- HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 1
HP StorageWorks Fabric OS 6.2.0g release notes Part number: 5697-0355 Third edition: March 2010 - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 2
2010 Brocade Communications Systems, Incorporated Confidential computer software. Valid license from HP HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 3
ICL connectivity to other DC04 and DC SAN Backbone directors • Virtual Fabrics (VF) • Full VF feature support on HP StorageWorks DC SAN Backbone Director, HP StorageWorks DC04 SAN Director, HP StorageWorks 8/80 SAN Switch, and HP StorageWorks 8/40 SAN Switch. • Single physical chassis that can be - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 4
for support with virtual fabrics • Support for HP StorageWorks SAN Director 48 Port 8Gb FC Blade with VF-enabled HP StorageWorks DC SAN Backbone Director and DC04 SAN Director for FICON environments • Access Gateway enhancements • AG mode support on HP StorageWorks 8/40 SAN Switch. • Miscellaneous - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 5
brought forward with Fabric OS 6.2.0g. Virtual fabrics • Virtual Fabrics (VF) is a new capability supported on the HP StorageWorks DC SAN Backbone Director, DC04 SAN Director, HP StorageWorks 8/80 SAN Switch, and HP StorageWorks 8/40 SAN Switch. Once enabled, VF allows the user to divide a single - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 6
8G platforms. • The Integrated Routing license allows ports in an HP StorageWorks DC SAN Backbone Director, HP StorageWorks DC04 SAN Director, HP StorageWorks 8/80 SAN Switch, or HP StorageWorks 8/40 SAN Switch to be configured as EX_Ports, supporting Fibre Channel Routing. This eliminates the need - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 7
products supported by Fabric OS 6.0.x can be upgraded to Fabric OS 6.2.0g. If applicable, HP recommends that you upgrade to Fabric OS 6.2.0g as soon as possible to take advantage of the latest fixes and features. See Firmware upgrades and downgrades for more information. HP StorageWorks Fabric OS - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 8
's Guide before configuring these products in any fabric. Supported product models The following product models can be upgraded to Fabric OS 6.2.0g: • HP StorageWorks 4/8 SAN Switch and 4/16 SAN Switch (Brocade 200E) • HP StorageWorks 4/32 SAN Switch (Brocade 4100) • HP StorageWorks 4/32B SAN Switch - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 9
not supported in the DC SAN Backbone Director or DC04 SAN Director • HP StorageWorks 8/8 and 8/24 SAN Switches (Brocade 300) • HP StorageWorks 8/40 SAN Switch (Brocade 5100) • HP StorageWorks 8/80 SAN Switch (Brocade 5300) • HP StorageWorks 400 Multi-protocol Router (Brocade 7500) • HP StorageWorks - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 10
40 SAN Switch (Brocade 5100) IMPORTANT: Although the HP StorageWorks 4/8 SAN Switch uses the same hardware as the 4/16 SAN Switch, it does not support Access Gateway. The same applies to the HP StorageWorks 8/8 and 8/24 SAN Switches. Both use the same hardware, but only the 8/24, which has all ports - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 11
problems may arise when configuring settings through these older products. NOTE: Do not configure zoning through a switch operating with Fabric OS 3.x in a fabric that has products operating with newer versions of Fabric OS. Prerequisites Table 1 lists the supported Fabric OS firmware versions. HP - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 12
IMPORTANT: The Fabric OS versions listed in the Earliest compatible version column in Table 1 are the earliest versions supported by HP at the time of the Fabric OS 6.2.0g release. 12 - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 13
SAN Switch HP StorageWorks 4/16 SAN Switch HP StorageWorks 4/64 SAN Switch HP StorageWorks B-series MP Router Blade (FR4-18i) HP StorageWorks 16 Port 4-Gb Blade (FC4-16) HP StorageWorks 32 Port 4-Gb Blade (FC4-32) HP StorageWorks 400 MP Router HP StorageWorks 4/32 SAN Switch 5.3.1a 6.2.0g Brocade - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 14
or later can result in problems with Zoning, Performance monitoring, SYSLOG configuration, FICON wizards, IOD Delay, AAA replication, Port enable/disable and other functions. Unless you are using Admin Domains, HP recommends that you upgrade to HP StorageWorks Data Center Fabric Manager (DCFM) 10 - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 15
. The DC04 SAN Director requires Fabric OS 6.2.0a or later, and supports up to four blades. FS8-18 (DC Switch Encryption FC blade) Supported with Fabric OS 6.2.0b or later, with a maximum of four blades of this type on the DC SAN Backbone Director or DC04 SAN Director HP StorageWorks Fabric OS - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 16
with nominal power of 110 VAC. See the appropriate hardware reference guide for power specifications. Fibre Channel Routing scalability For the latest Fibre Channel Routing (FCR) scalability support information, see the HP StorageWorks SAN design reference guide, available at: http://www.hp.com/go - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 17
and scalability (24 physical fabrics, up to 9,000 switch ports). DCFM Enterprise configures and manages DC SAN Backbone Directors, along with other B-series directors, routers, switches, and HBAs. Existing EFCM and FM customers that have active Maintenance and Support contracts are provided - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 18
modes for deployment with M-EOS-based products. All HP StorageWorks models supported by Fabric OS 6.2.0g support both interopmodes 2 and 3, with the exception of the 4/32 SAN Switch. NOTE: HP may not support all of these switches in this mode. See "Merging Fabrics based on M-series and B-series FC - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 19
Switch Port Mirroring Extended Fabrics Alias Server Platform Service FCIP (VE_Ports) IPFC (IP over FC) M-EOS ALPA 0x13 configuration VE to VEX Port Integrated Routing4 Domain Offset Support 239 Domain Support Yes12 Yes Yes Yes No Yes13 Yes Yes Yes HP StorageWorks Fabric OS 6.2.0g release notes 19 - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 20
OS 6.2.0g on the following platforms: • Brocade 4Gb SAN Switch for HP p-Class BladeSystem • Brocade 4Gb SAN Switch for HP c-Class BladeSystem • HP StorageWorks SAN Switch 4/32 • HP StorageWorks 4/8 and 4/16 SAN Switches When upgrading to Fabric OS 6.2.0g from Fabric OS 6.1.0g or earlier, the CPs do - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 21
. For routed SANs with M-EOS switches in an edge fabric, upgrades to Fabric OS 6.2.0g are non-disruptive if all EX_Ports to M-EOS edge fabrics are attached to 4/256 SAN Directors with an MP router blade (FR4-18i). Firmware upgrade instructions IMPORTANT: HP recommends that users upgrade to Fabric OS - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 22
FIDs match for all switches in the same Logical Fabric. • The aptpolicy can be configured per logical switch. The Administrator Guide indicates it is a chassis-level setting. • In order to support non-disruptive Hot Code Load on an HP StorageWorks 8/40 SAN Switch with VF enabled, the total zoning DB - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 23
the upgrade. Adaptive networking/flow-based QoS prioritization • When using QoS in a fabric with 4-Gb ports or switches, Fabric OS 6.0 or later must be installed on all products in order to pass QoS info. E_Ports from the HP StorageWorks DC SAN Backbone Director or HP StorageWorks DC04 SAN Director - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 24
Fabric OS 6.1 or later. • The HP StorageWorks 8/40 SAN Switch does not support Hot Code Load from Fabric OS 6.1.0 to 6.2.x in a dual backbone configuration with a routed connection to an M-EOS product. • Integrated Routing EX_Ports are supported only in the base switch on a switch with VF enabled - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 25
blade now supports the attachment of loop devices in the HP StorageWorks DC SAN Director and HP StorageWorks DC04 SAN Director. • Virtual Fabrics must be enabled on the chassis and loop devices may only be attached to ports on a 48-port blade assigned to a non-Default Logical Switch operating with - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 26
By default vc_init is enabled. When vc_init is enabled, the long distance link uses ARB primitives. When vc_init is disabled, the link uses IDLE primitives. The buffer-to-buffer credit recovery feature is not supported on Extended Fabrics E_Port when it is configured to use IDLE primitives. The user - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 27
to non 8-Gb FC ports. This command disables and re-enables the port and the port comes online with the new fill word setting. The configuration is stored in nonvolatile memory and is persistent across switch reboots or power cycle. To display user-configured fill word settings, use the portCfgShow - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 28
of FOS v6.2.0d, the new command defaulted to mode 0 (Idle) and enabled the user to configure the ARB configuration. • Existing Product: This change has no effect on current product configurations in the field. The mode is currently 0, and during a firmware upgrade the mode remains 0 and no devices - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 29
created. You will now see the following revised message: nl Logical Switch has been created with default configurations. Please configure the Logical Switch with appropriate switch and protocol settings before activating the Logical Switch. HP StorageWorks Fabric OS 6.2.0g release notes 29 - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 30
are selected. Fabric events Fabric summary Monitor > Fabric events Monitor > Logs > Events Monitor > Reports > Fabric Reports > Fabric summary Summary report FCIP tunnel configuration Port Admin Module > GigE tab Configure > FCIP tunnel Viewing FCIP tunnels is still supported in Web Tools - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 31
be in an Encryption Enabled state before committing additional LUN modifications. • Avoid changing the configuration of any LUN that belongs to a Crypto Target Container/LUN configuration while the re-keying process for that LUN is active. If the user changes the LUN's settings during manual or auto - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 32
before any Re-Key, First Time Encryption, or enabling EE for crypto operations. Failure to do so results in HA Cluster creation failure. If the IP address for these ports is configured after the EE was enabled for encryption, HP Encryption Switch needs to be rebooted and Encryption blades should be - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 33
after the power-cycle. This condition persists until the GL node is back online. • Workaround. In the case of a datacenter power down, MSA configuration, for example). • For HP-UX, LUN0 can appear as 0x0 or 0x400, but both of them are LUN0 only, and should be treated alike. HP StorageWorks Fabric OS - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 34
prior to upgrade: Check the domain ID before adding a switch to any fabric. USB port LED of HP StorageWorks DC SAN Backbone Director CP blade stays ON after HA failover. CUP Port stuck in Contingent Allegiance State after z9 Host IPL. Spinfab and porttest (diagnostics) are not supported on ICL - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 35
HCL on an HP StorageWorks 8/40 SAN switch in Interop Mode requires the use of the -o option. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Use the -o option. A turboramtest failure does not fully disable the port on an HP StorageWorks 8/80 SAN switch. Fixed in Fabric OS 6.2.0. Workaround - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 36
default zone and the user tries cfgenablecfg- Fixed in Fabric OS 6.2.0. disable. When disabling/enabling a port, port fencing disables the port because the allowable number of invalid transmission words is exceeded. Fixed in Fabric OS 6.2.0. Ag --show on an HP StorageWorks 8/8 or 8/24 SAN Switch - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 37
OS 6.2.0. Warnings of excessively high temperature seen on some HP StorageWorks 8/40 SAN switches. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Increase cooling or relocate switch to cooler location. Be sure switch is installed with proper spacing above and below it. POST (portloopback - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 38
edge HP StorageWorks DC SAN Backbone Director in fabric. Fixed in Fabric OS 6.2.0. The portcfgnpivport CLI command will not toggle trunked slave ports if the user disables NPIV configuration on that port. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: The user must manually toggle (enable - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 39
shows None for the In Port field on HP StorageWorks 8/8, 8/24, and 8/40 SAN Switches. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Use urouteshow to view the 'Out Port' selected for a particular 'In Port' to a domain when using Port Based Routing. HCL on switch continues if sent Pause - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 40
. On an HP StorageWorks 8/80 SAN Switch, the system status LED does not flash amber/green when a power supply is faulted. Fixed in Fabric OS 6.2.0. User with admin role in some AD is able to add another user with admin role in AD as ALL. Fixed in Fabric OS 6.2.0. Reset to default button is - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 41
data for HP StorageWorks 8/40 and 8/80 SAN switches. Fixed in Fabric OS 6.2.0. Portcfgspeed command on 8G FC platforms are accepting invalid port speed = 5. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Do not provide a value of 5 to the portcfgspeed command. Speed will be set to 8. If - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 42
in Fabric OS 6.2.0. HP StorageWorks DC SAN Backbone Director blades fault after resetting a server with 32 HBAs. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Power cycle the slot. Set port speed to anything other than autonegotiate. Fast Write configuration not properly installed after - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 43
of uwatt to dbm for GE ports Tx Rx values shown in Web Tools are incorrect. Fixed in Fabric OS 6.2.0. HP StorageWorks 8/40 SAN Switch: FRU faulty status is not recovered correctly. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Turn on the power switch as soon as possible after inserting - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 44
offline/online.1 Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: switchdisable/enable of the 400 MP router allows the devices to see each other CRC error observed between HP StorageWorks 8/40 and 8/80 SAN switches with a particular SFP type. Fixed in Fabric OS 6.2.0. Fibre Channel Fast - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 45
interrupt handling problem. Fixed in Fabric OS 6.2.0b. Unable to configure ports using configdownload if the ports are not physically present in the director (blade not plugged in). Fixed in Fabric OS 6.2.0b. On HP StorageWorks DC SAN Director, after running fosconfig --enable vf, followed - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 46
Mode check from Edit CUP Port Connectivity configuration window. Fixed in Fabric OS 6.2.0b. c-Class Onboard Administrator is unable to read the switchname for Brocade 8Gb SAN Switch for HP BladeSystem c-Class. Workaround prior to upgrade: The switch name can be displayed from Fabric OS CLI command - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 47
0c FICON XRC times out on a 400 MP Router to an HP DC SAN Director, Fixed in Fabric OS 6.2.0c which causes drives not to come online. Need support in Fabric OS for DWDM-SFP media. Enabled new SFP support in Fabric OS 6.2.0c HP StorageWorks 8/40 SAN Switch did not indicate a warning when Fixed in - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 48
USM configuration sets. Detected termination of 0.weblinker.fcg on HP StorageWorks DC04 SAN Director and messages like KSWD-1002, 5766, SLOT Fixed in Fabric OS 6.2.0d 4 | FFDC | CHASSIS, WARNING displayed on the console. After enabling Virtual Fabric via DCFM on HP StorageWorks 8/40 SAN Switch - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 49
to tape I/O failure/errors. The host detects IFCC errors to CUP port. Fixed in Fabric OS 6.2.0d HP StorageWorks Encryption SAN Switch went faulty when starting traffic, which let to loss of LUNs to the host. Fixed in Fabric OS 6.2.0d Taking SKM down while rekeys are in progress causes a LUN - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 50
Fixed in Fabric OS 6.2.0d OS switch is used as seed switch. HP StorageWorks 8/24 SAN Switch is not responding to Link Reset primitives correctly (may send OLS and/or Link Reset). Fixed in Fabric OS 6.2.0d Rekey operations get stuck and progress halts. Fixed in Fabric OS 6.2.0d User sees a name - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 51
on a switch that has been upgraded from a lower code level to Fabric OS 6.1.2 and never cold booted. No errors will be caused on enabled ports, or after a disabled port is enabled. Fixed in Fabric OS 6.2.0e When a blade is hot plugged into an HP StorageWorks DC SAN Director or HP StorageWorks DC04 - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 52
executed without enabling those ports. Fixed in Fabric OS 6.2.0f Fabric OS 6.2.0g fixes The following table lists defects closed in the Fabric OS 6.2.0g firmware release. Table 15 Fabric OS 6.2.0g closed defects Closed defect summary Solution An HP StorageWorks Encryption SAN Switch goes into - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 53
persistently disabled. Fixed in Fabric OS 6.2.0g A passive path LUN gets stuck in the Not Ready (Getting key from archive) state when running a test that periodically breaks the Ethernet connection to the primary key vault. Fixed in Fabric OS 6.2.0g HP StorageWorks Fabric OS 6.2.0g release notes - HP StorageWorks 8/8 | HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355, - Page 54