- HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 1
HP StorageWorks 8-Gb SAN Switch hardware reference manual Part number: 5697-8047 Third edition: June 2009 - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 2
2009 Brocade Communications Systems, Incorporated Confidential computer software. Valid license from HP HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 3
15 HP StorageWorks 8-Gb SAN Switch models 16 Power Pack+ models ...17 8/8 and 8/24 SAN Switch features 17 Port side of the 8/8 and 8/24 SAN Switch 17 Nonport side of the 8/8 and 8/24 SAN Switch 18 Activating additional 8/8 and 8/24 SAN Switch ports 18 Enabling E_Ports on the 8/8 SAN Switch 18 - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 4
the HP SAN Switch Rack Mount Kit in your HP custom rack 36 Installing the plenum (if required 44 Securing the switch to the outer rails 44 Cabling and configuring the SAN Switch 45 Connecting the SAN Switch to the fabric 46 EZSwitch Setup (optional) ...46 Obtain required items ...46 Powering on - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 5
Replacing the 8/80 SAN Switch and Encryption SAN Switch fan assembly 74 Replacing an 8/80 SAN Switch or Encryption SAN Switch power supply 76 Power supply ...78 SAN Switch management features 78 4 Encryption SAN Switch specifications 81 5 Technical Specifications 83 Weight and physical - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 6
Italian notice ...100 Latvian notice ...101 Lithuanian notice ...101 Polish notice ...101 Portuguese notice ...102 Slovakian notice ...102 Slovenian notice ...102 Spanish notice ...102 Swedish notice ...103 B Electrostatic discharge 105 How to prevent electrostatic discharge 105 Grounding methods - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 7
device in an HP System/e Rack 45 21 Connecting the serial cable 47 22 Encryption configuration 56 23 Identifying 8/8 and 8/24 SAN Switch LEDs 57 24 Identifying 8/40 SAN Switch port side LEDs 58 25 Identifying 8/40 SAN Switch nonport side LEDs 58 26 Identifying 8/80 SAN Switch port side LEDs - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 8
33 Inserting the fan assembly in the 8/80 SAN Switch 76 34 Installing a power supply in the 8/80 or Encryption SAN Switch 77 35 Class 1 laser product label 94 8 - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 9
83 20 8/8, 8/24 and 8/40 SAN Switch memory 84 21 8/80 SAN Switch, Encryption SAN Switch, and FCoE Converged Network Switch memory ...84 22 Facility requirements 84 23 EMC compatibility 85 24 Power supply specifications 86 25 Laser data transmission ranges for the 8/8 and 8/24 SAN Switches 87 26 - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 10
10 - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 11
This installation guide provides information to help you set up and configure the following HP switches: • HP StorageWorks 8/8 SAN Switch • HP StorageWorks 8/24 SAN Switch • HP StorageWorks 8/40 SAN Switch • HP StorageWorks 8/80 SAN Switch • HP StorageWorks Encryption SAN Switch • HP StorageWorks - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 12
conventions Convention Blue text: Table 1 Blue, underlined text: http://www.hp.com Bold text Element Cross-reference links and email addresses Website addresses data. IMPORTANT: Provides clarifying information or specific instructions. NOTE: Provides additional information. Rack stability Rack - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 13
service HP recommends that you register your product at the Subscriber's Choice for Business website: http://www.hp.com/go/e-updates After registering, you will receive email notification of product enhancements, new driver versions, firmware updates, and other product resources. 8-Gb SAN Switch - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 14
http://www.hp.com/support/manuals • http://www.hp.com/support/downloads Documentation feedback HP welcomes your feedback. To make comments and suggestions about product documentation, please send a message to [email protected]. All submissions become the property of HP. 14 About this guide - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 15
15 • HP StorageWorks 8Gb SAN Switch models, page 16 • Power Pack+ models, page 17 • 8/8 and 8/24 SAN Switch features, page 17 • 8/40 SAN Switch features, page 18 • 8/80 SAN Switch features, page 20 • Port side of the Encryption SAN Switch, page 23 • Installing and activating Port Upgrade licenses - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 16
8/40 SAN Switch-Ships with 24 ports activated and includes a Full Fabric license. It includes Advanced Web Tools, Advanced Zoning, and Enhanced Group Manager (EGM) as standard software components. • HP StorageWorks 8/40 Power Pack+ SAN Switch-Ships with 24 ports activated and includes a Full Fabric - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 17
see the HP StorageWorks Fabric OS administrator guide for the firmware version you are running. 8/8 and 8/24 SAN Switch features • Functions as an edge device in fabrics of up to 239 switches. • Integrates a single motherboard design with 667 MHz PowerPC 440EPx Reduced Instruction Set Computer (RISC - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 18
activating Port Upgrade licenses, page 26. Enabling E_Ports on the 8/8 SAN Switch The 8/8 SAN Switch model requires that you purchase the HP StorageWorks Full Fabric Upgrade License, part number T4261A, to enable E_Ports (the 8/24 SAN Switch ships with the Full Fabric license installed). By default - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 19
remote fabric isolation. See Table 6, page 29 for ordering information. • Integrates a Universal Serial Bus (USB) port that provides storage for firmware updates, output of the supportsave command and storage for configuration uploads and downloads. Port side of the 8/40 SAN Switch The port side - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 20
and install one upgrade license. • To enable ports 32 through 40, you must purchase and install a second upgrade license. See Installing and activating Port Upgrade licenses, page 26. 8/80 SAN Switch features • Provides the EZSwitch Setup Wizard for easy setup and basic configuration. • Integrates - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 21
the 8/80 SAN Switch. 1 8/80 SAN Switch 2 Switch ID pull-out tab 3 Status LED (top) power LED (bottom) 4 Console port 5 Ethernet port 6 USB port 7 FC ports 0-7 8 FC ports 8-15 9 FC ports 16-23 10 FC ports 24-31 11 FC ports 32-38 12 FC ports 40-47 13 FC ports 48-55 14 FC ports 56-63 15 FC ports 64 - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 22
Fan assembly #1 7 Power supply #1 Activating additional 8/80 SAN Switch ports By default, the 8/80 SAN Switch model integrates 48 licensed ports (ports 0 through 47). To enable additional ports, you must purchase and install the HP StorageWorks 8/80 SAN Switch 8-Gb 16-port Upgrade LTU (part number - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 23
• Hardware-based key management and generation • Integrated Routing Fabric Service (optional) to enable encryption capabilities across multiple fabrics • NPIV support • Two hot-swappable, redundant power supply field-replaceable units (FRUs) • Three hot-swappable fan FRUs in the N+1 configuration to - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 24
• Contains 24 ports, 10-GbE CEE. • Provides Low-latency, lossless, deterministic interconnect required for FCoE. • Provides FCoE support with Fabric Provided MAC Address (FPMA) discovery. Fabric OS also enables support for Priority-based Flow Control (802.1Qbb). 24 HP StorageWorks 8-Gb SAN Switches - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 25
-GbE ports 16-23 4. Management Ethernet port 9. FC ports 0-7 5. USB port Figure 7 Port side of the FCoE Converged Network Switch Nonport side of the FCoE Converged Network Switch Figure 8 shows the nonport side of the FCoE Converged Network Switch. 8-Gb SAN Switch hardware reference manual 25 - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 26
Converged Network Switch Installing and activating Port Upgrade licenses 1. Use the portshow command to verify the number of ports licensed on your switch. The port status output indicates Started and Licensed for enabled ports. See the Fabric OS Command Reference Manual for specific information - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 27
0 through 7 2. Trunk group 2: Ports 8 through 15 3. Trunk group 3: Ports 16 though 23 Figure 9 Trunking groups example For more information about trunking, see the HP StorageWorks Fabric OS administrator guide for the firmware version you are running. 8-Gb SAN Switch hardware reference manual 27 - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 28
Table 5 list the only SFPs supported in your HP StorageWorks 8-Gb SAN Switches. Table 2 FCoE Converged Network Switch long range and short range 10-Gb CEE and cable options Option HP 10-GbE SR B-series SFP+ Transceiver HP 10-GbE LR B-series SFP+ Transceiver HP 1m B-series Active Copper SFP+ Cable - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 29
kits Option Part number HP StorageWorks Full Fabric Upgrade License T4261A HP StorageWorks 8/8 and 8/24 SAN Switch 8-Gb 8-port Upgrade LTU T5518A HP StorageWorks 8/80 SAN Switch 8-Gb 16-port Upgrade LTU T5520A HP StorageWorks 8/40 SAN Switch 8-Gb 8-port Upgrade LTU T5519A Adaptive - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 30
221691-B23 221691-B26 221691-B27 NOTE: To obtain the latest information on hardware and software components, go to the B-Series section of the following HP website: http://www.hp.com/go/san. 30 HP StorageWorks 8-Gb SAN Switches - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 31
33 • Items required for installation, page 34 • Installing the switch as a stand-alone device, page 35 • Installing the switch using the SAN Switch Rack Mount Kit, page 35 • Cabling and configuring the SAN Switch, page 45 • Connecting the SAN Switch to the fabric, page 46 Shipping carton contents - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 32
, containing the following items: • One set of HP StorageWorks product documentation, including HP Storage- Works 8-Gb SAN Switch quick start instructions, HP StorageWorks SAN Switch Rack Mount Kit installation instructions, Read Me First, Safety Guides, User License, and Warranty • One serial cable - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 33
and HP 10000 Series Rack See "Installing the switch using the SAN Switch Rack Mount Kit" on page 35 for detailed instructions. Electrical considerations For successful installation and operation of the switch, ensure that the following electrical requirements are met. See Power supply specifications - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 34
Converged Network Switches, both HP-branded FC SFPs and CEE 10-GbE SFPs are required. FC SFP+ transceivers are required for 8-Gb/s performance; copper cables must be HP-branded. • Access to an FTP server to back up the switch configuration (optional) 34 Installing and configuring an 8-Gb SAN Switch - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 35
the network until the IP address is set. See "Set the IP address" on page 48. Installing the switch using the SAN Switch Rack Mount Kit The SAN Switch Rack Mount Kit is supplied with your 8-Gb SAN Switch. Use the SAN Switch Rack Mount Kit with the following optional HP StorageWorks custom racks only - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 36
of the rack. In this installation, the port side of the switch is set 12.7 cm (5 inches) back from the edge of the rack, allowing a more gradual bend in the fiber optic cables. NOTE: The SAN Switch Rack Mount Kit installation requires one technician. 36 Installing and configuring an 8-Gb SAN Switch - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 37
The following items are required to install the switch in a rack: • SAN Switch • Power cables • #2 Phillips screwdriver • 7/16-inch wrench or socket • Plenum (if required). For 8-Gb models, a plenum is required for 8/8 and 8/24 SAN Switches only. • SAN Switch Rack Mount Kit hardware, shown in Table - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 38
. This mounting allows air to enter the front of the rack and exhaust at the rear. To install the device in a rack: 1. Verify that the required parts and hardware are available. See Table 9. 2. Choose a mounting location for the device in the rack. 38 Installing and configuring an 8-Gb SAN Switch - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 39
11 Installing the rear mounting brackets (HP 10000 series racks) Figure 12 Installing the rear mounting brackets (HP System/e Rack) NOTE: Your SAN Switch Rack Mount Kit contains both right rails and left rails. The rails are labelled Right and Left. 8-Gb SAN Switch hardware reference manual 39 - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 40
Then install two #10-32 x 1/2-inch Phillips pan-head screws with captive star lock-washers and two #10 adapter washers in the upper and lower hole locations of the left rail. See Figure 14. Figure 14 Assembling the outer rails (HP 10000 series racks) 40 Installing and configuring an 8-Gb SAN Switch - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 41
rails to the switch Device model 8/8 SAN Switch 8/24 SAN Switch 8/40 SAN Switch 8/80 SAN Switch #8-32 x 5/16-inch #8-32 x 3/16-inch screws screws Ten (five per rail) N/A Encryption SAN Switch FCoE Converged Network Switch Six (three per rail) N/A 8-Gb SAN Switch hardware reference manual 41 - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 42
to the 8/40 or 8/80 SAN Switches, use the screw holes marked 16, as shown in Figure 17 on page 43. c. To attach the inner rails to the FCoE Converged Network Switch, or Encryption SAN Switch, use two screw holes marked R and one screw hole marked 16. 42 Installing and configuring an 8-Gb SAN Switch - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 43
8/24, 8/40, and 8/80 SAN Switches. Figure 16 Securing the inner rails to an MP Router Figure 17 Securing the inner rails to the 4/64 SAN Switch NOTE: For factory integration only, tighten the #8-32 x 5/16-inch Phillips pan-head SEMS screws and torque between 6 and 8 inch-pounds. 8. If installing - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 44
the plenum faces the rear of the device. When installed properly, you should see the plenum's air vent holes on one side, and the front panel of the device on the other. Securing the switch to the outer rails To secure the switch to the outer rails: 44 Installing and configuring an 8-Gb SAN Switch - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 45
Switch The SAN Switch must be configured to ensure correct operation with a network and fabric. For instructions on configuring the switch to operate in a fabric containing switches from other vendors, see the HP StorageWorks Fabric OS administrator guide. 8-Gb SAN Switch hardware reference manual - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 46
8/40 and 8/80 SAN Switches, Encryption SAN Switch, and FCoE Converged Network Switch use two power cords. IMPORTANT: The 8/8 and 8/24 SAN Switches do not have an on/off switch. Power is supplied as soon as you connect it to an AC power source. To power on the switch: 46 Installing and configuring - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 47
AC failure on the 8/40 and 8/80 SAN Switches, Encryption SAN Switch, and FCoE Converged Network Switch, connect each power cord to outlets on separate circuits. 2. For the 8/40 and 8/80 SAN Switches, Encryption SAN Switch, and FCoE Converged Network Switch, set the two AC switches to the ON position - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 48
the prompt: tip /dev/ttya -9600 Setting the switch IP address You can configure the 8-Gb SAN Switch with a static IP address, or you can use a Dynamic Host Configuration Protocol (DHCP) server to set the IP address. DHCP is enabled by default. The 8-Gb SAN Switch supports both IPv4 and IPv6. DHCP - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 49
for the Encryption SAN Switch). Setting the domain ID To set the switch domain ID: 1. Log on to the switch using Telnet, using the admin account. 2. Modify the domain ID, if required. The default domain ID is 1. • If the switch is not powered on until after it is connected to the fabric and the - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 50
time zone (0,0). If all switches in a fabric are in one time zone, it is possible for you to keep the time zone setup at the default setting. • System services that have already started will reflect the time zone changes only after the next reboot. 50 Installing and configuring an 8-Gb SAN Switch - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 51
. For more information on using an NTP server, and IPv6 considerations, see the HP StorageWorks Fabric OS 6.1.x administrator guide and the HP StorageWorks Fabric OS 6.2.x administrator guide. 1. Log in to the switch using the default password: password. 8-Gb SAN Switch hardware reference manual 51 - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 52
about the fabric. Backing up the configuration HP recommends regular backups to ensure that a recent configuration is available. To back up the switch configuration to an FTP server: 1. Issue the configupload command. 2. Follow the prompts. 52 Installing and configuring an 8-Gb SAN Switch - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 53
The command uploads the switch configuration to the server, making it available for downloading to a replacement switch, if necessary. For detailed instructions on backing up the configuration, see the HP StorageWorks Fabric OS administrator guide. 8-Gb SAN Switch hardware reference manual 53 - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 54
54 Installing and configuring an 8-Gb SAN Switch - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 55
the HP StorageWorks 8/40 and 8/80 SAN Switches, the Encryption SAN Switch and the FCoE Converged Network Switch. This chapter describes the following topics: • Configuring the Encryption SAN Switch, page 55 • Interpreting LED activity, page 56 • Port side LED activity for the 8/80 SAN Switch, page - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 56
Figure 22 Encryption configuration Configuring the FCoE Converged Network Switch See the Brocade Converged Enhanced Ethernet Administrator's Guide for details on configuring the CEE portion of the FCoE Converged Network Switch. 8-Gb SAN Switch LEDs System activity and status can be determined - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 57
status LED 4 Link speed LED 5 Port status LED (port 3) 6 Port status LED (port 7) Figure 23 Identifying 8/8 and 8/24 SAN Switch LEDs 8/40 SAN Switch LEDs 8/40 SAN Switch LEDs are located on the port side and nonport side. See Figure 24 and Figure 25. 8-Gb SAN Switch hardware reference manual 57 - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 58
LEDs (green/amber) 3 FC port status (port 9) Figure 24 Identifying 8/40 SAN Switch port side LEDs 1 Power supply 1 status LED 2 Power supply 2 status LED Figure 25 Identifying 8/40 SAN Switch nonport side LEDs 8/80 SAN Switch LEDs 8/80 SAN Switch LEDs are located on the port side and nonport side - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 59
LED 6 FC port status LED (port 0) 7 FC port status LED (port 4) 8 FC ports (0 through 7) 9 FC ports (48 through 55) 10 FC port status LED (port 52) 11 FC port status LED (port 48) 12 Console port 13 System power LED Figure 26 Identifying 8/80 SAN Switch port side LEDs 8-Gb SAN Switch hardware - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 60
LED Figure 27 Identifying 8/80 SAN Switch nonport side LEDs Port side LED activity for the 8/80 SAN Switch Table 11 describes LEDs and recommended actions. Table 11 8-Gb SAN Switch port side LED patterns LED name LED color Status of hardware Recommended action Power status No light Steady - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 61
running. Re-enable the port using the portEnable command. Fast flashing amber (flashing in halfsecond intervals) Port is faulty. Check the management interface and the error log for details on the cause of status. Contact your switch service provider. 8-Gb SAN Switch hardware reference manual 61 - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 62
has failed. • The fan FRU was disabled by the user. NOTE: When the switch is first powered on, the fan status LED will show amber until POST has completed. Try the following: • Verify the fan FRU is enabled (use the fanEnable command). • Replace the fan FRU. 62 Managing the 8-Gb SAN Switches - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 63
: • Verify the power LED is on; check the SFP and cable. • Verify the switch is initializing. • Verify the status of the connected device. Steady green Port is online (connected to external device), but there is no traffic. No action required. 8-Gb SAN Switch hardware reference manual 63 - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 64
not running. Re-enable the port us- command. ing the portEnable command. Fast flashing amber (on 1/2 second, SFP or port is faulty. then off 1/2 second) Replace the SFP. Reset the port. No light Indicates one of the following: • Power supply FRU is switched off. • Power supply FRU is not - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 65
disabled by the user. NOTE: When the switch is first powered on, the port status LED (port 0) 6. CEE port status LED (port 4) Figure 28 Port side LEDs on the FCoE Converged Network Switch Table 14 describes the port side LEDs and the recommended actions. 8-Gb SAN Switch hardware reference manual - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 66
can cause this status, including a power supply failure, fan failure, or if one or more environmental ranges have been exceeded. Check the management interface and the error log for details on the cause of the status. Contact your switch service provider. Port speed is 10 Mb/s. No action - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 67
diagnostic tests are not running. Re-enable the port using the portEnable command. Fast blinking amber (1/2 second) Port failure Check the management interface and the error log for details on the cause of the failure. Contact HP technical support if necessary. Steady green Online No action - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 68
fan FRU. Interpreting POST results POST is a system check that is performed each time the switch is powered on, rebooted, or reset, and during which the LEDs flash different colors. To determine if POST completed successfully and whether any errors were detected: 68 Managing the 8-Gb SAN Switches - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 69
sections. Installing an SFP The 8-Gb SAN Switches support only HP-branded SFPs. nl See "Supported SFP transceiver options" on page 28, for ordering information. If you use an unqualified SFP, the switchShow command output will show the port in an Mod_Inv state. Additionally, the firmware will also - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 70
tests, see the Brocade Fabric OS Troubleshooting and Diagnostics Guide. Installing Field-Replaceable Units This section lists FRUs and provides FRU installation procedures. 8/8 SAN Switch and 8/24 SAN Switch FRU units No components in the 8/8 SAN Switch and 8/24 SAN Switch are field replaceable - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 71
8/40 SAN and FCoE Converged Network Switch FRU units Replace the power supply and fan assembly unit. Verifying one at a time. They are identical and fit into any fan slot. Fabric OS identifies the fan assemblies as follows (viewing the switch from the nonport side): • Fan assembly 2 is on the left. - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 72
FRU is enabled and the FRU is faulty it should be replaced. Replacing the 8/40 SAN Switch power supply and fan assembly CAUTION: Disassembling any part of the power supply and fan assembly voids the warranty and regulatory certifications. There are no user-serviceable parts inside the power supply - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 73
using the fanShow command from the CLI. 8/80 SAN Switch and Encryption SAN Switch FRU units Replace the following FRUs as required: • Fan assembly • Power supply The 8/80 SAN Switch and Encryption SAN Switch integrate three fan assemblies (see Figure 32). Fabric OS identifies the fans from left to - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 74
Fan assembly #2 5. Fan assembly #3 Figure 32 8/80 and Encryption SAN Switch fan assemblies on the nonport side CAUTION: Disassembling any part of the fan assembly voids the part warranty and regulatory certifications. There are no user-serviceable parts inside the fan assembly. Because the cooling - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 75
CAUTION: The 8/80 and Encryption SAN Switches use two power cords. Disconnect both power cords before servicing. To replace a fan assembly assembly into the chassis until it is firmly in. CAUTION: Do not force the installation. If the fan assembly does not slide in easily, ensure that it is correctly - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 76
33 Inserting the fan assembly in the 8/80 SAN Switch Replacing an 8/80 SAN Switch or Encryption SAN Switch power supply CAUTION: If a power supply fails, leave the power supply in the switch until it can be replaced. Maintain both power supplies in operational condition to provide redundancy - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 77
powered off, press the AC power switch to power it off. 3. Unplug the power cord from the power supply you are replacing. 1. AC power receptacle 3. Handle 5. AC power switch 2. Status LED 4. Captive screw 6. Power supply Figure 34 Installing a power supply in the 8/80 or Encryption SAN Switch - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 78
monitor fabric topology, check port status, and debug the switch. Table 17 lists the management tools available. When running IP over FC, these management tools must be supported by both HBA and HBA drivers. For a list of supported HBAs, see the HP StorageWorks SAN design guide: http://www.hp.com - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 79
(over HBA only Data Center Fabric Manager (optional)-For information, see the Brocade Data Center Fabric Manager Enterprise User guide or the Brocade Data Center Fabric Manager Professional User guide. Ethernet or serial connection IP over FC 8-Gb SAN Switch hardware reference manual 79 - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 80
80 Managing the 8-Gb SAN Switches - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 81
2 (nonencrypted traffic), Class 3, Class F (inter-switch frames) Fabric switches supporting unicast, multicast (255 groups), and broadcast One USB port for system uploads and downloads, and firmware upgrades (supportsame, configUploads, configDownloads) 8-Gb SAN Switch hardware reference manual 81 - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 82
State Change Notification (RSCN), NTP v3, Reliable Commit Service (RCS), Dynamic Path Selection (DPS), Brocade Advance Zoning (default zoning), Port/WWN zoning, broadcast zoning, NPIV, FDML, Management Server, FSPF, Fabric Watch, Extended Fabrics, ISL, Trunking, Advanced Performance Monitor (APM - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 83
90 • Supported HBAs, page 91 Weight and physical dimensions Table 19 lists physical properties for the SAN Switches. Table 19 8-Gb SAN Switch physical dimensions Property Height 8/8 and 8/24 SAN Switches 4.29 cm(1.69 in) 8/40 SAN Switch 8/80 SAN Switch Encryption SAN Switch FCoE Converged - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 84
8/24 and 8/40 SAN Switch memory Memory type Main Memory (SDRAM) Boot Flash Compact Flash Install memory 512 MB 8/40 SAN Switch only: 4 MB 1 GB Table 21 lists 8/80 SAN Switch, Encryption SAN Switch, and FCoE Converged Network Switch memory specifications. Table 21 8/80 SAN Switch, Encryption SAN - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 85
8/24, and 8/40 SAN Switches and FCoE Converged Network Switch-One rack unit in a 48.3 cm (19 in) cabinet. 8/80 and Encryption SAN Switches- power supply integrates its own built-in fan for cooling, pushing the air forward toward the port side of the switch. 8-Gb SAN Switch hardware reference manual - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 86
supply); in-rush current: less than 60 A peak System power consumption Input voltage 8/8 and 8/24 SAN Switches: 48 W nominal, 57 W maximum 8/40 SAN Switch: 84 W nominal, 91 W maximum 8/80 SAN Switch: 260 W nominal, 300 W maximum Encryption SAN Switch: 100-240 VAC, universal FCoE Converged Network - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 87
40 SAN Switch, up to 500 km at 1 Gb is supported when using a long distance transport system such as DWDM. Table 26 Laser data transmission ranges for the 8/40 SAN Switch Port km (6.2 miles) Extended long wavelength N/A N/A 40 km (24.8 miles) N/A N/A 8-Gb SAN Switch hardware reference manual 87 - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 88
an HP Extended Fabrics license 40 km (24.8 miles) N/A N/A N/A N/A N/A 10 km N/A N/A N/A N/A N/A N/A NOTE: For the 8/80 SAN Switch, up to 500 km at 1 Gb is supported when using a long distance transport system such as DWDM. Table 27 Laser data transmission ranges for the 8/80 SAN Switch Port - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 89
Table 28 Laser data transmission ranges for the Encryption SAN Switch and the FCoE Converged Network Switch Port speed 1 Gb/s 2 Gb/s Cable size ( ) NOTE: Up to 500 km at 1 Gb/s is supported when using a long distance transport system such as DWDM. 8-Gb SAN Switch hardware reference manual 89 - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 90
meet all required safety standards. The ports are capable of operating at 1, 2, 4, or 8 Gb/s and are able to autonegotiate to the maximum link speed. POST and boot specifications The switch performs POST by default each time it is powered on or rebooted or the system is reset. Boot time with POST is - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 91
. • Enables normal port operation. Supported HBAs and CNAs NOTE: Converged Network Adapters (CNAs) apply to the FCoE Converged Network Switch only. For a list of HBAs that have been tested and are known to work with the SAN switches, refer to the latest version of the HP StorageWorks SAN design - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 92
92 Technical Specifications - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 93
installed and used in accordance with the instruction manual Company may void the user's authority to operate the . Laser device All HP systems equipped with a set by government agencies as a Class 1 laser product. The product does not emit hazardous light. 8-Gb SAN Switch hardware reference manual - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 94
. There are no user-serviceable components inside. • Do HP authorized service port. In the USA, the FO transceiver is certified as a Class 1 laser product conforming to the requirements contained in the Department of Health and Human Services on the surface of the HP supplied laser device. Figure 35 - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 95
numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. European Union regulatory notice BSMI notice 8-Gb SAN Switch hardware reference manual 95 - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 96
Your switch is equipped with a lithium manganese dioxide, a vanadium pentoxide, or an alkaline internal battery or battery pack. There is a danger of explosion and risk of personal injury if the battery is incorrectly replaced or mistreated. Replacement is to be done by an HP authorized service - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 97
. Contact a qualified Taiwanese recycler for proper battery disposal. Power cords The power cord set must meet the requirements for use in the country where have questions about the type of power cord to use, contact an HP authorized service provider. 8-Gb SAN Switch hardware reference manual 97 - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 98
the product. Japanese power cord statement Waste Electrical and Electronic Equipment directive English notice Disposal of waste equipment by users in private households in please contact your local city office, your household waste disposal service, or the shop where you purchased the product. Dutch - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 99
éservation des ressources naturelles et garantit que ces appareils seront recyclés dans le respect de la santé humaine et de l'environnement. Pour obtenir plus 8-Gb SAN Switch hardware reference manual 99 - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 100
d'informations sur les centres de collecte et de recyclage des appareils mis au rebut, veuillez contacter les autorités locales de votre région, les services de collecte des ordures ménagères ou le magasin dans lequel vous avez acheté ce produit. German notice Entsorgung von Altgeräten aus privaten - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 101
, contattare l'ente locale per lo smaltimento dei rifiuti, oppure il negozio presso il quale è stato acquistato il prodotto. Latvian notice Lithuanian notice Polish notice 8-Gb SAN Switch hardware reference manual 101 - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 102
ambiente e a saúde das pessoas. Para obter mais informações sobre locais que reciclam esse tipo de material, entre em contato com o escritório da HP em sua cidade, com o serviço de coleta de lixo ou com a loja em que o produto foi adquirido. Slovakian notice Slovenian notice Spanish notice Eliminaci - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 103
lokala kommunkontor, din närmsta återvinningsstation för hushållsavfall eller affären där du köpte produkten för att få mer information om var du kan lämna ditt avfall för återvinning. 8-Gb SAN Switch hardware reference manual 103 - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 104
104 Regulatory compliance and safety - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 105
, you must follow certain precautions when setting up the system or handling parts. HP authorized reseller install the part. NOTE: For more information on static electricity, or for assistance with product installation, contact your HP authorized reseller. 8-Gb SAN Switch hardware reference manual - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 106
106 Electrostatic discharge - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 107
domain ID, 49 setting the IP address, 48 setting the static IP address, 48 synchronizing local time, 51 verifying the configuration, 52 connecting to fabric, 46 conventions document, 12 text symbols, 12 converged network switch configuring, 56 features, 24 nonport side LED activity, 67 port side LED - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 108
, 13 HP StorageWorks SAN switches 8/40 power pack+, 16 8/80 power pack+, 16 HP StorageWorks SAN switches encryption power pack+, 16 HP StorageWorks SAN switches 8/24, 16 8/40, 16 8/8 base, 16 8/8 full fabric, 16 8/80, 16 encryption, 16 FCoE converged network, 16 power pack+ models, 17 I Installation - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 109
, 97 technical support HP, 13 technical support service locator website, 14 Telnet session opening, 49 text symbols, 12 time zones setting, 51 W warning rack stability, 12 websites customer self repair, 13 HP , 14 HP Subscriber's Choice for Business, 13 product manuals, 11 8-Gb SAN Switch hardware - HP StorageWorks 8/8 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 110
110