- HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 1
HP StorageWorks 8/20q Fibre Channel Switch command line interface guide Part number: 5697-7760 Third edition: January 2009 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 2
is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 3
Contents About this guide 11 Intended audience 11 Related documentation 11 Document conventions and symbols 12 HP technical support 13 Product warranties 13 Subscription service 13 HP web sites 13 Documentation feedback 13 1 Command line interface usage 15 Logging in to the switch through - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 4
43 Zoning configuration parameters 43 Security configuration parameters 44 Hardware information 45 Firmware information 45 Managing switch services 46 Managing switch configurations 48 Displaying a list of switch configurations 48 Activating a switch configuration 48 Copying a switch - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 5
an alias 86 7 Connection security configuration 87 Managing SSL and SSH services 87 Displaying SSL and SSH services 88 Creating an SSL security certificate 89 8 Device security configuration 91 95 Modifying the security database 96 8/20q Fibre Channel Switch command line interface guide 5 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 6
109 11Call Home configuration 111 Call Home concepts 111 Call Home requirements 111 Call Home messages 112 Technical support interface 113 Configuring the Call Home service 114 Managing the Call Home database 115 Displaying Call Home database information 116 Creating a profile 118 Deleting - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 7
threshold 208 set config zoning 210 set log 211 set pagebreak 214 set port 215 set setup callhome 216 set setup radius 218 set setup services 221 set setup snmp 224 8/20q Fibre Channel Switch command line interface - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 8
pagebreak 262 show perf 263 show port 265 show postlog 269 show setup callhome 270 show setup mfg 271 show setup radius 272 show setup services 273 show setup snmp 274 show setup system 275 show steering 277 show switch 278 show system 280 show temp 281 show testlog 282 show - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 9
Policy configuration parameters 174 16 Profile configuration parameters 181 17 Call Home service configuration defaults 188 18 Switch configuration defaults 189 19 Port configuration defaults Port administrative state parameters 215 8/20q Fibre Channel Switch command line interface guide 9 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 10
configuration attributes 216 48 Common RADIUS server configuration attributes 218 49 Server-specific RADIUS server configuration attributes 218 50 Switch services settings 221 51 Common SNMP configuration parameters 224 52 SNMP trap configuration parameters 225 53 DNS host name configuration - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 11
and servicing Fibre Channel equipment using the command line interface. Related documentation The following manuals and materials are referenced in the text and/or provide additional information. • HP StorageWorks 8/20q Fibre Channel Switch installation and reference guide • HP StorageWorks - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 12
blue text: Figure 1 Medium blue, underlined text (http://www.hp.com) Bold font Italics font Monospace font Monospace, italic font Monospace to equipment or data. IMPORTANT: Provides clarifying information or specific instructions. NOTE: Provides additional information. TIP: Provides helpful hints - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 13
• Operating system type and revision level • Detailed, specific questions Product warranties For information about HP StorageWorks product warranties, see the warranty information website: http://www.hp.com/go/storagewarranty Subscription service HP strongly recommends that customers sign up online - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 14
14 About this guide - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 15
• Entering commands, page 16 • Getting help, page 17 • Setting page breaks, page 17 • Creating a support file, page 17 • Downloading and uploading files, page 19 NOTE: Throughout this document, references in the text : 8/20q FC Switch #> exit 8/20q Fibre Channel Switch command line interface guide 15 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 16
parity 2. Enter an account name and password when prompted. The default account name is admin, and its password is password. NOTE: A switch supports a combined maximum of 19 logins or sessions, which are reserved as follows: • 4 logins or sessions for internal applications, such as management server - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 17
support file If you contact technical support about a problem with your switch, they may request that you create and send a support file. This support the problem. The create support command creates the support file download the support file from the switch to your workstation. NOTE: Support files - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 18
bytes in 1 transfers. 221 Thank you for using the FTP service on localhost.localdomain. If your workstation does not have an FTP server, enter the create support command to create the support file, and then use FTP to download the support file from the switch to your workstation, as shown in the - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 19
Backup configuration file (configdata) • Log files (logfile) • Support files (dump_support.tgz) You can upload firmware image files or secs. ftp>quit For more information about reinstallation, backup and restore, and creating support and log files: • See "Installing firmware" on page 54. • See - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 20
20 Command line interface usage - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 21
Maintenance menu to perform switch recovery tasks. For information about using Maintenance mode, see the HP StorageWorks 8/20q Fibre Channel Switch installation and reference guide. This section describes the following user account configuration tasks: • Displaying user account information, page 21 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 22
Creating user accounts A user account consists of an account name, an authority level, and an expiration date, which have the following requirements: • The account name can be up to 15 characters: the first character must be alphanumeric; the remaining characters must be American Standard Code for - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 23
command. account OLD password : ******** account NEW password (8-20 chars) : ******** please confirm account NEW password: ******** password has been changed. 8/20q Fibre Channel Switch command line interface guide 23 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 24
24 User account configuration - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 25
following: • IP configurations (versions 4 and 6) • DNS server configuration To display specific information, add the corresponding keyword. For example, to display IPv6 configuration information, enter False Static 2001::1/64 fe80::1 8/20q Fibre Channel Switch command line interface guide 25 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 26
the following parameters in one session, or you can configure specific parameters by adding the corresponding keyword: • IPv4 configuration, page address that resides on the switch or from a server. The switch supports network discovery from the following server types: • Bootstrap Protocol (BootP) - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 27
IPv6 configuration The switch supports IPv6, which includes the following: • Network discovery method • IP address • IP gateway address The network discovery method Address) : Do you want to save and activate this system setup? (y/n): [n] 8/20q Fibre Channel Switch command line interface guide 27 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 28
DNS server configuration A DNS server manages the host names for a fabric. This enables you to specify servers and switches by a meaningful name rather than IP address. To configure a DNS server, enter the set setup system dns command in an Admin session, as shown in the following example: 8/20q FC - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 29
associations. You can recognize these dynamic policies and associations because their names begin with DynamicSP_ and DynamicSA_ respectively. 8/20q Fibre Channel Switch command line interface guide 29 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 30
switch in maintenance mode, and correct the problem through the serial port interface. For information HP StorageWorks 8/20q Fibre Channel Switch installation and reference guide. Policy and association information To display general or specific policy and association information, enter the ipsec list - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 31
, page 32 • Modifying a user-defined policy, page 33 • Renaming a user-defined policy, page 34 • Copying a policy, page 34 8/20q Fibre Channel Switch command line interface guide 31 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 32
Creating a policy To create a policy, enter the ipsec policy create command as shown in the following example: 8/20q FC Switch #> admin start 8/20q FC Switch (admin) #> ipsec edit 8/20q FC Switch (admin-ipsec) #> ipsec policy create h2h-sh-sp A list of attributes with formatting will follow. Enter - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 33
' command. 8/20q FC Switch (admin-ipsec) #> ipsec save The IPsec configuration will be saved and activated. Please confirm (y/n): [n] y 8/20q Fibre Channel Switch command line interface guide 33 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 34
Renaming a user-defined policy To rename a policy (policy_1), enter the ipsec policy rename command, as shown in the following example: 8/20q FC Switch #> admin start 8/20q FC Switch (admin) #> ipsec edit 8/20q FC Switch (admin-ipsec) #> ipsec policy rename policy_1 policy_4 The security policy will - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 35
confirm (y/n): [n] y 8/20q FC Switch (admin-ipsec) #> ipsec save The IPsec configuration will be saved and activated. Please confirm (y/n): [n] y 8/20q Fibre Channel Switch command line interface guide 35 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 36
Modifying a user-defined association To modify an existing user-defined association, enter the ipsec association edit command in an Admin session and an Ipsec Edit session as shown in the following example. An asterisk (*) indicates a required entry. 8/20q FC Switch (admin-ipsec) #> ipsec - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 37
The IPsec configuration will be reset and the default values activated. Please confirm (y/n): [n] y Reset and activation in progress .... 8/20q Fibre Channel Switch command line interface guide 37 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 38
38 Network configuration - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 39
Switch configuration consists of the following tasks: • Displaying switch information, page 39 • Managing switch services, page 46 • Managing switch configurations, page 48 • Paging a switch, page 51 • 45 • Firmware information, page 45 8/20q Fibre Channel Switch command line interface guide 39 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 40
Name server information The show ns all command displays the list of worldwide names (WWNs) in the fabric, as shown in the following example. The show ns command displays the WWNs that are local to the switch. 8/20q FC Switch #> show ns all Seq Domain Port Port No ID ID Type COS PortWWN - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 41
) Vx.x.x.0 (day month date time year) default Online False Off Online False 00000000 Passed 00000000 NeverRun 32 Normal 8/20q Fibre Channel Switch command line interface guide 41 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 42
System process information The ps command displays system process information to help you determine what processes are running and central processing unit (CPU) usage. The column titles in the following example are: • PID-Process identifier • PPID-Parent process identifier • %CPU-Percentage CPU - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 43
. 8/20q FC Switch #> show config zoning Configuration Name: default Zoning Configuration Information MergeAutoSave True DefaultZone Allow DiscardInactive False 8/20q Fibre Channel Switch command line interface guide 43 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 44
Security configuration parameters To display security configuration and port binding parameters, enter the show config security command. These parameters determine how security is applied to the switch. See Table 35 for descriptions of the switch security configuration parameters. See Table 36 for - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 45
error as described in Table 4. For information about Heartbeat LED blink patterns, see the HP StorageWorks 8/20q Fibre Channel Switch installation and reference guide. Table 4 Heartbeat LED activity HeartBeatCode-HeartBeatStatus Description 1-Normal 2-AppDied 3-PostFailed One blink per second - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 46
commands. To display the status of the switch services, use the show setup services command. See Table 50 for descriptions of the switch services settings. IMPORTANT: Simple SAN Connection Manager version 1.0 does not support the SSL service. If SSL is enabled, you will be unable to manage the - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 47
FC Switch (admin) #> set setup services A list of attributes with formatting and current may be required after enabling a service. * If services are disabled, the connection to the want to save and activate this services setup? (y/n): [n] 8/20q Fibre Channel Switch command line interface - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 48
Managing switch configurations The switch configuration determines the basic operational characteristics of the switch. A switch can store up to 10 configurations, including the default configuration (Default Config). The current switch operating characteristics are determined by the active - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 49
) (string, max=64 chars) [Online ] [True ] [True ] [True ] [1000 ] [2 ] [False ] [8/20q FC Switch] [10000 ] [2000 ] [254 ] [Default Config] 8/20q Fibre Channel Switch command line interface guide 49 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 50
sets, zones, and aliases. • The security database, except the group primary and secondary secrets. • The Call Home database and Call Home service configuration. NOTE: Configuration backup files are deleted from the switch during a power-cycle or a switch reset. Downloading the configuration file Use - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 51
command, as shown in the following example: 8/20q FC Switch #> date Mon Apr 07 07:51:24 2008 8/20q Fibre Channel Switch command line interface guide 51 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 52
Setting the date and time explicitly To set the switch date and time explicitly, use the set timezone and date commands. 1. To change the time zone (to America/North Dakota, for example), enter the set timezone command in an Admin session, as shown in the following example: 8/20q FC Switch #> - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 53
X X X Disrupts I/O traffic X X Reconnects Simple SAN X X X Connection Manager and QuickTools sessions afterwards Clears the event log X X X Deletes supports files, firmware image files that have not been unpacked, and configuration backup files X X Closes all management sessions - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 54
periodically either on CD-ROM or from the HP web site. Installing firmware on a switch However, Telnet sessions must be restarted manually. TIP: After upgrading firmware that includes the upgrade may indicate that the new firmware is not supported. To correct this, close the QuickTools session and - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 55
logged in. The firmware will now be downloaded from the remote host to the switch, installed, and activated. 8/20q Fibre Channel Switch command line interface guide 55 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 56
Custom firmware installation A custom firmware installation downloads the firmware image file from a remote host to the switch, unpacks the image file, and resets the switch in separate steps. This allows you to choose the type of switch reset and whether the activation will be disruptive (reset - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 57
exercises all internal ports, transceivers, and inter-port connections. A transceiver with a loopback plug is required for all ports. 8/20q Fibre Channel Switch command line interface guide 57 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 58
The following example performs an internal connectivity test on a switch: 8/20q FC Switch #> admin start 8/20q FC Switch (admin) #> set switch state diagnostics 8/20q FC Switch (admin) #> test switch connectivity internal A list of attributes with formatting and current values will follow. Enter a - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 59
cc:2e 20:04:00:c0:dd:02:cc:2e Port ---14 4 The HP StorageWorks 8/20q 4-port Upgrade License enables additional Fibre Channel (FC) ports in four number and license key, follow the step-by-step instructions on the firmware feature entitlement request certificate for the line interface guide 59 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 60
Managing idle session timers You can limit the duration of idle login sessions and idle Admin sessions (admin start command). You can specify limits up to 1,440 minutes; specifying 0 means unlimited duration. Idle login sessions that exceed the timeout limit are logged off (InactivityTimeout). An - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 61
MSEnabled NoClose IOStreamGuard PDISCPingEnabled Online Auto GL Port3 False True False False 0 0 True True True False Auto True 8/20q Fibre Channel Switch command line interface guide 61 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 62
Port operational information To display port operational information, enter the show port command. 8/20q FC Switch #> show port 1 Port Number: 1 ------------ AdminState Online AsicNumber 0 AsicPort 2 ConfigType GL DownstreamISL False EpConnState Connected EpIsoReason NotApplicable - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 63
True RisingTrigger 5 FallingTrigger 1 SampleWindow 10 LogoutMonitoringEnabled True RisingTrigger 5 FallingTrigger 1 SampleWindow 10 LOSMonitoringEnabled True RisingTrigger 100 FallingTrigger 5 SampleWindow 10 8/20q Fibre Channel Switch command line interface guide 63 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 64
Port performance To display port performance in terms of the volume of data transmitted, data received, or errors, enter the show perf command. You can display continuous live performance information for one or more ports, or an instantaneous summary. The following example displays an instantaneous - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 65
the next port or switch reset, or until you activate a configuration. IMPORTANT: 8 Gb/s SFPs do not support the 1 Gb/s setting. Setting a Fibre Channel port that has an 8-Gb/s SFP transceiver to 1-Gb/s 8/20q FC Switch (admin)#> admin end 8/20q Fibre Channel Switch command line interface guide 65 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 66
supported in a remote fabric, see the HP StorageWorks 8/20q Fibre Channel Switch release notes, and the HP StorageWorks SAN Design reference guide located at the HP website: http://www.hp to different remote fabrics. • For mappings between a specific 8/20q Fibre Channel Switch and a remote fabric, - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 67
configuration process. See the HP StorageWorks 8/20q Fibre Channel Switch QuickTools switch management user guide. To configure transparent routing remote fabric. For remote HP StorageWorks B-Series fabrics, the switch to which the TR_Port is connected must support NPIV, and the interoperability - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 68
activate zoneset_alpha 5. Apply the same inter-fabric zone that was created on the local fabric to the active zoning on the remote HP StorageWorks B-series fabric. When modifications to the active zoning on both fabrics are complete, the transparent routing connection becomes active, and local - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 69
alarm is cleared when the threshold monitoring detects that the error rate has fallen below the falling trigger. 8/20q Fibre Channel Switch command line interface guide 69 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 70
To enable and configure port threshold monitoring on the switch, enter the set config threshold command: 8/20q FC Switch #> admin start 8/20q FC Switch (admin) #> config edit 8/20q FC Switch (admin-config) #> set config threshold A list of attributes with formatting and current values will follow. - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 71
(s) will appear on the screen when the test has completed. 8/20q FC Switch (admin) #> Test for port 1 Passed. 8/20q Fibre Channel Switch command line interface guide 71 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 72
Offline tests for ports An offline test is a disruptive test that exercises the port connections. You must place the port in the diagnostics state using the set port command before starting the test. There are two types of offline test: internal loopback and external loopback. • An internal loopback - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 73
77 • Alias and alias membership information, page 78 • Zoning modification history, page 78 • Zoning database limits, page 79 8/20q Fibre Channel Switch command line interface guide 73 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 74
Configured zone set information The zoneset list and the zoning list commands display information about all zone sets in the non-volatile zoning database. To display a list of the zone sets, enter the zoneset list command, as shown in the following example: 8/20q FC Switch #> zoneset list Current - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 75
Switch #> zoneset active Active ZoneSet Information ActiveZoneSet Bets LastActivatedBy admin@OB-session6 LastActivatedOn day month date time year 8/20q Fibre Channel Switch command line interface guide 75 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 76
Merged zone set information A merged zone set is a zone set that is received from another switch as a result of a change to the active zone set. You can display the merged zone set on your switch if the MergeAutoSave parameter is set to False. For more information about the MergeAutoSave parameter, - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 77
, as shown in the following example: 8/20q FC Switch #> zone orphans Current list of orphan zones zone3 zone4 8/20q Fibre Channel Switch command line interface guide 77 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 78
Alias and alias membership information The alias list and alias members commands display information about aliases. To display a list of all aliases, enter the alias list command, as shown in the following example: 8/20q FC Switch #> alias list Current list of Zone Aliases alias1 alias2 To display - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 79
active zone set. • DiscardInactive-Enables or disables the discarding of all zone sets except the active zone set. 8/20q Fibre Channel Switch command line interface guide 79 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 80
If MergeAutoSave is False on a switch, and a new zone set is activated elsewhere in the fabric or a fabric merge occurs, you can choose how to dispose of the merged zone set: • To display the merged zone set, enter the zoning merged command. • To edit the merged zone set, enter the zoning edit - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 81
command will overwrite the configured zoning database in NVRAM. Please confirm (y/n): [n] y The merged zoning database has been saved. 8/20q Fibre Channel Switch command line interface guide 81 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 82
Resetting the zoning database There are two ways to remove all aliases, zones, and zone sets from the zoning database: • Enter the reset zoning command, as shown in the following example. This is the preferred method. 8/20q FC Switch #> admin start 8/20q FC Switch (admin) #> reset zoning The zoning - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 83
zoneset_new 8/20q FC Switch (admin-zoning) #>zoning save Copying a zone set To copy a zone set and its contents to a new zone set, enter the zoneset copy command, as shown in the following example: 8/20q FC Switch and a Zoning Edit session. 8/20q Fibre Channel Switch command line interface guide 83 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 84
) #> zoning edit 8/20q FC Switch (admin-zoning) #> zone rename zone_1 zone_a 8/20q FC Switch (admin-zoning) #> zoning save Copying a zone To copy the contents of an existing zone (zone_1) to a new zone (zone_2), enter the zone copy command, as shown in the following example: 8/20q FC Switch #> admin - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 85
alias_a 8/20q FC Switch (admin-zoning) #> zoning save Copying an alias To copy alias_1 and its contents to alias_2, enter the alias copy command, as shown in the following example: 8/20q FC Switch #> (admin-zoning) #> zoning save 1,4 1,5 8/20q Fibre Channel Switch command line interface guide 85 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 86
Removing members from an alias To remove ports/devices from alias_1, enter the alias remove command, as shown in the following example: 8/20q FC Switch #> admin start 8/20q FC Switch (admin) #> zoning edit 8/20q FC Switch (admin-zoning) #> alias remove alias_1 1,4 1,5 8/20q FC Switch (admin-zoning) - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 87
Initiative-Specification (SMI-S) Managing SSL and SSH services Consider the following when enabling SSH and SSL services: • Simple SAN Connection Manager version 1.0 does not support the SSL service. If a security certificate on the switch. 8/20q Fibre Channel Switch command line interface guide 87 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 88
the end of the list press 'q' or 'Q' and the ENTER key to do so. PLEASE NOTE Further configuration may be required after enabling a service. * If services are disabled, the connection to the switch may be lost. * When enabling SSL, please verify that the date/time settings on this switch and - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 89
and the workstation date and time are the same. See "Managing the date and time" on page 51. 8/20q Fibre Channel Switch command line interface guide 89 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 90
90 Connection security configuration - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 91
command, as shown in the following example: 8/20q FC Switch #> securityset list Current list of SecuritySets alpha beta 8/20q Fibre Channel Switch command line interface guide 91 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 92
To display all security sets, groups, and group members in the security database, enter the security list command, as shown in the following example: 8/20q FC Switch #> security list Active Security Information SecuritySet Group GroupMember No active securityset defined. Configured Security - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 93
:72:45 10:00:00:c0:dd:00:90:ef 10:00:00:c0:dd:00:b8:b7 8/20q Fibre Channel Switch command line interface guide 93 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 94
Security database modification history To display a record of security database modifications, enter the security history command, as shown in the following example: 8/20q FC Switch #> security history Active Database Information SecuritySetLastActivated/DeactivatedBy Remote - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 95
a security set or the merging of fabrics. To replace the volatile security database with the contents of the non-volatile security database, enter the security restore command. To restore the security 8/20q FC Switch (admin)#> admin end 8/20q Fibre Channel Switch command line interface guide 95 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 96
Modifying the security database To modify the security database: 1. Open an Admin session with the admin start command. 8/20q FC Switch #> admin start An Admin session prevents other accounts from making changes at the same time either through Telnet, QuickTools, or Simple SAN Connection Manager. 2. - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 97
) #> securityset rename securityset_old securityset_new Copying a security set To copy a security set and its contents to a new security set, enter the securityset copy command, as shown in the following example and a Security Edit session. 8/20q Fibre Channel Switch command line interface guide 97 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 98
rename command, as shown in the following example: 8/20q FC Switch (admin-security) #> group rename group_port port_1 Copying a group To copy the contents of an existing group (group_port) to a new group (port_1), enter the group copy command, as shown in the following example: 8/20q FC Switch - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 99
following example: 8/20q FC Switch (admin-security) #> group remove group_1 10:00:00:c0:dd:00:90:a3 8/20q Fibre Channel Switch command line interface guide 99 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 100
100 Device security configuration - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 101
's security database, or remotely using a Remote Dial-In User Service (RADIUS) server such as Microsoft RADIUS. With a RADIUS server or both the switch and the initiator device, if the device supports authentication. A RADIUS server can also be configured to authenticate user line interface guide 101 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 102
all RADIUS server configurations. The second group is server-specific. You can configure both groups of parameters for all RADIUS servers, User Authentication SSL can be enabled using the 'set setup services' command. Current Values: DeviceAuthOrder UserAuthOrder TotalServers Local Local 1 New - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 103
to configure RADIUS User Authentication SSL can be enabled using the 'set setup services' command. Server 1 Current Values: ServerIPAddress 10.20.11.8 ServerUDPPort 1812 you want to save and activate this radius setup? (y/n): [n] 8/20q Fibre Channel Switch command line interface guide 103 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 104
104 RADIUS server configuration - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 105
in response to events that occur in the fabric. For a complete listing of switch event messages, see the HP StorageWorks 8/20q Fibre Channel Switch event messages reference guide. Events are classified by the following severity levels: • Alarm-The alarm level describes events that are disruptive to - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 106
Displaying the event log To display the event log, enter the show log command. Each log message has the following format: [ordinal][time_stamp][severity][message_ID][source][message_text] Table 6 describes the message format components. Table 6 Event log message format Component Description [ - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 107
server events • Port events • Switch management events • Simple Network Management Protocol (SNMP) events • Zoning events • Call Home events 8/20q Fibre Channel Switch command line interface guide 107 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 108
host The switch comes from the factory with local logging enabled, which instructs the switch firmware to maintain an event log in switch memory. The can also be configured to log events to a remote host that supports the syslog protocol. This, however, requires that you enable remote logging - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 109
ip_address user:images password: images ftp>bin ftp>get logfile xxxxx bytes sent in xx secs. ftp>quit 8/20q Fibre Channel Switch command line interface guide 109 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 110
110 Event log configuration - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 111
service. The Call Home service configuration consists of primary and secondary Simple Mail Transfer Protocol (SMTP) server specifications each switch that is to support Call Home e-mail notification has its own Ethernet connection. To test your Call Home service and database configurations, enter - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 112
Call Home messages The Call Home service generates e-mail messages for the specified event severity level and the following switch actions: • Switch comes online • Switch goes offline • Reboot • Power up • Power down • - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 113
send switch status and trend data periodically by e-mail to specified technical support resources. To use this feature, you must create a profile named Tech_Support_Center. The capture command enables you to add instructions to the Tech_Support_Center profile to specify the frequency with which to - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 114
set setup callhome command in an Admin session, as shown in the following example. See Table 47 for a description of the Call Home service configuration entries. 8/20q FC Switch (admin) #> set setup callhome A list of attributes with formatting and current values will follow. Enter a new value or - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 115
To display the Call Home service configuration, enter the show setup callhome command, as shown in the following enter the admin end command. To remove all Call Home profiles and restore the Call Home service configuration to its factory state, enter the reset callhome command. 8/20q FC Switch (admin - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 116
Managing the Call Home database consists of the following tasks: • Displaying Call Home database information, page 116 • Creating a profile, page 118 • Deleting a profile, page 118 • Modifying a profile, page 119 • Renaming a profile, page 119 • Copying a profile, page 119 • Adding a data capture - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 117
shown in the following example: 8/20q FC Switch #> callhome queue stats Callhome Queue Information FileSystemSpaceInUse 534 (bytes) EntriesInQueue 3 8/20q Fibre Channel Switch command line interface guide 117 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 118
,None) : Format (1=FullText, 2=ShortText, 3=Tsc1) : MaxSize (decimal value, 650-2000000) : EmailSubject (string, max=64 chars, N=None) : Technical problem RecipientEmail (ex: [email protected], N=None) 1. : [email protected] The profile has been created. This configuration - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 119
the ENTER key to do so. Current Values: Level Alarm Format ShortText MaxSize 1000 EmailSubject Switch Problem RecipientEmail (up to 10 entries allowed) 1. [email protected] New Value (press ENTER Please confirm (y/n): [n] y 8/20q Fibre Channel Switch command line interface guide 119 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 120
Adding a data capture configuration To add a data capture configuration to the Tech_Support_Center profile, enter the capture add command, as shown in the following example. If the Tech_Support_Center profile does not exist, you must create it using the profile create command. 8/20q FC Switch #> - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 121
Passed. Changing Simple Mail Transfer Protocol servers The Call Home service configuration enables you to specify a primary and a secondary SMTP queue will be cleared. Please confirm (y/n): [n] y To display the contents of the Call Home message queue, see "Displaying Call Home database information - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 122
all Callhome profiles, enter the callhome clear command, as shown in the following example. This command does not affect the Call Home service configuration. 8/20q FC Switch #> admin start 8/20q FC Switch (admin) #> callhome edit 8/20q FC Switch (admin-callhome) #> callhome clear 8/20q FC Switch - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 123
service supports SNMP version 3 in the CLI, which is disabled by default. Managing the SNMP service You control the SNMP service SNMPEnabled parameters through the set setup snmp or set setup services services service. * If services save and activate this services setup? (y/n): [n] You can display the - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 124
Displaying SNMP information To display common and trap-specific SNMP configuration information, enter the show setup snmp command, as shown in the Location N_107 System Test Lab Description HP StorageWorks 8/20q FC Switch ObjectID 1.3.6.1.4.1.3873.1.11 AuthFailureTrap - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 125
of parameters for all SNMP traps, or you can configure the common and trap-specific parameters separately. See Table 51 for descriptions of the common SNMP parameters. The following you want to save and activate this snmp setup? (y/n): [n] 8/20q Fibre Channel Switch command line interface guide 125 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 126
The following example configures SNMP trap 1: 8/20q FC Switch (admin) #> set setup snmp trap 1 A list of attributes with formatting and current values will follow. Enter a new value or simply press the ENTER key to accept the current value. If you wish to terminate this process before reaching the - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 127
Authentication-ensures that the packet is coming from a valid source • Encryption-ensures that packet contents cannot be read by an unauthorized source To configure SNMP version 3, you must enable SNMP version 3 user account, page 129 8/20q Fibre Channel Switch command line interface guide 127 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 128
Creating an SNMP version 3 user account To create an SNMP version 3 user account, enter the snmpv3user add command as shown in the following example: 8/20q FC Switch #> admin start 8/20q FC Switch (admin) #> snmpv3user add A list of SNMPV3 user attributes with formatting and default values as - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 129
(True/False) [True ] : f Do you want to save and activate this setup ? (y/n): [n] y SNMPV3 user account edited and activated. 8/20q Fibre Channel Switch command line interface guide 129 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 130
130 Simple Network Management Protocol configuration - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 131
its effects on other commands. The Examples paragraph presents sample screen captures of the command and its output. 8/20q Fibre Channel Switch command line interface guide 131 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 132
admin Description Opens and closes an Admin session. The Admin session provides access to commands that change the fabric and switch configurations. Only one Admin session can be open on the switch at any time. An inactive Admin session will time out after a specified period of time, which is - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 133
be no longer than 64 characters. Valid characters are 0-9, A-Z, a-z, _, $, ^, and -. The zoning database supports a maximum of 256 aliases. delete [alias] Deletes the specified alias given by [alias] from the zoning given by [alias_new]. 8/20q Fibre Channel Switch command line interface guide 133 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 134
Examples The following is an example of the alias list command: 8/20q FC Switch #> alias list Current list of Zone Aliases alias1 alias2 The following is an example of the alias members command: 8/20q FC Switch #> alias members alias1 Current list of members for Zone Alias: alias1 50:06:04:82:bf: - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 135
Fibre Channel Switch Call Home service provides an e-mail notification capability for the switch. This service has no relationship with the HP Call Home feature, which notifies HP services. Authority Admin session, except the profile names. 8/20q Fibre Channel Switch command line interface guide 135 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 136
queue [option] Clears the Call Home e-mail queue or displays Call Home e-mail queue statistics depending on the value of [option]. The Call Home queue statistics parameters are described in Table 7 Table 7 Call Home queue statistics parameters Parameter clear stats Description Clears the Call - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 137
#> callhome queue stats Callhome Queue Information FileSystemSpaceInUse 534 (bytes) EntriesInQueue 3 See also profile, page 181 reset, page 186 8/20q Fibre Channel Switch command line interface guide 137 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 138
starting a Callhome Edit session, see the callhome command. Syntax capture add edit remove Operands add Adds data capture instructions to the Tech_Support_Center profile. Table 8 describes the data capture parameters. Table 8 Data capture configuration parameters Parameter TimeOfDay DayOfWeek - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 139
'callhome save' command before it can take effect, or to discard this configuration use the 'callhome cancel' command. 8/20q Fibre Channel Switch command line interface guide 139 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 140
The following is an example of the capture remove command: 8/20q FC Switch #> admin start 8/20q FC Switch (admin) #> callhome edit 8/20q FC Switch (admin-callhome) #> capture remove Capture Entries for Profile: Tech_Support_Center Index TimeOfDay DayOfWeek Interval 1 02:00 Sat 1 (weeks) - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 141
8/20q FC Switch (admin)#> admin end See also set config port, page 201 show config port, page 241 8/20q Fibre Channel Switch command line interface guide 141 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 142
copy [config_source] [config_destination] Copies the configuration given by [config_source] to the configuration given by [config_destination]. The switch supports up to 10 configurations including the default configuration. delete [config_name] Deletes the configuration given by [config_name] from - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 143
maintenance mode, see the HP StorageWorks 8/20q Fibre Channel Switch installation and reference guide. • Configuration archive files up to 31 characters excluding #, semicolon (;), and comma (,). The switch supports up to 10 configurations, including the default configuration. Notes Changes you make - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 144
The following is an example of how to upload a configuration backup file (configdata) from the workstation to the switch and then restore the configuration. #> ftp symbolic_name or ip_address user: images password: images ftp> bin ftp> put configdata ftp> quit 8/20q FC Switch #> admin start 8/20q - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 145
use FTP to download the support file from the switch to your workstation. The support file is useful to technical support personnel for troubleshooting switch problems. Use this command when directed [n] y Certificate generation successful. 8/20q Fibre Channel Switch command line interface guide 145 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 146
for johndoe. Password: xxxxxxx 230 User johndoe logged in. cd bin/support 250 CWD command successful. lcd /itasca/conf/images Local directory now / in 1 transfers. 221 Thank you for using the FTP service on localhost.localdomain. See also date, page 147 set setup system, page 227 set - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 147
Switch (admin) #> date Thu Jan 31 10:15:03 UTC 2008 See also set setup system, page 227 8/20q Fibre Channel Switch command line interface guide 147 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 148
exit Description Closes the switch connection. Authority None Syntax exit Notes You can also press Control-D to close the switch connection. 148 Command reference - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 149
28 bytes from local switch to 0x970400 time = 119 usec See also fctrace, page 150 ping, page 180 8/20q Fibre Channel Switch command line interface guide 149 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 150
fctrace Description Displays the path from an initiator device port in the fabric to a target device port in the same zone. To trace the path between two initiator ports, you must disable the I/O StreamGuard feature. Use the set config port command to change the IOStreamGuard parameter. Path - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 151
license_key] is case insensitive. log Displays a list of installed license key features. Notes The HP StorageWorks 8/20q 4-port Upgrade License enables additional Fibre Channel ports in 4-port increments up to for 20 ports 1-LCVXOWUNOJBE6 8/20q Fibre Channel Switch command line interface guide 151 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 152
firmware install Description Downloads firmware from a remote host to the switch, installs the firmware, then resets the switch to activate the firmware. This is disruptive. The command prompts you for the following: • The file transfer protocol (FTP or TFTP) • IP address or DNS host name of the - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 153
take several seconds... The switch will now reset. Connection closed by foreign host. See also image, page 164 8/20q Fibre Channel Switch command line interface guide 153 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 154
use to decipher the encrypted primary secret sent by the ISL member. The hash functions are MD5 or SHA-1. If the ISL member does not support the primary hash, the switch will use the secondary hash. Hexadecimal string that is encrypted by the primary hash for authentication with the ISL group - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 155
group member. The hash functions are MD5 or SHA-1. If the Port group member does not support the primary hash, the switch will use the secondary hash. PrimarySecret Hexadecimal string that is encrypted group members. The default is False. 8/20q Fibre Channel Switch command line interface guide 155 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 156
64 characters. Valid characters are alphanumeric, _, $, ^, and -. The security database supports a maximum of 16 groups. If you omit [type], ISL is used. Table 12 . The hash functions are MD5 or SHA-1. If the member does not support the primary hash, the switch will use the secondary hash. The hash - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 157
because of an authentication failure. For more information about managing groups in security sets, see the securityset command. 8/20q Fibre Channel Switch command line interface guide 157 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 158
Examples The following is an example of the group add command: 8/20q FC Switch #> admin start 8/20q FC Switch (admin) #> security edit 8/20q FC Switch (admin-security) #> group add Group_1 A list of attributes with formatting and default values will follow Enter a new value or simply press the - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 159
:c0:dd:00:90:ef 10:00:00:c0:dd:00:b8:b7 See also security, page 194 8/20q Fibre Channel Switch command line interface guide 159 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 160
hardreset Description Resets the switch and performs a power-on self test (POST). This reset disrupts I/O traffic, activates the pending firmware, and clears the alarm log. To save the alarm log before resetting, see the set log command. Authority Admin session Syntax hardreset Notes To reset the - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 161
given, the currently active configuration is edited. Admin mode is required for this command. Usage: config edit [CONFIG_NAME] 8/20q Fibre Channel Switch command line interface guide 161 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 162
history Description Displays a numbered list of the previously entered commands from which you can re-execute selected commands. Authority None Syntax history Notes Use the history command to provide context for the ! command: • Enter ![command_string] to re-execute the most recent command that - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 163
. Verify that the current firmware version supports the installation and non-disruptive activation of , Telnet sessions must be restarted manually. This command clears the event log upgrade may indicate that the new firmware is not supported. To correct this, close the QuickTools session and - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 164
image Description Manages and installs switch firmware. Authority Admin session Syntax image cleanup fetch [account_name] [ip_address] [file_source] [file_destination] install list tftp [ip_address] [file_source] [file_destination] unpack [file] Operands cleanup Removes all firmware image files from - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 165
FC Switch (admin) $>image unpack 8.0.00.11_epc Image unpack command result: Passed See also firmware install, page 152 8/20q Fibre Channel Switch command line interface guide 165 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 166
ipsec Description Manages the IP Security database. The IP Security database consists of the Security Association database and the Security Policy database. The ipsec edit command opens a session in which to create and manage associations and policies. Authority Admin session except for the history - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 167
See also ipsec association, page 168 ipsec list, page 171 ipsec policy, page 174 Maximum ------- 512 128 Current ------- 0 0 8/20q Fibre Channel Switch command line interface guide 167 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 168
name must begin with a letter and be no longer than 32 characters. Valid characters are alphanumeric, _, $, ^, and -. The Security Association database supports a maximum of 512 user-defined associations. You must enter the Ipsec Save command afterwards to save your changes. Table 14 describes the - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 169
[association_new]. You must enter the ipsec save command afterwards to save your changes. Dynamic associations cannot be renamed. 8/20q Fibre Channel Switch command line interface guide 169 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 170
Examples The following is an example of the ipsec association create command: 8/20q FC Switch #> admin start 8/20q FC Switch (admin) #> ipsec edit 8/20q FC Switch (admin-ipsec) #> ipsec association create h2h-sh-sa A list of attributes with formatting will follow. Enter a value or simply press the - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 171
all user-defined policies. edited Displays the configuration for all policies that have been modified, but not saved. 8/20q Fibre Channel Switch command line interface guide 171 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 172
Examples The following is an example of the ipsec list command: 8/20q FC Switch #> ipsec list Active IPsec Information Security Association Database h2h-sh-sa h2h-hs-sa Security Policy Database h2h-hs-sp h2h-sh-sp Summary ------- Security Association Count: 2 Security Policy Count: 2 The - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 173
Mode Level 1 esp transport require See also ipsec, page 166 ipsec association, page 168 ipsec policy, page 174 8/20q Fibre Channel Switch command line interface guide 173 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 174
A policy name must begin with a letter and be no longer than 32 characters. Valid characters are alphanumeric, _, $, ^, and -. The Security Policy database supports a maximum of 128 user-defined policies. You must enter the ipsec save command afterwards to save your changes. Table 15 describes the - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 175
all user-defined policies. edited Displays the configuration for all policies that have been modified, but not saved. 8/20q Fibre Channel Switch command line interface guide 175 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 176
rename [policy_old] [policy_new] Renames the policy given by [policy_old] to the policy given by [policy_new]. You must enter the ipsec save command afterwards to save your changes. Dynamic policies cannot be renamed. Examples The following is an example of the ipsec policy create command: 8/20q FC - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 177
numbered beginning with 0. Examples The following is an example of the lip command: 8/20q FC Switch (admin) #> lip 2 8/20q Fibre Channel Switch command line interface guide 177 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 178
logout Description Closes the switch connection. Authority None Syntax logout Notes You can also press Control-D to close the switch connection. See also exit, page 148 logout, page 178 178 Command reference - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 179
NEW password (8-20 chars) : ******** please confirm account NEW password: ******** password has been changed. See also user, page 301 8/20q Fibre Channel Switch command line interface guide 179 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 180
ping Description Initiates an attempt to communicate with another switch over an Ethernet network and reports the result. Authority None Syntax ping [host_name] -ipv4 [host_address] -ipv6 [host_address] Operands [host_name] DNS host name of the switch you want to query. [host_name] is a character - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 181
service provides an e-mail notification capability for the switch. This service has no relationship with the HP Call Home feature, which notifies HP services Tech_Support_Center profile name is reserved. The Call Home database supports a maximum of 25 profiles. You must enter the callhome guide 181 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 182
,Warn,None) : Format (1=FullText, 2=ShortText) : MaxSize (decimal value, 650-2000000) : EmailSubject (string, max=64 chars, N=None) : Technical problem RecipientEmail (ex: [email protected], N=None) 1. : [email protected] The profile has been created. This configuration must - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 183
the ENTER key to do so. Current Values: Level Alarm Format ShortText MaxSize 1000 EmailSubject Switch Problem RecipientEmail (up to 10 entries allowed) 1. [email protected] New Value (press ENTER to 135 capture, page 138 8/20q Fibre Channel Switch command line interface guide 183 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 184
ps Description Displays current system process information. Authority None Syntax ps Examples The following is an example of the ps command: 8/20q FC Switch #> ps PID PPID %CPU %MEM TIME 244 224 0.0 0.3 00:00:04 245 224 0.0 0.3 00:00:06 246 224 0.0 0.3 00:00:09 247 224 0.0 0.6 00:00:33 248 224 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 185
quit Description Closes the switch connection. Authority None Syntax quit Notes You can also press Control-D to close the switch connection. See also exit, page 148 logout, page 178 8/20q Fibre Channel Switch command line interface guide 185 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 186
the security database and deactivates the active security set. The security configuration value, autosave, and fabric binding remain unchanged. services Resets the switch services configuration to the default values as described in Table 24. snmp Resets the SNMP configuration settings to the factory - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 187
switch reset: • Firmware image files that have not been unpacked • Configuration backup files • Support files system Resets the following system configuration settings to the factory default values: • DNS host configuration parameters. 8/20q Fibre Channel Switch command line interface guide 187 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 188
show setup radius command to display the RADIUS configuration. The default values are shown in Table 23. • Enter the show setup services command to display the switch service configuration. The default values are shown in Table 24. • Enter the show setup system dns command to display the DNS host - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 189
n, where n is the port number False True False False 0 0 True True False False True False Auto False True 8/20q Fibre Channel Switch command line interface guide 189 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 190
Table 20 Port threshold alarm configuration defaults Parameter Default ThresholdMonitoringEnabled False CRCErrorsMonitoringEnabled • RisingTrigger • FallingTrigger • SampleWindow True 25 1 10 DecodeErrorsMonitoringEnabled • RisingTrigger • FallingTrigger • SampleWindow True 25 0 10 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 191
22 SNMP configuration defaults (continued) Parameter Default Description HP StorageWorks 8/20q FC Switch ObjectID 1.3.6.1.4.1.3873.1.11 AuthFailureTrap False 2 seconds 0 False Table 24 Switch services configuration defaults Parameter TelnetEnabled SSHEnabled GUIMgmtEnabled SSLMgmtEnabled - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 192
Table 24 Switch services configuration defaults Parameter MgmtServerEnabled CallHomeEnabled Default True True Table 25 DNS host name configuration defaults Parameter Default DNSClientEnabled False DNSLocalHostname DNSServerDiscovery Static DNSServer1Address - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 193
configuration defaults Parameter AutoSave FabricBindingEnabled PortBindingEnabled Default True False False See also hardreset, page 160 reset, page 186 8/20q Fibre Channel Switch command line interface guide 193 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 194
security Description Opens a Security Edit session in which to manage the security database on a switch. Authority Admin session. The operands active, history, limits, and list are available without an Admin session. Syntax security active cancel clear edit history limits list restore save Operands - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 195
restore Restores the volatile security database with the contents of the non-volatile security database. If the AutoSave parameter is False, you can 2 MaxTotalMembers 1000 19 MaxMembersPerGroup 1000 4 15 [Name] ------ group1 group2 8/20q Fibre Channel Switch command line interface guide 195 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 196
The following is an example of the security list command: 8/20q FC Switch #> security list Active Security Information SecuritySet Group GroupMember No active securityset defined. Configured Security Information SecuritySet Group GroupMember alpha group1 (ISL) 10:00:00:00:00:10:21:16 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 197
than 64 characters. Valid characters are alphanumeric, _, $, ^, and -. The security database supports a maximum of four security sets. deactivate Deactivates the active security set. Close the Security Edit name given by [security_set_new]. 8/20q Fibre Channel Switch command line interface guide 197 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 198
Examples The following is an example of the securityset active command 8/20q FC Switch #> securityset active Active SecuritySet Information ActiveSecuritySet alpha LastActivatedBy Remote LastActivatedOn day month date time year The following is an example of the securityset groups command 8/20q FC - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 199
interruption. Examples The following is an example of the set alarm command: 8/20q FC Switch #> set alarm on 8/20q Fibre Channel Switch command line interface guide 199 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 200
set beacon Description Enables or disables the flashing of the Logged-In LEDs for the purpose of locating a switch. Authority None Syntax set beacon [state] Operands [state] Table 33 describes the beacon state parameters. Table 33 Beacon state parameters Parameter on off Description Enables the - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 201
lasers. Transmission speed: 2 Gb/s, 4 Gb/s, 8 Gb/s, or Auto. The default is Auto. 8-Gb/s SFPs do not support the 1-Gb/s setting. Settting a port to 1 Gb/s that has an 8-Gb/s SFP will down the port. GL, G, F, FL, is enabled. 8/20q Fibre Channel Switch command line interface guide 201 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 202
Table 34 Port configuration parameters (continued) Parameter ARB_FF InteropCredit FANEnable AutoPerfTuning LCFEnable MFSEnable VIEnable MSEnable NoClose IOStreamGuard PDISCPingEnable Description Send ARB_FF (True) instead of IDLEs (False) on the loop. The default is False. Interoperability credit. - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 203
discard this configuration use the config cancel command. See also config, page 142 show config port, page 241 8/20q Fibre Channel Switch command line interface guide 203 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 204
set config security Description Configures the security database for the automatic saving of changes to the active security set and fabric binding. The changes you make with this command are not retained when you reset or power-cycle the switch unless you save them using the config save command. - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 205
effect. To discard this configuration use the config cancel command. See also show config security portbinding, page 243 8/20q Fibre Channel Switch command line interface guide 205 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 206
set config switch Description Sets the switch configuration parameters. The changes you make with this command are not retained when you reset or power-cycle the switch unless you save them using the config save command. Authority Admin session and a Config Edit session Syntax set config switch - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 207
] [8/20q FC Switch] [10000 ] [2000 ] [254 ] [Default Config] See also config, page 142 show config switch, page 244 8/20q Fibre Channel Switch command line interface guide 207 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 208
set config threshold Description Sets the port alarm threshold parameters by which the switch monitors port performance and generates alarms. The changes you make with this command are not retained when you reset or power-cycle the switch unless you save them using the config save command. - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 209
take effect. To discard this configuration use the config cancel command. See also show config threshold, page 245 8/20q Fibre Channel Switch command line interface guide 209 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 210
set config zoning Description Configures the zoning database. The changes you make with this command are not retained when you reset or power-cycle the switch unless you save them using the config save command. Authority Admin session and a Config Edit session Syntax set config zoning Initiates an - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 211
status Monitor none of the component events Monitors all port events Monitors Call Home service events Monitors all SNMP events Monitors switch management events Monitors zoning conflict events display the event display filter parameters. 8/20q Fibre Channel Switch command line interface guide 211 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 212
Table 41 Event display filter parameters Parameter Critical Description Critical severity-level events. The critical level describes events that are generally disruptive to the administration or operation of the fabric, but require no action. Warn Warning severity-level events. The warning level - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 213
administrator intervention. Alarms are always logged and always displayed on the screen. See also show log, page 253 8/20q Fibre Channel Switch command line interface guide 213 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 214
set pagebreak Description Specifies how much information is displayed on the screen at a time. This command is useful for disabling pagebreaks to allow command scripts to run without interruption. Authority None Syntax pagebreak [state] Operands [state] Table 44 describes the pagebreak state - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 215
a device login Disables the port by removing power from the port lasers See also show port, page 265 8/20q Fibre Channel Switch command line interface guide 215 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 216
Home database for managing e-mail notifications of fabric problems. Authority Admin session Syntax set setup callhome Prompts or 6) or DNS host name of the secondary SMTP server. The default is 0.0.0.0. Service port number that the secondary SMTP server is monitoring for SMTP agents. The default is - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 217
Notes • The Callhome service must be active to support Call Home e-mail notification. See the set setup services command. • The primary, secondary, or both SMTP setup? (y/n): See also callhome, page 135 profile, page 181 set setup services, page 221 8/20q Fibre Channel Switch command line interface - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 218
you in a line-by-line fashion to configure attributes that are common to all RADIUS servers. To configure common and server-specific attributes, omit the operand. Table 48 describes the common RADIUS server configuration attributes. Table 48 Common RADIUS server configuration attributes Attribute - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 219
Table 49 Server-specific RADIUS server configuration attributes User Authentication SSL can be enabled using the 'set setup services' command. Current Values: DeviceAuthOrder UserAuthOrder TotalServers Local Local 1 setup? (y/n): [n] 8/20q Fibre Channel Switch command line interface guide 219 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 220
NOTE SSL must be enabled in order to configure RADIUS User Authentication SSL can be enabled using the 'set setup services' command. Server 1 Current Values: ServerIPAddress 10.20.11.8 ServerUDPPort 1812 DeviceAuthServer True UserAuthServer True AccountingServer False Timeout 10 Retries - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 221
and SMI-S. The default is False. • Simple SAN Connection Manager version 1.0 does not support the SSL service. If SSL is enabled, you will be unable to manage the switch using this version EmbeddedGUIEnabled. The default is True. 8/20q Fibre Channel Switch command line interface guide 221 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 222
Table 50 Switch services settings (continued) Parameter SNMPEnabled NTPEnabled CIMEnabled FTPEnabled MgmtServerEnabled CallHomeEnabled True. Enables (True) or disables (False) the Call Home service which controls e-mail notification. The default is True. NOTE: The 8/20q Fibre Channel Switch Call - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 223
#> set setup services A list of configuration may be required after enabling a service. * If services are disabled, the connection to the switch Do you want to save and activate this services setup? (y/n): [n] See also show setup services, page 273 8/20q Fibre Channel Switch command line - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 224
can be up to 64 characters excluding #, semicolon (;), and comma (,). The default is undefined. This value is also passed to the Call Home service configuration. Specifies the name of the switch location. The name can be up to 64 characters excluding #, semicolon (;), and comma (,). The default is - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 225
(True / False) : ProxyEnabled (True / False) : SNMPv3Enabled (True / False) : Do you want to save and activate this snmp setup? (y/n): [n] 8/20q Fibre Channel Switch command line interface guide 225 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 226
The following is an example of the set setup snmp trap command: 8/20q FC Switch (admin) #> set setup snmp trap 1 A list of attributes with formatting and current values will follow. Enter a new value or simply press the ENTER key to accept the current value. If you wish to terminate this process - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 227
unqualified host names to extend the DNS search. You can specify up to five search lists (or suffixes). 8/20q Fibre Channel Switch command line interface guide 227 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 228
ipv4 Prompts you in a line-by-line fashion to change the switch IPv4 Ethernet configuration parameters described in Table 54. To configure all system parameters, omit the operand. For each parameter, enter a new value or press Enter to accept the current value. NOTE: Changing the IP address will - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 229
True. Enables (True) or disables (False) the recording of the switch event log on a remote host that supports the syslog protocol. The default is False. The IP address (version 4 or 6) or DNS host name of the to accept the current value. 8/20q Fibre Channel Switch command line interface guide 229 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 230
Table 58 Timer configuration parameters Parameter AdminTimeout Description Amount of time in minutes the switch waits before terminating an idle Admin session. Zero (0) disables the time out threshold. The default is 30, the maximum is 1440. InactivityTimeout Amount of time in minutes the switch - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 231
(IPv6 Address/Mask Length format) : EthIPv6GatewayAddress (IPv6 Address) : Do you want to save and activate this system setup? (y/n): [n] 8/20q Fibre Channel Switch command line interface guide 231 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 232
The following is an example of the set setup system logging command: 8/20q FC Switch (admin) #> set setup system logging A list of attributes with formatting and current values will follow. Enter a new value or simply press the ENTER key to accept the current value. If you wish to terminate this - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 233
, 0=never) : Do you want to save and activate this system setup? (y/n): [n] See also show setup system, page 275 8/20q Fibre Channel Switch command line interface guide 233 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 234
set switch state Description Changes the administrative state for all ports on the switch. The previous set config switch command settings are restored after a switch reset or a reactivation of a switch configuration. Authority Admin session Syntax set switch state [state] Operands [state] Table 59 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 235
/Center Enter selection (or 'q' to quit): america/north_dakota/center See also date, page 147 show timezone, page 283 8/20q Fibre Channel Switch command line interface guide 235 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 236
show about Description Displays introductory information about the operational attributes of the switch. This command is equivalent to the show version command. Authority None Syntax show about Table 60 describes the information returned by the show about command. Table 60 Show about display - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 237
EthIPv4NetworkAddress EthIPv6NetworkAddress MACAddress WorldWideName ChassisSerialNumber SymbolicName ActiveSWVersion ActiveTimestamp POSTStatus LicensedPorts SwitchMode See also show version, page 286 HP StorageWorks 8/20q Fibre Channel Switch 10.20.11.192 :: 00:c0:dd:00:71:ee 10 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 238
show alarm Description Displays the alarm log and session output stream display setting. Authority None Syntax show alarm settings Operands settings Displays the status of the parameter that controls the display of alarms in the session output stream. This parameter is set using the set alarm - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 239
of the show broadcast command: 8/20q FC Switch #> show broadcast Group Member Ports ISL Ports 0 3 16 15 16 8/20q Fibre Channel Switch command line interface guide 239 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 240
show chassis Description Displays chassis component status and temperature. Authority None Syntax show chassis Examples The following is an example of the show chassis command. 8/20q FC Switch #> show chassis Chassis Information BoardTemp (1) - Degrees Celsius BoardTemp (2) - Degrees Celsius - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 241
Port3 False True False False 0 0 True True True False Auto True See also set config port, page 201 8/20q Fibre Channel Switch command line interface guide 241 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 242
show config security Description Displays the security database configuration parameters. Authority None Syntax show config security Examples The following is an example of the show config security command: 8/20q FC Switch #> show config security Configuration Name: default Switch Security - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 243
. No port binding entries found. No port binding entries found. See also set config security portbinding, page 205 8/20q Fibre Channel Switch command line interface guide 243 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 244
show config switch Description Displays the switch configuration parameters. Authority None Syntax show config switch Examples The following is an example of the show config switch command: 8/20q FC Switch #> show config switch Configuration Name: default Switch Configuration Information - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 245
RisingTrigger 5 FallingTrigger 1 SampleWindow 10 LOSMonitoringEnabled True RisingTrigger 100 FallingTrigger 5 SampleWindow 10 See also set config threshold, page 208 8/20q Fibre Channel Switch command line interface guide 245 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 246
show config zoning Description Displays zoning configuration parameters for the switch. Authority None Syntax show config zoning Examples The following is an example of the show config zoning command: 8/20q FC Switch #> show config zoning Configuration Name: default Zoning Configuration - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 247
:00:60:69:50:0b:6c Domain 104 (0x68) WWN = 10:00:00:c0:dd:00:b8:b7 8/20q Fibre Channel Switch command line interface guide 247 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 248
show donor Description Displays list of current donor and extended credit configuration for all ports. Authority None Syntax show donor Examples The following is an example of the show donor command: 8/20q FC Switch #> show donor Port Config Ext Credit Max Credit Donated Member of Valid Groups to - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 249
3.58 13.31 1.38 1.68 2.02 1.99 2.84 See also show temp, page 281 show voltage, page 288 8/20q Fibre Channel Switch command line interface guide 249 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 250
show fabric Description Displays list of each domain, symbolic name, worldwide name, node IP address, and port IP address in the fabric. Authority None Syntax show fabric brief Operands brief Displays a table of switches in the fabric including domain ID, WWN, and symbolic name. If you omit the - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 251
21:01:00:e0:8b:27:aa:bc SupportedFC4Types SupportedSpeed CurrentSpeed MaximumFrameSize OSDeviceName HostName FCP 2Gb/s 2Gb/s 2048 8/20q Fibre Channel Switch command line interface guide 251 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 252
show interface Description Displays the status of the active network interfaces. Authority None Syntax show interface Examples The following is an example of the show interface command: 8/20q FC Switch #> show interface eth0 Link encap:Ethernet HWaddr 00:C0:DD:00:00:27 inet addr:10.20.116. - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 253
show log Description Displays the contents of the log or the parameters used server events Name server events Miscellaneous events Port events Call Home service events SNMP events Switch management events Zoning conflict events display [filter Fibre Channel Switch command line interface guide 253 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 254
Table 62 Event log display filter parameters Parameter Info Description Displays all informative events Warning Displays all warning events Critical Displays all critical events Eport Displays all events related to E_Ports Mgmtserver Displays all events related to the management server - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 255
] [335][day month date time year][I][Eport Port: 0/8][LSDB Xchg timer set] See also set log, page 211 8/20q Fibre Channel Switch command line interface guide 255 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 256
show lsdb Description Displays link state database information, Authority None Syntax show lsdb Examples The following is an example of the show lsdb command: 8/20q FC Switch #> show lsdb Link State Database Information LsID 34: Age=1176, Incarnation=0x800000e5 NeighborDomain=36, LocalPort=6, - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 257
all ports that have transceivers installed. Notes Table 63 describes the transceiver information in the show media display. 8/20q Fibre Channel Switch command line interface guide 257 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 258
, and distance. The media designator may be M5 (multimode 50 micron), M6 (multimode 62.5 micron), or MX. MX indicates that the media supports both multimode 50 and 62.5 micron. MediaType may also be one of the following: • NotInstalled-transceiver is not installed. • Unknown-transceiver does - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 259
14.00 0.637 0.791 LowWarning -20.00 2.90 2.00 0.082 0.028 LowAlarm -25.00 2.70 1.00 0.073 0.019 8/20q Fibre Channel Switch command line interface guide 259 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 260
show mem Description Displays information about memory activity. Authority None Syntax show mem [count] Operands [count] The number of seconds for which to display memory information. If you omit [count], the value 1 is used. Displayed memory values are in 1K block units. NOTE: This operand will - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 261
diskarray7.anycompany.com ClassOfService 3 PortIPAddress :: FabricPortName 20:01:00:c0:dd:00:bc:56 FC4Type FCP FC4Desc (NULL) 8/20q Fibre Channel Switch command line interface guide 261 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 262
show pagebreak Description Displays the current pagebreak setting. Authority None Syntax show pagebreak Operands The pagebreak setting limits the display of information to 20 lines (ON) or allows the continuous display of information without a break (OFF). Examples The following is an example of the - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 263
omit [port_list], the command displays performance data for ports 0-15. Type q and press Enter to stop the display. 8/20q Fibre Channel Switch command line interface guide 263 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 264
outframe [port_list] Displays continuous performance data in frames/second transmitted for the ports given by [port_list]. [port_list] can be a set of port numbers and ranges delimited by spaces. For example, 0 2 10-15 specifies ports 0, 2, 10, 11, 12, 13, 14, and 15. If you omit [port_list], the - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 265
loop initialization Number of times the port entered initialization and the initialization failed Application-specific integrated circuit (ASIC) number ASIC port number Number of frames that have framing errors delivery of this frame. 8/20q Fibre Channel Switch command line interface guide 265 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 266
Number of F7, Arbitrated Loop Source Address (AL_PS) Loop Initialization Primitives (LIPs), or Arbitrated Loop Destination Address (AL_PD) (vendor specific) resets performed Number of LIP frames that reinitialized the loop. An L_Port, identified by AL_PS, may have noticed a performance degradation - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 267
50 micron), M6 (multimode 62.5 micron), or MX. MX indicates that the media supports both multimode 50 and 62.5 micron. Transceiver manufacturer Transceiver manufacturer identifier Operational state AutoPerfTuning status: True, False. 8/20q Fibre Channel Switch command line interface guide 267 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 268
Examples The following is an example of the show port command: 8/20q FC Switch #> show port 1 Port Number: 1 ------------ AdminState Online OperationalState Offline AsicNumber 0 PerfTuningMode Normal AsicPort 2 PortID 3a0100 ConfigType GL PortWWN 20:01:00:c0:dd:0d:4f:08 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 269
: . . . 2 of 53 day mmm dd hh:mm:ss yyyy 6 TEST_SUITE_POST (0x13) TEST_STATIC_PORTADDR (0x72) DIAGS_ERR_CPORT_VERIFY (0x34) 0 0/0 0x00000005 0x0082202b 0x00a2202b 8/20q Fibre Channel Switch command line interface guide 269 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 270
database configuration. NOTE: The 8/20q Fibre Channel Switch Call Home service provides an e-mail notification capability for the switch. This service has no relationship with the HP Call Home feature, which notifies HP services. Authority None Syntax show setup callhome Examples The following is - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 271
FC Switch #> show setup mfg Manufacturing Information BrandName HP BuildDate Tuesday, September 25, 2007 11:23 ChassisPartNumber FC Switch SwitchWWN 10:00:00:c0:dd:0d:53:e7 SystemDescription HP StorageWorks 8/20q Fibre Channel Switch SystemObjectID 1.3.6.1.4.1.3873.1.11 8/20q Fibre - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 272
[server_number] Operands common Displays the configuration parameters that are common for all RADIUS servers. To display common and server-specific information, omit the operand. See Table 48 for a description of the common configuration parameters. server [server_number] Displays the configuration - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 273
an example of the show setup services command: 8/20q FC Switch #> show setup services System Services TelnetEnabled True SSHEnabled False GUIMgmtEnabled True MgmtServerEnabled True CallHomeEnabled True See also set setup services, page 221 8/20q Fibre Channel Switch command line - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 274
trap-specific configuration parameters. Examples The following is an example of the show setup snmp common command: 8/20q FC Switch #> show setup snmp common SNMP Information SNMPEnabled True Contact Location Description HP StorageWorks - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 275
DNSSearchListDiscovery DNSSearchList1 DNSSearchList2 DNSSearchList3 DNSSearchList4 DNSSearchList5 False Static Static 8/20q Fibre Channel Switch command line interface guide 275 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 276
The following is an example of the show setup system ipv4 command: 8/20q FC Switch #> show setup system ipv4 System Information EthIPv4NetworkEnable EthIPv4NetworkDiscovery EthIPv4NetworkAddress EthIPv4NetworkMask EthIPv4GatewayAddress True Static 10.20.11.32 255.255.252.0 10.20.8.254 The - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 277
/18 5 18/16/18/16 6 16/18/16/18 7 16/18/16/18 15 18/16/18/16 8/20q Fibre Channel Switch command line interface guide 277 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 278
, used to record events in the event log Number of ports available on the switch Number of times the switch has been reset over its service life Action that caused the last reset Active firmware image version and build date Firmware image version and build date that is pending. This image - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 279
00000000 Passed 00000000 NeverRun 32 Normal See also set config switch, page 206 set switch state, page 234 8/20q Fibre Channel Switch command line interface guide 279 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 280
show system Description Displays the operational status of the Ethernet and DNS host name configuration parameters. Authority None Syntax show system Examples The following is an example of the show system command: 8/20q FC Switch #> show system Assigned System Network Information Hostname < - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 281
--------- 65 n/a 65 95 High Alarm ---------- 70 n/a 70 100 See also show env, page 249 show voltage, page 288 8/20q Fibre Channel Switch command line interface guide 281 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 282
show testlog Description Displays the contents of the diagnostic field test log file. Authority None Syntax show testlog or show test log Examples The following is an example of the show - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 283
of the show timezone command: 8/20q FC Switch #> show timezone America/Chicago See also set timezone, page 235 8/20q Fibre Channel Switch command line interface guide 283 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 284
show topology Description Displays all connected devices. Authority None Syntax show topology [port_number] Operands [port_number] Displays the devices connected to the port given by [port_number]. Examples The following is an example of the show topology command: 8/20q FC Switch #> show - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 285
-session2 Unknown snmp@OB-session3 Unknown admin@OB-session5 10.33.21.27 See also user, page 301 8/20q Fibre Channel Switch command line interface guide 285 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 286
show version Description Displays introductory information about the operational attributes of the switch. This command is equivalent to the show about command. Authority None Syntax show version Notes Table 67 describes the information returned by the show version command. Table 67 Show version - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 287
show version * * * Command Line Interface SHell (CLISH) * * * SystemDescription HP StorageWorks 8/20q Fibre Channel Switch HostName EthIPv4NetworkAddress 10.20.11.192 EthIPv6NetworkAddress :: about, page 236 8/20q Fibre Channel Switch command line interface guide 287 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 288
show voltage Description Displays voltage information. Authority None Syntax show voltage Examples 8/20q FC Switch #? show voltage Voltage Sensors: Sensor ------ 0 1 2 3 4 5 6 7 8 Description ----------2.5V 1.25V 3.3V 12V 1.2V 1.5V 1.8V_ANALOG 1.8V 2.5V_ANALOG Status -----Good Good Good Good - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 289
this command. Authority Admin session Syntax shutdown Notes When the shutdown is complete, the Heartbeat LED is extinguished. 8/20q Fibre Channel Switch command line interface guide 289 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 290
snmpv3user Description Manages SNMP version 3 user accounts on the switch. Authority Admin session except for the list operand Syntax snmpv3user add delete [account] edit list Operands add Creates an SNMP version 3 user account, prompting you for the parameters that are described in Table 68. - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 291
(True/False) [True ] : f Do you want to save and activate this setup ? (y/n): [n] y SNMPV3 user account edited and activated. 8/20q Fibre Channel Switch command line interface guide 291 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 292
The following is an example of the snmpv3user list command: 8/20q FC Switch #> snmpv3user list Username -------snmpuser1 See also set setup snmp, page 224 show setup snmp, page 274 Group ----ReadWrite AuthType -------MD5 PrivType -------DES 292 Command reference - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 293
: 8/20q FC Switch (admin) #> test cancel port 15 See also test port, page 294 test status, page 296 8/20q Fibre Channel Switch command line interface guide 293 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 294
test port Description Tests individual ports using an offline or online test. Authority Admin session Syntax test port [port_number] offline [loopback_type] online Operands [port_number] The port to be tested. [port_number] can be 0-19. offline [loopback_type] Performs an offline test of the type - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 295
) #> Test for port 1 Passed. See also test cancel, page 293 test status, page 296 test switch, page 298 8/20q Fibre Channel Switch command line interface guide 295 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 296
test status Description Displays the status of a test in progress, or if there is no test in progress, the status of the last test that was executed. Authority None Syntax test status port [port_number] switch Operands port [port_number] Display test status for the port given by [port_number]. [ - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 297
See also test cancel, page 293 test port, page 294 test switch, page 298 8/20q Fibre Channel Switch command line interface guide 297 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 298
test switch Description Tests all ports on the switch using a connectivity test, an offline test, or an online test. Authority Admin session Syntax test switch connectivity [loopback_type] offline [loopback_type] online Operands connectivity [loopback_type] Performs a connectivity test of the type - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 299
to start the test? (y/n) [n] y See also test cancel, page 293 test status, page 296 test switch, page 298 8/20q Fibre Channel Switch command line interface guide 299 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 300
uptime Description Displays the elapsed up time since the switch was last reset and the reset method. A hot reset or non-disruptive firmware activation does not reset the elapsed up time reported by this command. Authority None Syntax uptime Examples The following is an example of the uptime command - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 301
, expires in < 50 days) gregj (admin authority = True , expires in < 100 days) fred (admin authority = True , never expires) 8/20q Fibre Channel Switch command line interface guide 301 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 302
The following is an example of the user add command: 8/20q FC Switch (admin) #> user add Press 'q' and the ENTER key to abort this command. account name (1-15 chars) : user1 account password (8-20 chars) : ******* please confirm account password: ******* set account expiration in days (0-2000 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 303
session. Authority None Syntax whoami Examples The following is an example of the whoami command: 8/20q FC Switch #> whoami User name : admin@session2 Switch name : HP StorageWorks 8/20q Fibre Channel Switch Switch domain ID: 21 (0x15) 8/20q Fibre Channel Switch command line interface - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 304
[zone]. A zone name must begin with a letter and be no longer than 64 characters. Valid characters are alphanumeric, _, $, ^, and -. The zoning database supports a maximum of 2,000 zones. You must enter the zoning save command to save your changes. delete [zone] Deletes the specified zone given by - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 305
example of the zone orphans command: 8/20q FC Switch #> zone orphans Current list of orphan zones zone3 zone4 8/20q Fibre Channel Switch command line interface guide 305 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 306
The following is an example of the zone zonesets command: 8/20q FC Switch #> zone zonesets zone1 Current List of ZoneSets for Zone: zone1 zone_set_1 See also zoneset, page 307 zoning edit, page 314 306 Command reference - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 307
and be no longer than 64 characters. Valid characters are alphanumeric, _, $, ^, and -. The zoning database supports a maximum of 256 zone sets. You must enter the zoning save command to save your changes. deactivate save your changes. 8/20q Fibre Channel Switch command line interface guide 307 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 308
rename [zone_set_old] [zone_set_new] Renames the zone set given by [zone_set_old] to the name given by [zone_set_new]. You can rename the active zone set. You must enter the zoning save command to save your changes. zones [zone_set] Displays all zones that are components of the zone set given by [ - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 309
NVRAM. Please confirm (y/n): [n] y The active zoning database has been saved. See also zone, page 304 zoneset, page 307 8/20q Fibre Channel Switch command line interface guide 309 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 310
zoning cancel Description Closes the current Zoning Edit session. Any unsaved changes are lost. Authority Admin session and a Zoning Edit session. Syntax zoning cancel Examples The following is an example of the zoning cancel command: 8/20q FC Switch #> admin start 8/20q FC Switch (admin) #> zoning - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 311
Switch (admin-zoning) #> zoning clear 8/20q FC Switch (admin-zoning) #> zoning save See also zoning save, page 321 8/20q Fibre Channel Switch command line interface guide 311 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 312
zoning configured Description Displays the contents of the non-volatile zoning database. Authority None Syntax zoning configured Examples The following is an example of the zoning configured command: 8/20q FC Switch #> - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 313
all zonesets, zones, and aliases that are not currently active. Please confirm (y/n): [n] y 8/20q FC Switch (admin) #> zoning save 8/20q Fibre Channel Switch command line interface guide 313 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 314
zoning edit Description Opens a Zoning Edit session for the non-volatile zoning database or merged zone set in which to create and manage zone sets and zones. Authority Admin session Syntax zoning edit [database] Operands [database] Opens an edit session for the zoning database given by [database]. - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 315
zoning edited Description Displays the contents of the edited zoning database. Authority Admin session and a Zoning Edit session Syntax zoning edited Examples The following is an :00:c0:dd:00:b9:fa See also zoning configured, page 312 8/20q Fibre Channel Switch command line interface guide 315 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 316
zoning history Description Displays a history of zoning modifications. This operand does not require an Admin session. History information includes the following: • Time of the most recent zone set activation or deactivation and the user who performed it • Time of the most recent modifications to - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 317
maximum. Maximum number of members in a zone is 2,000. Maximum number of members in an alias is 2,000. 8/20q Fibre Channel Switch command line interface guide 317 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 318
zoning list Description Lists all zoning definitions, including the applicable zoning database. Authority None Syntax zoning list Examples The following is an example of the zoning list command: 8/20q FC Switch #> zoning list Active (enforced) ZoneSet Information ZoneSet Zone ZoneMember - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 319
enter the zoning save command to save your changes. If you omit this operand, this command displays the contents of the merged zone set. Examples The following is an example of the zoning merged command: 8/20q 315 zoning list, page 318 8/20q Fibre Channel Switch command line interface guide 319 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 320
zoning restore Description Restores the volatile zoning database with the contents of the non-volatile zoning database. If the MergeAutoSave parameter is False (see Table 21), you can use this command to revert changes to the - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 321
must be activated before they can take effect -- see zoneset activate command. See also zoning edit, page 314 8/20q Fibre Channel Switch command line interface guide 321 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 322
322 Command reference - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 323
131 message queue 117, 121 messages 112 queue 112 requirements 111 resetting 115 service 111, 114, 222 technical support interface 113 Callhome command 135 Changeover example Clear example 122 Edit example 115 History 66 command entry 16 8/20q Fibre Channel Switch command line interface guide 323 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 324
Check Create command 145 Certificate example 89 Support example 17 credit donor 248 critical - See Domain Name System documentation conventions 12 HP web site 11 domain ID binding 155, 157 105, 107 displaying configuration 108 displaying contents 106 filtering 107 restoring configuration 108 event - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 325
files 19, 50 downloading firmware 55 restoring configuration file 50 service 222 user account 21 firmware 54, 163 activation 54 adapter 251 hot reset 53 Hotreset command 163 HP storage web site 13 Subscriber's choice web site 13 technical support 13 I I/O Stream Guard 202 idle interface guide 325 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 326
port initialization 177 loss-of-signal errors 69 M MAC See Media Access Control maintenance mode 21 Management Server group 91, 98, 156 service 222 manufacturer information 271 mask address 228 MD5 authentication 154 Media Access Control address 236 memory activity 260 message format 112 queue 117 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 327
Secure Shell description 87 service 87, 221 Secure Socket Layer certificate 89, 145 description 87 service 87, 221 switch time security database autosave 95 clearing 194 configuration 95 description 91 displaying contents 91, 194 displaying history 94, 194 displaying limits 94, interface guide 327 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 328
97 Copy example 97 Create example 96 Deactivate example 97 Delete example 97 Group example 93 List example 91 Remove example 97 Rename example 97 services displaying 46, 88 managing 46 Set Beacon command 51 Set Config Port command 201 example 65 Set Config Security command 204 example 95 Set Config - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 329
steering 277 Storage Management Initiative-Specification 222 subnet mask 25 Subscriber's choice, HP 13 support file 145 creating 17 downloading 18 process information 42 T technical support, HP 13, 17 Telnet connection security 87 logging in 15 service 221 session timeout 230 test guide 329 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 330
stability 13 severity level 105 web applet service 221 web sites HP documentation 11 HP storage 13 HP Subscriber's choice 13 Whoami command 303 workstation components 79 displaying configuration parameters 43, 246 displaying contents 73, 318 displaying limits 79, 317 displaying modification history - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 331
318 example 74 Zoning Merged command 319 Capture example 81 Zoning Restore command 320 Zoning Save command 321 8/20q Fibre Channel Switch command line interface guide 331 - HP StorageWorks 8/20q | HP StorageWorks 8/20q Fibre Channel Switch command line - Page 332
332 Index
HP StorageWorks
8/20q Fibre Channel Switch command line
interface guide
Part number: 5697-7760
Third edition: January 2009