- HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 1
HP StorageWorks 8Gb SAN Switch hardware reference manual 5697-7478 Part number: 5697-7478 First edition: June 2008 - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 2
Confidential computer software. Valid license from HP required for possession, use or copying. Consistent HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 3
HP StorageWorks 8Gb SAN Switch models 13 Power Pack+ models 14 8/8 and 8/24 SAN Switch features 14 Port side of the 8/8 and 8/24 SAN Switch 15 Nonport side of the 8/8 and 8/24 SAN Switch 15 Activating additional 8/8 and 8/24 SAN Switch ports 15 Enabling E_Ports on the 8/8 SAN Switch 15 8/40 - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 4
47 8Gb SAN Switch LEDs 48 8/8 and 8/24 SAN Switch LEDs 48 8/40 SAN Switch LEDs 49 8/80 SAN Switch LEDs 50 Port side LED activity for the 8/80 SAN Switch 51 Nonport side LED activity for the 8/80 SAN Switch 53 Interpreting POST results 54 Maintaining the 8Gb SAN Switch 54 Installing an SFP - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 5
78 Lithuanian notice 79 Polish notice 79 Portuguese notice 79 Slovakian notice 79 Slovenian notice 80 Spanish notice 80 Swedish notice 80 B Electrostatic discharge 81 How to prevent electrostatic discharge 81 Grounding methods 81 Index 83 8Gb SAN Switch hardware reference manual 5 - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 6
8/24 SAN Switch 15 2 Port side view-8/40 SAN Switch 16 3 Nonport side view-8/40 SAN Switch 17 4 Port side view-8/80 SAN Switch 18 5 Nonport side view-8/80 SAN Switch 19 6 Trunking groups example 21 7 8/40 SAN Switch shipping carton contents 26 8 Installing the rear mounting brackets (HP 10000 - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 7
18 EMC compatibility 65 19 Power supply specifications 65 20 Laser data transmission ranges for the 8/8 and 8/24 SAN Switches 66 21 Laser data transmission ranges for the 8/40 SAN Switch 67 22 Laser data transmission ranges for the 8/80 SAN Switch 68 8Gb SAN Switch hardware reference manual 7 - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 8
8 - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 9
• HP StorageWorks 8/8 SAN Switch • HP StorageWorks 8/24 SAN Switch • HP StorageWorks 8/40 SAN Switch • HP StorageWorks 8/80 SAN Switch Intended audience This guide is intended for system administrators and technicians with knowledge of: • Storage area networks (SANs) • HP StorageWorks Fibre Channel - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 10
text: Table 1 Cross-reference links and e-mail addresses Blue, underlined text: http://www.hp.com Bold text Website addresses • Keys that are pressed • Text typed into a GUI IMPORTANT: Provides clarifying information or specific instructions. NOTE: Provides additional information. 10 About this - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 11
(CSR) programs allow you to repair your StorageWorks product. If a CSR part needs replacing, HP ships the part directly to you so that you can install it at your convenience. Some parts do not qualify for CSR. Your HP-authorized service provider will determine whether a repair can be accomplished - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 12
http://www.hp.com/support/manuals • http://www.hp.com/support/downloads Documentation feedback HP welcomes your feedback. To make comments and suggestions about product documentation, please send a message to [email protected]. All submissions become the property of HP. 12 About this guide - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 13
. • HP StorageWorks 8/24 SAN Switch-Ships with 16 ports activated and includes a Full Fabric license. It includes Advanced Web Tools, Advanced Zoning, and Enhanced Group Manager (EGM) as standard software components. • HP StorageWorks 8/40 SAN Switch-Ships with 24 ports activated and includes a Full - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 14
, see the HP StorageWorks Fabric OS administrator guide for the firmware version you are running. 8/8 and 8/24 SAN Switch features • Functions as an edge device in fabrics of up to 239 switches. • Integrates a single motherboard design with 667 MHz PowerPC 440EPx Reduced Instruction Set Computer - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 15
activating Port Upgrade licenses, page 20. Enabling E_Ports on the 8/8 SAN Switch The 8/8 SAN Switch model requires that you purchase the HP StorageWorks Full Fabric Upgrade License, part number T4261A, to enable E_Ports (the 8/24 SAN Switch ships with the Full Fabric license installed). By default - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 16
8/40 SAN Switch features • Provides the EZSwitchSetup Wizard for easy setup and basic configuration. • Support for 1, 2, 4, and 8Gbps autosensing Fibre Channel switch and router ports. • Integrates a single motherboard design with 667 MHz PowerPC 440EPx Reduced Instruction Set Computer (RISC) CPU and - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 17
40 SAN Switch Activating additional 8/40 SAN Switch ports By default, the 8/40 SAN Switch model integrates 24 licensed ports (ports 0 through 23). To enable additional ports, you must purchase and install the HP Storage Works 8/40 SAN Switch 8Gb 8-port Upgrade LTU (part number T5519A): • To enable - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 18
port 6 USB port 7 FC ports 0-7 8 FC ports 8-15 12 11 26456a 9 FC ports 16-23 10 FC ports 24-31 11 FC ports 32-38 12 FC ports 40-47 13 FC ports 48-55 14 FC ports 56-63 15 FC ports 64-71 16 FC ports 72-79 Figure 4 Port side view-8/80 SAN Switch 18 Introducing the HP StorageWorks 8Gb SAN Switch - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 19
80 SAN Switch Activating additional 8/80 SAN Switch ports By default, the 8/80 SAN Switch model integrates 48 licensed ports (ports 0 through 47). To enable additional ports, you must purchase and install the HP StorageWorks 8/80 SAN Switch 8Gb 16-port Upgrade LTU (part number T5520A): • To enable - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 20
command, which enables the port laser. For example: portstart 16-31 6. Issue the portenable command to enable the ports. For example: portenable 16-31 7. Optional: Issue the portshow command to verify that the newly activated ports are started. 20 Introducing the HP StorageWorks 8Gb SAN Switch - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 21
ISL Trunking groups All 8Gb SAN Switch models support Inter-Switch Link (ISL) Trunking as an optional, licensed feature. When this feature is enabled, create trunked groups of up to eight contiguous ports. For example, the Fibre Channel ports on the SAN Switch are numbered from left to right and - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 22
Table 4 HP 4Gb Short Wave B-Series FC SFP 1 Pack, order number AJ715A Distance OM2 cable OM3 cable 4Gb performance 150 meters 270 meters 2Gb performance 300 meters 500 meters 1Gb performance 500 meters 860 meters 22 Introducing the HP StorageWorks 8Gb SAN Switch - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 23
Optional software kits Option Part number HP StorageWorks Full Fabric Upgrade License T4261A HP Storage Works 8/8 and 8/24 SAN Switch 8Gb 8-port Upgrade LTU T5518A HP StorageWorks 8/80 SAN Switch 8Gb 16-port Upgrade LTU T5520A HP Storage Works 8/40 SAN Switch 8Gb 8-port Upgrade LTU T5519A - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 24
, order number: 221691-B26 nl 50 m LC-SC multi-mode FC Cable, order number: 221691-B27 NOTE: To obtain the latest information on hardware and software components, go to the B-Series section of the following HP website: nl http://www.hp.com/go/san. 24 Introducing the HP StorageWorks 8Gb SAN Switch - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 25
27 • Items required for installation, page 28 • Installing the switch as a stand-alone device, page 29 • Installing the switch using the SAN Switch Rack Mount Kit, page 30 • Cabling and configuring the SAN Switch, page 39 • Connecting the SAN Switch to the fabric, page 39 Shipping carton contents - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 26
Number Description One accessory kit, containing the following items: • One set of HP StorageWorks product documentation, including HP StorageWorks 8Gb SAN Switch quick start instructions, HP StorageWorks SAN Switch Rack Mount Kit installation instructions, Read Me First, Safety Guides, User - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 27
on page 29. • HP highly recommends mounting the switch in one of the following HP customized racks • HP System/e Rack • HP 10000 G2 Series Rack and HP 10000 Series Rack See "Installing the switch using the SAN Switch Rack Mount Kit" on page 30 for detailed instructions. Electrical considerations For - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 28
groups must meet specific requirements, as described in the HP StorageWorks Fabric OS administrator guide. • For easier maintenance, label the fiber optic cables, and record the devices to which they are connected. • Keep LEDs visible by routing port cables and other cables away from the LEDs. • Use - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 29
described in "Powering the 8/8 or 8/24 SAN Switch on and off" on page 47 or "Powering the 8/40 or 8/80 SAN Switch on and off" on page 47. CAUTION: Do not connect the switch to the network until the IP address is set. See "Set the IP address" on page 42. 8Gb SAN Switch hardware reference manual 29 - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 30
air from within the rack. A plenum ships with the following 8Gb SAN Switch models only: • 8/8 SAN Switch • 8/24 SAN Switch See "Installing the plenum (if required)" on page 36 for complete instructions on how to install a plenum. Installation and safety guidelines Verify that the rack and the area - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 31
install the switch in a rack: • SAN Switch or MP Router • Power cables • #2 Phillips screwdriver • 7/16-inch wrench or socket • Plenum (if required). For 8Gb models, a plenum is required for 8/8 and 8/24 SAN Switches only. • SAN Switch lock for use with the SAN Switch 2/32 only. 14 SAN Switch must - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 32
pan-head screws and two #10 alignment washers, as shown in Figure 9. Figure 8 Installing the rear mounting brackets (HP 10000 series racks) Figure 9 Installing the rear mounting brackets (HP System/e Rack) NOTE: Your SAN Switch Rack Mount Kit contains both right rails and left rails. The rails are - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 33
. Then install two #10-32 x 1/2-inch Phillips pan-head screws with captive star lock-washers and two #10 adapter washers in the upper and lower hole locations of the left rail. See Figure 11. Figure 11 Assembling the outer rails (HP 10000 series racks) 8Gb SAN Switch hardware reference manual 33 - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 34
16 SAN Switch, SAN Switch 4/32 Ten (Five per rail) N/A 4/32B SAN Switch Six (Three per rail) N/A MP Router Six (Three per rail) 4/64 SAN Switch or 400 MP Router Ten (Five per rail) N/A 8/8 SAN Switch, 8/24 SAN Switch, 8/40 SAN Switch, 8/80 SAN Switch Ten (Five per rail) 34 Installing and - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 35
rails to the 4/8, 4/16, 8/8, or 8/24 SAN Switches, use the five screw holes marked 8. The plenum requires one screw hole marked 8 and one screw hole marked 16, as shown in Figure 15 on page 37. d. To attach the inner rails to the 4/32, 4/32B, 4/64, 8/40, 8/80 SAN Switch or 400 MP Router, use the - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 36
ships in the switch accessory kit: • SAN Switch 2/8V • SAN Switch 2/16 • SAN Switch 2/16V • 4/8 SAN Switch • 4/16 SAN Switch • 4/32B SAN Switch • 8/8 SAN Switch • 8/24 SAN Switch See "Installing the plenum (if required)" on page 36 for complete installation instructions. If not installing one of the - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 37
a switch in HP 9000 Series, HP 10000 Series, or HP System/e racks. 2. Insert the device into the rack, and install one #10-32 x 1/2-inch Phillips pan-head screw with captive star lock washer. Repeat for the remaining side. See Figure 16 and Figure 17. 8Gb SAN Switch hardware reference manual 37 - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 38
Figure 16 Securing the switch (HP 9000 Series or HP 10000 Series Racks) Figure 17 Securing the device in an HP System/e Rack 3. Tighten the hex nuts installed in step 4, page 33. See Figure 10, page 33. This completes the rack mount procedure. 38 Installing and configuring an 8Gb SAN Switch - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 39
and fabric. For instructions on configuring the switch to operate in a fabric containing switches from other vendors, see the HP StorageWorks Fabric OS administrator guide. For more information about the commands used in this procedure, see the Fabric OS command reference manual for the Fabric OS - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 40
-232 connector, remove the adapter on the end of the serial cable, and insert the exposed RJ-45 connector into the RJ-45 serial port on the workstation. HP StorageWorks 8/40 SAN Switch 0 41 2 5 3 6 7 8 12 9 13 10 14 11 15 16 20 17 21 18 22 19 23 24 28 25 29 26 30 27 31 32 - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 41
/ttyb -9600 nl If ttyb is already in use, use ttya instead and enter the following string at the prompt: tip /dev/ttya -9600 8Gb SAN Switch hardware reference manual 41 - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 42
admin and the default password is password. Create up to two simultaneous admin sessions and four user sessions. For more details, see the HP StorageWorks Fabric OS administrator guide and the Fabric OS command reference manual for the Fabric OS running on your switch. Set the switch IP address You - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 43
SAN Switch with an incorrect date and time value still functions properly. However, it is important that your switch shows the accurate date and time, because these are used for logging, error detection, and troubleshooting. 1. Log in to the switch using the default password, (password). 2. Enter - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 44
FCS switch are propagated to all switches in the fabric. For more information on using an NTP server, and IPv6 considerations, see the HP StorageWorks Fabric OS 6.1.x administrator guide. 1. Log in to the switch using the default password: password. 44 Installing and configuring an 8Gb SAN Switch - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 45
. The command uploads the switch configuration to the server, making it available for downloading to a replacement switch, if necessary. For detailed instructions on backing up the configuration, see the HP StorageWorks Fabric OS administrator guide. 8Gb SAN Switch hardware reference manual 45 - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 46
46 Installing and configuring an 8Gb SAN Switch - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 47
54 • Installing Field-Replaceable Units (FRUs), page 56 • Replacing the 8/40 SAN Switch power supply and fan assembly, page 56 • 8/80 fan assembly overview, page 57 • Replacing an 8/80 SAN Switch power supply, page 60 • SAN Switch management features, page 62 Powering the 8/8 or 8/24 SAN Switch on - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 48
possible LED states: • No light • Steady light • Flashing light LED colors include: • Green • Amber 8/8 and 8/24 SAN Switch LEDs 8/8 and 8/24 SAN Switch LEDs are located on the port side only. 6 1 5 2 3 4 1 System power LED (green) 2 System status LED (green/amber) 3 Link status LED 26450a - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 49
Ethernet port status LEDs (green/amber) 3 FC port status (port 9) Figure 20 Identifying 8/40 SAN Switch port side LEDs 1 2 26455a 1 Power supply 1 status LED 2 Power supply 2 status LED Figure 21 Identifying 8/40 SAN Switch nonport side LEDs 26452a 8Gb SAN Switch hardware reference manual 49 - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 50
4 Console port 5 Ethernet port 6 Ethernet speed LED 7 Ethernet link LED 8 FC port status LED (port 0) 9 FC port status LED (port 4) 10 FC ports (0 through 7) 11 FC port status LED (port 48) 12 FC port status LED (port 52) 13 FC ports (53 through 55) Figure 22 Identifying 8/80 SAN Switch port side - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 51
Identifying 8/80 SAN Switch nonport side LEDs Port side LED activity for the 8/80 SAN Switch Table 10 describe LEDs and recommended actions. Table 10 8Gb SAN Switch port side LED on the console. 4. If this does not work, contact your service provider. 8Gb SAN Switch hardware reference manual 51 - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 52
the portEnable command. Port is faulty. Check the management interface and the error log for details on the cause of status. Contact your switch service provider. Port is receiving light or signal carrier at 4 Gbps, but is not yet online. No action required. 52 Operating the 8Gb SAN Switch - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 53
side LED activity for the 8/80 SAN Switch Table 11 describes LEDs and enabled the user. (use the fanEnable command). NOTE: • When the switch is first powered on, the fan status LED will show amber until POST has completed. Replace the fan FRU. 8Gb SAN Switch hardware reference manual - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 54
the 8/40 and 8/80 SAN Switches, described in the following sections. Installing an SFP The 8Gb SAN Switch supports only HP-branded SFPs. See "Supported SFP transceiver options" on page 21, for ordering information. If you use an unqualified SFP, the switchShow command output will show the port in an - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 55
26462a Figure 24 Installing an SFP in the upper row of port slot Diagnostic Tests In addition to POST, Fabric OS includes diagnostic tests to help you troubleshoot the hardware about specific diagnostic tests, see the Fabric OS command reference manual. 8Gb SAN Switch hardware reference manual 55 - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 56
section lists FRUs and provides installation procedures. 8/8 SAN Switch and 8/24 SAN Switch FRU units No components in the 8/8 SAN Switch and 8/24 SAN Switch are field replaceable. If the switch becomes inoperable, replace the entire switch. 8/40 SAN Switch and 8/80 SAN Switch FRU units Replace the - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 57
assembly #3 4 Fan assembly #2 5. Fan assembly #1 Figure 25 8/80 SAN Switch fan assemblies on the nonport side CAUTION: Disassembling any part of the fan assembly voids the part warranty and regulatory certifications. There are no user-serviceable parts inside the fan assembly. Because the cooling - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 58
(s) in the fan assembly has failed. nl The fan FRU was disabled by the user. Verify that the fan FRU is enabled. If the fan FRU is enabled and the FRU is faulty it should be replaced. Replacing the 8/80 SAN Switch fan assembly Replacing a fan assembly takes approximately two minutes. You will need - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 59
it is firmly in. CAUTION: Do not force the installation. If the fan assembly does not slide in easily, ensure 80 SAN Switch 2 Fan assembly unit 3 Captive screw 4 Status LED 5. Handle 6. Nonport side Figure 26 Inserting the fan assembly in the 8/80 SAN Switch 8Gb SAN Switch hardware reference manual - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 60
to provide redundancy. Replacing a power supply takes approximately two minutes. You will need: • 8/80 SAN Switch • New power supply • Phillips-head screwdriver #1 To replace a power supply: 1. If the switch will remain powered on, verify that the functioning power supply (the one not being replaced - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 61
27 Installing a power supply in the 8/80 SAN Switch switch to turn it on. 10. Verify that the LED on the new power supply displays a steady green light while the switch is operating. If the LED is not green, make sure that the power supply is firmly seated. 8Gb SAN Switch hardware reference manual - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 62
monitor fabric topology, check port status, and debug the switch. Table 13 lists the management tools available. When running IP over FC, these management tools must be supported by both HBA and HBA drivers. For a list of supported HBAs, see the HP StorageWorks SAN design guide: http://www.hp.com - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 63
• Fibre Channel port specifications, page 68 • POST and boot specifications, page 68 • Supported HBAs, page 69 Weight and physical dimensions nl Table 14 lists physical properties for the SAN Switches. Table 14 8Gb SAN Switch physical dimensions Property 8/8 and 8/24 SAN 8/40 SAN Switch Switches - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 64
on the nonport side of the switch. 8/40 and 8/80 SAN Switches-Air flows from the nonport side to the port side. A minimum air flow of 47 cu ft/min (79.8 cu m/hr) available in the immediate vicinity of the switch. 8/8 SAN Switch and 8/24 SAN Switch-A minimum air flow of 24 cubic ft/minute available in - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 65
8/24 SAN Switches: 48 W nominal, 57 W maximum nl 8/40 SAN Switch: 84 W nominal, 91 W maximum nl 8/80 SAN Switch: 260 W nominal, 300 W maximum Input voltage 8/8, 8/24 and 8/40 SAN Switches: 85-264 VAC universal nl 8/80 SAN Switch: 90-264 VAC universal 8Gb SAN Switch hardware reference manual 65 - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 66
and 8/24 SAN Switches: 21.5 amps at 240 VAC cold start nl 8/40 SAN Switch: 15 amps to 35 amps maximum nl 8/80 SAN Switch: Maximum of 15 amps for period of 10-150 mS Data transmission ranges See Table 20 and Table 21 for 8Gb SAN Switch data transmission ranges for the different cable types and port - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 67
to 100 km with an HP Extended Fabrics license 40 km (24.8 miles) 50 150 m (492 ft) N/A N/A 4 Gb/s 62.5 70 m (230 ft) N/A N/A 9 N/A N/A N/A 50 150 m NA NA 8Gb/s 62.5 21 m NA NA 9 NA 10 km NA NOTE: For the 8/80 SAN Switch, up to 500 km at 1Gb is supported when using a long - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 68
an HP Extended Fabrics license 80 km (50 miles) 50 150m (492 ft) NA NA 4Gb/s 62.5 70 m (230 ft) NA NA 9 NA 10 km NA 50 150 m (492 ft) N/A N/A 8Gb/s 62.5 21 m N/A N/A 9 N/A 10 km (6.2 miles) N/A Fibre Channel port specifications The Fibre Channel ports in the 8Gb SAN Switch - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 69
. • Enables normal port operation. Supported HBAs For a list of HBAs that have been tested and are known to work with the SAN switches, refer to the latest version of the HP StorageWorks SAN design reference guide: http://www.hp.com/go/sandesignguide. 8Gb SAN Switch hardware reference manual 69 - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 70
70 Technical Specifications - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 71
with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense. The end user of this product - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 72
are no user-serviceable components inside. HP authorized service technicians to repair the laser device. Certification and classification information This product contains a laser internal to the fiber optic (FO) transceiver for connection to the Fibre Channel communications port device installed in - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 73
European Union regulatory notice BSMI notice 8Gb SAN Switch hardware reference manual 73 - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 74
is a danger of explosion and risk of personal injury if the battery is incorrectly replaced or mistreated. Replacement is to be done by an HP authorized service provider using the HP spare part designated for this product. For more information about battery replacement or proper disposal, contact an - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 75
authorized service provider. NOTE: Route power cords so that they will not be walked on and cannot be pinched by items placed upon or against them. Pay particular attention to the plug, electrical outlet, and the point where the cords exit from the product. 8Gb SAN Switch hardware reference manual - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 76
Electronic Equipment directive English notice Disposal of waste equipment by users in private households in the European Union This symbol on recycling, please contact your local city office, your household waste disposal service, or the shop where you purchased the product. Dutch notice Verwijdering - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 77
recyclage des appareils mis au rebut, veuillez contacter les autorités locales de votre région, les services de collecte des ordures ménagères ou le magasin dans lequel vous avez acheté ce produit oder im Geschäft, in dem Sie das Gerät erworben haben. 8Gb SAN Switch hardware reference manual 77 - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 78
önkormányzattól, az illetékes szemételtakarító vállalattól, illetve a terméket elárusító helyen kaphat. Italian notice Smaltimento delle apparecchiature da parte di privati nel territorio dell'Unione Europea Questo simbolo presente sul prodotto o sulla sua confezione indica che il prodotto non pu - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 79
que reciclam esse tipo de material, entre em contato com o escritório da HP em sua cidade, com o serviço de coleta de lixo ou com a loja em que o produto foi adquirido. Slovakian notice Likvidácia vyradených zariadení v domácnostiach v Európskej únii 8Gb SAN Switch hardware reference manual 79 - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 80
ste izdelek kupili. Spanish notice Eliminación de residuos de equipos eléctricos y electrónicos por parte de usuarios particulares en la Unión Europea Este símbolo en el producto o en su att få mer information om var du kan lämna ditt avfall för återvinning. 80 Regulatory compliance and safety - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 81
This type of damage may reduce the life expectancy of the device. To prevent HP authorized reseller install the part. NOTE: For more information on static electricity, or for assistance with product installation, contact your HP authorized reseller. 8Gb SAN Switch hardware reference manual - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 82
82 Electrostatic discharge - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 83
8Gb SAN Switch, 40 power supply specifications, 65 psshow command, 62 R rack mount considerations, 27 rack stability warning, 11 related documentation, 9 S safety considerations, 27 serial connection, 40 set the IP address, 42 shipping carton contents, 25 8Gb SAN Switch hardware reference manual 83 - HP StorageWorks 8/40 | HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 84
, HP, 11 supported HBAs, 69 supported sfp options, 21 switchshow command, 45 symbols in text, 10 T technical support HP, 11 service locator website, 12 text symbols, 10 W warning rack stability, 11 websites customer self repair, 11 HP , 12 HP Subscriber's Choice for Business, 11 product manuals
HP StorageWorks
8Gb SAN Switch hardware reference manual
5697-7478
Part number: 5697-7478
First edition: June 2008