HP StorageWorks 8/40 HP StorageWorks Fabric OS 6.1.1d release notes (5697-7962
HP StorageWorks 8/40 - SAN Switch Manual
View all HP StorageWorks 8/40 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks 8/40 manual content summary:
- HP StorageWorks 8/40 | HP StorageWorks Fabric OS 6.1.1d release notes (5697-7962 - Page 1
HP StorageWorks Fabric OS 6.1.1d release notes Part number: 5697-7962 Fourth edition: January 2009 - HP StorageWorks 8/40 | HP StorageWorks Fabric OS 6.1.1d release notes (5697-7962 - Page 2
Legal and notice information © Copyright 2008-2009 Hewlett-Packard Development Company, L.P. © Copyright 2008-2009 Brocade Communications Sylemstems, Incorporated - HP StorageWorks 8/40 | HP StorageWorks Fabric OS 6.1.1d release notes (5697-7962 - Page 3
providing FCR support on 8-Gb ports and blades • Fibre Channel over IP protocol (FCIP) • Traffic Isolation Zones over FCR • Port Mirroring on 8-Gb platforms • Buffer credit recovery on all 8-Gb platforms • FCIP performance enhancements • Port Fencing support in Fabric Watch HP StorageWorks Fabric OS - HP StorageWorks 8/40 | HP StorageWorks Fabric OS 6.1.1d release notes (5697-7962 - Page 4
Access Gateway to an adjacent switch. The adjacent switch to the Access Gateway must be an HP StorageWorks switch running Fabric OS 6.1.x or later. This feature also enhances availability by enabling seamless failover of traffic from a failed N_Port to other ports in a trunk group. Trunking is - HP StorageWorks 8/40 | HP StorageWorks Fabric OS 6.1.1d release notes (5697-7962 - Page 5
or 4/256 SAN Director chassis. Scripting Many automatic page breaks in CLI output for commands have been removed to facilitate scripting. Notification of duplicate WWN entry A RASLOG entry will occur when a switch detects that a duplicate WWN has logged in. HP StorageWorks Fabric OS 6.1.1d - HP StorageWorks 8/40 | HP StorageWorks Fabric OS 6.1.1d release notes (5697-7962 - Page 6
Directors with an MP router blade (FR4-18i). See Firmware upgrade instructions, page 15 for instructions on upgrading to Fabric OS 6.1.1d. New hardware support There is no new hardware support introduced with Fabric OS 6.1.1x. NOTE: The HP StorageWorks SAN Director 16 Port 8-Gb FC blade (FC8-16) is - HP StorageWorks 8/40 | HP StorageWorks Fabric OS 6.1.1d release notes (5697-7962 - Page 7
• HP StorageWorks SAN Director 6 Port 10-Gb FC ISL blade (Brocade FC10-6) Unsupported product models The following product models cannot be upgraded to Fabric OS 6.1.1x or later: • HP StorageWorks Core Switch 2/64 (Brocade 12000) • HP StorageWorks SAN Director 2/128 (Brocade 24000) • HP StorageWorks - HP StorageWorks 8/40 | HP StorageWorks Fabric OS 6.1.1d release notes (5697-7962 - Page 8
24 SAN Switch (Brocade 300) IMPORTANT: Although the HP StorageWorks 4/8 SAN Switch uses the same hardware as the 4/16 SAN Switch, it does not support Access Gateway. The same applies to the HP StorageWorks 8/8 and 8/24 SAN Switches: both use the same hardware, but only the 8/24, which has all ports - HP StorageWorks 8/40 | HP StorageWorks Fabric OS 6.1.1d release notes (5697-7962 - Page 9
modes for deployment with M-EOS-based products. All HP StorageWorks models that are supported by Fabric OS 6.1.1d support both interopmodes 2 and 3, with the exception of the HP StorageWorks 4/32 SAN Switch. Table 1 specifies the support of various Fabric OS features when operating in either - HP StorageWorks 8/40 | HP StorageWorks Fabric OS 6.1.1d release notes (5697-7962 - Page 10
(frame level) Dynamic Path Selection (DPS, exchange-based routing) Dynamic Load Sharing (DLS, port-based routing) Virtual Channels (VC RDY) FICON Management Server (Cascading) FICON MIHPTO Full scalability (to maximum M-EOS fabric limits) Adaptive Networking: QoS Adaptive Networking: Ingress Rate - HP StorageWorks 8/40 | HP StorageWorks Fabric OS 6.1.1d release notes (5697-7962 - Page 11
. Prerequisites Table 2 lists the supported Fabric OS firmware versions. HP recommends using the latest supported firmware release versions to get the greatest benefit from the SAN. For a list of retired products, see the HP website: http://www.hp.com HP StorageWorks Fabric OS 6.1.1d release notes - HP StorageWorks 8/40 | HP StorageWorks Fabric OS 6.1.1d release notes (5697-7962 - Page 12
supported by HP at the time of the Fabric OS 6.1.1d release. Table 2 Supported Fabric OS versions Model HP StorageWorks 1-Gb Switch HP StorageWorks SAN Switch 2/8 EL HP StorageWorks SAN Switch 2/16 MSA SAN Switch 2/8 Earliest compatible ver- Recommended version sion Not supported, end of support - HP StorageWorks 8/40 | HP StorageWorks Fabric OS 6.1.1d release notes (5697-7962 - Page 13
(FC8-32) 6.1.1d HP StorageWorks SAN Director 48 Port 8-Gb FC 6.0.0b blade (FC8-48) 6.1.1d HP StorageWorks SAN Director 6 Port 10-Gbb ISL blade (FC10-6) 6.0.0b 6.1.1d Fabric Manager 5.2.0a 5.5 Data Center Fabric Manager 10.0.2 10.1.0 4/256 SAN Director blade support Fabric OS 6.1.1d is - HP StorageWorks 8/40 | HP StorageWorks Fabric OS 6.1.1d release notes (5697-7962 - Page 14
operate with nominal power of 110 VAC. See the appropriate hardware reference guide for power specifications. Fibre Channel Routing scalability For the latest FCR scalability support information, see the HP StorageWorks SAN design reference guide, available at: http://www.hp.com/go/sandesignguide - HP StorageWorks 8/40 | HP StorageWorks Fabric OS 6.1.1d release notes (5697-7962 - Page 15
and then select Cross operating system (BIOS, firmware, Diagnositcs, etc.) 3. Select Firmware (HP StorageWorks Fabric OS release notes 13). 4. Select V6.x Firmware for HP StorageWorks B-Series Fibre Channel Switches for 6.1.1d: • To download the firmware, select Download. • To read the release notes - HP StorageWorks 8/40 | HP StorageWorks Fabric OS 6.1.1d release notes (5697-7962 - Page 16
48-port blade. To allow hot code load on an HP 8/40 SAN Switch when using Integated Routing, the edge switch connected to the HP 8/40 SAN Switch must be running Fabric OS 6.1 or later. The HP 8/40 SAN Switch does not support Hot Code Load from FOS 6.1.0 to 6.1.1 in a dual backbone configuration with - HP StorageWorks 8/40 | HP StorageWorks Fabric OS 6.1.1d release notes (5697-7962 - Page 17
performance and scalability (24 physical fabrics, up to 9,000 switch ports). DCFM Enterprise configures and manges DCX backbones, along with HP StorageWorks directors, routers, and switches. Existing EFCM and FM customers that have active Maintenance and Support contracts are provied a seamless - HP StorageWorks 8/40 | HP StorageWorks Fabric OS 6.1.1d release notes (5697-7962 - Page 18
the disable option; otherwise, the link will continuously reset. The Adaptive Networking SID/DID Traffic Prioritization QoS feature is not supported on Extended Fabrics E_ports when IDLE primitives are configured on these ports. This is because in this mode only data Virtual Channels are available - HP StorageWorks 8/40 | HP StorageWorks Fabric OS 6.1.1d release notes (5697-7962 - Page 19
• Provides additional information on a faulty port in Fabric Watch to aid in troubleshooting. • Enables use of passive FTP to download firmware. • Enables the user to specify a quality password policy that prevents the selection of passwords with consecutive, identical characters. • Uses multiple - HP StorageWorks 8/40 | HP StorageWorks Fabric OS 6.1.1d release notes (5697-7962 - Page 20
Web Tools 6.1.0 DCFM Reports > Fabric summary Monitor > Reports > Fabric Summary report Comments FCIP tunnel configuration Port Admin Module > GigE tab Configure > FCIP tunnel GigE ports interface GigE ports route Non-local switch ports display in zoning tree Port Admin Module > GigE tab - HP StorageWorks 8/40 | HP StorageWorks Fabric OS 6.1.1d release notes (5697-7962 - Page 21
loss of buffer credit. Mixed fabric of McDATA and Brocade switches cannot be managed Fixed in Fabric OS 6.1.1. if only IPv6 addressing is supported. HBA is not following Fibre Channel protocol standards, which could Fixed in Fabric OS 6.1.1. cause a switch reboot. Problems in an IP network could - HP StorageWorks 8/40 | HP StorageWorks Fabric OS 6.1.1d release notes (5697-7962 - Page 22
the device on the other end of the link. Fixed in Fabric OS 6.1.1a. After systemverification -short is completed on the HP 8/80 Fixed in Fabric OS 6.1.1a. SAN Switch, the route is affected on platforms with BI ports. Third-party application paths fail with FC Fast Write enabled with bid- Fixed in - HP StorageWorks 8/40 | HP StorageWorks Fabric OS 6.1.1d release notes (5697-7962 - Page 23
hareboot. Fixed in Fabric OS 6.1.1b. HP 4/32B SAN Switch experienced an out-of-memory condition oper- Fixed in Fabric OS 6.1.1b ating in a fabric with an McDATA 2640 SAN router. CRC errors were seen on trunk ports between an HP 8/40 and 8/80 Fixed in Fabric OS 6.1.1b switch with a particular SFP - HP StorageWorks 8/40 | HP StorageWorks Fabric OS 6.1.1d release notes (5697-7962 - Page 24
portdisable/enable on HP Stor- Fixed in Fabric OS 6.1.1d. ageWorks SAN Director 48 Port FC blade. Switch may experience timeouts and traffic interruption during HCL operation of neighboring switch with FOS v6.2.0. Fixed in Fabric OS 6.1.1d. Observed kernel panic on HP StorageWorks DC SAN Director
HP StorageWorks Fabric OS 6.1.1d
release notes
Part number: 5697-7962
Fourth edition: January 2009