide 27 - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 28
Hotreset to older firmware version not supported. A reset is required to activate this version of firmware) The installed firmware cannot Perform a switch) Conditions exist that could damage the switch and the switch was unable to turn off the Fibre Channel (FC) port lasers. Power down the switch - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 29
was detected by the switch firmware that affected a transparent switch attached to the TR_Port from the local fabric or disconnect the TR_Port (transparent routing is not needed to reach devices in the local fabric). HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Event Message Reference Guide - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 30
attempt. The port will isolate. Checks the security configuration on the remote switch to determine the problem. (A1007.0006) (Security: Could not validate Authentication Response from port_number, remote side of the link. Check the transceiver and cable. Update firmware on remote switch. 30 - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 31
challenge authentication frame was received from a remote switch, but the local switch does not have an entry for itself within the active security set ISL group. Edit the ISL group to include the local switch. HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Event Message Reference Guide 31 - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 32
configuration of the management application using the remote port is compatible with the configuration of the Management Server security group on the switch. (A1007.001C) (Security: Bad Authentication Flags) The received AUTH frame did not meet the standard format for the frame payload. Within the - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 33
a Remote Authentication Dial In User Service (RADIUS) configuration problem. Confirm that the shared secret configured on the switch is identical to the shared comparing secrets. Check security configuration. HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Event Message Reference Guide 33 - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 34
0027) (Radius server could not validate authentication response from port_number) A Remote Authentication Dial In User Service (RADIUS) authentication failed. Confirm that the secret is the same on the switch as it is on the RADIUS server. (A1007.0028) (Security: 2-Way Authentication, No security - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 35
A Remote Authentication Dial In User Service (RADIUS) server was configured switch binding list such that the device(s) on the port were no longer allowed to be logged in. Add the devices to the switch binding list. HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Event Message Reference Guide - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 36
) An attempt was made to authenticate a switch login through a Remote Authentication Dial In User Service (RADIUS) server, but no shared secret fan operation, and ambient temperature. If the problem cannot be corrected, power down the switch. (A3001.0001) (Temp overwarm, sensor_name sensor - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 37
switch. Contact technical support if a non-disruptive code load and activation is required. (A6001.0003) (cmon: switch failed NDCLA) The Non-Disruptive Code Load and Activation (NDCLA) has failed. The switch has performed a hard reset. None HP StorageWorks 8/20q and SN6000 Fibre Channel Switch - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 38
.0019) (ZoneSet zone_set has been deactivated by user user_name) A zone set in the zoning database has been deactivated. (C) (8300.001A) (A ZoneSet activation has failed.) An attempt to activate a zone set has failed. (C) (8400.0002) (Switch) (The switch The switch is being reset. is being reset - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 39
(Switch) (The switch is being shutdown - this may take several seconds) The switch is being shutdown. (C) (8400.0027) (Switch) (Invalid user account_name attempted to log into switch) Invalid user login attempt. HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Event Message Reference Guide - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 40
, if you have other vendor's switches in your fabric, please refer to their switch manual/documentation to see what zone member limits the switch supports) You have a large database on the switch consisting of over 3,000 zone members. This could cause a problem in mixed fabrics because not all - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 41
(8400.0065) (Switch) (The switch is being automatically hardreset after leaving the Diagnostics AdminState.) The switch automatically undergoes a hard reset after leaving the Diagnostics administrative state. HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Event Message Reference Guide 41 - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 42
licensing. (C) (8400.008E) (Inconsistent configuration defaults detected. Defaults will be updated.) Two fabrics have been 8600.0013) (PortApp) (Invalid vendor data from media device for port port_number) The switch could not read and verify the media module ID. This may indicate a discovery - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 43
switch cannot be connected to the fabric due to a license restriction. (C) (8700.0013) (Connection failure, fabric limited to two switches) The switch cannot be connected to the fabric due to license restriction. HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Event Message Reference Guide - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 44
of the named profile failed because the Simple Mail Transfer Protocol (SMTP) server IP addresses are the factory defaults or the servers are disabled in the Call Home service configuration. (C) (8B00.0007) (Unable to test profile profile because the FromEmailAddress has not been configured in the - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 45
field will show the reason for the switch status. (C) (8F00:000E) Link Status status The severity level of the link status has changed. The description field will show the reason for the link status. HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Event Message Reference Guide 45 - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 46
do so due to a resource problem. (W) (8400.0007) (Switch) (Attempted unauthenticated login username account_name) A login was attempted with an account name that was not in the list of allowable users of switch management. (W) (8400.0018) (Switch) (User account_name login rejected maximum logins - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 47
address has been configured and enabled) Either both Simple Mail Transfer Protocol (SMTP) server IP addresses in the Call Home service configuration are the default value (0.0.0.0) or they have not been enabled. HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Event Message Reference Guide 47 - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 48
(SMTP) server because of a non-transient error. The Call Home service will not attempt to resend the message. (W) (8F00.000C) (Fabric (8F00.000D) (Switch Status status) The severity of the switch status has changed. The description field will show the reason for the switch status. (W) (8F00 - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 49
Interface (FDMI) information with this switch. An HBA has attempted to register its FDMI information with the switch, but allowing it to do so would cause the FDMI database to exceed the configured limit. HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Event Message Reference Guide 49 - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 50
account_name without admin privilege) (I) (8400.0025) (Switch) (Successful login user account_name without admin privilege) (I) (8400.0026) (Switch) (A zoning configuration edit session has been canceled) (I) (8400.002B) (Switch) (User login account_name is being closed - In-Band connections have - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 51
8600.0020) (SYNC_LOSS) Description A user login session has ended because of switch issues a failure alarm is being changed. A Common Information Model (CIM) edit session has been cancelled. The Call Home service HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Event Message Reference Guide 51 - HP StorageWorks 8/20q | HP StorageWorks 8/20q and SN6000 Fibre Channel Switch ev - Page 52
has discovered a new Fabric inter-switch link (ISL) in the fabric A link has been removed from the display. This is either because the fabric discovery process has discovered that the link is no longer in the fabric, or because the user has deleted the link manually. The login to the fabric has
HP StorageWorks 8/20q and SN6000 Fibre
Channel Switch Event Message Reference Guide
Part Number: 5697-0264
Published February 2010
Edition: 1